Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE C* 30 PUMP
For contact details -
50 CC PERFORMANCE
55
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER C2021 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
50MP10
2 OPEN METAL 214 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
GLAND SEAL PUMP
WE RESERVE THE RIGHT TO MODIFY OR DELETE
Printed
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL June 2004
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM MIN PASSAGE SIZE

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 2700 48mm
SPHERE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
2700
r/min 30% 35%
40%
43%
44%
50 2500 45%

46%
2300
40 45%
44%
2100 43%
H (m)

Test Date: June 2004


30
1900

1700
20
1500

Reference Test: MP062


10

0 5 10 15 20 25
Q (l/sec)
8
NPSH (m)

6
2700rpm

4
2500rpm

2300rpm
Revision: 0

2
1900rpm
1700rpm
1500rpm
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE C* 30 PUMP
For contact details -
50 CC 55 PERFORMANCE
visit www.warman.co.za CURVE
REFERENCE
TYPE
CASING
IMPELLER C2147
WPG
MP VANES TYPE MAT’L VANE O MAT’L
50MP30
5 CLOSED METAL 214 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
25 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 3170 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100

3170 30% 40%


90
50%
55%
60%
3000 62%
80
63.5%
62%
70
2800
60%

60
2600
H (m)

Test Date: June 2004


2400
50

2200
40
2000

30 1800

1600
20
1400
Reference Test: MP023

1200
10

0
0 5 10 15 20 25 30 35 40 45 50

Q (l/sec)
25
3170
20
r/min
NPSH (m)

15

10
Revision: 0

5 1200
0 r/min
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE C* 30 PUMP
For contact details -
50
PERFORMANCE
CC 55
visit www.warman.co.za CURVE
REFERENCE
TYPE
IMPELLER C2147 CASING
WPG
MP VANES
5
TYPE
CLOSED
MAT’L
POLYURETHANE
VANE O
215
MAT’L
METAL 50MP32
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
21 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 2300 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

50 40% 45%
2300 50%
r/min 55%
60%
45

2100 62%
40

60%
35
1900

30
H (m)

Test Date: June 2004


1700

25

1500
20

1300
15

10
Reference Test: MP026

0
0 5 10 15 20 25 30

Q (l/sec)
6

2300
4
r/min
NPSH (m)

1300
2
r/min
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE C* 30 PUMP
For contact details -
50
CC PERFORMANCE
55
visit www.warman.co.za CURVE
REFERENCE
TYPE
C2058 CASING
IMPELLER
WPG
MP VANES TYPE MAT’L VANE O MAT’L
50MP50
6 CLOSED METAL 225 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
25 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 3100 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100

90 3100 40%
r/min 50%
55%
60%
80
2900
65%

67%
70
2700
65%
60 2500
H (m)

Test Date: June 2004


60%

2300
50

2100
40

1900
30
1700

1500
20
1300
Reference Test: MP065

1100
10

0
0 5 10 15 20 25 30 35 40 45 50

Q (l/sec)
16
3100
r/min
12
NPSH (m)

8
Revision: 0

4
1100
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE CAM 30 PUMP
For contact details -
75 CCAM PERFORMANCE
55
visit www.warman.co.za CURVE
D* 60 REFERENCE
TYPE DD 110
IMPELLER D3021X CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
75MP10
2 OPEN METAL 248 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
50mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 2100 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60

2100 rpm

50 30%
35% 40%
42%
45% 47%
1900 rpm

40

1700 rpm 47%


H (m)

Test Date: June 2004


30
1500 rpm

1300 rpm
20

1100 rpm

10 900 rpm

700 rpm
500 rpm Reference Test: MP034

0
0 10 20 30 40 50 60 70 80

Q (l/sec)
10
2100rpm
NPSH (m)

6
1700rpm

4
1300rpm
2
Revision: 0

900rpm
500rpm
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE CAM 30 PUMP
For contact details -
75 CCAM 55 PERFORMANCE

D* 60 visit www.warman.co.za CURVE


REFERENCE
TYPE DD 110
IMPELLER D3052 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
75MP16
3 OPEN METAL 240 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
32mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 2300 SPHERE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60
2200 35% 40% 45%
r/min 50%
55%
50
2000 56.5%
55%

40
1800
H (m)

Test Date: June 2004


1600
30

1400

20
1200

1000
10
Reference Test: MP018

0
0 10 20 30 40 50 60
Q (l/sec)
8

2200rpm
6

1800rpm
4
NPSH (m)

1400rpm
2
Revision: 0

1000rpm

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE CAM 30 PUMP
For contact details -
75
PERFORMANCE
CCAM 55
D* 60
visit www.warman.co.za CURVE
REFERENCE
TYPE DD 110
IMPELLER D3147 CASING
MP VANES TYPE MAT’L VANE O MAT’L WPG
5 CLOSED METAL 245 METAL 75MP30
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMTION MAY INCREAS BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
36 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 2750 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

2750 30% 40%


r/min 50%
80 60%
2600 65%

70

2400 68%

60
65%
2200
H (m)

Test Date: June 2004


50

2000

40
1800

30 1600

1400
20
1200
Reference Test: MP013

1000
10

0 90
0 10 20 30 40 50 60 70 80

Q (l/sec)
20

16
2750
r/min
NPSH (m)

12

8
Revision: 0

4 1000
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE CAM 30 PUMP
For contact details -
75
PERFORMANCE
CCAM 55
D* 60
visit www.warman.co.za CURVE
REFERENCE
TYPE DD 110
IMPELLER D3147 CASING
MP VANES TYPE MAT’L VANE O MAT’L WPG
5 CLOSED POLYURETHANE 245 METAL 75MP32
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
28 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1800 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

40

1800 30% 40% 50%


35
60%
r/min 65%

68%
30

1600
65%
25
60%
H (m)

Test Date: June 2004


1400
20

1200
15

1000
10

800
Reference Test: MP037

0
0 10 20 30 40 50 60

Q (l/sec)
12

1800
r/min
8
NPSH (m)

4
Revision: 0

800
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100
PERFORMANCE
DDAM 110
E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4058 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP50
6 CLOSED METAL 385 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
40 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1800 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100

1800 40% 50%


90 60%
r/min
70%
1700 75%
80

77%
1600
70
75%
1500
60
H (m)

Test Date: June 2004


1400

50
1300

1200
40

1100

30
1000
900
20
800
Reference Test: MP047

10

0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
15
1800
r/min
12
NPSH (m)

6
Revision: 0

3 800
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100 DDAM 110 PERFORMANCE

E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4021 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP10
2 OPEN METAL 397 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
63 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1600 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

80

70
1600
r/min

60
35%
40%
45%
1400 50%
50
54%
56%
54%
H (m)

50%

Test Date: June 2004


40
1200 45%

30
1000

20
800

600
10

Reference Test: MP040

0
0 20 40 60 80 100 120
Q (l/sec)

16

12
1600rpm
8
NPSH (m)

4
Revision: 0

600rpm
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100
PERFORMANCE
DDAM 110
E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4147 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP30
5 CLOSED METAL 365 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
51 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1830 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

90

1800 40% 50%


80 r/min 60%
65%
1700 68%
70

1600 70%

60
1500 68%
H (m)

Test Date: June 2004


1400
50

1300
40
1200

1100
30
1000

900
20
800
Reference Test: MP043

10

0 0 20 40 60 80 100 120 140 160


Q (l/sec)
16
1800
r/min
12
NPSH (m)

8
Revision: 0

4
800
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100
PERFORMANCE
DDAM 110
E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4147 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP32
5 CLOSED POLYURETHANE 365 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
33 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1350 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

50

1350 40%
r/min 50%
60%
1300 65%
70%
40

71%
1200
70%

1100
30
H (m)

Test Date: June 2004


65%

1000

900
20

800

10 Reference Test: MP053

0
0 20 40 60 80 100 120

Q (l/sec)
8

6
1350
NPSH (m)

r/min
4
800
r/min
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100
PERFORMANCE
DDAM 110
E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4127 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP33
5 OPEN POLYURETHANE 365 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
33 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1350 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60

1350 rpm
40%
50 45%
1300 rpm 50%
55%
60%

1200 rpm 62%


40
60%
1100 rpm
H (m)

Test Date: June 2004


30
1000 rpm

900 rpm

20
800 rpm

10

Reference Test: MP056

0
0 40 80 120 160

Q (l/sec)
10

8
1350 rpm
NPSH (m)

6
1100 rpm

4
800 rpm

2
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE DAM 60 PUMP
For contact details -
100
PERFORMANCE
DDAM 110
E* 120
visit www.warman.co.za CURVE
REFERENCE
TYPE EE 225
IMPELLER E4058 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
100MP50
6 CLOSED METAL 385 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
40 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1800 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100

1800 40% 50%


90 60%
r/min
70%
1700 75%
80

77%
1600
70
75%
1500
60
H (m)

Test Date: June 2004


1400

50
1300

1200
40

1100

30
1000
900
20
800
Reference Test: MP047

10

0
0 20 40 60 80 100 120 140 160 180
Q (l/sec)
15
1800
r/min
12
NPSH (m)

6
Revision: 0

3 800
r/min
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150 225 PERFORMANCE
EEAM
F* 260 visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
IMPELLER F6021 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP10
2 OPEN METAL 509 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
63 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1000 SPHERE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60

1000
r/min
50
30%
35%
40%
43%
900 46%
48%
49%
40
48%
45%
800
H (m)

Test Date: June 2004


30

700

20
600

500
10
400

Reference Test: MP021

0
0 20 40 60 80 100 120 140 160 180 200

Q (l/sec)
6
1000rpm

4
800rpm
NPSH (m)

2
600rpm
Revision: 0

400rpm
0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150 225 PERFORMANCE
EEAM
F* 260
visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
F6136
IMPELLER CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP15
3 CLOSED METAL 510 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
55 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1200 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

80

1200
70 r/min
30%
35% 40% 45%
50% 55%
60
1100 60%
62.3%

50
1000
H (m)

Test Date: June 2004


40 900

800
30

700

20

10
Reference Test: MP028

0
0 20 40 60 80 100 120 140 160 180 200

Q (l/sec)

16

1200rpm
12

8
NPSH (m)

4 700rpm
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150
EEAM 225 PERFORMANCE

F* 260 visit www.warman.co.za CURVE


REFERENCE
TYPE FF 425
IMPELLER F6145 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP26
4 CLOSED METAL 510 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
50 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1000 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
55

1000
50 r/min 40% 50%
55%
60%
45 65%

900 68.5%
40

35
800
H (m)

30

Test Date: June 2004


25 700

20
600

15
500

10
400

5
Reference Test: MP059

0
0 20 40 60 80 100 120 140 160 180 200
Q (l/sec)
10

8
1000rpm
6
NPSH (m)

2
Revision: 0

400rpm

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150 EEAM PERFORMANCE
225
F* 260
visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
IMPELLER F6147 CASING
MP VANES TYPE MAT’L VANE O MAT’L WPG
5 CLOSED METAL 510 METAL 150MP30
Printed
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
GLAND SEAL PUMP
WE RESERVE THE RIGHT TO MODIFY OR DELETE
June 2004
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
63 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1300 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.
90

80 1300 rpm 40% 45% 50% 55%


60%
65%

70 1200 rpm 72%

70%
60
1100 rpm

50 1000 rpm
H (m)

Test Date: June 2004


40 900 rpm

800 rpm
30

700 rpm

20
600 rpm

500 rpm
10
Reference Test: MP001

0
0 50 100 150 200 250 300
Q (l/sec)
16
1300rpm

12

8
NPSH (m)

4
Revision: 0

500rpm

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EE 120 PUMP
For contact details -
150 EEAM PERFORMANCE
225
F* 260
visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
IMPELLER F6147 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP32
5 CLOSED POLYURETHANE 510 METAL
Printed
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
GLAND SEAL PUMP
WE RESERVE THE RIGHT TO MODIFY OR DELETE
June 2004
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
59 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1000 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

60

1000 rpm 40% 50% 55%


65%
50
68%
900 rpm 65%

40

800 rpm
H (m)

Test Date: June 2004


30
700 rpm

600 rpm
20

500 rpm

10

Reference Test: MP005

0
0 50 100 150 200 250

Q (l/sec)
16

12
1000rpm
8
NPSH (m)

4 500rpm
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150 EEAM PERFORMANCE
225
F* 260
visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
IMPELLER F6127 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP33
5 OPEN POLYURETHANE 510 METAL
Printed
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
GLAND SEAL PUMP
WE RESERVE THE RIGHT TO MODIFY OR DELETE
June 2004
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
65 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1300 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100 1300 rpm 40%45% 50%


55% 60%
68%
90
1200 rpm
80
60%

70 1100 rpm
55%

60 1000 rpm
H (m)

Test Date: June 2004


50
900 rpm

40 800 rpm

30 700 rpm

600 rpm
20
500 rpm
10 Reference Test: MP030

0
0 50 100 150 200 250 300 350 400
Q (l/sec)
16
1300 rpm
12

8
NPSH (m)

4 500 rpm
Revision: 0

0
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE EAM 120 PUMP
For contact details -
150 225 PERFORMANCE
EEAM
F* 260 visit www.warman.co.za CURVE
REFERENCE
TYPE FF 425
IMPELLER F6058 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
150MP50
6 CLOSED METAL 545 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD Printed
GLAND SEAL PUMP June 2004
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL
MIN PASSAGE SIZE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM
50 mm

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 1300 SPHERE

* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

100

1300 40% 50%


90 60%
r/min
70%

80 1200
75%

70
1100

60
H (m)

Test Date: June 2004


70%
1000

50

900

40
800

30
700

20
600 Reference Test: MP008

500

10

0
0 50 100 150 200 250 300 350 400

Q (l/sec)
20

16 1300
r/min
NPSH (m)

12

8
Revision: 0

4
500
0
r/min
Index Maintenance Manuals Technical Data Drawing Information

PUMP FRAME KW RATING


SIZE FAM 260 PUMP
For contact details -
250
FFAM 425 PERFORMANCE

G* 600 visit www.warman.co.za CURVE


REFERENCE
TYPE GG 900
IMPELLER FAM250145 or G250145 CASING
WPG
MP VANES TYPE MAT’L VANE O MAT’L
250MP26
4 CLOSED METAL 805 METAL
COPYRIGHT RESEARCH AND DEVELOPMENT PTY LTD
Printed
GLAND SEAL PUMP Oct 2005
WE RESERVE THE RIGHT TO MODIFY OR DELETE
IMPELLERS WITHOUT PRIOR NOTICE POWER CONSUMED MAY INCREASE BY 5% WITH CENTRIFUGAL SEAL

CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER (IN ACCORDANCE NORM MAX RPM MIN PASSAGE SIZE

Last Issue: None


WITH PUMP TESTING ISO9906-1999 GRADE 2 (IS02548 CLASS C)). FOR MEDIA OTHER
THAN WATER, CORRECTIONS MUST BE MADE FOR DENSITY, VISCOSITY AND/OR THE
PRESENCE AND EFFECTS OF SOLIDS 800 86mm
SPHERE
* Indicates standard frame size fitted, refer to Head Office for availability of frame sizes quoted, other than standard. Operating pumps over maximum speed refer to Head Office.
Rated kilowatts is the maximum that any particular bearing assembly can transmit and is not the maximum motor frame size that can be fitted to any particular bearing assembly.

80 50% 60%
800 65% 70%
r/min
75%
70 78%
83%
78%
700
60 75%

50
H (m)

600

40

Test Date:
500
30

400
20

300
10
Reference Test:

0
0 100 200 300 400 500 600 700 800
Q (l/sec)
12

10
800
8 r/min

4
Revision: 0

You might also like