Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Multislice CT made simple

Philips MX 4000 Dual


Philips MX systems bring new levels of Reasons to choose MX 4000 Dual
quality, simplicity and reliability to CT • Simple, reliable operation to manage heavy
patient loads
imaging. Designed by the same people that
• 0.8** sec rotation minimizes motion; 0.9** sec
brought the world Philips CT, the MX 4000 reconstruction for productivity; 0.8** mm slices
Dual* configuration combines the for sharp inner ears and bones
• 20mm coverage for faster exams and
enhanced diagnostic benefits of multislice
shorter breathholds
imaging and high throughput performance • Easy-to-use interface offers advanced capabilities
in one extremely versatile system. • Patient-friendly, compact design by the award-
winning Philips Design team
• A wide range of clinical applications helps you • DoseWise design delivers optimal dose efficiency
conduct accurate studies over diverse patient without compromising image quality
populations • Philips Customer Care offers global parts and
• Simple ease of use translates into higher produc- service network for unsurpassed uptime
tivity and a more enjoyable work environment • Brilliance Extended Workspace** provides
• Advanced technologies provide the power advanced applications environment designed
necessary for clearer diagnoses, faster exams and exclusively for multislice CT
higher reliability *Not available for sale in all countries. **optional
Contents

3 Multislice RSVP 8 Reconstruction and Display


Reconstruction Modes
4 Patient Handling and Setup TrueLook Imaging
Gantry
Table 9 Post-Processing and Communication
Table Accessories Image Processing
Scan Planning Image Graphics
Window Control
6 Scan and Image Acquisition Host Computer
System Monitor
Generator
X-ray Tube 10 Analysis Tools
Detector Included
Image Quality Optional
Scanning Modes
Scan Times 12 Effective Data Management
Test Injection Bolus Timing Archiving
Filming
7 Dose Management Networking
Smart Beam Management DICOM
More Dosage Awarenesss
13 Site Planning

2
Multislice RSVP

The MX 4000 Dual multislice technology is best


summarized using the acronym R.S.V.P. for double, the
performance compared to single slice CT systems.

Single-slice scanner MX 4000 Dual Advantage

• Early detection of
double Resolution small lesions
same Speed
same Volume
same Power
R • Eliminates need for
coronal scans
• Improves sagital and
coronal reformation
10mm collimation 2 x 5mm collimation

same Resolution • Single breathold


double Speed
same Volume
same Power
S acquisitions
• Decreased dose
• New applications:
CTA
68 sec acquisition 34 sec acquisition

same Resolution
same Speed
double Volume
same Power
V • Trauma triage
• New applications:
Vascular run-off

60mm coverage 120mm coverage

same Resolution • Ideal for large


same Speed
same Volume
double Power
P patients and
hard to image areas

100 mAs 200 mAs

3
Patient Handling and Setup

Flexible Patient Handling AutoVoice


The friendly and advanced design of MX 4000 Dual A standard set of commands for patient communica-
delivers optimal patient comfort and control. tion; before, during and after scanning.
Also provides the ability to record customized
Gantry messages.
Scan Control Panels
Controls and displays for gantry tilt, patient couch Intercom System
elevation and stroke are located on both sides of the Two-way intercom allows patient monitoring and
gantry. communication.
Scan Control Box
Gantry and patient couch controls and displays are Table
located conveniently at the operator’s console. Longitudinal motion:
Additional functions include emergency stop, Stroke: 1600mm
intercom, and scan enable/pause buttons. Scannable range: 1500mm
(with head holder)
Gantry Aperture: 700mm diameter Speed: up to 100mm/s
Gantry tilt: -30° to +30° Position accuracy: ±0.25mm
Vertical motion:
Slice Position Indicator: Range: 430-970mm;
• Internal slice plane laser marker 1.0mm increments
Speed: 9-41mm/s
X-Ray Indicator Table load capacity:
On scan control panels and inside the gantry. 200 kg (440 lb) with full accuracy
Floating tabletop
Carbon-fiber table top with hand control for easy
positioning and quick release.

4
Table Accessories • Multi-protocol with timing allows the user to easily
From extra padding to optimal support, our table and precisely program acquisitions of varying slice
accessories prevent fatigue and discomfort and give thickness, breathing or scan delay pauses, and table
both patients and technologists a sense of security. speeds. Efficient planning of any exam, complex or
routine, decreases exam times, increasing throughput
and patient satisfaction.
Standard Accessories

Surview Plan
Planning via interactive mouse control of multiple, inde-
pendent acquisition series of any type on the Surview
image.
Knee Rest Patient Pads Viewing angles: 90°, 180°
Longitudinal speed: 100mm/sec
Scan length: 100mm, 300mm,
500mm, 1000mm
Scan width: 500mm

Automatic Scan
Head Holder Table Pad (Not shown) Enables automatic execution of pre-planned studies,
with concurrent, on-line or off-line reconstruction,
Easy Patient Setup background image archiving to local or remote storage
The MX 4000 Dual system has its own set of devices without operator intervention.
innovative features for departmental efficiency,
using scan planning and easy protocol development. DICOM® Modality Worklist*
Provides HIS/RIS interface through DICOM modality
Scan Planning worklist service class; enhances clinical workflow by
Registration of patient information and clinical importing patient demographics and study information
procedure selection, using anatomic graphical from an information management system.
display and sample images.
User Interface
Expert Protocol Planning The entire MX user interface is available in either
Flexible selection of protocol parameters for English or Chinese. Patient name and demographics may
optimized scanning. Allows users to tailor be entered in English, Chinese or with any characters
protocols to their specific needs. included in Latin I.

• Pre-defined and user programmable scan protocols,


including multi-protocol procedures, can be stored
and retrieved. Scan parameters may be easily modified
before and during the study to meet specific clinical
needs.

5
*optional
Scan and Image Acquisition

Maximized System Performance Image Quality


Reliable, maximized system performance allows clini- Spatial Resolution:
cians to remain focused on patient care.The MX 4000 High mode: 15.0Lp/cm @ cut-off
Dual is perfectly balanced, combining power and flexibili- Noise:
ty to maximize image quality, speed and throughput. 0.35% as measured on the 8.5in (21.6cm) AAPM
Low Contrast Resolution:
System 3.0mm @ 0.5% as measured on the 8.5in (21.6cm)
Rotate-rotate architecture with optimized geometry for AAPM phantom
low dose imaging. Absorption Range:
-1024 to +3072 Hounsfield units
Generator
The MX 4000 Dual generator uses modern, low-voltage Scanning Modes
slip ring technology to provide a constant high voltage Spiral Scanning
to the CT X-ray tube assembly. • Multiple contiguous slices acquired simultaneously with
kV: 80, 100, 120, 140kVp continuous table movement during scans
Output capacity: mA: 28kw 30-200mA • Multiple, bi-directional acquisitions
Spiral exposure: Up to 80 seconds
X-ray Tube Spiral pitch: 0.5 to 2.0 and user selectable
Rotating graphite composite anode; continuous Axial Scanning
operation during scan. • Multiple-slice scan with up to two contiguous slices
Anode Max Storage Capacity: acquired simultaneously with incremental table move-
2.5MHU ment between scans
Anode Max Cooling Rate: 423kHu/min • Fused modes for reconstructing partial volume arti-
Focal spot (IEC): fact-free thick slices from thin slice acquisition
Large: 0.6mm x 1.3mm
Small: 0.4mm x 0.7mm Scan Times
Focus-detector distance: 1318mm 0.8*, 1, 1.5, 2, 2.5, 3 seconds for full 360° scans
Focus-isocenter distance: 618mm 0.53* seconds for partial angle 240° scans
0.8 Second Rotation*
Detector 0.8-second 360° rotation speed (up to 2.5 slices per
Philips Medical Systems multislice detector design second) provides better temporal resolution in
acquires high quality images while minimizing patient advanced clinical applications for high-speed, motion-
dose. free imaging.
Material: GOS
No. of Elements: 1,440
Dynamic Range: 1,000,000 to 1
Data Sampling Rate:
Up to 1024 views/revolution/element
Slice Collimation: 2 x 0.8*, 2 x 1.0, 2 x 2.5,
2 x 5.0, 2 x 7.0,
2 x 10.0mm in dual
slice mode
Scan Angles: 240°, 360°
Scan Field of View: 250, 500mm

6
*optional based upon configuration
Dose Management

Smart Beam Management


In Philips multislice CT scanners, specific Smart Beam
Management innovations have been developed to block
out X-rays that do not contribute to image quality.
Through the use of IntelliBeam™ filtration, dose can be
managed to limit the exposure specifically to the loca-
tion of interest.

More Dosage Awareness


Dose displays include:
• CTDI Volume
• Dose Efficiency

Dedicated Pediatric Protocols


Age and weight-specific protocols, developed using a
dedicated pediatric and weight specific dose phantom,
provide dedicated low-dose techniques (as low as 30
mAs) to optimize image quality. Combined with the new
Dose Display features, MX customers have an easy,
accurate method for controlling the dose their young
patients receive.

• Infant (0-24 months)


• Pediatric (2-15 years)

7
Reconstruction and Display

Rapid Reconstruction Filters: Choice of ten different filters.


Fast reconstruction is vitally important when rapid Zoom & Pan: Real-time, mouse-controlled
imaging and viewing is a priority. For example, during with magnification. Can be
trauma scanning, it is important for the technologist redefined during the study.
and/or radiologist to identify any serious injury quickly. Archive: On-line image archiving to
any installed storage device,
Reconstruction Rate and PACS*.
2
Up to 0.9* seconds/image using 512 matrix.
Quality imaging
Reconstruction Field of View: One high tech component or piece of software is not
50 to 500mm continuous enough to deliver a fine CT image. Outstanding clinical
results depend on a fine tuned, balanced imaging chain –
Reconstruction Modes from X-ray tube to detector to display. Philips engineers
Concurrent Reconstruction and physicists have incorporated the right technologies
Image reconstruction in line with acquisition. in MX CT by including a stable x-ray tube proven in
over 2000 installations, anti-scatter grid, Philips CT
Off-Line Reconstruction reconstruction algorithms and filters and more. As a
Off-Line (batch) background image reconstruction of result MX CT creates images that look more like actual
user-defined groups of raw data files anatomy.
with automatic image storage.
UltraImage
Add Reconstruction UltraImage includes proprietary pre- and
Enables quick and easy unplanned or modified recon- postprocessing hardware and software for enhanced
structions of part or all of the images prospectively visualization of soft tissue structures. UltraImage signifi-
planned. cantly improves image quality for the most accurate
representation of even the most difficult to image
Reconstruction Parameters anatomic areas.The full clinical impact of UltraImage is
Any study can be set up to automatically reconstruct best appreciated in the brain, long bones, spine, pelvis or
using various reconstruction parameters. Exams can be shoulder, where subtle, soft tissue structures can be
tailored online while planning the scan, or during off-line obscured by adjacent high contrast bone.
recon. Up to six different reconstruction assignments
are possible for each study. Image reconstruction
parameters include:

8
*optional based upon configuration
Post-Processing and Communication

Philips MX 4000 Dual combines a high- performance Window Control


workstation and scanner into one convenient, powerful, • Eight user-defined preset windows provide fast
and cost-effective multislice CT system. and convenient window setting. Mouse-driven fine
adjustments of the window center and width enable
Image Processing optimal image viewing.
The interactive image viewer is designed for fast, effi-
cient and simple image review and filming Host Computer
purposes. Images can be handled individually or in user- Computer Architecture:
selected groups. • Microsoft Windows
• Dual Intel Xeon™ CPU
• Image viewer window: Displays a single image
or a selection of images. Main Memory:
• Zoom & Pan: Magnification from 0.8 to 10 times. 2.0 GB RAM
• Scroll Bar, Leaf & Cine, Invert Image,
Image Parameters Display. Monitor
19 inch, 1,280 x 1,024 Flat Panel LCD
Image Graphics
To help interpret clinical images, a variety of text
and graphic aids may be individually positioned and
manipulated with the mouse:
• Text annotations.
• Cursors for pixel value measurements.
• Regions of interest (ROI)—elliptical, rectangular, with
instantaneous calculation and display of area, average
pixel value and standard deviation.
• Lines, grid and scales for distance measurements, and
for measuring any shape.
• Arrows for pointing to features.
• Angle measurements.
• Profile of pixel values along any line.
• Grid with adjustable spacing for distance assessment.

9
Analysis Tools

Included

MPR- Multiplanar Maximum or Minimum 3-D SSD Reconstruction Volume Rendering


Reformation Intensity Projection (MIP) Provides fast reconstruction of 3-D visualization software
Real-time reformation of axial CT and MR Angiography three-dimensional images of up provides unique simultaneous
images into any user-defined Maximum Intensity Projection to 15 different tissues or organs visualization of vasculature, soft
plane - coronal, sagittal or general (MIP) images, from a volumetric and easy to understand tissue and bone. Unlike
oblique – or curved plane. set of images, can be quickly presentation of complex anatomy. conventional 3-D or MIP, volume
Interactive and friendly user inter- reconstructed to demonstrate Real-time manipulation of 3-D rendering visualization offers real
face is provided.The user defines enhanced vascular structures.The images includes zoom, pan, time interactive control over
the number of planes, their posi- projection images can be interac- rotation around any axis, and opacity and transparency values
tion, orientation, thickness and tively generated in any arbitrary cutting of the organs with a to permit viewing through and
spacing and the reformatted viewing angle, and can be win- user-defined viewing aperture to beyond surrounding structures,
image is displayed in real-time. dowed, zoomed and panned. expose underlying tissues. such as metallic stents and
Zoom, pan, leaf and window are Making a tissue transparent arterial calcifications.
available. enables viewing of underlying
organs.

Curved MPR Pediatric Protocols


Defines MPR curved cuts along Age and weight specific pediatric
vascular structures on MIP or protocols insure children are scanned
volume-rendered images for with peak image quality without
panoramic and cross-sectional excess radiation dose.
views.

10
Optional

Bone Mineral Analysis Virtual Endoscopy Extended Brilliance Workspace


The Bone Mineral Analysis package Renders spiral CT data to Extended Brilliance Workspace is a
is an independent, PC-based data provide fly-through images within flexible and friendly CT workstation
analysis system for measuring and around hollow organs. rich in applications and scalable to
bone mineral density to monitor Clinical applications include your needs. It includes a set of the
metabolic bone disease, such as virtual colonoscopy, bron- most powerful CT capabilities on
osteoporosis. It uses a patented choscopy, and angioscopy. the market today, improving out-
histogram-based method to comes and productivity by working
accurately measure only trabecular the way you do. Nearly all
bone without the need for an visualization advanced CT applications
external calibration phantom. and archiving can be done quickly
and easily.

11
Effective Data Management

The MX 4000 Dual operating system provides a user- Networking


friendly interface and the performance and archiving Network connections should be located within
capabilities necessary to effectively manage multislice 10 feet of the console. MX 4000 Dual supports
datasets. 10/100Mbps network speeds. For optimal
performance, Philips recommends 100Mbps
Archiving network speed and that the CT network be
Image archiving is organized according to the DICOM segmented from the rest of the hospital network.
3.0 hierarchical model, in a DICOM 3.0 compliant image
format. Loss-less image compression/decompression DICOM
algorithm is used during image storage/retrieval to/from The DICOM 3.0 communications protocol allows
all local archives. Images can be auto-archived to select- connectivity to DICOM 3.0 compliant scanners,
ed archive media. workstations, and printers; supports IHE requirements
for DICOM connectivity.

MX 4000 Dual includes the following DICOM


Type Hard Drive CD/RW
functionality:
Capacity 160GB 700MB • Service Class User & Provider
• DICOM Print
Images1 300,000 1228
• Modality Worklist*
Exams2 10,000 4
Reporting*
1
512 x 512 Matrix Uncompressed
2
Based on 30 images per study Users can create and distribute comprehensive
one-page reports of key results and findings.
The reports contain text and images; custom tem-
CD Writer plates can be created and saved for future use.
CD Writer is a compact disk (CD) drive that stores
DICOM images along with viewing software on CD
media. CD Writer provides a low cost and flexible
alternative for archiving images and for providing images
to referring physicians—useful for presentations and
teaching files or patients.

Filming
This function allows the user to set up and store filming
parameters. Pre-stored protocols can be set to include
auto-filming, multiformat that saves film.The operator
can film immediately after each image, at the end of a
series, or film after the end of a study and review
images prior to print.The operator can also automati-
cally film the study at three different windows and
incorporate Combine Images functionality to manage
large datasets. Basic monochrome and color DICOM
print capability are supported.

12
*optional based upon configuration
Site Planning MX 4000

Contact the Philips Site Planning department for specific Environmental Requirements
requirements pertaining to optional imaging/viewing equipment floor Temperature:
space and electrical, mechanical, structural or environmental specifi- Gantry room: 20° to 24° C (68° to 75° F)
cations. Control room: 18° to 28° C (64° to 82° F)
Storage/Transport: -20° to +50° C (-4 ° F to 122° F)
Power Requirements MX 4000
• 380 VAC, 50/60 Hz, 38 kVA max. to CT scanner Humidity:
• 200/208/220/230/240/380/400/415/440/460/480 VAC Gantry/Room: 30% to 60% non-condensing
with line match transformer Storage/Transport: 10% to 90% non-condensing
• 3-phase distribution source
Minimum Ceiling Height:
Console Uninterrupted Power Supply (UPS)* 230cm (90.6”)
Provides up to 10 minutes of backup power for host
computer, reconstruction, and monitor.

Dimensions and weights

weight height width depth

gantry 1700 kg (3740 lb) 189cm (75˝) 221cm (87˝) 85cm (34˝)
patient table 400 kg (880 lb) 64cm (25˝) 244cm (96˝) 57.5cm (23˝)
console table/CPU 102 kg (224 lb) 75.5cm (30˝) 144cm (55˝) 70cm (28˝)

13
Philips: Partnering with You

Worldwide, Philips Medical Systems is the proven leader Service


in clinical solutions.With its dedication in imaging, Choose a Philips CUSTOMerCARE service
patient monitoring and home health care, Philips pro- agreement for your medical equipment and take
vides its physicians and patients with the least invasive advantage of the power of choice to optimize your
and most reliable solution to meet their needs. As your clinical and financial results.We'll tailor a service
partner in CT, Philips strives to support your practice agreement to match your specific needs.Through
with versatile solutions and the highest level of product service excellence, flexible solutions and effective
and service.Together, we are changing the practice of relationships, we give you the support you need
medicine today, and redefining the clinical successes of to succeed in today's complex healthcare environment.
tomorrow. Maximize and protect your investment with a Philips
CUSTOMerCARE Service Agreement.
Research
Since pioneering the first-ever multislice CT • Improve productivity
scanner more than a dozen years ago, Philips has been a • Lower cost of ownership
visionary in its approach to innovative, advanced CT • Increase equipment uptime
applications.The advent of this advanced detector tech- • Maintain peak clinical performance
nology is just another example of Philips making
advanced applications routine and helping you deliver
clinical excellence without compromise.

14
15
Philips Medical Systems is part of
Royal Philips Electronics

Interested?
Would you like to know more about our imaginative
products? Please do not hesitate to contact us.We would
be glad to hear from you.

On the web
www.medical.philips.com

Via email
medical@philips.com

By fax
+31 40 27 64 887

By mail
Philips Medical Systems
Global Information Center
P.O. Box 1286
5602 BG Eindhoven
The Netherlands

By phone
Asia
Tel: +852 2821 5888

Europe, Middle East, Africa


Tel: +49 7031 463 2254

Latin America
Tel: +55 11 2125 0764

North America
Tel: +1 800 299 6417

© 2007 Koninklijke Philips Electronics N.V.


All rights are reserved.

Philips Medical Systems Nederland B.V. reserves the right to make changes in specifications and/or to discontinue any product at any time without notice
or obligation and will not be liable for any consequences resulting from the use of this publication.

Printed in The Netherlands.


4522 962 05241/728 * NOV 2007