Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Laboratory California Bearing Ratio Test

As per IS 2720- Part 31 (1990, Reaff. 2015)


Client : Acotech Consultants Pvt.Ltd.
Site : AMC CC Road From Boudhwada to Mira Swaroop Laxminagar
Sample ID : TC5428191000000203F

Test: CBR Sample DS


Type of test : Soaked Proving Ring constant: 2.96

Sr. Penetration Proving ring Test Load


350
No. mm Divisions Kg
325
0 0.00 0.00 0.00
1 0.50 10.00 29.60 300

2 1.00 14.00 41.44 275


3 1.50 18.00 53.28 250
4 2.00 22.00 65.12
225
5 2.50 26.00 76.96
200
Load, kg

6 3.00 31.00 91.76


7 3.50 36.00 106.56 175
8 4.00 42.00 124.32 150
9 4.50 49.00 145.04
125
10 5.00 52.00 153.92
11 6.00 64.00 189.44 100

12 7.00 73.00 216.08 75


13 8.00 81.00 239.76 50
14 9.00 90.00 266.40
25
15 10.00 104.00 307.84
16 12.50 113.00 334.48 0
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0
Penetration, mm

Test Results :

LOAD AT 2.5MM PENETRATION 76.96


LOAD AT 5 MM PENETRATION 153.92
C.B.R AT 2.5MM PENETRATION, % 5.62
C.B.R. AT 5 MM PENETRATION, % 7.49

You might also like