Best Rolling Door NOA 100psf

You might also like

Download as pdf
Download as pdf
You are on page 1of 6
MIAMI MIAMLDADE COUNTY oni PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES 11805 SW 26 Steet, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Mian, Florida 33175-2474 ‘T(TR6) 315.2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) pwn miamidadegoviecanamy Best Rolling Door, MFG 9780 NW 79" Avenue ‘Hialeah Gardens, FL 33016 Score: ‘This NOA is being issued under the applicable rules and regulations governing the use of construction materials, ‘The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (At). ‘This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHI (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and. the AHJ may immediately revoke, modify, or suspend the use of sich product or material within their jurisdiction, RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or ‘material fails to mect the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code, DESCRIPTION: Model S10-100 Steet Roll-up Door APPROVAL DOCUMENT: Drawing No. 100_2009_01, titled “Model $10-100”, sheets 1 through 3 of 3, dated March 25, 2009, last revision dated April 18, 2014, prepared by Best Rolling Door, MFG, signed & sealed by Joseph H. Dixon, Jr, P.E., on May 03, 2014 bearing the Dade County Product Control Renewal stamp with the Notice of Acceptance number & the expiration date by the Miami-Dade County Product Control Section, MissiLe IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Produet Control Approved", unless otherwise noted herei RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this produet. TERMINATION of this NOA will ocour after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature, If any portion of the NOA is displayed, then it shall be done in its entirety, INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors. and shall be available for inspection atthe job site at the request of the Building Offical. ‘This NOA revises & renews NOA # 11-0921.13 and consists of this page 1, evidence submitted pages E-I & E-2 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. NOA No. 14-0514.06 Expiration Date: 06/10/2019 ‘Approval Date: 06/12/2014 Page 1 iar nn Best Rolling Door, 2 A NOTICE OF ACCEPTANC. EVIDENCE SUBMITTED EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 09-0415,09 DRAWINGS 1. Drawing No. 100_2009_01, titled “Model $10-100", sheets 1 through 3 of 3, dated 03/25/09, prepared by Best Rolling Door, Inc, signed and sealed by Joseph H. Dixon, Jr, PE TESTS 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyelie Wind Pressure Loading per FBC, TAS 203-94 4) Tensile Test per ASTM A370, Along with marked-up drawings and installation diagram of Model $10-100 Steel Garage Doors, prepared by Fenestration Testing Laboratory, Inc,, Test Report No. FTL # 5370, dated 03/13/08, signed and sealed by Carlos S. Rionda, P.B. CALCULATIONS 1 Caleulations for attachment of "C” channel guide to steel or conerete jamb, dated 03/21/09, prepared, signed and sealed by Joseph H. Dixon, Jr, P.E. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 07-1107.08, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 02/28/08 and expiring on OI I/!2. STATEMENTS 1, Statement letter of code conformance, dated 03/30/09, signed and sealed by Joseph H. Dixon, Jr, PE, 2. Statement letter of no financial interest, dated 03/20/09, signed and sealed by Joseph H, Dixon, Jr., P.E. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 11-0921.13 DRAWINGS 1. Drawing No, 100_2009_01, titled “Model 810-100”, sheets 1 through 3 of 3, dated March 25, 2009, prepared by Best Rolling Door, Inc, signed and sealed by Joseph H. Dixon, Jr., P.E., on May 22, 2012. Expiration Date: 06/10/2019 Approval Date: 06/12/2014 Best Rolling Door, MF; D B. >Y Noth ACCEPTANCE: EVIDENCE SUBMITTED, TESTS 1 None. CALCULATIONS 1 None. QUALITY ASSURANCE, 1. By Miami-Dade County Department of Regulatory and Economic Resources. MATERIAL CERTIFICATIONS 1. None, STATEMENTS 1. Statement letter of code conformance, dated 08/29/11, signed and sealed by Joseph H. Dixon, Jr., P.E, NEW EVIDENCE SUBMITTED DRAWINGS 1. Drawing No. 100_2009_01, titled “Model $10-100”, sheets I through 3 of 3, dated March 25, 2009, last revision dated April 18, 2014, prepared by Best Rolling Door, MFG, signed & sealed by Joseph H. Dixon, Jr., P.E., on May 03, 2014. TESTS L None. CALCULATIONS L None. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources, MATERIAL CERTIFICATIONS 1 None. STATEMENTS 1. Statement letter of FBC, 2010 code conformance, dated 05/03/14, signed and sealed by Joseph H. Dixon, Jr, PE, Approval Date: 06/12/2014 E-2 is eta) +] wsracnoraue enn le COILSIDE ELEVATION SIDE ELEVATION osatpellag ale . WINDLOCKs - DETAIL) “oxooure or PLAIN INSULATED FLAT SLAT-DETAIL (3) GUIDE RAIL Bottom star ELEVATION - DETAIL(1) etary Oy hy, Nort H Dik Mn, PRODUCT RENEWED S Wy“, teammates Batu facet Stine Misaibotrck ewaniounarenn, stonad) GENERAL NOTES: {+ THE ROLL-UP DOOR SHOWIN ON THIS PRODUCT APPROVAL DOCUMENT. HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2010 EDITION OF THE FLORIDA BUILDING CODE, REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED AS PER SECTION 1600 & 1620 USING Risk CATEGORY II WITH AN ULTIMATE DESIGN WIND SPEED OF 176 MPH, ‘THE ROLL-UP DOOR'S ADEQUACY FOR WIND PREGSURE INPAOT AND FATIGUE RESISTANCE HAS BEEN VERIFIED IN ACCORDANCE WATH THE 2010 TEST PROTOCOLS FOR HIGH ‘VELOCITY HURRICANE ZONES, TAS-201, TAS202 & TAS-208, ALLOWABLE DESIGN PRESSURE RATING: +100.0, -100.0 PSF 2-SLAT TOBE AS.TM. A969 GR 80 STRUCTURAL QUALITY STEEL WITH MIN, FY = 60 KSI ‘AND G.90 GALVANIZING PER A.8.1.N. A869, OR ALS! 304 SERIES STAINLESS STEEL MANUFACTURED VATH AMINIMUM YIELD STRENGTH OF FY = 60 KGL 8. WINOLOCKS 11 GAPLATEO STEEL, ASTM ASOT 4- ALL RIVETS TO BE ALS. 1025 STEEL, CADMIUM PLATED, STAINLESS STEEL CR ZNO PLATED Wi F¥e 37,000 PSI. {-INGULATION MATERIAL GHALL BE EPS-EXPANOED POLYSTYRENE INSULATION MANUFACTURED BY DYPLAST PRODUCTS LLC COMPANY, DADE COUNTY NOTICE OF ‘ACCEPTANCE # 11.0826.07, {6-DOOR MAY BE INSTALLED ON THE INSIDE OR OUTSIDE OF AN EXTERIOR WALL. DOOR IMPACTED ON BOTH SIDE. ‘7-GUIDE DETAILS CAN BE USED IN ANY COMBINATION. 6 CONTRAGTOR TO BE RESPONSIBLE FOR THE SELECTION, PURCHASE AND INSTALLATION ‘OF THIS PRODUGT BASED ON THIS PRODUCT APPROVAL, DOCUMENT. THE CONTRACTOR ‘SHALL ENSURE THAT THE WALL CAN SUPPORT THE JANB FORCES INDICATE ON THIS DOCUMENT. CONSTRUCTION SAFETY AT SITES THE CONTRACTOR'S RESPONSIAIITY, BOTTOM SLAT BOTTOM SLAT ~ DETAIL @ ENG, NAME: JOSEPH H. DIKON JR, PE, FLT Model $10-100 —> KG 'W'""°"°=E8| DADE COUNTY APPROVAL ‘2049 Florida Bullding Code ROLLING STSELDOOR 04 12" (+100/-100 PSF) BEST ROLLING DOOR, MFG 9760 NY, 78h AVENUE HIALEAH GARDENS, FLORIOA 22018 PH 906-008-9860 FAK: 305-696-3552 wazbostdoonus DRAWN No 100_2008.04 SHEET 1 OF 3 DRAWNBY BD, DATE, onze REV. oaert4 EXISTING STEEL STRUCT nee a8 We" oS SHE SHT. 3 Vx Vx and Vy Forces SEEGHT.S Somer 1) ar ‘START @ 7" FROM BOTTOM ‘CHANNEL GUIDE (Cont) SEE SHT.6 >—L212%x3%__Cont, (oLoce ar EVERY OTHER SLATINGLUDNG BOTTOM SLAT ORS ‘STEEL JAMB'E* 30° 4-1/2" w 26'-0" CHANNEL GUIDE-DETAIL 5 Min. Yield Strength = 30,000 psi 20'-0" 16'30" (© ebinan eget HILTI KWIK BOLT 3 ANCHOR SEE ANCHOR SCHEDULE EXISTING POURED CONCRETE REQUIRED 4000 pain, ENG, NAME: JOSEPH H, DIXON IR. PE. recep SEE SHT. 3 ", DADE COUNTY APPROVAL FL7Z06 ‘START @5" FROM BOTTOM 7 ri 2013 Florida Bulding Code Gower vos ee eee WHNDLOCK AT EVERY OTHER (0, 7768 si vr (H0n400PSF) FOR SUP -SUATINGLUDING BOTTOM SLAT. cuuce No , a Lidf f. STATE OF wie Cot % MASONRY JAM “2* DRAWN No BEST ROLLING DOOR, MFG ppaway 9760 NAV. 7a AVENUE. ae 100_2009_01 HIALEAH GARDENS, FLORIDA 39016 DATE Pr: so56083550 FAs sosetbss2 owzar00 SHEET 2 OF 8 REV. 0410/14 SUMMARY OF ANCHORAGE CALCULATIONS Best Rolling Doors 18 gage sat, 0.0831" fins Los 4 10 Slip Loin} 1,50 In 180 in ‘ey | ancHoRs 10 cononeTe Aue FIELD WELD TO STEE!. JAMB. WALLANGLE THICKNESS Catenary Foree 4000 ps 6160 Fy 6D Positive Wind, Pipe 2is7plt | sésnpir | sia3 pit | 6964 pit Wall Angle f9\gmb | —____ Ghana 6d | "thro Negative Wind, Phot ast pit | 36s8plt | sisspir | 696apir Hv Bons ee ea Woll Anglo Gnannot a Bute | 2.0us6 Vacand Vy Rorces Pastive Wind, Vx 2670 pit | 3528 pir | sors pit | s799pir a i eribednon x opciog to. sem Wall Angie, seed fn Negativo Wind, Vi 2eropit | 3828 pit | $035 pi | 6799 pIr rau gai pace : : Poshive Wind, Vy asapit | iooaptt | t2sapir | ts23—ir pete eee eee Qiuen | geen” be in vse ptt | loos pit | t2se pir | 1523 pI¢ CGulde, welded Me Kee @ Tos, sordia.xane | Stale. x91" Blecuode ype 7x B70xx 70x E10xx Oowwor @ewor A Weld, sue i wall angle, Outstanding teg on Wl doer si sat sian sia rx 6-172'@ 10-102" 08. t Mire0 x36" Weld type plug, plug lug, plop, @ tos, Weld thickness wie" ane" ane" sne* Spacing taro, | wre | ote | Tos a . - ~ B. Betd wall angle to Jamb Mr xGH2'@ Moe, sara xaies | in xa18 Hote diameter sre" 518° si" 3/8” Biro. moo, Weld plug, (plug plug. plog, Weald thickness ane" ae a6" ane" Spacing tanec. | 9toc | ontoe. | aroe. \ C-Gulde, concrete anchors ' Concrete strona, fe 4000 psi | 4000pet | 4000p | 4000 xt ' Pogtive Wind i ‘anchor tenslon, PIZCp sero pit | 2204pir | oad pit | istonit \ ssompression, F22Cp s75 pi | liepit | ssunir Tpit i shear, FXZCp aerope | 3528 pit | s03s pit | 679 pir } Negative Wind anchor tnslon, PIZC a2 pi | wosspir | i348 pir | 2000 pir ‘compression, F22Cn 1375 pit | 2069 pif | 2802 pI | 3613 pif shear, F9ZCH zsropit | 3828pir_ | sos pir | G7v9 pit f ENO. NAME: JOSEPH H. IKON JR PE, Type anchor, Hilt Kwik Bolt | Kwik Bolt 9 | Kwik Bolt 3 | Kwik Bolt DADE COUNTY APPROVAL Fries Diss : & “ a“ GE Tenover lorda Bulding Code eabedment 7 %" fe ie FROLUNG STEEL DOOR Spacing toa, | iontee | 700, | shoe. nate (osnorey Model $10-100 we fa eh nite ts BEST ROLLING DOOR, MFG. brawny DRAWN No 9780 Nt Tn AVENUE 400,2009.01 HALENI GARDENS, FLORIDA 23018, pare oe PH 305-6683880 FAX: 3086969552 wage SHEET 3 OFS ‘wheats REV, o4ert4

You might also like