Page 3 7 1/16” 3000 TGR – Manual
Exploded view parts
Page 4 7 1/16” 3000 TGR
Exploded view parts
Page 5 7 1/16” 5000 TGR
Exploded view parts
Page 6 9” 3000 TGR
Exploded view parts
Page 7 TGR Weights and Measures
Page 8 7 1/16” 3000 TA
Exploded view parts
Page 9 7 1/16” 5000 TA
Exploded view parts
Page 10 9” 3000 TA
Exploded view parts
Page 11 TA Weights and Measures
Page 12 Coming Soon
Page 13 Coming Soon
Page 14 Contact Information
Page 15 Terms and Conditions
Page 1
Steel Tech BOP, LP
105, 3901 54 Ave NE
Calgary, AB
Canada T3J 3W5
(403)554-BOPS
(2677)
steeltechbop@telus.net
Mission Statement
Industry requires all of it's partner organizations to raise the
level of safety and reduce the liability for employee, environmental
and corporate entities. Steel Tech BOP is determined to become a
market force. Our commitment to quality is surpassed only by our
intent to surpass our customers’ expectation. Steel Tech owners,
partners, sub-contractors and agents will foster a positive
environment where manufacturing, service and customers all
contribute to the success of the industry and product. Our
commitment to all levels and areas will be demonstrated through the
final product. Owners, Management, Employees and sub-contractors
will combine efforts to maintain constant product integrity,
scheduled deliveries, economical BOP and parts price, and Industry
Satisfaction as "Leaders" in our product.
Page 2
Steel Tech 7 1/16” 3000 TGR Type Gate Ram Blowout Preventer
Manual Operated
1 10
18
14
8 12
20
42
35 2
36 23
30
41 31
19 24
40
3 9
27 13
33 34
29 15
32 4
2 39
6
28 25
11
26
ITEM Description QUANTITY PART NUMBER ITEM Description QUANTITY PART NUMBER
SINGLE DOUBLE SINGLE DOUBLE
Page 3
Steel Tech 7 1/16” 3000 TGR Type Gate Ram Blowout Preventer
1 10
5
18
14
8 12
21
20
42
35 22
36 23
30
41 31 32
19 24
40
33
3 9
27 13
34
29 15
4 39
2
6
28 25
11
37
26
38
16
17
ITEM Description QUANTITY PART NUMBER ITEM Description QUANTITY PART NUMBER
SINGLE DOUBLE SINGLE DOUBLE
Page 4
Steel Tech 7 1/16” 5000 TGR Type Gate Ram Blowout Preventer
1 10
5
18
14
8 12
21
20
42
35 22
36 23
30
41 31 32
19 24
40
33
3 9
27 13
34
29 15
4 39
2
6
28 25
11
37
26
38
16
17
ITEM Description QUANTITY PART NUMBER ITEM Description QUANTITY PART NUMBER
SINGLE DOUBLE SINGLE DOUBLE
Page 5
Steel Tech 9” 3000 TGR Type Gate Ram Blowout Preventer
1 10
5
18
14
8 12
21
20
42
35 22
36 23
30
41 31 32
19 24
40
33
3 9
27 13
34
29 15
4 39
2
6
28 25
11
37
26
38
16
17
ITEM Description QUANTITY PART NUMBER ITEM Description QUANTITY PART NUMBER
SINGLE DOUBLE SINGLE DOUBLE
Page 6
TGR TYPE GATE RAM
TABLE 1: Physical Data
Piston Stroke Length OPEN 4 1/4” 4 1/4” 4 1/4” 4 1/4” 5 1/8” 5 1/8”
Width 22 22 22 22 25 25
Volumes shown do not include any other hose, connection or vessel reserve volume.
An accumulator, independent of other rig functions and capable of closing and opening all chambers with out
recharge, is the
recommended operating system.
Always ensure all connection studs and nuts are in good condition, present, and properly fastened.
Always perform Hydraulic and Well Bore tests prior to use and after any repair/replacement.
Page 7
Steel Tech 7 1/16” 3000 TA Type Annular Blowout Preventer
6 3 Piston 1 TA-003M
4 Lower Housing 1 TA-002M
5 API Cap TE Stud 12 TES-73
10 6 Body to Cap TE Stud 24 TA-013
1
7 API Cap Nut 12 2HN-73
8 Body Nylock Nut 24 TA-012
9
9 Adapter Ring Lug 2 TA-010
11 10 Lifting Clevis 2 TA-022
11 Packing Element 1
12
Natural TA-005
13 Nitrile TA-006
12 Adapter Ring OD Seal 1 TA-023
2 13 Cap Seal 1 TA-024
14 Adapter Ring Scraper Seal 1 TA-025
14 15 Adapter Ring Hydraulic Seal 1 TA-026
16
15 16 Adapter Ring Wear Band 1 TA-009
17 Piston Wear Band 2 TA-008
3
18 Piston OD Seal 2 TA-027
17 19 Lower Housing Scraper Seal 1 TA-028
18
20 Lower Housing Seal 2 TA-029
21 Lower Housing Wear Band 1 TA-009
19 22 Hydraulic Port Plugs 2 PP-1
20 23 Seal Kit – 1 TA-007
21
22
Page 8
Steel Tech 7 1/16” 5000 TA Type Annular Blowout Preventer
6 3 Piston 1 TA-003M
4 Lower Housing 1 TA-002M5
5 API Cap TE Stud 12 TES-75
10 6 Body to Cap TE Stud 24 TA-013
1
7 API Cap Nut 12 2HN-75
8 Body Nylock Nut 24 TA-012
9
9 Adapter Ring Lug 2 TA-010
11 10 Lifting Clevis 2 TA-022
11 Packing Element 1
12
Natural TA-005
13 Nitrile TA-006
12 Adapter Ring OD Seal 1 TA-023
2 13 Cap Seal 1 TA-024
14 Adapter Ring Scraper Seal 1 TA-025
14 15 Adapter Ring Hydraulic Seal 1 TA-026
16
15 16 Adapter Ring Wear Band 1 TA-009
17 Piston Wear Band 2 TA-008
3
18 Piston OD Seal 2 TA-027
17 19 Lower Housing Scraper Seal 1 TA-028
18
20 Lower Housing Seal 2 TA-029
21 Lower Housing Wear Band 1 TA-009
19 22 Hydraulic Port Plugs 2 PP-1
20 23 Seal Kit – 1 TA-007
21
22
Page 9
Steel Tech 9” 3000 TA Type Annular Blowout Preventer
6 3 Piston 1 TA-017M
4 Lower Housing 1 TA-015M5
5 API Cap TE Stud 12 TES-93
10 6 Body to Cap TE Stud 24 TA-021
1
7 API Cap Nut 12 2HN-75
8 Body Nylock Nut 24 TA-012
9
9 Adapter Ring Lug N/A N/A
11 10 Lifting Clevis 2 TA-022
11 Packing Element 1
12
Natural TA-018
13 Nitrile TA-019
12 Adapter Ring OD Seal 1 TA-030
2 13 Cap Seal 1 TA-031
14 Adapter Ring Scraper Seal 1 TA-032
14 15 Adapter Ring Hydraulic Seal 1 TA-033
16
15 16 Adapter Ring Wear Band 1 TA-009
17 Piston Wear Band 2 TA-008
3
18 Piston OD Seal 2 TA-034
17 19 Lower Housing Scraper Seal 1 TA-035
18
20 Lower Housing Seal 1 TA-036
21 Lower Housing Wear Band 1 TA-008
19 22 Hydraulic Port Plugs 2 PP-1
20 23 Seal Kit – 1 TA-020
21
22
Page 10
TA TYPE ANNULAR
TABLE 2: Physical Data
Diameter 29 29 35 1/2
Upper Housing
Element
Adapter Ring
Piston
Lower Housing
Volumes shown do not include any other hose, connection or vessel reserve volume.
An accumulator, independent of other rig functions and capable of closing and opening all chambers with out
recharge, is the recommended operating system.
Always ensure all connection studs and nuts are in good condition, present, and properly fastened.
Always perform Hydraulic and Well Bore tests prior to use and after any repair/replacement.
Never exceed MAXIMUM WORKING PRESSURE.
Page 11
Coming July 2007
Page 12
Coming September 2007
Page 13
Please direct all communications
to our Canadian office: Or Your Local Representative
Email: steeltechbop@telus.net
Fax:
Page 14
Terms and Conditions of Sale
1)SHIPPING: All shipments are F.O.B. our Calgary warehouse, unless otherwise quoted.
2)CURRENCY: All invoices are issued in Canadian funds. However, conversion to a customer’s
currency choice can be shown on invoice. Payment is acceptable in Currency
specified.
3)QUOTATIONS: Quotations are valid only for the length of time and upon the terms specified in
each quotation.
4)WARRANTY: Steel Tech BOP LP warrants all materials, products and supplies
manufactured by it to be free from defects in material and workmanship under
normal use and service when installed and used in the manner intended by Steel
Tech for a period not to exceed one (1) year after delivery. Steeel Tech’s
obligation under this warranty is expressly limited (parts and labour) to repair
or replacement, at its option of any material, products or supplies returned to
Steel Tech, Calgary, Alberta, Canada, and which are determined by Steel Tech
to be defective. All freight or delivery charges are for customer’s account.
This is the sole warranty of Steel Tech and no other warranty is applicable, either
expressed or implied, in fact or by law.
Products or parts not of Steel Tech manufacture are subject to whatever warranty or guarantee extended to
Steel Tech by the supplier or manufacturer thereof.
a) failures not reported to Steel Tech within the warranty period specified above;
c) failures due to operation, either intentional or otherwise, above rated capacities or in an otherwise improper
manner;
d) products which have been in any way tampered with or altered by anyone other than an authorized represen-
tative of Steel Tech.
f) expenses incurred by customer in an attempt to repair or rework any alleged defective products;
h) products rebuilt, welded, heat-treated or subjected to similar processes performed by other than Steel
Tech.
7) TAXES: The amount of any sales, excise or other taxes, if any, applicable to the goods
covered by an order, shall be added to the invoice as~EXTRA.
8) RETURNED GOODS: Prior permission must be obtained before returning material to us for credit. Shipments must be re-
turned freight prepaid to Steel Tech’s designated location before credit can be issued. A restocking charge
will be made on all orders returned for credit and any costs that may be necessary to return material to
saleable condition will also be charged. No material will be accepted for credit after thirty (30) days from
date of purchase. Products of special design or equipment altered to fit Buyer’s specifications will not be
accepted for credit.
9) CANCELLATION OF ORDER: When an order has been accepted by Steel Tech it may not be
cancelled without our written permission. Cancellation terms will include
compensation for expenses incurred after such order was accepted. Orders for
products or parts of special order design, size or materials are not subject to cancellation after we have
accepted the order.
10) PRICES: Subject to change without notice.
Page 15