Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Product Datasheet

DAN-LIQ-DS-1200-0609
June 2009 Liquid Turbine Flow Meters

Daniel Series 1200


®

Liquid Turbine Flow Meter

www.daniel.com
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

Daniel Series 1200 Liquid Turbine Flow Meter


®

Highly Accurate, Cost-Effective Turbine Meter with Dual


Outputs in a Single Housing

The Daniel Series 1200 Liquid Turbine Flow Meter is a Features and Benefits:
volumetric flow metering and transmitting device, used Output linear with flow rate
extensively in the petroleum industry for the accurate
measurement of liquid hydrocarbons. The meter's simple Rangeability of 10 to 1
configuration assures high flow rates, extended flow range
Horizontal or vertical installation
and sustained accuracy, with superior repeatability and
unmatched reliability. Available in 1 to 4 inch sizes
The primary reason for this superior performance with light Superior accuracy and repeatability
hydrocarbons is the Series 1200 lightweight rotor. This
High frequency pulse resolution
rotor is free spinning on flow-through bearings, which
have a self cleaning design. Uniform pulse signal output
The Series 1200 Turbine Flow Meter is versatile and Universal Mounting Box (UMB) housing dual
operates in both horizontal and vertical installations. channel preamplifier and 2 pick-offs
It features an expanding hanger to center the internal
assembly in the body. All turbine meter installations Improved serviceability allows easy access to pick-offs
and reduces installation costs
should incorporate a method for flow conditioning by
using either a standard upstream and downstream section Simple, easy to maintain, field mountable pick-offs
(per API chapter 5, section 3) or a flow conditioning require no interruption of conduit lines
plate. Series 1200 turbine meters have an integral flow
conditioning plate as a standard feature for sizes 1.5 inch Explosion proof / weather proof housing
and larger. OIML Approval (3 to 4 inch) 1.32 - 01060311
This meter is designed for use within the guidelines of Optional Teflon coated rotors for reduced buildup coating
API Standards, Chapter 5.3, (Measurement of Liquid
Hydrocarbon by Turbine Meter) and the test procedures of Integral Flow Conditioner
API, Chapter 4 (Proving Systems).

Page 
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

Specifications:
Please consult Daniel if your requirements are outside the specifications noted below. Improved performance, premium linearity and
other product and material offerings may be available depending on the application. For world area locations and contact information,
refer to the back page of the data sheet.

Meter Performance Materials of Construction


Sizes 1", 1.5" and 2" Sizes 1", 1.5" and 2"
• Linearity: ± 0.25% • Meter Body and Flanges:
• Repeatability: ± 0.02% • 304 Stainless Steel
Sizes 3" and 4" • Internals:
• Linearity: ± 0.15% • Aluminum and stainless steel
• Repeatability: ± 0.02% • Bearings:
• Stainless steel ball bearings
Process Parameters Sizes 3" and 4"
Temperature Ratings • Meter Body and Flanges:
Carbon Steel stainless steel
• Carbon Steel (standard)
-20°F to 180°F -40°F to 180°F
(-29°C to 82°C) (-40°C to 82°C) • Stainless Steel (optional)
• Internals:
Pressure Ratings
Carbon stainless • Aluminum and stainless steel
Size (inch) ansi class Steel steel
• Bearings:
1" - 4" 150 285 psi 275 psi
1" - 4" 300 740 psi 720 psi • Stainless steel ball bearings (standard)

Max Pressure in PSI @ 100ºF • Tungsten carbide journal (optional)


UMB (Universal Mounting Box) Housing Material
• 356 T6 Aluminum
• (2) 3/4" NPT conduit connections
RMB (Remote Mounting Box) Housing Material
• 356 T6 Aluminum
• (2) 3/4" NPT conduit connections
Flow Conditioner Plate Material
• Sizes 1.5" and 2"
• Delrin 150
®

• Sizes 3" and 4"


• Delrin 150 (standard)
®

• 6061 T6 Aluminum (optional)


Flange type
• ANSI RF (Raise Face) Flanges Standard
For other flange options, please consult Daniel
Page 
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

Pick-off Specifications Variable Voltage Output


Type: 2-wire reluctance Output: 0 to supply voltage square wave
Resistance: 600 - 900 Ohms Frequency range: 0 to 5 kHz
Inductance: 250 mH max Loading: 1 kOhm internal pull-up
Output: Sinusoidal 40mV p-p minimum @minimum
flow with preamplifier load Open Collector Output
Optional: 2 pick-off coils Output: Square wave
Frequency range: 0 to 5 kHz
Preamplifier Performance - Maximum voltage: 30 Vdc
Dual Channel Preamplifier
Maximum current: 125 mA
Inputs:
Maximum power: 0.5 Watts
Supply voltage: 10 - 30 Vdc
Minimum input signal amplitude: 40mV p-p minimum
Transmission Distance
Without preamp: 20 ft (6.1m)
Powered Pulse Output Belden 88442 or equivalent
Output: 0 to 5V square wave With preamp: 3,000 ft (914m)
Frequency range: 0 to 5 kHz Belden 8770 or equivalent
Loading: 1 kOhm internal pull-up
Hazardous Area Classifications
UL / C-UL Class 1, Division 1, Groups C&D

DUAL CHANNEL PREAMP CE certified Ex d IIB T6 (ATEX)


TERMINAL IDENTIFICATION NEMA 4
CUSTOMER CONNECTIONS

TB1 1 2 3 4 5
CHA. A OUTPUT
+10 TO 30 VDC

CHA. B OUTPUT
COMMON

COMMON

BLACK OR
WHITE RED
1 2

1 2

PICKOFF PICKOFF

BLACK OR WHITE
TB2 TB3
RED
CHANNEL A CHANNEL B

Preamp Jumper
PREAMP JUMPER Configurations
CONFIGURATIONS
Jumper A JUMPER POSITIONSB Out
J3 J4
JUMPER
J1 - Chan. A Input A N/A B40mV. PP Min OUT N/A
J1-CHAN. A INPUT N/A 40mV. PP MIN N/A
J1 - Chan. B Input N/A 40mV. PP Min N/A
J1-CHAN. B INPUT N/A 40mV. PP MIN N/A
J1 J2 J3 - Chan. A Output 5v.Pulse
J3-CHAN. A OUTPUT 5V.PULSE SUP. VOLT. PULSEPulse
Sup. Volt. (10-30 (10
VDC)- 30 VDC)
O.C. O.C.
J4-CHAN.
J4 - Chan.BBOUTPUT
Output 5V.PULSE
5v.Pulse SUP. VOLT. PULSEPulse
Sup. Volt. (10-30 (10
VDC) O.C.
- 30 VDC) O.C.

Page 
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

Daniel Series 1200 Liquid Turbine Flow Meter and Flow Straightening Sections
®

Size A B C D E F G
(Inches) Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm
1 8 203 4 101.6 6.75 171.5 5 127 5 127 18 457 5 127
1.5 9 229 4.5 114.3 7 178 7.5 190 7.5 190 24 610 5.75 146
2 9 229 4.5 114.3 7.25 184 10 254 10 254 29 737 6 152
3 10 254 3 7/8 98 7.75 197 15 381 15 381 40 1,015 6.5 165
4 12 305 4.5 114 8.25 209 20 508 20 508 52 1,320 7 178

Approximate Shipping Weight


Size ANSI Class 150 ANSI Class 300
(Inches) Lbs Kg Lbs Kg
1 13 6 13 6
1.5 16 7 22 10
2 20 9 22 10
3 32 15 41 19
4 47 21 64 29
CF = Consult Factory

Page 
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

DANIEL SERIES 1200 LIQUID TURBINE FLOw METER: MODEL SELECTION MATRIX
®

T CODE TURBINE BASE CODE


CODE SIZE BPH P / BBL M3 / HR P / M3 GPM P / GAL ANSI DIN HSG.CS FLG.CS HSG SS FLG. SS
Class 2501 INT. SS / AL INT. SS / AL
01 1" 8.6 TO 86 33,600 1.36 TO 211,360 6 TO 60 800 150 pn16 n/a Available
13.7
300 pn40 n/a
15 1.5" 18.6 TO 16,800 2.0 TO 105,680 13 TO 130 400 150 pn16 n/a
186 29.696
300 pn40 n/a
02 2" 31.5 TO 7,560 5.0 TO 50 47,556 22 TO 220 180 150 pn16 Available
315
300 pn40
03 3" 93 TO 930 2,148 14.8 TO 13,738 65 TO 650 52 150 pn16
148
300 pn40
04 4" 143 TO 966 23 TO 230 6,077 100 TO 23 150 pn16
1,430 1,000
300 pn40
CODE FLANGE TYPE
A 150 ANSI R.F. FLANGES 125 - 250 AARH
B 300 ANSI R.F. FLANGES 125 - 250 AARH
P DIN 2501 PN16, 16 BAR MWP
Q DIN 2501 PN40, 40 BAR MWP
CODE BEARING TYPE
E SERIES 1200 STAINLESS STEEL BEARING
F SERIES 1200 TUNGSTeN CARBIDE BEARING - 3" AND 4" ONLY
CODE METER OUTPUT
A 1 PICKOFF, DUAL Channel PREAMP
D 2 PICKOFFS, DUAL Channel PREAMP - 90º electrical is standard for 2 pickoffs
CODE METROLOGY APPROVALS
1 UNSPECIFIED
2 NTEP, CC: 90 - 118 (FOR 1.5" METER: 6 gpm TO 130 gpm: FOR EXTENDED FLOW RANGES SEE CERTIFICATE)
3 MEASUREMENT CANADA: AV - 2264 (5:1 TURNDOWN FOR DIESEL FUEL AND STOVE OIL)
CODE RELATIVE DENSITY OF CALIBRATION FLUID
J 0.78 - 0.79 (MINERAL SPIRITS)
CODE FLOW DIRECTION / FLOW CONDITIONING PLATE
A HORIZONTAL 1" ONLY
B VERTICAL 1" ONLY
C HORIZONTAL With FLOW CONDITIONING PLATE (THERMOPLASTIC FLOW CONDITIONING PLATE) 1.5" THRU 4" ONLY
D VERTICAL With FLOW CONDITIONING PLATE, UPWARD FLOW ONLY (THERMOPLASTIC FLOW CONDITIONING PLATE) 1.5" THRU 4" ONLY
F HORIZONTAL With FLOW CONDITIONING PLATE (ALUMINUM FLOW CONDITIONING PLATE) 3" AND 4" ONLY
G VERTICAL With FLOW CONDITIONING PLATE, UPWARD FLOW ONLY (ALUMINUM FLOW CONDITIONING PLATE) 3" AND 4" ONLY
NOTE: FLOW CONDITIONING PLATE IS NOT APPLICABLE FOR THE 1" METER
CODE MATERIALS OF CONSTRUCTION: temperature RANGES APPLICABLE TO COMPLETE METER INCLUDING
PICKOFF AND PREAMP -20 TO 180ºF, -29 TO 82ºc (carbon steel); -40 to 180ºF, -40 to 82ºC (stainless steel)
HSG FLANGE INTERNALS
A CS CS SS / AL / BALL BEARING WITH TEFLON COATED ROTOR 2", 3" AND 4" ONLY
4 CS CS SS / AL / BALL BEARING 2", 3" AND 4" ONLY
B 304 SS 304 SS SS / AL / BALL BEARING WITH TEFLON COATED ROTOR 1" THRU 4" ONLY
9 CS CS SS / AL / TUNGSTEN CARBIDE 3" AND 4" ONLY
C CS CS SS / AL / TUNGSTEN CARBIDE WITH TEFLON COATED ROTOR 3" AND 4" ONLY
7 304 SS 304 SS SS / AL BALL BEARING 1" THRU 4" ONLY
D 304 SS 304 SS SS / AL / TUNGSTEN CARBIDE WITH TEFLON COATED ROTOR 3" AND 4" ONLY
8 304 SS 304 SS SS / AL / TUNGSTEN CARBIDE 3" AND 4" ONLY

Page 
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

CODE REGISTER TYPE / OUTPUT


A NONE
D ELECTRIC REGISTER - MRT 97
CODE REGISTER MOUNTING
A NONE
B INTEGRAL
C REMOTE
CODE LINEARITY AND SPECIAL FEATURES
A UNSPECIFIED
C LINEARITY: ± 0.25% 1", 1.5" AND 2"; ± 0.15% 3" AND 4"
D LINEARITY: ± 0.15% 1", 1.5" AND 2" ONLY
CODE APPROVALS
A NONE
G CCA / UL / C-UL 3" AND 4" ONLY (canada only)
J UL / C-UL
K CE - CE MARK INCLUDES SEP OR PED, ATEX AND EMC
CODE DOCUMENTATION
A NONE
C MATERIAL TEST REPORT: (dOC MTR)
D NACE WITH MATERIAL TEST REPORT: DOC QA - 1A). (DOC MTR)

UMB Cover

Daniel Series 1200 Liquid Turbine Flow Meter


®

(Shown with tungsten carbide bearings)

Dual Channel
Pre-amplifer

Pickoffs

UMB Housing

O-ring

Outlet
Diffuser
Cap
Shaft
Hanger Sleeve
Blades
Flow Conditioning Plate

Rotor
Thrust Assembly
Washer with
Bearing
Hanger
Page  Hub
Product Datasheet
DAN-LIQ-DS-1200-0609
June 2009

Emerson Process Management Daniel Measurement and Control, Inc. ("Daniel") is a wholly owned subsidiary
Daniel Measurement and Control, Inc. of Emerson Electric Co., and a division of Emerson Process Management. The
Daniel name and logo are registered trademarks of Daniel Industries, Inc. The
World Area Headquarters Emerson logo is a registered trademark and service mark of Emerson Electric
Houston, Texas, USA Co. All other trademarks are the property of their respective companies. The
T: 713-467-6000, F: 713-827-3880 contents of this publication are presented for informational purposes only, and
USA Toll Free 1-888-FLOW-001 while every effort has been made to ensure their accuracy, they are not to
www.daniel.com be construed as warranties or guarantees, express or implied, regarding the
products or services described herein or their use or applicability. All sales are
Canada: Calgary, Alberta governed by Daniels' terms and conditions which are available upon request.
T: 403.279.1879, F: 403.236.1337 We reserve the right to modify or improve the designs or specifications of such
products at any time. Daniel does not assume responsibility for the selection,
Asia Pacific: Singapore use or maintenance of any product. Responsibility for proper selection, use
T: +65.6777.8211, F: +65.6770.8001 and maintenance of any Daniel product remains solely with the purchaser and
end-user. The Daniel Series 1200 Liquid Turbine Flow Meter is protected by
Europe: Stirling, Scotland U.S. and international patents and patents pending.
T: +44 1786 433400, F: +44 1786 433401

Mid-East, Africa: Dubai


T: +971 (4) 883.5235, F: +971 (4) 883.5312

2009 Daniel Measurement and Control, Inc. All Rights Reserved. Unauthorized duplication in whole or in part is prohibited. Printed in the USA.
DAN-LIQ-DS-1200-0609