Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Technical specification

Dewatering pump BS 2660, 60 Hz


BS 2660

Cable
SUBCAB® AWG 4AWG/3-2-1-GC
6AWG/3-2-1-GC
8AWG/3-2-1-GC
8AWG/4
10AWG/3-2-1-GC
10AWG/4
12AWG/4
12AWG/7
14AWG/4
14AWG/7

Monitoring equipment
Thermal contacts opening temp. +140°C

Material
Impeller High chrome alloyed white cast iron

BS 2660 Wear parts


Stator housing
Strainer
Nitrile rubber, high chrome cast iron
Aluminium
Stainless steel
Shaft Stainless steel
Product O-rings Nitrile rubber
Submersible pump for dewatering building yards, draining water in
flooded areas, and other similar applications. Mechanical face seals
Alternative Inner seal Outer seal
Denomination 1 Corrosion resistant Corrosion resistant
cemented carbide/ cemented carbide/
Product code 2660.180
Corrosion resistant Corrosion resistant
Installation S cemented carbide cemented carbide
Impeller characteristics MT, HT
Surface Treatment
No surface treatment
Process data
Liquid temperature max +40 °C Weight
Depth of immersion max 20 m Excl. cable 78 kg
Liquid density max 1100 kg/m3
Strainer hole size 18 mm x 9 mm Option
The pH of the pumped liquid ph 5 - 8
Warm liquid version

Motor data Starters


Quick couplings
Frequency 60 Hz Zinc anodes
Insulation class H (+180 °C)
Voltage variation Accessories
- continuously running max ± 5%
Adapters, hose connections and other mechanical accessories.
- intermittent running max ± 10%
Electrical accessories such as pump controller, control panels,
Voltage imbalance between phases max 2% monitoring relays, cables.
No. of starts/hour max 30 See separate booklet or www.flygt.com, for further information.

3
BS 2660

MT- Motor rating and performance


curve
2660.180 P2 [hp] / [kW]
20

Ex proof version available


12
15
Rated Power, kW (hp)

Power factor cos ϕ


228
Starting current, A

8
Curve/Impeller No

10
Rated current, A

5 4

0 0
H [ft] / [m]

200 V D, 60 Hz, 3~, 3455 r/min 120 MT


228 11.2 (15) 40 250 0.92 No 35
208 V D, 60 Hz, 3~, 3465 r/min 100 30
228 11.2 (15) 39 262 0.90 No
220 V D, 60 Hz, 3~, 3450 r/min 25
80
228 11.2 (15) 37 222 0.93 No
220 V Y//, 60 Hz, 3~, 3450 r/min 20
60
228 11.2 (15) 37 213 0.92 No
15
230 V D, 60 Hz, 3~, 3465 r/min
40
228 11.2 (15) 35 233 0.91 No 10
230 V Y//, 60 Hz, 3~, 3465 r/min
20
228 11.2 (15) 35 224 0.91 No 5 228
240 V D, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 35 245 0.88 No 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60
240 V Y//, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 35 235 0.88 No 0 100 200 300 400 500 600 700 800 900
380 V D, 60 Hz, 3~, 3450 r/min Q [l/s] / [usgpm]
228 11.2 (15) 21 128 0.93 No
400 V D, 60 Hz, 3~, 3465 r/min
228 11.2 (15) 20 136 0.90 No
440 V D, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 19 129 0.89 No
440 V Yser, 60 Hz, 3~, 3450 r/min
228 11.2 (15) 18 107 0.92 No
460 V D, 60 Hz, 3~, 3455 r/min
228 11.2 (15) 17 110 0.92 No
460 V Yser, 60 Hz, 3~, 3465 r/min
228 11.2 (15) 18 112 0.91 No
480 V D, 60 Hz, 3~, 3470 r/min
228 11.2 (15) 17 115 0.90 No
480 V Yser, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 17 117 0.88 No
575 V D, 60 Hz, 3~, 3470 r/min
228 11.2 (15) 14 96 0.90 No
600 V D, 60 Hz, 3~, 3480 r/min
228 11.2 (15) 14 101 0.87 No
Y/D starting current is approximately 1/3 of D starting current.

4
BS 2660

HT- Motor rating and performance


curve
2660.180 P2 [hp] / [kW]
20

Ex proof version available


12
15
Rated Power, kW (hp)

253

Power factor cos ϕ


Starting current, A
Curve/Impeller No

10 8
Rated current, A

5 4

0 0
H [ft] / [m]

200 V D, 60 Hz, 3~, 3455 r/min HT


228 11.2 (15) 40 250 0.92 No 200 60
208 V D, 60 Hz, 3~, 3465 r/min
228 11.2 (15) 39 262 0.90 No 160 50
220 V D, 60 Hz, 3~, 3450 r/min
228 11.2 (15) 37 222 0.93 No 40
120
220 V Y//, 60 Hz, 3~, 3450 r/min
228 11.2 (15) 37 213 0.92 No 30
230 V D, 60 Hz, 3~, 3465 r/min 80
228 11.2 (15) 35 233 0.91 No 20
230 V Y//, 60 Hz, 3~, 3465 r/min
40 253
228 11.2 (15) 35 224 0.91 No 10
240 V D, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 35 245 0.88 No 0 0
0 5 10 15 20 25 30 35
240 V Y//, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 35 235 0.88 No 0 50 100 150 200 250 300 350 400 450 500 550
380 V D, 60 Hz, 3~, 3450 r/min Q [l/s] / [usgpm]
228 11.2 (15) 21 128 0.93 No
400 V D, 60 Hz, 3~, 3465 r/min
228 11.2 (15) 20 136 0.90 No
440 V D, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 19 129 0.89 No
440 V Yser, 60 Hz, 3~, 3450 r/min
228 11.2 (15) 18 107 0.92 No
460 V D, 60 Hz, 3~, 3455 r/min
228 11.2 (15) 17 110 0.92 No
460 V Yser, 60 Hz, 3~, 3465 r/min
228 11.2 (15) 18 112 0.91 No
480 V D, 60 Hz, 3~, 3470 r/min
228 11.2 (15) 17 115 0.90 No
480 V Yser, 60 Hz, 3~, 3475 r/min
228 11.2 (15) 17 117 0.88 No
575 V D, 60 Hz, 3~, 3470 r/min
228 11.2 (15) 14 96 0.90 No
600 V D, 60 Hz, 3~, 3480 r/min
228 11.2 (15) 14 101 0.87 No
Y/D starting current is approximately 1/3 of D starting current.

5
BS 2660

Dimensional drawing
All drawings are available as Acrobat documents (.pdf)
and AutoCad drawings (.dwg). Download the drawings
from www.flygt.com or contact your ITT Flygt
representative for more information.
All dimensions are in mm (inch).
MT, HT, S-installation
799 - 853 (31.5 - 33.6)

803 (31.6)
712 (28.0)
(5.4)
137

Ø346 (13.6)

6
BS 2660

7
www.flygt.com
BS2660.60Hz.04.EN_FIN.06.06 © ITT Flygt AB 896218

You might also like