ROOFING HANDBOOK Sarnafil® T

INFORMATION FOR THE PLANNING AND INSTALLATION OF


Sarnafil® T ROOF WATERPROOFING MEMBRANES
WORLDWIDE CONSTRUCTION TABLE OF CONTENTS
AND INDUSTRY SOLUTIONS
SikaRoof® Control Systems ....................................................... 89
SERVICE INFORMATION
Technology Overview Thermal Insulations ............................... 90
Sarnafil® – The Concept ...............................................................  8
Thermal Insulations.................................................................... 98
Sika Technical Roofing Experts.................................................... 9
Product Overview Vapour- Control Layers / Barriers .............. 100
Sika Roofing Application Technicians ........................................ 10
Vapour Control Layers ............................................................... 1 0 1
Building Information Modeling (BIM) Objects ........................... 11
Vapour Barriers .......................................................................... 102
Wind Load Calculations............................................................... 12
Vapour- Control Layers / Barriers Accessories ......................... 104
Computer Aided Design (CAD)
System Overview Fall Arrest Systems ..................................... 106
Detail Drawings and Packages.................................................... 13
Fall Arrest Systems ................................................................... 108
Roof Drainage .............................................................................. 14
Application Tools ....................................................................... 1 1 1
Guarantees................................................................................... 15
Proofen Performance – Durability of Sarnafil® T....................... 16
APPLICATION INSTRUCTIONS
PRODUCT INFORMATION Basics ......................................................................................... 1 1 6
Sarnafil® T ROOF WATERPROOFING MEMBRANES Mechanically Fastened Roof System........................................ 124
Material and Manufacturing ...................................................... 22 Gravel Ballasted Roof System................................................... 130
Inlays, Fleece- and Self Adhesive Film Backings ...................... 23 Inverted Roof System ...............................................................  134
Roof Design................................................................................. 24 Utility Roof System................................................................... 138
Color Chart................................................................................... 25 Green Roof System.................................................................... 142
Product Overview........................................................................ 26 Adhered Roof System................................................................ 146
External Fire Performance.......................................................... 28 Roof Refurbishment.................................................................. 1 51
Chemical Resistance................................................................... 32
Product Properties...................................................................... 34 STANDARD DETAILS
Sika’s history began in 1910 with the electrification of the Gotthard railway tunnels. The Swiss company founded by Kaspar Sarnafil® T ACCESSORIES
Winkler played a decisive role in this momentous project. A revolutionary new waterproofing mortar was developed, marking the Overview .................................................................................... 160
Detailing Membrane................................................................... 40
beginning of Sika’s global reputation for high quality. Layer Description........................................................................ 162
Metal Sheet / Coil....................................................................... 41
Parapet ...................................................................................... 164
Today the Sika Group is a leading global manufacturer of construction chemical products and systems as well as industrial Welding Preparation / Cleaners................................................. 42
Roof Edge Termination with Gutter.......................................... 168
sealants and adhesives. The Group’s core competencies – sealing, bonding, damping, reinforcing and protecting load-bearing Solvent Free Cleaners................................................................. 44
structures – have been enabling a wide range of applications in the construction sector and in industrial production for over 100 Upstand ..................................................................................... 172
Adhesives, Primers and Sealants .............................................. 46
years. The high-quality product range includes concrete admixtures, special mortars, sealants & adhesives, damping & reinforcing Skylight ...................................................................................... 176
materials, floor coating systems, sealing membranes and corrosion protection products. Prefabricated Products............................................................... 52
Roof Drain (Outlet) .................................................................... 180
Roof Drainage ............................................................................. 55
Sika annually produces a volume of roofing membrane that could cover the entire area of Manhattan. Scupper ...................................................................................... 184
Ancillary Components ................................................................ 60
More than 10,000 roofing contractors in over 85 countries are Sika-trained and certified, which ensures qualified installation. Overflow ..................................................................................... 188
Walkways .................................................................................... 63
Vent Pipe / Post ........................................................................ 192
All our customers – developers, building owners, architects, engineers, consultants and contractors – receive expert advice from Connection System..................................................................... 65
Gutter ......................................................................................... 196
our highly competent team. Building on a foundation of trust, we offer our experience and knowledge to provide recommenda- Fastening Products..................................................................... 67
tions and long-lasting solutions for any project you may have. Movement Joint ......................................................................... 198
Fastening Products – Tools ........................................................ 72
Fall Arrest Anchor .................................................................... 202
Roofing can be selected and designed to meet the specific technical requirements and budget of almost any roofing project. Our Roof Design................................................................................. 74
tailored solutions allow freedom of design and form, with no limitations on geometry or color, to meet the specific requirements Product Overview Felts and Glass Fleece.................................. 76
of any type of roof. Levelling- and Protection Layers ................................................ 77 SUSTAINABLE SOLUTIONS
Separation-, Levelling- and Protection Layer............................ 78 Responsible for the Future – Sika Roofing Solutions ............ 208
Separation- and Fire Protection Layer....................................... 79 More Value Less Impact ........................................................... 209
STRATEGIC SUCCESS THROUGH GLOBAL PRESENCE
Filter Layer .................................................................................. 80 The Sika Life Cycle Approach .................................................... 210
́ With subsidiaries in over 100 countries, Sika offers local presence worldwide
́ Sika operates over 300 production sites and sales locations Protection- and Slip Layer.......................................................... 81 The Sika Life Cycle Approach for Roofing Systems................. 2 1 1
́ Sika employs approx. 25’000 people worldwide Protection Layers........................................................................ 82 Sika Initiatives ........................................................................... 212
́ The Sika umbrella brand covers some 980 Sika product trademarks Protection-, Drainage and Filter Layers..................................... 83 Sustainability Performance Confirmed by EPD and LCA......... 216
́ In fiscal year 2020 the Sika Group achieved sales of approximately CHF 7.9 billion
System Overview SikaRoof® Control Systems ......................... 84 Contributing to Green Building Certification Programs........... 217

ROOFING HANDBOOK Sarnafil® T 1


Sarnafil® – THE RIGHT CHOICE

Sika Roofing has been developing and producing high-quality polymeric waterproofing membranes and system solutions for new SECURITY
construction and renovation projects for over 55 years. A flat roof provides security when it is watertight and reliably protects the building. The consequences of a leaking roof become
evident only when it is too late. The security of a flat roof is the result of an optimal combination of the right planning, material
Whether building a giant shopping mall, an international airport, an efficient factory or an ecological residential building owners, selection and installation.
architects, engineers and contractors can profit from decades of experience and know-how gained through thousands of
installations worldwide. Sarnafil® IS THE RIGHT CHOICE FOR ROOF SECURITY
́ Individual support in planning and selecting the best product system
With highly modern and environmentally responsible manufacturing processes, innovative development, and local service in over ́ Over a billion installed square metres of flat roof experience
100 countries, Sika Roofing delivers proven solutions that meet the highest standards of quality.

Sika Roofing solutions include both standard systems and individually tailored solutions that are designed to perfectly meet FIRE PROTECTION
customers, needs. For customers this means added value on the roof. Flat roofing systems that are flame sealed can easily initiate fire damage to buildings. The fire behaviour of the roofing system
after installation is also important. And a further aspect to be considered is the built-in fire load.
Sarnafil® T
For decades, building owners, architects, engineers and contractors have valued the great design freedom and variety of solu- Sarnafil® IS THE RIGHT CHOICE FOR MINIMIZING FIRE RISK
tions offered by the Sarnafil® T product line. These roofing solutions not only meet the highest requirements for appearance ́ Hot-air welded seams, no open flame during installation
and design flexibility, they perfectly suit the trends of modern architecture and ecological construction. ́ Comprehensive testing for resistance to spreading flames and radiating heat, and thus classified as "hard roofing"
́ Reduced fire load as a single-layer roof waterproofing system
The product line is supplemented by a comprehensive range of services to support customers in every stage of their projects. ́ E-versions of Sarnafil® membranes provide elevated fire protection

SUSTAINABILITY
Sustainable construction is now an established trend. More and more private builders and public owners are requesting products
and systems with proven environmental performance.

Sarnafil® IS THE RIGHT CHOICE FOR SUSTAINABLE PERFORMANCE


́ The option of sustainable construction certification through EPD / LEED
́ No hazardous materials

2 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 3


Sarnafil® – MORE THAN JUST A
ROOF WATERPROOFING MEMBRANE

REFURBISHMENT PARTNERSHIP
Damage repair is a necessity also for flat roofs. When it comes to preserving the value and substance of a building, replacement In addition to all these aspects, one concern is paramount to us: We want to be a reliable partner you can count on at all times.
of an older roof often makes more sense in practical and economical terms than attending to constant repairs year after year. From consulting to execution to support throughout the service life of your building. For optimal collaboration amongst client,
planner and applicator. With this vision in mind, we live up to our promise:
Sarnafil® IS THE RIGHT CHOICE FOR REFURBISHMENT PROJECTS
́ Qualified advice from experienced engineers and technicians
́ Comprehensive root-cause analysis of problems
́ Building-specific refurbishment concepts
́ The expertise of application technicians on site
Sarnafil® STANDS FOR RESPONSIBLE
ROOF WATERPROOFING SOLUTIONS
ADDED VALUE
Flat roofs should not be considered “wasted space”. With good building design, roof surfaces can be made useable in a cost-effec-
THAT PROVIDE LONGTERM VALUE
tive way. Treating the roof as a design element requires systems with which design concepts can be easily realized. AND PEACE OF MIND
Sarnafil® IS THE RIGHT CHOICE FOR ADDING VALUE
́ Comprehensive know-how and optimal coordination of the roofing system with any type of photovoltaic system
́ Use of the roof surface as a terrace or roof garden
́ Freedom in roof design – through colors, graphics, decor profiles, etc.

SERVICE
Today products are defined not only by material properties and test results but increasingly more by the services provided in
connection with the product systems. Ideally, service does not end with delivery but accompanies you throughout the product
lifecycle.

Sarnafil® IS THE RIGHT CHOICE WHEN IT COMES TO SERVICE


́ Individual support for all players involved in the construction project
́ Qualified technical consultants who assist in project-specific detailed planning
́ Application technicians on site
́ A strong service team in the office and in the field

4 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 5


SERVICE INFORMATION

SERVICE  INFORMATION
TECHNICAL SUPPORT ALONG Sarnafil® Sarnafil® – THE CONCEPT 8
ROOF WATERPROOFING SYSTEMS SIKA TECHNICAL ROOFING EXPERTS 9
SIKA ROOFING APPLICATION TECHNICIANS 10
BUILDING INFORMATION MODELING (BIM) OBJECTS 11
WIND LOAD CALCULATIONS 12
COMPUTER AIDED DESIGN (CAD)

PRODUCT  INFORMATION
DETAIL DRAWINGS AND PACKAGES 13
ROOF DRAINAGE 14
GUARANTEES15
PROOFEN PERFORMANCE – DURABILITY OF Sarnafil® T 16

APPLICATION  INSTRUCTIONS
STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
SERVICE INFORMATION SERVICE INFORMATION

Sarnafil® – THE CONCEPT SIKA TECHNICAL ROOFING EXPERTS

SERVICE  INFORMATION
PRODUCT  INFORMATION
APPLICATION  INSTRUCTIONS
Sarnafil® MEANS MORE THAN HIGH-QUALITY WATERPROOFING MEMBRANE SUPPORT FROM SIKA TECHNICAL
The brand is built upon a whole philosophy – the Sarnafil® concept. This concept links the tasks of the planners and applicators ROOFING EXPERTS
with our Sarnafil® polymeric waterproofing membranes, coordinated system components, and our comprehensive and compe- ́ Object-related consulting for archi-
tent technical consulting for application. This begins in the planning phase and continues through implementation with intensive tects / planners, building owners
on-site service. The Sarnafil® concept stands for optimal teamwork amongst planners, applicators and Sika – to ensure cost- and applicators
effective, long-lasting and reliable roofing. ́ Preparation of refurbishment concepts
́ Preparation of building physics calcu-
lations
SECURITY THROUGH THE SERVICES FOR PLANNERS SERVICES FOR APPLICATORS ́ Clarification of normative and con-
Sarnafil® SYSTEM ́ Project-specific consulting by highly ́ Comprehensive advice from Sika structive framework conditions
́ Service life expectancy of several qualified technicians and engineers technical roofing experts ́ Support in detailing design
decades – Sika technical roofing experts ́ Individual site supervision by Sika ́ Providing various calculation tools

STANDARD  DETAILS
́ Guarantee up to 20 years ́ Preparation of specifications / roofing application technicians ́ Preparation of fastening layouts for
́ Comprehensive range of alternative concepts ́ Complete product range from a roof areas
coordinated system accessories ́ Calculation assistance single source
́ Field-tested installation systems ́ Building physics calculations ́ Certified Sarnafil® installation
́ Sustainable roofing systems ́ Preparation of individual training
(LCA data available) refurbishment concepts
́ Over five decades of flat roof ́ Fastening plans for the roof
experience ́ Project monitoring and final
inspection
́ Support with documentation for

SUSTAINABLE  SOLUTIONS
building certifications such as EPD
and LEED
́ Installation monitoring

8 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 9


SERVICE INFORMATION SERVICE INFORMATION

SIKA ROOFING BUILDING INFORMATION


APPLICATION TECHNICIANS MODELING (BIM) OBJECTS

SERVICE  INFORMATION
BIM is a virtual design process, a construction process based on predefined products, these being full of information and in-
cludes all the different areas of execution of the work and subsequent maintenance improving collaboration between companies
throughout the supply chain.

The BIM object is a 3D geometry which acts as a real product information database, which may comprise many different topics
related to the product application and maintenance.
It includes all the necessary information that allows to perform simulations of the final aspect.

BIM files are generated based on the existing product and system data sheets. In addition to this, specific data concerning the
aspect of the materials and other thermal and physical properties may be included.
BIM equips architecture, engineering, and construction professionals with the insight and tools to more efficiently plan, design,

PRODUCT  INFORMATION
construct, and manage buildings and infrastructure.

BIM is described in many ways, but at heart it is a collaborative way of working, supported by software tools that make informa-
tion about buildings available and analyzable.

Roofing system for concrete decks based on FPO membrane with extended
guarantee
BASED ON Sarnafil® TS 77 AND Sarnafil® TS 77 E

Available membrane colours:

Sarnafil® TS 77-12 Sarnafil® TS 77-15 Sarnafil® TS 77-18 Sarnafil® TS 77-20

APPLICATION  INSTRUCTIONS
Beige

Window grey

Anthracite

Reseda green

Copper
brown
Traffic white

Traffic white, solar reflective

TRAINING COURSE OUTLINE Roofing system for concrete decks based Sarnafil® TS 77-12 E Sarnafil® TS 77-15 E Sarnafil® TS 77-18 E Sarnafil® TS 77-20 E

Our training courses teach the latest Sika Roofing technology. on FPO membrane with extended Beige

Thorough and continuing training of applicators is the best way guarantee Window grey

Anthracite

to ensure first-class workmanship. Contact your sales organ- Reseda green

isation for information about our training courses. Copper


brown
Ligh Grey

BASED ON Sarnafil® TS 77 AND Sarnafil® TS 77 E


Traffic white

Training course outline: November 28, 2019


Traffic white, solar reflective

́ Welding machines The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
Roofing system for concrete decks based on FPO membrane with extended guarantee
910_150011_1911_en

́ Welding procedures; welding seams


normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which
do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior
November 28, 2019
to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to
our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. BASED ON Sarnafil® TS 77 AND Sarnafil® TS 77 E Sika Services AG
Tüffenwies 16
NOTES: This BIM object is not valid for performance analysis. The properties and thickness corresponding to the layers with (*) in the BIM model(s), must be modified by the designer according to the specific characteristics of the project. Please, if you use a type with different colour than the one supplied on substrate (Beige), check absorptance 8048 Zürich

́ Testing welded seams


value. Contact your local Sika company to check if this product or system is available in your market.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of
Tel: +41 584364040
changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent
issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

́ Perimeter securement

STANDARD  DETAILS
Roofing system for concrete decks based on FPO membrane with extended
Detailing of: guarantee
́ Inside and outside corners BASED ON Sarnafil® TS 77 AND Sarnafil® TS 77 E

DESCRIPTION
́ Vent pipe flashings Warm roof waterproofing system for concrete decks consisting of Exposed roof system
based on FPO membrane Sarnafil® TS 77 mechanically fixed with Sarnafast® SBF 6.0 mm and
Sarnafast® Washer KTL, vapor control layer Sarnavap® 5000 E SA and Sikatherm® /

́ Skylights
Sarnatherm ® PIR insulation

USES
Waterproofing of roofs based on concrete decks with the following requirements:
▪ Fast and easy installation
Sarnafil® TS 77-12 1.25 mm or ▪ High chemical resistance of the waterproofing membrane
Sarnafil® TS 77-15 1.5 mm or
Sarnafil® TS 77-18 1.8 mm or
Sarnafil® TS 77-20 2.0 mm or
Sarnafil® TS 77-12 E 1.2 mm or
Sarnafil® TS 77-15 E
Sarnafil® TS 77-18 E
1.5 mm or
1.8 mm or
CHARACTERISTICS / ADVANTAGES
Sarnafil® TS 77-20 E 2.0 mm Sarnafil® TS 77 / Sarnafil® TS 77 E membrane:

▪ Proven performance over decades


▪ Various colours available
▪ High reflectance properties for good cool roofing characteristics
Sikatherm® PIR AL insulation* from 40 mm up to 160 mm ▪ Resistant to UV exposure
Sikatherm® PIR GT insulation* from 40 mm up to 160 mm ▪ High dimensional stability from glass fleece inlay
▪ Resistant to permanent wind exposure
▪ Resistant against impact load and hail (≥ 1.8mm)
Sarnavap®-5000 E SA 0.60 mm ▪ Resistant to most common environmental influences
▪ Resistant to micro-organisms
▪ Compatible with old bitumen

SUSTAINABLE  SOLUTIONS
▪ Hot air weldable
▪ No open flame equipment required

Concrete deck *

Based on Sarnafil® TS 77 and Sarnafil® TS 77 E

Available membrane colours: Example chart in Sheet 3

910_150011_1911_en
Roofing system for concrete decks based on FPO membrane with extended guarantee November 28, 2019
BASED ON Sarnafil® TS 77 AND Sarnafil® TS 77 E Sika Services AG
Tüffenwies 16
NOTES: This BIM object is not valid for performance analysis. The properties and thickness corresponding to the layers with (*) in the BIM model(s), must be modified by the designer according to the specific characteristics of the project. Please, if you use a type with different colour than the one supplied on substrate (Beige), check absorptance 8048 Zürich
value. Contact your local Sika company to check if this product or system is available in your market.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of
Tel: +41 584364040
changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent
issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

10 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 11


SERVICE INFORMATION SERVICE INFORMATION

WIND LOAD CALCULATIONS COMPUTER AIDED DESIGN (CAD)


DETAIL DRAWINGS AND PACKAGES

SERVICE  INFORMATION
Wind creates heavy uplift forces which can damage roofs. Wind loads at corners and perimeter can be two or three times higher Demanding specification selling requires customized and project specific detail drawings. Responsible Sika market organization is
than those in the inner area of flat roofs. When calculating uplift loads, characteristics of the building such as size, height, form, able to provide CAD detail drawings and packages for Sika Roofing.
and type of construction must be considered, as prescribed by local standards.
The roof waterproofing
Hot-air weld layer of a specific Roofing System is blue indicated40 mmall other products which can be offered by Sika
whilst
are red indicated in the detail.

Sarnafil®
On each detail S-Sealing
drawing, Membrane Tape 10/10 Roofing System, Type of Detail and Variant are mentioned. Beside that an indi-
Technology,
(if required)
vidual numbering of the detail is also provided to make every detail unique!
Sarnafil® T Metal Sheet Sarna
(Detail 2)

≥ 150 mm
Metal clip

PRODUCT  INFORMATION
40 mm
Hot-air weld
Wind Sarnafil® S-Sealing Tape 10/10
pressure (if required) Sarnacol® T-660 adhesive
Sarnafil® TS
Sarnafil® T Metal Sheet Sarnafil® TG 66 / TS 77 membrane, adhered
(Detail 2) Detail 1

≥ 150 mm
Metal clip
Hot-air weld

Sarnabar®
Sarnacol® T-660 adhesive with Sarnafast® Fasteners and
Sarnafil® TS 77 membrane, mechanically fastened
Wind suction zone Sarnafil® T Welding Cord
Detail 1
Metal flashing S-Glass Fleece-120 separation layer,
Sarnabar® with Sarnafast® Fasteners and fire protection layer (if required)
Sarnafil® T Welding Cord

APPLICATION  INSTRUCTIONS
Metal flashing
Sarnavap® adhesive tape Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer

900_020910_910010102C_1901_en
Sarnavap® adhesive tape
(positioning according to local
climate conditions and regulations)

900_020910_910010102C_1901_en
Detail 2
Recirculation zone Detail 1 Detail 2 Sarnafil® T Metal Sheet Fastening
Detail 1 Sarnafil® T Metal Sheet Fastening
Sarnabar® Perimeter
Sarnabar® Perimeter
Securement
Securement Vertical Vertical (Alternative)
(Alternative) m m
10
0m 0m
m 10
0m m
10
0m
10
0 mm 10
Sika offers a commercial, web-based software – RoofCalculator™ which is a versatile tool, used by the local Sika sales organiza- m
0m
m
0m
tions to calculate mechanical fastened, adhered or ballasted roofing systems. 10 10
m
The basis for performing roofing calculations is the normative standard EN 1991-1-4 – wind actions on building structures including 0m
10
country specific national annexes and Factory Mutual meeting FM datasheet 1-28 requirements.
The customer receives a roof plan for optimized and efficient installation of the membranes and fasteners. The attached bill of
quantities defines the numbers and types of fasteners to be used and the required quantity of membrane for the specific project. SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010102C_1901_en Sika Services AG

STANDARD  DETAILS
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.01.02 - Parapet - Sarnafil® T Metal Sheet - Adhered on Metal Parapet Element 8048 Zürich
Sika General Detail. Template for translation.
Switzerland

THE MAIN FACTORS THAT INFLUENCE WIND LOADS ARE SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Tel: +41 584364040 900_020910_910010102C_1901_en Sika Services AG
January 2019
The building location (topography and surrounding environment) ON METAL DECK WITH THERMAL INSULATION
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
Tüffenwies 16
SF TPO - 001.01.02 - Parapet - Sarnafil® T Metal Sheet - Adhered on Metal Parapet Element 8048 Zürich
́ Building height Sika General Detail. Template for translation.
́ Building shape and geometry Switzerland
́ Air permeability of the building shell (internal building pressure) The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 5843640
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
́ Openings in the building (number and size) Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
́ Design of the roof area (substructures and penetrations)

SUSTAINABLE  SOLUTIONS
12 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 13
SERVICE INFORMATION SERVICE INFORMATION

ROOF DRAINAGE GUARANTEES

SERVICE  INFORMATION
DRAINAGE OF FLAT ROOFS Performance over time is the ultimate demonstration of the quality of a roofing system. We have been successfully developing,
The drainage of flat roofs is essential to drain off rain water and to protect the roof against moisture damage and warping. Sika producing and installing Sika Roofing Systems for over 50 years. An investment in a Sika Roofing System is an investment in a
products are available for flat roofs of solid or lightweight construction. These days, the most common roof structure is the proven technology and performance – proven by thousands of watertight roofs around the world.
single-ply, non-ventilated flat roof (warm roof). This can also be converted to an inverted roof. Unlike a conventional non-ventilated
flat roof, in a inverted roof construction the waterproofing is located beneath the thermal insulation. Technical details of the GUARANTEE TYPE
drainage solutions will always need to be tailored to the particular features of the building. Generally speaking, when dealing with Sika roofing membranes are produced using controlled high-quality raw materials. The membranes are subject to many stages
flat roofs, a distinction is made between non-utilised surfaces, i.e foot traffic only occurs for the purpose of maintenance, and and forms of quality control during and after manufacturing. Sika thus offers a guarantee for Sarnafil® product line. This guaran-
utilised flat roofs, which can withstand the weight and impact of pedestrian and/or vehicle traffic. tee covers:
́ Watertightness of Sarnafil® membrane and its accessories
DESIGN CONSIDERATION ́ Products delivered by Sika are compatible with these membranes and fulfill their respective functions within the roof build-up
In the case of flat roofs, drainage is carried out at roof low points; each low point of a roof surface is drained via a roof drain and

PRODUCT  INFORMATION
an overflow drain. Drainpipes must be thermally insulated if the rooms below are heated as they represent thermal bridges in the Guarantee will be issued individually for each project by the local Sika Organization, in conformance with local laws. The guarantee
roof structure. Heated drains prevent icing in freezing temperatures, particularly if the rooms below are not heated. can be issued as requested either to the applicator or the owner.

Roof drains must be positioned so that their flange outer edge is at least 30 cm away from the outer edges of other installations
on the roof, joints or other ducts penetrating the roof membrane. Roof drains are delivered with connecting flanges that are
welded to the roof waterproofing membranes.

APPLICATION  INSTRUCTIONS
33%
ZKK&/E'^z^dD'hZEd
ϭϱzZ^
100%
WW>/dKZʹ΀EĂŵĞŽĨŽŵƉĂŶLJ΁


Gravity drainage system with partially (33%) filled rain water pipes. Siphonic drainage system with fully (100%) filled rain water pipes.

GRAVITY DRAINAGE
With gravity drainage, the water is drained over several downpipes into a drainage pipe laid in the slope where it is drained away
from the roof. Drainage of the rainwater occurs according to the physical law of gravity. The drainage rate is primarily influenced

STANDARD  DETAILS
by the slope of the outlet pipe and the structure of the roof drain. The pipe system for gravity drainage should always be partially
filled with water.

SIPHONIC DRAINAGE
In the case of siphonic drainage, the outlet flows of the individual drains are transported to a common downpipe via connecting
pipes underneath the roof structure. Drainage of the rainwater creates a negative pressure in the collecting main, which ensures
the quick and effective drainage of the roof area at a high flow rate. Because the pressure pipe system is operated fully-filled acc.
to the physical law of negative pressure, the pipes running underneath the roof can be laid without a slope, enabling spaces to be
used more effectively.

SUSTAINABLE  SOLUTIONS
OVERFLOW DRAINAGE
The controlled functionality of the rain drainage system, both in the partial load range and in the event of an overload, e.g. in the
case of once-in-a-century rainfall levels, must be ensured at all times. For such events, the standard stipulates the need for an
overflow drainage system in the form of an overflow drain. Furthermore, the overflow drainage system must be connected to a
dedicated outflow from which the water can drain freely onto floodable land - it must not be connected to the normal drainage
system.

14 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 15


SERVICE INFORMATION

PROOFEN PERFORMANCE –
DURABILITY OF Sarnafil® T

SERVICE  INFORMATION
Sarnafil® T membranes have been in use now for 30 years. During this period of time,
several investigation and expert reports were published.

The latest investigation and expert report dated from December 2014 which concerns
the durability of polymeric roofing membrane types Sarnafil® TS 77 and Sarnafil® TG
66 (based on a study of five 17 to 25 years old roofs, plus 158 additional roofs that
were investigated and assessed by Sika personnel in a field survey, and also including
Sika’s internal production monitoring data and test results).

The roof assessment and testing has been conducted independently of the Sika
surveys and testing, according to following criteria:

PRODUCT  INFORMATION
́ Roof assessment: General condition of the roof, roof build-up / assembly, flash-
ings, welded seams, structural aspects.
́ Material samples: Thickness, tensile strength, elongation at break, low tempera-
ture foldability, peel strength and shear strength of site-welded seams, including
the seams of new membranes welded onto existing exposed membranes, together
with microscopic investigation of the membrane surface. These properties are
those regarded as essential for predicting the durability of polymeric waterproofing
membranes.

The results of this long term study and the 25 years of proven, positive experience for the durability of Sarnafil® T suggests

APPLICATION  INSTRUCTIONS
that given ensuring the standard roof conditions and use in compliance with the products application and maintenance
requirements, the polymeric roofing membranes Sarnafil® T will continue to fulfil their waterproofing function for many
more years.

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
Olympic Swimming Pool, Deauville, France – Sarnafil® T, white, 1997

16 ROOFING HANDBOOK Sarnafil® T


AND CORRESPONDING SYSTEM ACCESSORIES
Sarnafil® T ROOF WATERPROOFING MEMBRANES
PRODUCT INFORMATION

SUSTAINABLE  SOLUTIONS STANDARD  DETAILS APPLICATION  INSTRUCTIONS PRODUCT  INFORMATION SERVICE  INFORMATION
PRODUCT INFORMATION

PRODUCT OVERVIEW

SERVICE  INFORMATION
Sarnafil® T ROOF WATERPROOFING MEMBRANES – Primer-780. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 – Sarnafast® Insulation Washer DTL. . . . . . . . . . . . . . . . . . . . . . 69 Technology Overview Thermal Insulations . . . . . . . . . . . . . . . 90
– Primer T-501. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 – Sarnafast® Insulation Washer DT. . . . . . . . . . . . . . . . . . . . . . . 69
Material and Manufacturing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 – S-Sealing Tape 10/10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 – Sarnabar® Fastening Profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Thermal Insulations
– Sikaflex®-11 FC+. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 – Sarnabar® Tube SBT-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 – Sikatherm® PIR GT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Inlays, Fleece- and Self Adhesive Film Backings. . . . . . . . . . . 23 – Sarnaplast®-2235 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 – Sarnabar® Connection Clip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 – Sikatherm® PIR AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
– SikaBond® TF plus N. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 – Sarnafil® T Welding Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 – Sikatherm® EPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Roof Design – Released / Approved Applications for Sealants. . . . . . . . . . . 51 – Sarnafast® Fastener SBF-6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 – Sikatherm® XPS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
– Decor Profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 – Sarnafast® Fastener SF-4.8. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1
– Sikagard® Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Prefabricated Products – Sarnafast® Fastener SF-M 4.8 . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 Product Overview Vapour- Control Layers / Barriers . . . . . . 100
– Sarnafil® Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 – Sarnafil® T Preformed Components CI / WA. . . . . . . . . . . . . . 52
– Sarnafil® T Corner 90° I / A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Fastening Products – Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Vapour Control Layers

PRODUCT  INFORMATION
Color Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 – Sarnafil® T Pipe Flashing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 – Sarnavap®-1000 E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  101
– Sarnafil® T Post Flashing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Roof Design – Sarnavap®-2000 E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  101
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 – Sarnafil® T Lightning Conductor Flashing. . . . . . . . . . . . . . . . 53 – Sarnafil® T Decor Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 – Sarnavap®-3000 M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  101
– Sarnafil® T Lightning Conductor Circus . . . . . . . . . . . . . . . . . . 54 – Sikagard®-950. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
External Fire Performance – S-Lightning Conductor Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 – Sikalastic® Primer FPO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Vapour Barriers
– Mechanically Fastened Roofs . . . . . . . . . . . . . . . . . . . . . . . . . . 28 – S-Lightning Conductor Clip V2A . . . . . . . . . . . . . . . . . . . . . . . . 54 – S-Vap®-4000 E SA FR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
– Adhered Roofs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Product Overview Felts and Glass Fleece . . . . . . . . . . . . . . . . . 76 – Sarnavap®-5000 E SA FR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Roof Drainage – Sarnavap®-5000 E SA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Chemical Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 – Sarnafil® T Gully Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Levelling- and Protection Layers
– Sarnafil® Gully Horizontal / Vertically. . . . . . . . . . . . . . . . . . . . 55 – S-Felt A-300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Vapour- Control Layers / Barriers Accessories
Product Properties – Sarnafil® T Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 – Sikaplan W Felt 500 PP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 – Sarnavap® Tape F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

APPLICATION  INSTRUCTIONS
– Sarnafil® TG 66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 – S-Gully Overflow screw-on device. . . . . . . . . . . . . . . . . . . . . . . 56 – S-Felt S-800. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 – Sarnatape®-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
– Sarnafil® TG 76 Felt PS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 – Sarnafil® T Overflow – round. . . . . . . . . . . . . . . . . . . . . . . . . . . 56 – Sarnatape®-60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
– Sarnafil® TG 76 Felt PS E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 – Sarnafil® T Overflow – square. . . . . . . . . . . . . . . . . . . . . . . . . . 57 Separation-, Levelling- and Protection Layer – Primer-130 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
– Sarnafil® TG 76 FSA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 – Sarnafil® T Scupper – round. . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 – S-Felt T-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 – Primer-600. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
– Sarnafil® TS 77. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 – SikaRoof® Drain Inspection chamber. . . . . . . . . . . . . . . . . . . . 57
– Sarnafil® TS 77 E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 – S-Leafguard round. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Separation- and Fire Protection Layer System Overview Fall Arrest Systems. . . . . . . . . . . . . . . . . . . 106
– S-Gravel Frame stainless steel . . . . . . . . . . . . . . . . . . . . . . . . 58 – S-Glass Fleece-120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Sarnafil® T ACCESSORIES – S-Grid stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Fall Arrest Systems
– Gravel Frame with adjustable put on frame . . . . . . . . . . . . . . 59 Filter Layer – ABS Point. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Detailing Membrane – Perforated strainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 – S-Felt VS-140. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 – Sarnafil® T Point Flashing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
– Sarnafil® T 66-15 D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 – S-Duoseal Couplings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 – Sarnafil® T Seculine Vario Flashing. . . . . . . . . . . . . . . . . . . . . 108
Protection- and Slip Layer – Seculine® Vario Anchor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Metal Sheet / Coil Ancillary Components – S-Felt GK-400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 – Seculine® Vario Seal Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
– Sarnafil® T Metal Sheet / Coil. . . . . . . . . . . . . . . . . . . . . . . . . . 41 – SikaRoof® Cable Duct-110. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 – Seculine® Vario Ancillary Products . . . . . . . . . . . . . . . . . . . . . 110
– S-Gravelstop Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Protection Layers
Welding Preparation / Cleaners – Sarnafil® T Gravelstop bracket. . . . . . . . . . . . . . . . . . . . . . . . . 60 – Sarnafil® TG 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Application Tools

STANDARD  DETAILS
– Sarnafil® T Prep. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 – Paving support Pad / levelling shim. . . . . . . . . . . . . . . . . . . . . 61 – Sarnafil® TG 37-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 – Sarnamatic-681. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  111
– Sarnafil® Wet Task-Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 – Snow guard holder galvanized. . . . . . . . . . . . . . . . . . . . . . . . . . 61 – S-Protection Sheet RS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 – Sika Membrane slitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  111
– Sarnafil® Seam Preparation Cloths. . . . . . . . . . . . . . . . . . . . . . 43 – Snow guard stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 – Sarnafil® Gas Heat Gun. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  112
– Sarnafil® T Clean. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Protection-, Drainage- and Filter Layers – Spray Application Gun. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  112
– Solvent T-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Walkways – Aquadrain 550. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 – Fitting Tool for Sarnabar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  112
– Sarnafil® T Walkway Pad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 – SikaRoof® Drainage Layer 20L2F . . . . . . . . . . . . . . . . . . . . . . 83 – Leister Triac AT / ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  112
Solvent Free Cleaners – Sarnafil® T TuffLane 40 YB . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 – Spare Parts for Leister Hand Welding Tool . . . . . . . . . . . . . .  113
– SikaRoof® Clean Set Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 – Sarnafil® TG-20 WW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 System Overview SikaRoof® Control Systems. . . . . . . . . . . . 84
– SikaRoof® Clean Pad Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . 44
– SikaRoof® Clean Agent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Connection System SikaRoof® Control Systems

SUSTAINABLE  SOLUTIONS
– SikaRoof® Clean Set Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 – Sarnafil® T Dilatec® ER-300. . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 – Sarnafil® T Control Pipe Set. . . . . . . . . . . . . . . . . . . . . . . . . . . 89
– SikaRoof® Clean Pad Area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 – Sikadur Combiflex® CF Adhesive Normal / Rapid. . . . . . . . . . 65 – Sika® RCS Glass Fleece. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
– Sika® RCS Stainless Steel Mesh . . . . . . . . . . . . . . . . . . . . . . . 89
Adhesives, Primers and Sealants Fastening Products – SikaRoof® Control Contact Plate. . . . . . . . . . . . . . . . . . . . . . . 89
– Sarnacol® T-660. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 – Sarnafast® Washer KTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
– Sarnacol®-2142 S / -2142 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 – Sarnafast® Washer KT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
– Sarnacol®-2116. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 – Sarnafast® Washer IF/IG-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
– SikaRoof® Tape P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 – Sarnafast® Tube SFT-50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
– SikaRoof® Board Adhesive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 – Sarnafast® Row Termination Plate RTL. . . . . . . . . . . . . . . . . 68
– Sika® Primer-3 N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 – Sarnafast® Row Termination Plate RT. . . . . . . . . . . . . . . . . . 68

20 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 21


Sarnafil® T ROOF WATERPROOFING MEMBRANES Sarnafil® T ROOF WATERPROOFING MEMBRANES

MATERIAL AND MANUFACTURING INLAYS, FLEECE- AND SELF


ADHESIVE FILM BACKINGS

SERVICE  INFORMATION
PRODUCTION PROCESS 900_020910_N0006O_1908_en Sarnafil® TG 66
Sarnafil® T is a polymeric allow made of a blend of premium-quality flexible poly- Sarnafil® TG 66 has a fully embedded inlay of glass non-woven /
olefins. Sarnafil® T membrane is manufactured in a patented process in which the glass scrim fabric. Because of the dimensionally stable inlay
reinforcement or support layer is extrusion-coated to produce a membrane without and the special manufacturing process, Sarnafil® TG 66 mem-
internal tension. brane undergoes no deformation during manufacturing. That’s
why Sarnafil® TG 66 is dimensionally stable on the roof, even in
Sarnafil® T membrane is carefully produced on specially designed machines. In the heat.
extruders, the synthetic components and additives are melted, mixed and then uni-
formly coated onto both sides of the reinforcement mesh or support layer.

PRODUCT  INFORMATION
900_020910_N0007O_1908_en
Sarnafil® TG 76 Felt PS / TG 76 Felt PS E
Sarnafil® TG 76 Felt PS / TG 76 Felt PS E uses the same prod-
Components
uct design and manufacturing process as Sarnafil® TG 66. The
polyester and glass mix fleece backing provides an integrated
separation layer and keying for full surface adhesion.
Cooling Winding

Extruder

APPLICATION  INSTRUCTIONS
Support layer or reinforcing

900_020910_N0005O_2009_en
Sarnafil® TG 76 FSA
Sarnafil® TG 76 FSA uses the same product design and manu-
Extruder
facturing process as Sarnafil® TG 66. The polyester and glass
mix fleece backing provides an integrated separation layer
together with a factory- applied self-adhesive film for surface
adhesion.

Components

STANDARD  DETAILS
900_020910_N0008O_1908_en Sarnafil® TS 77 / TS 77 E
QUALITY MANAGEMENT Sarnafil® TS 77 / TS 77 E has an embedded inlay of glass
Sika roof waterproofing membranes are under permanent quality monitoring during non-woven / glass scrim fabric plus a polyester reinforcement
manufacturing process. The monitoring also includes the controlling of incoming ad- mesh. This gives Sarnafil® TS 77 / TS 77 E higher resistance
mixtures and materials during all stages of production up to the testing of produced to tearing and the relatively low elongation at break required
membranes until shipped to the project site, complete recorded by ISO-9001 quality formechanical fastening. Sarnafil® TS 77 / TS 77 E is produced
management, ISO 14001 environmental management and OHSAS 18001 occupational the same way as Sarnafil® TG 66 and therefore is dimension-
health and safety management system certification. ally stable on the roof, even in the heat.
Beside the internal testing of our Sika roof waterproofing membranes, external qual-

SUSTAINABLE  SOLUTIONS
ity control is provided by independent and governmental material test institutes.

Based on this reasons and our experience for decades, Sika provides waterproofing
systems on highest technical level.

T Product family / group / type 12 / 15 / 18 / 20 /25 Membrane thickness (in tenths of mm)
G Glass non-woven inlay Felt PS Fleece backing made of polyester
S Polyester reinforcement E Enhanced fire rating
76 / 77 Material reference number FSA Felt with a self-adhesive film

22 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 23


Sarnafil® T ROOF WATERPROOFING MEMBRANES Sarnafil® T ROOF WATERPROOFING MEMBRANES

ROOF DESIGN COLOR CHART

SERVICE  INFORMATION
DECOR PROFILES BASIC COLORS STANDARD COLORS OTHER COLORS
Sarnafil® decor profiles can imitate the
appearance of a sheet metal roof with a
Beige Reseda green
standing seam covering. The decorative
profiles are particularly suitable for the
renovation of old buildings where the RAL 6011
original appearance is to be retained.
In addition, architecturally attractive
aspects can be set in relation to the roof Light grey Antracite
design.

PRODUCT  INFORMATION
RAL 7035 RAL 7016

Window grey Copper brown


On request
RAL 7040 RAL 8004

Traffic white

Sikagard® GRAPHICS
Sikagard®-950 is particularly suitable RAL 9016

APPLICATION  INSTRUCTIONS
for graphic surface design of Sarnafil®
waterproofing membranes. For example, Traffic white
it can be used to color mark rescue and
maintenance routes, to mark hospitals
or to apply (company) logos, for example RAL 9016 SR
near airports or for satellite images on
the Internet.
SR = Solar Reflective

Colors are similar to the given RAL colors (not identical). Attention, printing is not binding!

Availability for special and customized colors – contact your Sika sales organization.

STANDARD  DETAILS
Sarnafil® COLORS
Sarnafil® waterproofing membranes are
available in various colors. This allows
the roof waterproofing to harmonise
perfectly with the color of the building
and its surroundings. For example, it
matches red tiled roofs, green land-
scapes or blue skies.

SUSTAINABLE  SOLUTIONS
Depending on the climate, the color of
the roof waterproofing can also make
a big difference to the interior climate
of the building. In warm regions, for
example, a white track with high solar
reflection values is recommended.

24 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 25


Sarnafil® T ROOF WATERPROOFING MEMBRANES

PRODUCT OVERVIEW

SERVICE  INFORMATION
ROOF SYSTEMS SUSTAINABILITY PRODUCT CERTIFICATION
Membrane type Thickness Mechanically
Adhered Green Gravel ballasted Utility Inverted Upstands EPD LEED FM FLL BBA
fastened

Sarnafil® TG 66-12 1.20 mm

Sarnafil® TG 66-15 1.50 mm

Sarnafil® TG 66-18 1.80 mm

Sarnafil® TG 66-20 2.00 mm

PRODUCT  INFORMATION
Sarnafil® TG 76-15 Felt PS 1.50 mm

Sarnafil® TG 76-18 Felt PS 1.80 mm

Sarnafil® TG 76-20 Felt PS 2.00 mm

Sarnafil® TG 76-15 Felt PS E 1.50 mm

Sarnafil® TG 76-18 Felt PS E 1.80 mm

Sarnafil® TG 76-20 Felt PS E 2.00 mm

Sarnafil® TG 76-15 FSA 1.50 mm

APPLICATION  INSTRUCTIONS
Sarnafil® TG 76-18 FSA 1.80 mm

Sarnafil® TG 76-20 FSA 2.00 mm

Sarnafil® TS 77-12 1.20 mm

Sarnafil® TS 77-15 1.50 mm

Sarnafil® TS 77-18 1.80 mm

Sarnafil® TS 77-20 2.00 mm

Sarnafil® TS 77-25 2.50 mm

Sarnafil® TS 77-12 E 1.20 mm

Sarnafil® TS 77-15 E 1.50 mm

Sarnafil® TS 77-18 E 1.80 mm

STANDARD  DETAILS
Sarnafil® TS 77-20 E 2.00 mm

Sarnafil® TG 63 / 37 various Protection layer for ballasted roofs (not UV-resistant)

Sarnafil® TG 66-15 D 1.50 mm Homogeneous membrane for detailing

Standard Products according to CE Marking EN 13956


Suitable

FM Factory Mutual – approval standard 4470


FLL Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau e.v. – resistance to root penetration, according to EN 13948

SUSTAINABLE  SOLUTIONS
BBA British Board of Agrément – approval inspection, testing certification
EPD Environmental Product Declaration – as per ISO 14025 and 15804
LEED Leadership in Energy & Environmental Design – green building rating system

26 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 27


Sarnafil® T ROOF WATERPROOFING MEMBRANES

EXTERNAL FIRE PERFORMANCE


MECHANICALLY FASTENED ROOFS

SERVICE  INFORMATION
BROOF T1 BROOF T2 BROOF T3 BROOF T4
Thermal insulation Glass fleece Membrane thickness
Sarnafil® TS 77 Sarnafil® TS 77 E Sarnafil® TS 77 Sarnafil® TS 77 E Sarnafil® TS 77 Sarnafil® TS 77 E Sarnafil® TS 77 Sarnafil® TS 77 E

yes 1.20 mm < 20° < 20°, > 20°

yes 1.50 mm < 20° < 20°, > 20°

EPS yes 1.80 mm < 20° < 20°, > 20° pass

yes 2.00 mm < 20° < 20°, > 20° pass

yes 2.50 mm < 20° pass

PRODUCT  INFORMATION
no 1.20 mm < 20° < 20°, > 20° pass pass

no 1.50 mm < 20° < 20°, > 20° < 10°, < 70° pass pass

PIR no 1.80 mm < 20° < 20°, > 20° < 10°, < 70° pass pass

no 2.00 mm < 20° < 20°, > 20° < 10°, < 70° pass pass

no 2.50 mm < 20° pass

no 1.20 mm < 20° < 10°, < 70° pass pass

no 1.50 mm < 20° < 10°, < 70° pass pass

APPLICATION  INSTRUCTIONS
Mineralwool no 1.80 mm < 20° < 10°, < 70° pass pass

no 2.00 mm < 20° < 10°, < 70° pass pass

no 2.50 mm < 20°

no 1.20 mm < 20°

no 1.50 mm < 20° < 10°, < 70°

Wood no 1.80 mm < 20° < 10°, < 70°

no 2.00 mm < 20° < 10°, < 70°

no 2.50 mm < 20°

no 1.20 mm < 20°

no 1.50 mm < 20°

STANDARD  DETAILS
Bitumen no 1.80 mm < 20°

no 2.00 mm < 20°

no 2.50 mm < 20°

no 1.20 mm < 20°

no 1.50 mm < 20°

Concrete no 1.80 mm < 20°

SUSTAINABLE  SOLUTIONS
no 2.00 mm < 20°

no 2.50 mm < 20°

Glass fleece min. 120 g/m²

28 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 29


Sarnafil® T ROOF WATERPROOFING MEMBRANES

EXTERNAL FIRE PERFORMANCE


ADHERED ROOFS

SERVICE  INFORMATION
BROOF T1 BROOF T2 BROOF T3 BROOF T4
Membrane Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil® Sarnafil®
Thermal insulation
thickness TG 76 Felt PS TG 76 Felt PS E TG 76 FSA TG 76 Felt PS TG 76 Felt PS E TG 76 FSA TG 76 Felt PS TG 76 Felt PS E TG 76 FSA TG 76 Felt PS TG 76 Felt PS E TG 76 FSA
Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142 Sarnacol®-2142

1.50 mm < 20° < 20°, > 20° < 20°

EPS 1.80 mm < 20° < 20°, > 20° < 20°

2.00 mm < 20° < 20°, > 20° < 20°

PRODUCT  INFORMATION
1.50 mm < 20° < 20°, > 20° < 20° pass pass

PIR 1.80 mm < 20° < 20°, > 20° < 20° pass pass

2.00 mm < 20° < 20°, > 20° < 20° pass pass

1.50 mm < 20° < 20°, > 20° < 20° pass

Mineralwool 1.80 mm < 20° < 20°, > 20° < 20° pass

2.00 mm < 20° < 20°, > 20° < 20° pass

1.50 mm < 20° < 20°, > 20° < 20°, > 20° pass pass

APPLICATION  INSTRUCTIONS
Wood 1.80 mm < 20° < 20°, > 20° < 20°, > 20° pass pass

2.00 mm < 20° < 20°, > 20° < 20°, > 20° pass pass

1.50 mm < 20° < 20°, > 20° < 20°, > 20°

Bitumen 1.80 mm < 20° < 20°, > 20° < 20°, > 20°

2.00 mm < 20° < 20°, > 20° < 20°, > 20°

1.50 mm < 20° < 20°, > 20° < 20°, > 20° pass

Concrete 1.80 mm < 20° < 20°, > 20° < 20°, > 20° pass

2.00 mm < 20° < 20°, > 20° < 20°, > 20° pass

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
30 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 31
Sarnafil® T ROOF WATERPROOFING MEMBRANES

CHEMICAL RESISTANCE

SERVICE  INFORMATION
The chemical resistance of Sarnafil® T roof waterproofing membranes generally depends on concentration, temperature and
duration of exposure.
The table below shows the resistance of Sarnafil® T roof waterproofing membranes to a range of substances at an ambient
temperature of +20 °C. If exposed to certain substances mentioned below, discoloration or other surface changes may occur, but
these have no influence on the waterproofing function (even in the long term). For example bitumen, lactic acid, bird droppings etc.

Contact your sales organisation for information on resistance to other substances and types of exposure you expect in your
specific project.

PRODUCT  INFORMATION
Type Assessment Type Assessment

Asphalt Plasticizers

Bird droppings Polystyrene

Bitumen Polyurethan

Carbon black Potash lye 5%

Common salt Red algae

Detergends Salt (without splitt)

APPLICATION  INSTRUCTIONS
Diesel oil Salt of
– Aluminium
Fats Animal / Vegetable
– Ammonium
Ferrous residue – Calcium
– Kalium
Fuel oil
– Potassium
Fungizide – Sodium

Gasoline Sea water

Glycol Silicone oil

Hydrochloric acid 5% Soft soap

Insecticides Sulphuric acid 5%

Kerosene Tar

STANDARD  DETAILS
Lactic acid Turbentine oil

Lake water Urea

Mineral oils (non-aromatic) Water glass

Motor oil Wax

Natron lye 5% Weed killer

Oils Weed killer (aqueous)


Animal / Vegetable
Wood preservative

SUSTAINABLE  SOLUTIONS
Paraffin – Water-based
 1)
– Solvent-based  
Paraffin oil

Petroleum

Resistant
Conditionally resistant
Non resistant
1)
Paint needs to dry for at least 24 hours

32 ROOFING HANDBOOK Sarnafil® T


Sarnafil® T ROOF WATERPROOFING MEMBRANES

PRODUCT PROPERTIES

SERVICE  INFORMATION
Sarnafil® TG 66 DESCRIPTION APPEARANCE / COLOR Sarnafil® TG 76 Felt PS DESCRIPTION APPEARANCE / COLOR
Sarnafil® TG 66 is a multi-layer, syn- Surface: Sarnafil® TG 76 Felt PS is a multi-layer, Surface:
thetic roof waterproofing sheet based ́ Matt synthetic roof waterproofing sheet ́ Matt
on premium-quality flexible polyolefins Top surface: based on premium-quality flexible poly- Top surface:
(FPO), with inlay of glass non-woven ́ Beige olefins (FPO), containing stabilizers, with ́ Beige
according to EN 13956. ́ Window grey (RAL 7040) inlay of glass non-woven and polyester / ́ Window grey (RAL 7040)
Sarnafil® TG 66 is a hot air weldable, UV- Bottom surface: glass mix fleece backing according to ́ Traffic white (RAL 9016)
resistant roof membrane, designed for • Black EN 13956. Bottom surface:
use in all global climatic conditions. Sarnafil® TG 76 Felt PS is a hot air ́ Black
Please check color policy weldable, UV-resistant roof membrane,
USES designed to use in all global climatic Please check color policy

PRODUCT  INFORMATION
Roof waterproofing membrane for: SYSTEM STRUCTURE conditions.
́ Loosely laid and ballasted roofs The following products must be consid- SYSTEM STRUCTURE
́ Green roofs ered for use depending on roof design: USES The following products must be consid-
́ Utility roofs ́ Sarnafil® T 66-15 D Sheet for detailing Roof waterproofing membrane for: ered for use depending on roof design:
́ Inverted roofs ́ Sarnafil® T Metal Sheet ́ Adhered roofs ́ Sarnafil® T 66-15 D Sheet for detailing
́ Sarnafil® T Welding Cord ́ Sarnafil® T Metal Sheet
Roof waterproofing membrane for ex- ́ Sarnabar® Approved substrates: ́ Sarnacol®-2142
posed roof junction zones: ́ Sarnafil® T Prep / Sarnafil® T Wet Task ́ Slated/mineralized bitumen sheets; ́ Sarnabar®
́ Roof waterproofing for junctions Set new and aged ́ Sarnafil® T Prep / Sarnafil® T Wet Task
and flashings, e.g. wall and parapet ́ Sarnacol® T 660 ́ EPS: compressive strength ≥ 100 kPa Set
junctions, roof lights, etc., which are ́ Solvent T 660 (10%), Density >20 kg/m³ ́ Sarnacol® T 660

APPLICATION  INSTRUCTIONS
permanently exposed in installations ́ Sarnafil® T Clean ́ OSB, plywood, fibre cement boards ́ Solvent T 660
of Sarnafil® TG 66 roof waterproofing ́ Mineral fibre boards (e.g. Bondrock ́ Sarnafil® T Clean
systems with ballast Wide range of accessories is available MV)
́ Roof waterproofing for junctions and e.g. prefabricated parts, roof drains, ́ PUR/PIR insulation boards, (e.g. Sar- Wide range of accessories is available
flashings in installations of all types of scuppers, walkway pads and decor natherm PIR GT, Kingspan TR 27) e.g. prefabricated parts, roof drains,
Sarnafil® TS 77 and TG 76 Felt exposed profiles. ́ Concrete, lightweight concrete scuppers, walkway pads and decor
roof waterproofing systems profiles.
CHARACTERISCTICS / ADVANTAGES
CHARACTERISCTICS / ADVANTAGES ́ Proven performance over decades
́ Proven performance over decades ́ Resistant to micro-organism
́ Resistant to micro-organism ́ Various colors available
́ Resistant to root penetration ́ High dimensional stability due to glass
́ High dimensional stability due to glass fleece inlay
fleece inlay ́ Resistant to permanent UV exposure
́ Resistant to permanent UV exposure ́ Compatible to bitumen
́ Compatible to bitumen ́ Hot air weldable without use of open

STANDARD  DETAILS
́ Resistant against impact load and hail flames
́ Resistant to all common environmen- ́ Recycable
tal influences
́ Resistant to mechanical influences
́ Hot air weldable
́ Recycable

SUSTAINABLE  SOLUTIONS
34 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 35
Sarnafil® T ROOF WATERPROOFING MEMBRANES

PRODUCT PROPERTIES

SERVICE  INFORMATION
Sarnafil® TG 76 Felt PS E DESCRIPTION APPEARANCE / COLOR Sarnafil® TG 76 FSA DESCRIPTION APPEARANCE / COLOR
Sarnafil® TG 76 Felt PS E a multi-layer, Surface: Sarnafil® TG 76 FSA is a multi -layer syn- Surface:
synthetic roof waterproofing sheet ́ Matt thetic roof waterproofing sheet based ́ Matt
based on premium-quality flexible poly- Top surface: on premium-quality flexible polyolefins Top surface:
olefins (FPO), containing stabilizers, with ́ Beige (FPO), containing stabilizers, with inlay ́ Beige
inlay of glass non-woven and polyester / ́ Window grey (RAL 7040) of glass non-woven/glass scrim and ́ Window grey (RAL 7040)
glass mix fleece backing according to EN ́ Traffic white (RAL 9016) polyester fleece backing and factory ́ Traffic white (RAL 9016)
13956. Bottom surface: applied self-adhesive film according to Bottom surface:
Sarnafil® TG 76 Felt PS E is a hot air ́ Black EN 13956. ́ Black
weldable, UV-resistant roof membrane, Sarnafil® TG 76 FSA is produced with an
designed to use in all global climatic Please check color policy inlay of glass non-woven for dimensional Please check color policy

PRODUCT  INFORMATION
conditions. Sarnafil® TG 76 Felt PS E is stability.
produced with an inlay of glass non- SYSTEM STRUCTURE SYSTEM STRUCTURE
woven for dimensional stability. The following products must be consid- USES The following products must be consid-
ered for use depending on roof design: Roof waterproofing membrane for: ered for use depending on roof design:
USES ́ Sarnafil® T 66-15 D Sheet for detailing ́ Adhered roofs ́ Sarnafil® T 66-15 D Sheet for detailing
Roof waterproofing membrane for: ́ Sarnafil® T Metal Sheet ́ Sarnafil® T Metal Sheet
́ Adhered roofs ́ Sarnacol®-2142 CHARACTERISCTICS / ADVANTAGES ́ Sarnafil® T Welding Cord
́ Sarnabar® ́ Fast installation of membrane ́ Sarnabar®
CHARACTERISCTICS / ADVANTAGES ́ Sarnafil® T Prep / Sarnafil® T Wet Task ́ Instant wind uplift resistance through ́ Sarnafil® T Prep / Sarnafil® T Wet Task
́ Outstanding resistance to weathering, Set the self-adhesive backing Set
including permanent UV exposure ́ Sarnacol® T 660 ́ Proven performance over decades ́ Sarnacol® T 660

APPLICATION  INSTRUCTIONS
́ Excellent flexibility in cold tempera- ́ Solvent T 660 ́ High dimensional stability due to glass ́ Solvent T 660
tures ́ Sarnafil® T Clean fleece inlay ́ Sarnafil® T Clean
́ No built-in stress at the time of ́ Resistant to permanent UV exposure ́ Primer 780
production Wide range of accessories is available ́ Resistant to micro-organism
́ High dimensional stability e.g. prefabricated parts, roof drains, ́ Resistant against impact load and hail Wide range of accessories is available
́ High resistance against impact load scuppers, walkway pads and decor ́ Hot air welding without use of open e.g. prefabricated parts, roof drains,
́ Excellent weldability profiles. flames scuppers, walkway pads and decor
́ No risk of delamination or water- profiles.
wicking
́ Compatible to old bitumen
́ Recyclable

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
36 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 37
Sarnafil® T ROOF WATERPROOFING MEMBRANES

PRODUCT PROPERTIES

SERVICE  INFORMATION
Sarnafil® TS 77 DESCRIPTION APPEARANCE / COLOR Sarnafil® TS 77 E DESCRIPTION APPEARANCE / COLOR
Sarnafil® TS 77 is a polyester reinforced, Surface: Sarnafil® TS 77 E is a polyester reinforced, Surface:
multi-layer, synthetic roof waterproofing ́ Matt multi-layer, synthetic roof waterproofing ́ Matt
sheet based on flexible polyolefins (FPO) Top surface: sheet based on premium-quality flexible Top surface:
containing ultraviolet light stabilizers, ́ Beige polyolefins (FPO) containing ultraviolet ́ Beige
flame retardant and an inlay of glass ́ Window grey (RAL 7040) light stabilizers, flame retardant and an ́ Window grey (RAL 7040)
non-woven according to EN 13956. ́ Traffic white (RAL 9016) inlay of glass non-woven according to ́ Traffic white (RAL 9016)
Sarnafil® TS 77 is a hot air weldable roof Bottom surface: EN 13956. Bottom surface:
membrane formulated for direct expo- ́ Black Sarnafil® TS 77 E is a hot air weldable ́ Black
sure and designed to use in all global cli- roof membrane formulated for direct
matic conditions. Sarnafil® TS 77 is pro- Please check color policy exposure and designed to use in all Please check color policy

PRODUCT  INFORMATION
duced with an inlay of glass non-woven global climatic conditions. Sarnafil® TS
for dimensional stability and a polyester SYSTEM STRUCTURE 77 E is produced with an inlay of glass SYSTEM STRUCTURE
reinforcement for high strength. The following products must be consid- non-woven for dimensional stability The following products must be consid-
ered for use depending on roof design: and a polyester reinforcement for high ered for use depending on roof design:
USES ́ Sarnafil® T 66-15 D Sheet for detailing strength. ́ Sarnafil® T 66-15 D Sheet for detailing
Roof waterproofing membrane for: ́ Sarnafil® TS 77 strips ́ Sarnafil® TS 77 E strips
́ Mechanically fastened roofs ́ Sarnafil® T Metal Sheet USES ́ Sarnafil® T Metal Sheet
́ Sarnafil® T Welding Cord Roof waterproofing membrane for: ́ Sarnafil® T Welding Cord
CHARACTERISCTICS / ADVANTAGES ́ Sarnabar® / Sarnafast® ́ Mechanically fastened roofs ́ Sarnabar® / Sarnafast®
́ Proven performance over decades ́ Sarnafil® T Prep / Sarnafil® T Wet Task ́ Sarnafil® T Prep / Sarnafil® T Wet Task
́ Various colors available Set CHARACTERISCTICS / ADVANTAGES Set

APPLICATION  INSTRUCTIONS
́ Resistant to permanent UV exposure ́ Sarnacol® T 660 ́ Proven performance over decades ́ Sarnacol® T 660
́ High dimensional stability due to glass ́ Solvent T 660 ́ Various colors available ́ Solvent T 660
fleece inlay ́ Sarnafil® T Clean ́ Resistant to permanent UV exposure ́ Sarnafil® T Clean
́ Resistant to permanent wind expo- ́ High dimensional stability due to glass
sure Wide range of accessories is available fleece inlay Wide range of accessories is available
́ Resistant to all common environmen- e.g. prefabricated parts, roof drains, ́ Resistant to permanent wind expo- e.g. prefabricated parts, roof drains,
tal influences scuppers, walkway pads and decor sure scuppers, walkway pads and decor
́ Resistant to micro-organisms profiles. ́ Resistant to all common environmen- profiles.
́ Resistant to root penetration tal influences
́ Compatible to old bitumen ́ Resistant to micro-organisms
́ Hot air weldable ́ Compatible to old bitumen
́ Recycable ́ Hot air weldable
́ Recycable

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
38 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 39
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

DETAILING MEMBRANE METAL SHEET / COIL

SERVICE  INFORMATION
Sarnafil® T 66-15 D DESCRIPTION APPEARANCE / COLOR Sarnafil® T Metal Sheet / Coil DESCRIPTION APPEARANCE / COLOR
Sarnafil® T 66-15 D is an unreinforced Surface: Sarnafil® T Metal Sheet / Coil is a galvan- Surface:
multi-layer, synthetic roof waterproofing ́ Matt ised steel sheet or coil, laminated with ́ Smooth
sheet based on flexible polyolefins (FPO). Top surface: Sarnafil® T flexible polyolefin (FPO) roof Top surface:
Sarnafil® T 66-15 D is a hot air weldable, ́ Beige waterproofing membrane. ́ Beige
UV-resistant roof detailing membrane. ́ Window grey (RAL 7040) ́ Window grey (RAL 7040)
Bottom surface: USES ́ Other colors on request
USES ́ Beige Production of profiles for perimeter Bottom surface:
Detailing sheet for Sarnafil® T roof ́ Window grey (RAL 7040) fastenings and junctions: ́ Metal: cut (Epoxy-protection coated)
waterproofing membranes: ́ Other colors on request ́ Sarnafil® T (FPO) roof waterproofing
́ Welded to the installed Sarnafil® T membrane systems TECHNICAL INFORMATION

PRODUCT  INFORMATION
roof waterproofing membranes TECHNICAL INFORMATION Sarnafil® T Metal Sheet
Length: 20.00 m CHARACTERISTICS / ADVANTAGES Length: 2.00 m / 3.00 m
CHARACTERISTICS / ADVANTAGES Width: 0.50 m ́ Resistant to UV exposure Width: 1.00 m / 1.00 m
́ Resistant to permanent UV exposure Thickness: 1.50 mm ́ Can be cut and shaped either on site or Sarnafil® T Metal Coil
́ Resistant to most common environ- in metal workshop Length: 30.00 m
mental influences ́ Sarnafil® T lamination is hot air weld- Width: 1.00 m
́ Resistant to micro organisms able
́ Resistant to old bitumen Thickness:
́ Hot air welding without use of open Sarnafil® T lamination: 1.10 mm
flame Galvanised metal: 0.60 mm
́ Can be applied on either side as both Total thickness: 1.70 mm

APPLICATION  INSTRUCTIONS
surfaces have a different color

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
40 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 41
Sarnafil® T ACCESSORIES

WELDING PREPARATION /
CLEANERS

SERVICE  INFORMATION
Sarnafil® T Prep DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® Seam Preparation Cloths DESCRIPTION CHARACTERISTICS / ADVANTAGES
Mixture of organic solvents. ́ Ensures optimum seam quality The Sarnafil® Seam Preparation Cloths ́ No discoloration of the towels
́ Dissolves surface dirt consist of 150 white, solvent-resistant ́ Lint-free
USES ́ Evaporates quickly fleece cloths (6 × 25 cloths). ́ Significantly lower cleaner consump-
Sarnafil® T Prep is used to prepare seams ́ Highly flammable tion
of Sarnafil® TG and TS in order to ensure USES
optimum seam quality. The Sarnafil® seam preparation cloths
Sarnafil® T Prep is also suitable as are an aid for seam pretreatment and
general purpose cleaner to remove light possible cleaning. The cloths must be
dirt or bitumen residue from Sarnafil® TG changed during cleaning. Fresh cloths
and TS. should be used for seam pretreatment.

PRODUCT  INFORMATION
Wipes soaked with Sarnafil® T Clean
must not be used for seam pre-treat-
ment with Sarnafil® T Prep.

Sarnafil® Wet Task-Set DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Clean DESCRIPTION CHARACTERISTICS / ADVANTAGES
The Wet Task-Set includes a dispenser ́ Economical method of seam prepara- Mixture of organic solvents. ́ Dissolves surface dirt
bucket and a roll of 280 solvent-resistant tion, as clean, impregnated cloths are ́ Evaporates quickly
white cloth. always available USES ́ Suitable for heavily stained seam
́ Refillable Sarnafil® T Clean is a cleaner to remove overlaps of Sarnafil® T membranes

APPLICATION  INSTRUCTIONS
USES ́ No discoloration of the towels heavy soiling and adhesive residues from ́ Highly flammable
The set is filled with 5 litres of Sarnafil® ́ Lint-free Sarnafil® TG and TS membranes.
T Prep and the lid firmly closed. The cloth ́ Significantly lower cleaner consump- Sarnafil® T Clean is also suitabe for
removed through the dispenser open- tion cleaning tools and degreasing metal
ing are soaked with Sarnafil® T Prep for sheets.
economical seam preparation. A volume
fleece roll (refill towels) is offered for the
reusable dispenser bucket.

Solvent T-660 DESCRIPTION CHARACTERISTICS / ADVANTAGES


Mixture of high volatile solvents. ́ Optimal dilution/thinning of Sarnacol®
T-660 adhesive
USES ́ Dissolves contaminations and adhe-

STANDARD  DETAILS
Solvent T-660 is used to dilute Sarnacol® sive resin
T-660 adhesive and to remove adhesive ́ Evaporates quickly
residues from Sarnafil® T (FPO) mem- ́ Highly flammable
branes. It is also used for cleaning tools ́ Suitable to remove adhesive residues
and degreasing metal sheets. from seam
́ Overlaps of Sarnafil® T membranes

SUSTAINABLE  SOLUTIONS
42 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 43
Sarnafil® T ACCESSORIES

SOLVENT FREE CLEANERS

SERVICE  INFORMATION
SikaRoof® Clean Set Detail DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Clean Set Area DESCRIPTION CHARACTERISTICS / ADVANTAGES
SikaRoof® Clean Set Detail consists of ́ Fast and easy to use The SikaRoof® Clean Set Area consists of ́ Fast and easy to use
various cleaning items. ́ Water-based cleaning liquid various cleaning items.
́ Economical usage
USES USES
To clean small areas of polymeric mem- To clean polymeric membrane surfaces.
brane surfaces.

PRODUCT  INFORMATION
SikaRoof® Clean Pad Detail DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Clean Pad Area DESCRIPTION CHARACTERISTICS / ADVANTAGES
SikaRoof® Clean Pad Detail is a pad to ́ Fast and easy to use The SikaRoof® Clean Pad Area is a pad to ́ Fast and easy to use
clean polymeric roofing membranes. clean polymeric roofing membranes.

USES USES

APPLICATION  INSTRUCTIONS
To clean polymeric membrane surfaces To clean polymeric membrane surfaces
in combination with the SikaRoof® Clean in combination with the SikaRoof® Clean
Set Detail. Set Area.

SikaRoof® Clean Agent DESCRIPTION CHARACTERISTICS / ADVANTAGES


The SikaRoof® Clean Agent is a mild ́ Water-based
alkaline cleaning agent for roof water- ́ Economical usage
proofing membranes.

STANDARD  DETAILS
USES
To clean polymeric membrane surfaces
in combination with the SikaRoof® Clean
Set Detail and area.

SUSTAINABLE  SOLUTIONS
44 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 45
Sarnafil® T ACCESSORIES

ADHESIVES, PRIMERS
AND SEALANTS

SERVICE  INFORMATION
Sarnacol® T-660 DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Tape P DESCRIPTION CHARACTERISTICS / ADVANTAGES
Butyl rubber based one-pack contact ́ Adheres to solid, rough and clean SikaRoof® Tape P is a polyacrylate ́ High tack and long-term adhesion
adhesive. surfaces double-sided adhesive tape used with ́ Finger-lift release liner
Sarnafil® T roof membranes. ́ Contains no halogen or heavy-metal
USES SikaRoof® Tape P may only be used by compounds
To bond Sarnafil® TG 66 and TS 77 mem- experienced professionals. ́ Easily applied
branes in perimeter and flashing areas.
USES TECHNICAL INFORMATION
Bonds Sarnafil® T roofing membranes to Length: 25.00 m
a range of upstand substrates. Width: 115.00 mm
Thickness: Overall 0.50 mm

PRODUCT  INFORMATION
Sarnacol®-2142 S / -2142 V DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Board Adhesive DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnacol®-2142 S is a 1-part, polyure- ́ Proven performance over decades. SikaRoof® Board Adhesive is a polyure- ́ Easy, efficient and clean application
thane based moisture curing adhesive. ́ Adheres to solid, rough, clean, dry or thane 1- part, fast curing, gun grade, with spray application gun
slightly moist surfaces foam adhesive that bonds insulation ́ One container covers an area of up to
Sarnacol®-2142 V is a VOC free, 1-part, ́ Application by roller boards to various types of construction ~13 m²

APPLICATION  INSTRUCTIONS
polyurethane based moisture curing ́ Good adhesion to different substrates material substrates. ́ Fast moisture curing for quick bonding
adhesive. ́ VOC free (Sarnacol®-2142 V) ́ Fire Behaviour B1 class (DIN 4102-1)
USES ́ Good adhesive tensile strength
USES Insulation board types: ́ Adheres to solid, clean, dry or slightly
Bonding Sarnafil® T Felt-type mem- ́ Extruded polystyrene boards (XPS) moist surfaces
branes to roof substrates. ́ Expanded polystyrene boards (EPS) ́ HFC-free
́ PUR/PIR boards
́ Mineral fibre boards with sufficient
compressive strength and appropriate
type of bonding surface

Sarnacol®-2116 DESCRIPTION USES


Sarnacol®-2116 is a water based 1-part Binder for binding gravel on horizontally
synthetic resin based adhesive. applied Sarnafil® T membranes (not for
bonding).

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
46 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 47
Sarnafil® T ACCESSORIES

ADHESIVES, PRIMERS
AND SEALANTS

SERVICE  INFORMATION
Sika® Primer-3 N DESCRIPTION CHARACTERISTICS / ADVANTAGES Primer T-501 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sika® Primer-3 N is a solvent-based, ́ Easy to apply Primer T-501 is a 1-part, ready to use, ́ 1-part ready to use
1-component primer. ́ Water repellent solvent-based, polymeric primer for ́ Easily applied by brush
́ Short flash-off time improving the adhesion properties of ́ High adhesion to different structural
USES absorbent substrates. decks and substrates
Sika® Primer-3 N is designed for
Sikaflex®, SikaHyflex®, SikaBond® and USES
Sikasil® products used on porous sub- Primer T-501 may only be used by experi-
strates (e.g. concrete) and metals. enced professionals.
Primer:
́ Application of Sarnaplast®-2235

PRODUCT  INFORMATION
onto absorbent substrates / metals /
Sarnafil® T
́ Application of Sikagard®-950 on
Sarnafil® T

Primer-780 DESCRIPTION CHARACTERISTICS / ADVANTAGES S-Sealing Tape 10/10 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Water based dispersion primer. ́ Solvent free S-Sealing Tape 10/10 is a polyurethane, ́ Easily applied strip with integral adhe-
́ Fast drying single-sided adhesion soft foam sealing sive and release liner
USES ́ High adhesion to different structural tape with acrylate dispersion impregna- ́ Finger-lift release liner
Primer-780 is a ready to use product, decks and substrates tion.

APPLICATION  INSTRUCTIONS
used for applying self-adhered Mem- ́ Application at 5 °C APPEARANCE / COLOR
brane: USES Color:
́ Sarnafil® TG 76 FSA onto various Placed between laminated metal sheet ́ Grey
substrates flashings and the substrate to prevent ́ Black
the penetration of wind driven water.
TECHNICAL INFORMATION
Length: 25.00 m
Width: 10 mm
Thickness: 10 mm

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
48 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 49
Sarnafil® T ACCESSORIES

ADHESIVES, PRIMERS
AND SEALANTS

SERVICE  INFORMATION
Sikaflex®-11 FC+ DESCRIPTION CHARACTERISTICS / ADVANTAGES RELEASED / APPROVED APPLICATIONS FOR SEALANTS
Sikaflex®-11 FC+ is a 1-part, multipurpose ́ Movement capability of ±35 %
Sikaflex®-11 FC+ Sarnaplast®-2235 SikaBond® TF plus N
elastic adhesive and joint sealant with ́ Bonds well to defined substrates with-
very good application properties which out surface pre-treatment Application Various Various EPDM Connection
bonds and seals most construction ma- ́ Good mechanical and weathering
Sarnafil® TG 66 / TS 77 Sikalastic® Primer FPO Primer T-501 Sikalastic® Primer FPO
terial substrates. Internal and external resistance Membranes
use. ́ Very low emissions and Metal Sheets Sarnafil® T Metal Sheet Solvent T-660
None None
́ Adhesive-sealant with CE marking (Bottom surface) (Sarnafil® T Clean)
USES
Concrete, natural stone Sika® Primer-3 N Primer T-501 Sika® Primer-3 N
An adhesive to bond construction com-
ponents and materials such as:

PRODUCT  INFORMATION
Fibre cement Sika® Primer-3 N Primer T-501 Sika® Primer-3 N
́ Concrete
́ Masonry Copper Not tested Not tested Not tested
́ Reconstituted or cast stone Abrasive treatment + Abrasive treatment +
́ Ceramic Aluminium uncoated Primer T-501
Substrates Sika® Activator-205 Sika® Activator-205
́ Wood
́ Metal Alumium anodised Sika® Activator-205 Primer T-501 Sika® Activator-205
́ Glass Titanium zinc Sika® Activator-205 Primer T-501 Sika® Activator-205
́ A sealant to seal vertical and horizontal
joints Steel Sika® Activator-205 Primer T-501 Sika® Activator-205

EPDM Not compatible Not compatible None

APPLICATION  INSTRUCTIONS
Sarnaplast®-2235 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnaplast®-2235 is a 1-part transparent ́ Resistant to UV exposure
elastomeric silicone sealant for sealing ́ Application onto rough and smooth
connection details on Sarnafil® flat roof substrates
systems. ́ Bonds to most construction materials
́ Applied using standard sealant gun
USES
Sarnaplast®-2235 may only be used by
experienced professionals.
A Sealant to seal:
́ Flashing joints
́ Expansion joints
́ Perimeter flashings

STANDARD  DETAILS
SikaBond® TF plus N DESCRIPTION CHARACTERISTICS / ADVANTAGES
SikaBond® TF plus N is a 1-component, ́ Secure application with good sag
PU-based adhesive for the SikaMembran® resistance bonds well to concrete, alu-
facade membrane system, which com- minium (anodized or powder-coated),
bines high mechanical strength with the rigid U-PVC, timber and other standard
necessary elasticity to cope with high construction materials
movements in facades. SikaBond® TF ́ Application of adhesive to one side
plus N adheres excellent to a wide range only (mostly to substrate)
of substrates. ́ Ensures levelling of substrate

SUSTAINABLE  SOLUTIONS
́ No contact pressure necessary
USES ́ Fast curing adjustment of membrane
This product is suitable for experienced possible until 30 min. after installation
professional users only. Test with actual
substrates and conditions have to be
performed to ensure adhesion and mate-
rial compatibility.

50 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 51


Sarnafil® T ACCESSORIES

PREFABRICATED PRODUCTS

SERVICE  INFORMATION
Sarnafil® T Preformed DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Post Flashing DESCRIPTION CHARACTERISTICS / ADVANTAGES
Components CI / WA The Sarnafil® T Preformed Components ́ Resistant to UV exposure Sarnafil® T Post Flashing is a prefabri- ́ Resistant to UV exposure
corner are made of homogeneous flex- ́ Ease and safe application cated roof post flashing based on an FPO ́ Ease and safe application
ible polyolefins by injection moulding. ́ Hot air weldable waterproofing membrane. ́ Hot air weldable

USES APPEARANCE / COLOR USES APPEARANCE / COLOR


The Sarnafil® T Preformed Components Surface: Sarnafil® T Post Flashing may only be Surface:
parts (inner and outer corners) are used: ́ Smooth used by experienced professionals. ́ Smooth
́ In the connection area of the Sarnafil® Top surface: ́ Post flashing on Sarnafil® T flat roof Top surface:
flat roof systems ́ Beige systems ́ Beige
́ Window grey (RAL 7040) ́ Window grey (RAL 7040)

PRODUCT  INFORMATION
́ Other colors on request ́ Other colors on request

Sarnafil® T Corner 90° I / A DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sarnafil® T Corner 90° I / A is based on ́ Resistant to UV exposure
flexible polyolefins (FPO) manufactured ́ Ease and safe application
by injection moulding. ́ Hot air weldable

APPLICATION  INSTRUCTIONS
USES APPEARANCE / COLOR
Sarnafil® T Corner 90° I / A may only be Surface:
used by experienced professionals. ́ Smooth
́ Prefabricated corners for Sarnafil® T Top surface:
flat roof systems ́ Beige
́ Window grey (RAL 7040)
́ Other colors on request

Sarnafil® T Pipe Flashing DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Lightning DESCRIPTION APPEARANCE / COLOR
Sarnafil® T Pipe Flashing is made of ́ Resistant to UV exposure Conductor Flashing Sarnafil® T Lightning Conductor Flash- Surface:
synthetic roof waterproofing membrane ́ Ease and safe application ing is made of premium-quality flexible ́ Smooth
based on premium-quality flexible poly- ́ Hot air weldable polyolefin (FPO) by injection moulding Top surface:
olefins (FPO), containing stabilizers, with procedure. ́ Beige
inlay of glass non-woven. APPEARANCE / COLOR ́ Window grey (RAL 7040)
Surface: USES ́ Other colors on request

STANDARD  DETAILS
USES ́ Smooth Sarnafil® T Lightning Conductor Flashing
Sarnafil® T Pipe Flashing is used as a Top surface: is used as a prefabricated part for: TECHNICAL INFORMATION
prefabricated part for: ́ Beige ́ Lightning Conductor Flashing on Diameter base plate: 160 mm
́ Pipe / vent flashing on Sarnafil® T flat ́ Window grey (RAL 7040) Sarnafil® T flat roof systems Inside pipe diameter
roof systems ́ Other colors on request conical: 11.00 – 15.00 mm
CHARACTERISTICS / ADVANTAGES Height: 250 mm
́ Resistant to UV exposure Thickness: 2.00 mm
́ Ease and safe application
́ Hot air weldable
́ Product is delivered incl. shrink hose

SUSTAINABLE  SOLUTIONS
52 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 53
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

PREFABRICATED PRODUCTS ROOF DRAINAGE

SERVICE  INFORMATION
Sarnafil® T Lightning DESCRIPTION APPEARANCE / COLOR Sarnafil® T Gully Set DESCRIPTION CHARACTERISTICS / ADVANTAGES
Conductor Circus Sarnafil® T Lightning Conductor Circus is Surface: The Sarnafil® T Gully Set is a prefabricat- ́ Resistant to UV exposure
a flexible polyolefin (FPO) lightning con- ́ Matt ed rigid polypropylene rainwater outlet ́ Membrane can be welded directly to
ductor clip connecting disc formed from Color: for flat roofs used with Sarnafil® T roof- the base plate
FPO waterproofing membrane. Top surface: ing membranes. It is also available with ́ Hot air weldable
́ Beige a combined heating system. ́ Vapour control layer can be connected
USES Bottom surface: to the base plate to form an airtight
This product may only be used by experi- ́ Beige USES seal
enced professionals: The Sarnafil® T Gully Set may only be
́ Connects S-Lightning Conductor Clips TECHNICAL INFORMATION used by experienced professionals: APPEARANCE / COLOR
and S-Lightning Conductor Clips (V2A) Diameter: 200 mm ́ Rainwater outlet for use with Sar- Surface:

PRODUCT  INFORMATION
to Sarnafil® TG / TS membranes roof Centre hole diameter: 23 mm nafil® T roofing membranes ́ Smooth
membranes Thickness: 1.50 mm Color:
́ Beige
CHARACTERISTICS / ADVANTAGES
́ Resistant to UV exposure
́ Hot air weldable without the use of
open flames

S-Lightning Conductor Clip DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Gully DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Lightning Conductor Clip is a poly- ́ Resistant to UV exposure Horizontal / Vertically The Sarnafil® T Gully is made of high ́ Simple electrical connection

APPLICATION  INSTRUCTIONS
amide / Nylon (PA) clip for securing ́ Suitable for Sarnafil® FPO flat roof quality pressure stable polyolefin injec- ́ Sarnafil® T waterproofing membranes
lightning conductor cables to Sarnafil® systems tion moulding. The product is available can be welded directly to the flange
roof membranes. with or without heating. ́ Easy application
APPEARANCE / COLOR ́ Meets the standards of DIN EN 1253
USES Top surface: The Sarnafil® T Gully consists of:
S-Lightning Conductor Clip may only be ́ Grey ́ Sarnafil® T Gully, thermally insulated, APPEARANCE / COLOR
used by experienced professionals: incl. built-in backwater seal Surface:
́ S-Lightning Conductor Clip is used as TECHNICAL INFORMATION ́ Gravel basket ́ Smooth
lightning conductor clip on flat roofs. Base plate: Ø 110 mm Color:
Suitable for conductor Ø 8 mm – 10 mm Height: 45 mm USES ́ Beige
The Sarnafil® T Gully is used for drainage
of flat roofs. TECHNICAL INFORMATION
Electrical connection:
Main Voltage: 230 V
S-Lightning Conductor Clip V2A DESCRIPTION CHARACTERISTICS / ADVANTAGES Connected load: 15 Watt
S-Lightning Conductor Clip V2A is a ́ Resistant to UV exposure

STANDARD  DETAILS
stainless steel clip on a polyamide / nylon ́ Suitable for Sarnafil® FPO flat roof
support base which is used for securing systems
lightning conductor cables to Sarnafil®
roof membranes. APPEARANCE / COLOR
Top surface:
USES ́ Grey
This product may only be used by experi-
enced professionals: TECHNICAL INFORMATION
́ Lightning conductor cable clip for flat Base plate: Ø 110 mm
roofs with conductor cable diameters Height: 40 mm

SUSTAINABLE  SOLUTIONS
in the range of 8 mm to 10 mm

54 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 55


Sarnafil® T ACCESSORIES

ROOF DRAINAGE

SERVICE  INFORMATION
Sarnafil® T Drain DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Overflow – square DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® T Drain is an FPO (PP) pre- ́ Resistant to UV exposure Sarnafil® T Overflow – square is a pre- ́ Resistant to UV exposure
fabricated injection moulded rainwater ́ Membrane can be welded directly onto fabricated rigid FPO overflow outlet for ́ Membrane can be welded directly to
outlet for flat roofs. Outlet is used with the base plate flat roofs. the base plate
Sarnafil® T roofing membranes which are ́ Ease of application ́ Hot air weldable
heat welded onto the baseplate. ́ Hot air weldable USES
This product may only be used by experi- APPEARANCE / COLOR
USES APPEARANCE / COLOR enced professionals: Surface:
Sarnafil® T Drain may only be used by Surface: ́ Overflow outlet through flat roof para- ́ Smooth
experienced professionals: ́ Smooth pets for use with Sarnafil® T roofing Top surface:
́ Rainwater outlet for use with Sar- Top surface: membranes ́ Silk grey (nearest RAL 7044)

PRODUCT  INFORMATION
nafil® T roofing membranes ́ Beige

S-Gully Overflow screw-on device DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Scupper – round DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Gully Overflow screw-on device is a ́ Resistant to UV exposure Sarnafil® T Scupper – round is a rigid ́ Resistant to UV exposure
polypropylene (PP) flat roof gully over- ́ Height adjustable from 30 mm to 65 polyolefin prefabricated injection moulded ́ Membrane can be welded directly to
flow manufactured by injection moulding. mm rainwater outlet for flat roofs used with the base plate
́ Easily inserted into top of gully Sarnafil® T roof waterproofing mem- ́ Ease of application

APPLICATION  INSTRUCTIONS
USES branes which can be heat welded onto ́ Hot air weldable
This product may only be used by experi- APPEARANCE / COLOR the drain.
enced professionals: Surface: APPEARANCE / COLOR
́ An overflow screw-on device for ́ Smooth USES Surface:
Sarnafil® T Gully, Sarnafil® T add-on Top surface: Rainwater outlet through the parapet for ́ Smooth
element Ø 125 flat roofs systems ́ Red / black use with Sarnafil® T roofing membranes. Top surface:
́ Beige

Sarnafil® T Overflow – round DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Drain DESCRIPTION CHARACTERISTICS / ADVANTAGES
The Sarnafil® T Overflow – round has a ́ Sarnafil® T roof waterproofing mem- Inspection chamber SikaRoof® Drain inspection chamber is ́ Easy to install
straight tray and is made of high-quality branes can be welded directly to the a high density fibre reinforced concrete ́ Insulated lid
pressure-resistant PP (polypropylene) flange inspection chamber for accessing drains

STANDARD  DETAILS
injection moulding. ́ Easy applicationg on green roofs. APPEARANCE / COLOR
́ Special lengths available on request Surface:
USES USES ́ Smooth
The Sarnafil® T Overflow – round is used: APPEARANCE / COLOR SikaRoof® Drain inspection chamber may Top surface:
́ For flat roof waterproofing as an Surface: only be usedby experienced professionals: ́ Brown
emergency overflow with horizontal ́ Smooth ́ Accessing drains on green roofs
pipe penetration through roof edge Top surface: TECHNICAL INFORMATION
upstands ́ Beige Frame: 350 mm × 350 mm × 120 mm
Thickness: 10 mm
Lid insulation: 20 mm XPS board

SUSTAINABLE  SOLUTIONS
56 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 57
Sarnafil® T ACCESSORIES

ROOF DRAINAGE

SERVICE  INFORMATION
S-Leafguard round DESCRIPTION CHARACTERISTICS / ADVANTAGES Gravel Frame with DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Leafguard round is a prefabricated ́ Resistant to UV exposure adjustable put on frame Gravel Frame with adjustable put on ́ Adjustable height: 50 – 80 mm
Polypropylene (PP) basket with fixing ́ Ease of application frame is a stainless steel gravel frame ́ Ease of application over gulley
wing nut. with adjustable insert (put on frame) for
APPEARANCE / COLOR ballasted terraces. APPEARANCE / COLOR
USES Surface: Surface:
This product may only be used by experi- ́ Smooth USES ́ Smooth
enced professionals: Gravel protection for roof drains in bal- Top surface:
́ The S-Leafguard round is used as a TECHNICAL INFORMATION lasted flat roof systems. ́ Stainless steel
gravel and leaf protection for Sarnafil® Basket outside diameter: 237 mm
T-Drains in flat roofs Basket height: 82 mm TECHNICAL INFORMATION

PRODUCT  INFORMATION
Dimensions: 200 × 200 × 50 – 80 mm
Thickness: 1.00 mm

S-Gravel Frame stainless steel DESCRIPTION CHARACTERISTICS / ADVANTAGES Perforated strainer DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Gravel Frame stainless steel is a ́ Ease of application over gulley Perforated strainer is a prefabricated, ́ Easily placed into gulley frame
stainless steel gravel frame for ballasted stainless steel, strainer for ballasted roof
terraces. APPEARANCE / COLOR drainage systems. APPEARANCE / COLOR
Surface: Surface:

APPLICATION  INSTRUCTIONS
USES ́ Smooth USES ́ Smooth
Gravel protection for roof drains in bal- Top surface: This product may only be used by experi- Color:
lasted flat roof systems. ́ Stainless steel enced professionals: ́ Stainless steel
́ Perforated strainer for the Sika Gravel
TECHNICAL INFORMATION Frame with adjustable frame insert TECHNICAL INFORMATION
Dimensions: 200 × 200 × 40 / 60 mm (put on frame) Dimensions: 195 × 195 × 20 mm
Thickness: 2.00 mm Thickness: 1.00 mm

S-Grid stainless steel DESCRIPTION CHARACTERISTICS / ADVANTAGES S-Duoseal Couplings DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Grid stainless steel is a prefabricated, ́ Easily placed into gulley frame The S-Duoseal Couplings is made of eth- ́ Ease of application
stainless steel, grid for ballasted roof ylene propylene diene monomer rubber ́ Secure and durable backflow seal
drainage systems. APPEARANCE / COLOR (EPDM) by injection moulding procedure. ́ Each S-Duoseal Couplings fits a wide
Surface: range of sizes
USES ́ Smooth USES

STANDARD  DETAILS
S-Grid stainless steel may only be used Top surface: The S-Duoseal Couplings is used with
by experienced professionals: ́ Stainless steel Sarnafil® T Drain.
́ Insert grid for the S-Gravel Frame ́ It provides an economic method of
TECHNICAL INFORMATION solving the problem of sealing a new
Dimensions: 190 × 190 × 20 mm Sarnafil® T Drain into an existing roof
Thickness: 1.50 / 2.00 mm drain during a roof refurbishment.

SUSTAINABLE  SOLUTIONS
58 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 59
Sarnafil® T ACCESSORIES

ANCILLARY COMPONENTS

SERVICE  INFORMATION
SikaRoof® Cable Duct-110 DESCRIPTION CHARACTERISTICS / ADVANTAGES Paving support Pad/ levelling shim DESCRIPTION CHARACTERISTICS / ADVANTAGES
SikaRoof® Cable Duct-110 is a PE-HD pre- ́ Constructed of durable PE-HD Paving support Pad/ levelling shim is a ́ Ease of application
fabricated pipe bend with sliding socket ́ Proven waterproofing detail prefabricated high density polyethylene ́ Resistant to UV exposure
and protection lid. ́ Easily connected over roof penetration (HD-PE) paving support pad manufac- ́ Correctly positions paving slabs
tured by injection moulding. It enables ́ Securely holds paving slabs in place
USES APPEARANCE / COLOR the correct positioning of paving slabs ́ Uniform spacing between paving slabs
This product may only be used by experi- Top surface: and provides water drainage between ́ Very good water drainage between
enced professionals: Pipe bend with sliding socket: and underneath the slabs. slabs and below the paving level
́ Provides a watertight cable bushing ́ Black ́ Paving not fixed, allowing slabs to be
detail on exposed roofs USES removed easily
TECHNICAL INFORMATION Paving support Pad/ levelling shim may

PRODUCT  INFORMATION
Dimension pipe diameter: 110 mm only be used by experienced professionals: APPEARANCE / COLOR
́ Placement of paving slabs on flat Top surface:
roofs, plaza decks, balconies, veran- ́ Black
das, courtyards, terraces etc.
TECHNICAL INFORMATION
Paving support pad 1/20 with cross:
S-Gravelstop Profile DESCRIPTION CHARACTERISTICS / ADVANTAGES Joints
S-Gravelstop Profile is a perforated ́ Stainless Steel Length × width: 105 × 105 mm
stainless steel gravel stop profile for bal- ́ Suitable for FPO ballasted roofing Thickness: 9.50 mm
lasted flat roofs. systems Height of lug: 20 mm
Thickness of lug: 5.00 mm

APPLICATION  INSTRUCTIONS
USES APPEARANCE / COLOR Length of cross lug: 58.50 mm
Gravel stop at roof perimeters in bal- Surface:
lasted roofing systems or other ballast ́ Smooth Paving levelling shim
free roof areas: Top surface: Length × width: 106 × 106 mm
́ Separation profile between different ́ Stainless steel Thickness: 2.00 mm
types of roof ballast
TECHNICAL INFORMATION
Height: 60 / 100 mm
Length: 3000 mm
Width: 30 mm

Sarnafil® T Gravelstop bracket DESCRIPTION CHARACTERISTICS / ADVANTAGES Snow guard holder galvanized DESCRIPTION USES
Sarnafil® T Gravelstop bracket is a ́ Sarnafil® T FPO membrane on corro- Two-piece galvanized steel bracket for Snow protection system with double
prefabricated bracket to fasten the sion resistant stainless steel bracket ¾ inch tubes, mounted in a row and pipe passage (drill holes) to protect
S-Gravelstop Profile to Sarnafil® T (FPO) ́ Suitable for ballasted roofing systems evenly spaced horizontally. The bottom against the sliding of snow masses on

STANDARD  DETAILS
roof waterproofing membranes by heat ́ Easy application without penetrating part (base plate) is fixed in the substruc- flat sloping roofs.
welding and without penetrating the the membrane ture. The upper part (sword) is screwed
membrane. ́ Hot air weldable through the sealing in the base plate and CHARACTERISTICS / ADVANTAGES
receives pipes in the snow guard system ́ For heavier snow loads
USES APPEARANCE / COLOR with two holes arranged one above the ́ Resistant to environmental influences
Sarnafil® T Gravelstop bracket may only Top surface: other.
be used by experienced professionals: Membrane: The snow guard holder consists of:
́ Fastening the S-Gravelstop Profile to ́ Beige ́ Stainless steel base plate with safety
Sarnafil® T (FPO) roof waterproofing Top surface: nuts M8
membranes with slopes of < 5° Bracket: ́ Galvanized or powder-coated snow

SUSTAINABLE  SOLUTIONS
́ Stainless steel catcher Sword
́ Two seals NBR, 150 × 100 mm
TECHNICAL INFORMATION to be ordered separately
Outside Bracket / Inside Bracket
Length: 150 mm / 120 mm
Width: 140 mm / 140 mm
Height: 120 mm / 120 mm

60 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 61


Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

ANCILLARY COMPONENTS WALKWAYS

SERVICE  INFORMATION
Snow guard stainless steel DESCRIPTION USES Sarnafil® T Walkway Pad DESCRIPTION CHARACTERISTICS / ADVANTAGES
Two-piece stainless steel bracket for ¾ Snow protection system with double Sarnafil® T Walkway Pad is made of ́ Resistant to UV exposure
inch tubes or 1 inch tubes mounted in a pipe passage (drill holes) to protect premium-quality flexible polyolefin (FPO) ́ Slip resistant surface
row and evenly spaced horizontally. The against the sliding of snow masses on by injection moulding procedure. ́ Hot air weldable
lower part (base plate) is fixed in the flat sloping roofs. ́ Rainwater drainage from beneath the
substructure. The upper part (sword) USES Sarnafil® T
is screwed together by the seal in the CHARACTERISTICS / ADVANTAGES Sarnafil® T Walkway Pad is used: ́ Walkway Pad is provided by a network
base plate and accommodates pipes in ́ Light weight ́ To provide a durable slip resisting walk- of moulded channels
the snow guard system with two holes ́ Resistant to environmental influences way for roof maintenance or access on
arranged one above the other. any Sarnafil® T roofing system APPEARANCE / COLOR
Surface:

PRODUCT  INFORMATION
The snow guard consists of: ́ Chevron pattern with an alternating rib
́ Base plate with safety nuts M8 height of the embossing
́ Snow catcher sword Top surface:
́ Two seals NBR, 90 × 50 mm ́ Dark grey
to be ordered separately
TECHNICAL INFORMATION
Length: 600 mm
Width: 600 mm without welding tabs
Thickness: 9.30 mm Including 3/5 mm non
slip chevron pattern embossing

APPLICATION  INSTRUCTIONS
Sarnafil® T TuffLane 40 YB DESCRIPTION APPEARANCE / COLOR
Sarnafil® T TuffLane 40 YB is a walkway / Surface:
protection sheet based on flexible fibrous ́ Herringbone embossed pattern
mixture of polyolefins (FPO) containing Top surface:
ultraviolet light stabilizers and flame ́ White (nearest RAL 9010)
retardant. Border:
́ Approx. 50 – 60 mm yellow safety edge
USES Bottom surface:
Sarnafil® T TuffLane 40 YB is used as a ́ White (nearest RAL 9010)
protection layer on top of Sarnafil® T roof
waterproofing membrane without ballast TECHNICAL INFORMATION
as a frequent walkway for roof mainte- Length: 15.00 m
nance. Width: 0.76 m
Thickness: 4.00 mm (incl. embossing)
CHARACTERISTICS / ADVANTAGES 2.00 mm (depth of embossing)

STANDARD  DETAILS
́ Applicable for exposed roofing
́ Good slip resistant surface due to
embossed surface
́ Innovative yellow safety border
technology
́ Ease of application
́ Hot air weldable

SUSTAINABLE  SOLUTIONS
62 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 63
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

WALKWAYS CONNECTION SYSTEM

SERVICE  INFORMATION
Sarnafil® TG-20 WW DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafil® T Dilatec® ER-300 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® TG-20 WW is a protection ́ Applicable for exposed roofing Sarnafil® T Dilatec® ER-300 is a flexible, ́ Resistant to UV exposure
sheet based on flexible polyolefins (FPO) ́ Ease of application multi-layer, flexible polyolefin (FPO), seal- ́ High dimensional stability from glass
with inlay of glass non-woven contain- ́ Hot air weldable ing tape containing stabilisers, a glass fleece inlay
ing ultraviolet light stabilizers and flame fleece non-woven inlay and a single-sided ́ Resistance to all common environ-
retardant. APPEARANCE / COLOR fabric strip. It is bonded on one side with mental influences
Surface: Sikadur Combiflex® CF Adhesive Normal ́ Heat weldable
USES ́ Texturized or Rapid and welded on the other side ́ No open flame equipment required
́ Sarnafil® TG-20 WW is used as a Top surface: (without fabric strip) to the Sarnafil® T
protection layer on top of Sarnafil® T ́ Grey (nearest RAL 7040) roof waterproofing membrane.
roof waterproofing membrane without Bottom surface:

PRODUCT  INFORMATION
ballast as a frequent walkway for roof ́ Dark grey USES
maintenance. Sarnafil® T Dilatec® ER-300 may only be
TECHNICAL INFORMATION used by experienced professionals:
Length: 20.00 m ́ End tape for Sarnafil® T roof water-
Width: 0.66 m proofing membranes on concrete and
Thickness: 2.00 mm (incl. embossing) metal substrates
0.30 mm (depth of embossing)

Sikadur Combiflex® CF DESCRIPTION CHARACTERISTICS / ADVANTAGES


Adhesive Normal / Rapid Sikadur Combiflex® CF Adhesive Normal / ́ Easy to mix and apply
Rapid is a 2-part epoxy based thixotropic ́ Excellent adhesion to many materials

APPLICATION  INSTRUCTIONS
adhesive for bonding the modified flex- ́ Performs well within a wide tempera-
ible Polyolefin (FPO) waterproofing tapes ture range
Sarnafil T Dilatec® ER-300 to different ́ Good resistance to many chemicals
substrates. Internal and external use. ́ No primer needed
́ High mechanical resistance
USES
Adhesive for the Sarnafil T Dilatec® ER- APPLICATION TEMPERATURE
300 system. Normal: +10 °C to +30 °C
Rapid: +5 °C to +15 °C

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
64 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 65
Sarnafil® T ACCESSORIES

FASTENING PRODUCTS

SERVICE  INFORMATION
Sarnafast® Washer KTL DESCRIPTION CHARACTERISTICS / ADVANTAGES
Zinc plated steel washer with diamond- ́ Lightweight
shaped reinforcement and specially ́ Resistance against common environ-
stamped barbs for the mechanical mental influences
fastening of roof waterproofing mem- ́ Easy application in use with recom-
branes. mended setting tools
́ Recyclable
USES
Mechanically fastened roof waterproo- TECHNICAL INFORMATION
fing membranes by Sarnafast® spot Dimension: 82 × 40 mm
fastening in overlaps and / or interme- Hole diameter: 7.50 mm

PRODUCT  INFORMATION
diate spot fastening in combination Thickness: 1.00 mm
with Sarnafast® Fastener SBF-6.0 on all Corrosion resistance:
decks. Only for fastening roof water- 15 cycles according to Kesternich
proofing membranes over compressible
thermal insulation (not for use on hard
substrates).

Sarnafast® Washer KT DESCRIPTION CHARACTERISTICS / ADVANTAGES


Zinc plated steel washer with diamond- ́ Lightweight
shaped reinforcement and specially ́ Resistance against common environ-

APPLICATION  INSTRUCTIONS
stamped barbs for the mechanical mental influences
fastening of roof waterproofing mem- ́ Easy application in use with recom-
branes. mended setting tools
́ Recyclable
USES
Mechanically fastened roof waterproof- TECHNICAL INFORMATION
ing membranes by Sarnafast® spot fas- Dimension: 82 × 40 mm
tening in overlaps and / or intermediate Hole diameter: 4.90 mm
spot fastening in combination with Sar- Thickness: 1.00 mm
nafast® Fastener SF-4.8 on corrugated Corrosion resistance:
steel and solid wood decks. Only for fas- 15 cycles according to Kesternich
tening roof waterproofing membranes
over compressible thermal insulation
(not for use on hard substrates).

STANDARD  DETAILS
Sarnafast® Washer IF/IG-C DESCRIPTION CHARACTERISTICS / ADVANTAGES
Zinc plated steel washer for the me- ́ Lightweight
chanical fastening of roof waterproofing ́ Resistance against common environ-
membranes. mental influences
́ Easy application in use with recom-
USES mended setting tools
Mechanically fastened roof waterproof- ́ Recyclable
ing membranes by Sarnafast® spot
fastening in overlaps and / or intermedi- TECHNICAL INFORMATION
ate spot fastening in combination with Dimension: 82 × 40 mm

SUSTAINABLE  SOLUTIONS
Sarnafast® Fastener SF-4.8 on corru- Hole diameter: 7.50 mm
gated steel and solid wood decks or Sar- Thickness: 1.00 mm
nafast® Fastener SBF-6.0 on all decks. Corrosion resistance:
Only for fastening roof waterproofing 15 cycles according to Kesternich
membranes over hard substrates.

ROOFING HANDBOOK Sarnafil® T 67


Sarnafil® T ACCESSORIES

FASTENING PRODUCTS

SERVICE  INFORMATION
Sarnafast® Tube SFT-50 DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafast® Insulation Washer DTL DESCRIPTION CHARACTERISTICS / ADVANTAGES
Polyamide tube (PA 6) with teeths ́ Lightweight Zinc plated steel washer for the mechan- ́ Lightweight
for the mechanical fastening of roof ́ Resistance against common environ- ically fastening of thermal insulation. ́ Resistance against common environ-
waterproofing membranes and thermal mental influences mental influences
insulation. ́ Easy application in use with recom- USES ́ Easy application in use with recom-
mended setting tools Mechanically fastened thermal insula- mended setting tools
USES ́ Recyclable tion in combination with Sarnafast® ́ Recyclable
Mechanically fastened roof waterproof- Fastener SBF-6.0 on all decks.
ing membranes by Sarnafast® spot TECHNICAL INFORMATION TECHNICAL INFORMATION
fastening in overlaps and / or inter- Diameter: 55 mm (at collar) Dimension: 70 × 70 mm
mediate spot fastening in combination Available lengths: 40 – 300 mm Hole diameter: 7.50 mm

PRODUCT  INFORMATION
with Sarnafast® Fastener SBF-6.0 on all Hole diameter: 13 mm Thickness: 1.00 mm
decks. Only for fastening roof water- Corrosion resistance: Corrosion resistance:
proofing membranes over compressible 30 h conditioned in conditioning cell 15 cycles according to Kesternich
thermal insulation (not for use on hard
substrates). Further for the mechanical
fastening of thermal insulation boards.

Sarnafast® DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafast® Insulation Washer DT DESCRIPTION CHARACTERISTICS / ADVANTAGES
Row Termination Plate RTL Zinc plated steel washer for the row ́ Better load distribution and reduces Zinc plated steel washer for the mechan- ́ Lightweight
termination in the mechanically fastened risk of a failure in the membrane ically fastening of thermal insulation.. ́ Resistance against common environ-

APPLICATION  INSTRUCTIONS
roof system. ́ Lightweight mental influences
́ Resistance against common environ- USES ́ Easy application in use with recom-
USES mental influences Mechanically fastened thermal insulation mended setting tools
Termination of row of intermediate ́ Easy application in use with recom- in combination with Sarnafast® Fastener ́ Recyclable
spot fastening system with four pieces mended setting tools SF-4.8 on corrugated steel and solid
Sarnafast® Fastener SBF-6.0 on all ́ Recycable wood decks. TECHNICAL INFORMATION
decks in corner and perimeter areas. To Dimension: 70 x 70 mm
be installed over the roof waterproofing TECHNICAL INFORMATION Hole diameter: 4.90 mm
membrane in combination with a soft Dimension: 90 mm Thickness: 1.00 mm
thermal insulation only (not for use with Hole diameter: 7.50 mm Corrosion resistance:
rigid thermal insulation). Sarnafast® Thickness: 1.00 mm 15 cycles according to Kesternich
Row Termination Plate RTL shall not be Corrosion resistance:
installed in seems. 15 cycles according to Kesternich

Sarnafast® DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnabar® Fastening Profiles DESCRIPTION CHARACTERISTICS / ADVANTAGES

STANDARD  DETAILS
Row Termination Plate RT Zinc plated steel washer for the row ́ Better load distribution and reduces Folded profile hot-dip coated steel for ́ Lightweight
termination in the mechanically fastened risk of a failure in the membrane the perimeter fastening. ́ Resistance against common environ-
roof system. ́ Lightweight mental influences
́ Resistance against common environ- USES ́ Easy application in use with recom-
USES mental influences Perimeter fastening system in combina- mended setting tools
Termination of row of intermediate spot ́ Easy application in use with recom- tion with Sarnafast® Fastener SBF-6.0 ́ Recycable
fastening system with four pieces Sar- mended setting tools / Sarnabar® Tube SBT-20 on all decks or
nafast® Fastener SF-4.8 on corrugated ́ Recycable Sarnafast® Fastener SF-4.8 on corru- TECHNICAL INFORMATION
steel and solid wood decks in corner and gated steel and solid wood decks. Length: 2250 / 4500 mm
perimeter areas. To be installed over TECHNICAL INFORMATION Width: 30 mm

SUSTAINABLE  SOLUTIONS
the roof waterproofing membrane in Dimension: 90 mm Height: 7 mm
combination with a soft thermal insula- Hole diameter: 4.90 mm Hole diameter: 6.50 / 10 / 15 mm
tion only (not for use with rigid thermal Thickness: 1.00 mm Thickness: 1.50 mm
insulation). Sarnafast® Row Termination Corrosion resistance: Corrosion resistance:
Plate RT shall not be installed in seems. 15 cycles according to Kesternich 15 cycles according to Kesternich

68 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 69


Sarnafil® T ACCESSORIES

FASTENING PRODUCTS

SERVICE  INFORMATION
Sarnabar® Tube SBT-20 DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafast® Fastener SBF-6.0 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Polyamide tube (PA 6) for the perimeter ́ High resistance against mecanical Hardened carbon steel fastener. ́ Resistance against common environ-
fastening. inputs mental influences
́ Lightweight USES ́ Easy application in use qith recom-
USES ́ Resistance against common environ- Fastener in combination with Sarna- mended setting tools
Tube perimeter fastening system in mental influences fast® Washer KTL, IF/G-C Sarnafast® ́ Self drilling fastener, no pre-drilling for
combination with Sarnabar® Fastening ́ Easy application in use with recom- Tube SFT-50, Sarnafast® Row Termina- steel and plywood / OSB applications
Profile 6/15 and Sarnafast® Fastener mended setting tools tion Plate RTL-90, Sarnafast® Insula- ́ Chrome VI-free
SBF-6.0 on all decks. ́ Recycable tion Washer DTL, Sarnabar® Fastening ́ Recycable
Profiles and Sarnabar® Tube SBT-20 into
TECHNICAL INFORMATION steel, concrete and plywood / OSB decks. TECHNICAL INFORMATION

PRODUCT  INFORMATION
Diameter: 20 mm (at collar) Diameter: 6.00 mm
Hole diameter: 12.40 mm Head diameter: 9.80 mm
Available lengths: 40 – 300 mm Available lengths: 35 – 300 mm
Corrosion resistance: Drive:
30 h conditioned in conditioning cell Drive Torx T25
Corrosion resistance:
15 cycles according to Kesternich

Sarnabar® Connection Clip DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafast® Fastener SF-4.8 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Polyamide clip (PA 6). ́ Wasy and fast connection of the Hardened carbon steel fastener. ́ Tread-fast solution

APPLICATION  INSTRUCTIONS
Sarnabar® Fastening Profiles ́ Lightweight
USES ́ 3 in 1 product (connection, protection USES ́ Resistance against common eviron-
Connecting of standard Sarnabar® and spacer) Fastener in combination with Sarnafast® mental influences
Fastening Profiles. ́ Easy application due to click function Washer KT, IF/G-C, Sarnafast® Row Ter- ́ Easy application in use with recom-
́ Makes use of a butt strap obsolete mination Plate RT-90, Sarnafast® Insula- mended setting tools
tion Washer DT and Sarnabar® Fastening ́ Self-drilling fastener, no pre-drilling
TECHNICAL INFORMATION Profiles into steel and plywood / OSB for steel application
Width: 34.50 mm decks. ́ Chrome VI-free
Length: 80 mm ́ Recycable
Height: 11 mm
TECHNICAL INFORMATION
Diameter: 4.80 mm
Head diameter: 8.00 mm
Available lengths: 60 – 300 mm
80 – 300 mm
(magazine loaded)

STANDARD  DETAILS
Drive:
Hexagon head srew 8.00 mm
Corrosion resistance:
15 cycles according to Kesternich

Sarnafil® T Welding Cord DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnafast® Fastener SF-M 4.8
Cord made of FPO compound by extrud- ́ Hot air weldable Also available in magazine loaded ver-
ing procedure. ́ Recyclable sion Sarnafast Fastener SF-M 4.8 with
automated setting tool.

SUSTAINABLE  SOLUTIONS
USES TECHNICAL INFORMATION
In combination with Sarnabar® Fastening Diameter: 4.00 mm
Profiles preventing the membranes from Length: 100 mm
slipping.

70 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 71


Sarnafil® T ACCESSORIES

FASTENING PRODUCTS – TOOLS

SERVICE  INFORMATION
SETTING- AND INSTALLATION TOOLS FOR FASTENING PRODUCTS DRILL BITS FOR FASTENING PRODUCTS

Product Uses Product Uses

For the automated setting of magazine loaded SDS-4,8


Sarnafast® Fastener SF-M 4.8
SDS-5,0
SDS drill bits – available in different lengths
SDS-5,2

SDS-6,3
Automated setting tool for the fast and economic

PRODUCT  INFORMATION
installation of fasteners and washers.
IF240-B For belted fasteners Sarnafast® Fastener SF-M 4.8 For the use in combination with Sarnabar® Tube
with washers Sarnafast® Washer IF/IG-C, KT and SBT-20 and Sarnafast® Tube SFT-50 on concrete
Sarnafast® Insulation Washer DT.
ZVK-4,8 � 100 � 160

ZVK-5,0 � 55 � 115 Conus drill bits for combination


ZVK-5,0 � 100 � 160
with ZAK drill extension
BITS AND ACCESSORIES FOR FASTENING PRODUCTS For the installation of Sarnafast® Fastener SBF-6.0
inside Sarnabar® Tube SBT-20 or Sarnafast® Tube ZVK-5,2 � 100 � 160
SFT-50

APPLICATION  INSTRUCTIONS
ZVK-4,8 � 100 � 165-STOP

T25-32-M6 Insert bit with T25 drive ZVK-5,0 � 25 � 90-STOP

ZVK-5,0 � 35 � 100-STOP
ZA1/4"-M6-300
Drive bar for installation of fasteners and tubes,
ZVK-5,0 � 45 � 110-STOP
length 300 and 750 mm
ZA1/4"-M6-750 Conus drill bits with stop function for combination
ZVK-5,0 � 55 � 120-STOP
with ZAK drill extension
ZVK-5,2 � 25 � 90-STOP
ZA1/4"-M6-EXT100 Drive bar extension, length 100 mm
ZVK-5,2 � 35 � 100-STOP
Adapter to hold Sarnabar® Tube SBT-20 and
ZH-12-RING
Sarnafast Tube SFT-50 onto drive bar ZVK-5,2 � 45 � 110-STOP

ZVK-5,2 � 100 � 165-STOP
For the manual installation of

STANDARD  DETAILS
Sarnafast® Fastener SF-4.8 with HEX 8 head ZAK-500
Drill extension for ZVK conus drill bits,
Socket for fastener with HEX 8 head, for manual ZAK-750
E380-3/8"-34 length 500, 750 and 1000 mm
fastener installation
ZAK-1000
ZA1/4" Drive bar for socket, for manual fastener installation
For the use in combination with Sarnabar® Tube
SBT-20 and Sarnabar® Fastening Profiles, 15 mm hole
For the manual installation of
Sarnafast® Fastener SBF-6.0 Drill extension for ZVK-14 conus drill bits with 14 mm
ZAK-14-500
outer diameter, length 500 mm

SUSTAINABLE  SOLUTIONS
T25-25-HEX1/4" Insert bit with T25 drive and HEX shaft
Conus drill bit for combination with ZAK-14 drill exten-
ZVK-14-5,0 � 100 � 135
sion, with 14 mm outer diameter
Bit holder ZA1/4" Bit holder for bits with HEX shaft
Conus drill bit with stop function for combination with
ZVK-14-5,0 � 45 � 80-STOP
ZAK-14 drill extension with 14 mm outer diameter

72 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 73


Sarnafil® T ACCESSORIES

ROOF DESIGN

SERVICE  INFORMATION
Sarnafil® T Decor Profile DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® T Decor Profile is an FPO ́ Applicable for exposed roofing
extruded profile made which is welded ́ Ease of application
to Sarnafil® T (FPO) sheet waterproofing ́ Suitable for any roof slope
membranes to replicate standing seam ́ Hot air weldable
metal roofing systems.
APPEARANCE / COLOR
USES Surface:
Sarnafil® T Decor Profile may only be ́ Smooth
used by experienced professionals: Color:
́ Creating an appearance of a standing ́ Window grey (RAL 7040)

PRODUCT  INFORMATION
seam metal roof ́ Anthracite (RAL 7016)
́ Other colors on request

TECHNICAL INFORMATION
Length: 3000 mm
Width: 35 mm
Height: 25 mm

Sikagard®-950 DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikagard®-950 is a 2-part, water-based, ́ Good opacity

APPLICATION  INSTRUCTIONS
UV resistant, colored polyurethane-coat- ́ Resistant to UV exposure
ing for Sarnafil® FPO roof waterproofing ́ High flexibility
membranes. ́ Available in many colors
́ Good mechanical properties
USES ́ PVC plasticiser blocking properties
Sikagard®-950 may only be used by ́ Easily cleanable
experienced professionals: ́ Low surface soiling
́ Decorative coating for Sarnafil® FPO ́ Easy application by brush, roller or
roof waterproofing membranes for: airless spray
́ Flat and sloping fully exposed roof
structures
́ New roofs
́ Roof refurbishment
́ Roof graphics
́ Architectural detailing
́ Marking out safety zones

STANDARD  DETAILS
Sikalastic® Primer FPO DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sikalastic® Primer FPO is an one-com- ́ One-component – easy and ready to
ponent, transparent, slightly yellowing, use
solvent-based synthetic polymer primer, ́ Enhance adhesion to Sarnafil® FPO
specifically formulated to bond Sika- Membranes
gard®-950 onto FPO membranes. ́ Fast curing-overcoating possible after
max 1 hour
USES

SUSTAINABLE  SOLUTIONS
Sikalastic® Primer FPO may only be used
by experienced professionals.

74 ROOFING HANDBOOK Sarnafil® T


Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

PRODUCT OVERVIEW LEVELLING- AND


FELTS AND GLASS FLEECE PROTECTION LAYERS

SERVICE  INFORMATION
S-Felt Sikaplan® W S-Felt S-Felt S-Glass S-Felt S-Felt
S-Felt A-300 DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Felt A-300 is a levelling- and protec- ́ Bitumen resistant
A-300 Felt 500 PP S-800 T-300 Fleece-120 VS-140 GK-400
tion layer made of polypropylene (PP). ́ Easily applied
Function Levelling- and Levelling- and Levelling- and Separation-, Separation- Filter Layer Protection- and
Protection Protection Protection Levelling- and and Fire Slip Layer USES APPEARANCE / COLOR
Layer Layer Layer Protection Layer Protection Layer Levelling layer between Sarnafil® T Surface:
membranes and rough surfaces. ́ Structured
Properties
Color:
Base material Polypropylene Polypropylene Polypropylene Polyester Glass fibre Polypropylene Polypropylene ́ Multi-colored
(PP) (PP) (PP) (PES) (PP) with PE film Weight:
(PP / PE ́ 300 g/m²

PRODUCT  INFORMATION
Weight (g/m²) 300 500 800 300 120 140 400

Roll size (m) 2 × 50 2 × 25 2 × 25 2 × 50 2 × 100 2 × 50 2 × 50 Sikaplan® W Felt 500 PP DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sikaplan® W Felt 500 PP is a levelling- ́ Bitumen resistant
Resistance
and protection layer made of polypropyl- ́ Easily applied
UV irradiation ene non woven fabric.
APPEARANCE / COLOR
Bitumen USES Surface:
Alkaline solu- Levelling layer between Sarnafil® T ́ Structured
tions (ph 12) membranes and rough surfaces. Color:
́ Multi-colored

APPLICATION  INSTRUCTIONS
Heat (+60 °C) Weight:
Practical Application ́ 500 g/m²

Bitumen
new or aged S-Felt S-800 DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Felt S-800 is a levelling- and protec- ́ Bitumen resistant
PVC aged
tion layer made of polypropylene (PP). ́ Easily applied
Concrete
USES APPEARANCE / COLOR
Inverted Roof System with XPS Levelling layer between Sarnafil® T Surface:
Filter Layer membranes and rough surfaces. ́ Structured
Color:
Protection- ́ Multi-colored
and Slip Layer Weight:
́ 800 g/m²
Most suitable

STANDARD  DETAILS
Suitable
Conditionally suitable

SUSTAINABLE  SOLUTIONS
76 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 77
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

SEPARATION-,LEVELLING- SEPARATION- AND FIRE


AND PROTECTION LAYER PROTECTION LAYER

SERVICE  INFORMATION
S-Felt T-300 DESCRIPTION CHARACTERISTICS / ADVANTAGES S-Glass Fleece-120 DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Felt T-300 is a separation-, levelling- ́ Bitumen resistant S-Glass Fleece-120 is a glass fibre sepa- ́ Easily applied
and protection layer made of polyester ́ Non decaying ration- and fire protection layer.
(PES). ́ Suitable for mechanical fastening (drill APPEARANCE / COLOR
proved) USES Surface:
USES ́ Recyclable Separation and fire protection layer ́ Structured
S-Felt T-300 is used as a separation between Sarnafil® T membranes and Color:
and levelling layer between Sarnafil® T APPEARANCE / COLOR EPS / XPS insulation. ́ White
membranes and incompatible sub- Surface:
strates. S-Felt T-300 can also be used as ́ Structured
a protection layer between Sarnafil® T Color:

PRODUCT  INFORMATION
membranes and any protective topping ́ White
or pavement.

APPLICATION  INSTRUCTIONS
STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
78 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 79
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

FILTER LAYER PROTECTION- AND SLIP LAYER

SERVICE  INFORMATION
S-Felt VS-140 DESCRIPTION CHARACTERISTICS / ADVANTAGES S-Felt GK-400 DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Felt VS-140 is a filter layer made of ́ Bitumen resistant S-Felt GK-400 is a protection and slip ́ Bitumen resistant
polypropylene (PP) ́ Alkali resistant (pH 11,6) layer made of polypropylene (PP) with a ́ Acids resistant (pH 2,4)
́ Ease of application polyethylene (PE) coating on one side. ́ Easily applied
USES
Filter layer in inverted roofs systems to APPEARANCE / COLOR USES APPEARANCE / COLOR
prevent small particles from penetrating Surface: Protection and slip layer beneath paving Surface:
gaps and voids in the thermal insulation ́ Structured or poured cementitious toppings. ́ Structured and smooth
layer. Color: Color:
́ Grey ́ Multi-colored/black

PRODUCT  INFORMATION
APPLICATION  INSTRUCTIONS
STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
80 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 81
Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

PROTECTION LAYERS PROTECTION-, DRAINAGE-


AND FILTER LAYERS

SERVICE  INFORMATION
Sarnafil® TG 63 DESCRIPTION CHARACTERISTICS / ADVANTAGES Aquadrain 550 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® TG 63 is a protection sheet ́ Hot air weldable Aquadrain 550 is made of mechanically ́ 3 in 1 product (drainage, water reten-
based on flexible polyolefins (FPO) with a ́ Good mechanical strength strengthened Polypropylene (PP) fibres. tion and protection)
glass non-woven flame retardant inlay. ́ Suitable for extensive and intensive
APPEARANCE / COLOR USES green roofs with slopes of minimum
USES Surface: Aquadrain 550 is used as drainage, water 1.5%
Protection layer on top of Sarnafil® T ́ Smooth retention and protection layer for exten- ́ Ease of application
roof waterproofing membranes for bal- Top surface: sive and intensive green roof systems ́ Non decaying
lasted flat roof systems. ́ Greenish with a minimal slope of 1.5%. ́ Not UV stable
́ Anthracite
Bottom surface: APPEARANCE / COLOR

PRODUCT  INFORMATION
́ Dark grey Surface:
́ Structured
TECHNICAL INFORMATION Color:
Length: 25.00 / 15.00 / 10.00 m ́ Brown
Width: 2.00 m
Thickness: 1.30 / 2.00 / 2.50 mm

Sarnafil® TG 37-12 DESCRIPTION CHARACTERISTICS / ADVANTAGES SikaRoof® Drainage Layer 20L2F DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® TG 37-12 is a protection sheet ́ Hot air weldable SikaRoof® Drainage Layer 20L2F com- ́ 3 in 1 product (drainage, protection and
based on flexible polyolefins (FPO) with a ́ Good mechanical strength prises of a threedimensional composite filter layer)

APPLICATION  INSTRUCTIONS
glass non-woven flame retardant inlay. polymer drainage core connected to a
APPEARANCE / COLOR fleece filter (PP) on both sides. APPEARANCE / COLOR
USES Surface: Color:
Protection layer on top of bituminous ́ Smooth USES Drainage core
roof waterproofing membranes for bal- Color: SikaRoof® Drainage Layer 20L2F may ́ Black
lasted flat roof systems. Top surface: only be used by experienced profession- Filter fleece
́ Brown als: ́ Light grey
Bottom surface: ́ It is used as a drainage, filter and pro-
́ Dark grey tection layer for flat roof extensive and
intensive green roof systems
TECHNICAL INFORMATION
Length: 20.00 m
Width: 2.00 m
Thickness: 1.20 mm

STANDARD  DETAILS
S-Protection Sheet RS DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Protection Sheet RS is made of ́ Easy to install
technical-grade recycled rubber granu- ́ High compressive strength
late, polyurethane-bonded. ́ Extremly rugged and durable
́ Rot-resistant
USES ́ Recyclable
S-Protection Sheet RS is a versatile pro-
tection layer on flat roofs and building APPEARANCE / COLOR
structures. Surface:
́ Grain-textured

SUSTAINABLE  SOLUTIONS
Top surface:
́ Black with multicolored speckles

TECHNICAL INFORMATION
Length: 10.00 / 8.00 m
Width: 1.25 m
Thickness: 6.00 / 8.00 mm

82 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 83


Sarnafil® T ACCESSORIES

SYSTEM OVERVIEW
SikaRoof® CONTROL SYSTEMS

SERVICE  INFORMATION
Sarnafil® T CONTROL PIPE SET WITH WATERSTOP SYSTEM – COMPARTMENTS

Sarnafil® T Control Pipe Set

PRODUCT  INFORMATION
2

APPLICATION  INSTRUCTIONS
900_020945_N0153C_2010_en

1 Vapour control layer 4 Sarnafil® T membrane


2 Sarnafil® T Control Pipe 5 Prefabricated Sarnafil® T flashing
3 Thermal insulation 6 Cap with integrated insulation plug

SikaRoof® Control Systems enables to inspect water ingress and detect / locate the defective area and roof build-up during the Waterstop System – Compartments The roof area shall be divided into compartments of 100 m² up to 600 m² in order to
entire construction as well as service life of roof waterproofing system. limit the leaking area when the roofing ever becomes demaged. The compartment is
SikaRoof® Control Systems therefore help to secure material assets and prevent consequential damages. executed with the waterstops system.
The system is designed as modular system with the following possible expansion stages:
Compartment size:
Sarnafil® T CONTROL PIPE SET WITH WATERSTOP SYSTEM – COMPARTMENTS ́ 100 to 300 m² if the protective layer is difficult to remove
Enables to check any water ingress by checking the control pipe visually on the roof. ́ 300 to 600 m² if the protective layer is easy to remove

Sarnafil® T CONTROL PIPE SET WITH WATERSTOP SYSTEM – COMPARTMENTS AND LEAK DETECTION SYSTEM The design and layout of the compartment systems should be co-ordinated with roof

STANDARD  DETAILS
Enables to check any water ingress by checking the control pipe visually on the roof. If any water ingress is visible, the defect can valleys and the drainage system. Waterstops are typically positioned at high points
be located very precisely. A control pipe located in every compartment. and the control pipe at low point of the roof. Each compartment needs to be provided
with a control pipe.
Sarnafil® T CONTROL PIPE SET WITH LEAK DETECTION SYSTEM
Enables to check any water ingress by checking the control pipe visually on the roof. If any water ingress is visible, the defect can Waterstops form a watertight seal between the membrane and the vapour control
be located very precisely. Control pipes to be best set out in opposite corners. layer in order to minimize water damage in case of a leak.

SUSTAINABLE  SOLUTIONS
84 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 85
Sarnafil® T ACCESSORIES

SYSTEM OVERVIEW
SikaRoof® CONTROL SYSTEMS

SERVICE  INFORMATION
900_020910_N0051O_1909_en
Waterstop System – Compartments Sarnafil® T CONTROL PIPE SET WITH WATERSTOP SYSTEM – COMPARTMENTS AND LEAK DETECTION SYSTEM
6
Sarnafil® T Control Pipe Set
5 and Leak Detection System

4 8
3 7

5
2

PRODUCT  INFORMATION
4

3
1
1

1 Roof deck 4 Sarnafil® T membrane adhered with hot


2 Bituminous vapour control layer, fully bitumen to the vapour control layer
900_020945_N0154C_2011_en
adhered at least in the area of partition 5 Loose laid thermal insulation layer –

APPLICATION  INSTRUCTIONS
3 Thermal insulation layer – edge cut at edge cut a 45°
45° – adhered to serve as a stopper for the 6 Sarnafil® T membrane welded to the 1 Vapour control layer 5 SikaRoof® Control Contact Plate
partition already installed membrane 2 Sarnafil® T Control Pipe 6 Sarnafil® T membrane
3 Thermal insulation 7 Prefabricated Sarnafil® T flashing
4 Sika® RCS Glass Fleece 8 Cap with integrated insulation plug
or Stainless Steel Mesh

The SikaRoof® Control Glass Fleece or Stainless Steel Mesh (electrical conductive)
is applied below the roofing membrane on top of the thermal insulation.

900_020910_N0117C_1910_en

STANDARD  DETAILS
1
3
2

5 4

SUSTAINABLE  SOLUTIONS
900_020910_N0119C_1910_en

1 Compartment 4 Control pipe


2 Waterstop 5 Roof drain
3 Valley

86 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 87


Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

SYSTEM OVERVIEW SikaRoof® CONTROL SYSTEMS


SikaRoof® CONTROL SYSTEMS

SERVICE  INFORMATION
Sarnafil® T CONTROL PIPE SET WITH LEAK DETECTION SYSTEM Sarnafil® T Control Pipe Set DESCRIPTION CHARACTERISTICS / ADVANTAGES
The Sarnafil® T Control Pipe Set is made ́ Resistant to UV exposure
The SikaRoof® Control Glass fleece (electrical conductive) is applied below the roofing of rigid high quality polypropylene (PP) ́ Ease of application
membrane on top of the thermal insulation. pipe and cap, expanded polyethylene
(EPE) insulation plug and prefabricated PACKAGING
The control pipes (2 pieces) with contact plate are best set out in opposite corners Sarnafil® T (FPO) flashing. The Sarnafil® T Control Pipe Set
set back from all perimeter details, rooflight and ventilator upstands, roof drains, soil consists of:
pipe vents or any other penetration or upstand detail of the roof area. There should USES ́ Pipe with base plate (one piece)
be ample space to access them safely. With larger individual roofs over 1500 m² ad- The Sarnafil® T Control Pipe Set enables ́ Cap with integrated insulation plug
ditional control pipes with contact plate will be required. to check the watertightness of a flatroof ́ Prefabricated Sarnafil® T flashing
from the rooftop.

PRODUCT  INFORMATION
LEAK DETECTION

Low voltage leak detection SikaRoof® Control glass fleece is


required below the roofing membrane.
When the leak detection is conducted,
the roof surface (roof membrane) needs Sika® RCS Glass Fleece DESCRIPTION CHARACTERISTICS / ADVANTAGES
to be wet. Sika® RCS Glass Fleece is a conductive ́ Easily applied
Additional technical build-up made of and fire protection layer made of non- ́ Suitable for mechanically and bal-
conductive material like metal (ventila- woven glass fibre. lasted roof systems
tion units, photovoltaics, etc.) must be

APPLICATION  INSTRUCTIONS
electrically isolated / separated from the USES
roofing membrane. Sika® RCS Glass Fleece may only be used
Ballasted systems (gravel or green roofs) by experienced professionals.
build-up must be continuously electri- ́ Sika® RCS Glass Fleece is used as
cally conductive. No drainage layer made a conductive layer to facilitate leak
of HDPE shall be applied. detection below Sarnafil® T roofing
membranes.

Sika® RCS Stainless Steel Mesh DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sika® RCS Stainless Steel Mesh is an ́ Highly electrically conductive
electrically conductive stainless steel ́ Easily applied
mesh. ́ Corrosion resistant
High voltage leak detection SikaRoof® Control glass fleece is ́ Not flammable
required below the roofing membrane. USES ́ Suitable for adhered roof systems
When the leak detection is conducted, Sika® RCS Stainless Steel Mesh may only

STANDARD  DETAILS
the roof surface (roof membrane) needs be used by experienced professionals.
to be dry. ́ Sika® RCS Stainless Steel Mesh is
used as a conductive layer to facilitate
leak detection below adhered
Sarnafil® T roofing membranes.

SikaRoof® Control Contact Plate DESCRIPTION CHARACTERISTICS / ADVANTAGES


The SikaRoof® Control Contact Plate is ́ Easy application without the use of
a stainless steel plate to connect the fasteners

SUSTAINABLE  SOLUTIONS
applied conductive glass felt wth the ́ Plate includes the the 800 mm long
read-out device. connection wire

USES
SikaRoof® Control Contact Plate may
only be used by experienced profession-
als.
́ Contact plate between the applied
conductive glass felt and the read-out
device.

88 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 89


Sarnafil® T ACCESSORIES

TECHNOLOGY OVERVIEW
THERMAL INSULATIONS

SERVICE  INFORMATION
INTRODUCTION PRODUCT TECHNOLOGIE – MAIN TECHNOLOGIES
Thermal insulation is one of the key construction elements, creating comfortable environment inside the building by protecting it
from the heat and the cold. PIR / PUR EPS

The importance of thermal insulation has increased recently a lot due to continuously changing insulation standards worldwide,
which put higher and higher demands to thermal resistance of building structures to reduce energy losses for heating or cooling.
The main coefficient used for evaluation of such thermal characteristics is U-Value, which r­ epresents the energy transmission
(loss) per 1 m² K of the building structure.

Insulation types used in flat roofing systems should have not only high thermal characteristics but sufficient mechanical proper-
ties as well to be able to withstand loads, which occur in v­ arious roof systems (like snow loads, limited pedestrian traffic for

PRODUCT  INFORMATION
maintenance reasons, ballast, ­moisture in inverted roof build up, etc.) and to match specific fire requirements.

This section presents most common insulation types for this application and their suitability to Sika flat roof waterproofing sys-
tems. Properties of specific insulation products on the market may vary from listed general characteristics. PIR / PUR is a rigid polyisocianurate foam produced in a chemi- EPS (Expanded Polystyrene) is a plastic styrol foam made in
cal process ­(exothermic chemical reaction) made by mixing physical p
­ rocess when polystyrene granules are expanded with
Product portfolio of Sika incorporates some of these insulation product types. For specific p
­ roduct information please refer to MDI, polyols, blowing agents (usually pentan gas) and other ad- vapour and then pressed together at high temp to form blocks.
respective product brochures and data sheets. ditives. The products are known for one of the lowest thermal This is one of the most cost efficient insulants, which gained
conductivities. through that popularity on various local markets. In some
Majority of PIR/PUR boards for flat roofing applications have countries it has a limited use on exposed roofs due to fire
facers. It can be aluminium or glass tissue or paper. Facers regulations, but majority of standard ballasted applications are
prevent outgassing effect. done with this insulant.

APPLICATION  INSTRUCTIONS
CHARACTERISTICS / ADVANTAGES CHARACTERISTICS / ADVANTAGES
́ Excellent thermal characteristics ́ Cost efficient
́ Low weight ́ Low weight
́ Ideal for adhered applications ́ Ideal for gravel ballasted applications
́ High compression strength ́ High compression strength

Mineralwool XPS

STANDARD  DETAILS
Mineral (stone) wool is a traditional building insulant known for XPS (Extruded Polystyrene) is a plastic styrol foam produced
it’s ­incombustible properties. with e­ xtrusion process. The polystyrene granules are mixed
The mineralwool products are generally produced out of basalt with the b ­ lowing agent (CO or Freon) and then extruded.
²
in an physical process – basalt is heated up to 1500 °C till it XPS has very high compression strength and very low water
gets into liquid state, then fibres are formatted with air pres- ­absorption and these unique advantages determine it‘s most

SUSTAINABLE  SOLUTIONS
sure and organic binders are added to better hold these fibers common applications – utility decks with high loads and in-
together. verted roofs (when thermal insulation is placed above water-
Mineralwool products for standard flat roofing applications are proofing layer).
single or dual density rigid boards with mechanical and com-
pression strength roperties sufficient for intended application. CHARACTERISTICS / ADVANTAGES
́ Very high compression strength
CHARACTERISTICS / ADVANTAGES ́ No or very low water absorption
́ Non combustible ́ Low weight
́ Excellent acoustical properties ́ Ideal for inverted applications and utility decks with high
́ Dimensionally stable loads (car traffic)

90 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 91


Sarnafil® T ACCESSORIES

TECHNOLOGY OVERVIEW
THERMAL INSULATIONS

SERVICE  INFORMATION
PRODUCT TECHNOLOGIE – SPECIALITIES PRODUCT TECHNOLOGIE – COMBINATIONS

Coverboard High Density Board EPS combined with Mineralwool

Numerous combinations of several insulation types can be


Installed together in a single roof build-up to reach:
́ Desired thermal values
́ Higher compression strengths
́ Extended fire characteristics
́ Economical properties, etc.

PRODUCT  INFORMATION
CHARACTERISTICS / ADVANTAGES
́ Combining strengths of various insulation types
́ Improving acoustics
Coverboards for roofing applications are usually non-structural, The high density board is a flat roof overlay board for use in As an example EPS can be combined with Mineralwool, which ́ Customized thermal insulation build up to special customer
­glass-mat faced, moisture-resistant, treated gypsum or combination with PIR / PUR boards. It provides added protec- can on one hand improve fire characteristics (compared to needs in case desired technical values or cost efficiency can
cementitious core panels. This treated gypsum or cementitious tion to the insulation below in areas of excessive traffic and pure EPS build-up), provide higher compression strength and not be reached with one product group
core is an integral part of the inorganic glass mat surfacing high loadings. one other hand bring some additional cost efficiency.
on both sides. Such boards are installed to create rigid roofing In addition to its compressive performance, high density board
surface and to bring ­additional thermal resistance to the roof- exhibits excellent dimensional stability, ideal in flat roofs
ing structure as well. which experience intense thermal cycling between cold winter
temperatures and extremely hot summers. U-VALUES FOR ROOF BUILD-UP ON STEEL DECK (W/m²·K)

APPLICATION  INSTRUCTIONS
CHARACTERISTICS / ADVANTAGES ́ Sarnafil® TS 77 roof waterproofing membrane
́ Very high compression strength CHARACTERISTICS / ADVANTAGES ́ Thermal insulation
́ Excellent fire ratings ́ High compressive strength ́ Sarnavap® vapour control layer
́ Excellent dimensional stability ́ Steel deck 1.00 mm

Cellular Glass

STANDARD  DETAILS
80 mm 100 mm 120 mm 140 mm 160 mm 180 mm 200 mm 220 mm 240 mm 260 mm

PIR / PUR
0.28 0.22 0.19 0.16 0.14 0.13 0.11 0.10 0.09 0.09
Aluminium 0.023 W/(m·K)

PIR / PUR
Cellular glass is manufactured primarily from sand, limestone, 0.33 0.27 0.23 0.19 0.17 0.15 0.14 0.12 0.11 0.11
Glass Tissue 0.028 W/(m·K)
and soda ash. (recycled glass could also be used). These
ingredients are melted into molten glass, which is cooled and EPS
0.34 0.28 0.23 0.20 0.18 0.16 0.14 0.13 0.12 0.11
crushed into a fine powder. The powdered glass is poured into Graphite 0.029 W/(m·K)

SUSTAINABLE  SOLUTIONS
molds and heated that causes the particles to adhere to one EPS
0.43 0.35 0.29 0.25 0.22 0.20 0.18 0.16 0.15 0.14
another. Next, a small amount of finely ground carbon-black Standard 0.037 W/(m·K)
is added, and the material is heated in a “cellulation” process.
XPS
Here, the carbon reacts with oxygen, creating carbon dioxide, 0.34 0.28 0.23 0.20 0.18 0.16 0.14 0.13 0.12 0.11
HCFC Blown 0.029 W/(m·K)
which forms the insulating bubbles in the foamglas.
XPS
0.43 0.35 0.29 0.25 0.22 0.20 0.18 0.16 0.15 0.14
CHARACTERISTICS / ADVANTAGES CO² Blown 0.037 W/(m·K)
́ No water absorption
Mineral Wool
́ High resistance to fire, non combustible 0.47 0.38 0.32 0.27 0.24 0.22 0.19 0.18 0.16 0.15
0.040 W/(m·K)
́ High compression strength

92 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 93


Sarnafil® T ACCESSORIES

TECHNOLOGY OVERVIEW
THERMAL INSULATIONS

SERVICE  INFORMATION
COMPATIBILITY OF MAIN THERMAL INSULATION TYPES TO SIKA ROOFING SYSTEMS MAIN VALUES THERMAL INSULATION
Material Mechanically Adhered Gravel ballasted Green and Utility Inverted Metal roof PIR / PUR Mineralwool EPS XPS
types fastened refurbishment
Aluminium faced boards ld 0.038 – 0.040 W/(m·K) EPS with graphite Standard boards, HCFC
Compatible Compatible Compatible Limited Not compatible Compatible ld 0.022 – 0.025 W/(m·K) ld 0.029 – 0.031 W/(m·K) blown
compatibility ld 0.029 – 0.034 W/(m·K)
Thermal conductivity
Glass tissue, paper Due to higher Additional flute
PIR / PUR Glass tissue faced boards Standard EPS CO² blown XPS boards
or aluminium faced compression loads filler may be
ld 0.024 – 0.030 W/(m·K) ld 0.034 – 0.038 W/(m·K) ld 0.035 – 0.037 W/(m·K)
boards shall be affecting thermal required depend-
used. insulation. ing on the metal 100 – 150 kPa 40 – 60 kPa 100 – 250 kPa 200 – 700 kPa

PRODUCT  INFORMATION
profile.
It is sufficient for flat It is sufficient for flat ex- It is sufficient for flat It is sufficient for utility
Compatible Compatible Limited Very limited Not compatible Compatible Compression strenght exposed applications and posed applications with- exposed applications and decks with car traffic.
compatibility compatibility ballasted ­applications out heavy pedestrian load. most of b ­ allasted applica-
without heavy loads. tions.
Only special min- Due to higher Due to higher Additional flute
eralwool boards compression loads compression loads filler may be Boards have high resis- Boards have limited resis- Boards have high resis- Zero water absorption, can
Mineralwool with facings shall on thermal insula- on thermal insula- required depend- Resistance to water tance to moisture absorb- tance to moisture absorb- tance to moisture absorb- be used in inverted roofing
be used in order to tion. Every project tion. Every project ing on the metal absorption tion, but they still can not tion. tion, but they still can not ­applications.
provide good bond needs an evalu- needs an evalu- profile. be used in inverted roofs. be used in inverted roofs.
without extreme ation. ation.
30 to 40 kg/m³ 110 to 200 kg/m³ 20 to 30 kg/m³ 25 to 40 kg/m³
adhesive consump-

APPLICATION  INSTRUCTIONS
tion. Most common density of
Weight the boards for flat roofing
Compatible Compatible Compatible Limited Not compatible Compatible
applications is around
compatibility
150 kg/m³.
A separation layer Adhesive type shall Due to higher Additional flute
Dimensional stability / Up to 1 % in average 0% up to 2% in average up to 2% in average
shall be ­applied in be observed. Felt- compression loads filler may be
average shrinking rates
case of special fire back membranes affecting thermal required depend-
EPS requirements. can be adhered to insulation. Every ing on the metal Available Available Available Available
EPS with Sarna- project needs an profile.
Can be either cut out of Can be either cut on site or Is usually cut out of in- Harder to cut than ex-
col®-2142 or Sar- evaluation. A separation layer Availability of the block in production or in production process. Cut- sulation block by heated panded polystyrene
nafil® TG 76 FSA. shall be applied in tapered Insulation can also be produced as a ting mineral wool on site wire in production or on boards. Usually prefabri-
case of special fire
ready board with a pitch. releases fibers which may the site. cated in production.
requirements.
irritate.
Compatible Compatible Compatible Compatible Compatible Compatible

A separation layer Adhesive type shall Additional flute

STANDARD  DETAILS
shall be ­applied in be observed. Felt- filler may be
case of special fire back ­membranes required depend-
XPS requirements. can be adhered to ing on the metal
XPS with Sarna- profile.
col®-2142 or Sar- A separation layer
nafil® TG 76 FSA. shall be applied in
case of special fire
requirements.

Coverboard Compatible Compatible Compatible Compatible Compatible Compatible

SUSTAINABLE  SOLUTIONS
Note: Every project needs an evaluation.

94 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 95


Sarnafil® T ACCESSORIES

TECHNOLOGY OVERVIEW
THERMAL INSULATIONS

SERVICE  INFORMATION
BEHAVIOUR IN FIRE
EUROPEAN FIRE CLASSIFICATION MATERIALS OF CLASSES A2 TO D ARE TESTED FOR SMOKE EMISSIONS

Product Classification System Classification s1 s2 s3

Smoke development rate ≤ 30 m²/s2 Smoke development rate ≤180 m²/s2 Products which does not fulfil s1 and s2
Reaction to Fire according External Fire Exposure Fire Resistance of Structures according
Total smoke propagation in 600s ≤ 50 m² Total smoke propagation in 600s ≤ 200 m²
to EN 13501-1 according to EN 13501-5 to EN 13501-2
Single product is tested to its behaviour External fire exposure tests behaviour of roofing Fire Resistance test represents how long the MATERIALS OF CLASSES A2 TO D ARE ALSO TESTED FOR BURNING DROPLETS
in fire, smoke production, heat emis- system with various slopes and ­various wind structure can resist fire without loosing ist
d0 d1 d2
sions, etc. speeds to external fire influence (fire in on top of structural abilities, entegrity and insulation char-
the roofing surface). acteristics. Fire is applied from underneath the No droplets within 600 secs Droplets burn for less than 10 secs within Products which does not fulfil d0 and d1

PRODUCT  INFORMATION
roofing structure. 600 secs

PIR / PUR Mineralwool EPS XPS

PRODUCT CLASSIFICATION – REACTION TO FIRE ACCORDING TO EN 13501-1 Class E according to EN 13501-1 Class A1 according to EN 13501-1 Class E according to EN 13501-1 Class E according to EN 13501-1

Class Description Main characteristics Related testing procedures The boards are classified as com- The boards are classified as in- The boards are classified as The boards are classified as
bustible, but they do not spread combustible. combustible, they melt during combustible, they melt during
Non combustible, Increase of temperature ≤ 30°C,
the flame, do not melt in fire and fire, but products are self-extin- fire, but products are self-extin-
Do not contribute to fire growth in any phase of fire and weight loss ≤ 50%, EN ISO 1182 and
A1 are self-extinguishing. The short guishing. The short temperature guishing. The short temperature
­including fully developed fire. and no sustained flaming
temperature resistance is 250 °C resistance is 80 – 90 °C. resistance is 70 – 90 °C.
Combustion heat ≤ 2.0 MJ/kg EN ISO 1716 and long temperature resistance

APPLICATION  INSTRUCTIONS
90 °C.
Gives no significant contribution to fire growth and Increase of temperature ≤ 5 0 °C,
fire load in a fully developed fire. and Weight Loss ≤ 50%, EN ISO 1182 or
and Sustained flaming ≤ 20 s
SYSTEM CLASSIFICATION – EXTERNAL FIRE EXPOSURE EN 13501-5
A2 Combustion Heat ≤ 3.0 MJ/kg EN ISO 1716 and
Four basic tests can be done to evaluate exernal fire behaviour of the roof
Heat release rate ≤ 120 W/s,
lateral flame spread < specimen edges EN 13823 Test 1 Test 2 Test 3 Test 4
Total heat release within 600 s ≤ 7.5 MJ Testing pitch 15 °/ 45 ° 30 ° 5 °/ 30 ° 0 °/ 45 °
Do not lead to flashover situation, however they Heat release rate ≤ 120 W/s, Apply to following roof pitches < 20 °/ ≥ 20 ° All pitches < 10 °/ ≥ 10 ° and < 70 ° < 10 °/ ≥ 10 °
will ­contribute to a fully developed fire. lateral flame spread < specimen edges EN 13823 and
Total heat release within 600 s ≤ 7.5 MJ Fire
B
EN ISO 11925-2 Wind
Spread of flame ≤ 150 mm within 60 sec
Exposure to fire 30 s
Radiant heat
Shows limited fire spread during exposure to fire Heat release rate ≤ 250 W/s,
2 stage test

STANDARD  DETAILS
of single burning item, may lead to flashover situ- lateral flame spread < specimen edges EN 13823 and
C ation, but only in the second part of the reference Total heat release within 600 s ≤ 15 MJ
test, i.e. after more than 10 minutes.
EN ISO 11925-2
Spread of flame ≤ 150 mm within 60 sec
Exposure to fire 30 s

Can withstand small flame for certain time with-


Heat release rate ≤ 750 W/s EN 13823 and
out s­ ignificant fire spread, may lead to flashover
D situation in the first part of the reference test, i.e.
EN ISO 11925-2
within 10 minutes, but not before 2 minutes. Spread of flame ≤ 150 mm within 60 sec
Exposure to fire 30 s

Are able to withstand small fire for a short time

SUSTAINABLE  SOLUTIONS
EN ISO 11925-2
E without significant spread of flame, may lead to Spread of flame ≤ 150 mm within 20 sec
Exposure to fire 15 s
flashover within 2 minutes.

Products which can not be classified under A-E


F No performance determined
classes.

96 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 97


Sarnafil® T ACCESSORIES

THERMAL INSULATIONS

SERVICE  INFORMATION
Sikatherm® PIR GT DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sikatherm® PIR GT is an insulation board ́ Produced with a blowing agent with
for flat Roofing. It is faced on both sides zero Ozone Depletion Potential (ODP)
with a coated glass tissue bonded to the ́ Low thermal conductivity
insulation core and produces a tough, ́ Ideal for new construction and refur-
durable, light weight insulation board. bishment
́ High compressive strength
USES ́ Light weight and low load on the roof-
Thermal insulation underneath ing structure
Sarnafil® T roof waterproofing mem-
branes.

PRODUCT  INFORMATION
Sikatherm® PIR AL DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sikatherm® PIR AL is an insulation ́ Produced with a blowing agent with
board for flat Roofing. It is faced on zero Ozone Depletion Potential (ODP)
both sides with an aluminium composite ́ Ideal for new construction and refur-
foil bonded to the insulation core and bishment
produces a tough, durable, light weight ́ High compressive strength
insulation board. ́ Light weight and low load on the roof-

APPLICATION  INSTRUCTIONS
ing structure
USES
Thermal insulation underneath
Sarnafil® T roof waterproofing mem-
branes.

Sikatherm® EPS DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikatherm® EPS are boards of expanded ́ Homogeneity of the physical and me-
polystyrene with high thermal insulating chanical characteristics of the product
properties, which remain unaffected in and therefore isotopical behaviour
time. ́ Stability against tension, distortion,
break, degradation and ageing.
USES ́ Ideal for new constructions and refur-
Thermal insulation underneath bishment projects

STANDARD  DETAILS
Sarnafil® T roof waterproofing mem- ́ Lightweight, applying thus low load on
branes. the roofing structure
́ 100% recyclable

Sikatherm® XPS DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sikatherm® XPS is a rigid extruded ́ Very low thermal conductivity
polystyrene insulation board with self- ́ Ideal for new constructions and refur-

SUSTAINABLE  SOLUTIONS
extinguishing properties that can be bishment projects
used as part of SikaRoof® waterproofing ́ High compression strength
systems. ́ Lightweight and low load on the roof-
ing structure
USES ́ Withstands freeze / thaw cycles
Thermal insulation underneath and ́ Closed cell structure, which minimizes
above Sarnafil® T roof waterproofing water absorption
membranes.

98 ROOFING HANDBOOK Sarnafil® T


Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

PRODUCT OVERVIEW VAPOUR- VAPOUR CONTROL LAYERS


CONTROL LAYERS / BARRIERS

SERVICE  INFORMATION
BASICS Sarnavap® 1000 E DESCRIPTION CHARACTERISTICS / ADVANTAGES
Moisture in today’s buildings can be a source of continuous problems if not tackled professionally. This applies equally, to both Sarnavap®-1000 E is an unsupported ́ Ease and speed of installation
new and existing buildings, particularly those that house high-tech- electronics, machinery and computer equipment, or which vapour control ́ Stays flexible at low temperatures
have moisture sensitive finishes or contents that need to be protected against condensation and its consequences. layer based on Polyethylen (PE). ́ Non-decaying
́ Constant vapour diffusion resistance
FUNCTION OF A VAPOUR- CONTROL LAYER / BARRIER USES ́ Recyclable
The function of a vapour- control layer / barrier is firstly to avoid moisture build up in the fabric or structure of a building, where it ́ Vapour control layer (VCL) is ap-
could find its way into the insulation and reduce its thermal efficiency, or cause damage to other building elements. In addition to plied over most common substrates. APPEARANCE / COLOR
this, the vapour-control layer / barrier also serves to help secure the air tightness of the building. Substrates should be smooth, dry and Surface:
strong enough to support foot traffic. ́ Smooth, PE-LD foil
́ If the substrate surfaces is rough Color:

PRODUCT  INFORMATION
Sarnavap® Sarnavap® Sarnavap® S-Vap® Sarnavap® Sarnavap® (e.g. raw concrete or sloped top- ́ Light blue
-1000 E -2000 E -3000 M -4000 E SA FR -5000 E SA FR -5000 E SA ping), install a levelling layer beneath
Sarnavap®-1000 E or use foam-backed
FM
Sarnavap® 3000M.
Properties ́ Sarnavap®-1000 E vapour control layer
is used for flat and pitched roofs
Base material Polyethylene Polyethylene Polyethylene Polyethylene / Aluminium / Aluminium /
(PE-LD) (PE-LD / HD) (PE-LD) (PE-Aluminium) Polymer Bitumen Polymer Bitumen

Color Light blue Green Black / White Off White / Grey Aluminium / Aluminium / Sarnavap®-2000 E DESCRIPTION CHARACTERISTICS / ADVANTAGES
Polyethylene foam Aluminium PET film PET film Sarnavap®-2000 E is an unsupported ́ Ease and speed of installation
vapour control layer based on Polyethyl- ́ Stays flexible at low temperatures

APPLICATION  INSTRUCTIONS
Roll size (m) 5 × 25 4 × 25 1.50 × 50 1.20 × 70 1.08 / 1.38 × 40 1.08 × 30 ene (PE). ́ Constant vapour diffusion resistance
Weight (g/m²) 195 230 400 210 400 650
USES APPEARANCE / COLOR
Reaction to fire Class E Class E Class E Class E Class E Class E Vapour control layer for flat roofs. Surface:
Diffusion resistance ́ Smooth, PE-LD/HD foil
> 900’000 > 1’300’000 > 600’000 > 2’500’000 > 3’000’000 > 3’000’000 Color:
factor µ
́ Green
Diffusion equivalent
≥ 200 ≥ 300 ≥ 200 ≥ 1’500 ≥ 1’800 ≥ 1’800
air layer Sd (m)

Moisture vapour
transmission < 0.8 < 0.3 < 1.5 < 0.06 < 0.04 < 0.04
(g/m²/24 h)

Vapour resistance
> 900 > 1’450 > 450 > 7’500 > 9’000 > 9’000
(M Ns/g) Sarnavap®-3000 M DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnavap®-3000 M is an unsupported ́ Ease and speed of installation

STANDARD  DETAILS
Application
vapour control layer based on Polyethyl- ́ Stays flexible at low temperatures
High humidity ene (PE). The rear side is covered with a ́ Non-decaying
polyethylene foam and provided with a ́ Constant vapour diffusion resistance
Moderate humidity
butyl-seam adhesive tape at one longi- ́ Recyclable
Low humidity tudinal edge.
APPEARANCE / COLOR
Vapour control layer USES Surface:
Vapour barrier ́ Vapour control layer (VCL) is ap- ́ Smooth, PE-LD foil
plied over most common substrates. Color:
Accessories Substrates should be dry and strong Top surface:

SUSTAINABLE  SOLUTIONS
enough to support foot traffic. ́ Black
Sarnavap® Tape F
́ Sarnavap®-3000 M vapour control lay- Bottom surface:
Sarnatape® 20 er is used for flat roofs. It’s designed ́ White polyethylene foam
specially for slight roughly roof decks.
Primer-130

Primer-600

Achived / Used with products according to CE Marking EN 13984


Sarnavap 5000 E according to EN 13970

100 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 101


Sarnafil® T ACCESSORIES

VAPOUR BARRIERS

SERVICE  INFORMATION
S-Vap-4000 E SA FR DESCRIPTION CHARACTERISTICS / ADVANTAGES Sarnavap®-5000 E SA DESCRIPTION CHARACTERISTICS / ADVANTAGES
S-Vap-4000 E SA FR is a polyethyl- ́ Ease and speed of installation from Sarnavap®-5000 E SA is a multi-layered, ́ Ease and speed of installation from
ene, self-adhesive, multi-layered, fire self-adhesive properties self-adhesive vapour barrier manufac- self-adhesive properties
reduced, vapour barrier manufactured ́ Long roll lengths reduce T-joints tured from polymer modified bitumen ́ Can be used in a fully adhered roof
from cross laminated PE-film with an ́ Good tear resistance under foot traf- with a glass-fibre matt reinforcement build-up. No additional fasteners
aluminium inlay and a hot melt adhesive fic makes it ideal for use on profiled and an aluminium foil top layer. required for securing the thermal insu-
on the underside. metal decks lation boards to the structural deck
́ Slip resistance due to textured surface USES ́ Temporary waterproof top layer for up
USES Sarnavap®-5000 E SA may only be used to 4 weeks, without the requirement
As a vapour barrier over most common APPEARANCE / COLOR by experienced professionals: for additional weight/ballast and/or
roof deck types in combination with me- Color: ́ As a vapour barrier over most common mechanical fastenings

PRODUCT  INFORMATION
chanically fastened roof assembly: Top surface: roof deck types: ́ High self adhesion strength allows
́ Metal Plywood panels, timber boards, ́ Off white ́ Concrete / cementitious high wind design loads from 2,4 kN/m²
oriented strand board (OSB) Bottom surface: ́ Metal to 2,8 kN/m²
́ Temporary waterproofing layer for up ́ Grey Aluminium with release liner ́ Plywood panels, timber boards, ori- ́ Provides an air tight layer
to 4 weeks. Minimum roof slope of 2 ented strand board (OSB) ́ High tear resistance to foot traffic dur-
% (~1,1°) ́ Temporary waterproofing layer for up ing roof build up activities
to 4 weeks ́ High water vapour resistance makes it
suitable in combination with all types
Sarnavap®-5000 E SA FR DESCRIPTION CHARACTERISTICS / ADVANTAGES of membranes
Sarnavap®-5000 E SA FR is a self-adhe- ́ Ease and speed of installation from ́ Accommodates a wide range of roof
sive, multilayered, fire reduced, vapour self-adhesive properties system, deck types and substrate

APPLICATION  INSTRUCTIONS
barrier manufactured from polymer ́ Temporary waterproof top layer for up combinations
modified bitumen with a glass-fibre to 4 weeks, without the requirement ́ Can be bonded onto flashings, inclined
matt reinforcement and an aluminium for additional weight/ballast nd/or or vertical Surfaces
foil top layer. mechanical fastenings
́ Good adhesion/bonding strength lead- APPEARANCE / COLOR
USES ing to an air tight roof construction Surface:
Sarnavap®-5000 E SA FR may only be ́ Good tear resistance to foot traffic ́ Aluminium foil with PET film
used by experienced professionals: during roof build up activities
́ As a vapour barrier over metal decks ́ High water vapour resistance makes it
in combination with mechanically suitable in
fastened roof assembly. ́ combination with all types of mem-
́ Temporary waterproofing layer for up branes
to 4 weeks ́ Can be bonded onto inclined or vertical
surfaces
́ Complies with the requirements of
DIN 18234

STANDARD  DETAILS
APPEARANCE / COLOR
Surface:
́ Aluminium foil with PET film

SUSTAINABLE  SOLUTIONS
102 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 103
Sarnafil® T ACCESSORIES

VAPOUR- CONTROL LAYERS /


BARRIERS ACCESSORIES

SERVICE  INFORMATION
Sarnavap® Tape F DESCRIPTION CHARACTERISTICS / ADVANTAGES Primer-130 DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnavap® Tape F is a butyl rubber, ́ Finger-lift release liner Primer-130 is a 1-part, ready to use, ́ 1-part ready to use
double-sided adhesion sealing tape with ́ Controlled adhesive stretch range solvent-based primer for improving the ́ Easily applied by brush
a controlled stretch range. ́ High durability adhesion properties of porous ́ Good adhesion to different structural
́ Used only at airtight level substrates before applying Sarnatape. decks and substrates
USES
This product may only be used by experi- APPEARANCE / COLOR USES
enced professionals: Appearance: Primer-130 may only be used by experi-
́ Taping lap splices in Sarnavap® vapour ́ Smooth flat profile enced professionals:
control layers (polyethylene) based Color: ́ Substrate primer for Sarnatape® butyl
material and for attaching Sarnavap® ́ Black rubber adhesive tape

PRODUCT  INFORMATION
vapour control layers to smooth
surfaces. TECHNICAL INFORMATION
Length: 40.00 m
Width: 15 mm
Thickness: 1.00 mm

Sarnatape®-20 DESCRIPTION CHARACTERISTICS / ADVANTAGES Primer-600 DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sarnatape®-20 is a butyl rubber, double- ́ Finger-lift release liner Primer-600 is a synthetic rubber and ́ Proven performance over decades
sided adhesion sealing tape with a ́ Controlled adhesive stretch range resin based 1- part ready to use primer ́ Easily applied
controlled stretch range. ́ High durability for improving the adhesion properties of ́ Flame free application

APPLICATION  INSTRUCTIONS
́ Good adhesion specific Sika® roof membranes. ́ High adhesion to different structural
USES deck types and substrates
Sarnatape®-20 may only be used by APPEARANCE / COLOR USES ́ 1-part ready to use
experienced professionals: Appearance: A primer for applying self-adhesive tech- ́ Increased adhesion for the specific
́ Applied at airtight level for taping of ́ Smooth flat profile nologies onto various substrates: membrane types
seams, connections, terminations and Adhesive: ́ Sarnavap®-5000 E SA ́ Applied by brush or roller
detailing of Sarnafil® roof membranes ́ Anthracite ́ Sarnafil® TG 76 FSA
(FPO) and Sarnavap® vapour control
layers (polyethylene). TECHNICAL INFORMATION
Length: 20.00 m
Width: 20 mm
Thickness: 1.50 mm

Sarnatape®-60 DESCRIPTION CHARACTERISTICS / ADVANTAGES


Sarnatape®-60 is a polyethylene rein- ́ High tack and long-term adhesion

STANDARD  DETAILS
forced fabric waterproof tape which is ́ Contains no halogen or heavy-metal
elastic and pliable. One side is coated in compounds
an acrylic resin adhesive which provides ́ Good durability
high durable adhesion.
APPEARANCE / COLOR
USES ́ White
Sarnatape®-60 may only be used by
experienced professionals: TECHNICAL INFORMATION
́ Taping of seams, connections, ter- Length: 25.00 m
minations and detailing of Sarnafil® Width: 60 mm

SUSTAINABLE  SOLUTIONS
roof membranes (FPO) and Sarnavap® Thickness: Overall 0.34 mm
vapour control layers (polyethylene).

104 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 105


Sarnafil® T ACCESSORIES

SYSTEM OVERVIEW
FALL ARREST SYSTEMS

SERVICE  INFORMATION
INTRODUCTION
Working on roof areas is considered to be one of the most dangerous activities on a construction site for both new and refurbish- CABLE SYSTEM OR SINGLE POINT FALL ARREST ANCHOR
ment projects. It can also be necessary to carry out essential maintenance or repair works on flat roofs during bad weather condi-
tions, including for example: the removal of drain blockages, repairing dome lights and removing snow accumulation. Non thermal insulated
All flat roof working activities are situations with a high risk of roof falls, where the danger can be either, falling at the flat roof
edge or actually falling through openings or the roof itself. These potential hazard combinations should already be respected and Seculine® Vario anchor with Sarnafil® T
Stainless steel ear
considered during the design and planning phase of a project. Seculine Vario Flashing and stainless
steel ear is used to provide permanent
Sarnafil® T Seculine Vario Flashing
Where the building structrue or situation (e.g. with parapets, handrails etc.) cannot prevent a roof fall – a fall back system needs single point fall arrest anchor point.
to be designed according to the following basic principles: Furthermore it can be used for perma- Seculine Vario anchor
nent stainless steel cable system.

PRODUCT  INFORMATION
If the parapet height is < 1.00 m – the flat roof area needs to be equipped with a fall arrest system.

APPLICATION  INSTRUCTIONS
900_020910_N0159C_2011_en

CABLE SYSTEM OR SINGLE POINT FALL ARREST ANCHOR


Stainless steel ear
Thermal insulated
Sarnafil® T Seculine Vario seal set
Seculine® Vario anchor with Sarnafil® T
Seculine Vario seal set and stainless Seculine Vario anchor
steel ear is used to provide permanent
SINGLE POINT FALL ARREST ANCHOR single point fall arrest anchor point. Fur-

STANDARD  DETAILS
thermore it can be used for permanent
ABS Point is used to provide permanent ABS Point anchor stainless steel cable system.
single point fall arrest anchor point.

Sarnafil® T Point Flashing

SUSTAINABLE  SOLUTIONS
900_020910_N0158C_2011_en

900_020910_N0157C_2011_en

106 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 107


Sarnafil® T ACCESSORIES

FALL ARREST SYSTEMS

SERVICE  INFORMATION
ABS Point DESCRIPTION CHARACTERISTICS / ADVANTAGES Seculine® Vario Anchor DESCRIPTION CHARACTERISTICS / ADVANTAGES
The ABS Point is made of stainless steel. ́ Simple assembly for new buildings The Seculine® Vario Anchor is made of ́ Simple assembly for new buildings
ABS Points are used as single attach- and refurbishments stainless steel. and refurbishments
ment points in flat roofs. ́ All components are made of stainless ́ All components are made of stainless
steel USES steel
USES ́ High-quality fall protection system Permanent single point fall arrest anchor ́ High-quality fall protection system
All ABS Point components are used as ́ Extensive accessories point. Furthermore it can be used for ́ Extensive accessories
permanent fall protection systems in permanent stainless steel cable system.
the Sarnafil® flat roof system. There are APPEARANCE / COLOR APPEARANCE / COLOR
different combinations and possibili- Top surface: Top surface:
ties in the application. The ABS Point is ́ Silver ́ Silver

PRODUCT  INFORMATION
used as a single attachment point for a
maximum of 3 persons.

Sarnafil® T Point Flashing DESCRIPTION CHARACTERISTICS / ADVANTAGES Seculine® Vario Seal Set DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® T Point Flashing is a prefabri- ́ Resistant to UV exposure The Seculine® Vario Seal Set consists of: ́ Fast application
cated injection moulded roof point flash- ́ Easy and safe application ́ Seculine® Vario Flashing ́ Visually challenging detail training
ing based on a flexible polyolefin (FPO) ́ Heat weldable ́ Two-piece insulation core ́ Thermal bridge-reducing
with fitted integrated heat shrink sleeve. ́ Fitted integrated heat shrink sleeve ́ Red cap ́ Higher safety

APPLICATION  INSTRUCTIONS
USES APPEARANCE / COLOR USES TECHNICAL INFORMATION
Post flashing on Sarnafil® T flat roof Surface: The Seculine® Vario Seal Set is used for: Diameter tray: 300 × 300 mm
systems. ́ Smooth ́ The professional execution of detail Diameter tube inside: 110 mm
Top surface: connections with Sarnafil® T roof Nozzle length: 400 mm
́ Beige waterproofing membranes.
́ Window grey (RAL 7040)
́ Other colors on request

TECHNICAL INFORMATION
Inside pipe conical diameter:
17 mm, 20 mm, 21 mm, 24 mm
Diameter base plate: 180 mm
Height: 250 mm
Thickness: 2.00 mm

STANDARD  DETAILS
Sarnafil® T Seculine Vario Flashing DESCRIPTION CHARACTERISTICS / ADVANTAGES
Sarnafil® T Seculine Vario Flashing is a ́ Resistant to UV exposure
prefabricated roof post flashing based ́ Easy and safe application
on an FPO waterproofing membrane ́ Heat weldable
which is fitted integrated heat shrink ́ Fitted integrated heat shrink sleeve
sleeve.
APPEARANCE / COLOR
USES Surface:
Post flashing for Seculine Vario fall ́ Smooth
arrest system on Sarnafil® T flat roof Top surface:

SUSTAINABLE  SOLUTIONS
systems. ́ Beige
́ Window Grey (RAL 7040)
́ Other colors on request

TECHNICAL INFORMATION
Inside diameter: 51 mm
Height: 250 mm
Base plate diameter: 180 mm
Length heat shrink
sleeve: 80 mm
Thickness: 1.50 mm

108 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 109


Sarnafil® T ACCESSORIES Sarnafil® T ACCESSORIES

FALL ARREST SYSTEMS APPLICATION TOOLS

SERVICE  INFORMATION
SECULINE® VARIO ANCILLARY PRODUCTS Sarnamatic®-681 DESCRIPTION ́ The Sarnamatic®-681 can be operated
The Sarnamatic®-681 must only be with a singlephase power supply of
Stainless Steel Ear Corner Diverter Universal used for the hot air welding of synthetic 230 VAC, or a 3-phase 400 VAC supply.
USES USES polymer based sheet waterproofing By using the ‘Conversion Kit’, which
To screw on the Seculine® To screw on the Seculine® membrane seams. The Sarnamatic®-681 is available on request, the Sarna-
Vario Fall Arrest Post. Vario Fall Arrest Post. Tra- is equipped with a microcontroller that matic®-681 can be converted from 230
versable Corner Diverter for controls the welding parameters. VAC to 400 VAC, or from 400 VAC to
permanent Stainless Steel All of the necessary instructions and 230 VAC.
Cable System. technical details are also included in the
operating manual which is supplied and CHARACTERISTICS / ADVANTAGES
delivered in every Sarnamatic®-681 pack- The Sarnamatic®-681 welding machine is

PRODUCT  INFORMATION
age. Since we pursue a policy of continu- suitable for use on horizontal and sloped
ous product improvement, we reserve roofs with a suitably supported, solid
Seculine® Vario Type Plate End Lock 90° the right to modify the Sarnamatic®-681 and even surface substrates.
USES USES without prior notification.
To screw on the Seculine® To screw on the Seculine®
Vario Fall Arrest Post. Special Vario Fall Arrest Post. End USES
hood with integrated type Holder 90° with two cable The Sarnamatic®-681 is suitable for the
plate for permanent Seculine® clip for permanent Stainless welding of all Sika Sarnafil® synthetic
Vario Stainless Steel Cable Steel Cable System. waterproofing membranes.
System. When used on a sloping roof the ma-
chine must be secured and guided at

APPLICATION  INSTRUCTIONS
all times. The maximum inclination of
slopes suitable for its use are:
Intermediate Holder Stainless Steel Cable ́ Max. 25° when welding in the direction
USES USES of the roofing slope.
To screw on the Seculine® For permanent Seculine® ́ Max. 15° when welding perpendicular
Vario Fall Arrest Post. Tra- Vario Cable System. to the roofing slope.
versable Intermediate Holder
for permanent Stainless Steel
Cable System. Sika Membrane slitter DESCRIPTION CHARACTERISTICS / ADVANTAGES
The Sika Membrane slitter is generally ́ Easy and safe to use
made of galvanized steel and aluminium. ́ Enables to cut membranes strips
custom-fit on job site
USES ́ Enables to cut the strip to the desired
End Holder Runner Element The Sika Membrane slitter is a tool to cut width around the parapet perimeter
USES USES membrane strips on job site. ́ Can even be used on already applied
To screw on the Seculine® Enables traversable gliding membranes without damage due to a

STANDARD  DETAILS
Vario fall arrest post. End over the Intermediate Holder special protector device
Holder with one cable clip for and Corner Diverter in the per- ́ Tool can be used in upright ergonomic
permanent Stainless Steel manent Stainless Steel Cable position
Cable System. System.

End Holder Straight


USES

SUSTAINABLE  SOLUTIONS
To screw on the Seculine®
Vario Fall Arrest Post. End
Holder straight with two cable
clip for permanent Stainless
Steel Cable System.

110 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 111


Sarnafil® T ACCESSORIES

APPLICATION TOOLS

SERVICE  INFORMATION
Sarnafil® Gas Heating Gun DESCRIPTION OTHER INFORMATION SPARE PARTS FOR LEISTER HAND WELDING TOOL
Device for heating Sarnafil® plastic wa- A commercially available gas cylinder is
terproofing membranes when bonding required on site. Product Uses
connections at low outside temperatures
and for activating the applied adhesive SYSTEM PRODUCT
Sarnacol® T-770 before contact bonding. Sarnacol® T-770 Wide slot nozzle – 20 mm,
Standard welding nozzle for details
15° angled

PRODUCT  INFORMATION
Wide slot nozzle – 20 mm,
Welding nozzle for difficult accessible detail parts
60° angled - horizontal

Spray Application Gun USES SYSTEM PRODUCT


Spray gun to be used for the application SikaRoof® Board Adhesive Wide slot nozzle – 20 mm,
Welding nozzle for difficult accessible detail parts
of SikaRoof® Board Adhesive, polyure- 75° angled - vertical
thane 1- part, foam adhesive.

APPLICATION  INSTRUCTIONS
Wide slot nozzle – 40 mm,
Fitting Tool for Sarnabar DESCRIPTION USES Standard welding nozzle for straight welds
15° angled
Aluminum board with striking surface This tool facilitates the installation of
and tread area. the Sarnabar® edge rail for throat fixa-
tion. Both hands remain free for drilling
and screwing, as the edge rail is held
with the foot by the mounting tool. Tubular nozzle – 5 mm diameter,
Suitable for speed welding nozzle
15° angled

Leister Triac AT / ST DESCRIPTION USES Speed welding nozzle – 8 mm diameter For the installation of Sarnafil® T Welding Cord
Hand welding tool for welding For the hand welding of Sarnafil® roof
membranes. waterproofing in the overlapping of
details and straight welds.

STANDARD  DETAILS
Pressure roller with ball bearings –
Pressure roller in the hot welding process
28 mm / PTFE

Pressure roller with ball bearings –


Pressure roller in the hot welding process
6 mm (brass)

SUSTAINABLE  SOLUTIONS
Chamfering tool along transverse joints of hot
Chamfer tool
welded membranes

Chamfer tool sharpener For the sharpening of chamfer tool

112 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 113


SERVICE  INFORMATION
PRODUCT  INFORMATION
APPLICATION  INSTRUCTIONS
APPLICATION­ INSTRUCTIONS
BASICS116
MECHANICALLY FASTENED ROOF SYSTEM 124
GRAVEL BALLASTED ROOF SYSTEM  130
INVERTED ROOF SYSTEM 134
UTILITY ROOF SYSTEM 138
GREEN ROOF SYSTEM 142
ADHERED ROOF SYSTEM 146

STANDARD  DETAILS
ROOF REFURBISHMENT 151

SUSTAINABLE  SOLUTIONS
APPLICATION INSTRUCTIONS

BASICS

SERVICE  INFORMATION
BASICS The basis for the application of Sarnafil® T roof waterproofing membranes beside the GENERAL Sarnafil® T Sarnafil® T membranes will be homogenous joined by thermal welding process.
Roof Handbook Sarnafil® T are the application manual for Sarnafil® TG / TS and the MEMBRANE WELDING Sarnafil® TG / TS membranes must be prepared for welding. During installation and
latest versions of product data sheets. in case of repair, different cleaning and seam preparation procedures may apply.
In addition to that the product information, the standard details and the inputs Sarnafil® T membranes must be overlapped by 80 mm for the loose and adhered roof
regarding mechanically fastened, ballasted and adhered roof systems. system whilst 120 mm for the mechanically fastened system. Regarding detailing we
refer to application manual Sarnafil® TG / TS and the width range of prefarbricated
DELIVERY / PACKAGING / STORAGE Sarnafil® T roof waterproofing membranes will be delivered in rolls – individually parts to be offered.
wrapped and palletized. Building site storage of membranes horizontally, on palettes
and protected against humidity, dirt, dust and exposure. Welding tools
Only Sika recommended welding tools should be used. Sarnafil® T roof waterproofing
MEMBRANE CUTTING Cut Sarnafil® T roof waterproofing membrane with a scissor, knife or Sika® Membrane membranes will be hot welded, either with hand welder or automatic welding machine.

PRODUCT  INFORMATION
slitter. Please take also notice of the range of available strips in our delivery program.
Test welding
SUBSTRUCTURE / FIRE PROTECTION Depending on the roof system adjustment with the subconstruction need to take Before welding the actual roof membrane, a test weld must be carried out to check
place. Your Sika roofing specialist can support you perfectly. the settings of the hand welder and / or the automatic welding machine. The test
Certain Sarnafil® T roof waterproofing systems are resistant and therefore approved weld must be also carried out to check local site conditions during a working day.
against spreading of fire on roofs without protective or covering layers. Fire protec-
tion requirements of specific country need to be considered. Hand welding carried out in three steps

SUPPORT LAYER A support layer need to be installed above trapezoidal metal deck constructions.
This can either be thermal insulation with sufficient compression strength or plain Pre-welded area

metal sheet.

APPLICATION  INSTRUCTIONS
m
m
35 mm 20

VAPOUR CONTROL / BARRIER LAYER The type of vapour control / barrier layer to be chosen depends on the roof build-up
Overlap
and boundary conditions (indoor and outdoor clima). In case of not airtight sub –
constructions (wood planking, trapezoidal metal sheets, prefabricated elements etc.),
vapour control / barrier layer need also take over the function of airtight layer.
1. Spot weld overlap area must be clean and 2. Pre-weld the rear overlap area that a 35 mm 3. Final weld the 35 mm opening area. Roll the
dry. opening remains. pressure roller fully across the seam.
THERMAL INSULATION LAYER Depending on the roof system to be chosen, thermal insulation layer will be loosely
laid, mechanically fastened or adhered. Guidelines of thermal insulation producer
need to be followed. Thermal insulation plates applied in staggered bond pattern. T- and cross joints

SEPARATION- / LEVELLING LAYER If needed separation- / levelling layer installed based on the chosen roof build-up.

REFURBISHMENTS Existing roof must be assessed carefully before a suitable refurbishment proposal
can be prepared. Visual inspection of the buried roof layers should be made by opening
the roof or taking core samples. The design should consider the following:
́ Condition of the roofing membrane and all flashing details

STANDARD  DETAILS
́ Building regulations
́ Whether the thermal insulation is dry
Welds at transverse joints. By proper arrange- To achieve proper welding, all transverse joints Weld the membrane over the chamfered area.
́ Whether the vapour control layer functions adequately
ment of Sarnafil® TG / TS, all seams can be re- of all Sarnafil® TG / TS thickness, for manual
́ Whether the roof structure can support the design loads
duced to straight welded seams and transverse and automatic welding have to be chamfered.
́ Whether roof drainage is sufficient joint (T-joint). Cross joints are to be avoided.
́ Wheter adjacent construction is sound or requires work

Sika Roofing guidelines and application instructions for new roofs also apply to refur- Seam check after welding
bishment work. If only certain parts of the roof are to be refurbished, it is advisable
to consider separating the new areas from the old areas by installing area dividers or

SUSTAINABLE  SOLUTIONS
waterstops. This will prevent any leaks in the old roof from affecting the performance
of the new roof.

All seams must be checked after they have


completely cooled by contractor according to
Sarnafil® TG / TS application manual.

116 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 117


APPLICATION INSTRUCTIONS

BASICS

SERVICE  INFORMATION
PERIMETER SECUREMENT At all upstands and penetrations wider than 50 cm Sarnafil® T membrane must SARNABAR CONNECTION
be secured with Sarnabar® either to the horizontal or vertical surface. The number
and type of fasteners per linear meter depend on the substrate and the windload
(mechanically fastened system). At least four fasteners per meter must be used. The
Sarnafil® T Welding Cord secures Sarnafil® T membrane against tearing and peeling
due to wind uplift. In the adhered roof system no Sarnafil® T Welding Cord need to be
installed.

PRODUCT  INFORMATION
Version 1 – leave a 10 mm clearance between Version 2 – cover the bar with the Sarnabar®
bar ends. Do not fasten in hole nearest bar Connection Clip.
end. Cover the bar ends with a piece of
Sarnafil® T membrane and weld in in place.

PERIMETER FLASHING Mechanically fastened


A levelling layer must be installed between Sarnafil® T membrane and rough or
uneven sub-strates. Screw the Sarnabar® perimeter securement over the Sarnafil® T
membrane at the base of the upstand, either to the vertical or horizontal surface. The
number of fasteners per linear meter depend on the substrate and the windload.

APPLICATION  INSTRUCTIONS
1

2
Detail 2
3
7

≥ 150 mm
4
8
5
9
Detail 1

6
900_020910_N0004C_1908_en

Detail 1 Detail 2

STANDARD  DETAILS
Sarnabar® Perimeter Additional Fastening for
Securement Vertical (Alternative) Parapet Height > 800 mm
900_020910_N0096C_1911_en

900_020910_N0112C_1909_en

Mechanically fastened and Adhered roof systems


ballasted roof systems
1 Hot-air weld 6 Sarnabar® with Sarnafast®

SUSTAINABLE  SOLUTIONS
2 Sarnafil® S-Sealing Tape 10/10 (if required) Fasteners and Sarnafil® T Welding Cord
3 Sarnafil® T Metal Sheet 7 Sarnafil® T membrane cover strip
4 Metal clip 8 Hot-air weld
5 Appropriate S-Felt levelling layer (if required) 9 Sarnafil® T membrane

118 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 119


APPLICATION INSTRUCTIONS

BASICS

SERVICE  INFORMATION
PERIMETER FLASHING Fully adhered PERIMETER FLASHING Tape Adhered
Perimeter flashings are formed using strips of Sarnafil® T membrane. The flashing Perimeter flashings are formed using strips of Sarnafil® T membrane. The flashing
strips are to be fully adhered with Sarnacol® T-660 adhesive to the substrate and strips are to be adhered with strips of SikaRoof® Tape P to the substrate and welded
welded to the field sheet. The substrate must be free of ridges, and the flashing to the field sheet. When applying SikaRoof® Tape P, the substrate must be dry,
must be attached with a good adhesive bond. Form corners, mitres and curved details stable, clean and free of dust and grease.
on site or weld prefabricated Sarnafil® T pieces to the membrane.
Maximal perimeter height 300 mm.
1 5 1 5

2 6 2
6

PRODUCT  INFORMATION
3 7 3
7

≥ 150 mm
≥ 150 mm
4 8 4
8

Detail 1
Detail 1

900_020910_N0128C_2002_en

900_020910_N0003C_1908_en

Detail 1
Sarnabar® Perimeter
Detail 1 Securement Vertical (Alternative)

APPLICATION  INSTRUCTIONS
Sarnabar® Perimeter
Securement Vertical (Alternative)

1 Metal capping 6 Sarnabar® with Sarnafast® Fasteners


2 Sarnafil® S-Sealing Tape 10/10 (if required) and Sarnafil® T Welding Cord
3 Metal clip 7 Hot-air weld
1 Metal capping 6 Sarnabar® with Sarnafast® Fasteners and 4 SikaRoof® Tape P 8 Sarnafil® T membrane
2 Sarnafil® S-Sealing Tape 10/10 (if required) Sarnafil® T Welding Cord 5 Sarnafil® T membrane adhered
3 Metal clip 7 Hot-air weld
4 Sarnacol® T-660 adhesive 8 Sarnafil® T membrane
5 Sarnafil® T membrane adhered

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
_en
909
98O_1
0_ N00
091
_02
900

120 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 121


APPLICATION INSTRUCTIONS

BASICS

SERVICE  INFORMATION
PERIMETER FLASHING Roof Trim
Sarnafil® S-Sealing Tape 10/10 should be placed between the Sarnafil® T Metal Sheet
flashing and the substrate to prevent penetration of wind-driven water.

900_020910_N0126O_2011_en

PRODUCT  INFORMATION
200
mm
2
4

3 1

APPLICATION  INSTRUCTIONS
3m
125 m
mm

1 Sarnafil® S-Sealing Tape 10/10 4 Tape to avoid full weld


2 Connection plate 5 Sarnafil® T 125 mm strip
3 Sarnafil® T Metal Sheet 6 Sarnafil TG/TS membrane

UPSTAND FLASHING To achieve good adhesion, apply primer to both surfaces (metal counter flashing or
sheet, and masonry or plaster). At the top metal counter flashing or sheet, always
install closed-cell material as backing rod before applying the Sarnaplast®-2235 or
Sikaflex®-11 FC sealant.

STANDARD  DETAILS
900_020910_0045C_1911_en

900_020910_0047C_1911_en

SUSTAINABLE  SOLUTIONS
Sarnafil® T Metal Sheet Counter flashing

122 ROOFING HANDBOOK Sarnafil® T


APPLICATION INSTRUCTIONS

MECHANICALLY FASTENED
ROOF SYSTEM

SERVICE  INFORMATION
900_020910_N0009O_1909_en
CHARACTERISTICS / ADVANTAGES
́ Mechanically fastened roofs are the
most cost efficient for exposed roofing 1
applications
́ The fastest installation speed is
achieved with mechanically fastening
2
́ Sarnafil® TS 77 roof waterproofing
membrane has special polyester re-
inforcement, enabling high wind load
3
resistance
́ Installation is almost not weather

PRODUCT  INFORMATION
dependent
5 4

1 Sarnafil® TS 77 membrane 4 Vapour control layer


2 Sarnafast® spot fastening system 5 Roof deck
3 Thermal insulation

APPLICATION  INSTRUCTIONS
SYSTEM DESCRIPTION

Thermal insulation fastening


Before the Sarnafil® TS 77 roof waterproofing membrane is installed, the insulation boards must be secured to the roof deck us-
ing appropriate Sarnafast® fasteners and insulation washers. The number of fasteners must meet local regulations and building
codes. The minimum is one fastener per insulation board or on fastener per m².

Fire separation- / Protection layer


A separation- / fire protection layer S-Glass Fleece 120 g/m² to be installed above thermal insulation where it is required by fire
regulation!
SYSTEM DESCRIPTION
Exposed roofs with Sarnafil® TS 77 roof waterproofing membranes can be mechanically fastened Types of spot fastening systems
Sarnafast®

STANDARD  DETAILS
using the Sarnafast® Spot Fastening System. These lightweight systems meet all the requirements
Tube Spot Fastening System
for modern flat roofing. using polyamide tubes

900_020910_N0129C_2002_en

Sarnafast®

SUSTAINABLE  SOLUTIONS
Spot Fastening System
using metal washers

900_020910_N0130C_2002_en

124 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 125


APPLICATION INSTRUCTIONS

MECHANICALLY FASTENED
ROOF SYSTEM

SERVICE  INFORMATION
Application of spot fastening systems 120 mm Steel decks
Sarnafil® TS 77 is fastened using Sar- The deck must be galvanized steel with a minimum thickness of 0.63 mm, yield
nafast® fasteners and washers / tubes 85 mm 35 mm strength of minimum S280 according EN 10147 or equal. The suitability of the deck
along the marked line 35 mm from the must be verified by an architect, structural engineer or other qualified specialist. Ori-
edge of the membrane. ent rows of bars and fasteners perpendicular to the direction of the deck ribbing. The
fasteners are self-tapping in decks up to 1.25 mm thick. Thicker decks might require
pilot holes. All fasteners must penetrate the top flange of the deck. All fasteners
900_020910_N0011C_1911_en
used must be approved by Sika Roofing.

Aerated concrete decks (Cellular, Gas or Lightweight)

PRODUCT  INFORMATION
All roofing applications over concrete decks require an on-site pullout test. Conduct
Where additional fastening is required, 200 mm the test immediately after setting the fastener in order to confirm fastener perfor-
Sarnafast® fasteners and washers / mance.
tubes are installed through the roof Heed the following:
waterproofing membrane (intermediate ́ All fasteners used must be approved by Sika Roofing
fastening). ́ Do not alter the perforation of the bars
Cover the rows of Sarnafast® fastening ́ Install fasteners using an electric dynamometric screw driver
system with a 200 mm wide membrane
cover strip and weld both sides.
900_020910_N0132C_2002_en 900_020910_N0070C_1911_en

APPLICATION  INSTRUCTIONS
Planning and layout Reinforced, precast or pre-stressed concrete decks
The spacing and numbers of fasteners and washers depend on the following: Concrete quality must be at least C20/25.
́ Building regulations and standards
́ Wind uplift forces
́ Elongation limit of the roof waterproofing membrane
́ Pullout strength of the fasteners
́ Available points of attachments to the deck
́ Type and quality of roof deck 900_020910_N0131C_2002_en

Sika determines the fastening pattern and calculates the fastener spacing depending on the substrate and the design load of the
relevant fastener for the local situation of project (Wind Load Calculation page).
900_020910_N0017C_1911_en

Wood decks
Approved fasteners must be used for fastening roofing to wood decks.

STANDARD  DETAILS
3
The selection of fastener depends on these factors:
́ Quality and thickness of the wood
4
́ Embedment depth and pullout strength
́ Type of wood preservative used

900_020910_N0022C_1911_en Mechanical fastening on wood decks


Material mechanical minimum attachment thickness:
1 5 ́ Plywood/OSB ≥ 22 mm
́ Wood planking ≥ 24 mm

SUSTAINABLE  SOLUTIONS
́ Chipboard not allowed
900_020910_N0100C_1909_en

2
Plywood decks
Observe local codes and standards regarding application, fastening and fire protection.

Board decks
́ Boards should be tongue and grooved
́ Only wood treated with aqueous, salt-based preservative may be used
1 Perimeter Sarnabar® with Sarnafil® T Welding Cord 3 Sarnafast® spot fastening system with cover strip
2 Sarnafast® spot fastening system along the edge of roof 4 Sarnafast® row termination plate ́ Sika Roofing accepts no liability for damage to the roof waterproofing membrane
waterproofing membrane 5 Direction of metal deck ribs caused by insect infestation

126 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 127


APPLICATION INSTRUCTIONS

MECHANICALLY FASTENED
ROOF SYSTEM

SERVICE  INFORMATION
Steel Wood

6 6 6 6
5 2 5 2
900_020910_N0025C_2009_en 1

4 1 4
900_020910_N0020C_1911_en

3 3
1

PRODUCT  INFORMATION
900_020910_N0023C_2009_en

1
900_020910_N0011C_1911_en

Reinforced concrete
Layer No. Function Material Attachment

APPLICATION  INSTRUCTIONS
6 6 1 Roof deck Steel
5 2
Reinforced concrete
Aerated concrete
4 Wood
1
2 Levelling- and protection layer S-Felt A-300 Loose laid
(if required) Sikaplan® W Felt 500 PP Loose laid
3
S-Felt S-800 Loose laid
900_020910_N0014C_1911_en
3 Vapour control layer Sarnavap®-1000 E Loose laid
Sarnavap®-2000 E Loose laid
1 Sarnavap®-3000 M Loose laid
S-Vap-4000 E SA FR Self adhered
Sarnavap®-5000 E SA FR Self adhered
Sarnavap®-5000 E SA Self adhered
900_020910_N0018C_1911_en

STANDARD  DETAILS
4 Thermal insulation Mechanically fastened

Aerated concrete 5 Separation- and fire protection layer S-Glass Fleece 120 Loose laid
(if required)

6 Roof waterproofing membrane Sarnafil® TS 77 Mechanically fastened


6 6
5 2 Sarnafil® TS 77 E Mechanically fastened

4
1

SUSTAINABLE  SOLUTIONS
3

900_020910_N0073C_1911_en

900_020910_N0070C_1911_en

128 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 129


APPLICATION INSTRUCTIONS

GRAVEL BALLASTED ROOF SYSTEM

SERVICE  INFORMATION
CHARACTERISTICS / ADVANTAGES 900_020910_N0032O_1909_en
́ Fast and easy installation
́ No penetration of the roof deck
́ Easy to maintain, low maintenance
costs 2 1
́ Protection of the roof waterproofing
membrane against environmental
exposure and mechanical damage
́ The noncombustible properties of
3
the gravel contribute significant to
the fire resistance of the whole roof.

PRODUCT  INFORMATION
The gravel also prevents flames from
4
spreading across the roof surface

1 Gravel ballast 4 Vapour control layer


2 Sarnafil® TG 66 membrane 5 Roof deck
3 Thermal insulation

APPLICATION  INSTRUCTIONS
80 mm

SYSTEM DESCRIPTION
́ The build-up is ballasted with well–
rounded and washed gravel 16/32 mm
of at least 50 mm and 80 kg/m²,
securing the roof waterproofing mem-
brane against wind uplift
́ If crushed gravel is used, a protection
SYSTEM DESCRIPTION layer is required on top of the roof
In gravel ballasted roof systems, the Sarnafil® TG 66 roof waterproofing membrane is covered and waterproofing membrane
́ Sarnafil® TG 66 roof waterproofing

STANDARD  DETAILS
ballasted against wind uplift and other exposures with a layer of gravel. Conventional gravel ballasted
membrane and other roof compo-
roofs have been established in most markets for many years and are suitable on most flat roofs and nents, including thermal insulation, 900_020910_N0139C_2002_en

bearing structures. are loosely laid

SUSTAINABLE  SOLUTIONS
130 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 131
APPLICATION INSTRUCTIONS

GRAVEL BALLASTED ROOF SYSTEM

SERVICE  INFORMATION
Steel
Layer No. Function Material Attachment

7 1 Roof deck Steel


7 Reinforced concrete
6 6 Wood
5 5
2
2 Levelling- and protection layer S-Felt A-300 Loose laid
(if required) Sikaplan® W Felt 500 PP Loose laid
4 1 S-Felt S-800 Loose laid
900_020910_N0029C_1909_en
3 Vapour control layer Sarnavap®-1000 E Loose laid

PRODUCT  INFORMATION
3 Sarnavap®-2000 E Loose laid
Sarnavap®-3000 M Loose laid
1 S-Vap-4000 E SA FR Self adhered
900_020910_N0026C_1909_en
Sarnavap®-5000 E SA FR Self adhered
Sarnavap®-5000 E SA Self adhered

4 Thermal insulation Loose laid

5 Roof waterproofing membrane Sarnafil® TG 66 Loose laid

6 Separation-, levelling- and protection S-Felt A-300 Loose laid


Reinforced concrete
layer (if required) Sikaplan® W Felt 500 PP Loose laid
S-Felt S-800 Loose laid

APPLICATION  INSTRUCTIONS
7 7 S-Felt T-300 Loose laid

6 6 7 Ballast Gravel Loose laid


5 5
2

4
1
3

900_020910_N0027C_1909_en

STANDARD  DETAILS
900_020910_N0028C_1909_en

Wood

7 7
6 6
5 5
2

4 1

SUSTAINABLE  SOLUTIONS
900_020910_N0031C_1909_en

1
900_020910_N0030C_1909_en

132 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 133


APPLICATION INSTRUCTIONS

INVERTED ROOF SYSTEM

SERVICE  INFORMATION
CHARACTERISTICS / ADVANTAGES 900_020910_N0037O_1909_en

́ Fast and easy installation 1


́ No penetration of the roof deck 2
́ Additional protection of the roof
waterproofing membrane
́ High fire resistance

PRODUCT  INFORMATION
5

1 Ballast 4 Sarnafil® TG 66 membrane


2 Filter layer 5 Levelling- and protection layer
3 Thermal insulation XPS 6 Roof deck

APPLICATION  INSTRUCTIONS
SYSTEM DESCRIPTION
́ The build-up is ballasted with gravel,
pavings or green roof securing the
thermal insulation against wind uplift
́ The filter layer prevents small particles
from penetrating gaps and voids into
thermal insulation
́ Sarnafil® TG 66 roof waterproofing
membrane and other roof compo-
SYSTEM DESCRIPTION nents, including thermal insulation,
In this type of construction the principal thermal insulation material is applied on top of the Sarnafil® are loosely laid

STANDARD  DETAILS
TG 66 roof waterproofing membrane so that the complete roof construction including roof covering 900_020910_N0137C_2002_en

is kept at warm temperatures during the winter months and at moderate temperatures during the
80 mm
summer months; the system is also referred to as a “protected membrane”, or “upside down” roof.

SUSTAINABLE  SOLUTIONS
134 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 135
APPLICATION INSTRUCTIONS

INVERTED ROOF SYSTEM

SERVICE  INFORMATION
Reinforced concrete

6 6
5 5

4
4
3

PRODUCT  INFORMATION
3
2

1 1

900_020910_N0033C_1909_en 900_020910_N0034C_1909_en

APPLICATION  INSTRUCTIONS
6 6

5 5

4
4
3

3
2

1 1

STANDARD  DETAILS
900_020910_N0035C_1909_en 900_020910_N0036C_1909_en

Layer No. Function Material Attachment

1 Roof deck Reinforced concrete

2 Levelling- and protection layer S-Felt A-300 Loose laid


(if required) Sikaplan® W Felt 500 PP Loose laid
S-Felt S-800 Loose laid
Thermal insulation Loose laid

SUSTAINABLE  SOLUTIONS
3 Roof waterproofing membrane Sarnafil® TG 66 Loose laid

4 Thermal insulation XPS Loose laid

5 Filter layer S-Felt VS-140 Loose laid

6 Ballast Gravel Loose laid


Paving slabs Loose laid

136 ROOFING HANDBOOK Sarnafil® T


APPLICATION INSTRUCTIONS

UTILITY ROOF SYSTEM

SERVICE  INFORMATION
CHARACTERISTICS / ADVANTAGES 900_020910_N0044O_1909_en

́ The roof waterproofing membrane


1
is protected against any aggressive
environmental exposure and mechani-
cal damage 2
́ The natural non – combustible proper-
ties of the paved wearing surface 3
contribute significantly to the fire
resistance of the whole roof
4

PRODUCT  INFORMATION
5

1 Paving slabs / concrete 4 Thermal insulation


2 Protection- and slip layer 5 Vapour control layer
3 Sarnafil® TG 66 membrane 6 Roof deck

APPLICATION  INSTRUCTIONS
80 mm

SYSTEM DESCRIPTION
́ The build-up is ballasted with pavings
or concrete slab securing the thermal
insulation against wind uplift
́ Slip- and protection layer to be laid
above roof waterproofing membrane
in case of concrete slab on top
́ Sarnafil® TG 66 roof waterproofing
membrane and other roof compo-
SYSTEM DESCRIPTION nents, including thermal insulation,
Create more utilized space and bring additional value to the building. Further on that they generate are loosely laid

STANDARD  DETAILS
an increased return on investment by using the roof for a car park, restaurant area or any other 900_020910_N0136C_2002_en

viable purpose or facility.

SUSTAINABLE  SOLUTIONS
138 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 139
APPLICATION INSTRUCTIONS

UTILITY ROOF SYSTEM

SERVICE  INFORMATION
Reinforced concrete
Layer No. Function Material Attachment

1 Roof deck Reinforced concrete


8 8
2 Levelling- and protection layer S-Felt A-300 Loose laid
6 6 (if required) Sikaplan® W Felt 500 PP Loose laid
5 5 S-Felt S-800 Loose laid
2
3 Vapour control layer Sarnavap®-1000 E Loose laid
4 Sarnavap®-2000 E Loose laid
1 Sarnavap®-3000 M Loose laid

PRODUCT  INFORMATION
S-Vap-4000 E SA FR Self adhered
3 Sarnavap®-5000 E SA FR Self adhered
Sarnavap®-5000 E SA Self adhered
900_020910_N0043C_1909_en
4 Thermal insulation Loose laid
1 5 Roof waterproofing membrane Sarnafil® TG 66 Loose laid

6 Protection- and slip layer S-Felt GK-400 Loose laid


(if concrete deck above)
900_020910_N0041C_1909_en

7 Separation-, levelling- and protection S-Felt A-300 Loose laid


layer (if required) Sikaplan® W Felt 500 PP Loose laid

APPLICATION  INSTRUCTIONS
S-Felt S-800 Loose laid
8 8 S-Felt T-300 Loose laid

7 7 8 Ballast Concrete Loose laid


5 5 Paving slabs
2

4
1
3

900_020910_N0040C_1909_en

STANDARD  DETAILS
900_020910_N0038C_1909_en

SUSTAINABLE  SOLUTIONS
140 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 141
APPLICATION INSTRUCTIONS

GREEN ROOF SYSTEM

SERVICE INFORMATION
CHARACTERISTICS / ADVANTAGES 900_020910_N0050O_1909_en
́ Reducing heat – island effect in cities
́ Enhancing the aesthetics of the build-
ing
́ Improved thermal performance of the 1
building
́ A natural environment on the roof with 3 2
natural Co absorption
²

PRODUCT  INFORMATION
4

1 Green roof 4 Thermal insulation


2 Drainage-, filter- and protection layer 5 Vapour control layer
3 Sarnafil® TG 66 membrane 6 Roof deck

APPLICATION  INSTRUCTIONS
80 mm

SYSTEM DESCRIPTION
Green roof systems are classified as:

Extensive
Have a shallow growing medium with
small plants and require low maintenance.
Soil with plants 50 – 150 mm thick and
50 – 170 kg/m². Minimum slope of 1.50%.

SYSTEM DESCRIPTION
In so called “Green Roofs” soil, or a suitable plant growing medium, is built-up and planted with 900_020910_N0135C_2002_en

STANDARD  DETAILS
selected vegetation over the roof waterproofing membrane. Green roofs can therefore make a
significant contribution and present practical solutions in the quest for sustainability, increased
biodiversity and quality of life.

Intensive
Have a thicker soil layer with additional 80 mm
drainage for planting larger plants, bushes
and small trees, thus creating roof gar-
dens. Soil with plants minimum 150 mm

SUSTAINABLE  SOLUTIONS
thick and 170 kg/m. Suitable for roof
systems without slope.

900_020910_N0134C_2002_en

142 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 143


APPLICATION INSTRUCTIONS

GREEN ROOF SYSTEM

SERVICE  INFORMATION
Reinforced concrete

7
5
4 7

6
3 4

PRODUCT  INFORMATION
3
2
2

1
1

900_020910_N0048C_1909_en
900_020910_N0049C_1909_en

Layer No. Function Material Attachment

APPLICATION  INSTRUCTIONS
1 Roof deck Reinforced concrete

2 Vapour control layer Sarnavap®-1000 E Loose laid


Sarnavap®-2000 E Loose laid
Sarnavap®-3000 M Loose laid
S-Vap-4000 E SA FR Self adhered
Sarnavap®-5000 E SA FR Self adhered
Sarnavap®-5000 E SA Self adhered

3 Thermal insulation Loose laid

4 Roof waterproofing membrane Sarnafil® TG 66 Loose laid

5 Protection-, drainage- and filter layer Aquadrain 550 Loose laid


extensive green roof

6 Protection-, drainage- and filter layer SikaRoof® Loose laid

STANDARD  DETAILS
intensive green roof Drainage Layer 20L2F

7 Ballast Green roof Loose laid

SUSTAINABLE  SOLUTIONS
144 ROOFING HANDBOOK Sarnafil® T
APPLICATION INSTRUCTIONS

ADHERED ROOF SYSTEM

SERVICE  INFORMATION
CHARACTERISTICS / ADVANTAGES 900_020910_N0065O_1909_en

́ No penetrations of the roof deck are required


́ Very low noise emissions during installation
́ Easy refurbishment of existing bitumen roofs
1

PRODUCT  INFORMATION
3

1 Sarnafil® TG 76 membrane, adhered 3 Vapour control layer,


2 Thermal insulation, adhered or loosely laid
adhered or mechanically fastened 4 Roof deck

80 mm
SYSTEM DESCRIPTION

APPLICATION  INSTRUCTIONS
Build-up fully adhered
Roof waterproofing membrane adhered with ad-
hesive or self adhered membrane to the substrate
underneath.
All other layers to be adhered to each other.

900_020910_N0133C_2002_en

SYSTEM DESCRIPTION Build–up adhered roof waterproofing membrane


This system is designed to fulfil the highest aesthetic requirements! The membranes can be adhered combined with mechanically fastened system
Vapour control layer loose laid and mechanically

STANDARD  DETAILS
to flat, curved or sloped roof of practically any shape and configuration.
fasten of thermal insulation onto roof deck.

900_020910_N0160C_2011_en

SUSTAINABLE  SOLUTIONS
146 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 147
APPLICATION INSTRUCTIONS

ADHERED ROOF SYSTEM

SERVICE  INFORMATION
Steel Wood

4 4 4 4

1
3 3 1
900_020910_N0061C_1909_en

900_020910_N0067C_1909_en

2 2

PRODUCT  INFORMATION
1
1
900_020910_N0056C_1909_en

900_020910_N0059C_1909_en

Reinforced concrete Steel Reinforced concrete

APPLICATION  INSTRUCTIONS
4 4 4 4

3 3 3
1

2 2 2
900_020910_N0057C_1909_en
1
900_020910_N0075C_1909_en

1 1

900_020910_N0055C_1909_en 900_020910_N0074C_1909_en

STANDARD  DETAILS
Adhered concrete
Layer No. Function Material Attachment

4 4 1 Roof deck Steel


Reinforced concrete
Aerated concrete
3 Wood
1
2 Vapour control layer Sarnavap®-1000 E Loose laid

SUSTAINABLE  SOLUTIONS
2 Sarnavap®-2000 E Loose laid
Sarnavap®-3000 M Loose laid
900_020910_N0068C_1909_en
S-Vap-4000 E SA FR* Self adhered
Sarnavap®-5000 E SA FR* Self adhered
1 Sarnavap®-5000 E SA Self adhered

3 Thermal insulation Adhered


Mechanically fastened
900_020910_N0060C_1909_en
4 Roof waterproofing membrane Sarnafil® TG 76 Felt PS Adhered
Sarnafil® TG 76 FSA Self adhered
* Not approved for fully bonded systems

148 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 149


APPLICATION INSTRUCTIONS APPLICATION INSTRUCTIONS

ADHERED ROOF SYSTEM ROOF REFURBISHMENT

SERVICE  INFORMATION
SikaRoof® Board Adhesive
Sarnafil® TG 76 Felt PS E
Sarnafil® TG 76 Felt PS

Sarnafil® TG 76 FSA
Sarnacol®-2142 V
Sarnacol®-2142 S

Sarnacol® T-660
Sarnafil® TG 66

PRODUCT  INFORMATION
Membranes
Sarnafil® TG 76 Felt PS / TG 76 Felt PS E

Fully Adhered

Application Self adhered

Insulation Adhesive

Flat
1) 1)
Area Sloped

Detailing / Upstands

APPLICATION  INSTRUCTIONS
1)
Concrete  
1)
Metal / Steel  
1)/2)
Wood (e.g. OSB, Plywood)

Metal Composite Panel 3)


1)
Bitumen – slated or sanded  

Substrates Polyester, hard and soft PVC

EPS / XPS

Coverboards

Mineralwool
1)/2) SYSTEM DESCRIPTION
PIR – with glass tissue facer
1)/2) Roofs have limited lifespan. Old or inadequate roofs should be refurbished before the building

STANDARD  DETAILS
suffers deterioration or damage.
PIR – with aluminium composite facer
Sika Roofing Systems are ideally suited for refurbishment work. Your local sales organisation can
VOC Free
provide all the necessary technical support.
Approved
1)
Slope > 10°, additional mechanical securement is required till adhesive has set
1)
Primer-600
2)
Primer-780
3)
Product specific approval on request

SUSTAINABLE  SOLUTIONS
150 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 151
APPLICATION INSTRUCTIONS

ROOF REFURBISHMENT

SERVICE  INFORMATION
Refurbishment of existing roof constructions becoming more and more common and Sika has various systems for all kind GREEN ROOF SYSTEM ́ Green roof (extensive or intensive)
of substrates. ́ Aquadrain-550 (extensive) or
SikaRoof® Drainage Layer 20L2F
́ Bitumen Roofs (intensive), drainage, filter- and
́ Metal Roofs protection layer
́ Singly-ply Synthetic Roofs EPDM, PVC, FPO ́ Sarnafil® TG 66 membrane, loose laid
́ S-Felt T 300, separation layer
For the selection of the right refurbishment system, a specific project survey and assessment has to be undertaken. ́ Existing synthetic or
Please contact the Technical Services Department of your local Sika company for assistance. bituminous roofing
All roof build-up’s shall be reviewed by a building physic specialist / engineer.

PRODUCT  INFORMATION
OVERLAYING OR REPLACING EXISTING SYNTHETIC OR BITUMINOUS ROOFING WITHOUT THERMAL INSULATION UPGRADE 900_020910_N0082C_1909_en

ADHERED ROOF SYSTEM System A


MECHANICALLY FASTENED ́ Sarnafil® TS 77 membrane, ́ Sarnafil® TG 76 FSA, self-adhered
ROOF SYSTEM mechanically fastened ́ Primer 600, primer
́ S-Felt T 300, separation layer ́ Bituminous roofing
́ Existing synthetic or
bituminous roofing System B
900_020910_N0079C_1909_en

900_020910_N0145C_2009_en
́ Sarnafil® TG 76 Felt PS, adhered

APPLICATION  INSTRUCTIONS
́ Sarnacol®-2142, adhesive
́ Bituminous roofing
GRAVEL BALLASTED ROOF SYSTEM ́ Gravel ballast
́ Protection layer, if required Above synthetic roofing membrane specific project approval by Sika Technical Department needed.
́ Sarnafil® TG 66 membrane, loose laid
́ S-Felt T 300, separation layer Note: In general, it is recommended to remove the existing synthetic or bituminous roofing before installing a new membrane.
́ Existing synthetic or
bituminous roofing

900_020910_N0080C_1909_en

UTILITY ROOF SYSTEM ́ Concrete slab


́ S-Felt GK 400, slip- and protection layer

STANDARD  DETAILS
́ Sarnafil® TG 66 membrane, loose laid
́ S-Felt T 300, separation layer
́ Existing synthetic or
bituminous roofing

900_020910_N0081C_1909_en

SUSTAINABLE  SOLUTIONS
152 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 153
APPLICATION INSTRUCTIONS

ROOF REFURBISHMENT

SERVICE  INFORMATION
GREEN ROOF SYSTEM ́ Green Roof (extensive or intensive)
OVERLAYING OR REPLACING EXISTING SYNTHETIC OR BITUMINOUS ROOFING WITH THERMAL INSULATION UPGRADE ́ Aquadrain-550 (extensive) or
SikaRoof® Drainage Layer 20L2F
(intensive), drainage, filter- and
protection layer
́ Sarnafil® TG 66 membrane, loose laid
́ New / additional thermal Insulation,
loose laid
́ Existing synthetic or
bituminous roofing
MECHANICALLY FASTENED ́ Sarnafil® TS 77 membrane,

PRODUCT  INFORMATION
ROOF SYSTEM mechanically fastened
́ S-Glass Fleece-120, separation layer,
if required
́ New thermal Insulation,
mechanically fastened
́ Existing synthetic or
bituminous roofing
900_020910_N0148C_2009_en
900_020910_N0147C_2009_en

APPLICATION  INSTRUCTIONS
GRAVEL BALLASTED ROOF SYSTEM ́ Gravel ballast ADHERED ROOF SYSTEM – ́ Sarnafil® TG 76 FSA, self-adhered
́ Protection layer, if required EXISTING BITUMINOUS ROOFING ́ Primer 600 / 780, if required
́ Sarnafil® TG 66 membrane, loose laid ́ New thermal Insulation, adhered
́ New / additional thermal Insulation, ́ SikaRoof® Board Adhesive, adhesive
loose laid ́ Existing bituminous roofing
́ Existing synthetic or
bituminous roofing

900_020910_N0150C_2009_en

900_020910_N0085C_1909_en

STANDARD  DETAILS
UTILITY ROOF SYSTEM ́ Concrete Slab ADHERED ROOF SYSTEM – System A
́ S-Felt GK 400, slip- and protection EXISTING SYNTHETIC ROOFING ́ Sarnafil® TG 76 FSA, self-adhered
layer ́ Primer 600 / 780, if required
́ Sarnafil® TG 66 membrane, loose laid ́ New thermal Insulation,
́ New / additional thermal Insulation, mechanically fastened
loose laid ́ Existing synthetic roofing
́ Existing synthetic or
bituminous roofing System B
́ Sarnafil® TG 76 Felt PS, adhered

SUSTAINABLE  SOLUTIONS
́ Sarnacol®-2142 S, Adhesive
900_020910_N0149C_2009_en
́ New thermal Insulation,
mechanically fastened
́ Existing synthetic roofing

Note: In general, it is recommended to remove the existing synthetic or bituminous roofing before installing a new membrane.
900_020910_N0146C_2009_en

154 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 155


APPLICATION INSTRUCTIONS

ROOF REFURBISHMENT

SERVICE  INFORMATION
SYNTHETIC / BITUMINOUS Direct contact between Sarnafil® T roof waterproofing membranes and other roofing
ROOFING SYSTEMS systems must be avoided.

Area dividers
40 mm

≥ 150 mm

PRODUCT  INFORMATION
APPLICATION  INSTRUCTIONS
900_020910_N0151C_2010_en

BITUMINOUS ROOFING SYSTEM Transition to bituminous roofs should be achieved using construction such as raised
kerbs or area dividers.
If such details are not possible, a Sarnafil® T strip can be used for the transition
between Sarnafil® T roof waterproofing membranes and the bituminous roof. Roof
waterproofing membranes in the transition area must be mechanically fastened.
This will prevent any damage or water infiltration that might occur in the old roof
area from affecting the new area.

Transition to bituminous roofing system


6

STANDARD  DETAILS
3

900_020910_N0152C_2010_en

SUSTAINABLE  SOLUTIONS
1 Old bituminous roof 6 S
 arnafil® T (minimum thickness 1.50 mm
2 New vapour control layer (bituminous mem- or two layers) adhered with hot bitumen to
brane), adhered in the transition area old bituminous roof and hot-air welded to
3 New thermal insulation new Sarnafil® T membrane
4 Sarnafil® T fully adhered to the bituminous 7 Bituminous cover strip adhered to the
vapour control layer Sarnafil® T and the old
5 Sarnabar® with Sarnafast® fasteners and bituminous layer
Sarnafil® T Welding Cord

156 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 157


SERVICE  INFORMATION
PRODUCT  INFORMATION
STANDARD DETAILS

APPLICATION  INSTRUCTIONS
DIFFERENT SOLUTIONS AND VARIANTS OVERVIEW160
LAYER DESCRIPTION 162
PARAPET164
ROOF EDGE TERMINATION WITH GUTTER 168
UPSTAND172
SKYLIGHT176
ROOF DRAIN (OUTLET) 180
SCUPPER184
OVERFLOW188
VENT PIPE / POST 192

STANDARD  DETAILS
GUTTER196
MOVEMENT JOINT 198
FALL ARREST ANCHOR 202

SUSTAINABLE  SOLUTIONS
158 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 159
STANDARD DETAILS

OVERVIEW

SERVICE  INFORMATION
PARAPET Mechanically Fastened Roof System OVERFLOW Mechanically Fastened Roof System
Gravel Ballasted Roof System Gravel Ballasted Roof System
Inverted Roof System Inverted Roof System
Utility Roof System Utility Roof System
Green Roof System (Extenisve / Intensive) Green Roof System (Extenisve / Intensive)
Adhered Roof System Adhered Roof System

ROOF EDGE TERMINATION VENT PIPE / POST

PRODUCT  INFORMATION
Mechanically Fastened Roof System Mechanically Fastened Roof System
WITH GUTTER Gravel Ballasted Roof System Gravel Ballasted Roof System
Inverted Roof System Inverted Roof System
Utility Roof System Utility Roof System
Green Roof System (Extenisve / Intensive) Green Roof System (Extenisve / Intensive)
Adhered Roof System Adhered Roof System

UPSTAND Mechanically Fastened Roof System GUTTER Mechanically Fastened Roof System
Gravel Ballasted Roof System Adhered Roof System

APPLICATION  INSTRUCTIONS
Inverted Roof System
Utility Roof System
Green Roof System (Extenisve / Intensive)
Adhered Roof System

SKYLIGHT Mechanically Fastened Roof System MOVEMENT JOINT Mechanically Fastened Roof System
Gravel Ballasted Roof System Gravel Ballasted Roof System
Inverted Roof System Inverted Roof System
Utility Roof System Adhered Roof System
Green Roof System (Extenisve / Intensive)
Adhered Roof System

STANDARD  DETAILS
ROOF DRAIN (OUTLET) Mechanically Fastened Roof System FALL ARREST ANCHOR Mechanically Fastened Roof System
Gravel Ballasted Roof System Gravel Ballasted Roof System
Inverted Roof System Inverted Roof System
Utility Roof System Utility Roof System
Green Roof System (Extenisve / Intensive) Green Roof System (Extenisve / Intensive)
Adhered Roof System Adhered Roof System

SUSTAINABLE  SOLUTIONS
SCUPPER Mechanically Fastened Roof System Legend
Gravel Ballasted Roof System Color of products
Roof waterproofing products Sika delivery program
Inverted Roof System Accessory products Sika delivery program
Utility Roof System Other construction products Different suppliers

Green Roof System (Extenisve / Intensive) DRAWING MUST ALWAYS BE REVIEWED BY A DESIGN SPECIALIST AND IF NECESSARY MODIFIED TO ENSURE SUITABILITY FOR THE SPECIFIC APPLICATION
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
Adhered Roof System normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which
do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior
to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to
our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

160 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 161


STANDARD DETAILS

LAYER DESCRIPTION

SERVICE  INFORMATION
SUBSTRATES Steel Deck INTERMEDIATE LAYERS Slip- and Protection Layer Separation-, Levelling-
and Protection Layer

Concrete / Prefabricated Cementitious Mortar


Protection-, Drainage and Filter Layer Protection-, Drainage and Filter Layer

PRODUCT  INFORMATION
Aerated Concrete Wood Deck
Roof Control System Layer

VAPOUR CONTROL LAYER / Vapour Control Layer / Barrier

APPLICATION  INSTRUCTIONS
BARRIER ROOF WATERPROOFING Membrane Membrane with Felt Backing

ADHESIVE Adhesive
Membrane with Felt Backing Existing Membrane
and Self Adhesive

THERMAL INSULATION Thermal Insulation Extrudet Polystyrene (XPS)

STANDARD  DETAILS
BALLAST Gravel

INTERMEDIATE LAYERS Levelling- and Protection Layer Separation- and Fire Protection Layer

Paving with Support Pads Paving on Screed

SUSTAINABLE  SOLUTIONS
Protection Layer Filter Layer

Green Roof Extensive Green Roof Intensive

162 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 163


STANDARD DETAILS

PARAPET

SERVICE  INFORMATION
001.01.02 – Sarnafil® T Metal Sheet – Adhered on Metal Parapet Element – Mechanically Fastened Roof System

40 mm
Hot-air weld

Sarnafil® S-Sealing Tape 10/10


(if required)
Sarnafil® T Metal Sheet Sarnafil® TG 66 / TS 77 membrane, adhered
(Detail 2)

≥ 150 mm
Metal clip
Hot-air weld

Sarnacol® T-660 adhesive


Sarnafil® TS 77 membrane, mechanically fastened

PRODUCT  INFORMATION
Detail 1
S-Glass Fleece-120 separation layer,
Sarnabar® with Sarnafast® Fasteners and fire protection layer (if required)
Sarnafil® T Welding Cord
Sikatherm® / Sarnatherm®,
Metal flashing thermal insulation

Sarnavap® adhesive tape Sarnavap® vapour control layer


(positioning according to local
climate conditions and regulations)

900_020910_910010102C_1901_en
Detail 2
Detail 1 Sarnafil® T Metal Sheet Fastening
Sarnabar® Perimeter
Securement Vertical (Alternative) m
0m
10

APPLICATION  INSTRUCTIONS
0 mm
10
m m
1 00
m
0m
10

SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010102C_1901_en Sika Services AG


January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.01.02 - Parapet - Sarnafil® T Metal Sheet - Adhered on Metal Parapet Element 8048 Zürich
Sika General Detail. Template for translation.
PLANNING INFORMATION Perimeter flashings are formed using strips of Sarnafil® T membrane. The flashing 020.01.02 – Sarnafil® T Metal Sheet – Adhered on Concrete Parapet – Gravel Ballasted Roof System
Switzerland
Tel: +41 584364040
strips are to be fully adhered with Sarnacol® T-660 adhesive to the substrate and The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
welded to the field sheet. The substrate must be free of ridges, and the flashing
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
40 mm
Hot-air weld Sarnacol® T-660 adhesive
must be attached with a good adhesive bond.
Sarnafil® S-Sealing Tape 10/10
(if required) Sarnafil® TG 66 membrane, adhered
A counter flashing should be installed on utility roof systems to protect the mem-
Sarnafil® T Metal Sheet

≥ 150 mm
brane. (Detail 2) Hot-air weld

STANDARD  DETAILS
Metal clip
The fully adhered flashing strips can be either hot welded to mechanically fastened Sarnafil® TG 66 membrane, loose laid
Sarnafil® T Metal Sheet or to be covered with mechanically fastened metal clip and Protection layer (if required)
Well rounded and washed gravel
metal capping. Detail 1 16/32 mm, min. 50 mm thick and
80 kg/m2
At all upstands and penetrations wider than 50 cm Sarnafil® T membrane must be Sarnabar® with Sarnafast® Fasteners and
Sikatherm® / Sarnatherm®,
Sarnafil® T Welding Cord
secured with Sarnabar® either to the horizontal or vertical surface. thermal insulation
Sarnavap® adhesive tape

Sarnavap® vapour control layer


(positioning according to local
climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
Detail 2
Detail 1 Sarnafil® T Metal Sheet Fastening
Sarnabar® Perimeter 900_020910_910200102C_1901_en
m
Securement Vertical (Alternative) 0m
10
0 mm
10
0 mm
10
m
0m
10

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200102C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.01.02 - Parapet - Sarnafil® T Metal Sheet - Adhered on Concrete Parapet 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
Tel: +41 584364040
164 ROOFING HANDBOOK Sarnafil® T The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
ROOFING HANDBOOK Sarnafil® T 165
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
STANDARD DETAILS

PARAPET

SERVICE  INFORMATION
030.01.04 – Metal Capping – Adhered on Concrete Parapet – Inverted Roof System 050.01.04 – Metal Capping – Adhered on Concrete Parapet – Green Roof System (Extensive / Intensive)

Metal capping Sarnacol® T-660 adhesive Metal capping Sarnacol® T-660 adhesive

Sarnafil® TG 66 membrane, adhered Sarnafil® TG 66 membrane, adhered


Sarnafil® S-Sealing Tape 10/10
(if required)
Sarnafil® S-Sealing Tape 10/10

≥ 150 mm
Paving support pad 1/20 with joint cross Sarnabar® with Sarnafast® Fasteners and
(if required) Sarnafil® T Welding Cord
Metal clip

≥ 150 mm
Paving slabs min. ballast of 12 kg/m2 Metal clip Hot-air weld
for every 10 mm of XPS
Hot-air weld Aquadrain-550 Sarnafil® TG 66 membrane, loose laid

PRODUCT  INFORMATION
drainage, filter and protection layer
S-Felt VS 140 filter layer Soil with plants 50-150 mm thick
Sarnabar® with Sarnafast® Fasteners and Detail 1 and 50-170 kg/m2
Sarnafil® T Welding Cord Thermal insulation XPS
Sarnavap® adhesive tape Sikatherm® / Sarnatherm®,
Detail 1 thermal insulation
Sarnafil® TG 66 membrane, loose laid

Detail 1 Sarnavap® vapour control layer


S-Felt A 300 levelling layer Detail 1
Sarnabar® Perimeter (positioning according to local
Securement Vertical (Alternative) Sarnabar® Perimeter
Securement Vertical (Alternative) climate conditions and regulations)

900_020910_910300104C_1901_en

APPLICATION  INSTRUCTIONS
900_020910_910500104C_1901_en

Roof systems with a


minimum slope of 1,50 %

SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300104C_1901_en Sika Services AG
ON CONCRETE DECK WITH PAVING SLABS January 2019
Tüffenwies 16 SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500104C_1901_en Sika Services AG
January 2019
SF TPO - 030.01.04 - Parapet - Metal Capping - Adhered on Concrete Parapet 8048 Zürich ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Sika General Detail. Template for translation. SF TPO - 050.01.04 - Parapet - Metal Capping - Adhered on Concrete Parapet 8048 Zürich
Switzerland Sika General Detail. Template for translation.
Tel: +41 584364040 Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only

040.01.02 – Metal Capping – Adhered on Concrete Parapet – Utility Roof System 060.01.01 – Sarnafil® T Metal Sheet – Adhered on Concrete Parapet – Adhered Roof
Tel:System
+41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

Metal capping Sarnacol® T-660 adhesive 40 mm


Hot-air weld Sarnacol® T-660 adhesive
Sarnafil® TG 66 membrane, adhered
Sarnafil® S-Sealing Tape 10/10 Sarnafil® S-Sealing Tape 10/10
Sarnafil® TG 66 membrane, adhered
(if required) (if required)
Sarnabar® with Sarnafast® Fasteners and
Metal clip Sarnafil® T Welding Cord Sarnafil® T Metal Sheet

≥ 150 mm
(Detail 2) Hot-air weld

STANDARD  DETAILS
Hot-air weld
≥ 150 mm

Metal clip
Counter flashing ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
Paving Support pad 1/20 with Joint cross
● Sarnafil® TG 76 FSA membrane, self adhered
Detail 1
Sarnafil® TG 66 membrane, loose laid
Protection layer (if required)
Sarnabar® with Sarnafast® Fasteners
Paving slabs min. Ballast of 12 kg/m2 Sikatherm® / Sarnatherm®,
Detail 1 for every 10 mm of thermal insulation thermal insulation
Sarnavap®-5000 E SA vapour barrier,
self adhered SikaRoof® Board Adhesive - beads applied
Sikatherm® / Sarnatherm®,
Sarnavap® adhesive tape thermal insulation
Detail 1
Sarnabar® Perimeter Sarnavap® vapour control layer

SUSTAINABLE  SOLUTIONS
Securement Vertical (Alternative) (positioning according to local Detail 2
climate conditions and regulations) Detail 1 Sarnafil® T Metal Sheet fastening
Sarnabar® Peel Stop Securement 900_020910_910600101C_2102_en
Vertical (Alternative) m
0m
10
0 mm
900_020910_910400102C_1902_en
10
mm
100
m
0m
10

Use appropriate primer to improve


the adhesion on critical substrates
SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400102C_1902_en Sika Services AG
February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16
SF TPO - 040.01.02 - Parapet - Metal Capping - Adhered on Concrete Parapet 8048 Zürich
Sika General Detail. Template for translation.
Switzerland SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600101C_2102_en Sika Services AG
February 2021
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Tel: +41 584364040
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's SF TPO - 060.01.01 - Parapet - Sarnafil® T Metal Sheet - Adhered on Concrete Parapet 8048 Zürich
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com Sika General Detail. Template for translation.
166
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T Switzerland ROOFING HANDBOOK Sarnafil® T 167
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
STANDARD DETAILS

ROOF EDGE TERMINATION


WITH GUTTER

SERVICE  INFORMATION
001.02.02 – Mechanically Fastened Roof System

Sarnafil® TS 77 membrane, cover strip Sarnafil® TS 77 membrane, mechanically fastened

Hot-air weld S-Glass Fleece-120 separation layer,


fire protection layer (if required)

Sarnafil® T Metal Sheet 40 mm Sikatherm® / Sarnatherm®,


(Detail 1) thermal insulation

Sarnafil® S-Sealing Tape 10/10


(if required)

PRODUCT  INFORMATION
Sarnavap® adhesive tape

Detail 1

900_020910_910010201C_1901_en
Sarnafil® T Metal Sheet Fastening
m
0m
10
m Metal flashing
0m
10
m
0m
10 Sarnavap® vapour control layer
m
0m (positioning according to local
10
climate conditions and regulations)

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010201C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.02.01 - Roof Edge Termination with Gutter 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
PLANNING INFORMATION Mechanically fastened, loosely laid or adhered Sarnafil® T roof waterproofing mem- 020.02.01 – Gravel Ballasted Roof System
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

brane hot welded to mechanically fastened Sarnafil® T Metal Sheet.


Sarnafil® T Gravel stop bracket Sarnafil® TG 66 membrane, loose laid
and S-Gravelstop Profile
Sarnafil® T Gravel stop bracket and S-Gravelstop Profile to be installed in combination
with ballasted roof systems. Hot-air weld
Well rounded and washed gravel
16/32 mm, min. 50 mm thick and
Sarnafil® S-Sealing Tape 10/10 80 kg/m2
Protection layer (if required)

STANDARD  DETAILS
Sarnafil® T Metal Sheet
(Detail 1) 40 mm
Sikatherm® / Sarnatherm®,
thermal insulation

Sarnavap® vapour control layer


Sarnavap® adhesive tape (positioning according to local
climate conditions and regulations)
Detail 1
Sarnafil® T Metal Sheet Fastening
m 900_020910_910200201C_2001_en
0m
10
m
0m
10
m
0m

SUSTAINABLE  SOLUTIONS
10
m
0m
10

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200201C_2001_en Sika Services AG


January 2020
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.02.01 - Roof Edge Termination with Gutter 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

168 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 169


STANDARD DETAILS

ROOF EDGE TERMINATION


WITH GUTTER

SERVICE  INFORMATION
030.02.01 – Inverted Roof System 050.02.01 – Green Roof System (Extensive / Intensive)

Paving support pad 1/20 with joint cross Sarnabar® with Sarnafast® Fasteners and Sarnafil® T Gravel stop bracket Sarnafil® TG 66 membrane, loose laid
Sarnafil® T Welding Cord and S-Gravelstop Profile
Sarnafil® T Gravel stop bracket Sarnafil® TG 66 membrane, cover strip Hot-air weld
and S-Gravelstop Profile Soil with plants 50-150 mm thick
Paving slabs min. ballast of 12 kg/m2 and 50-170 kg/m2
Hot-air weld Sarnafil® S-Sealing Tape 10/10
for every 10 mm of XPS
Aquadrain-550
S-Felt VS 140 filter layer drainage, filter and protection layer
Sarnafil® S-Sealing Tape 10/10 Sarnafil® T Metal Sheet
(Detail 1) 40 mm
Thermal insulation XPS Sikatherm® / Sarnatherm®,
Sarnafil® T Metal Sheet thermal insulation
(Detail 2) 40 mm

PRODUCT  INFORMATION
Sarnafil® TG 66 membrane, loose laid
Sarnavap® vapour control layer
Sarnavap® adhesive tape (positioning according to local
S-Felt A 300 levelling layer
climate conditions and regulations)

Detail 1 Detail 1
Sarnafil® T Metal Sheet Fastening
m 900_020910_910500201C_2001_en
0m
10
m
Detail 1 0m
10
900_020910_910300201C_1901_en

Sarnabar® Perimeter m
0m
Detail 2 10
Securement Vertical (Alternative)
Sarnafil® T Metal Sheet Fastening 0 mm Roof systems with a
10 minimum slope of 1,50 %
m
0m
10
0 mm
10

APPLICATION  INSTRUCTIONS
m
0m
10
m
0m
10

SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500201C_2001_en Sika Services AG


January 2020
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 050.02.01 - Roof Edge Termination with Gutter 8048 Zürich
Sika General Detail. Template for translation.
SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300201C_1901_en Sika Services AG Switzerland
January 2019
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16
Tel: +41 584364040
SF TPO - 030.02.01 - Roof Edge Termination with Gutter 8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Sika General Detail. Template for translation. Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
Switzerland
040.02.01 – Utility Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Tel: +41 584364040 060.02.01 – Adhered Roof System
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

Sarnafil® T Gravel stop bracket Sarnafil® TG 66 membrane, loose laid Hot-air weld ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
and S-Gravelstop Profile ● Sarnafil® TG 76 FSA membrane, self adhered

Hot-air weld Sarnafil® S-Sealing Tape 10/10


Paving slabs min. Ballast of 12 kg/m2
for every 10 mm of thermal insulation Sikatherm® / Sarnatherm®,
Sarnafil® S-Sealing Tape 10/10 Sarnafil® T Metal Sheet
(Detail 1) thermal insulation
Protection layer (if required) 40 mm

STANDARD  DETAILS
Sarnafil® T Metal Sheet
(Detail 1) 40 mm Sarnavap®-5000 E SA vapour barrier,
Sikatherm® / Sarnatherm®, self adhered
thermal insulation

Sarnavap® vapour control layer


Sarnavap® adhesive tape SikaRoof® Board Adhesive - beads applied
(positioning according to local Detail 1
climate conditions and regulations) Sarnafil® T Metal Sheet Fastening
m 900_020910_910600201C_2102_en
Detail 1 0m
Paving Support pad 1/20 with Joint cross 10
Sarnafil® T Metal Sheet Fastening 0 mm
m 900_020910_910400201C_1902_en 10
0m m
10 00
m
m 1
0m m
10 0m
10 Use appropriate primer to improve
0 mm
the adhesion on critical substrates

SUSTAINABLE  SOLUTIONS
10
0 mm
10

SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600201C_2102_en Sika Services AG


February 2021
SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400201C_1902_en Sika Services AG ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
February 2019 SF TPO - 060.02.01 - Roof Edge Termination with Gutter 8048 Zürich
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16 Sika General Detail. Template for translation.
SF TPO - 040.02.01 - Roof Edge Termination with Gutter 8048 Zürich Switzerland
Sika General Detail. Template for translation.
Switzerland The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Tel: +41 584364040 Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

170 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 171


STANDARD DETAILS

UPSTAND

SERVICE  INFORMATION
001.03.02 – Sarnafil® T Metal Sheet – Adhered on Metal Wall Element – Mechanically Fastened Roof System

Sarnafil® T Metal Sheet

Sarnaplast®-2235 or Sikaflex®-11 FC sealant


with backing rod and appropriate primer Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord
Sarnacol® T-660 adhesive

≥ 150 mm
Hot-air weld

Sarnafil® TG 66 / TS 77 membrane, adhered Sarnafil® TS 77 membrane, mechanically fastened

Detail 1

PRODUCT  INFORMATION
S-Glass Fleece-120 separation layer,
Metal flashing fire protection layer (if required)
Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® adhesive tape
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)
Detail 1

900_020910_910010302C_1901_en
Sarnabar® Perimeter
Securement Vertical (Alternative)

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010302C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.03.02 - Upstand - Sarnafil® T Metal Sheet - Adhered on Metal Wall Element 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
PLANNING INFORMATION Perimeter flashings are formed using strips of Sarnafil® T membrane. The flashing 020.03.02 – Sarnafil® T Metal Sheet – Adhered on Concrete Wall – Gravel Ballasted Roof System
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

strips are to be fully adhered with Sarnacol® T-660 adhesive to the substrate and
welded to the field sheet. The substrate must be free of ridges, and the flashing Sarnafil® T Metal Sheet
Sarnaplast®-2235 or Sikaflex®-11 FC sealant
must be attached with a good adhesive bond. with backing rod and appropriate primer
Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord
A counter flashing should be installed on utility roof systems to protect the mem- Sarnacol® T-660 adhesive

≥ 150 mm
brane. Hot-air weld

STANDARD  DETAILS
Sarnafil® TG 66 membrane, adhered
Sarnafil® TG 66 membrane, loose laid
The fully adhered flashing strips can be either hot welded to mechanically fastened
Sarnafil® T Metal Sheet or to be covered with mechanically fastened counter flashing. Protection layer (if required)
Top end of Sarnafil® T Metal Sheet or counter flashing to be sealed, using Sarna- Well rounded and washed gravel
plast®-2235 or Sikaflex®-11 FC. Detail 1
16/32 mm, min. 50 mm thick and
80 kg/m2

At all upstands and penetrations wider than 50 cm Sarnafil® T membrane must be Sikatherm® / Sarnatherm®,
Sarnavap® adhesive tape thermal insulation
secured with Sarnabar® either to the horizontal or vertical surface.

Detail 1 Sarnavap® vapour control layer


Sarnabar® Perimeter (positioning according to local
Securement Vertical (Alternative) climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
900_020910_910200302C_1901_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200302C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.03.02 - Upstand - Sarnafil® T Metal Sheet - Adhered on Concrete Wall 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
172 173
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T
STANDARD DETAILS

UPSTAND

SERVICE  INFORMATION
030.03.03 – Counter Flashing – Adhered on Concrete Wall – Inverted Roof System 050.03.03 – Counter Flashing – Adhered on Concrete Wall – Green Roof System (Extensive / Intensive)

Counter flashing Counter flashing


Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant
with backing rod and appropriate primer with backing rod and appropriate primer
Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord
Paving support pad 1/20 with joint cross Sarnacol® T-660 adhesive

≥ 150 mm
Sarnacol® T-660 adhesive

≥ 150 mm
Hot-air weld
Sarnafil® TG 66 membrane, adhered
Sarnafil® TG 66 membrane, loose laid
Sarnafil® TG 66 membrane, adhered Paving slabs min. ballast of 12 kg/m2
for every 10 mm of XPS
Aquadrain-550
drainage, filter and protection layer

PRODUCT  INFORMATION
Soil with plants 50-150 mm thick
Sarnabar® with Sarnafast® Fasteners and and 50-170 kg/m2
Sarnafil® T Welding Cord S-Felt A 300 levelling layer Detail 1

Sikatherm® / Sarnatherm®,
Detail 1 Thermal insulation XPS Sarnavap® adhesive tape thermal insulation

Sarnafil® TG 66 membrane, loose laid Sarnavap® vapour control layer


Detail 1
Sarnabar® Perimeter (positioning according to local
Hot-air weld
S-Felt A 300 levelling layer Securement Vertical (Alternative) climate conditions and regulations)
Detail 1
Sarnabar® Perimeter
Securement Vertical (Alternative)
900_020910_910300303C_1901_en 900_020910_910500303C_1901_en Roof systems with a
minimum slope of 1,50 %

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300303C_1901_en Sika Services AG SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500303C_1901_en Sika Services AG
January 2019
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION January 2019
Tüffenwies 16
SF TPO - 030.03.03 - Upstand - Counter Flashing - Adhered on Concrete Wall 8048 Zürich SF TPO - 050.03.03 - Upstand - Counter Flashing - Adhered on Concrete Wall 8048 Zürich
Sika General Detail. Template for translation. Sika General Detail. Template for translation.
Switzerland Switzerland
Tel: +41 584364040 Tel: +41 584364040
040.03.01 – Counter Flashing – Adhered on Concrete Wall – Utility Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
060.03.01 – Sarnafil® T Metal Sheet – Adhered on Concrete Wall – Adhered Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
www.sika.com
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Counter flashing Sarnafil® T Metal Sheet


Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant
with backing rod and appropriate primer Sarnabar® with Sarnafast® Fasteners and with backing rod and appropriate primer
Sarnafil® T Welding Cord Sarnabar® with Sarnafast® Fasteners
Sarnacol® T-660 adhesive
Hot-air weld Sarnacol® T-660 adhesive
≥ 150 mm

≥ 150 mm
Paving Support pad 1/20 with Joint cross Hot-air weld

STANDARD  DETAILS
Sarnafil® TG 66 membrane, adhered
Sarnafil® TG 66 membrane, adhered
Sarnafil® TG 66 membrane, loose laid
Protection layer (if required) ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
Paving slabs min. Ballast of 12 kg/m2 ● Sarnafil® TG 76 FSA membrane, self adhered
Detail 1
for every 10 mm of thermal insulation
Detail 1

Sikatherm® / Sarnatherm®, Sarnavap®-5000 E SA vapour barrier, Sikatherm® / Sarnatherm®,


Sarnavap® adhesive tape thermal insulation self adhered thermal insulation

Detail 1 Sarnavap® vapour control layer SikaRoof® Board Adhesive - beads applied
Detail 1
Sarnabar® Perimeter (positioning according to local
Sarnabar® Peel Stop
Securement Vertical (Alternative) climate conditions and regulations)
Securement Vertical (Alternative)

SUSTAINABLE  SOLUTIONS
900_020910_910400301C_1902_en 900_020910_910600301C_2102_en

Use appropriate primer to improve


the adhesion on critical substrates

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400301C_1902_en Sika Services AG


SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600301C_2102_en Sika Services AG
February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION February 2021
Tüffenwies 16
SF TPO - 040.03.01 - Upstand - Counter Flashing - Adhered on Metal Wall Element 8048 Zürich SF TPO - 060.03.01 - Upstand - Sarnafil® T Metal Sheet - Adhered on Concrete Wall
Sika General Detail. Template for translation. 8048 Zürich
Switzerland Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
174 175
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T
STANDARD DETAILS

SKYLIGHT

SERVICE  INFORMATION
001.04.02 – Sealed – Adhered on Skylight System – Mechanically Fastened Roof System

Sarnaplast®-2235 or Sikaflex®-11 FC sealant


and appropriate primer
Sarnafil® TG 66 / TS 77 membrane, adhered
Metal termination profile
Sarnabar® with Sarnafast® Fasteners and

≥ 150 mm
Sarnafil® T Welding Cord
Hot-air weld

PRODUCT  INFORMATION
Sarnacol® T-660 adhesive
Sarnafil® TS 77 membrane, mechanically fastened

Sikatherm® / Sarnatherm®, Sarnavap® vapour control layer


thermal insulation (positioning according to local
climate conditions and regulations)

S-Glass Fleece-120 separation layer,


fire protection layer (if required) Sarnavap® adhesive tape
900_020910_910010402C_1901_en

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010402C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.04.02 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

PLANNING INFORMATION Skylight flashings are formed using strips of Sarnafil® T membrane. The flashing 020.04.02 – Sealed – Adhered on Skylight System – Gravel Ballasted Roof System
strips are to be fully adhered with Sarnacol® T-660 adhesive to the substrate and
welded to the field sheet. The substrate must be free of ridges, and the flashing
must be attached with a good adhesive bond.
Sarnaplast®-2235 or Sikaflex®-11 FC sealant
and appropriate primer
A counter flashing should be installed on utility roof systems to protect the mem-
Sarnafil® TG 66 membrane, adhered
brane.

STANDARD  DETAILS
Sarnabar® with Sarnafast® Fasteners and
Metal termination profile
The fully adhered flashing strips to be covered with mechanically fastened metal Sarnafil® T Welding Cord

≥ 150 mm
termination profile. Top end of profile to be sealed, using Sarnaplast®-2235 or Hot-air weld
Sikaflex®-11 FC. Sarnacol® T-660 adhesive
Sarnafil® TG 66 membrane, loose laid

At all upstands and penetrations wider than 50 cm Sarnafil® T membrane must be


Well rounded and washed
secured with Sarnabar® either to the horizontal or vertical surface. gravel 16/32 mm, min. 50 mm
Protection layer (if required) thick and 80 kg/m2
Sarnavap® adhesive tape
Sikatherm® / Sarnatherm®,
thermal insulation

SUSTAINABLE  SOLUTIONS
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

900_020910_910200402C_1901_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200402C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.04.02 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
176 ROOFING HANDBOOK Sarnafil® T the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T 177
STANDARD DETAILS

SKYLIGHT

SERVICE  INFORMATION
030.04.02 – Sealed – Adhered on Skylight System – Inverted Roof System 050.04.02 – Sealed – Adhered on Skylight System – Green Roof System (Extensive / Intensive)

Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant


and appropriate primer and appropriate primer
Sarnafil® TG 66 membrane, adhered

Paving support pad 1/20 with joint cross Sarnabar® with Sarnafast® Fasteners and
Metal termination profile Sarnafil® T Welding Cord Metal termination profile

≥ 150 mm

≥ 150 mm
Hot-air weld

Sarnacol® T-660 adhesive

PRODUCT  INFORMATION
Paving slabs min. ballast of 12 kg/m2 Sarnafil® TG 66 membrane, loose laid
for every 10 mm of XPS
Soil with plants 50-150 mm thick Sarnacol® T-660 adhesive
Sarnafil® TG 66 membrane, and 50-170 kg/m2
adhered
S-Felt VS 140 filter layer Aquadrain-550
drainage, filter and protection layer
Sarnafil® TG 66 membrane,
Thermal insulation XPS loose laid Sikatherm® / Sarnatherm®,
thermal insulation Sarnavap® adhesive tape
S-Felt A 300 levelling layer Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)
Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord

APPLICATION  INSTRUCTIONS
Roof systems with a
minimum slope of 1,50 %
900_020910_910300402C_1901_en 900_020910_910500402C_1901_en

SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300402C_1901_en Sika Services AG SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500402C_1901_en Sika Services AG
January 2018
ON CONCRETE DECK WITH PAVING SLABS January 2019 ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Tüffenwies 16
SF TPO - 050.04.02 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich
SF TPO - 030.04.02 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich Sika General Detail. Template for translation.
Sika General Detail. Template for translation. Switzerland
Switzerland
Tel: +41 584364040
Tel: +41 584364040
040.04.02 – Sealed – Adhered on Skylight System – Utility Roof System 060.04.01 – Sealed – Adhered on Skylight System – Adhered Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant


and appropriate primer and appropriate primer
Sarnafil® TG 66 membrane, adhered Sarnafil® TG 66 membrane, adhered

STANDARD  DETAILS
Sarnabar® with Sarnafast® Fasteners and
Metal termination profile
Sarnafil® T Welding Cord Sarnabar® with Sarnafast® Fasteners
≥ 150 mm

Hot-air weld

≥ 150 mm
Sarnacol® T-660 adhesive Hot-air weld
Sarnafil® TG 66 membrane, loose laid

● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive Sarnacol® T-660 adhesive


Paving slabs min. Ballast of 12 kg/m2 Counter flashing
for every 10 mm of thermal insulation ● Sarnafil® TG 76 FSA membrane, self adhered

Protection layer (if required)


Sarnavap® adhesive tape Sikatherm® / Sarnatherm®,
thermal insulation Sarnavap®-5000 E SA
Sikatherm® / Sarnatherm®,
thermal insulation vapour barrier, self adhered

SUSTAINABLE  SOLUTIONS
Sarnavap® vapour control layer SikaRoof® Board Adhesive -
(positioning according to local beads applied
climate conditions and regulations) Metalclip Termination (Alternative)
Paving Support pad 1/20 with Joint cross

900_020910_910400402C_1902_en Use appropriate primer to improve 900_020910_910600401C_2102_en

the adhesion on critical substrates

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400402C_1902_en Sika Services AG


February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16
SF TPO - 040.04.02 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600401C_2102_en Sika Services AG
February 2021
Sika General Detail. Template for translation. ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Switzerland
SF TPO - 060.04.01 - Skylight - Sealed - Adhered on Skylight System 8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Sika General Detail. Template for translation.
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Switzerland
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
178 ROOFING HANDBOOK Sarnafil® T
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Tel: +41 584364040 ROOFING HANDBOOK Sarnafil® T 179
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
STANDARD DETAILS

ROOF DRAIN (OUTLET)

SERVICE  INFORMATION
001.05.01 – Mechanically Fastened Roof System

Sarnafil® T Drain S-Leafguard

Hot-air weld Sarnafil® TS 77 membrane, mechanically fastened

S-Glass Fleece-120 separation layer,


fire protection layer (if required)

Sikatherm® / Sarnatherm®,

PRODUCT  INFORMATION
thermal insulation

Sarnavap® vapour control layer


(positioning according to local
climate conditions and regulations)

900_020910_910010501C_1901_en

Sarnavap® adhesive tape

Compression ring

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010501C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.05.01 - Roof Drain (Outlet) 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

PLANNING INFORMATION Prefabricated Sarnafil® T Drain to be mechanically fastened to surface. 020.05.01 – Gravel Ballasted Roof System
Mechanically fastened, loosely laid or adhered Sarnafil® T roof waterproofing mem-
brane hot welded to Sarnafil® T Drain. Sarnafil® T Drain S-Leafguard

The S-Leafguard and S-Gravel Frame with S-Grid Square serves as protection against Hot-air weld Sarnafil® TG 66 membrane, loose laid

infiltration of gravel and leaves into the Sarnafil® T Drain.


Well rounded and washed gravel Protection layer (if required)
16/32 mm, min. 50 mm thick and
80 kg/m2

STANDARD  DETAILS
Sikatherm® / Sarnatherm®,
thermal insulation

Sarnavap® vapour control layer


(positioning according to local
climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
900_020910_910200501C_1901_en

Compression ring

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200501C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.05.01 - Roof Drain (Outlet) 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

180 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 181


STANDARD DETAILS

ROOF DRAIN (OUTLET)

SERVICE  INFORMATION
030.05.01 – Inverted Roof System 050.05.01 – Green Roof System (Extensive / Intensive)

Sarnafil® T Drain S-Leafguard Sarnafil® T Drain S-Leafguard

Sarnafil® TG 66 membrane, cover strip Hot-air weld Sarnafil® TG 66 membrane, loose laid
Paving support pad 1/20 with joint cross

Soil with plants 50-150 mm thick Aquadrain-550


Hot-air weld Paving slabs min. ballast of 12 kg/m2 and 50-170 kg/m2 drainage, filter and protection layer
for every 10 mm of XPS

S-Felt VS 140 filter layer

PRODUCT  INFORMATION
Sikatherm® / Sarnatherm®,
Thermal insulation XPS thermal insulation

Sarnafil® TG 66 membrane, Sarnavap® vapour control layer


loose laid (positioning according to local
climate conditions and regulations)
S-Felt A 300 levelling layer

900_020910_910300501C_1901_en 900_020910_910500501C_1901_en Roof systems with a


minimum slope of 1,50 %
Compression ring Compression ring

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300501C_1901_en Sika Services AG SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500501C_1901_en Sika Services AG
January 2019
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION January 2019
Tüffenwies 16
SF TPO - 030.05.01 - Roof Drain (Outlet) 8048 Zürich SF TPO - 050.05.01 - Roof Drain (Outlet) 8048 Zürich
Sika General Detail. Template for translation. Sika General Detail. Template for translation.
Switzerland Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

040.05.01 – Utility Roof System 060.05.01 – Adhered Roof System

Sarnafil® T Drain S-Gravel Frame with S-Grid Square Sarnafil® T Drain S-Leafguard

Hot-air weld Sarnafil® TG 66 membrane, loose laid Hot-air weld


● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S
Paving slabs min. Ballast of 12 kg/m2 Protection layer (if required) adhesive
Sarnafil® TG 66 membrane, loose laid
for every 10 mm of thermal insulation ● Sarnafil® TG 76 FSA membrane, self adhered

STANDARD  DETAILS
Sikatherm® / Sarnatherm®,
thermal insulation

Sikatherm® / Sarnatherm®,
thermal insulation SikaRoof® Board Sarnavap®-5000 E SA vapour barrier,
Adhesive - self adhered
beads applied
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

Paving Support pad 1/20 with 900_020910_910600501C_2102_en

Joint cross
Compression ring

SUSTAINABLE  SOLUTIONS
900_020910_910400501C_1902_en
Use appropriate primer to improve
the adhesion on critical substrates
Compression ring

SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600501C_2102_en Sika Services AG


SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400501C_1902_en Sika Services AG ON CONCRETE DECK WITH THERMAL INSULATION February 2021
Tüffenwies 16
February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16 SF TPO - 060.05.01 - Roof Drain (Outlet) 8048 Zürich
SF TPO - 040.05.01 - Roof Drain (Outlet) 8048 Zürich Sika General Detail. Template for translation.
Sika General Detail. Template for translation. Switzerland
Switzerland Tel: +41 584364040
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
Tel: +41 584364040 applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

182 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 183


STANDARD DETAILS

SCUPPER

SERVICE  INFORMATION
001.06.02 – Adhered on Metal Element – Mechanically Fastened Roof System

Sarnacol® T-660 adhesive

Sarnafil® TG 66 / TS 77 membrane, adhered

S-Leafguard Hot-air weld

Sarnafil® TS 77 membrane, mechanically fastened

Sarnaplast®-2235 or Sikaflex®-11 FC sealant

PRODUCT  INFORMATION
with backing rod and appropriate primer
S-Glass Fleece-120 separation layer,
fire protection layer (if required)
Sarnafil® T Scupper Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local

900_020910_910010602C_1901_en
Sarnavap® adhesive tape climate conditions and regulations)

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010602C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.06.02 - Scupper - Adhered on Metal Element 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
PLANNING INFORMATION Prefabricated Sarnafil® T Scupper to be mechanically fastened to surface. 020.06.02 – Adhered on Concrete Wall – Gravel Ballasted Roof System
Mechanically fastened, loosely laid or adhered Sarnafil® T roof waterproofing mem-
S-Gravel Frame with S-Grid Square
brane and Sarnafi®l T upstand membrane hot welded to Sarnafil® T Scupper.

The S-Leafguard and S-Gravel Frame with S-Grid Square serves as protection against Sarnacol® T-660 adhesive Hot-air weld
infiltration of gravel and leaves into the Sarnafil® T Scupper.
Well rounded and washed gravel
Sarnafil® TG 66 membrane, adhered 16/32 mm, min. 50 mm thick and

STANDARD  DETAILS
80 kg/m2

Protection layer (if required)


Sarnaplast®-2235 or Sikaflex®-11 FC sealant
with backing rod and appropriate primer
Sarnafil® TG 66 membrane, loose laid

Sarnafil® T Scupper
Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
Sarnavap® adhesive tape (positioning according to local
climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
900_020910_910200602C_1901_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200602C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.06.02 - Scupper - Adhered on Concrete Wall 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

184 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 185


STANDARD DETAILS

SCUPPER

SERVICE  INFORMATION
030.06.02 – Adhered on Concrete Wall – Inverted Roof System 050.06.02 – Adhered on Concrete Wall – Green Roof System (Extensive / Intensive)

Hot-air weld S-Leafguard

Sarnafil® TG 66 membrane, loose laid Sarnacol® T-660 adhesive Hot-air weld

Sarnacol® T-660 adhesive Paving support pad 1/20 with joint cross
Soil with plants 50-150 mm thick
Sarnafil® TG 66 membrane, adhered and 50-170 kg/m2
2
Sarnafil® TG 66 membrane, adhered Paving slabs min. ballast of 12 kg/m
for every 10 mm of XPS
Aquadrain-550
S-Felt VS 140 filter layer drainage, filter and protection layer
S-Leafguard Sarnaplast®-2235 or Sikaflex®-11 FC sealant

PRODUCT  INFORMATION
with backing rod and appropriate primer
Sarnaplast®-2235 or Sikaflex®-11 FC sealant Thermal insulation XPS Sarnafil® TG 66 membrane, loose laid
with backing rod and appropriate primer
Sarnafil® T Scupper
Sarnafil® T Scupper S-Felt A 300 levelling layer Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
Sarnavap® adhesive tape (positioning according to local
climate conditions and regulations)

900_020910_910300602C_1901_en

Roof systems with a


minimum slope of 1,50 % 900_020910_910500602C_1901_en

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500602C_1901_en Sika Services AG
January 2019
SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300602C_1901_en Sika Services AG ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
ON CONCRETE DECK WITH PAVING SLABS January 2019 SF TPO - 050.06.02 - Scupper - Adhered on Concrete Wall 8048 Zürich
Tüffenwies 16
Sika General Detail. Template for translation.
SF TPO - 030.06.02 - Scupper - Adhered on Concrete Wall 8048 Zürich Switzerland
Sika General Detail. Template for translation.
Switzerland The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
040.06.02 – Adhered on Concrete Wall – Utility Roof System 060.06.01 – Adhered on Concrete Wall – Adhered Roof System
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

S-Gravel Frame with S-Grid Square


Counter flashing

Hot-air weld Sarnacol® T-660 adhesive S-Leafguard

Sarnacol® T-660 adhesive


Paving slabs min. Ballast of 12 kg/m2
Hot-air weld
for every 10 mm of thermal insulation Sarnafil® TG 66 membrane, adhered

STANDARD  DETAILS
Sarnafil® TG 66 membrane, adhered
Protection layer (if required)
● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S
Sarnaplast®-2235 or Sikaflex®-11 FC sealant with adhesive
Sarnaplast®-2235 or Sikaflex®-11 FC sealant
backing rod and appropriate primer ● Sarnafil® TG 76 FSA membrane, self adhered
with backing rod and appropriate primer
Sarnafil® TG 66 membrane,
Sarnafil® T Scupper loose laid
Sarnafil® T Scupper Sikatherm® / Sarnatherm®,
Sikatherm® / Sarnatherm®, thermal insulation
thermal insulation
Sarnavap® adhesive tape
Sarnavap® vapour control layer SikaRoof® Board Adhesive -
(positioning according to local Sarnavap®-5000 E SA vapour barrier, self adhered beads applied
climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
Paving Support pad 1/20
with Joint cross

900_020910_910400602C_1902_en 900_020910_910600601C_2102_en

Use appropriate primer to improve


the adhesion on critical substrates

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400602C_1902_en Sika Services AG


February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16
SF TPO - 040.06.02 - Scupper - Adhered on Concrete Wall SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600601C_2102_en Sika Services AG
8048 Zürich February 2021
Sika General Detail. Template for translation. ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Switzerland SF TPO - 060.06.01 - Scupper - Adhered on Concrete Wall 8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Sika General Detail. Template for translation.
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Switzerland
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
186 ROOFING HANDBOOK Sarnafil® T
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
ROOFING HANDBOOK Sarnafil® T 187
STANDARD DETAILS

OVERFLOW

SERVICE  INFORMATION
001.07.02 – Adhered on Metal Element – Mechanically Fastened Roof System

Sarnacol® T-660 adhesive


Sarnafil® TG 66 / TS 77 membrane, adhered

Hot-air weld
Sarnaplast®-2235 or Sikaflex®-11 FC sealant
with backing rod and appropriate primer
Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord

Sarnafil® T Overflow Hot-air weld

PRODUCT  INFORMATION
Sarnafil® TS 77 membrane, mechanically fastened
Detail 1

S-Glass Fleece-120 separation layer,


Sarnavap® adhesive tape fire protection layer (if required)
Sikatherm® / Sarnatherm®,
Detail 1 thermal insulation
Sarnabar® Perimeter Sarnavap® vapour control layer
Securement Vertical (Alternative) (positioning according to local

900_020910_910010702C_1901_en
climate conditions and regulations)

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010702C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.07.02 - Overflow - Adhered on Metal Element 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
PLANNING INFORMATION Prefabricated Sarnafil® T Overflow to be mechanically fastened to upstand structure. 020.07.02 – Adhered on Concrete Wall – Gravel Ballasted Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
Sarnafil® T upstand membrane hot welded to Sarnafil® T Overflow.
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

Sarnacol® T-660 adhesive Sarnafil® TG 66 membrane, adhered

Hot-air weld
Sarnaplast®-2235 or Sikaflex®-11 FC sealant
with backing rod and appropriate primer

STANDARD  DETAILS
Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord
Sarnafil® T Overflow
Hot-air weld

Well rounded and washed gravel Protection layer (if required)


16/32 mm, min. 50 mm thick and 80 kg/m2

Detail 1

Sarnafil® TG 66 membrane, loose laid


Sarnavap® adhesive tape
Sikatherm® / Sarnatherm®,
thermal insulation

SUSTAINABLE  SOLUTIONS
Detail 1
Sarnabar® Perimeter Sarnavap® vapour control layer
Securement Vertical (Alternative) (positioning according to local
climate conditions and regulations)

900_020910_910200702C_1901_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200702C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.07.02 - Overflow - Adhered on Concrete Wall 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
188 ROOFING HANDBOOK Sarnafil® T
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com ROOFING HANDBOOK Sarnafil® T 189
STANDARD DETAILS

OVERFLOW

SERVICE  INFORMATION
030.07.02 – Adhered on Concrete Wall – Inverted Roof System 050.07.02 – Adhered on Concrete Wall – Green Roof System (Extensive / Intensive)

Sarnafil® TG 66 membrane, adhered Sarnacol® T-660 adhesive Sarnafil® TG 66 membrane, adhered

Hot-air weld
Hot-air weld
Sarnabar® with Sarnafast® Fasteners and Sarnaplast®-2235 or Sikaflex®-11 FC sealant
Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnafil® T Welding Cord with backing rod and appropriate primer
with backing rod and appropriate primer Sarnabar® with Sarnafast® Fasteners and
Paving support pad 1/20 with joint cross Sarnafil® T Welding Cord
Sarnafil® T Overflow
Hot-air weld
Sarnafil® T Overflow Hot-air weld

PRODUCT  INFORMATION
Soil with plants 50-150 mm thick Aquadrain-550
Paving slabs min. ballast of 12 kg/m2
and 50-170 kg/m2 drainage, filter and protection layer
for every 10 mm of XPS
Sarnacol® T-660 adhesive
Detail 1
S-Felt VS 140 filter layer Sarnafil® TG 66 membrane, loose laid
Detail 1 Sarnavap® adhesive tape
Thermal insulation XPS Sikatherm® / Sarnatherm®,
Detail 1 thermal insulation
Detail 1
Sarnabar® Perimeter S-Felt A 300 levelling layer Sarnabar® Perimeter Sarnavap® vapour control layer
Securement Vertical (Alternative) Securement Vertical (Alternative) (positioning according to local
climate conditions and regulations)
Sarnafil® TG 66 membrane,
loose laid

APPLICATION  INSTRUCTIONS
900_020910_910300702C_1901_en 900_020910_910500702C_1901_en

Roof systems with a


minimum slope of 1,50 %

SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500702C_1901_en Sika Services AG


SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300702C_1901_en Sika Services AG January 2019
January 2019 ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16 SF TPO - 050.07.02 - Overflow - Adhered on Concrete Wall
SF TPO - 030.07.02 - Overflow - Adhered on Concrete Wall 8048 Zürich
8048 Zürich Sika General Detail. Template for translation.
Sika General Detail. Template for translation. Switzerland
040.07.02 – Adhered on Concrete Wall – Utility Roof System Switzerland 060.07.01 – Adhered on Concrete Wall – Adhered Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sarnacol® T-660 adhesive Sarnafil® TG 66 membrane, adhered Sarnacol® T-660 adhesive Sarnafil® TG 66 membrane, adhered

Hot-air weld
Sarnaplast®-2235 or Sikaflex®-11 FC sealant Hot-air weld
with backing rod and appropriate primer Sarnaplast®-2235 or Sikaflex®-11 FC sealant

STANDARD  DETAILS
Sarnabar® with Sarnafast® Fasteners and with backing rod and appropriate primer
Sarnafil® T Welding Cord
Sarnafil® T Overflow Sarnabar® with Sarnafast® Fasteners
Hot-air weld
Sarnafil® T Overflow
Counter flashing Protection layer (if required) Hot-air weld

Paving slabs min. Ballast of 12 kg/m2 Detail 1 ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
Detail 1
for every 10 mm of thermal insulation ● Sarnafil® TG 76 FSA membrane, self adhered
Sarnafil® TG 66 membrane, loose laid
Sarnavap® adhesive tape Sarnavap®-5000 E SA vapour barrier, self adhered
Sikatherm® / Sarnatherm®,
Sikatherm® / Sarnatherm®, thermal insulation
thermal insulation

SUSTAINABLE  SOLUTIONS
Detail 1
Sarnabar® Perimeter Sarnavap® vapour control layer SikaRoof® Board Adhesive -
Securement Vertical (Alternative) Detail 1
(positioning according to local beads applied
Sarnabar® peel stop
climate conditions and regulations)
securement vertical (alternative)
Paving Support pad 1/20 with
Joint cross
900_020910_910400702C_1902_en 900_020910_910600701C_2102_en

Use appropriate primer to improve


the adhesion on critical substrates

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400702C_1902_en Sika Services AG


February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16
SF TPO - 040.07.02 - Overflow - Adhered on Concrete Wall SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600701C_2102_en Sika Services AG
8048 Zürich February 2021
Sika General Detail. Template for translation. ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
Switzerland SF TPO - 060.07.01 - Overflow - Adhered on Concrete Wall 8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Sika General Detail. Template for translation.
Switzerland
190 191
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
ROOFING HANDBOOK Sarnafil® T
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com ROOFING HANDBOOK Sarnafil® T
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com
STANDARD DETAILS

VENT PIPE / POST

SERVICE  INFORMATION
001.08.01 – Mechanically Fastened Roof System

Sarnaplast®-2235 or Sikaflex®-11 FC sealant


and appropriate primer Stainless steel jubilee clip / shrinking hose
Hot-air weld
Sarnafil® T Pipe / Post Flashing
Sarnafil® TS 77 membrane, mechanically
fastened Point fastening with Sarnafast® Washers and Fasteners

PRODUCT  INFORMATION
S-Glass Fleece-120 separation layer,
fire protection layer (if required)
Point fastening of
Sikatherm® / Sarnatherm®,
vent pipe / post flashing

900_020910_910010801C_1901_en
thermal insulation
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

Sarnavap® adhesive tape

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010801C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.08.01 - Vent Pipe / Post 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

PLANNING INFORMATION On vent pipe / post flashing Sarnafil® TS roof waterproofing for mechanically 020.08.01 – Gravel Ballasted Roof System
fastened roof systems to be point fastened using four Sarnafast® Washers and
Fasteners. In all other ballasted / adhered roof systems, no additional fastening
to be needed. Sarnaplast®-2235 or Sikaflex®-11 FC sealant
and appropriate primer Stainless steel jubilee clip / shrinking hose
Hot-air weld
Sarnafil® T Pipe / Post Flashing to be hot welded to Sarnafil® T roof waterproofing Sarnafil® T Pipe / Post Flashing
membrane. Sarnafil® TG 66 membrane, loose laid
Well rounded and washed gravel

STANDARD  DETAILS
16/32 mm, min. 50 mm thick and
Top end of Sarnafil® T Pipe / Post Flashing to be waterproofed using shrinking hose 80 kg/m2
or stainless steel jubilee clip in combination with Sarnaplast®-2235 or Sikaflex®-11 FC
sealant.

Protection layer (if required)

Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)
Sarnavap® adhesive tape

SUSTAINABLE  SOLUTIONS
900_020910_910200801C_1901_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910200801C_1901_en Sika Services AG


January 2019
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.08.01 - Vent Pipe / Post 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

192 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 193


STANDARD DETAILS

VENT PIPE / POST

SERVICE  INFORMATION
030.08.01 – Inverted Roof System 050.08.01 – Green Roof System (Extensive / Intensive)

Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant


and appropriate primer Stainless steel jubilee clip / shrinking hose and appropriate primer Stainless steel jubilee clip / shrinking hose

Hot-air weld Hot-air weld


Sarnafil® T Pipe / Post Flashing Sarnafil® T Pipe / Post flashing
Sarnafil® TG 66 membrane, loose laid
Sarnafil® TG 66 membrane, loose laid Paving support pad 1/20 with joint cross Soil with plants 50-150 mm thick
and 50-170 kg/m2
Paving slabs min. ballast
of 12 kg/m2 for every 10 mm
of XPS

PRODUCT  INFORMATION
S-Felt VS 140 filter layer Aquadrain-550
drainage, filter and protection
layer
Thermal insulation XPS Sikatherm® / Sarnatherm®,
thermal insulation
S-Felt A 300 levelling layer Sarnavap® vapour control layer
(positioning according to
local climate conditions and
Sarnavap® adhesive tape regulations)

900_020910_910300801C_1901_en 900_020910_910500801C_1901_en Roof systems with a


minimum slope of 1,50 %

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910300801C_1901_en Sika Services AG SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910500801C_1901_en Sika Services AG
January 2019 January 2019
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 030.08.01 - Vent Pipe / Post 8048 Zürich SF TPO - 050.08.01 - Vent Pipe / Post 8048 Zürich
Sika General Detail. Template for translation. Sika General Detail. Template for translation.
Switzerland Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com
040.08.01 – Utility Roof System
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
060.08.01 – Adhered Roof System
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Sarnaplast®-2235 or Sikaflex®-11 FC sealant Sarnaplast®-2235 or Sikaflex®-11 FC sealant


with backing rod and appropriate primer with backing rod and appropriate primer Stainless steel jubilee clip / shrinking hose
Hot-air weld Sarnafil® T Pipe / Post Flashing

Sarnafil® TG 66 membrane, loose laid Stainless steel jubilee clip Hot-air weld Sarnafil® T Pipe / Post Flashing

STANDARD  DETAILS
Paving slabs min. Ballast of 12 kg/m2 Counter flashing
for every 10 mm of thermal insulation
● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S
adhesive
● Sarnafil® TG 76 FSA membrane, self adhered

Protection layer (if required)


Sikatherm® / Sarnatherm®,
thermal insulation
Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control SikaRoof® Board Adhesive - Sarnavap®-5000 E SA
layer (positioning according beads applied vapour barrier, self adhered
to local climate conditions
Sarnavap® adhesive tape

SUSTAINABLE  SOLUTIONS
and regulations)

Paving Support pad 1/20


with Joint cross
900_020910_910400801C_1902_en 900_020910_910600801C_2102_en

Use appropriate primer to improve


the adhesion on critical substrates

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910400801C_1902_en Sika Services AG


February 2019
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16
SF TPO - 040.08.01 - Vent Pipe / Post 8048 Zürich SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600801C_2102_en Sika Services AG
February 2021
Sika General Detail. Template for translation.
Switzerland ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 060.08.01 - Vent Pipe / Post 8048 Zürich
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 Sika General Detail. Template for translation.
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com Switzerland
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's

194 ROOFING HANDBOOK Sarnafil® T Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com ROOFING HANDBOOK Sarnafil® T 195
STANDARD DETAILS

GUTTER

SERVICE  INFORMATION
001.09.01 – Mechanically Fastened Roof System

Sarnafil® TS 77 membrane, mechanically fastened Sarnafil® TS 77 membrane, mechanically fastened

S-Glass Fleece-120 separation layer, Hot-air weld


fire protection layer (if required)
Sikatherm® / Sarnatherm®, Spot fastening with Sarnafast®
thermal insulation Washers and Fasteners
Sarnavap® vapour control Metal flashing
layer (positioning according
to local climate conditions
and regulations)

PRODUCT  INFORMATION
900_020910_910010901C_1901_en

APPLICATION  INSTRUCTIONS
Sarnafil® TS 77 membrane, cover strip Sarnabar® with Sarnafast®Fasteners

SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910010901C_1901_en Sika Services AG


January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.09.01 - Gutter 8048 Zürich
Sika General Detail. Template for translation.
Switzerland

PLANNING INFORMATION Gutter edges on top of thermal insulation should be protected with metal flashing. 060.09.01 – Adhered Roof System
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Tel: +41 584364040
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

Sarnafil® T roof waterproofing membrane must be secured with either Sarnabar® or


Sarnafil® TG 66 membrane, adhered ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
Sarnafast® Washers and Fasteners. ● Sarnafil® TG 76 FSA membrane, self adhered
Sikatherm® / Sarnatherm®, Hot-air weld
Mechanically fastened gutter flashing, using Sarnafil® TS membrane and Sarnabar® thermal insulation
with Sarnafast® Fasteners securement along vertical areas. SikaRoof® Board Adhesive - Sarnabar® with Sarnafast®
beads applied Fasteners

STANDARD  DETAILS
Adhered gutter flashing, using Sarnacol® T-660 adhesive and Sarnafil® TG 66 mem- Metal flashing
brane along vertical areas. Depending on the width of gutter Sarnafil TG 76 mem-
brane secured with Sarnabar® and Sarnafast® Fasteners along vertical areas.

Sarnavap®-5000 E SA
vapour barrier, self adhered

Sarnacol® T-660 adhesive

SUSTAINABLE  SOLUTIONS
Sarnabar® with Sarnafast® Fasteners

Use appropriate primer to improve


the adhesion on critical substrates
900_020910_910600901C_2102_en

SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910600901C_2102_en Sika Services AG


February 2021
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 060.09.01 - Gutter
196 ROOFING HANDBOOK Sarnafil® T Sika General Detail. Template for translation.
8048 Zürich
ROOFING HANDBOOK Sarnafil® T 197
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
STANDARD DETAILS

MOVEMENT JOINT

SERVICE  INFORMATION
001.10.01 – Mechanically Fastened Roof System

Sarnabar® with Sarnafast® Fasteners and Sarnafil® TS 77 membrane, cover strip


Sarnafil® T Welding Cord
Hot-air weld Expanded polyethylene rod

Sarnafil® TS 77 membrane, mechanically fastened Metal flashing

S-Glass Fleece-120 separation layer,


fire protection layer (if required)

PRODUCT  INFORMATION
Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

Vapour control layer with


900_020910_910011001C_1901_en
expansion loop

APPLICATION  INSTRUCTIONS
SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910011001C_1901_en Sika Services AG
January 2019
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.10.01 - Movement Joint 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

PLANNING INFORMATION Sarnavap® vapour control layer to be installed with an expansion loop above metal 020.10.01 – Gravel Ballasted Roof System
flashing.
Hot-air weld Sarnabar® with Sarnafast® Fasteners and
Sarnafil® T Welding Cord
Sarnafil® T membrane must be secured with Sarnabar® and Sarnafast® Fastener on
both sides of movement joints. Sarnafil® T Gravel stop bracket Sarnafil® TG 66 membrane, cover strip
and S-Gravelstop Profile

Sarnafil® T Gravel stop bracket and S-Gravelstop Profile to be installed in combination Sarnafil® TG 66 membrane, loose laid Expanded polyethylene rod
with ballasted roof systems.

STANDARD  DETAILS
Well rounded and washed gravel Metal flashing
16/32 mm, min. 50 mm thick and
Installation of expanded polyethylene rod and waterproof with Sarnafil® T coverstrip, 80 kg/m2
hot welded on both sides of movement joints to roof waterproofing membrane.
Protection layer (if required)

Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

SUSTAINABLE  SOLUTIONS
Vapour control layer with
expansion loop 900_020910_910201001C_2001_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910201001C_2001_en Sika Services AG


January 2020
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.10.01 - Movement Joint 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

198 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 199


STANDARD DETAILS

MOVEMENT JOINT

SERVICE  INFORMATION
030.10.01 – Inverted Roof System 060.10.01 – Adhered Roof System

Paving support pad 1/20 with joint cross ● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive Expanded polyethylene rod
● Sarnafil® TG 76 FSA membrane, self adhered
Paving slabs min. ballast of 12 kg/m2
Sarnabar® with Sarnafast® Fasteners Metal flashing
for every 10 mm of XPS
S-Felt VS 140 filter layer
Hot-air weld Sarnafil® TG 66 membrane, cover strip

Thermal insulation XPS


Hot-air weld

Sarnafil® TG 66 membrane, loose laid

PRODUCT  INFORMATION
S-Felt A 300 levelling layer

Hot-air weld 900_020910_910301001C_1901_en Sikatherm® / Sarnatherm®,


thermal insulation
Sarnabar® with Sarnafast® Fasteners and Expanded polyethylene rod
Sarnafil® T Welding Cord
Metal flashing Sarnafil® TG 66 membrane, cover strip

Vapour control layer with


expansion loop 900_020910_910601001C_2102_en

Use appropriate primer to improve


the adhesion on critical substrates SikaRoof® Board Adhesive - beads applied

APPLICATION  INSTRUCTIONS
Sarnavap®-5000 E SA vapour barrier, self adhered

SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910301001C_1901_en Sika Services AG
January 2019
ON CONCRETE DECK WITH PAVING SLABS Tüffenwies 16
SF TPO - 030.10.01 - Movement Joint 8048 Zürich
Sika General Detail. Template for translation.
Switzerland SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910601001C_2102_en Sika Services AG
February 2021
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 060.10.01 - Movement Joint
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
200 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 201
STANDARD DETAILS

FALL ARREST ANCHOR

SERVICE  INFORMATION
001.11.01 – ABS Point – Uninsulated – Mechanically Fastened Roof System

Sarnaplast®-2235 or Sikaflex®-11 FC sealant ABS Point


and appropriate primer
(only in combination with stainless steel jubilee clip) Stainless steel jubilee clip / shrinking hose

Sarnafil® T Point Flashing

≥ 150 mm
Hot-air weld

PRODUCT  INFORMATION
Sarnafil® TS 77 membrane, mechanically fastened

S-Glass Fleece-120 separation layer,


fire protection layer (if required)
Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)

900_020910_910011101C_2003_en

Point fastening according to

APPLICATION  INSTRUCTIONS
supplier application manual

SARNAFIL® TPO - MECHANICALLY FASTENED ROOF SYSTEM 900_020910_910011101C_2003_en Sika Services AG


March 2020
ON METAL DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 001.11.01 - Fall Arrest Anchor - ABS Point - Uninsulated 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
www.sika.com
PLANNING INFORMATION Depending on the use ABS Point or Seculine Vario Post to be installed according to 020.11.02 – Seculine Vario – Insulated – Gravel Ballasted Roof System
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

supplier application manual.

Uninsulated Sarnafil® T Point or Seculine Vario Flashing to be hot welded to Seculine Vario Post
Sarnafil® T roof waterproofing membrane.
Sarnafil® T Seculine Vario seal set
Top end of Sarnafil® T Point or Seculine Vario Flashing to be waterproofed using
Hot-air weld

≥ 200 mm
shrinking hose or stainless steel jubilee clip in combination with Sarnaplast®-2235 or

STANDARD  DETAILS
Sikaflex®-11 FC sealant. Sarnafil® TG 66 membrane, loose laid

Insulated Seculine Vario Post to be waterproofed using Sarnafil® T Seculine Vario seal Well rounded and washed gravel
16/32 mm, min. 50 mm thick and
set. 80 kg/m2

Protection layer (if required)

Sikatherm® / Sarnatherm®,
thermal insulation
Sarnavap® vapour control layer
(positioning according to local

SUSTAINABLE  SOLUTIONS
climate conditions and regulations)
Point fastening according to
supplier application manual

900_020910_910201102C_2003_en

SARNAFIL® TPO - GRAVEL BALLASTED ROOF SYSTEM 900_020910_910201102C_2003_en Sika Services AG


March 2020
ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 020.11.02 - Fall Arrest Anchor - Seculine Vario - Insulated 8048 Zürich
Sika General Detail. Template for translation.
Switzerland
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

202 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 203


STANDARD DETAILS

FALL ARREST ANCHOR

SERVICE  INFORMATION
030.11.03 – Seculine Vario – Uninsulated – Inverted Roof System 050.11.02 – Seculine Vario – Insulated – Green Roof System (Extensive / Intensive)

Sarnaplast®-2235 or Sikaflex®-11 FC sealant Seculine Vario Post


and appropriate primer
(only in combination with stainless steel jubilee clip) Stainless steel jubilee clip / shrinking hose Sarnafil® TG 66 membrane, loose laid Seculine Vario Post

≥ 200 mm
Hot-air weld Sarnafil® T Seculine Vario Flashing Aquadrain-550 S-Seculine Vario seal set PVC

≥ 150 mm
drainage, filter and protection layer
Sarnafil® TG 66 membrane, loose laid Paving support pad 1/20 with joint cross Hot-air weld

PRODUCT  INFORMATION
Paving slabs min. ballast of 12 kg/m2
for every 10 mm of XPS Soil with plants 50-150 mm thick
and 50-170 kg/m2
S-Felt VS 140 filter layer S-Glass Fleece-120 separation layer
(if required)
Thermal insulation XPS Sikatherm® / Sarnatherm®,
thermal insulation
S-Felt A 300 levelling layer Sarnavap® vapour control layer
(positioning according to local
climate conditions and regulations)
Point fastening according to
supplier application manual Point fastening according to
supplier application manual

APPLICATION  INSTRUCTIONS
900_020910_910301103C_2003_en 900_020910_910501102C_2003_en

SARNAFIL® TPO - INVERTED ROOF SYSTEM, LOOSE LAID MEMBRANE 900_020910_910301103C_2003_en Sika Services AG SARNAFIL® TPO - GREEN ROOF SYSTEM - EXTENSIVE 900_020910_910501102C_2003_en Sika Services AG
March 2020
ON CONCRETE DECK WITH PAVING SLABS March 2020
Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION Tüffenwies 16
SF TPO - 030.11.03 - Fall Arrest Anchor - Seculine Vario - Uninsulated SF TPO - 050.11.02 - Fall Arrest Anchor - Seculine Vario - Insulated 8048 Zürich
8048 Zürich Sika General Detail. Template for translation.
Sika General Detail. Template for translation.
Switzerland Switzerland

The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040 The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
www.sika.com
040.11.01 – ABS Point – Uninsulated – Utility Roof System www.sika.com
060.11.03 – Seculine Vario – Uninsulated – Adhered Roof System
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Stainless steel ear

Sarnaplast®-2235 or Sikaflex®-11 FC sealant ABS Point Sarnaplast®-2235 or Sikaflex®-11 FC sealant Seculine Vario anchor
and appropriate primer and appropriate primer
(only in combination with stainless steel jubilee clip) Stainless steel jubilee clip / shrinking hose (only in combination with stainless steel jubilee clip) Stainless steel jubilee clip / shrinking hose

STANDARD  DETAILS
Sarnafil® TG 66 membrane, loose laid S-Secupoint Flashing PVC Sarnafil® T Seculine Vario Flashing
≥ 150 mm

≥ 150 mm
Paving slabs min. Ballast of 12 kg/m2 Hot-air weld Hot-air weld
for every 10 mm of thermal insulation
● Sarnafil® TG 76 Felt PS membrane, Sarnacol®-2142 S adhesive
Protection layer (if required) ● Sarnafil® TG 76 FSA membrane, self adhered

S-Glass Fleece-120 separation layer,


fire protection layer (if required)
Sikatherm® / Sarnatherm®,
Sikatherm® / Sarnatherm®, thermal insulation
thermal insulation
Sarnavap® vapour control layer SikaRoof® Board Sarnavap®-5000 E SA vapour barrier,
(positioning according to local Adhesive - beads applied self adhered

SUSTAINABLE  SOLUTIONS
climate conditions and regulations)
Point fastening according to Point fastening according to
supplier application manual supplier application manual
900_020910_910401101C_2003_en
900_020910_910601103C_2102_en

SARNAFIL® TPO - UTILITY ROOF SYSTEM 900_020910_910401101C_2003_en Sika Services AG


SARNAFIL® TPO - ADHERED ROOF SYSTEM 900_020910_910601103C_2102_en Sika Services AG
March 2020
ON CONCRETE DECK WITH THERMAL INSULATION AND PAVING SLABS Tüffenwies 16 ON CONCRETE DECK WITH THERMAL INSULATION February 2021
Tüffenwies 16
SF TPO - 040.11.01 - Fall Arrest Anchor - ABS Point - Uninsulated 8048 Zürich SF TPO - 060.11.03 - Fall Arrest Anchor - Seculine Vario - Uninsulated
Sika General Detail. Template for translation. 8048 Zürich
Switzerland Sika General Detail. Template for translation.
Switzerland
Tel: +41 584364040
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only
applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. The information only Tel: +41 584364040
Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to www.sika.com applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application, such as changes in substrates etc., or in case of a different application, consult Sika's
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to
the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
www.sika.com

204 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 205


SERVICE  INFORMATION
PRODUCT  INFORMATION
APPLICATION  INSTRUCTIONS
SUSTAINABLE SOLUTIONS
RESPONSIBLE FOR THE FUTURE – SIKA ROOFING SOLUTIONS 208
MORE VALUE LESS IMPACT  209

STANDARD  DETAILS
THE SIKA LIFE CYCLE APPROACH 210
THE SIKA LIFE CYCLE APPROACH FOR ROOFING SYSTEMS 211
SIKA INITIATIVES 212
SUSTAINABILITY PERFORMANCE CONFIRMED BY EPD AND LCA 216
CONTRIBUTING TO GREEN BUILDING CERTIFICATION PROGRAMS 217

SUSTAINABLE  SOLUTIONS
SUSTAINABLE SOLUTIONS SUSTAINABLE SOLUTIONS

RESPONSIBLE FOR THE FUTURE – MORE VALUE LESS IMPACT


SIKA ROOFING SOLUTIONS

SERVICE  INFORMATION
PRODUCT  INFORMATION
APPLICATION  INSTRUCTION
HOW CAN SIKA ROOFING SYSTEMS CONTRIBUTE TO SUSTAINABLE CONSTRUCTION?
Long-lasting, high-performance roofing systems can make a major contribution to sustainable construction. Raw materials,
production, application, the use phase and maintenance have significant influence on the overall sustainability performance of
roofing applications. The contribution of roofing systems to sustainable construction is evaluated from a life-cycle perspective
and evidenced through the various reference projects presented in this brochure.

RAW MATERIALS AND PRODUCTION USE AND MAINTENANCE


Energy and resource efficiency: Sika provides roofing systems Saving energy: Sika solar reflective membranes help save
that use less energy and resources in comparison with com- energy by increasing the reflectivity and as a consequence
petitive technologies. reducing the cooling energy demand of buildings.
Climate change and a growing population require cleaner energy and better-functioning cities. These
forces are driving the demand for intelligent construction materials and smart mobility systems to Climate protection: Sika provides roofing systems with low Saving energy: Sika roofing systems can save energy by
global warming potential. This means a reduced carbon foot- incorporating high-performance thermal insulation.
ease congestion and reduce CO2 emissions. print.

STANDARD  DETAILS
Generating energy: Sika SolaRoof® systems allow the produc-
Sustainability is an important component of Sika’s growth strategy and a clear focus in product APPLICATION tion of energy, while Sika solar reflective membranes improve
development. The ambition of Sika product engineers: to extend the service life of buildings and Air quality: Sika provides low-VOC and VOC-free roofing solu- photovoltaic panel efficiency.
tions that help reduce summer smog and improve health and
industrial applications in order to reduce maintenance effort, to improve energy and material safety conditions during the roof installation process. The low- Improving the microclimate: Sika green roofing systems help
efficiency, and to further enhance user-friendliness and health and safety profiles. odor performance of Sika products has been externally tested improve the microclimate and mitigate the development of
and certified. urban heat islands as well as help manage water runoff from
Sika strives to create more value for all its stakeholders with its products, systems and solutions roofs.
along the entire value chain and throughout the life span of its products. Performance is the DURABILITY
The durability of building materials is a key to sustainable Extending service life: Sika roof refurbishment solutions allow
foundation of sustainability.

SUSTAINABLE  SOLUTIONS
building construction. Internal and external studies document extending the service life of existing roofs by using the existing
the outstanding service life of Sarnafil® roofing systems. buildup as a base for the new system.
Sika roofing solutions take less from the environment and offer more in durability and longevity, A flat roof, using the proper materials and installed by profes-
which results in a smaller overall environmental footprint. sionals, is tight for the lifetime. However, if unpredictable me-
chanical influence occurs, for example subsequent application
of ballast such as green roof, it can lead to unintended leaks
in the waterproofing layer. As a solution SikaRoof® Control Sys-
tem provides security for investors and building owners.

ROOFING HANDBOOK Sarnafil® T 209


SUSTAINABLE SOLUTIONS SUSTAINABLE SOLUTIONS

THE SIKA LIFE CYCLE APPROACH THE SIKA LIFE CYCLE APPROACH
FOR ROOFING SYSTEMS

SERVICE  INFORMATION
What is Life Cycle Assessment (LCA) and why is it Which life cycle phases are included in the sika LCAs?
relevant?
Life Cycle Assessment (LCA) is a standardized
method to assess and compare the inputs, outputs
and potential environmental impacts of products and
services over their life cycle. LCAs are increasingly
Natural Resources Raw Materials Produ
recognized as the best way to evaluate the sustain- c ti
ability performance of construction products and o

n
systems. Cradle to Gate

What impact categories and resources indicators Cradle to Grave

Application

PRODUCT  INFORMATION
are included in an LCA?
There are several impact categories and resource
indicators which can be assessed according to Stan-
dard EN 15804 “Sustainability of construction works
– Environmental product declarations – Core rules
for the product category of construction products.” ce
For roofing the most relevant impact categories and an
Waste End-of-Life Use and M a i nten
resource indicators are the following:

Global Warming Potential


Global warming potential (GWP) [kg CO -eq.]
²

APPLICATION  INSTRUCTION
(“carbon footprint”) is the potential contribution to
climate change due to greenhouse gas emissions. “Cradle to gate” What is included in Sika roofing LCAs? Who prepares and reviews Sika roofing LCAs?
In the “cradle to gate” approach, the LCA investigates the potential envi- The LCA results given in this brochure refer to 1 m² of the Sika roofing LCAs are created internally by the Sika Corporate
Cumulative Energy Demand ronmental impact of a product from raw material extraction to finished roofing system and are based on either the cradle to gate or Product Sustainability Group, using state-of-the-art GaBi soft-
Cumulative energy demand (CED) [MJ] (“energy foot- production. the cradle to grave approach1). ware from thinkstep. The LCA model used has been reviewed
print”) is the total amount of primary energy from by the leading independent research institute Swiss Federal
renewable and non-renewable resources. “Cradle to grave” Which life cycle phases are most relevant for roofing? Laboratories for Materials Science and Technology (EMPA).
In the “cradle to grave” approach, the LCA investigates the potential envi- From a cradle to gate perspective, the majority of the potential
Photochemical Ozone Creation Potential ronmental impact of a product from raw material extraction, production, impacts are related to the raw materials (A) used to produce What are the Sika sustainable roofing solutions?
Photochemical ozone creation potential (POCP) application and use to final disposal at the end of life. (B) the roof waterproofing layer and the other roofing system Sika evaluates its roofing products and systems systematically
[kg C²H4-eq.] (“summer smog”) is the formation components. with regard to environmental impact and contributions to sus-
of reactive chemical compounds, e.g., ozone, from tainable construction based on regular and fully comprehensive
direct sunlight on certain primary air pollutants, From a cradle to grave perspective, the use phase (D) and the Life Cycle Assessments.
which may be harmful to human health, ecosystems end-of-life phase (E) have the most significant influence on
and crops. the overall sustainability performance of roofing applications, What are the Sika sustainable solutions?
due to their contributions to save and / or create energy, to Air quality and emissions

STANDARD  DETAILS
On what standards are Sika LCAs based? avoid carbon emissions and to save resources at the end of life. Roofing products that promote good air quality and minimize
Sika carries out LCAs according to the ISO 14040 The leverage of all of these potential benefits is long-lasting emissions.
series and the Standard EN 15804. The impact functionality and durability.
assessment methodology used is CML 2001. Energy
Roofing products that promote energy efficiency principles.
Where does the Sika LCA data come from?
The data for Sika LCAs is based on public databases, Climate
such as those from ecoinvent, the European Refer- Roofing products that minimize the impact on the climate.
ence Life Cycle Database (ELCD) and thinkstep-GaBi, A
Cradle to Gate B
plus specific data from Sika plants and products. Resources

SUSTAINABLE  SOLUTIONS
Cradle to Grave Efficient use of precious resources.

E D

1) In the LCAs, neither the roof construction (steel deck, concrete deck, soil, plants, etc.) nor capital goods (e.g. machinery) are considered.

210 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 211


SUSTAINABLE SOLUTIONS

SIKA INITIATIVES

SERVICE  INFORMATION
PRODUCT  INFORMATION
SIKA HIGH-PERFORMANCE THERMAL INSULATION Sika SolaRoof® SYSTEMS FOR SOLAR ROOFTOP APPLICATIONS
Thermal insulation is a key to creating a comfortable environment inside a building and it is also a key to saving energy. The The great opportunity, of using flat rooftops for solar applications was recognized early by Sika. The first photovoltaic (PV) instal-
importance of insulation has increased along with continuously evolving insulation standards worldwide, which place higher and lations on Sarnafil® membranes date back to 2004. Several development steps led to the current Sika® SolarMount-1 (SSM1)

APPLICATION  INSTRUCTION
higher demands on the thermal resistance of buildings in order to reduce energy demand for heating and cooling. Sika provides a system. SSM1 requires no roof penetrations but is hot-air welded to the Sika membrane, which prevents lateral movement of the
wide range of thermal insulation materials specially designed and manufactured for optimal performance as part of Sika roof- PV plant on the roof over time. The PV panels on SSM1 can be oriented south or east-west with same SSM1 components.
ing systems. For example, Sikatherm® PIR thermal insulation board is known for low thermal conductivity, low density and good
compressive strength. Most boards are coated with an aluminium, glass tissue or paper facer, which prevents outgassing effects. Sika maintains its own solar parks in several locations to:
́ Monitor the energy yield of different PV technologies
́ Collect first-hand experience with long-term performance
́ Showcase the flexibility of Sika roofing solutions for PV applications

STANDARD  DETAILS
SUSTAINABLE  SOLUTIONS
SIKA TAKES SOLAR REFLECTIVITY TO A NEW LEVEL A NATURAL HABITAT ON YOUR ROOF
The benefits of solar-reflective materials and colors are well known and understood, especially in warm climates around the world. The addition of a green roof to an otherwise unused area of a building is beneficial for the surrounding environment and can also
With urban density increasing, the heat-island effect impacts cities at an ever increasing rate. White highly reflective thermo- contribute to your green building certification rating. Green roofs are great insulators and can significantly lower a building’s cool-
plastic increase reflectance and reduce both the heat-island effect and the cooling energy consumption of buildings. Sika roofing ing energy consumption and costs. Furthermore, green roofs filter air by absorbing and converting carbon dioxide to oxygen.
systems support LEED Green Building certification by providing a very high initial Solar Reflectance Index (SRI) and high 3-year Sika green roofing systems help improve the microclimate, mitigate the development of urban heat islands and help mange water
SRI values according to CRRC (Cool Roof Rating Council) and ECRC (European Cool Roof Council) standard procedures. runoff from roofs.

212 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 213


SUSTAINABLE SOLUTIONS

SIKA INITIATIVES

SERVICE  INFORMATION
PRODUCT  INFORMATION
SIKA’S ROOFING SYSTEMS ARE DESIGNED TO LAST THE SIKA RESPONSIBILITY FOR HEALTH & ENVIRONMENT
Proven performance over time is perhaps the signature attribute of Sika roofing systems, which are also known for effective Sika is a responsible company that takes health & safety seriously
watertightness, energy efficiency and minimal environmental impact. This longevity under real-world conditions is proven around The application method is very important for roof areas requiring torch-free membranes such as timber roof decks or timber

APPLICATION  INSTRUCTION
the world, for all construction types and in all types of climates. upstands, timber fillets, hanging tiles, thatched roofs, roof light kerbs and upstands, cladding, lantern roof lights, confined spaces
The roof of the First United Methodist Church in Gilford, NH (USA) has two unique features. The first is obvious – it has a very and window sills. Particular attention should be given to concealed flammable materials where there is the potential for flames
distinctive, sweeping shape known as the hyperbolic paraboloid. The second characteristic is not so apparent – installed in 1976, to travel and ignite particles in inaccessible areas. For all these cases, Sika Roofing systems specially engineered for “no flame”
this roof was one of the very first Sika single-ply membrane installations in North America. It replaced a failing roof buildup that applications are available and completely free of such risks.
was only a few years old. The roof is still in place today, periodically maintained and in good condition.
Health & safety during application
Sika roofing systems are all designed for outdoor application and comply with the latest health & safety regulations1). Indepen-
dent studies confirm that the exposure to solvents during application remains well below allowed workplace exposure levels.
The use of Sika solutions containing VOCs (volatile organic compounds) is therefore safe when carried out in accordance with the
materials application guidelines and the product data sheets2).

Low-VOC and VOC-free roofing solutions


Sika provides intelligent solutions, using the most advanced technologies. Sika has developed low-VOC and VOC-free roofing
systems (e.g. Sarnacol® for adhered roofing systems)for markets and customers who want to avoid products containing such
solvents.

STANDARD  DETAILS
1)  Exceptions may apply. Please contact your local Sika organization.
2) Local health and safety regulations must be followed. For further information please contact your local Sika organization.

SUSTAINABLE  SOLUTIONS
MINIMIZING SITE WASTE IN ROOF REFURBISHMENT
Upgrading the thermal performance of existing buildings is an ideal way to save energy and comply with UK building regulations.
A thermal upgrade can be easily achieved by installing additional insulation over the existing substrate and covering it with a Sika
roofing system. By using the existing buildup as a base for the new system, the client benefits from:

́ Reduced carbon costs of the roofing system


́ Reduced waste because the existing system remains in situ and need not be removed (stripped out)
́ Minimal disruption to the operation of the building during installation
́ A cost-effective method of increasing the design life of the building’s roofing system

214 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 215


SUSTAINABLE SOLUTIONS SUSTAINABLE SOLUTIONS

SUSTAINABILITY PERFORMANCE CONTRIBUTING TO GREEN BUILDING


CONFIRMED BY EPD AND LCA CERTIFICATION PROGRAMS

SERVICE  INFORMATION
PRODUCT  INFORMATION
APPLICATION  INSTRUCTION
Interest in Environmental Product Declarations (EPD)s has grown dramatically since recent versions of the U.S. Green Building Over the recent years, several countries and organizations have developed environmental certification programs for buildings. The
Council’s (USGBC) Leadership in Energy and Environmental Design (LEED) program and the UK’s British Research Establishment criteria of the programs are similar, whereas the evaluation may differ substantially. Green building certification programs focus
Environmental Assessment Method (BREEAM) award credits for buildings incorporating products with EPD, which provide added on assessing whole buildings or building products. Sika is actively involved in all major green building programs around the world.
value and comprehensive information for assessing buildings and other structures. Most relevant from the global perspective are LEED, BREEAM and DGNB.
Sika provides custom Life Cycle Assessment (LCA) calculations, Environmental Product Declarations (EPD) and project specific
reports developed with internal tools. LEED (Leadership in Energy and Environmental Design)
The EPDs are a standardized way to communicate relevant environmental information of products by quantifying the environ- LEED is the world’s best known and largest “green building” certification system. It was developed in 2000 by the U.S. Green
mental aspects and potential environmental impacts throughout the product’s life cycle based on quantitative data from LCA. Building Council (USGBC) and is most relevant for North America but is also heavily used in many other regions around the world,
such as South America, Europe and Asia. It is based on a set of rating categories in which specific topics are assessed. The prod-
ucts environmental impact is determined by using LCAs and EPDs.

BREEAM (BRE Environmental Assessment Method)


ENVIRONMENTAL PRODUCT DECLARATION
as per ISO 14025 and EN 15804+A1
BREEAM is an environmental assessment method and rating system for buildings launched in 1990 by the BRE (UK). Local adap-
tations are also used in other countries such as the Netherlands, Sweden and Spain. BREEAM assesses the overall performance
Owner of the Declaration Sika Services AG
Programme holder Institut Bauen und Umwelt e.V. (IBU)
Publisher Institut Bauen und Umwelt e.V. (IBU)
Statement of Verification
Declaration number EPD-SIK-20200030-IBA1-EN BREG EN EPD No.: 000066 Issue 02

of buildings using factors such as energy and water use, the internal environment (health and wellbeing), pollution, transport,

STANDARD  DETAILS
ECO EPD Ref. No. ECO-00001259 ECO EPD Ref. No. 000227
Issue date 17/06/2020 This is to verify that the
Valid to 16/06/2025 Environmental Product Declaration
provided by:

materials etc., awarding credits in each area according to defined performance criteria. The products environmental impact is
Sarnafil® AT
Sika Services AG Sika Ltd.
is in accordance with the requirements of:

determined using LCAs and EPDs.


EN 15804:2012+A1:2013
and
BRE Global Scheme Document SD207

This declaration is for:


www.ibu-epd.com | https://epd-online.com Sarnafil G410 EL

DGNB (Deutsches Gütesiegel für Nachhaltiges Bauen)


Com pany Address
Watchmead
Welwyn Garden City
AL7 1BQ

The DGNB certification system was developed by the German Sustainable Building Council and the German government in 2009.
The system is used in Germany and internationally. DGNB is based on up to 50 criteria in six quality sections, including Environ-
Signed for BRE Global Ltd

27 February 2017
Emma Baker
Operator
24 September 2020
Date of this Issue

23 September 2025
mental Quality, Economic Quality and Technical Quality. For the Environmental Quality section, LCA data and EPDs are used.
Date of First Issue Expiry Date

This Statement of Verification is issued subject to terms and conditions (for


details visit www.greenbooklive.com/terms.

MORE VALUE – GREEN BUILDING CONTRIBUTION


To check the validity of this statement of verification please, visit
www.greenbooklive.com/check or contact us.
BRE Global Ltd., Garston, Watford WD25 9XX.
T: +44 (0)333 321 8811 F: +44 (0)1923 664603 E: Enquiries@breglobal.com

Umwelt Produktdeklaration Name des Herstellers – Name des Produkts BF1805-C-ECOP Rev 0.1 Page 1 of 14 © BRE Global Ltd, 2017

Relevant Sika contributions are as follows:

SUSTAINABLE  SOLUTIONS
In Europe and in the USA, Sika has published product-specific LEED® BREEAM® DGNB
EPDs for all its major roofing membrane brands and tech- LEED® v4 BREEAM® UK-NC 2018 DGNB 2018
nologies. The EPDs conform to the EN 15804 and ISO 14025 SSc 5: Heat island reduction – Mat01: Life cycle impacts ENV1.1: Building Life Cycle A
­ ssessment
standards and are externally verified by the IBU (DE), BRE (UK) traffic white (RAL 9016) Mat03: Responsible sourcing of materials ENV1.2: Local environmental impact
MRc 2: Building disclosure – EPD Mat04: Insulation SOC1.6: Indoor and Outdoor quality
and ASTM International (USA). For further information on EPDs
MRc 3: Building disclosure – Wst01: Construction waste management TEC1.6: Ease of recovery and recycling
please contact your local Sika organization. sourcing of raw materials
MRc 4: Building disclosure – material ingredients
MRc 5: Construction and demolition
waste management

216 ROOFING HANDBOOK Sarnafil® T ROOFING HANDBOOK Sarnafil® T 217


Disclaimer
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in
good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site
conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out
of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from
any other advice offered. The user of the product must test the product’s suitability for the intended application and purpose.
Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders
are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local
Product Data Sheet for the product concerned, copies of which will be supplied on request.

218 ROOFING HANDBOOK Sarnafil® T


ALSO AVAILABLE FROM SIKA
Durability of Sarnafil® T
Polymeric Roofing Membrane
December 2014

Summary report
from Expert report 80740 dated 05 August 2014

Author

ROOFING
Institut für Bautenschutz, Baustoffe und Bauphysik
Dr. Rieche und Dr. Schürger GmbH & Co. KG, 70736 Fellbach, Germany

SUSTAINABLE SOLUTIONS
MORE VALUE LESS IMPACT

Publisher
Sika Services AG and Sika Technology AG, 6060 Sarnen, Switzerland

ApplicAtion MAnuAl
Sarnafil® tG/tS – Sarnafil® G/S

ROOFING
Sarnafil® TG 76 FSA
SELF ADHERED ROOFING SYSTEM FOR FLAT ROOFS

ROOFING ROOFING
GREEN ROOF SOLUTIONS THERMAL INSULATION
WITH Sarnafil® WITH Sikatherm PIR BOARDS
FOR FLAT ROOFING APPLICATIONS

FOR MORE SIKA ROOFING INFORMATION

WE ARE SIKA
Sika is a specialty chemicals company with a leading position in the
development and production of systems and products for bonding,
sealing, damping, reinforcing and protecting in the building sector
and the motor vehicle industry. Sika's product lines feature concrete
admixtures, mortars, sealants and adhesives, structural strengthening
systems, flooring as well as roofing and waterproofing systems.

© SIKA SERVICES AG / ROOFING / ROOFING HANDBOOK Sarnafil ® T / 05.2021

Our most current General Sales Conditions shall apply. Please


consult the most current local Product Data Sheet prior to any use.

SIKA SERVICES AG Contact


Tueffenwies 16 Phone +41 58 436 40 40
CH-8048 Zurich www.sika.com
Switzerland

You might also like