Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

NO NAMA ALAT & SPESIFIKASI

1. NON INVASIVE CARDIAC OUTPUT / CARDIOVASCULAR MONITOR


TYPE : AESCULON
MERK : OSYPKA - GERMANY

Spesifikasi :
PARAMETER
Blood Flow
- SV/SI : Stroke Volume / Stroke Index
- HR : Heart Rate
- CO/CI : Cardiac Output / Cardiac Index

Vascular System
- NIBP : Non-invasive Blood Pressure
- SVR/SVRI : Systemic Vascular Resistance/ SVR-
Index based on input of MAP and CVP
- SSVR/SSVRI : Stroke Systemic Vascular Resistance / SSVR-Index

Contractility
TM
- ICON : Index of Contractility
TM
- VIC : Variation of Index of Contractility
- LCW/LCWI : Left Cardiac Work based on input of Wedge Pressure (PAOP)
- LSW / LSWI : Left Stroke Work
- STR : Systolic Time Ratio (PEP/LVET)
- CPI : Cardiac Performance Index

Fluid Status
- TFC : Thoracic Fluid Content
- SVV : Stroke Volume Variation
- FTC : Flow Time Corrected

Oxygen Status (Pulse Oximetry)


- SpO² : Oxygen Saturation
- PI/PI Change : Perfusion Index / PI Percent Change
- Desat Idx : Desaturation Index
- Do² / DO²I : Oxygen Delivery / DO2-Index based on input of
: Hemoglobin and SpO²

AESCULON® Features

- 12" High resolution color display with touch operation


- Integrated iControl™ software
- Rechargeable battery backup for 20 min. of operation
- Patient data are recorded beat for review and data export
- USB Interface for convenient backup of patient data and printing
- PDF Status reports can be saved and printed

Technical Data
- Measurement Menthod : Electrical Cardiometry (EC)
: Bio-Impedance

Page 1
NO NAMA ALAT & SPESIFIKASI
- Measurement Current : ≤ 2.0 mA RMS/50 kHz
- ECG : 15 … 300 bpm
- Non-Invasive Blood Pressure (NIBP) : Oscillatoric
systolic : 40 mm Hg … 260 mm Hg
diastolic : 25 mm Hg … 200 mm Hg
- Oxygen Saturation (SpO2) : 1% … 100%
- AC Input : 100 … 240 VAC, 47 … 63 Hz
- Power Consumption : max. 100 VA
- Internal Battery : NiMH. Cap. > 20 min
- Display : 12" color TFT Touch screen
- Enclosure Dimensions
Height x Width x Depth : 293 mm x 310 mm x185 mm
- Weight 6 Kg
- Classification According to EC-Directive : Class IIa
Protection Type : Class I equipment (Type BF)
Standard Complience : IEC 60601-1, IEC 60601-1-2 and other

Accessories Included :
- AC Power Cord 1 Pc
- Grounding Wire 1 Pc
- PC Cable 1 Pc
- EV Patient Cable 1 Pc
- SpO2 Sensor 1 Pc
- Arm Cuff Adult 1 Pc
- Arm Cuff Adult (Large) 1 Pc
- Arm Cuff Pediatric 1 Pc
- Cuff Hose 1 Pc
- Manual Book 1 Pc
- Carrying Hardcase w / Foam Inlet 1 Unit
- Arm Cuff Neonates 1 pc

Page 2