MERCURY 50

Recuperated Gas Turbine Generator Set

Power Generation

General Specifications
Gas Turbine
• Mercury™50 Recuperated Gas Turbine • NEMA Class F Insulation with F Rise • Turbine Compressor Cleaning
• Industrial, Single-Shaft • Continuous Duty Rating Voltages: Systems
• 10-Stage Axial Compressor – 3300, 6600, 11,000 (50Hz) – On-Crank
– Variable Inlet Guide Vanes and – 4160, 6900, 12,470, 13,800V(60 – Portable Cleaning Tank*
Stators Hz) • Package Power
– Compression Ratio: 9.9:1 Package – 120VDC Battery/Charger System*
– Inlet Airflow: 39.2 lb/sec • Mechanical Construction • Turbotronic ® 4 On-skid Gas Turbine
(17.9 kg/sec) – Steel Base Frame with Drip Pans Control System
– Vertically Split Case and Generator Alignment – Combination Gas Turbine and
• Combustion Chamber, Annular Type – 316L Stainless Steel Piping Control System
– Ultra-Lean-Premix Combustion • Start System – Standard Display with Discrete Event
System – Direct Drive AC Motor with Log, Strip Chart, Historical Trend,
– 8 Fuel Injectors VFD Control Mainteneace Screen
– Single Torch Ignitor System • Package Electrical Certification – Vibration and Temperature Monitoring
• Proximity Probe Vibration Transducers – NEC, CSA Class 1, Group D, Div 2 – English Display Text and Labels
• Turbine • Fuel System – Spanish, Portuguese, German,
– 2-Stage, Reaction – Natural Gas French or Simplified Chinese
– Clockwise Rotation – Landfill Gas* Display Text and Labels*
• Bearings – Digester Gas* – Auxiliary and Remote Display/
– 2 Radial: Viscous Damped • Integrated Lube Oil System Control Terminals*
Roller Bearings – Main/Pre/Post Lube – Auto Synchronizing
– 1 Thrust/Radial: Viscous Damped PumpBackupLube Pump – KW Import Control
Split Inner Race Ball Bearing – Air and Oil Cooler – KVAR/Power Factor Control*
– Water/Oil Lube Oil Cooler* – ControlNet Redundant Media,
Recuperator
– Integral Lube Oil Tank Ethernet, Data Highway Plus or
• Primary Surface Type Modbus RS232C/422/485 Supervisory
– Lube Oil Tank Heater
– Simplex Lube Oil Filter Interface*
Main Reduction Drive – Heat Recovery Application Interface*
– Duplex Lube Oil Filters*
• Epicyclic – Oil Mist Eliminator – Multi-Unit Applications: Load Shed
– 1500 or 1800 rpm (50 or 60 Hz) – Vent Flame Trap Control, Import/Export or kW/KVAR
– Vibration Monitoring: Acceleration • Air Inlet and Exhaust Systems Control Panels*
Transducer – Carbon Steel – InSight System™ Equipment Health
Generator – Stainless Steel* Management
• 4 Pole, 3 Phase, 6 Wire, – Barrier Type Filters – Printer/Logger
Wye Connected, Synchronous with – Self-Cleaning Filters • Documentation
Permanent Magnet Exciter – Inlet and Exhaust Silencers – Drawings
• Available Construction Type: – Inlet Evaporative Cooler* – Quality Control Data Book
– Open Drip-Proof – Inlet Chiller Coils* – Test Reports
• Sleeve Bearings • Enclosure – Operation and Maintenance Manuals
• Vibration Monitoring: Velocity – Complete Package • Factory Testing of Turbine and Package
Transducers – Fire Detection and CO2 – Non-Dynamic
• Class F Temperature Rise Suppresion System – Dynamic
• Class B Temperature Rise*

* Option
MERCURY 50
Recuperated Gas Turbine Generator Set
Power Generation

Nominal Performance* Application Performance Available Power


5500
Output Power 4600 kWe Steam (Unfired) 6.0 tonnes/hr
(13,125 lb/hr)
Heat Rate 9350 kJ/kWe-hr 5000

(8865 Btu/kWe-hr) Steam (Fired) 47.1 tonnes/hr


1536 °C (2800°F) (103,865 lb/hr) 4500
Exhaust Flow 63 700 kg/hr

Power (kW)
Chilling (Absorp.) 5140 kW
(140,400 lb/hr) (1460 refrigeration tons)
4000

Exhaust Temperature 365°C 3500

(690°F)
3000

*ASSUMPTIONS 2500
0 10 20 30 40 50 60 70 80 90 100 110 120
Nominal rating – per ISO  Ambient Temperature (Deg F)
At 15°C (59°F), sea level DSM50PG_002M

No inlet/exhaust losses
Relative humidity 60%
Natural gas fuel with  
LHV = 35 MJ/Nm3 (940 Btu/scf)
Heat Rate Thermal Efficiency
11000 42.
No accessory losses
Engine efficiency: 38.5%   10500 40
(measured at generator terminals)
Heat Rate (Btu/kW-hr)

10000 38

Thermal Efficiency (%)


9500
36

9000
34

8500
32

8000
0 10 20 30 40 50 60 70 80 90 100 110 120 30.
Ambient Temperature (Deg F) 0 10 20 30 40 50 60 70 80 90 100 110 120
DSM50PG_004M
Ambient Temperature (Deg F)
DSM50PG_003M

Enclosure Access and Maintenance Space 3.4 m


(11’ 0”)
MINIMUM SPACE CLEARANCE REQUIRED FOR
ENCLOSURE ACCESS DOORS AND
GENERATOR ROUTINE OPERATION AND MAINTENANCE
3.4 m
REMOVAL
(11’ 3”) AREA

MINIMUM
CLEARANCE
3.2 m 4.0 m
REQUIRED
(10’ 5”) FOR (13’ 0”)
ENGINE REMOVAL

11.1 m 4.9 m
(36’ 6”) (16’ 0”)
Package Height: 3.7m (12’ 3”)
Package Weight: 45 700 kg (100,700 lb) DSM50PG-003C

Solar Turbines Incorporated


P.O. Box 85376
FOR MORE INFORMATION
San Diego, CA 92186-5376 U.S.A. Telephone: (+1) 619-544-5352
Caterpillar is a trademark of Caterpillar Inc. Telefax: (+1) 858-694-6715
Solar, Mercury and Turbotronic are trademarks of Solar Turbines Incorporated.
All other trademarks are the intellectual property of their respective companies.
email:powergen@solarturbines.com
Specifications subject to change without notice. Printed in U.S.A. Internet: www.solarturbines.com
© 2013 Solar Turbines Incorporated. All rights reserved.
DSM50PG/0113/EO

You might also like