Turbine: Buckets, 1st Stage

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

g INSPECTION REPORT

Gas Turbine Maintenance Turbine


MS 3002, 5002 Buckets, 1st Stage
Date Turbine S/N Prepared by
FSR # Sketches Enclosed? Photos Enclosed?
Data Type
Part Number Out
Part Number In

BUCKET S/N & POSITION Tip


Serial number from bottom of bucket (if available) and (T)
position of bucket in wheel.

CRACKS A C E
Trailing L
State if crack is: J G Leading Trailing
AX - AXIAL RD - RADIAL Edge Edge
Edge
Use letters to indicate crack location and give length of (T/E) (L/E) (T/E)
crack. (V) D (V)
(V) B F
M K H
TIP RUBS
Indicate tip rub severity as:
N - Normal L - Light Bucket
M - Moderate H - Heavy Platform Root
(P) (R)
EROSION / CORROSION
(V) Dovetail
Enter dimension from tip to edge of corrosion. Use
letters to indicate principle zone affected by corrosion. (V)
Enter Height, width, & estimated depth of corrosion /
erosion spot. Suction Side Short Shank Pressure Side
FOREIGN OBJECT DAMAGE
Use letters to indicate location of damage.
CR - Cracked M - Missing Metal
P - Punctured BT - Bent
T - Torn Shank
(Q)

DISPOSITION CODES Dovetail


N - No repair or replacement necessary. (V)
RG - Repaired by GE (a)
RC - Repaired by Customer Long Shank
RO - Repaired by Other (b)
RN - Replaced with new component. SHANK CONFIGURATION
RR - Replacement Recommended
Short Shank
Long Shank (a)
Long Shank (b)

NOTE: Attach lab analysis of deposit and/or corrosion material to report.

Comments:

GT9000 Sheet: (a) Rev 0.0 - 08/01/98 GE Energy Proprietary Information


g INSPECTION REPORT
Gas Turbine Maintenance Turbine
MS 3002, 5002 Buckets, 1st Stage
Date Turbine S/N Prepared by
FSR # Sketches Enclosed? Photos Enclosed?
Data Type

Bucket Conditions (Enter codes)


Bucket Foreign
Position Crack Erosion Corrosion Object
S/N Location Code Length Tip Rubs Height Width Depth Damage Disposition

Comments:

GT9000 Sheet: (b) Rev 0.0 - 08/01/98 GE Energy Proprietary Information