SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Acoustical False Ceilings Installation & Final Inspection SAIC-M-1054 18-May-05 CIVIL-
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A Installation Inspection

Space between the ceiling and the roof shall be per the approved IFC
A1 IFC Drawings
drawings to allow for ducts, lighting fixtures and trays.

Cross runners shall be installed to within 0.79mm of their on center


SAES-M-100
A2 spacings (There shall be no visually apparent displacements).
Sec. D
(1997 UBC, Sec. 25.209.4)

The bottom surface of two intersecting runners shall be within 0.38mm of


each other with the abutting members higher than the supporting SAES-M-100
A3
members and within 0.38mm in horizontal alignment. Sec. D
(1997 UBC, Sec. 25.209.4)

Splines used to form concealed joints shall be compatible with the tile
SAES-M-100
A4 and its kerf designs so that adjacent tiles will be horizontal and even at
Sec. D
joints. (1997 UBC, Sec. 25.209.5)

There shall be no visually apparent angular displacement of the


SAES-M-100
A5 longitudinal axis of one member with respect to the other.
Sec. D
(1997 UBC, Sec. 25.203.4)

Abutting sections of main runner shall be joined by means of suitable


connections such as splices, interlocking ends, tab locks, pin locks or SAES-M-100
A6
other anchors, and shall be per the IFC drawings. Sec. D
(1997 UBC, Sec. 25.209.6)

B Final Inspection

The final assembly shall not deviate from a horizontal, flat planar surface
SAES-M-100
B1 by more than 8mm's in any 3m run in either direction.
Sec. D
(1997 UBC, Sec. 25.209.6)

Assembly devices shall provide sufficient spacing control so that final


SAES-M-100
B2 horizontal gaps between abutting or intersecting members shall not
Sec. D
exceed 0.51mm (0.02"). (1997 UBC, Sec. 25.209.6)

Runners supporting lighting fixtures or ceiling vents shall not rotate more SAES-M-100
B3
than +20 after the fixture loads are imposed. (1997 UBC, Sec. 25.209.7) Sec. D

Page 1 of 2
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Acoustical False Ceilings Installation & Final Inspection SAIC-M-1054 18-May-05 Civil
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-M-100 -- Saudi Aramco Building Code, 30 June 2002
2- 1997 UBC -- Uniform Building Code, 1 January 1997

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 2 of 2