Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SY^2 PARAMETERS FOR STRUCTURAL DESIGN AND CONSTRUCTION BASED ON

ACI 318-11 DEVELOPMENT AND SPLICES OF REINFORCEMENT fc' =3000 PSI (20.7 MPa)
BENT and LExtension DEVELOPMENT LENGTH IN TENSION
DEVELOPMENT DEVELOPMENT (mm) SPLICE LENGTH FOR Ldt(mm) STANDARD HOOK GEOMETRY
DEFORMED BAR  LENGTH FOR LENGTH FOR REBAR UNDER
(mm) STRAIGHT BARS HOOKED BARS COMPRESSION
FOR STIRRUPS,TIES AND
BEAM/GIRDER COLUMN HOOPS UNIT WT.
Ld (mm) Ldh (mm) Lsc (mm) LAP
90° HOOK 180° HOOK (kg/m)
CLASS BOTTOM TIED /
TOP BAR
BAR SPIRAL

PRIMARY REINFORCEMENT GRADE 40 (GRADE 280 ) 90° HOOK 135° HOOK

A 380 300
10 370 150 180 130 200 300 120 120 0.617
B 500 380
A 460 360
12 440 180 220 140 240 360 130 130 0.888
B 600 460

PRIMARY REINFORCEMENT GRADE 60 (GRADE 415 ) 90° HOOK 135° HOOK

A 690 530
12 660 270 220 140 360 530 130 130 0.888
B 890 690
A 920 710
16 880 360 290 160 480 710 160 160 1.578
B 1190 920
A 1140 880
20 1100 440 360 200 600 880 320 240 2.466
B 1490 1140
A 1790 1370
25 1370 550 450 250 750 1370 400 300 3.853
B 2320 1790
A 2000 1540
28 1540 620 560 340 840 1540 4.834
B 2600 2000
A 2280 1760
32 1760 710 640 390 960 1760 6.313
B 2970 2280
A 2570 1980
36 1980 790 720 440 1080 1980 7.990
B 3340 2570
NOTES:
1. DEVELOPMENT LENGTH OF INDIVIDUAL BARS WITHIN A BUNDLE IN TENSION OR COMPRESSION, SHALL BE THAT FOR INDIVIDUAL BARS,INCREASED 20% FOR
THREE-BUNDLED BARS AND 33% FOR FOUR BUNDLED BARS. INDIVIDUAL BAR SPLICES WITHIN A BUNDLE SHALL NOT OVERLAP. ENTIRE BUNDLES SHALL NOT BE SPLICED.
2. FOR COLUMNS AT ANY LEVEL, NO MORE THAN ALTERNATE BARS SHOULD BE SPLICED, NOT MORE THAN 33% OF THE BARS SHALL BE SPLICED WITHIN
THE REQUIRED LAP LENGTH. Research and Development
CONTROLLED COPY
Prepared By: JAZ A.T

3. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 300 mm DEPTH OF CONCRETE CAST BELOW REINFORCEMENT.

4. LAP SPLICE SHALL BE "CLASS B" TENSION LAP SPLICE IF MORE THAN ONE HALF OF THE BARS WERE SPLICED AT ANY SECTION, WHILE
MARCH 2015
"CLASS A" TENSION SPLICE IF HALF OR FEWER THAN HALF OF BARS WERE SPLICED.

Prepared By: JAZ A.T