Professional Documents
Culture Documents
Optex Incorporated Description: Output and Enclosure
Optex Incorporated Description: Output and Enclosure
NOTE: Words/statements within square brackets [ ] may be included when appropriate, or when selection is required.
Doc #: 3440-0322
ALARM OPERATION continually monitor for gradual changes in
the signal’s strength caused by changing
A condition of alarm shall occur when
weather conditions. It shall adjust the
the alarm conditions are met. The Beam
sensitivity accordingly to maintain the proper
Interruption Period shall be adjustable within
signal level for the current environmental
the range of 50 ~ 500 msec. to increase
conditions.
stability while maintaining reliability at every
installation site. A selectable 4 channel
[Each] [The] detector shall provide
beam frequency with automatic
protection against rain, dust, and insects by
synchronization shall be available for
means of a sealed enclosure housing. The
models AX-100 ALPHA and AX-200 ALPHA.
Rubber O-Ring and Rubber Grommets
The beam characteristics shall be pulsed
(IP55) used in the detector[s] shall prevent
infrared. The Alarm Period shall be 2.0 ± 1
rain, dust, and tiny insects from adversely
seconds nominal. The Alarm Output shall
affecting performance.
be capable of handling 28VDC, 0.2A max.,
Form C Relay. [Each] [The] detector shall
[Each] [The] detector shall feature frost
signal the condition of alarm using a Form C
and dew protection. An anti-frost and
Relay with terminal strip connections. The
convex visor design shall be incorporated to
detector[s] shall also contain a tamper
protect the detector[s] from the effect of frost
switch on the receiver only that shall open
or snow.
when the cover is removed.
[Each] [The] detector shall utilize Twin
Synchronized Pulsed Beams with size
SENSOR STABILITY
analysis technology to eliminate false alarms
[Each] [The] detector shall feature due to birds or flying objects. The “And
protection against Lighting and High EMI Gate” dual beams shall require
Disturbances. An improved EMI Surge simultaneous interruption of both beams to
Absorber and High Surge Resistiveness trigger an activation. No activation shall be
Relay shall maintain stable operation even generated when a bird or falling leaves
in the most lightning prone areas, and shall break just one beam.
remain stable against over 14kV of lightning
surge.
Doc #: 3440-0322
200ft (60m) Outdoor, and 400ft (120m) MODEL
Indoor, with a Maximum Arrival Distance of
The Intrusion Detector shall be model
2000ft (600m).
AX-100 PLUS (Outdoor Short-Range
Photoelectric Intrusion Detector) [or] [model
The mounting height of the detector[s]
AX-200 PLUS] [or] [model AX-100 ALPHA]
shall be within the range of 0.8 ~ 1.2m (2.7 ~
[or] [model AX-200 ALPHA], [with] [optional
4ft).
Back Cover BC-2] [or] [optional Heating Unit
HU-2].
Fine optical beam alignment shall also
be incorporated into the detector[s]. The
rotating dial shall allow the installer to finely
adjust the beam easily either horizontally
(180°/ ± 90°) or vertically (10°/ ± 5°), with or
without the use of a screw (finger
adjustable).
Doc #: 3440-0322