Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Laboratory California Bearing Ratio Test

As per IS 2720- Part 31 (1990, Reaff. 2015)


Client : Acotech Consultants Pvt.Ltd.
Site : AMC CC Road at Gosavi Society Plot 253 to Gajanan Krupa Plot No. 246
Sample ID TC5428191000000201F

Test: CBR Sample DS


Type of test : Soaked Proving Ring constant: 2.96

Sr. Penetration Proving ring Test Load


700
No. mm Divisions Kg
650
0 0.00 0.00 0.00
1 0.50 6.00 17.76 600

2 1.00 13.00 38.48 550


3 1.50 22.00 65.12 500
4 2.00 26.00 76.96
450
5 2.50 32.00 94.72
400
Load, kg

6 3.00 41.00 121.36


7 3.50 47.00 139.12 350
8 4.00 54.00 159.84 300
9 4.50 57.00 168.72
250
10 5.00 61.00 180.56
11 6.00 70.00 207.20 200

12 7.00 92.00 272.32 150


13 8.00 110.00 325.60 100
14 9.00 126.00 372.96
50
15 10.00 135.00 399.60
16 12.50 151.00 446.96 0
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0
Penetration, mm

Test Results :

LOAD AT 2.5MM PENETRATION 94.72


LOAD AT 5 MM PENETRATION 180.56
C.B.R AT 2.5MM PENETRATION, % 6.91
C.B.R. AT 5 MM PENETRATION, % 8.79