Syngistix for AA Software Release Notes Page 1 of 5

PerkinElmer
Release Notes for

Syngistix for AA SoftwareTM

Version 3.1

Review this document before beginning the installation process.

This document provides the following information:

 About this Product


 Features
 Upgrading from WinLab
 System Requirements
 Improvements in Version 3.1
 Software Operation Tips
 Known Software Issues for Version 3.1

ABOUT THIS PRODUCT


TM
Syngistix for AA is a newly designed software package to control the AAnalyst and PinAAcle line of AA
instruments. Developed for the Microsoft® Windows® 7\10 operating system, Syngistix for AA Software
incorporates a new easy-to-use interface with a modern appearance. Syngistix for AA is part of the
broader Syngistix platform that controls all of the inorganic instrument lines for improved user training and
harmonized functionality.

FEATURES
This highly usable product was developed by a team of application experts, laboratory managers, graphic
designers, and users from all over the world. Sample analysis, scheduling, and data reporting can be
handled easily and efficiently.
Operation is simplified. Based on the familiar Microsoft® Windows® ribbon and graphics, the software has
easy-to-use graphics and familiar menus.
Complete system controls and useful online information are at the user's fingertips, making procedures
simple and routine, even for new operators with minimal training in AA lab procedures. Less training is
required and time can be saved, hence increasing lab productivity.
The automation of many routine tasks not only saves time, but also avoids expensive, time-consuming errors.
Comprehensive data reprocessing and reporting capabilities include: built-in QC automation routines; full
data reprocessing from stored spectra; methods and data stored in a commercial database; and easy
generation of customized reports using off-the-shelf word processor or spreadsheet programs.
The flexibility of Syngistix should allow you to comply with all the various quality control protocols and
regulatory procedures associated with Good Laboratory Practice (GLP) and Good Automated Laboratory
Practice (GALP) requirements.

Copyright © PerkinElmer 2017 May 15, 2017


Syngistix for AA Software Release Notes Page 2 of 5

Upgrading from WinLab


When upgrading from WinLab to Syngistix you will have the same functionality that you have become
accustomed to with many new features that provide a simplified workflow. Some of the new features are:

 Ribbon Style Interface - Consolidates the Workflow to 5 tabs with no hidden menus.
 Data Viewer - This is a tabular data view to compliment the classic results view and allows
exporting data directly to Excel.
 Expandable Windows (specifically Continuous Graphics, as more time/data points are added if
you expand horizontally)
 Updated Graphics and User Interfaces - Provides a clean look to view your data and information.
 INconX™ - Mobile application to view Syngistix data and control the plasma from an iDevice.
 Consolidated Analysis Window - Combines Automated and Manual analysis with a common run
list in one window.
 Status Panel (with quick links) - Provides a quick view of your current status and by double-
clicking a graphic to display its associated dialog.
 Right-click Menus for Display Options - Provides easy navigation to functions in dialogs.
 Most Recently Used Mechanism - Displays the last five methods/files opened.
 Combined Devices Window - Puts your devices in one dialog for easy control.

SYSTEM REQUIREMENTS
Important Installation Information

It is required that the software be installed by a user who has administrator privileges for that local
workstation. This can be verified by checking the User Management under Control Panel > Users and
Passwords.

In order to use the security features of Syngistix, the drives where the applications and data reside must
be NTFS. See Disk Administrator under Control Panel > Administrative Tools > Computer
Management > Storage > Disk Management to determine if your drives are FAT or NTFS.

For instruments that use IEEE communication, Syngistix for AA requires National Instruments IEEE driver
version 16.0.0. This driver can be found in the GPIB directory of the CD-ROM.

Please refer to the Syngistix Installation.pdf (Installation Guide) file on the CD-ROM for additional
information.

Computer Requirements

Syngistix for AA version 3.1 requires Microsoft® Windows® 7 with Service Pack 1(64bit) or Microsoft®
Windows® 10(64bit). A computer with 4 GB RAM and a 250 GB or larger hard disk drive is the minimum
configuration recommended.
It is also recommended to use a video display setting greater than 256 colors with a screen resolution at
800 x 600 or higher. To change the screen resolution click Start > Control Panel and then, under
Appearance and Personalization, click Adjust screen resolution.

It is recommended that "Aero" display themes be used on Windows 7 systems. To change the Windows 7
theme click Start > Control Panel > Personalization and select one of the Aero themes for the Window Color.

Copyright © PerkinElmer 2017 May 15, 2017


Syngistix for AA Software Release Notes Page 3 of 5

Printer Considerations

If you encounter problems printing, especially graphics, check that you are using the manufacturer's most
current printer driver. These can be obtained by downloading the driver from their web site.

Reconfiguring Syngistix for AA

If Syngistix for AA has already been installed on your system and you only need to change the hardware
configuration (e.g. instrument model, autosampler type, etc.), follow these steps: Close the application,
Click on Start > All Programs > PerkinElmer Syngistix for AA > Reconfigure. In the dialog that appears,
select the options for the desired configuration. The Windows 10 steps: Close the application, Click on
Start > All Apps > PerkinElmer Syngistix for AA > Reconfigure.
Notes:
1) Only a user with Administrative privileges can launch the Reconfigure routine.
2) The application will need to be closed for the desired changes to take effect and then re-opened.

Removing Syngistix for AA

To remove Syngistix for AA from your system, use the Windows Uninstall routine under Control Panel >
Programs and Features. Click on PerkinElmer Syngistix for AA and then click Uninstall in the top menu
bar; the Uninstall Shield starts. When finished, you will see the message "Uninstall Completed." This
message may go on to say that "Some of the elements could not be removed..." This is normal.
Simply click on the OK button.

You will also need to remove any User directories or files that were stored in other directories.

Information for Cetac Autosampler Users

Launch Syngistix for AA and select the appropriate tray file to match the Cetac autosampler trays you are
using. Trays can be selected from the Syngistix application under the Instrument tab > Devices >
Autosampler tab > Tray type. Click on the Browse icon. Under the Cetac directory, there are several tray
files to choose from.

Autosampler Tray Files

Tray files are located under C:\Users\Public\ PerkinElmer Syngistix \AA\SystemFiles\Autosampler Trays.
These files can be modified by users who may want to create custom autosampler tray files.

Note: Tray H (140 positions) consists of one 20 position rack (P/N B314-0621) and two 60 position
racks (P/N B314-0618).

Improvements in Version 3.1


Support English and Chinese for User Interface.

Software Operation Tips


See the on-line Help (F1 key) or Syngistix Software Guide for more information on the following topics.
Running User Setup
Always, when running User Set up, even if you are the original administrator, you should run as an
administrator by right clicking on User Setup and select “Run as administrator”. Otherwise you won’t
have the correct access.

Right-Click Menus
In the right-click menus on the editable sections do not select any of the following menu selections at
the bottom of the pop-up menu; Right to left Reading order, Show Unicode control characters, Insert

Copyright © PerkinElmer 2017 May 15, 2017


Syngistix for AA Software Release Notes Page 4 of 5

Unicode control character, Close IME, and Reconversion. This section is automatically put there
by the system and cannot be removed. It is not for customer use and we are unable to change it.

Library Maintenance
IMPORTANT! Library maintenance should be done periodically to prevent your Results Library from
becoming too large which can eventually lead to disk problems. Maintenance procedures include
archiving, deleting, and packing data sets. For additional information, please refer to the
Maintenance and Troubleshooting section of the Data Manager Help.

Dataset Locking
If the application terminates abnormally, the dataset in use may become locked. Datasets can be
unlocked through the Data Manager. Click on "Remove Locks" under Security.

Closing the application


It is recommended that Syngistix be closed prior to shutting down the operating system.

Known Software Issues for Version 3.1


 It is strongly recommended that the same file (Method, SIF, etc.) NOT be opened in both the
Instrument Control mode (IEEE/Ethernet mode) and the Offline mode at the same time. Doing so may
cause a problem with versioning when the files are saved.

 It is recommended that methods that have been imported from WinLab not be saved when using the
Enhanced Security version (ES). Under some circumstances, this can result in incorrect version numbers.

 It is recommended that changing windows' setting Personalize -> Colors -> Show color on Start, taskbar,
action center and title bar to ON, so that the title bar is not missing when maximized in Windows 10.

 In Windows 10 when launching Syngistix with auto sampler models such as AutoPrep 2, Fast Flame 1, or
Fast Flame 2, its hidden base module shows up automatically behind Syngistix window. When this occur
please ignore, do not touch and do not exit the base module in order to sustain the communication with
the auto sampler.

Microsoft Office and Syngistix

Syngistix for AA supports the file format of Microsoft® Access® 2007 and Access 2010.

Software Structural Validation Certificate

The Software Structural Validation Certificate for this version of Syngistix software is included on the root
directory of the CD-ROM in a .pdf format.

Technical Assistance, Defect Reports, and Comments

For technical assistance with Syngistix, please contact your PerkinElmer support organization or Field
Product Specialist.

Software defects and ideas for future releases can be reported using the Syngistix Support Form included
under All Programs > PerkinElmer Syngistix for AA. Information can be sent to:

PerkinElmer Inc.
Inorganic Product Planning

Copyright © PerkinElmer 2017 May 15, 2017


Syngistix for AA Software Release Notes Page 5 of 5

710 Bridgeport Avenue


Shelton, CT 06484 USA

Fax: (203) 925-6718


Email: AATechSupport@perkinelmer.com

For further information on technical issues, contact your local


PerkinElmer representative or visit our web site at
www.perkinelmer.com

Copyright © PerkinElmer 2017 May 15, 2017

You might also like