Professional Documents
Culture Documents
Acelerometros 200150,20155,200157
Acelerometros 200150,20155,200157
Acelerometros 200150,20155,200157
Application Advisories
1. Use of the 200155 and 200157 Accelerometers with 1900
monitors or with TIMs other than those listed in Table 1 will
result in false readings.
2. Operating the transducers outside their specified limits will
result in false readings or loss of machine monitoring.
3. The maximum allowed cable length for use with the 200155 is
50 feet.
4. 20015x accelerometers may be installed in a Class I, Zone 0
application without a barrier, if they are being used with the
wSIM.
Page 1 of 18
Table 1: 20015x Accelerometer Applications
Standard Acceleration-to-Velocity
200150 General application
channel type (-01)
Application Advisory
If you plan to use housing measurements for overall machinery
protection, consider the usefulness of the measurement for each
application. Most common machine malfunctions (imbalance,
misalignment, etc.) originate at the rotor and cause an increase
(or at least a change) in rotor vibration. For the housing
measurement alone to be effective for overall machine
protection, the installation must faithfully transmit a significant
amount of rotor vibration to the bearing housing or machine
casing, or more specifically, to the mounting location of the
transducer.
Page 2 of 18
Specifications Settling Time
(Within 5% of
All specifications are at +25 ºC (+77 ºF), unless Bias)
otherwise specified.
See Table 4.
Electrical Table 4: Measurement Ranges
Sensitivity @ 80
Hz (± 12%) Accelerometer Settling Time (ms)
±2%
Electrical
Transverse
Isolation
Sensitivity
600 Vrms
≤7%
Page 3 of 18
Environmental Housing and
connector
Axial Shock material
Limit 200150
49,050 m/s2 pk (5,000 g pk) 316L stainless steel
Temperature 200155
Range
316L stainless steel
-40 ºC to +105 ºC (-40 ºF to +221
ºF) 200157
Sensing Seal
Element Connectors provide an IP67 seal
Ceramic to transducers and mating
hardware. Connectors are
Sensing molded to the cable. The addition
Geometry of DC4 electrical insulating
Shear compound in the connectors
provides additional protection
against moisture during a thermal
shock.
Page 4 of 18
Minimum Bend Hazardous Area Approvals
Radius Multiple approvals for hazardous areas certified by
200151 Canadian Standards Association (CSA) in North
America and LCIE in Europe.
63.5 mm (2.5 in)
200152 North American
Page 5 of 18
19 Quick-Set XDCR adapter,
Ordering Information 1-inch hex stud
20 3/8-24 thread, 1 magnetic
General Purpose Trendmaster 2000 or Trendmaster Pro mount base
Accelerometer 21 3/8-24 outer diameter to M6x1
200150-AXX inner diameter 1-3/8 inch
hex plate stud
Low Frequency Trendmaster Pro Accelerometer 22 3/8-24 to M8x1.25 1-3/8 inch
hex plate stud
200155-AXX 23 3/8-24 to M16x2.0 1-3/8 inch
Enveloping Trendmaster Pro Accelerometer hex plate stud
200157-AXX Note: Adhesive studs (Options 0 1 and 2 0) are sold in kits
containing frames to hold the studs to the
Refer to Table 6 for detailed specifications. substrate while the adhesive cures. The kit also
contains a packet of acrylic adhesive and materials
A: Mounting Stud Option
to mix its 2 components and provides a scouring
00 No mounting stud provided
pad and alcohol wipe to prepare the mounting
01 3/8-24 thread, 2 adhesive
surface.
mount frames with
adhesive
02 3/8-24 to 3/8-24 UNF 1-3/8
inch hex plate stud
03 3/8-24 to 1/2-20 UNF 1-3/8
inch hex plate stud
04 3/8-24 to 1/4 NPT 1-3/8 inch
hex plate stud
05 3/8-24 to 1/4-28 UNF 1-3/8 Application Advisory
inch hex plate stud
06 3/8-24 to 1/4 NPT, 3/4 inch hex Using adhesives and magnetic mounts will
stud attenuate high frequency signals that may
07 3/8-24 to 3/8 NPT, 3/4 inch hex be present.
stud
08 3/8-24 to 1/2 NPT 1 inch hex
stud Accelerometer Interface Standard Cable, Connectors on
09 3/8-24 to 3/4 NPT, 1-1/4 inch Both Ends
hex stud 200151-AXX-BXX-CXX
10 3/8-24 to 1 NPT, 1-3/8 inch hex
A: Cable length
stud
20 2.0 meters
11 3/8-24 to 1-1/4 NPT, 1-3/4 inch
40 4.0 meters
hex stud
60 6.0 meters
12 3/8-24 to 1/4-20 UNC, 3/4 inch
B: Armor option
hex stud
02 Blue cable without armor
13 3/8-24 to 5/16-18 UNC, 3/4
03 Blue cable with armor
inch hex stud
C: Coupling nut
14 3/8-24 to 3/8-24 UNF, 3/4 inch
00 Standard coupling nut (see
hex stud
Figure 9)
15 3/8-24 to 3/8-16 UNC, 3/4 inch
02 Nylon coupling nut
hex stud
10 Enhanced coupling nut. This
16 3/8-24 to 1/2-13 UNC, 3/4 inch
option provides a better
hex stud
grip for tightening the cable
17 3/8-24 to 3/8-16 UNC 1-3/8
to the accelerometer and is
inch hex plate stud
provided on both ends of
18 3/8-24 to M8x1 1-3/8 inch hex
the cable (see Figure 11).
plate stud
Page 6 of 18
Accelerometer Interface Standard Cable, Connector on 141574-01
Accelerometer End Only
200100 Acceleration-to-Velocity
200152-AXX-BXX flexiTIM Module datasheet.
A: Cable length 137230-01
04 4.0 meters
15 15 meters FlexiTIM Operation Manual.
25 25 meters 190125-01
B: Coupling nut
00 Standard coupling nut (see 1900/25 Vibration Monitor
Figure 10) Operation and Maintenance
10 Enhanced coupling nut. This Manual.
option provides a better
141485-01
grip for tightening the cable
to the accelerometer and is 1900/25 Vibration Monitor
provided on the datasheet.
accelerometer end only (see
190127-01
Figure 12).
1900/27 Vibration Monitor
Operation and Maintenance
Manual.
Accessories
164985-01 141486-01
Page 7 of 18
Mechanical Specifications, Graphs, and Figures
Note: All dimensions shown in millimeters (inches) except as noted.
Table 6: Mounting Stud Specifications
Stud Length Recommended Torque Replacement
Option “A” Maximum Torque in N•m (in•lbf) Notes
in mm (in) in N•m (in•lbf) Part Number
Page 8 of 18
6.35 (0.25)
1. 3/8-24 UNF 2A
2. Stud length
Figure 1: Hex Plate Stud for “A” Options 02, 03, 05, 17, 18, and 23.
6.35 (0.25)
2
1. 3/8-24 UNF A
2. Stud length
Figure 2: Hex Plate Stud for “A” Option 04
6.4 (0.25)
2
1. 3/8-24 UNF 2A
2. Stud length
Figure 3: Hex Stud for “A” Options 06 Through 11
Page 9 of 18
1
2
19.1 (0.75)
1. 3/8-24 UNF 2A
2. Stud length
Figure 4: Hex Stud for “A” Options 12 Through 17
6.4 15.9
[0.250] [0.63] 2
1. 3/8-24 UNF 2A
2. Stud length
Figure 5: Quick-Set XDCR Adapter
6.4
[0.250] 1
1. 3/8-24 UNF 2A
Figure 6: Magnetic Mount Base
Page 10 of 18
1
1. 4
U 2
5.97N(0.235)
F
2A outer diameter
2. M6 x 1 inner diameter
1. 3/8-24 UNF 2A
2. M8 x 1,25
3. Stud length
Page 11 of 18
1
Page 12 of 18
Figure 13: Housing Cable Adapter (Part Number 142485-01)
Page 13 of 18
2
1 3
6
7
1. Top view
2. 19.1 mm (0.750 in) across corners
3. 11/16-inch hexagonal
4. Side view
5. 1/2-20 UNC-2A 5-pin connector
6. 3/8-24 UNF-2B threads, 7.1 mm (0.28 in) deep, minimum
7. 17.0 mm (0.67 in) diameter, typical
Figure 16: Accelerometer Dimensional Drawing
Page 14 of 18
200150
25
20
15
10
db
-5
-10
1 10 100 1000 10000 100000
Frequency
200150
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 15 of 18
200155
25
20
15
db
10
-5
1 10 100 1000 10000 100000
Frequency
200155
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 16 of 18
200157
25
20
15
db
10
-5
1 10 100 1000 10000 100000
Frequency
200157
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 17 of 18
20015X - Sensitivity vs. Temperature
120.0
100.0
80.0
Sensitivity (mV/g)
60.0
40.0
20.0
0.0
-40 -20 0 20 40 60 80 100 120 140 160 180 200 220
Tem perature (°F)
* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company.
Page 18 of 18