Professional Documents
Culture Documents
S121 - LEVEL 2 - SOUTH TOWER - GENERAL ARRANGEMENT PLAN Rev.C4 Markup
S121 - LEVEL 2 - SOUTH TOWER - GENERAL ARRANGEMENT PLAN Rev.C4 Markup
R.C. HOB
R.C. HOB
R.C. HOB
R.C. HOB
200 200 200 200 C2 ISSUED FOR CONSTRUCTION AC SB 23.06.21
R.C. HOB
200 750
R.C. HOB
MIN. C3 ISSUED FOR CONSTRUCTION AC SB 07.10.21
MIN. MIN. R.C. HOB MIN.
R.C. HOB R.C. HOB MIN. C4 ISSUED FOR CONSTRUCTION AC SB 25.10.21
DOWN PIPE R.C. HOB R.C. HOB R.C. HOB
PW2
R.C. HOB DOWN PIPE 200 R.C. HOB
R.C. HOB
R.C. HOB
DOWN PIPE DOWN PIPE
DOWN PIPE MIN.
W2
W2
200 200
PW2
DOWN PIPE
W2A
R.C. HOB
W2A
W2
R.C. HOB
W2
DOWN PIPE DRAWING REFERENCE REFERENCE No.
W2
R.C. HOB
W2
DRAWING INDEX S000
R.C. HOB R.C. HOB DOWN PIPE
BA DOWN PIPE R.C. HOB
GENERAL NOTES
RETENTION
S001-S002
S010-S029
200 200 R.C. HOB
C6
PW2
200 CONCRETE COLUMNS S800-S819
MIN. IN-SITU WALLS S820-S879
R.C. HOB
R.C. HOB
DOWN PIPE SLAB ON GROUND DETAILS S950-S951
BB SUSPENDED CONCRETE SLABS S960-S962
PW2
W2A
MIN. MIN. MIN. BRICK WALL DETAILS S985
MIN. 200
W2A
200 HATCH DENOTES
MIN. 200 200 200 200 200 300 THICK DROP PANEL
MIN.
PW2
MIN. MIN. MIN. MIN. MIN. C4 f'c = 65 MPa GENERAL ARRANGEMENT LEGEND
BC 1000 xx* -DENOTES SLAB/BAND BEAM THICKNESS
R.C. HOB
PW2
W2 W2
C8
C1
R.C. HOB
200 TYP.
)
-DENOTES COLUMN OVER
(o
C6
C8
Cx
R.C. HOB
CW2 MIN.
CW2
-DENOTES WALL OVER
BD
PW2*
PW2
W1
PW2
PW2
R.C. HOB
T
AF
LI
LI
200*
-DENOTES LOAD BEARING ELEMENT UNDER
CW2
CW2
CW2
CW2
200*
200*
SH
CW2
200*
FT
FT
CW2
200
LI
200
FT
SH
SH
FT
200
LI
SH
AF
AF
MIN. MIN. -DENOTES LOAD BEARING ELEMENT
W2
T
AF
CW2 MIN. CW2
T
UNDER & OVER
PW2
PW2
PW2
750 -DENOTES BLOCK WALL OVER
200
0
CW2
CW2
200
C1
200
CW2
R.C. HOB
CW2
200 MIN.
PW2*
C8
C.J.
2
-DENOTES CONSTRUCTION JOINT
BE
PW
REFER DRAWING S970 FOR CW2 CW2 2
R.C. HOB
R.C. HOB
STAIR THICKNESS AND 200 S125 -DENOTES SLAB SETDOWN.
PW2*
200
C6
STEP
R.C. HOB
C8
REINFORCEMENT DETAILS REFER TO ARCH. DETAILS FOR ALL LEVELS.
R.C. HOB
200
PW2
PW2
TYPICAL MIN. MIN.
200 DOWN PIPE
PW2*
R.C. HOB
300 THICK DROP PANEL 1.0 BMT BONDEK
C8
R.C. HOB
200 DOWN PIPE C4
(REFER TYPICAL DETAILS)
R.C. HOB
SHELF ANGLE WHERE REQUIRED
R.C. HOB
R.C. HOB
MIN. 200 TO PERIMETER OF LEVEL 2 SLAB 200 200 750
PW2*
R.C. HOB DOWN PIPE
1
DOWN PIPE TO SUPPORT BRICK VENEER. MIN.
C1
MIN. MIN. FORMWORK LEGEND:
1
DESIGN & CERTIFICATION BY OTHERS.
C1
1
200 THICK INSITU R.C. HOB R.C. HOB
C1
R.C. HOB R.C. HOB R.C. HOB
BF UPSTAND WALL
DOWN PIPE R.C. HOB
ALL FORMWORKS SHALL BE OF:-
R.C. HOB CLASS 3 MIN. - GENERALLY
C4
200 THICK INSITU 200 THICK INSITU CLASS 2 MIN. - LIVING AREA WITH
UPSTAND WALL UPSTAND WALL DOWN PIPE EXPOSED CONCRETE FINISH
CLASS 1 MIN. - REFER ARCHITECT
LIGHT WEIGHT FEATURE
(D&C BY OTHERS)
WALL SCHEDULE
MARK WIDTH f'c (MPa) REMARKS
LEVEL 2 - SOUTH TOWER - GENERAL ARRANGEMENT PLAN CW1
CW1A
250
300
50
50
INSITU CORE WALL
INSITU CORE WALL
SCALE: 1 : 100
CW2 200 50 INSITU CORE WALL
CW3 200 40 INSITU CORE WALL
CW4 200 40 INSITU CORE WALL
PW2 200 40 PRECAST FACADE WALL
PW2* 200 50 PRECAST FACADE WALL
W1 250 50 INSITU WALL
W1A 250 50 INSITU WALL
W1B 250 40 INSITU WALL
W2 200 50 INSITU WALL
W2A 200 65 INSITU WALL SOUTH TOWER
W3 200 40 INSITU WALL
W4 200 40 INSITU WALL
W7 200 40 INSITU WALL Key Plan
W8 200 50 N.L.B INSITU WALL
W9 300 50 INSITU WALL
CONSTRUCTION ISSUE
C:\Users\Ramu Karnati\Documents\ASHOK LOCAL FILES\WD19112_159 Epping Rd, Macquarie Park\WD19112_159 Epping Rd, Macquarie Park_LOCAL_Ramu Karnati.rvt
STRUCTURAL DRAWING
CONCRETE COLUMN SCHEDULE
MARK SIZE f'c (MPa) REMARKS
C1 1000 x 250 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C1A 1000 x 250 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C1B 1000 x 250 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C2 1000 x 400 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C2A 1000 x 400 80 INSITU CONCRETE COLUMN
C2B 1000 x 400 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C3 1000 x 450 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C4 400 x 400 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C6 650 DIA. 65 INSITU CONCRETE COLUMN
C7 2000 x 250 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C8 2000 x 200 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C8A 2000 x 220 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C9 2200 x 220 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN S T R U C T U R A L E N G I N E E R I N G
C9A 2200 x 200 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN SYDNEY OFFICE:
SUITE 301, LEVEL 3, 19A BOUNDARY STREET
MELBOURNE OFFICE:
LEVEL 2, 31 QUEEN STREET
C9B 2000 x 200 40 INSITU CONCRETE COLUMN RUSHCUTTERS BAY, NSW, AUSTRALIA 2011
T: +61 2 9690 2488
MELBOURNE, VIC, AUSTRALIA 3000
T: +61 3 9614 7155
C10 1000 x 250 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN CLIENT
C11 260 x 700 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C12 400 DIA. REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C13 2400 x 200 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN VIMG
C14 1000 x 350 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C15 700 x 350 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN
C16 1700 x 300 REFER DWG. S805 FOR DETAIL INSITU CONCRETE COLUMN PROJECT
NOTES: PLAN
1. ALL PENETRATIONS TO BE REVIEWED AND RESOLVED.
THICKNESS f'c (MPa) REMARKS
2. ALL SERVICES PENETRATIONS TO BE CO-ORDINATED AND APPROVED BY WEBBER DESIGN. 200 50 MPa PT SLAB BY D&C CONTRACTOR DATE DESIGNED BY CHECKED BY
3. REBATES AND CAST IN PLATES FOR STRUCTURAL STEEL WORK AND FACADE TO BE 200* 40 MPa R.C SLAB (N12-200 TOP & BOTTOM E.W.) OCT 2020 AC AC
CO-ORDINATED WITH ARCHITECT. 750 50 MPa PT SLAB BY D&C CONTRACTOR
4. CONTRACTOR SHALL ALLOW FOR CONSTRUCTION JOINTS AS REQUIRED. SCALES AT B1 DRAWN BY APPROVED BY