Download as pdf
Download as pdf
You are on page 1of 9
CORRIGENDUM :- FOR NIT NO: P&E/126, Date 20/09/2018 EMPANELMENT OF MANUFACTURERS/VENDORS FOR PROCUREMENT OF (A) UPS. need BATTERIES, (B) BATTERIES AND (C) FOR COMPREHENSIVE AMC OF OLD UPS WHICH ARE INSTALLED BEFORE 13/OCT/2015 RATE CONTRACT BASIS FOR Su BRANCHES AND OFFICES SITUATED IN THE STATES OF BIHAR AND. JHARKHAND START DATE:- 23/09/2018 LAST DATE:-31/10/2018 With reference to the captioned tender, the pre-bid meeting held on 06/10/2018 and Bank authorities have decided to amend the following terms & conditions of Tenders:- S. Existing Tender terms Tender _| Revised / amended as. N page no. 4 Minimum annual turnover of Rs. 100.00/Para-1, Minimum annual turnover of Rs. 100.00 Lacs (Rupees Hundred Lacs only) Pageno-3_| CRORE. (Rupees One Hundred crore only.) Para-5:- Must produce Solvency Para-5, Must produce Solvency Certificate for minimum Certificate for minimum of Rs 25.00 Page no-3 of Rs 125.00 lacs issued (Rupees One lacs (Rupees Twenty five Lacs only) hundred andTwenty five Lacs only) (issue date 2 issued (issue date not before: ‘ot before 01.01.2018) by Banker or any other 01.01.2018) by Banker or any other equivalent certificate acceptable to Bank. equivalent certficate acceptable to |__Bank — fi - Last date and time for submission of Pageno.-16 |Last date and time for submission of tenders | 3 |tenders 3.00PM. On 15/10/2018. and _ other 3.00 PM, On 31/10/2018 ee Eres or Pages. |The manufacturers / suppliers should Pageno~3 Condition added- MnfrlOEM/Vendor must. have office / service centre both in| have minimum Eight service center in Bihar and Binar and Jharkhand state for after| Five in Jharkhand, Those who have no service sales service center or less than required nos. have to setup. the service center as above. Before start of | supply | Minimum VAH required as per details Last Para, Minimum VAH Table replaced with Fresh 5 as under: Page-10 |Table, Page-10 8 14 14 (6) AMC of old UPS which is more than Page no-24 (I)Comprehensive AMC including spares for g 7's. in SBI Patna Circle a3 UPS installed before 13/0cv/2015 (Il) Vendor to quote the price only for their own = UPS ee ‘Annexure Annexure-IV replaced with Fresh annexue-IV 7 Price Bid IV, Page 17- (Page 17-22) 31 Tubular batteries, Page _no.- Item Deleted. te 8 10, S.N- 26(8) ASSISTANT [AGER( P&E ) 22 (O} (Manual bye-pass switch [Should be provided }23. Indications [EDICD display to be provided mains on, battery on charge, battery low, Inverter on, % load, On bye-pass, over {temperature etc, 24 Alarm i) Low battery alarm to be provided i) % load i) Main failure / Load on battery alarm to be provided both should be audio visual iv) Over temperature alarm in two stages. 25, Metering Digital panel meter of LCD display system to indicate the following i) A.C. voltage : Inpu/Output i) A.C. current : Input/Output or % load ii) D.C. battery voltage iv) D.C. charging discharging current 1) Frequency — Input/Output 26 Battery set A. SMF batteries (to be installed in ventlated/cooled rooms only) i) Complete with self standing cubical or cabinate i) Make like: Exide / Panasonic / CSB / Numeric / Amraraja Rocket / Max New / U:Plus / AMCO best / HBL. ii) Note: Only valve regulated lead acid (VRLA) type SMF batteries of 20 HR rated capacity electrolyte in paste form are acceptable. Any other type including calcium batteries are not acceptable. 1B. Tubular batteries (to be installed in ventilated room with lexhaust fan is required) i) Maintainable but regular topping necessary i) Complete with stand il) Make lke : Exide, Souther Batteries, Kirloskar, AMCO- insta power Minimum VAH required as per details as under: | UPS Capacity (KVA) 2KVA SkV/ 60 minutes 41. The back-up time at full load shall be 60 minutes. 2. Battery set details to be indicated by the supplier. 3. D.C. terminal voltage 12V. 4. No, of batteries and each battery voltage. 5. Ampere-Hour capacity of each battery. 6. End cell voltage for cut off shall be considered as 1.76 / cell. versa, 23 (O} Manual bye-pass iswitch Should be provided 24 Indications fa) Mains ON with phase indicalion for single phase 13 phase separately forall the phases. b) Inverter ON / OFF / FAULTY / TRIP (Reason) c) Battery Low d) Static by-pass ON le) Over temperature f Earth leakage 25, JAlarm i) Low battery alarm to be provided i) % load ii) Failure of inverter iv) Main failure / Load on battery alarm to be provided both should be audio visual 'v) Over temperature alarm in two stages. 1 stage : warning, Intermittent audio alarm 2 stage: Tripping, continuous audio visual and resettable, 26 Metering Digital panel meter of LOD display system to indicate the folowing i) A.C. voltage : Inpu/Output i) A.C. current: Input/Output or % load ii) D.C. battery voltage iv) D.C. charging discharging current 1) Frequency Input/Output Battery set |A. SMF batteries (to be installed in ventlatedi/cooled rooms only) i) Complete with self standing cubical or cabinate i) Make like: Exide / Panasonic, CSB, Numeric | Amraraja, Rocket / Max New, U-Plus, AMCO best, HBL. i) Note: Only valve regulated lead acid (VRLA) type SMF batteries of 20 HR rated capacity electrolyte in paste form are acceptable. Any other type including calcium batteries are not acceptable. Tubular batteries {to be installed in entilated room with exhaust fan is required) i) Maintainable but regular topping necessary i) Complete with stand il) Make lke : Exide, Southern Batteries, Kirloskar, AMCO- insta power |toxva Minimum VAH required as per details as under: UPS Capacity Annexure-IV PRICE BID (rates to be quoted for states of Bihar and Jharkhand separately) 1. RATE CONTRACT FOR 1 YEAR FOR PROCUREMENT OF (A) UPS WITH BATTERIES, (B) BATTERIES AND (C) FOR COMPREHENSIVE AMC OF OLD UPS WHICH ARE INSTALLED BEFORE 13/0CT/2015 BIHAR Name of Manufacturer / Vendor: Address, Email, Telephone No. , Fax No.: Rate quoted shor site including .. (A) SUPPLY OF UPS WITH BATTERY BANK ITEM. S. Feapacity of UPS & mount fAmountfor faggregate TOTAL uy Back No. [SMF Battery Back-up jor attery Bank AMC costof [COSTFOR — Jalue of old ime PSS |Rs.) IPSS for 4 TERMINI [UPS without Rs.) ars after. = NGLI ateries B) warranty Rs.) (A) eriod of 3. fD)-AtB+C ears (RS.) (Cc) }2 KVA, 1 Hr. Battery Back u 1*Yr- 1. mention 2 Yr 1 pote AH: 3 Yr- 0. of batterie a yr. Total VA, 1 Battery Back up ast Yr |. mention 2nd Ye- Jo. of batteries: 4th Yr- Total- IO KVA, 1 Hr Battery Back up 9. mention ast Jo. of batteries: ard Yr 4th Yr- Tota L Place: Date: Signature with Seal (8) SUPPLY OF BATTERIES ONLY IN BIHAR : Name of Manufacturer / Vendor: ‘Address, Email, Telephone No. , Fax No.: Rate quoted should be all-inclusive for delivery, installation and commissioning at site including taxes..Net Unit Amount (C) will be considered for determining L1. [SNo ] Capacity of Battery (SMF Type) nit Rate (RS) (A) nit Buy Back te (Rs.) (8) let unit Amount Rs.) (C)=A-B 2 Volt, 42 AH fake: fi2 Volt, 65 AH lake: f2 Vor, 100 AH MAKE ss f2 Vor, 150 AH Make! ssn Rate quoted should be inclusive of all Date: Place: Signature with seal C) RATE CONTRACT FOR COMPREHENSIVE AMC OF OLD UPS WHICH ARE INSTALLED 1 /1KVAUPS WITH BATTERY 2 | 2KVAUPS WITH BATTERY Pl ps ere eee 4 5KVA UPS WITH BATTERY (5 7.5KVAUPSWITH BATTERY — | le 40KVA UPS WITH BATTERY | BEFORE 13/OCT/2015 IN STATE OF BIHAR .N. Capacity of UPS with battery | Aggregate AMC cost for 1Yr. (Rs.) (rates to be quoted for states of Bihar and Jharkhand separately) 41. RATE CONTRACT FOR 1 YEAR FOR PROCUREMENT OF (A) UPS WITH BATTERIES, (B) BATTERIES AND (C) FOR COMPREHENSIVE AMC. OF OLD UPS WHICH ARE INSTALLED BEFORE 13/0CT/2015 JHARKHAND. Name of Manufacturer / Vendor: Address, Email, Telephone No. , Fax No.: Rate quoted shoul at site including .. (8) SUPPLY OF UPS WITH BATTERY BANK ITEM S. Capacity of UPS & mount Amount for — Aggregate ‘OTAL jay Back No. SMF Battery Back-up for sattery Bank JAMC cost of OST FOR jalue of old time PSS Rs.) IPSS for 4 TERMINI PS without Rs.) ars after IGL1 atteries 8) warranty Rs.) (A) eriod of 3. {D)FA*B+C eae (Rs) () KVA, 1 Hr. Battery Back up| Tyr 1. mention 2 Vr 1 Battery AH:.. 3" Yr lo. of batter an yr Total i= THr. Battery Back up ie 1st r= |. mention 2nd Vr- 2 Battery AH encrnurnnne 3rd Yr- Jo. of batteries: ath Yr- Total- (0 KVA, 1 Ar. Battery Back up =| |. mention astYr- Jo. of batteries: 3rd Yr- 4th Yr- Total- Place: Signature with Seal Date: (B) SUPPLY OF BATTERIES ONLY IN JHARKHAND: Name of Manufacturer / Vendor: Address, Email, Telephone No. , Fax No.: Rate quoted should be all-inclusive for delivery, installation and commissioning at site including taxes. Net Unit Amount (C) will be considered for determining L1. S.No Capacity of Battery (SMF init Rate (Rs.) pat Buy Back let unit Amount Type) i) ‘ale (Rs) ) 8) CAB 2 Volt, 42 AH lake: 72 Volt, 65 AH I kB cs 2 Volt, 100 AH Make: 2 Vor, 150 AH Make: Rate quoted should be inclusive of all . Date: Place: Signature with seal (C) RATE CONTRACT FOR COMPREHENSIVE AMC OF OLD UPS WHICH ARE INSTALLED BEFORE 13/0CT/2015 IN STATE OF JHARKHAND S1N. Capacity of UPS with battery Aggregate AMC cost for 1Yr.(Rs.) (1 1KVA UPS WITH BATTERY 2 | 2KVAUPS WITH BATTERY 3 |SKVAUPS WITH BATTERY 4 | SKVAUPS WITH BATTERY .SKVAUPSWITHBATTERY 6 — 10KVA UPS WITH BATTERY

You might also like