Professional Documents
Culture Documents
323-1851-194 (6500 R14.0 CLI T-Series) Issue1
323-1851-194 (6500 R14.0 CLI T-Series) Issue1
323-1851-194 (6500 R14.0 CLI T-Series) Issue1
LEGAL NOTICES
THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF CIENA CORPORATION AND ITS RECEIPT
OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS CONTENTS, OR TO MANUFACTURE,
USE, OR SELL ANYTHING THAT IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT
THE SPECIFIC WRITTEN AUTHORIZATION OF CIENA CORPORATION IS STRICTLY FORBIDDEN. EVERY EFFORT HAS BEEN
MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS COMPLETE AND ACCURATE AT THE TIME OF
PUBLISHING; HOWEVER, THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE. While the information
in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing CIENA PROVIDES THIS
DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or
products described in this document are subject to change without notice. For the most up-to-date technical publications, visit
www.ciena.com.
The material contained in this document is also protected by copyright laws of the United States of America and other countries. It may
not be reproduced or distributed in any form by any means, altered in any fashion, or stored in a data base or retrieval system, without
express written permission of the Ciena Corporation.
Security
Ciena cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access.
LICENSE AGREEMENT
ATTENTION
If you are using the PDF format of this document, clicking a link
brings you to the end of the section for that link. To see the start of
the linked section, scroll up the document.
Note: Some commands (such as command to generate SSL certificates) take longer than expected to run and return a timeout error, but
still run successfully.
Table of Contents
>
Table of Contents Previous Section Next Section
Adjacency
adjacencies adjacency create Create the Adjacency Application.
adjacencies fiber set Edit the Fiber Adjacency Application.
adjacencies adjacency set Edit the Adjacency Application.
adjacencies adjacency delete Delete the Adjacency Application.
adjacencies fiber show Retrieve the Adjacency Application attributes.
adjacencies connval-status show Retrieve the Connection Validation status.
adjacencies spli show Retrieve Service-Photonic Layer Interopt (SPLI) shelf database, which
contains far-end NE information.
adjacencies spli delete Delete all UNRELIABLE entries or a particular entry. For a particular entry
user must provide SHELF and INDEX, only entry with match 0 can be
deleted.
adjacencies adjacency show Retrieve the Adjacency Application attributes.
adjacencies line set Edit the OSC Adjacency Application.
adjacencies line show Retrieve the OSC Adjacency Application attributes.
adjacencies tx set Edit the Tx-Node Adjacency Application.
adjacencies tx show Retrieve the Tx-Node Adjacency Application attributes.
adjacencies rx set Edit the Rx-Node Adjacency Application.
adjacencies rx show Retrieve the Rx-Node Adjacency Application attributes.
AID Descriptions
AID Type Format Values
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[41..44]S[3..6]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[41..44]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..24]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[41..44]S[3..6]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[41..44]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..24]
T24)
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..8]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..8]
ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..3]-[1..12]
ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..3]-[1..12]
ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
Input Parameter Description
Parameter Value Description Notes
adj-type LINE Line Adjacency
TX Tx Adjacency
RX Rx Adjacency
CMD CMD Adjacency
LIM LIM Adjacency
WSS WSS Adjacency
OPM OPM Adjacency
OSC OSC Adjacency
TXRX TXRX Adjacency
FIM FIM Adjacency
AMP AMP Adjacency
OTDR OTDR Adjacency
UNKNOWN Unknown
clfi string Common Language A string of less than 64
Facility Identifier. characters.
Customer
provisionable label for
the adjacency.
layer LINE SONET Line Layer
SECT SONET Section Layer
PHYS Physical Layer
L1OTN Layer 1 OTN layer
L2PHYS Layer 2 physical layer
L2MON Layer 2 monitoring
layer
OTU OTU layer
SUBPORT Subport Layer
PTP PhysicalTermination
Point Layer
PEER Virtual Peer for Point
to Multi-Point
Configurations
ops-fe-addr string Points to the trunk Must be provisioned
OPS adjacent to the using the following
card. format OPS-shelf-slot-
port
prov-addr-form NULL
TID-PRT TID Port
TID-SL-PRT TID Slot Port
TID-SL-SBSL-PRT TID Slot SubSlot Port
TID-SH-PRT TID Shelf Port
TID-SH-SBSH-PRT TID Shelf SubShelf
Port
TID-SH-SL-PRT TID Shelf SlotPort
TID-SH-SL-SBSL-PRT TID Shelf Slot Subslot
Port
TID-SH-SBSH-SL-PRT TID Shelf SubShelf
SlotPort
TID-SH-SBSH-SL-SBSL-PRT TID Shelf SubShelf
Slot SubSlot Port
TID-BAY-SHL-SL-PRT TID Bay ShelfLabel
Slot Port
TID-SH-SL-PRT-SBPRT TID Shelf Slot Port
SubPort
TID-SH-SL-SBSL-PRT-SBPRT TID Shelf Slot SubSlot
Port SubPort
NODENAME-SL-PRT NODENAME Slot Port
SHNAME-SL-PRT ShelfName Slot Port
TID-SH-SL-PRTLBL TID Shelf Slot
Port(label)
TID-SH-SL-PRT-INSTANCE TID Shelf Slot Port
PeerInstance
NODENAME-SL-PRTLBL NODENAME Slot
Port(label)
prov-fe-addr string Provisioned far end The provisioned far
address. end address should be
surrounded by a pair
of double quotes.
AID Descriptions
AID Type Format Values
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..2]
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..2]
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[41..44]S[3..6]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[41..44]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..24]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[41..44]S[3..6]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[41..44]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..24]
T24)
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..8]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..8]
OTDR4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..4]
OTDR4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..4]
FIM ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
FIM ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
RLA ADJ (6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[21..26]S[2..11]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[21..26]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[2..3,5,11..12]
RLA ADJ (6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[21..26]S[2..11]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[21..26]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[2..3,5,11..12]
Input Parameter Description
Parameter Value Description Notes
drift-thresh DECIMAL Drift Threshold The threshold will be
of the format "xx.xx"
and dB will be
assumed.
excess-loss string Excess Loss Excess Loss Input in
dB
fiber-loss-major-thresh string Fiber Loss Major Provisioned Threshold
Threshold in dB for reporting a
major High Fiber Loss
alarm.
fiber-loss-minor-thresh string Fiber Loss Minor Provisioned Threshold
Threshold in dB for reporting a
minor High Fiber Loss
alarm.
pad-loss string Pad Loss Provisioned Pad Loss
in dB
AID Descriptions
AID Type Format Values
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..2]
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..2]
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[41..44]S[3..6]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[41..44]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..24]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[41..44]S[3..6]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[41..44]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..24]
T24)
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..8]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..8]
OTDR4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..4]
OTDR4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..4]
FIM ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
FIM ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
RLA ADJ (6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[21..26]S[2..11]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[21..26]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[2..3,5,11..12]
RLA ADJ (6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[21..26]S[2..11]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[21..26]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[2..3,5,11..12]
PTP (6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[1..40]S[1..4]
PTP (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..40]
PTP (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..40]
ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..3]-[1..12]
ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..3]-[1..12]
ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
Input Parameter Description
Parameter Value Description Notes
adj-type LINE Line Adjacency
TX Tx Adjacency
RX Rx Adjacency
CMD CMD Adjacency
LIM LIM Adjacency
WSS WSS Adjacency
OPM OPM Adjacency
OSC OSC Adjacency
TXRX TXRX Adjacency
FIM FIM Adjacency
AMP AMP Adjacency
OTDR OTDR Adjacency
UNKNOWN Unknown
clfi string Common Language A string of less than 64
Facility Identifier. characters.
Customer
provisionable label for
the adjacency
layer LINE SONET Line Layer
SECT SONET Section Layer
PHYS Physical Layer
L1OTN Layer 1 OTN layer
L2PHYS Layer 2 physical layer
L2MON Layer 2 monitoring
layer
OTU OTU layer
SUBPORT Subport Layer
PTP PhysicalTermination
Point Layer
PEER Virtual Peer for Point
to Multi-Point
Configurations
ops-fe-addr string Points to the trunk Must be provisioned
OPS adjacent to the using the following
card. format OPS-shelf-slot-
port
prov-addr-form NULL
TID-PRT TID Port
TID-SL-PRT TID Slot Port
TID-SL-SBSL-PRT TID Slot SubSlot Port
TID-SH-PRT TID Shelf Port
TID-SH-SBSH-PRT TID Shelf SubShelf
Port
TID-SH-SL-PRT TID Shelf SlotPort
TID-SH-SL-SBSL-PRT TID Shelf Slot Subslot
Port
TID-SH-SBSH-SL-PRT TID Shelf SubShelf
SlotPort
TID-SH-SBSH-SL-SBSL-PRT TID Shelf SubShelf
Slot SubSlot Port
TID-BAY-SHL-SL-PRT TID Bay ShelfLabel
Slot Port
TID-SH-SL-PRT-SBPRT TID Shelf Slot Port
SubPort
TID-SH-SL-SBSL-PRT-SBPRT TID Shelf Slot SubSlot
Port SubPort
NODENAME-SL-PRT NODENAME Slot Port
SHNAME-SL-PRT ShelfName Slot Port
TID-SH-SL-PRTLBL TID Shelf Slot
Port(label)
TID-SH-SL-PRT-INSTANCE TID Shelf Slot Port
PeerInstance
NODENAME-SL-PRTLBL NODENAME Slot
Port(label)
prov-fe-addr string Provisioned far end The provisioned far
address. end address should be
surrounded by a pair
of double quotes.
Syntax Definition
Parameter Attributes Description Notes
adj M AID
date M Connection Validation
Date Tag
time M Connection Validation
Time Tag
fiber-loss M Measured Fiber Loss
status M CV status
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
index INT Index associated with n/a
the far-end shelf entry.
AID Descriptions
AID Type Format Values
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..2]
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-[1..2]S[3..6]
portSsubport
AMP4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..2]
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[41..44]S[3..6]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[41..44]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..24]
T12)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[41..44]S[3..6]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[41..44]
T24)
CCMD16X12 ADJ (6500- ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..24]
T24)
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..8]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..4]-
portSsubport [41..42]S[3..10]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[41..42]
CCMD8X4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..8]
OTDR4 ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1..4]
OTDR4 ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1..4]
FIM ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
FIM ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[71..78]-[1..120]
RLA ADJ (6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[21..26]S[2..11]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[21..26]
RLA ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[2..3,5,11..12]
RLA ADJ (6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[21..26]S[2..11]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[21..26]
RLA ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[2..3,5,11..12]
PTP (6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[1..40]S[1..4]
PTP (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1..40]
PTP (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1..40]
ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..3]-[1..12]
ADJ (6500-T12) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..3]-[1..12]
ADJ (6500-T24) ADJ-shelf-slotSsubslot- ADJ-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
ALL ADJ (6500-T12) ADJ-shelf-slot-ALL ADJ-[0..992]-[1..12,71..78]-ALL
ALL ADJ (6500-T24) ADJ-shelf-slot-ALL ADJ-[0..992]-[1..24,71..78]-ALL
ALL ADJ (6500-T12) ADJ-shelf-slotSsubslot-ALL ADJ-[0..992]-[1..12]S[1..4]-ALL
ALL ADJ (6500-T24) ADJ-shelf-slotSsubslot-ALL ADJ-[0..992]-[1..24]S[1..4]-ALL
ALL ADJ ADJ-shelf-ALL ADJ-[0..992]-ALL
ALL objects ALL ALL
ALL objects ALL ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
fe-addr-pattern string Search pattern for far Return the adjcencies
end address. whose far-end
addresses contain the
given string.
Syntax Definition
Parameter Attributes Description Notes
aid M AID
adj-stat O Adjacency status. n/a
adj-type O Adjacency Type. n/a
clfi M Common Language A string of less than 64
Facility Identifier. characters.
Customer
provisionable label for
the adjacency.
disc-addr-form O Discovered far end n/a
address format.
disc-fe-addr O Discovered far end n/a
address.
layer O Layer n/a
ops-fe-addr O Points to the trunk Must be provisioned
OPS adjacent to the using the following
card. format OPS-shelf-slot-
port
port-label O Port Label
prov-addr-form O Provisioned far end n/a
address format.
prov-fe-addr O Provisioned far end n/a
address.
pst O Identify the primary
state
sst M L Identify the secondary
state
AID Descriptions
AID Type Format Values
Line ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[5]
Line ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[5]
Input Parameter Description
Parameter Value Description Notes
bundle-id string Bundle ID. Tracks Shared Risk
Link Groups
fiber-type UNKNOWN Unknown fiber type
NDSF Non-Dispersion Shifted
Fiber
TWC TrueWave Classic
LS Lambda Shifted Single
Mode Fiber
DSF Dispersion Shifted
Single Mode Fiber
TWRS TrueWave Reduced
Slope
TWP TrueWave Plus
LEAF Large Effective Area
Fiber
ELEAF Enhanced Effective
Area Fiber
FL Freelight
AW Allwave
TWREACH Truewave Reach
TERALIGHT Teralight
PSC Pure Silica Core
OTHER other
NDSFLWP Non-Dispersion Shifted
Fiber Low Water Peak
TEWAVULL TeraWave ULL
EX2000 EX2000
min-span-loss DECIMAL Minimum Span Loss in The minimum span
dB. loss will be of the
format "xx.x" and dB
will be assumed.
span-loss-margin DECIMAL Span Loss Margin in The span loss margin
dB. will be of the format
"xx.x" and dB will be
assumed.
targ-span-loss DECIMAL Target Span Loss in The target span loss
dB. will be of the format
"xx.x" and dB will be
assumed.
AID Descriptions
AID Type Format Values
Tx ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[1,3,5...23]
Tx ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[1,3,5...23]
Tx ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[1,3,5,7]
Tx ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[1,3,5,7]
RLA ADJ TX(6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[21..26]S[7..11]
RLA ADJ TX(6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[21..26]S[7..11]
Tx ADJ (6500-R4) ADJ-shelf-slot-port ADJ-[0..992]-[1..8]-[1,3,5...31]
Input Parameter Description
Parameter Value Description Notes
active TRUE
FALSE
auto-disc AUTO Auto Provisioning of
Type Enabled
MANUAL Auto Provisioning of
Type Disabled
bias DECIMAL OSNR bias in dB. The bias will be of the
(-10.00-10.00) format "xx.xx" and dB
will be assumed.
center-frequency DECIMAL Captures Tx frequency The frequency will be
(186.325000-190.975000, in THz. of the format
191.325000-196.125000) "xxx.xxxxxx" and THz
will be assumed.
cktid string Circuit Identifier. A string of less than 64
Customer characters.
provisionable label for
the adjacency TX.
ctrl-freq-offset DECIMAL Control frequency The frequency will be
(-4800-4800) offset in GHz. of the format
"xxxx.xxx" and GHz
will be assumed.
cur-pow DECIMAL Current launch power The power will be of
(-30.00-20.00) in dBm. the format "xx.xx" and
dBm will be assumed.
Need to add an
indicator if not
available
express-delete TRUE
FALSE
exp-res-time DECIMAL Expected Restoration
(0-255) Time.
fec DECIMAL FEC Gain in dB. The gain will be of the
(0.00-20.00) format "xx.xx" and dB
will be assumed.
freqresolution DECIMAL Indicates the recurring
(0.001-1.000) frequency step that is
allowed to be
configured on the
transponder.
laser-centering OFF
ON
STANDBY
UNKNOWN
laser-centering-range DECIMAL Laser Centering
(0.000-2.500) Range.
link-opt-mode LNKSTDMODE Standard
LNKSNRMODE SNR-Tolerance
LNKTRACKINGMODE Fast-Tracking
LNKSPECTRALMODE Spectral-Efficiency
LNKLATENCYMODE Latency
LNKNRBWCHMODE Narrow
LNKNONLCHMODE Non-linear
LNKFLINEMODE Foreign
LNKRSVMODE1 Reserved-1
LNKRSVMODE2 Reserved-2
LNKRSVMODE3 Reserved-3
CUSTOM Custom
UNKNOWN Unknown
loopback-status UNKNOWN Loopback test not run
or currently running.
PASS Latest loopback test
passed.
FAIL Latest loopback test
failed.
FAIL-CHOUTFL EXCEEDS 1 dB Latest loopback test
failed - CH OUT port
Fiber Loss exceeds 1
dB.
FAIL-TTI Mismatch Latest loopback test
failed - TTI Mismatch.
FAIL-TTI Fail Latest loopback test
failed - TTI Fail.
FAIL-TXTUNING Latest loopback test
failed - TX TUNING IN
PROGRESS.
FAIL-CHINLOS Latest loopback test
failed - CH IN LOS.
FAIL-CHINFL EXCEEDS 1 dB Latest loopback test
failed - CH IN port
Fiber Loss exceeds 1
dB.
FAIL-CHOUTLOS Latest loopback test
failed - CH OUT LOS.
FAIL-NOTREADY Latest loopback test
failed - EQUIPMENT
NOT READY.
FAIL-RXLOS Latest loopback test
failed - RX LOS.
FAIL-RXLOF Latest loopback test
failed - RX LOF.
FAIL-RXLOCH Latest loopback test
failed - RX LOCH.
FAIL-RXLOC Latest loopback test
failed - RX LOC.
FAIL-RXLOM Latest loopback test
failed - RX LOM.
FAIL-RXSD Latest loopback test
failed - RX SD.
FAIL-PREFEC SF Latest loopback test
failed - RX PREFEC
SF.
FAIL-CMDCMNOUTHFL Latest loopback test
failed - CMD Common
Out HFL
FAIL-CMDCMNOUTLOS Latest loopback test
failed - CMD Common
Out Far End in LOS.
FAIL-CMDCMNINHFL Latest loopback test
failed - CMD Common
In Far End HFL
FAIL-CMDCMNINLOS Latest loopback test
failed - CMD Common
In LOS.
FAIL-CMDOPMHFL Latest loopback test
failed - CMD OPM
HFL.
FAIL-TXSPLIMGMTOFF Latest loopback test
failed - SPLI
Management is
disabled on the
transponder.
MANUAL-VALIDATION Latest loopback test
REQUIRED Manual: Validation
Required.
max-freq-guard-band DECIMAL Indicates the minimum
(0.000-4800.000) required frequency
spacing for the next
NMC.
max-pow DECIMAL Max launch power in The power will be of
(-30.00-20.00) dBm. the format "xx.xx" and
dBm will be assumed.
min-freq-guard-band DECIMAL Indicates the minimum
(0.000-4800.000) required frequency
spacing for the
previous NMC.
min-pow DECIMAL Min launch power in The power will be of
(-30.00-20.00) dBm. the format "xx.xx" and
dBm will be assumed.
min-spectral-width DECIMAL Tx Network Media The bandwidth will be
(12.500-4800.000) Channel Signal of the format
Bandwidth in GHz "xxxx.xxx" and GHz
including majority of will be assumed.
signal power, laser
aging/drift, and laser
control loop tolerance.
mod-class UNKNOWN Unknown
UNDEFINED Undefined
2G5 2.5G
10G 10G
10GNGM 10G NGM
40G 40G
CUSTOM1 Custom1
CUSTOM2 Custom2
CUSTOM3 Custom3
CUSTOM4 Custom4
CUSTOM5 Custom5
CUSTOM6 Custom6
100G 100G
40GULH 40GULH
100GWL3 100GWL3
100GWL3BPSK 100GWL3BPSK
100GWL38QAM 100GWL38QAM
100GWL316QAM 100GWL316QAM
100GWL34ASK 100GWL34ASK
35GBAUD_100G 35GBAUD_100G
35GBAUD_150G 35GBAUD_150G
35GBAUD_200G 35GBAUD_200G
35GBAUD_250G 35GBAUD_250G
56GBAUD_100G 56GBAUD_100G
56GBAUD_150G 56GBAUD_150G
56GBAUD_200G 56GBAUD_200G
56GBAUD_250G 56GBAUD_250G
56GBAUD_300G 56GBAUD_300G
56GBAUD_350G 56GBAUD_350G
56GBAUD_400G 56GBAUD_400G
SLIC SLIC
WL5e_general WL5e_general
CFP2DCO_28GBAUD_100G CFP2DCO_28GBAUD_100G
CFP2DCO_32GBAUD_100G CFP2DCO_32GBAUD_100G
CFP2DCO_32GBAUD_200G CFP2DCO_32GBAUD_200G
och-tx-blanking OFF, ON Request(ON) or
Release(OFF)
blanking on the
corresponding OCLD.
paired-rx YES Paired Rx
NO Not paired
path-disp DECIMAL Path Dispersion at a
(-999999999-999999999) given frequency.
prov-fe-pec string Provisioned FE PEC
rate UNKNOWN Unknown
2.5G 2.5G
10.0G 10.0G
10.7G 10.7G
11.1G 11.1G
11.3G 11.3G
4.0G 4.0G
40.0G 40.0G
100.0G 100.0G
50.0G 50.0G
200.0G 200.0G
150.0G 150.0G
250.0G 250.0G
300.0G 300.0G
350.0G 350.0G
400.0G 400.0G
450.0G 450.0G
500.0G 500.0G
550.0G 550.0G
600.0G 600.0G
650.0G 650.0G
700.0G 700.0G
750.0G 750.0G
800.0G 800.0G
sig-bw-10dB DECIMAL Tx Signal Bandwidth in The bandwidth will be
(12.500-4800.000) GHz measured at 10 of the format
dBm less than peak "xxxx.xxx" and GHz
power. will be assumed.
sig-bw-3dB DECIMAL Tx Signal Bandwidth in The bandwidth will be
(12.500-4800.000) GHz measured at 3 of the format
dBm less than peak "xxxx.xxx" and GHz
power. will be assumed.
syncprov TRUE
FALSE
trans-mode string Transponder
Transmission Mode
tuning-mode PERFORMANCE_OPTIMIZED Performance
Optimized Tuning
Mode
ACCELERATED Accelerated Tuning
Mode
FAST Fast Tuning Mode
UNKNOWN Unknown
tx-ctrl NO
YES
UNKNOWN
tx-disp-mode AUTOMATIC Automatic
FIXEDTX Fixed
UNKNOWN Unknown
tx-pre-comp DECIMAL Tx Dispersion
(-999999999-999999999) Compensation Value.
type string Tx type. n/a
AID Descriptions
AID Type Format Values
Rx ADJ (6500-T12) ADJ-shelf-slot-port ADJ-[0..992]-[1..12]-[2,4,6...24]
Rx ADJ (6500-T24) ADJ-shelf-slot-port ADJ-[0..992]-[1..24]-[2,4,6...24]
Rx ADJ (6500-T12) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..12]S[1..4]-[2,4,6,8]
Rx ADJ (6500-T24) ADJ-shelf-slotSsubslot-port ADJ-[0..992]-[1..24]S[1..4]-[2,4,6,8]
RLA ADJ RX(6500-T12) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..12]-[21..26]S[2..6]
RLA ADJ RX(6500-T24) ADJ-shelf-slot-portSsubport ADJ-[0..992]-[1..24]-[21..26]S[2..6]
Rx ADJ (6500-R4) ADJ-shelf-slot-port ADJ-[0..992]-[1..8]-
Input Parameter Description
Parameter Value Description Notes
auto-disc AUTO Auto Provisioning of
Type Enabled
MANUAL Auto Provisioning of
Type Disabled
center-frequency DECIMAL Captures Rx frequency The frequency will be
(186.325000-190.975000, in THz. of the format
191.325000-196.125000) "xxx.xxxxxx" and THz
will be assumed.
cur-rx-corr-factor DECIMAL Captures the per The channel correction
(-10.00-10.00) channel correction factor will be of the
factor received from format "xx.xx" and dB
the Rx in dB. will be assumed.
dtrans-neg DECIMAL Maximum negative The transient will be of
(-10.00-10.00) transient in dB/s. the format "xx.xx" and
dB/s will be assumed.
dtrans-pos DECIMAL Maximum positive The transient will be of
(-10.00-10.00) transient in dB/s. the format "xx.xx" and
dB/s will be assumed.
ignore-rx-faults FALSE, TRUE This flag blocks n/a
reporting receiver
faults to OSRP.
nom-input DECIMAL Typical per channel The power will be of
(-40.00-20.00) operational power the format "xx.xx" and
recommended for the dBm will be assumed.
receiver in dBm.
overload-thresh DECIMAL Maximum per chanel The power will be of
(-40.00-20.00) power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
paired-tx YES Paired Tx
NO Not paired
prov-fe-pec string Provisioned FE PEC
sensitivity-thresh DECIMAL Minimum per channel The power will be of
(-40.00-20.00) power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
sync-prov TRUE
FALSE
type string Rx type. n/a
Alarm Provisioning
almprofile show Retrieve Alarm Profile: this command allows the user to retrieve the list of
alarms and their associated profile status.
almprofile default show Retrieve Default Alarm Profile: this command will allow the user to retrieve the
current default profile of an AIDTYPE.
almprofile active show Retrieve Active Alarm Profile: this command allows the user to view the current
alarm profile that is associated with a given equipment or facility object type.
almprofile active set Set Active Alarm Profile: this command causes an alarm profile to become
active on a specified facility or equipment entity.
almprofile default set Set Default Alarm Profile: this command allows the user to change the default
profile of an AIDTYPE (equipment or facility type). The profile will subsequently
be used for all newly-created entities of that type.
almprofile attribute set-profile Set Alarm Profile Attribute : this command is used to change the alarm
provisioning status within a given profile and re-evaluates the standing alarms
who are using this profile.
almprofile name set Set Alarm Profile Name: this command allows the user to change the profile
name.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
prflid PROFILE0 FACTORY DFLT Only VT1, VT2 and
COM facility types
have this profile. Each
alarm status of this
profile is "NOT
MONITORED" for VT1
and VT2 facility types.
Each alarm status is
"ENABLED", except
LAN-15 failed and Disk
75% full alarm status
is "DISABLED", in this
profile for COM facility
type.
PROFILE1 ALL ENABLED Except VT1, VT2 and
COM facility types, this
profile is initial default
profile for every facility
type
PROFILE2 ALL DISABLED
PROFILE3 USER EDITABLE
PROFILE4 USER EDITABLE
PROFILE5 USER EDITABLE
info Y
N
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
aidtype M Type of AID
prflid M Profile id
prflname M Profile name alarm profile name can
be up to 20 characters
long and must be
enclosed within
quotation marks
(quotation marks and
backslash to be
excluded from name)
conddescr O Condition description
giving a textual outline
of the event.
alm-id O Alarm identifier non-zero unsigned
integer
hi-sev O Alarm High Severity
lo-sev O Alarm Low Severity
state O Indicates whether the
alarm is enabled or
disabled in this profile.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL
ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
info Y
N
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
aidtype M Type of AID
prflid M Profile id
prflname M Profile name alarm profile name can
be up to 20 characters
long and must be
enclosed within
quotation marks
(quotation marks and
backslash to be
excluded from name)
conddescr O Condition description
giving a textual outline
of the event.
alm-id O Alarm identifier non-zero unsigned
integer
hi-sev O high severity.
lo-sev O low severity.
state O Indicates whether the
alarm is enabled or
disabled in this profile.
Output Parameter Description
Parameter Value Description Notes
shelf ident aid
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
prflid PROFILE0 FACTORY DFLT Only VT1, VT2 and
COM facility types
have this profile. Each
alarm status of this
profile is "NOT
MONITORED" for VT1
and VT2 facility types.
Each alarm status is
"ENABLED", except
LAN-15 failed and Disk
75% full alarm status
is "DISABLED", in this
profile for COM facility
type.
PROFILE1 ALL ENABLED Except VT1, VT2 and
COM facility types, this
profile is initial default
profile for every facility
type
PROFILE2 ALL DISABLED
PROFILE3 USER EDITABLE
PROFILE4 USER EDITABLE
PROFILE5 USER EDITABLE
prflname string Profile name alarm profile name can
be up to 20 characters
long and must be
enclosed within
quotation marks
(quotation marks and
backslash to be
excluded from name)
conddescr string Condition description
giving a textual outline
of the event.
alm-id INT Alarm identifier non-zero unsigned
integer
hi-sev CR Critical
MJ Major
MN Minor
NA Not Alarmed
NAP Not Applicable
lo-sev CR Critical
MJ Major
MN Minor
NA Not Alarmed
NAP Not Applicable
state ENABLED
DISABLED
NOTMONITORED
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
target-aid ident A valid AID for the
selected AIDTYPE. It
is required for all
AIDTYPE except COM
and SECU.
Syntax Definition
Parameter Attributes Description Notes
aidtype M aidtype
shelf M aid
prflid M Profile id
prflname M Profile Name
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
prflid PROFILE0 FACTORY DFLT Only VT1, VT2 and
COM facility types
have this profile. Each
alarm status of this
profile is "NOT
MONITORED" for VT1
and VT2 facility types.
Each alarm status is
"ENABLED", except
LAN-15 failed and Disk
75% full alarm status
is "DISABLED", in this
profile for COM facility
type.
PROFILE1 ALL ENABLED Except VT1, VT2 and
COM facility types, this
profile is initial default
profile for every facility
type
PROFILE2 ALL DISABLED
PROFILE3 USER EDITABLE
PROFILE4 USER EDITABLE
PROFILE5 USER EDITABLE
target-aid ident AID of the facility or
equipment to make the
specified alarm profile
active on it. It is
required for all
AIDTYPE except COM
and SECU.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
prflid PROFILE0 FACTORY DFLT Only VT1, VT2 and
COM facility types
have this profile. Each
alarm status of this
profile is "NOT
MONITORED" for VT1
and VT2 facility types.
Each alarm status is
"ENABLED", except
LAN-15 failed and Disk
75% full alarm status
is "DISABLED", in this
profile for COM facility
type.
PROFILE1 ALL ENABLED Except VT1, VT2 and
COM facility types, this
profile is initial default
profile for every facility
type
PROFILE2 ALL DISABLED
PROFILE3 USER EDITABLE
PROFILE4 USER EDITABLE
PROFILE5 USER EDITABLE
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
prflid PROFILE3 USER EDITABLE
PROFILE4 USER EDITABLE
PROFILE5 USER EDITABLE
almid INT Alarm identifier non-zero unsigned
integer
alrmstat ENABLED
DISABLED
hisev CR Critical
MJ Major
MN Minor
NA Not Alarmed
losev CR Critical
MJ Major
MN Minor
NA Not Alarmed
Alarms
alarms alarm show Retrieve Alarm All : this command retrieves all the current alarms from the specified
network element.
events ao show Retrieve Automatic Output : This command retrieves an historical list of automatic
output (AO) messages stored on the NE. The message list provides historical
autonomous messages including all events, alarm raises and clears, and
environmental alarms. The AO list cannot be deleted, reset, or altered. The
message list holds messages in a first-in-first-out buffer:
alarms condition show Retrieve Conditions All : this command retrieves the current conditions (alarm or
status) from the specified network element.
events last-seq-num show Retrieve Last Sequence Number :Retrieve the Last Sequence Number Used
alarms cutoff operate Operate Alarm Cut-Off Command: Instructs a network element to cut off the office
audible alarm indications without changing the other alarm indications. The result of
this command is identical to manually pressing the ACO button on the network
element circuit pack.
alarms security clear Manual Alarm Clear: this command is used to clear all present security alarms on
the NE.
AID Descriptions
Key Type Format
dgn-type An identifier which is used to provide the following definitions
for Preside: 10 digit unique id for Alarm raised instance, 4 digit
M3100 Probable Cause, 4 digit documentation index
Input Parameter Description
Parameter Value Description Notes
severity CR Critical
MJ Major
MN Minor
ALL ALL
state ENABLED, DISABLED, BOTH Alarm status: Controls Disabled alarms
whether to retrieve cannot be filtered by
only enabled alarms, severity, i.e. if
only disabled alarms, ALRMSTAT value is
or both enabled and DISABLED/BOTH then
disabled alarms. there is no need to set
a value for the
ALRMSEVER
parameter.
Syntax Definition
Parameter Attributes Description Notes
aid O aid
aidtype O aidtype
condtype M The condition type for
an alarm or a reported
event. GR-833-CORE
Appendix C stipulates
20 characters max.
dirn O The direction of the
alarm condition and is
relative to the entity
identified by the AID.
locn O The location
associated with a
particular command.
ntfcncde M The notification code
for the message.
ocrdat M The date when the
alarm occurred
ocrtm M The time when the
alarm occurred
srveff M The effect on service
caused by the standing
or alarm condition.
aiddet M Mode of port, if
applicable
conddescr M Condition description
giving a textual outline
of the event.
dgn-type M An identifier which is Each number will be
used to provide the zero padded to the
following definitions for correct size.
Preside: 10 digit
unique id for Alarm
raised instance, 4 digit
M3100 Probable
Cause, 4 digit
documentation index
additional-info O Additional info
bay-num O Bay Number Range 0..255 This
parameter defines the
bay ID where the shelf
is located. It is
optionally reported in
AO messages.
card-type O Card Type
clfi O Common Language A string of upto 64
Facility characters.
Identifier.Customer
provisionable label for
a facility.
fic O FIC Frame Identification
Code. This is
optionally reported in
AO messages.
label O Label
mode M Mode of port, if
applicable
name O Name
phys-shelf O Physical Shelf Number Range 0..9 This
parameter defines the
physical shelf number
within a bay. It is
optionally reported in
AO messages.
sig-layer O Signal Layer
subnet-name O Subnet Name Subnet name, range
up to 36 alphanumeric
characters.
wavelength O Wavelength Wavelength (nm). This
is the wavelength
associated with the
AID.
year M A four character string
used to represent the
alarm occurrence year.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
atag-seq INT Autonomous Event Multiple or range of
(1-2000000000) Sequence Number. values can be
Range format: specified by using the
low_ATAG&&high_AT & or && notation. May
AG Group format: be used together with
ATAG_1&ATAG_2&AT MSGTYPE.
AG_3...
count INT Count of AO to be
(1-65535) retrieved.
event-msg-type ALM Alarms, SCs and TCs Applicable for UPC
Levels 1 and above
EVT TCA Events Only Applicable for UPC
(Threshold Crossing Levels 1 and above
Alerts)
ALM-ENV Environmental Alarms Applicable for UPC
Levels 1 and above
INHIBITED Inhibited Alarms Applicable for UPC
Levels 1 and above
DBCHG Database Change Applicable for UPC
events Levels 4 and above
STATUS Status events Applicable for UPC
Levels 4 and above
ECHO Command Echos Applicable for UPC
Levels 4 and above
ALL All AO except Inhibited Applicable for UPC
alarms Levels 4 and above
order ASCENDING Ascending (oldest to
newest)
DESCENDING Descending (newest to
oldest)
Syntax Definition
Parameter Attributes Description Notes
atag-seq M Autonomous Event
Sequence Number
msg-type M Autonomous Event
Message Type
subtype O Autonomous Event
Message Subtype
ao_message M Autonomous Message
AID Descriptions
Key Type Format
dgn-type An identifier which is used to provide the following definitions
for Preside: 10 digit unique id for Alarm raised instance, 4 digit
M3100 Probable Cause, 4 digit documentation index
Input Parameter Description
Parameter Value Description Notes
severity CR Critical
MJ Major
MN Minor
ALL ALL
state ENABLED, DISABLED, BOTH Alarm status: Controls Disabled alarms
whether to retrieve cannot be filtered by
only enabled alarms, severity, i.e. if
only disabled alarms, ALRMSTAT value is
or both enabled and DISABLED/BOTH then
disabled alarms. there is no need to set
a value for the
ALRMSEVER
parameter.
Syntax Definition
Parameter Attributes Description Notes
aid O aid
aidtype O aidtype
conddescr M Condition description
giving a textual outline
of the event.
condtype M Condition type for an
alarm or a reported
event. GR-833-CORE
Appendix C stipulates
20 characters max.
dirn O The direction of the
alarm condition and is
relative to the entity
identified by the AID.
locn O The location
associated with a
particular command.
ntfcncde M Notification code for
the message.
ocrdat M The date when the
alarm occurred
ocrtm M The time when the
alarm occurred
srveff O The effect on service
caused by the standing
or alarm condition.
tmper O Time Period
additional-info O Additional info
bay-num O Bay Number Range 0..255 This
parameter defines the
bay ID where the shelf
is located. It is
optionally reported in
AO messages.
card-type O Card Type
clfi O Common Language A string of upto 64
Facility characters.
Identifier.Customer
provisionable label for
a facility.
dgn-type M An identifier which is Each number will be
used to provide the zero padded to the
following definitions for correct size.
Preside: 10 digit
unique id for Alarm
raised instance, 4 digit
M3100 Probable
Cause, 4 digit
documentation index
fic O FIC Frame Identification
Code. This is
optionally reported in
AO messages.
label O Label
mode M Mode of port, if
applicable
name O Name
phys-shelf O Physical Shelf Number Range 0..9 This
parameter defines the
physical shelf number
within a bay. It is
optionally reported in
AO messages.
sig-layer O Signal Layer
subnet-name O Subnet Name Subnet name, range
up to 36 alphanumeric
characters.
wavelength O Wavelength Wavelength (nm). This
is the wavelength
associated with the
AID.
year M A four character string
used to represent the
alarm occurrence year.
Output Parameter Description
Parameter Value Description Notes
aid ident aid
aidtype OPTMON Optical Monitoring
VOA VOA facility
AMP AMP facility
DOC DOC facility
RAMAN RAMAN facility
ADJ Adjacency
OSC OSC facility
SECU Security related
EQPT Equipment
COM Common to Shelf or
SP
OC3 OC3 facility
OC12 OC12 facility
OC48 OC48 facility
OC192 OC192 facility
OC768 OC768 facility
STS192C STS192C facility
WAN WAN client facility
OTM OTM facility
OTM2 OTM2 facility
OTM3 OTM3 facility
ETH10G ETH10G facility AID
ETHN GENERIC ETH facility
AID
PTP PTP facility AID
OTUTTP OTUTTP facility AID
ETTP ETTP facility AID
STTP STTP facility AID
ODUTTP ODUTTP facility AID
ODUCTP ODUCTP facility AID
TCM TCM facility AID
SNC Sub network
connection AID
OSRPNODE OSRPNODE AID
OSRPLINK OSRPLINK AID
OSRPLINE OSRPLINE AID
IDLER Idler facility AID
TELEMETRY Telemetry facility AID
CRSNC CRSNC facility AID
SLOTSEQ SLOTSEQ facility AID
TIDSLOTSEQ TIDSLOTSEQ facility
AID
AMPMON AMPMON facility
OTS OTS facility
FLEX FLEX facility
OTC OTC facility
PROTGRP PROTGRP facility
ODU ODU facility
CHC CHC facility
NMCC NMCC facility
OTDRCFG OTDRCFG facility
SNCG SNCG facility
ALL ALL facilities
conddescr string Condition description
giving a textual outline
of the event.
condtype string Condition type for an
alarm or a reported
event. GR-833-CORE
Appendix C stipulates
20 characters max.
dirn RCV Receive direction only
TRMT Transmit direction only
NA Not Applicable
locn NEND Near End
FEND Far End
ntfcncde CR Critical
MJ Major
MN Minor
NA Not Alarmed
ocrdat date The date when the
alarm occurred
ocrtm time The time when the
alarm occurred
srveff SA Service Affecting
NSA Not Service Affecting
tmper string Time Period
additional-info string Additional info
bay-num INT Bay Number Range 0..255 This
(0-255 Default=0) parameter defines the
bay ID where the shelf
is located. It is
optionally reported in
AO messages.
card-type string Card Type
clfi string Common Language A string of upto 64
Facility characters.
Identifier.Customer
provisionable label for
a facility.
dgn-type string An identifier which is Each number will be
used to provide the zero padded to the
following definitions for correct size.
Preside: 10 digit
unique id for Alarm
raised instance, 4 digit
M3100 Probable
Cause, 4 digit
documentation index
fic string FIC Frame Identification
Code. This is
optionally reported in
AO messages.
label string Label
mode SONET
SDH
NONE
SDHJ
name string Name
phys-shelf INT Physical Shelf Number Range 0..9 This
(0-9) parameter defines the
physical shelf number
within a bay. It is
optionally reported in
AO messages.
sig-layer string Signal Layer
subnet-name string Subnet Name Subnet name, range
up to 36 alphanumeric
characters.
wavelength string Wavelength Wavelength (nm). This
is the wavelength
associated with the
AID.
year INT A four character string
(0-9999) used to represent the
alarm occurrence year.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
seqtype DBCHGSEQ Database Change
Sequence Number
ATAGSEQ Autonomous Event
Sequence Number
BOTH Both Sequence
Numbers
ITAGSEQ Inhibited Events
Sequence Number
ALL All Sequence Number
Syntax Definition
Parameter Attributes Description Notes
atagseq O Autonomous Event
Sequence Number
dbchgseq O Database Change
Sequence Number
itagseq O Inhibited Message tag
Sequence
Application
application application create Enter application
application application delete Delete application
application application show Retrieve application data on the node
Syntax Definition
Parameter Attributes Description Notes
response O Information on
Database Content
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
autosave Y Autosave state
required
N Autosave state not
required
Syntax Definition
Parameter Attributes Description Notes
aid M AID
source M Source
backuprequired M Backup required Boolean flag indicating
if backup is required
because provisioning
database has changed
since last backup
lastbackup M Last Backup Date/time of last
configuration backup.
Format YY-MM-DD-
HH-MM-SS
state M Backup and Restore
state
Comms
comms arp proxy create Provision Proxy ARP
comms arp proxy delete Delete Proxy ARP
comms arp proxy show Retrieve Proxy ARP
comms arp table show Retrieve ARP Table.
servers dhcp set Configure the DHCP server.
servers dhcp show Retrieve settings for the DHCP server.
servers ftp set Configure the FTP server.
servers ftp show Retrieve settings for the FTP server.
comms gne create Defines this NE to be a GNE. The parameters "configuration" & "access" are
used to define the GNE configuration being deployed.
comms gne set Allows the selected parameters to be changed without completely deleting
and re-entering the GNE.
comms gne delete Deletes the GNE record. The NE is no longer tagged as being a GNE. If GNE
Type was Redundant ARP then the GNE ceases to participate in
Master/Backup service negotiations.
comms gne show Retrieve an NE's GNE designation.
servers http set Configure the regular and secure HTTP servers, REST and GRPC services
servers http show Retrieve settings for the HTTP servers, REST and GRPC services
servers netconf set Configure the NETCONF server
servers netconf show Retrieve settings for NETCONF server
comms iisis circuit create Create an integrated IS-IS circuit.
comms iisis circuit delete Delete an integrated IS-IS circuit.
comms iisis circuit show View an integrated IS-IS circuit.
comms iisis rdentry create This command accepts a route; puts it in the ISIS re-distribution list. ISIS will
re-distribute it to the ISIS network.
comms iisis rdentry delete This command accepts an ISIS re-distributed route and remove it from the
ISIS redistribution list.
comms iisis rdentry show This command retrieves all the entries of ISIS re-distribution list.
comms iisis router create Enable the integrated IS-IS router.
comms iisis router delete Disable the integrated IS-IS router.
comms iisis router show View the integrated IS-IS router configuration.
comms ip create Used to enable an IP port
comms ip delete Used to delete the IP address and associated parameters assigned to the NE
management interfaces.
comms ip set Edit IP: Used to edit the IP address and associated parameters assigned to
the NE management interfaces.
comms ip show Retrieve IP. Retrieves the IP address and associated parameters assigned to
the NE management interfaces.
comms ip-filter create Add an IP filter rule on the shelf for COLAN, ILAN and CRAFT.
comms ip-filter delete Delete a filter rule that was added using ENT-IPFILTER.
comms ip-filter show Retrieve the IP filter entries.
comms ip-nat create Enter IPNAT
comms ip-nat delete Delete IPNAT
comms ip-nat show Retrieve IPNAT
comms ip-routing-table show Retrieve IP Routing Table: Command returns a report listing all the network
entities on the network.
comms ip-static-route create Enter IP static route
comms ip-static-route delete Delete IP static route
comms ip-static-route show Retrieve IP static route
comms lan create Enter LAN: enable a LAN port.
comms lan delete Delete LAN: disable a LAN port.
comms lan set Edit LAN: modify a LAN port.
comms lan show Retrieve LAN: view a LAN port's settings.
comms llsdcc create Enter Lower Layer DCC. Adds a section data communications channel
(SDCC), line data communications channel (LDCC), or G.709 GCC to the
specified AID.
comms llsdcc delete Delete Lower Layer DCC. Deletes a section data communications channel
(SDCC), line data communications channel, or G.709 GCC based on the
specified AID.
comms llsdcc set Edit Lower Layer DCC. Modifies editable layer 2 parameters of a section data
communications channel (SDCC) or a line data communications channel
(LDCC), based on the specified AID.
comms llsdcc show Retrieve Lower Layer DCC. Retrieves information associated with a given
section data communications channel (SDCC), line data communications
channel (LDCC), or G.709 GCC based on the specified AID. The information
includes the state of the layer 2 (LAPD or PPP) link and the current settings of
editable layer 2 parameters.
comms nat set Configure the NAT service.
comms nat show Retrieve the NAT service configuration information.
comms ne-list create Add an NE into a table.
comms ne-list delete Remove an NE from a table.
comms ne-list show Retrieve a list of NEs provisioned into a table.
comms nodes show Displays a complete list of OSPF addressable nodes.
comms ospf circuit create Create an OSPF circuit.
comms ospf circuit set Edit an OSPF circuit.
comms ospf circuit delete Delete an OSPF circuit.
comms ospf circuit show View an OSPF circuit.
comms ospf adjacency show View the OSPF adjacency
comms ospf rdentry create This command accepts a route; puts it in the OSPF re-distribution list. OSPF
re-distributes it to the OSPF network.
comms ospf rdentry delete This command accepts an OSPF re-distributed route and remove it from the
OSPF redistribution list.
comms ospf rdentry show This command retrieves all the entries of OSPF re-distribution list.
comms ospf router create Enable the OSPF router.
comms ospf router set Edit the OSPF router.
comms ospf router delete Disable the OSPF router.
comms ospf router show View the OSPF router configuration.
comms ppp set Edit PPP
comms ppp show Retrieve PPP
comms ip-rpnat create Enter a single Reverse Port NAT mapping entry.
comms ip-rpnat delete Delete a single Reverse Port NAT mapping entry.
comms ip-rpnat show Retrieve the entire configured Reverse Port NAT mapping table.
comms osi-routing info show Retrieve Routing Info. Displays a complete list of ISIS addressable nodes.
The report lists the ID (empty for Express), Target ID , System ID, Type, and
Site Mgr Support (Y/N).
comms osi-routing table show Retrieve Routing Table. Displays a complete list of ISIS addressable nodes.
The report lists the OSI address of the Destination, of the Adjacency (ies),
and the OSI Cost.
ssl server certificate generate Regenerates the SSL certificate for secure HTTP access
ssl server certificate show Retrieve the SSL public key information
servers telnet set Configure the TELNET server.
servers telnet show Retrieve settings for the TELNET server.
comms tidmap show Retrieve the TIDMAP Data Cache and display the list of RNEs that have been
self discovered via the 6500's supported address resolution protocols (NNS,
AR and TARP).
comms tl1gw connections show Retrieve the status of the NEs added to the TL1 Gateway.
comms ulsdcc set Edit Upper Layer DCC. Modifies the network layer address of the OSI stack.
Three manual area addresses can be provisioned.
comms ulsdcc show Retrieve Upper Layer DCC. Retrieves manual area addresses.
comms wsc create Enter WSC: enable a WSC port.
comms wsc delete Delete WSC: disable a WSC port.
comms wsc set Edit WSC: modify a WSC port.
comms wsc show Retrieve WSC: view a WSC port's settings.
comms tl1gw config set Configure the TL1 gateway application.
comms tl1gw config show Retrieve settings for TL1 gateway application.
comms ip-acl-list create Used to add an IP ACL entry
comms ip-acl-list delete Used to delete an IP ACL entry
comms ip-acl-list reset Used to delete all IP ACL entries
comms ip-acl-list show Retrieve IP ACL entries from specified list (edit list or commit list)
comms ip-acl-stats show Retrieve IP ACL statistics
comms ip-acl-list commit Used to install ACL rules
comms ip-acl set Used to activate or deactivate the ACL
comms pktn acl-list create Used to add an PKTN ACL entry
comms pktn acl-list delete Used to delete an PKTN ACL entry
comms pktn acl-list reset Used to delete all PKTN ACL entries
comms pktn acl-list show Retrieve PKTN ACL entries from specified list (edit list or commit list)
comms pktn acl show Retrieve PKTN ACL status
comms pktn acl-list commit Used to install PKTN ACL rules
comms ndp config set Used to turn the NDP feature on or off at a shelf level
comms ndp config show Retrieve the NDP admin state
comms ndp link create Used to add an NDP link to an interface
comms ndp link delete Used to delete an NDP link from an interface
comms ndp link show Retrieve the NDP links provisioned
comms ip-address create Assign an IP address(IPv6) and associated parameters to an NE
management interface
comms ip-address set Edit the IP address(IPv6) and associated parameters assigned to the NE
management interfaces.
comms ip-address delete Delete the IP address(IPv6) and associated parameters assigned to the NE
management interfaces.
comms ip-address show Retrieve IP address(IPv6) and associated parameters assigned to the NE
management interfaces.
comms static-route create Enter IP static route
comms static-route set Edit IP static route
comms static-route delete Delete IP static route
comms static-route show Retrieve IP static route
comms sldd config set Used to enable / disable the Site Level Data Distribution feature which will
limit the scope of the AR / TR records.
comms sldd config show Retrieve the state and scope of the Site Level Data Distribution feature.
comms sldd list create Used to add an interface to the Site Level Data Distribution interface list.
comms sldd list delete Used to delete an an interface from the Site Level Data Distribution interface
list.
comms sldd list show Used to retrieve the interface list to be used by the Site Level Data
Distribution feature.
comms ip6 ndp-proxy create Enter an IP6ND-PROXY address
comms ip6 ndp-proxy set Edit an IP6ND-PROXY entry
comms ip6 ndp-proxy delete Delete an IP6ND-PROXY entry
comms ip6 ndp-proxy show Retrieve IP6 ND-PROXY
comms config set Edit Comms Settings.
comms config show Retrieve Comms Settings.
comms ospfv3 router create Enable the OSPFv3 router
comms ospfv3 router set Edit the OSPFv3 router
comms ospfv3 router delete Disable the OSPFv3 router
comms ospfv3 router show View the OSPFv3 router configuration
comms ip6 routing-table show Retrieve IPv6 Routing Table
comms ip6 ndp-table show Retrieve IPv6 NDP Table
comms ospfv3 circuit create Create an OSPFv3 circuit
comms ospfv3 circuit set Edit an OSPFv3 circuit
comms ospfv3 circuit delete Delete an OSPFv3 circuit
comms ospfv3 circuit show Retrieve one or ALL OSPFv3 circuits.
comms ip6 linklocal show Retrieve the IPV6 LinkLocal addresses for all interfaces.
comms ip6 gne create Defines this NE to be an IPV6 GNE.
comms ip6 gne delete Deletes the IPV6 GNE record. The NE is no longer tagged as being an IPV6
GNE.
comms ip6 gne show Retrieve an NE's IPV6 GNE designation.
comms inband-comms create Configure In-Band Comms Management Channel
comms inband-comms delete Delete In-Band Comms Management Channel
comms inband-comms show Retrieve settings of In-Band Comms Management Channels
comms ip-pktn create Provision an IP address for Packet Network services.
comms ip-pktn delete Delete an IP address for Packet Network services.
comms ip-pktn show Retrieve the IP addresses for Packet Network services.
comms gne-portfilter create Add a filter to drop packets on the GNE destined to a specified TCP/UDP port
on COLAN-X and/or COLAN-A
comms gne-portfilter delete Delete the GNE UDP/TCP drop filter assigned to the PORTFILTER-shelf-
index interface.
comms gne-portfilter show Retrieve the GNE UDP/TCP drop filter parameters assigned to the
PORTFILTER-shelf-index interface.
comms lldp set Enable/Disable LLDP
comms lldp show Retrieve the LLDP entries.
AID Descriptions
AID Type Format Values
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
Input Parameter Description
Parameter Value Description Notes
ipv4-server-state ON, OFF Turn the DHCP service
on the CRAFT LAN
port ON or OFF
(default is ON).
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
idle-timeout INT Idle timeout, in
(1-900 Default=180) seconds, for any
connection to the FTP
server.
server ENABLED, DISABLED Enable or disable the
FTP server (default is
DISABLED).
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
access ARP, NAT, OSPF, STATIC, Defined the DCN
PRIVATEIP access mechanism to
be used
config REDUNDANT, STANDALONE Defines the GNE
configuration
gne-group INT Specifies the Mandatory parameter
(1-255) redundancy group that if configuration is
the GNE belongs to for REDUNDANT and
master/backup Access is ARP,
negotiation otherwise it is not
applicable
primary YES, NO Defines the GNE as
being the preferred
MASTER.
subnet-name string Subnet name, range
up to 36 alphanumeric
and special characters
user-ftp-port INT User provisioned FTP Only valid when
(1-65535) port for NAT Access is NAT or
configuration PRIVATEIP, otherwise
it is not applicable
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
subnet-name string Subnet name, range
up to 36 alphanumeric
and special characters
user-ftp-port INT User provisioned FTP Only valid when
(1-65535) port for NAT Access is NAT or
configuration PRIVATEIP, otherwise
it is not applicable
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
grpc ON, OFF Disable or enable
access to the GRPC
service
grpcencoding ASCII ASCII Encoding type
PROTO PROTO Encoding type
JSON JSON Encoding type
https-state ON, OFF Disable or enable state
of the secure HTTP
protocol access
http-state ON, OFF Disable or enable state
of the regular HTTP
protocol access
idle-timeout INT Specify the REST
(1-900 Default=600) service idle time out
value (in seconds)
rest ON, OFF Disable or enable
access to the REST
service
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
state ON, OFF Disable or enable state
of the NETCONF
protocol
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
[2,2E]P[1]
port-rt1Ptp1
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
Syntax Definition
Parameter Attributes Description Notes
ocn M circuit aid
carrier M Choose which
overhead bytes are
used to carry DCC
(Section or Line).
ckt-default-metric M Circuit default metric Default is AID-
dependent.
l2-only M Level 2 Only
nps-override M Neighbour Protocols LAN_OSIONLY only
Supported Override valid for LAN AIDs
three-way-hs M Three-Way Handshake
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
ip-addr ipaddr IP address(IPv4) for The IP address must
( min len=0 max len=15 ) distribution specified be in the standard dot
by aid. notation, n.n.n.n,
0.0.0.0 indicates
"unnumbered"
leak-list-id OSPFRDLIST, STATICRDLIST Router list for
distribution
metric INT Metric for the 1-63
(1-63) distributed route
metric-type EXTERNAL, INTERNAL Metric type which
associate the metric
value of the distributed
route
netmask ipaddr Netmask for Must be in the
( min len=0 max len=15 ) distribution specified standard dot notation,
by aid. n.n.n.n
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
l1-priority INT LEVEL1 router priority.
(1-127 Default=64) Default=64.
l2-priority INT LEVEL2 router priority.
(1-127 Default=64) Default=64.
router-level LEVEL1, LEVEL2 Router level.
Default=LEVEL1.
route-summarisation ON, OFF Whether routes or
route summaries are
redistributed.
Default=ON.
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
SHELF SHELF-shelf SHELF-[0..992]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
Syntax Definition
Parameter Attributes Description Notes
ipcommsaid M aid
bcast-addr M Broadcast Must be in the
address(IPv4) for standard dot notation,
interface specified by n.n.n.n
aid.
carrier O Overhead bytes that
carry the DCC or
G.709 GCC.
def-ttl M Default Time To Live
(hops).
host-only O Host only mode.
ip-addr M IP address(IPv4) for Must be in the
interface specified by standard dot notation,
aid. n.n.n.n
net-domain O Network Domain.
netmask M Netmask for interface Must be in the
specified by aid. standard dot notation,
n.n.n.n
non-routing M Non-routing mode.
proxy-arp M Enable/disable Proxy
ARP Default = OFF.
Output Parameter Description
Parameter Value Description Notes
ipcommsaid ident aid
bcast-addr ipaddr Broadcast Must be in the
( min len=0 max len=15 ) address(IPv4) for standard dot notation,
interface specified by n.n.n.n
aid.
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
def-ttl INT Default Time To Live
(1-255 Default=90) (hops).
host-only OFF, ON Host only mode.
ip-addr ipaddr IP address(IPv4) for Must be in the
( min len=0 max len=15 ) interface specified by standard dot notation,
aid. n.n.n.n
net-domain MCN Management
Communications
Network
SONETCP Signaling
Communications
Network for SONET
Control Plane
OTNCP Signaling
Communications
Network for OTN
Control Plane
ENCRYP Encryption
Communications
Network
WSC LAN Wayside Channel
netmask ipaddr Netmask for interface Must be in the
( min len=0 max len=15 ) specified by aid. standard dot notation,
n.n.n.n
non-routing OFF, ON Non-routing mode.
proxy-arp OFF, ON Enable/disable Proxy
ARP Default = OFF.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
dcn-ip ipaddr IP address(IPv4) must The IP address must
( min len=0 max len=15 ) be in the standard dot be in the standard dot
notation, n.n.n.n notation, n.n.n.n .
0.0.0.0 is not
acceptable
prime YES, NO Indicates whether
RNEIP is the IP
address to be used for
mapping of incoming
packets (should
generally be the
circuitless IP)
rne-ip ipaddr IP address(IPv4) must Must be in the
( min len=0 max len=15 ) be in the standard dot standard dot notation,
notation, n.n.n.n n.n.n.n . 0.0.0.0 is not
acceptable. IP
addresses local to this
SHELF are not
allowed.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
dcn-ip ipaddr IP address(IPv4) must The IP address must
( min len=0 max len=15 ) be in the standard dot be in the standard dot
notation, n.n.n.n notation, n.n.n.n .
0.0.0.0 is not
acceptable
rne-ip ipaddr IP address(IPv4) must Must be in the
( min len=0 max len=15 ) be in the standard dot standard dot notation,
notation, n.n.n.n n.n.n.n . 0.0.0.0 is not
acceptable
Top of Comms Section
comms ip-nat show
Description: Retrieve IPNAT
CLI command: comms ip-nat show
Security Level: 1
Input syntax comms ip-nat show [aid]
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
dcn-ip M IP address(IPv4) must The IP address must
be in the standard dot be in the standard dot
notation, n.n.n.n notation, n.n.n.n .
0.0.0.0 is not
acceptable
prime O Indicates whether
RNEIP is the IP
address to be used for
mapping of incoming
packets (should
generally be the
circuitless IP)
rne-ip M IP address(IPv4) must Must be in the
be in the standard dot standard dot notation,
notation, n.n.n.n n.n.n.n . 0.0.0.0 is not
acceptable
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
Input Parameter Description
Parameter Value Description Notes
anctrl AUTO Auto Negotiation with
auto control
MASTER Auto Negotiation with
master control
SLAVE Auto Negotiation with
slave control
config FD100BT, FD1000BT, AUTO Port Duplex and
Speed
netdomain MCN Management
Communications
Network
PKTN Packet Network
Provider Domain
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-port LAN-[0..992]-[41..42]
T12/T24)
Input Parameter Description
Parameter Value Description Notes
anctrl AUTO Auto Negotiation with
auto control
MASTER Auto Negotiation with
master control
SLAVE Auto Negotiation with
slave control
config FD100BT, FD1000BT, AUTO Port Duplex and
Speed
port ENABLED, DISABLED Enable or disable the
LAN port
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
AID Descriptions
AID Type Format Values
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
Syntax Definition
Parameter Attributes Description Notes
ocn M aid
carrier M Choose which
overhead bytes are
used to carry DCC
(Section, Line, GCC0,
GCC1, GCC2 or EXT).
fcs-mode O HDLC FCS MODE.
l2-info O LAPD Frame Size
l2-side O LAPD: the role of the
local node, network or
user. The default value
is Auto. The local node
attempts to establish a
connection with the far
end by toggling its role
between network and
user in a random
pattern. Setting this
parameter to auto
simplifies the setup of
the link since the
nodes decide which
node is user and which
is network. It does not
matter which node has
which role, as long as
the two connecting
nodes have opposite
roles.
net-domain O Network Domain.
oper-carrier M Display which
overhead bytes are
used to carry DCC
(Section, Line,
DISCONNECTED,
GCC0, GCC1, GCC2
or EXT).
oper-l2side O LAPD: the role of the
local node, network or
user.
protocol M Protocol
transparent-connect O TRANSP:
transparency
connection mate AID
Output Parameter Description
Parameter Value Description Notes
ocn ident aid
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
fcs-mode 16BIT, 32BIT HDLC FCS MODE.
l2-info INT LAPD Frame Size
(512-1492)
l2-side USER, NETWORK, AUTO LAPD: the role of the
local node, network or
user. The default value
is Auto. The local node
attempts to establish a
connection with the far
end by toggling its role
between network and
user in a random
pattern. Setting this
parameter to auto
simplifies the setup of
the link since the
nodes decide which
node is user and which
is network. It does not
matter which node has
which role, as long as
the two connecting
nodes have opposite
roles.
net-domain MCN Management
Communications
Network
SONETCP Signaling
Communications
Network for SONET
Control Plane
OTNCP Signaling
Communications
Network for OTN
Control Plane
ENCRYP Encryption
Communications
Network
WSC LAN Wayside Channel
oper-carrier SECTION, LINE, Display which
DISCONNECTED, GCC0, GCC1, overhead bytes are
GCC2, EXT used to carry DCC
(Section, Line,
DISCONNECTED,
GCC0, GCC1, GCC2
or EXT).
oper-l2side USER, NETWORK, LAPD: the role of the
DISCONNECTED local node, network or
user.
protocol LAPD, PPP, NDP, TRANSP, Protocol
ETHERNET
transparent-connect ident TRANSP:
transparency
connection mate AID
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
nat-base-port INT Specifies the base This applies to
(1024-65279) UDP/TCP port value Redundant NAT and
dynamically allocated Private IP GNEs. If not
for connections flows specified, the current
managed by NAT value is not changed.
services. If never configured, the
NATBASEPORT to default is 50000.
NATBASEPORT+NAT
NUMPORT defines the
range that NAT uses.
nat-num-port INT Specifies the number This applies to
(256-1024) of UDP/TCP ports Redundant NAT and
dynamically allocated Private IP GNEs. If not
for connections flows specified, the current
managed by NAT value is not changed.
services. If never configured, the
NATBASEPORT to default is 512.
NATBASEPORT+NAT
NUMPORT defines the
range that NAT uses.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
rne-tid string The Remote NE The validation for the
( min len=1 max len=20 ) Target IDentifier is the name is identical to the
node name / system SET-SID sid
identifier (SID) of a parameter.
remote Network
Element. The name
can include any
combination of upper
and lower case letters,
numbers, or special
characters (lowercase
and special characters
must be quoted). If
unquoted, the name
must start with a letter.
If unquoted, the only
permitted special
character is a hyphen.
The name cannot
include the following
characters: backslash,
space, double-quote,
colon, semicolon,
ampersand, greater
than, less than, or
comma.
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-slot LAN-[0..992]-[41..42]
T12/T24)
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
SHELF SHELF-shelf SHELF-[0..992]
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
area OFF, NSSA, STUB Area. Default=OFF.
area-def-cost INT Area Default Cost.
(1-16777215 Default=1)
auth-type NULL, SIMPLE, MD5 This field indicates the
authentication type of
the OSPF. NULL
means no
authentication.
SIMPLE means simple
authentication. MD5
means MD5
authentication.
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
cost INT The OSPF circuit cost. For Shelf the cost is 0,
(0-65535) otherwise the cost
range is 1 to 65535(for
T-series, SP2/SPAP2)
or 1 to 65534(for CPL,
SP1/SPAP1). Default
cost for GCC is 75, for
LDCC is 174 and for
SDCC is 520.
Otherwise default
cost(for Ethernet) is
10.
dead-invl INT Dead interval.
(1-65535 Default=40)
hello-invl INT Hello interval.
(1-65535 Default=10)
id1 INT An integer key ID from
(0-255 Default=0) 0 to 255 to be used for
OSPF MD5 password
authentication on this
circuit.
id2 INT An integer key ID from
(0-255 Default=1) 0 to 255 to be used for
OSPF MD5 password
authentication on this
circuit.
key1 string A character string from CLI will prompt for the
( min len=1 max len=16 ) 1-16 characters to be user password with
used for OSPF MD5 echo disabled after the
password command is entered.
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
key2 string A character string from CLI will prompt for the
( min len=1 max len=16 ) 1-16 characters to be user password with
used for OSPF MD5 echo disabled after the
password command is entered.
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
net-area ipaddr OSPF Network Area Must be in the
( min len=0 max len=15 ) standard dot notation,
n.n.n.n
opaque ON, OFF Support for Defaults to OFF for all
transmission/reception COLAN and craft
of OSPF opaque LSAs interface. Defaults to
on a given interface. ON for all other
interface.
passive ON, OFF PASSIVE ON/OFF
disables/enables the
ability to raise the
OSPF Adjacency Loss
alarm against the
circuit.
password string A character string from CLI will prompt for the
( min len=1 max len=8 ) 1-8 characters to be user password with
used for OSPF simple echo disabled after the
password command is entered.
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
primary-area ON, OFF Primary area is OFF
can have multi netarea
provision on the same
AID
priority INT Priority.
(0-255 Default=1)
retrans-invl INT Retransmit interval.
(1-3600 Default=5)
trans-delay INT Transmit Delay.
(1-3600 Default=1)
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-slot LAN-[0..992]-[41..42]
T12/T24)
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
SHELF SHELF-shelf SHELF-[0..992]
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
area OFF, NSSA, STUB Area. Default=OFF.
area-def-cost INT Area Default Cost.
(1-16777215 Default=1)
auth-type NULL, SIMPLE, MD5 This field indicates the
authentication type of
the OSPF. NULL
means no
authentication.
SIMPLE means simple
authentication. MD5
means MD5
authentication.
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
cost INT The OSPF circuit cost. For Shelf the cost is 0,
(0-65535) otherwise the cost
range is 1 to 65535(for
T-series, SP2/SPAP2)
or 1 to 65534(for CPL,
SP1/SPAP1). Default
cost for GCC is 75, for
LDCC is 174 and for
SDCC is 520.
Otherwise default
cost(for Ethernet) is
10.
dead-invl INT Dead interval.
(1-65535 Default=40)
hello-invl INT Hello interval.
(1-65535 Default=10)
id1 INT An integer key ID from
(0-255 Default=0) 0 to 255 to be used for
OSPF MD5 password
authentication on this
circuit.
id2 INT An integer key ID from
(0-255 Default=1) 0 to 255 to be used for
OSPF MD5 password
authentication on this
circuit.
key1 string A character string from
( min len=1 max len=16 ) 1-16 characters to be
used for OSPF MD5
password
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
key2 string A character string from
( min len=1 max len=16 ) 1-16 characters to be
used for OSPF MD5
password
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
net-area ipaddr OSPF Network Area Must be in the
( min len=0 max len=15 ) standard dot notation,
n.n.n.n
opaque ON, OFF Support for Defaults to OFF for all
transmission/reception COLAN and craft
of OSPF opaque LSAs interface. Defaults to
on a given interface. ON for all other
interface.
passive ON, OFF PASSIVE ON/OFF
disables/enables the
ability to raise the
OSPF Adjacency Loss
alarm against the
circuit.
password string A character string from
( min len=1 max len=8 ) 1-8 characters to be
used for OSPF simple
password
authentication on this
circuit. Any
combination of upper,
lower, numbers or
special characters may
be used.
primary-area ON, OFF Primary area is OFF
can have multi netarea
provision on the same
AID
priority INT Priority.
(0-255 Default=1)
retrans-invl INT Retransmit interval.
(1-3600 Default=5)
trans-delay INT Transmit Delay.
(1-3600 Default=1)
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-slot LAN-[0..992]-[41..42]
T12/T24)
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
SHELF SHELF-shelf SHELF-[0..992]
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
net-area ipaddr OSPF Network Area Must be in the
( min len=0 max len=15 ) standard dot notation,
n.n.n.n
primary-area ON, OFF Primary area is OFF
can have multi netarea
provision on the same
AID
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
CRAFT LAN (6500- LAN-shelf-slot LAN-[0..992]-[41..42]
T12/T24)
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC (6500-T24) OSC-shelf-slot-port OSC-[0..992]-[1..24]-[2]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
SHELF SHELF-shelf SHELF-[0..992]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
Syntax Definition
Parameter Attributes Description Notes
aid M circuit aid
adj-state M This field indicates the
OSPF adj state.
carrier M Choose which
overhead bytes are
used to carry
DCC/GCC.
nbr-ip M neigbour IP Must be in the
address(IPv4) standard dot notation,
n.n.n.n
nbr-routerid M neigbour router ID Must be in the
standard dot notation,
n.n.n.n
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
ip-addr ipaddr The IP address(IPv4) The IP address must
( min len=0 max len=15 ) to be assigned be in the standard dot
notation, n.n.n.n,
0.0.0.0 indicates
"unnumbered"
leak-list-id ISISRDLIST, STATICRDLIST Router list for
distribution.
metric INT Metric for the 1-65535
(1-65535) distributed route
metric-type INTERNAL, EXTERNAL Metric type which EXTERNAL,
associate the metric INTERNAL
value of the distributed
route. Default=Internal
netmask ipaddr Netmask for static Must be in the
( min len=0 max len=15 ) route specified by aid. standard dot notation,
n.n.n.n
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
abr RFC3509, RFC2328COMPATIBLE Used to configure
ABR.
asbr ON, OFF Used to configure NE
as Autonomous
System Border Router.
Default=OFF.
opaque-filter ALL, LAN, OFF Used to configure NE
with Opaque LSA
Flooding Control.
Default=OFF.
rfc1583-capable ON, OFF Used to configure
RFC1583
compatibility.
Default=ON.
router-id ipaddr Router ID, in the Must be in the format
( min len=0 max len=15 ) format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255] except
[0,255], except 0.0.0.0 0.0.0.0
route-summarisation ON, OFF Whether routes or
route summaries are
redistributed.
Default=ON.
shelf-rd ON, OFF Used to configure NE
with Shelf IP Re-
distribution.
Default=OFF.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
abr RFC3509, RFC2328COMPATIBLE Used to configure
ABR.
asbr ON, OFF Used to configure NE
as Autonomous
System Border Router.
opaque-filter ALL, LAN, OFF Used to configure NE
with Opaque LSA
Flooding Control.
rfc1583-capable ON, OFF Used to configure
RFC1583
compatibility.
Default=ON.
router-id ipaddr Router ID, in the Must be in the format
( min len=0 max len=15 ) format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255] except
[0,255], except 0.0.0.0 0.0.0.0
route-summarisation ON, OFF Whether routes or
route summaries are
redistributed.
shelf-rd ON, OFF Used to configure NE
with Shelf IP Re-
distribution.
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
portSsubport [1..40]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-[1..40]-
port-rt1Ptp1 [2,2E]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..2]-
portSsubport-rt1Ptp1 [1..40]S[1..4]-[2,2E]P[1]
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
carrier M Choose which Only GCC0 will be
overhead bytes are supported in 6500
used to carry G709 R1.5
GCC bytes.
heartbeat M PPP Heartbeat
ip-hdr-compression M IP Header
Compression
local-secret M PPP Local Secret
magic-num M PPP Magic Number
Support
max-receive-unit M PPP Frame Size
oper-mru M Negotiated PPP Frame
Size
peer-ip M IP addresses(IPv4) to The IP address must
assign to remote end. be in the standard dot
notation, n.n.n.n
preferred-frame- M PPP Preferred Frame
checksum Checksum
remote-secret M PPP Remote Secret
security M PPP Security
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
dcn-port INT Indicates the public
(1-65535) protocol port that is
mapped to a specific
RNEIP and
RNEPORT.
proto TCP, UDP Indicates the protocol
to be translated from
public to private.
rne-ip ipaddr This indicates what IP Must be in the
( min len=0 max len=15 ) address(IPv4) the standard dot notation
public protocol port is n.n.n.n, 0.0.0.0 is not
mapped to. acceptable. The RNE
shelf address should
be specified. RNEIP
addresses of
169.254.0.n are not
allowed. IP Addresses
local to this SHELF are
not allowed.
rne-port INT The private protocol
(1-65535) port that DCNPORT is
to be mapped to.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
dcn-port INT Indicates the public
(1-65535) protocol port that is
mapped to a specific
RNEIP and
RNEPORT.
proto TCP, UDP Indicates the protocol
to be translated from
public to private.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
name string NE Name (TID)
neid ident NE ID
sysid ident NE System ID
Syntax Definition
Parameter Attributes Description Notes
shelf O shelf aid
id M ID. Empty for Express.
sitemgr M Site Manager Support
(Y or N). Always Y for
6500. N for CPL.
systemid M System ID
tid M NE TID (presented as
an inner string i.e.
\"tid\")
type M Eight hexadecimal Examples: 00011600
digits. Digits 1+2: 00 - for 6500, 00011700 for
Known Ciena CPL, 00011B00 for
Equipment, 01 - 5410, 00011C00 for
Unknown Ciena 5430, 00011D00 for
Equipment, 11 - Other 6500-T, 00013000 for
Vendor. Digits 3+4: 00 Waveserver.
- OPC, 01 - anything
other than OPC; Digits
5+6: for OPC: status
(active/inactive,
primary/backup),
otherwise: type (16 for
6500, 17 for CPL, 1B
for 5410, 1C for 5430);
Digits 7+8: 00 - SP, 01
- NP (Express only).
Output Parameter Description
Parameter Value Description Notes
shelf ident shelf aid
id INT ID. Empty for Express.
sitemgr YES
NO
systemid ident System ID
tid string NE TID (presented as
an inner string i.e.
\"tid\")
type ident Eight hexadecimal Examples: 00011600
digits. Digits 1+2: 00 - for 6500, 00011700 for
Known Ciena CPL, 00011B00 for
Equipment, 01 - 5410, 00011C00 for
Unknown Ciena 5430, 00011D00 for
Equipment, 11 - Other 6500-T, 00013000 for
Vendor. Digits 3+4: 00 Waveserver.
- OPC, 01 - anything
other than OPC; Digits
5+6: for OPC: status
(active/inactive,
primary/backup),
otherwise: type (16 for
6500, 17 for CPL, 1B
for 5410, 1C for 5430);
Digits 7+8: 00 - SP, 01
- NP (Express only).
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
common-name string Common Name
( min len=1 max len=64 )
country string Country
( min len=1 max len=2 )
key-size 1024, 2048, 4096 SSL server key size
(1024)
key-type RSA Only RSA keytype is
supported
locality string City or Locality
( min len=1 max len=128 )
org string Organization
( min len=1 max len=64 )
org-unit string Organizational Unit
( min len=1 max len=64 )
state string State or Province
( min len=1 max len=128 )
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
idle-timeout INT Idle timeout, in
(0-99 Default=30) minutes, for any
connection to the
TELNET server.
max-sessions INT Maximum number of
(1-18 Default=18) simultaneous sessions
that the TELNET
server will accept.
server-state ENABLED, DISABLED Enable or disable the
TELNET server
(default is ENABLED).
SSH server must be
enabled in order to
disable TELNET
server
AID Descriptions
AID Type Format Values
RLA WSC (6500-T12) WSC-shelf-slot-port WSC-[0..992]-[1..12]-[1]
RLA WSC (6500-T24) WSC-shelf-slot-port WSC-[0..992]-[1..24]-[1]
Input Parameter Description
Parameter Value Description Notes
config HD10BT, HD100BT, FD10BT, Port Duplex and Error message will be
FD100BT, AUTO Speed returned if
corresponding OSC
card and facility are
not provisioned
AID Descriptions
AID Type Format Values
RLA WSC (6500-T12) WSC-shelf-slot-port WSC-[0..992]-[1..12]-[1]
RLA WSC (6500-T24) WSC-shelf-slot-port WSC-[0..992]-[1..24]-[1]
Input Parameter Description
Parameter Value Description Notes
config HD10BT, HD100BT, FD10BT, Port Duplex and
FD100BT, AUTO Speed
WSC-[0..992]-[1..12]-ALL
WSC-[0..992]-ALL
RLA WSC (6500-T24) WSC-shelf-slot-port WSC-[0..992]-[1..24]-[1]
WSC-[0..992]-[1..24]-ALL
WSC-[0..992]-ALL
WSC on all slots WSC-shelf-ALL WSC-[0..992]-ALL
WSC-[0..992]-ALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
lan-port M aid
wsc-port M aid
config M Configured Port
Duplex and Speed
oper-config M Negotiated Port
Duplex and Speed
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
priority INT Priority. Can be 0 to
(0-255) 255.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
list EDIT ACL edit list
COMMIT ACL commit list
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
action M The action of the rule.
circuit M L The interface to which Example of circuit
the rule applies. interface: ILAN-Shelf-
IN/OUT , COLAN-
Shelf-X/A
ip-addr M The IP address(IPv4) Must be in the
standard dot notation,
n.n.n.n.
netmask M The IP mask Must be in the
standard dot notation,
n.n.n.n.
priority M Priority. The priority can be 0 to
255.
Output Parameter Description
Parameter Value Description Notes
shelf ident aid
action DENY Action to be denied
ALLOW Action to be allowed
circuit COLAN COLAN- COLAN- The interface to which Example of circuit
(6500- shelf- [0..992]- the rule applies. interface: ILAN-Shelf-
T12/T24) port [A,X] IN/OUT , COLAN-
Shelf-X/A
ILAN ILAN- ILAN-
(6500- shelf- [0..992]-
T12/T24) port [IN1,OUT1
,IN2,OUT2
,IN3,OUT3
]
ip-addr ipaddr The IP address(IPv4) Must be in the
( min len=7 max len=15 ) standard dot notation,
n.n.n.n.
netmask ipaddr The IP mask Must be in the
( min len=7 max len=15 ) standard dot notation,
n.n.n.n.
priority INT Priority. The priority can be 0 to
(0-255) 255.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
action DENY Action to be denied
ALLOW Action to be allowed
dest-end-port INT Specifies end at which
(0-65535) destination port
dest-ip-addr string IP addr
( min len=0 max len=46 )
dest-prefix INT Set the IP network
(0-128) prefix
dest-start-port INT Specifies start from
(0-65535) which destination port
ip-version NONE, IPV4, IPV6 IP verson
priority INT Priority, 0 to 255 where
(0-255) 0 is the highest priority.
proto NONE, TCP, UDP Specifies which
protocol, TCP or UDP
src-end-port INT Specifies end at which
(0-65535) source port
src-ip-addr string IP addr
( min len=0 max len=46 )
src-prefix INT Set the IP network
(0-128) prefix
src-start-port INT Specifies start from
(0-65535) which source port
Top of Comms Section
comms pktn acl-list delete
Description: Used to delete an PKTN ACL entry
CLI command: comms pktn acl-list delete
Security Level: 4
Input syntax comms pktn acl-list delete <aid> priority <Value>
Syntax Definition
Parameter Attributes Description Notes
priority M Priority. Can be 0 to
255.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
priority INT Priority. Can be 0 to
(0-255) 255.
Syntax Definition
Parameter Attributes Description Notes
shelf M aid
action M The action of the rule.
dest-ip-addr M IP addr
dest-prefix M Set the IP network
prefix
dst-end-port M Specifies end at which
destination port
dst-start-port M Specifies start from
which destination port
ip-version M IP verson
priority M Priority. The priority can be 0 to
255.
proto O Specifies which
protocol, TCP or UDP
src-end-port M Specifies end at which
source port
src-ip-addr M IP addr
src-prefix M Set the IP network
prefix
src-start-port M Specifies start from
which source port
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
service DISABLE, ENABLE, The status of the ACL. server is
TEMPORARY disabled/temporary
enabled/enabled
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
admin-state OFF Turn the feature off at
a shelf level
ON Turn the feature on at
a shelf level
ip-addr string The NODEID (an IP The address MUST in
( min len=0 max len=15 ) V4 address). the standard dot
notation, n.n.n.n.
0.0.0.0 is not allowed.
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-[1..40]
port
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..2]-
[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-[1..40]
port
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..2]-
portSsubport [1..40]S[1..4]
Syntax Definition
Parameter Attributes Description Notes
ocn M aid
carrier M Choose which
overhead bytes are
used to carry G.709
GCC. NOTE:
Mandatory parameter
with optical AIDs.
AID Descriptions
AID Type Format Values
Comms IPADDRESS entry IPADDR-shelf-index IPADDR-[0..992]-[1..256]
Input Parameter Description
Parameter Value Description Notes
ip-addr string IP address. IPv6
( min len=0 max len=46 ) address MUST be
quoted.
prefix INT Set the IP network
(0-128) prefix
AID Descriptions
AID Type Format Values
Comms static route entry STATICRT-shelf-index STATICRT-[0..992]-[1..80]
Input Parameter Description
Parameter Value Description Notes
cost INT Cost: [1-65535] COST range = 1-
(0-65535) 65535
description string 0..64 chars to identify A character string from
the Static Route 1-64 characters used
to label the IP Static
Route
distributed-route-metric- INTERNAL Re-distribute the static
type route as an internal
route
EXTERNAL Re-distribute the static
route as an external
route
ip-addr string IP Address, IPv6 The IPv6 address
( min len=0 max len=46 ) address must be must be quoted, and
quoted must be in IPv6
address format.
next-hop string IP Address, IPv6 The IPv6 address
( min len=0 max len=46 ) address must be must be quoted, and
quoted must be in IPv6
address format.
prefix INT IP network prefix
(0-128)
redistribut OFF Set static route Re-
distribution to OFF
OSPFV3 Re-distribute static
route to OSPFv3
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
admin-state ON Enable the feature at a
shelf level
OFF Disable the feature at
a shelf level
config AUTO Automatically re- The SCOPEID
provision the provisioning will
SCOPEID. automatically be
updated when the
SiteId is re-
provisioned.
MANUAL Manualy provision the The SCOPEID
SCOPEID to one fixed provisioning will
value. remain fixed to the
provisioned value.
scopeid INT Specifies the scope of Default value will be
(0-65535) the AR/TR records. the SiteId.
AID Descriptions
AID Type Format Values
Comms NDPROXY IPv6 NDPROXY-shelf-index NDPROXY-[0..992]-[1..150]
ADDRESS entry
Input Parameter Description
Parameter Value Description Notes
circuit COLAN COLAN- COLAN- Circuit on which The circuit on which
(6500- shelf- [0..992]- IPADDR is PROXYed IPADDR is PROXYed
T12/T24) port [A,X]
ILAN ILAN- ILAN-
(6500- shelf- [0..992]-
T12/T24) port [IN1,OUT1
,IN2,OUT2
,IN3,OUT3
]
ip-addr string IPv6 address, must be The IPv6 address
( min len=0 max len=46 ) quoted must be quoted
AID Descriptions
AID Type Format Values
Comms NDPROXY IPv6 NDPROXY-shelf-index NDPROXY-[0..992]-[1..150]
ADDRESS entry
Input Parameter Description
Parameter Value Description Notes
circuit COLAN COLAN- COLAN- Circuit on which The circuit on which
IPADDR is PROXYed IPADDR is PROXYed
(6500- shelf- [0..992]-
T12/T24) port [A,X]
ILAN ILAN- ILAN-
(6500- shelf- [0..992]-
T12/T24) port [IN1,OUT1
,IN2,OUT2
,IN3,OUT3
]
ip-addr string IPv6 address, must be The IPv6 address
( min len=0 max len=46 ) quoted must be quoted.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
abr RFC3509, RFC2328 Used to configure
ABR.
router-id ipaddr Router ID, in the Must be in the format
format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255] except
[0,255], except 0.0.0.0 0.0.0.0
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
abr RFC3509, RFC2328 Used to configure
ABR.
router-id ipaddr Router ID, in the Must be in the format
format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255] except
[0,255], except 0.0.0.0 0.0.0.0
AID Descriptions
AID Type Format Values
OSPFV3 Circuit entry OSPFV3-shelf-index OSPFV3-[0..992]-[1..256]
Input Parameter Description
Parameter Value Description Notes
carrier SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
circuit COLAN COLAN- COLAN- Interface The interface to which
(6500- shelf- [0..992]- the OSPFv3 Circuit is
T12/T24) port [A,X] assigned
ILAN ILAN- ILAN-
(6500- shelf- [0..992]-
T12/T24) port [IN1,OUT1
,IN2,OUT2
,IN3,OUT3
]
CRAFT LAN- LAN-
LAN shelf- [0..992]-
(6500- slot [41..42]
T12/T24)
OSC OSC- OSC-
(6500- shelf- [0..992]-
T12) slot- [1..12]-[2]
port
OSC OSC- OSC-
(6500- shelf- [0..992]-
T24) slot- [1..24]-[2]
port
OSC OSC- OSC-
(6500- shelf- [0..992]-
T12) slot- [1..12]-[2]
port
OSC OSC- OSC-
(6500- shelf- [0..992]-
T24) slot- [1..24]-[2]
port
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4]P
rt1Ptp1
[1]
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-[1..40]-
[2,2E]P[1]
port-
rt1Ptp1
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4]P
rt1Ptp1
[1]
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-[1..40]-
[2,2E]P[1]
port-
rt1Ptp1
ODU TTP ODUTTP- ODUTTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4]P
rt1Ptp1
[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-[1..40]-
[2,2E]P[1]
port-
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1 [2,2E,3,4]P
[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-[1..40]-
[2,2E]P[1]
port-
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]-
port-
[2,2E]P[1]
rt1Ptp1
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port [1..40]
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]
port
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-[1..40]
port
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]
port
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port [1..40]
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
port 4]
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-[1..40]
port
OTU OTUTTP- OTUTTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 2]-
[1..40]S[1..
portSsub
4]
port
SHELF SHELF- SHELF-
shelf [0..992]
cost INT The OSPF circuit cost. For Shelf the cost is 0,
(0-65535) otherwise the cost
range is 1 to 65535.
Default costs: GCC is
75, LDCC is 174,
SDCC is 520,
otherwise 10
dead-interval INT Dead interval: [1,
(1-65535 Default=40) 65535]
hello-interval INT Hello interval: [1,
(1-65535 Default=10) 65535]
instance-id INT Instance ID: [0, 255]
(0-255)
net-area ipaddr OSPFv3 network area, Must be in the format
in the format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255]
[0,255]
passive ON, OFF PASSIVE ON/OFF
disables/enables the
ability to raise the
OSPF Adjacency Loss
alarm against the
circuit
primary-area ON, OFF PRIMARY AREA
ON/OFF
enables/disables
Interface participating
to OSPFv3 Primary
Area
priority INT Priority: [0, 255]
(0-255 Default=1)
retransmit-interval INT Retransmit interval: [1,
(1-1800 Default=5) 1800]
trans-delay INT Transmit delay: [1,
(1-1800 Default=1) 1800]
Top of Comms Section
comms ospfv3 circuit set
Description: Edit an OSPFv3 circuit
CLI command: comms ospfv3 circuit set
Security Level: 3
Input syntax comms ospfv3 circuit set <aid> [cost <Value>][dead-interval <Value>]
[hello-interval <Value>][instance-id <Value>][net-area <Value>]
[passive <Value>][priority <Value>][retransmit-interval <Value>]
[trans-delay <Value>]
Syntax Definition
Parameter Attributes Description Notes
cost O The OSPF circuit cost. For Shelf the cost is 0,
otherwise the cost
range is 1 to 65535.
Default costs: GCC is
75, LDCC is 174,
SDCC is 520,
otherwise 10
dead-interval O Dead interval: [1,
65535]
hello-interval O Hello interval: [1,
65535]
instance-id O Instance ID: [0, 255]
net-area O OSPFv3 network area, Must be in the format
in the format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255]
[0,255]
passive O PASSIVE ON/OFF
disables/enables the
ability to raise the
OSPF Adjacency Loss
alarm against the
circuit
priority O Priority: [0, 255]
retransmit-interval O Retransmit interval: [1,
3600]
trans-delay O Transmit delay: [1,
3600]
AID Descriptions
AID Type Format Values
OSPFV3 Circuit entry OSPFV3-shelf-index OSPFV3-[0..992]-[1..256]
Input Parameter Description
Parameter Value Description Notes
cost INT The OSPF circuit cost. For Shelf the cost is 0,
(0-65535) otherwise the cost
range is 1 to 65535.
Default costs: GCC is
75, LDCC is 174,
SDCC is 520,
otherwise 10
dead-interval INT Dead interval: [1,
(1-65535 Default=40) 65535]
hello-interval INT Hello interval: [1,
(1-65535 Default=10) 65535]
instance-id INT Instance ID: [0, 255]
(0-255)
net-area ipaddr OSPFv3 network area, Must be in the format
in the format of IPv4 of IPv4 address:
address: a.b.c.d a.b.c.d [0,255]
[0,255]
passive ON, OFF PASSIVE ON/OFF
disables/enables the
ability to raise the
OSPF Adjacency Loss
alarm against the
circuit
priority INT Priority: [0, 255]
(0-255 Default=1)
retransmit-interval INT Retransmit interval: [1,
(1-1800 Default=5) 3600]
trans-delay INT Transmit delay: [1,
(1-1800 Default=1) 3600]
AID Descriptions
AID Type Format Values
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
netdomain MCN Management
Communications
Network
PKTN Packet Network
Provider Domain
AID Descriptions
AID Type Format Values
In-Band Comms IBC-shelf-instance IBC-[0..992]-[1..10]
Management AID
Input Parameter Description
Parameter Value Description Notes
ip-pktn-addr string IP address(IPv4) in Only IPv4 is
( min len=0 max len=15 ) dotted format. supported.
ip-pktn-gateway string GATEWAY IP address Only IPv4 is
( min len=0 max len=15 ) in dotted format. supported.
ip-pktn-prefix INT IP network prefix
(8-32)
ip-pktn-role CONTROL_PLANE Control Plane
DEVICE_MGMT Device Management
LOOPBACK Loopback
AID Descriptions
AID Type Format Values
Comms PORTFILTER PORTFILTER-shelf-index PORTFILTER-[0..992]-[1..10]
entry
Input Parameter Description
Parameter Value Description Notes
accesscolana ON, OFF Specify the GNE Defaults to OFF for
access interface for COLAN-A
COLAN-A.
accesscolanx ON, OFF Specify the GNE Defaults to ON for
access interface for COLAN-X
COLAN-X.
dropport INT Specifies the Both PROTO and
(0-65535) destination port for DROPPORT must be
which packets will be specified. There are no
dropped (0-65535) defaults.
proto TCP, UDP Specifies which Both PROTO and
protocol (TCP or UDP) DROPPORT must be
the filter is applicable specified. There are no
to. defaults.
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
Input Parameter Description
Parameter Value Description Notes
SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
service ENABLED, DISABLED LLDP service status
Top of Comms Section
comms lldp show
Description: Retrieve the LLDP entries.
CLI command: comms lldp show
Security Level: 1
Input syntax comms lldp show [aid] []
Syntax Definition
Parameter Attributes Description Notes
O Specifies the overhead
bytes that carry the
Data Communications
Channel (e.g., GCC0)
on optical interface.
AID Descriptions
AID Type Format Values
COLAN (6500-T12/T24) COLAN-shelf-port COLAN-[0..992]-[A,X]
ILAN (6500-T12/T24) ILAN-shelf-port ILAN-[0..992]-
[IN1,OUT1,IN2,OUT2,IN3,OUT3]
Input Parameter Description
Parameter Value Description Notes
SECTION Section
LINE Line
GCC0 General
Communication
Channel 0
GCC1 General
Communication
Channel 1
GCC2 General
Communication
Channel 2
EXT Extended
Communication
Channel
Syntax Definition
Parameter Attributes Description Notes
aid M aid
O Specifies the overhead
bytes that carry the
Data
Commmunications
Channel (e.g., GCC0)
on optical interface
chassisId-component O ChassisId Component
chassisId-if-alias O ChassisId If Alias
chassisId-if-name O ChassisId If Name
chassisId-local O ChassisId Local
chassisId-mac-addr O CHASSISID MAC
Address
chassisId-network-addr O ChassisId Network
Addr
chassisId-port- O ChassisId Port
component Component
chassis-id-subtype M LLDP chassis ID
subtype
enable-capability O Enable Capability
lldp-ttl M LLDP TTL
management-addr- O Management Addr
subtype subtype
management-ipaddr O Management IP addr
management-oid O Management OID
mgmt-inf-num O Management Interface
Number
mgmt-inf-num-subtype O Management Interface
Number Subtype
organization O Organization
port-description O Port Description
portId-agent-circuit-ID O PortId Agent Circuit ID
portId-component O PortId Component
portId-if-alias O PortId If Alias
portId-if-name O PortId If Name
portId-local O PortId Local
portId-mac-addr O PortID MAC Address
portId-network-addr O PortId Network Addr
port-id-subtype M LLDP Port ID subtype
service M LLDP service status
src-mac-addr M MAC Address
system-capability O System Capability
system-description O System Description
system-name O System Name
Diagnostic
diagnostic lamp test operate Test Lamp. Tests the LEDs on the shelf associated with the specified AID.
diagnostic led show Retrieve LED : Retrieves LED states from the shelf associated with the
specified AID.
diagnostic equipment diagnose Diagnose Equipment: Instructs a Network Element to initiate a diagnostic
routine on one or more equipment units in the Network Element.
diagnostic lamp flash operate Flash Lamps. Flash the LEDs on the shelf associated with the specified AID.
debuglog collect Retrieve Log : Collect debug logs from the specified shelf/slots.
debuglog download Save Log : (S)FTP collected debug logs off the network element.
debuglog cancel Cancel Log : Cancel log collection.
debuglog collect-status show Log Collection Status: Show the status of the most recent collection.
debuglog download-status show Log Download Status: Show the status of the most recent log download.
diagnostic dbfrz operate Operate Database Freeze: This command is used to block all the
provisioning request
AID Descriptions
AID Type Format Values
Equipment Slots (6500- SLOT-shelf-slot SLOT-[0..992]-
T12) [1..12,31..34,40..42,51..53]
Equipment Slots (6500- SLOT-shelf-slot SLOT-[0..992]-
T24) [1..24,31..39,40..42,51..55]
Equipment Slots (6500- SLOT-shelf-slot SLOT-[0..992]-[1..12,40..42,51..52]
T12P)
LEDs on Ports (6500-T12) SLOT-shelf-slot-port SLOT-[0..992]-[1..12]-[1..40]
LEDs on Ports (6500-T24) SLOT-shelf-slot-port SLOT-[0..992]-[1..24]-[1..40]
LEDs on Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..12]S[1..4]
T12)
LEDs on Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..24]S[1..4]
T24)
LEDs on Subslot SLOT-shelf-slotSsubslot-port SLOT-[0..992]-[1..12]S[1..4]-
Ports(6500-T12) [1..12,41..42]
LEDs on Subslot SLOT-shelf-slotSsubslot-port SLOT-[0..992]-[1..24]S[1..4]-
Ports(6500-T24) [1..12,41..42]
Input Parameter Description
Parameter Value Description Notes
state ON, OFF State To Set Lamp
AID Descriptions
AID Type Format Values
Equipment Slot (6500-T12) SLOT-shelf-slot SLOT-[0..992]-[1..12,41..42]
Equipment Slot (6500-T24) SLOT-shelf-slot SLOT-[0..992]-[1..24,41..42]
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
clean NO, YES Clean up existing log
collection. Required to
overwrite unsaved log
files.
collectcore NO, YES Request coredump
collection.
copyback NO, YES Copy logs from a
single slot back to
source slot.
exclude string Retrieve logs from all List must be in the
slots in the shelf form a-c,n,z
EXCEPT those
specified in this list.
include string Only retrieve logs from List must be in the
specified list of slots in form a-c,n,z
the shelf.
parallel NO, YES Attempt to collect from
multiple slots in
parallel.
prefix string Prefix a string to Allowable characters
RTRV-LOG file name A-Z,a-z,0-9,_,-
security NO, YES Retrieve security
related data from SP.
timeout INT Set timeout for log
(1-300 Default=20) collection from a single
slot. This parameter is
not supported when
collecting from multiple
slots. Default for Active
SP is 40 minutes,
default for all other
cards is 20 min.
AID Descriptions
AID Type Format Values
Equipment Slot (6500-T12) SLOT-shelf-slot SLOT-[0..992]-[1..12,41..42]
Equipment Slot (6500-T24) SLOT-shelf-slot SLOT-[0..992]-[1..24,41..42]
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
auto-log NO, YES Collect all autonomous Caution: the
logs generated by autonomous logs will
cards in shelf. be deleted if
KEEP=NO.
keep NO, YES Keep collected logs on
the NE after they've
been transferred.
url string Full URL to remote CLI will prompt for the
( min len=18 max len=300 ) directory inside quotes. user password with
The format of url is: echo disabled after the
[s]ftp://user:password command is entered.
@host[:port]/directory-
path. Maximum path
length is 128. The
password cannot
contain the character
'@'. If host is an IPv6
address, it must be
enclosed in square
brackets.
Environmental Alarms
alarms env show Retrieve Environment Alarm: this command retrieves the current environmental alarms
from the specified entity or entities.
alarms attr-env show The Retrieve Environment Alarm Attributes command retrieves the attributes associated
with environmental alarms. The response displays what each environmental alarm
register has been programmed to represent. In the response, an alarm type field
contains one of the 36 allowed types, followed by an alarm message preprogrammed by
the customer to describe the precise details.
alarms attr-env set Set Environmental Alarms Attributes: this command sets the attributes associated with
environmental alarms. These attributes are included when an environmental alarm is
reported or retrieved. If all attributes are null value, it unassigns the value. If some of
them are null, it keeps these null value attributes unchanged.
AID Descriptions
AID Type Format Values
Environmental alarm ENV-shelf-number ENV-[0..992]-[1..16]
contact number
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
alarm-type AIRCOMPR Air compressor failure
AIRCOND Air conditioning failure
AIRDRYR Air dryer failure
BATDSCHRG Battery discharging
BATTERY Battery failure
CLFAN Cooling fan failure
ENGINE Engine failure
ENGOPRG Engine operating
EXPLGS Explosive gas
FIRDETR Fire detector failure
FIRE Fire
FLOOD Flood
FUSE Fuse failure
GEN Generator failure
HIAIR High airflow
HIHUM High humidity
HITEMP High temperature
HIWTR High water
INTRUDER Intrusion
LWBATVG Low battery voltage
LWFUEL Low fuel
LWHUM Low humidity
LWPRES Low cable pressure
LWTEMP Low temperature
LWWTR Low water
MISC Miscellaneous
OPENDR Open door
PUMP Pump failure
POWER Commercial power
failure
PWR-48 48-V power supply
failure
RECT Rectifier failure
RECTHI Rectifier high voltage
RECTLO Rectifier low voltage
SMOKE Smoke
TOXICGAS Toxic gas
VENTN Ventilation system
failure
notification-code CR Critical
MJ Major
MN Minor
Syntax Definition
Parameter Attributes Description Notes
env-aid M AID
alarm-msg O This is the text string
(40 chars max)
associated with the
environmental input,
assigned by the user
with a SET-ATTR-ENV
command.
alarm-type M L The alarm type for the
environmental alarm.
notification-code M The notification code
for the environmental
alarm.
Equipment
equipment config create Enter Equipment: This command allows you to manually provision
equipment.
equipment config set Edit Equipment: This command allows you to edit the properties of
equipment.
equipment config delete Delete Equipment: This command allows you to disconnect a piece of
common equipment from a particular equipment slot.
equipment config disable Remove Equipment: This command allows you to remove one or more
equipment modules to out-of-service management state. The
equipment goes from in-service to an out-of-service management state.
equipment config enable Restore Equipment: This command allows you to restore one or more
equipment modules to in-service. The equipment goes from an out-of-
service management state to an in-service state.
equipment config show Retrieve Equipment: Retrieves the data parameters and state
parameters for provisioned equipment. If the equipment is not present
when this command is issued, it identifies only what is provisioned and
does not identify which equipment is actually present or missing. If the
equipment is present when the command is issued, it returns what is
provisioned and in addition returns information retrieved from the actual
equipment.
equipment equipment mode show Retrieve the equipment mode.
shelves shelf create Enter the Shelf Config attributes
shelves shelf delete De-provision the shelf
shelves shelf set Edit the Shelf Config Application.
shelves shelf show Retrieve the Shelf Config attributes.
equipment delay invoke Delay the response by given time (in seconds)
restart cold Initialize Cold: Instructs a Network Element to initialize a circuit
pack/pluggable depending if the request is for a slot/port respectively. A
cold initialization is equivalent to a power-up and will affect traffic.
restart warm Initialize Warm: instructs a Network Element to initialize its circuit packs.
A warm initialization does not affect traffic.
provisioning reset Reset provisioning to factory default
equipment auto-equip set Edit Auto-Equip mode: enable or disable the auto-equip mode for a slot.
equipment auto-equip show Retrieve Auto-Equip mode: display the auto-equip mode for a slot.
equipment inventory show Retrieve Inventory: This command identifies what type of circuit packs
reside in which slots.
equipment shelf nodeid set Set Shelf Node ID
equipment shelf nodeid show Rtrv Shelf Node ID
equipment usb delete Delete Usb Equipment: This command allows you to unmount USB
device.
equipment usb check Check Usb Equipment: This command allows you to check if there is
any usb devices on both usb ports.
equipment usb set Edit USB: Automount the USB device.
equipment usb show Retrieve USB Attributes like Automount and Mount status of the USB
ports.
equipment mount usb set Mount USB Equipment: This command allows to Mount the USB device
present on the usb port.
equipment unmount usb set Unmount USB Equipment: This command allows to unmount a mounted
filesystem present on the usb port
equipment equipment-attributes show Retrieves the specified attributes for provisioned equipment.
equipment inventory-attributes show Retrieves the specified attributes of circuit packs residing in a slot.
AID Descriptions
AID Type Format Values
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..12]
(6500-T12)
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..24]
(6500-T24)
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..12]
Colorless Mux/Demux
(6500-T12)
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..24]
Colorless Mux/Demux
(6500-T24)
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[3..4]
(6500-T12)
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[3..4]
(6500-T24)
AMP4 on MFC (6500-T12) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[1..4]
AMP4 on MFC (6500-T24) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[1..4]
Fiber Interconnect Module FIM-shelf-slot FIM-[0..992]-[71..78]
(6500-T12 / T24)
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..12]
(6500-T12)
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..24]
(6500-T24)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T24)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[1..4]
Colorless Mux/Demux on
MFC (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[1..4]
Colorless Mux/Demux on
MFC (6500-T24)
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[3..4]
(6500-T12)
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[3..4]
(6500-T24)
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[1..4]
T12)
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[1..4]
T24)
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..12]-[2]
Equipment on RLA (6500-
T12)
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..24]-[2]
Equipment on RLA (6500-
T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[1..40]
Factor Pluggable on
PKTOTN (6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[1..40]
Factor Pluggable on
PKTOTN (6500-T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[2]
Factor Pluggable on RLA
(6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[2]
Factor Pluggable on RLA
(6500-T24)
Multirate Small Form PSFP-shelf-slotSsubslot-port PSFP-[0..992]-slotSsubslot-[1..12]
Factor Pluggable on USSM
(6500-T12 / T24)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..12]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T12)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..24]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T24)
Multirate Quad (4-channel) PQSFP-shelf-slotSsubslot-port PQSFP-[0..992]-slotSsubslot-[1..5]
Small Form Factor
Pluggable on USSM (6500-
T12 / T24)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..12]-[1..5]
Pluggable on PKTOTN
(6500-T12)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..24]-[1..5]
Pluggable on PKTOTN
(6500-T24)
100G Base Form Factor PCFP2-shelf-slotSsubslot-port PCFP2-[0..992]-slotSsubslot-[1..2]
Pluggable on USSM (6500-
T12 / T24)
PKT/OTN I/F (6500-T12) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..12]
PKT/OTN I/F (6500-T24) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..24]
Switch Module (6500-T12) SM-shelf-slot SM-[0..992]-[31..34]
Switch Module (6500-T24) SM-shelf-slot SM-[0..992]-[31..39]
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..12]S[1..3]
AID (6500-T12)
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..24]S[1..3]
AID (6500-T24)
Input Parameter Description
Parameter Value Description Notes
prov-pec ident Provisioned PEC code
date1 date Operator defined
usage for Date1: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date2 date Operator defined
usage for Date2: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date3 date Operator defined
usage for Date3: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
label string Operator identifier for
equipment description.
64 Character
Maximum.
ntwksvc string Operator identifier for
facility name. 64
Character Maximum.
phase PLANNED Planned
UNVALIDATED Unvalidated
AVAILABLE Available
INUSE In Use
projid string Operator defined
usage for Project
IDentifier. 16
Character Maximum.
third-party NO Not a third party plug
YES A third party plug
usage UNKNOWN Unknown
NOTRSVD Not Reserved
RSVDMTC Reserved For
Maintenance
RSVDSVC Reserved For Facility
RSVDREV Reserved For
Reversion
pst IS In Service
OOS-MA Out of Service -
Management
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..12]-[2]
Equipment on RLA (6500-
T12)
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..24]-[2]
Equipment on RLA (6500-
T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[1..40]
Factor Pluggable on
PKTOTN (6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[1..40]
Factor Pluggable on
PKTOTN (6500-T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[2]
Factor Pluggable on RLA
(6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[2]
Factor Pluggable on RLA
(6500-T24)
Multirate Small Form PSFP-shelf-slotSsubslot-port PSFP-[0..992]-slotSsubslot-[1..12]
Factor Pluggable on USSM
(6500-T12 / T24)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..12]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T12)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..24]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T24)
Multirate Quad (4-channel) PQSFP-shelf-slotSsubslot-port PQSFP-[0..992]-slotSsubslot-[1..5]
Small Form Factor
Pluggable on USSM (6500-
T12 / T24)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..12]-[1..5]
Pluggable on PKTOTN
(6500-T12)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..24]-[1..5]
Pluggable on PKTOTN
(6500-T24)
100G Base Form Factor PCFP2-shelf-slotSsubslot-port PCFP2-[0..992]-slotSsubslot-[1..2]
Pluggable on USSM (6500-
T12 / T24)
CTM (6500-T12 / T24) CTM-shelf-slot CTM-[0..992]-[41..42]
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..12]
(6500-T12)
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..24]
(6500-T24)
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..12]
Colorless Mux/Demux
(6500-T12)
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..24]
Colorless Mux/Demux
(6500-T24)
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[3..4]
(6500-T12)
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[3..4]
(6500-T24)
AMP4 on MFC (6500-T12) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[1..4]
AMP4 on MFC (6500-T24) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[1..4]
Fiber Interconnect Module FIM-shelf-slot FIM-[0..992]-[71..78]
(6500-T12 / T24)
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..12]
(6500-T12)
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..24]
(6500-T24)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T24)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[1..4]
Colorless Mux/Demux on
MFC (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[1..4]
Colorless Mux/Demux on
MFC (6500-T24)
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[3..4]
(6500-T12)
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[3..4]
(6500-T24)
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[1..4]
T12)
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[1..4]
T24)
PKT/OTN I/F (6500-T12) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..12]
PKT/OTN I/F (6500-T24) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..24]
Input Parameter Description
Parameter Value Description Notes
prov-pec ident Provisioned PEC code
date1 date Operator defined
usage for Date1: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date2 date Operator defined
usage for Date2: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date3 date Operator defined
usage for Date3: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
label string Operator identifier for
equipment description.
64 Character
Maximum.
ntwksvc string Operator identifier for
facility name. 64
Character Maximum.
phase PLANNED Planned
UNVALIDATED Unvalidated
AVAILABLE Available
INUSE In Use
projid string Operator defined
usage for Project
IDentifier. 16
Character Maximum.
third-party NO Not a third party plug
YES A third party plug
usage UNKNOWN Unknown
NOTRSVD Not Reserved
RSVDMTC Reserved For
Maintenance
RSVDSVC Reserved For Facility
RSVDREV Reserved For
Reversion
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
ALL objects ALL ALL
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..12]
(6500-T12)
ROADM Line Amplifier RLA-shelf-slot RLA-[0..992]-[1..24]
(6500-T24)
All RLA slots RLA-shelf-ALL RLA-[0..992]-ALL
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..12]
Colorless Mux/Demux
(6500-T12)
16-Degree 12-Channel CCMD16X12-shelf-slot CCMD16X12-[0..992]-[1..24]
Colorless Mux/Demux
(6500-T24)
All CCMD16X12 slots CCMD16X12-shelf-ALL CCMD16X12-[0..992]-ALL
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[3..4]
(6500-T12)
AMP4 on CCMD16X12 AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[3..4]
(6500-T24)
All AMP4 slots AMP4-shelf-ALL AMP4-[0..992]-ALL
AMP4 on MFC (6500-T12) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..12]S[1..4]
AMP4 on MFC (6500-T24) AMP4-shelf-slotSsubslot AMP4-[0..992]-[1..24]S[1..4]
All AMP4 slots AMP4-shelf-ALL AMP4-[0..992]-ALL
Fiber Interconnect Module FIM-shelf-slot FIM-[0..992]-[71..78]
(6500-T12 / T24)
All FIM slots FIM-shelf-ALL FIM-[0..992]-ALL
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..12]
(6500-T12)
Multi-Functional Carrier MFC-shelf-slot MFC-[0..992]-[1..24]
(6500-T24)
All MFC slots MFC-shelf-ALL MFC-[0..992]-ALL
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[3..4]
Colorless Mux/Demux on
CCMD16X12 (6500-T24)
All CCMD8X4 slots CCMD8X4-shelf-ALL CCMD8X4-[0..992]-ALL
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..12]S[1..4]
Colorless Mux/Demux on
MFC (6500-T12)
8-Degree 4-Channel CCMD8X4-shelf-slotSsubslot CCMD8X4-[0..992]-[1..24]S[1..4]
Colorless Mux/Demux on
MFC (6500-T24)
All CCMD8X4 slots CCMD8X4-shelf-ALL CCMD8X4-[0..992]-ALL
CTM (6500-T12 / T24) CTM-shelf-slot CTM-[0..992]-[41..42]
All CTM slots CTM-shelf-ALL CTM-[0..992]-ALL
Switch Module (6500-T12) SM-shelf-slot SM-[0..992]-[31..34]
Switch Module (6500-T24) SM-shelf-slot SM-[0..992]-[31..39]
All SM slots SM-shelf-ALL SM-[0..992]-ALL
All P155M plugs (6500 T- P155M-shelf-ALL P155M-[0..992]-ALL
Series)
All PSFP plugs (6500 T- PSFP-shelf-ALL PSFP-[0..992]-ALL
Series)
All PQSFP plugs (6500 T- PQSFP-shelf-ALL PQSFP-[0..992]-ALL
Series)
All PCFP2 plugs (6500 T- PCFP2-shelf-ALL PCFP2-[0..992]-ALL
Series)
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..12]-[2]
Equipment on RLA (6500-
T12)
Pluggable 155Meg P155M-shelf-slot-ALL P155M-[0..992]-[1..12]-ALL
Equipment on RLA (6500-
T12)
Pluggable 155Meg P155M-shelf-slot-port P155M-[0..992]-[1..24]-[2]
Equipment on RLA (6500-
T24)
Pluggable 155Meg P155M-shelf-slot-ALL P155M-[0..992]-[1..24]-ALL
Equipment on RLA (6500-
T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[1..40]
Factor Pluggable on
PKTOTN (6500-T12)
Multirate Small Form PSFP-shelf-slot-ALL PSFP-[0..992]-[1..12]-ALL
Factor Pluggable on
PKTOTN (6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[1..40]
Factor Pluggable on
PKTOTN (6500-T24)
Multirate Small Form PSFP-shelf-slot-ALL PSFP-[0..992]-[1..24]-ALL
Factor Pluggable on
PKTOTN (6500-T24)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..12]-[2]
Factor Pluggable on RLA
(6500-T12)
Multirate Small Form PSFP-shelf-slot-ALL PSFP-[0..992]-[1..12]-ALL
Factor Pluggable on RLA
(6500-T12)
Multirate Small Form PSFP-shelf-slot-port PSFP-[0..992]-[1..24]-[2]
Factor Pluggable on RLA
(6500-T24)
Multirate Small Form PSFP-shelf-slot-ALL PSFP-[0..992]-[1..24]-ALL
Factor Pluggable on RLA
(6500-T24)
Multirate Small Form PSFP-shelf-slotSsubslot-port PSFP-[0..992]-slotSsubslot-[1..12]
Factor Pluggable on USSM
(6500-T12 / T24)
Multirate Small Form PSFP-shelf-slotSsubslot-ALL PSFP-[0..992]-slotSsubslot-ALL
Factor Pluggable on USSM
(6500-T12 / T24)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..12]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T12)
Multirate Quad (4-channel) PQSFP-shelf-slot-ALL PQSFP-[0..992]-[1..12]-ALL
Small Form Factor
Pluggable on PKTOTN
(6500-T12)
Multirate Quad (4-channel) PQSFP-shelf-slot-port PQSFP-[0..992]-[1..24]-[1..12]
Small Form Factor
Pluggable on PKTOTN
(6500-T24)
Multirate Quad (4-channel) PQSFP-shelf-slot-ALL PQSFP-[0..992]-[1..24]-ALL
Small Form Factor
Pluggable on PKTOTN
(6500-T24)
Multirate Quad (4-channel) PQSFP-shelf-slotSsubslot-port PQSFP-[0..992]-slotSsubslot-[1..5]
Small Form Factor
Pluggable on USSM (6500-
T12 / T24)
Multirate Quad (4-channel) PQSFP-shelf-slotSsubslot-ALL PQSFP-[0..992]-slotSsubslot-ALL
Small Form Factor
Pluggable on USSM (6500-
T12 / T24)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..12]-[1..5]
Pluggable on PKTOTN
(6500-T12)
100G Base Form Factor PCFP2-shelf-slot-ALL PCFP2-[0..992]-[1..12]-ALL
Pluggable on PKTOTN
(6500-T12)
100G Base Form Factor PCFP2-shelf-slot-port PCFP2-[0..992]-[1..24]-[1..5]
Pluggable on PKTOTN
(6500-T24)
100G Base Form Factor PCFP2-shelf-slot-ALL PCFP2-[0..992]-[1..24]-ALL
Pluggable on PKTOTN
(6500-T24)
100G Base Form Factor PCFP2-shelf-slotSsubslot-port PCFP2-[0..992]-slotSsubslot-[1..2]
Pluggable on USSM (6500-
T12 / T24)
100G Base Form Factor PCFP2-shelf-slotSsubslot-ALL PCFP2-[0..992]-slotSsubslot-ALL
Pluggable on USSM (6500-
T12 / T24)
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
PKT/OTN I/F (6500-T12) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..12]
PKT/OTN I/F (6500-T24) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..24]
All PKTOTN slots PKTOTN-shelf-ALL PKTOTN-[0..992]-ALL
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[3..4]
(6500-T12)
OTDR4 on CCMD16X12 OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[3..4]
(6500-T24)
All OTDR4 slots OTDR4-shelf-ALL OTDR4-[0..992]-ALL
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..12]S[1..4]
T12)
OTDR4 on MFC (6500- OTDR4-shelf-slotSsubslot OTDR4-[0..992]-[1..24]S[1..4]
T24)
All OTDR4 slots OTDR4-shelf-ALL OTDR4-[0..992]-ALL
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..12]S[1..3]
AID (6500-T12)
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..24]S[1..3]
AID (6500-T24)
Input Parameter Description
Parameter Value Description Notes
flt-rec-info NO Do not include Flight
Recorder information
in the response
YES Include Flight Default= YES
Recorder information
in the response
Syntax Definition
Parameter Attributes Description Notes
eqpt M AID
age O Age, cumulative in- It will be returned only
service time elapsed if the equipment is
since manufacture, in present.
the format: years-days-
hours-minutes (YY-
DDD-HH-MM).
ains-time-left O The format will be "HH-
MM" for the time left in
AINS timeout.
clei O CLEI CLEI 10 alphanumeric
characters, it will be
returned only if the
equipment is present.
ctm-extender O The CTM Extender If no CTM Extender is
AID that the CTM is interworking with a
interworking with in a given CTM AID, NONE
6500-T24 shelf is the value returned.
ctype M Card Type
date1 O R Operator defined
usage for Date1: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date2 O R Operator defined
usage for Date2: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date3 O R Operator defined
usage for Date3: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
eqpt-grp O Equipment Group AID
eqpt-profile O Equipment Profile
height O Card Slot Height
label O R Operator identifier for
equipment description.
64 Character
Maximum.
mdat O Date of Manufacture, It will be returned only
in the format: year- if the equipment is
week of year (YYYY- present.
WW).
on-since O On since, cumulative It will be returned only
time since the unit was if the equipment is
last inserted, in the present.
format: years-days-
hours-minutes (YY-
DDD-HH-MM).
pec O Actual PEC Code Actual PEC Code 8
alphanumeric
characters, it will be
returned only if the
equipment is present.
phase O Circuit Packet
Availability Field
projid O R Operator defined
usage for Project
IDentifier. 16
Character Maximum.
prov-pec M Provisioned PEC Code 8 alphanumeric
characters
rate-class O Pluggable rate class
rel O Release Level Release Level, it will
be returned only if the
equipment is present.
ser O Serial Number Serial Number 25
alphanumeric
characters, it will be
returned only if the
equipment is present.
snmp-index O Identifies the index of range of values from 0
the equivalent entity to 2^32-1
instance in the SNMP
entityPhysical MIB
group
third-party O If a third party
pluggable is being
provisioned
usage O Circuit Packet Usage
Field
width O Card Slot Width
pst M Identify the primary
state
sst M L Identify the secondary
state
Output Parameter Description
Parameter Value Description Notes
eqpt ident AID
age ident Age, cumulative in- It will be returned only
service time elapsed if the equipment is
since manufacture, in present.
the format: years-days-
hours-minutes (YY-
DDD-HH-MM).
ains-time-left time The format will be "HH-
MM" for the time left in
AINS timeout.
clei ident CLEI CLEI 10 alphanumeric
characters, it will be
returned only if the
equipment is present.
ctm-extender ident The CTM Extender If no CTM Extender is
AID that the CTM is interworking with a
interworking with in a given CTM AID, NONE
6500-T24 shelf is the value returned.
ctype string Card Type
date1 date Operator defined
usage for Date1: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date2 date Operator defined
usage for Date2: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
date3 date Operator defined
usage for Date3: yy =
00..99, mm = 00..12,
dd = 00..31. 00-00-00
is the default/unused
value.
eqpt-grp ident Equipment Group AID
eqpt-profile FIXEDGRID Photonics Equipment -
Supports Fixed Grid
height ident Card Slot Height
label string Operator identifier for
equipment description.
64 Character
Maximum.
mdat ident Date of Manufacture, It will be returned only
in the format: year- if the equipment is
week of year (YYYY- present.
WW).
on-since ident On since, cumulative It will be returned only
time since the unit was if the equipment is
last inserted, in the present.
format: years-days-
hours-minutes (YY-
DDD-HH-MM).
pec ident Actual PEC Code Actual PEC Code 8
alphanumeric
characters, it will be
returned only if the
equipment is present.
phase PLANNED Planned
UNVALIDATED Unvalidated
AVAILABLE Available
INUSE In Use
projid string Operator defined
usage for Project
IDentifier. 16
Character Maximum.
prov-pec ident Provisioned PEC Code 8 alphanumeric
characters
rate-class NONE No rate class
A Rate class A
B Rate class B
C Rate class C
D Rate class D
rel string Release Level Release Level, it will
be returned only if the
equipment is present.
ser ident Serial Number Serial Number 25
alphanumeric
characters, it will be
returned only if the
equipment is present.
snmp-index INT Identifies the index of range of values from 0
(0-4294967295) the equivalent entity to 2^32-1
instance in the SNMP
entityPhysical MIB
group
third-party NO Not a third party plug
YES A third party plug
usage UNKNOWN Unknown
NOTRSVD Not Reserved
RSVDMTC Reserved For
Maintenance
RSVDSVC Reserved For Facility
RSVDREV Reserved For
Reversion
width ident Card Slot Width
pst IS In Service
IS-ANR In Service - Abnormal
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
OOS-AU Out-of-service
autonomous from a
failure detected point
of view. It is not out of
service from a state
point of view. Alarm is
raised if the entity is
not able to perform its
provisioned functions
OOS-AUMA Out-of-service
autonomous
management - the
entity is not able to
perform its provisioned
functions and is
purposefully removed
from service
OOS-MAANR Out-of-service
maintenance -
abnormal.
sst ACT Active, carrying traffic
AINS Auto-In-Service
FLT Fault detected in
equipment
IDLE Idle, not carrying traffic
MEA Mismatched
equipment attributes
PWROFF Power Off
SGEO Supporting entity
outage
STBY Standby
STBYH Hot standby
TS Test
UEQ Unequipped, circuit
pack missing
WRK Working
WRKCTRL Working Control Plane
WRKOAM Working Operations,
Administration, and
Maintenance
WRKSYNC Working clock
WRKTRAF Working traffic
XALGN CTM Extender
Aligned: In 6500-T24,
CTM in slot 41 is
aligned with non-faulty
CTM Extender in slot
43, or CTM in slot 42 is
aligned with non-faulty
CTM Extender in slot
44
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
act-fltr-timer ENABLE Activate Timer
DISABLE Do not activate timer
bay-num INT Bay Number Range 0..99. This
(0-99 Default=0) parameter defines the
bay ID where the shelf
is located. It is
optionally reported in
AO messages.
clustering ENABLE REST/GRPC/CLI
interfaces enabled for
TID Consolidation
DISABLE REST/GRPC/CLI
interfaces disabled for
TID Consolidation
fic string FIC Frame Identification
Code. This is
optionally reported in
AO messages.
fltr-timer INT Filter Timer Value in
(0-1826) days (0-1826)
location string Location Latitude and Longitude
of shelf
phys-shelf INT Physical Shelf Number Range 0..9. This
(0-9 Default=0) parameter defines the
physical shelf number
within a bay. It is
optionally reported in
AO messages.
primary ENABLE Activate Shelf as
Primary
DISABLE Do not Activate
site-group INT Unordered list of Grouping using & is
(1-65535) maximum 20 SITEID supported. To
values from 1-65535. provision, user must
specify the
corresponding shelf
SITEID in the list. To
reset, pass empty
value.
site-id INT Site ID. Range 0..65535 (0
(0-65535 Default=0) indicates not defined)
site-name string Site Name. Maximum length of 20
characters
subnet-name string Subnet Name Subnet name, range
up to 36 alphanumeric
characters.
tidc ENABLE TID Consolidation
feature is enabled.
DISABLE TID Consolidation
feature is disabled.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
act-fltr-timer ENABLE Activate Timer
DISABLE Do not activate timer
bay-num INT Bay Number Range 0..99. This
(0-99 Default=0) parameter defines the
bay ID where the shelf
is located. It is
optionally reported in
AO messages.
clustering ENABLE REST/GRPC/CLI
interfaces enabled for
TID Consolidation
DISABLE REST/GRPC/CLI
interfaces disabled for
TID Consolidation
fic string FIC Frame Identification
Code. This is
optionally reported in
AO messages.
fltr-timer INT Filter Timer Value in
(0-1826) days (0-1826)
location string Location Latitude and Longitude
of shelf
new-shelf-id SHELF SHELF- SHELF- SHELF-shelf
shelf [0..992]
phys-shelf INT Physical Shelf Number Range 0..9. This
(0-9 Default=0) parameter defines the
physical shelf number
within a bay. It is
optionally reported in
AO messages.
primary ENABLE Activate Shelf as
Primary
DISABLE Do not Activate
site-group INT Unordered list of Grouping using & is
(1-65535) maximum 20 SITEID supported. To
values from 1-65535. provision, user must
specify the
corresponding shelf
SITEID in the list.To
reset, pass empty
value.
site-id INT Site ID.
(0-65535)
site-name string Site Name.
subnet-name string Subnet Name Subnet name, range
up to 36 alphanumeric
characters.
tidc ENABLE TID Consolidation
feature is enabled
DISABLE TID Consolidation
feature is disabled.
AID Descriptions
AID Type Format Values
Equipment Slot (6500-T12) SLOT-shelf-slot SLOT-[0..992]-[1..12,41..42]
Equipment Slot (6500-T24) SLOT-shelf-slot SLOT-[0..992]-[1..24,41..42]
Equipment Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..12]S[1..4]
T12)
Equipment Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..24]S[1..4]
T24)
Input Parameter Description
Parameter Value Description Notes
cpux string Processor (denoted by CPU1:OAM
a 4 character identifier, Processor,
of the form CPUx or CPU2:AUXP
cpux) to warm restart if Processor
there is more than one
processor on a card.
Ex: CPU1 for OAM
Processor, CPU2 for
Auxiliary
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
mode DEFAULT Factory default
MODE1 Factory default and
preserve comms data
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
node-id INT Shelf Node ID.
AID Descriptions
AID Type Format Values
All USBs on shelf USB-shelf-ALL USB-[0..992]-ALL
USB AID USB-shelf-slot-port USB-[0..992]-[41..42]-[1..2]
USB AID USB-shelf-slot-ALL USB-[0..992]-[41..42]-ALL
USB AID USB-shelf-slot-port USB-[0..992]--[1..2]
USB AID USB-shelf-slot-ALL USB-[0..992]--ALL
Input Parameter Description
Parameter Value Description Notes
on-off ON Automount ON
OFF Automount OFF
AID Descriptions
AID Type Format Values
PKT/OTN I/F (6500-T12) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..12]
PKT/OTN I/F (6500-T24) PKTOTN-shelf-slot PKTOTN-[0..992]-[1..24]
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..12]S[1..3]
AID (6500-T12)
Universal Subslot Module USSM-shelf-slotSsubslot USSM-[0..992]-[1..24]S[1..3]
AID (6500-T24)
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
attribute-type TRANSMODE TRANSMODE attribute
type.
MODEMCLASS MODEMCLASS
attribute type.
CCT CCT attribute type.
RESNR Supported value of
reference ESNRs per
transmission mode.
TXPOWER Supported range of Tx
Power.
SPECTRALINFO Supported value of the
3dB, 10dB and
Minimum spectral
bandwidth per
transmission mode.
CARRIERRANGE Supported carrier
range of the laser
frequency and
wavelength.
Syntax Definition
Parameter Attributes Description Notes
eqpt-aid M aid
dfltlinkoptmode O Default Link
Optimization Mode for
the related
Transmode.
linkoptmode O Supported Link
Optimization Mode for
the related
Transmode.
transmode M Transmode supported
AID Descriptions
AID Type Format Values
Equipment Slot (6500-T12) SLOT-shelf-slot SLOT-[0..992]-
[1..12,31..34,40..42,51..53,61..62]
Equipment Slot (6500-T24) SLOT-shelf-slot SLOT-[0..992]-
[1..24,31..39,40..44,51..55,61..64]
Equipment Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..12]S[1..4]
T12)
Equipment Subslot (6500- SLOT-shelf-slotSsubslot SLOT-[0..992]-[1..24]S[1..4]
T24)
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
attribute-type TRANSMODE TRANSMODE attribute
type.
MODEMCLASS MODEMCLASS
attribute type.
CCT CCT attribute type.
RESNR Supported value of
reference ESNRs per
transmission mode.
TXPOWER Supported range of Tx
Power.
SPECTRALINFO Supported value of the
3dB, 10dB and
Minimum spectral
bandwidth per
transmission mode.
CARRIERRANGE Supported carrier
range of the laser
frequency and
wavelength.
supported-level MODEM Modem Supported
Level type.
CARD Card Supported Level
type.
Syntax Definition
Parameter Attributes Description Notes
slot-aid M aid
dfltlinkoptmode O Default Link
Optimization Mode for
the related
Transmode.
linkoptmode O Supported Link
Optimization Mode for
the related
Transmode.
transmode M Transmode supported
attr-10dbwth O Supported value of
10dB bandwidth in
GHz
attr-3dbwth O Supported value of
3dB bandwidth in GHz.
attr-freqmax O Supported value of the
maximum laser
frequency in THz
(xxx.xxxx)
attr-freqmin O Supported value of the
minimum laser
frequency in THz
(xxx.xxxx)
attr-minspectwth O Supported value of the
minimum spectral
bandwidth in GHz
attr-resnr O Supported value of the
Reference Signal
Noise Ratio in dBm
(xx.x).
attr-txpwrmax O Supported value of the
maximum Tx Power in
dBm (xx.x)
attr-txpwrmin O Supported value of the
minimum Tx Power in
dBm (xx.x).
modem-class O Modem Class
External Controls
alarms ext-cont operate Operate External Controls: this command allows a surveillance operations system to
instruct the target network element to operate the parallel relay outputs on the
network element.
alarms ext-cont release Release External Controls: this command allows a surveillance operations system to
instruct the target network element to release the parallel relay outputs on the network
element.
alarms attr-cont show The Retrieve External Control Attributes command retrieves the attributes associated
with external controls. The attributes are the text strings assigned by the
corresponding SET command, which identify the function of the control relay.
alarms ext-cont show Retrieve External Controls: this command allows a surveillance operations system to
instruct the target network element to view the parallel relay outputs on the network
element.
alarms attr-cont set Set Attributes Control: this command sets the attributes associated with external
controls. The attributes are used to indicate what the external control is used for.
AID Descriptions
AID Type Format Values
ALL objects ALL ALL
External Control Contact CONT-shelf-number CONT-[0..992]-[1..4]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
cont-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
AID Descriptions
AID Type Format Values
ALL objects ALL ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
External Control Contact CONT-shelf-number CONT-[0..992]-[1..4]
Input Parameter Description
Parameter Value Description Notes
cont-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
AID Descriptions
AID Type Format Values
External Control Contact CONT-shelf-number CONT-[0..992]-[1..4]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
control-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
Syntax Definition
Parameter Attributes Description Notes
cont M aid
control-type O L The type of control for
which the control state
is being set.
Output Parameter Description
Parameter Value Description Notes
cont ident aid
control-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
AID Descriptions
AID Type Format Values
External Control Contact CONT-shelf-number CONT-[0..992]-[1..4]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
cont-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
Syntax Definition
Parameter Attributes Description Notes
cont M aid
conts M Duration is continuous,
momentary is not
supported.
contstate M Control state.
cont-type O The type of control for
which the control state
is being set.
AID Descriptions
AID Type Format Values
External Control Contact CONT-shelf-number CONT-[0..992]-[1..4]
Input Parameter Description
Parameter Value Description Notes
control-type AIRCOND Air Conditioning
ENGINE Engine
FAN Fan
GEN Generator
HEAT Heat
LIGHT Light
MISC Miscellaneous
SPKLR Sprinkler
Facility
adjacencies spli create Add a shelf entry to the SPLI shelf DB. An entry in this DB contains the
far-end shelf info for SPLI to communicate with it.
adjacencies spli set Performs an edit of a SPLI shelf database entry.
photonic controller disable Remove the DOC Facility from service.
photonic controller enable Restore the DOC Facility from service.
photonic controller set Edit the DOC Facility.
photonic controller show Retrieve the DOC Facility attributes.
photonic channel set Allows the user to specify channel actions, Add, Delete or Stop.
photonic channel show Retrieve DOC Channels attributes.
photonic logs show Retrieve the DOC logs.
photonic class set Edit the DOC MODULATION CLASS.
photonic class show Retrieve the DOC MODULATION CLASS.
amps amp create Create the AMP Facility.
amps amp delete Delete the AMP Optical Facility.
amps amp disable Removes the AMP Optical Facility from service.
amps amp enable Restores the AMP Optical Facility to service.
amps amp set Edits the AMP Facility.
amps amp show Retrieve the AMP Facility attributes.
channel-control chc disable Puts the given channel control facility of a WSS card OOS
channel-control chc enable Puts the given channel control facility of a WSS card IS
channel-control chc create Create a channel control facility
channel-control chc delete Delete the given channel control facility of a WSS card
channel-control chc set Edits attributes of a given channel control facility
channel-control chc show Retrieves attributes of a given channel control facility
port wan set Edit WAN Facility.
port wan show Retrieve WAN Facility attributes.
oscs osc disable Remove the OSC Facility from service.
oscs osc enable Restore the OSC Facility to service.
oscs osc show Retrieve the OSC Facility attributes.
oscs osc set Edit the OSC Facility attributes.
oscs osc create Create the OSC Facility
oscs osc delete Delete the OSC Facility.
optmons optmon create Create the Optical Monitoring Facility.
optmons optmon delete Delete the Optical Monitoring Facility.
optmons optmon disable Removes the Facility from Service.
optmons optmon enable Restores the Facility back to Service.
optmons optmon set Edit the Optical Monitoring Facility.
optmons optmon show Retrieves the Attributes of the Optical Monitoring Facility.
voas voa create Creates the VOA Optical Facility.
voas voa delete Delete the VOA Optical Facility.
voas voa disable Removes the VOA Optical Facility from service.
voas voa enable Restores the VOA Optical Facility to service.
voas voa set Edits the VOA Optical Facility.
voas voa show Retrieve the VOA Optical Facility attributes.
port ptp create Create a PTP Facility.
port ptp set Edit PTP Facility
port ptp show Retrieve the PTP facility parameters
port ptp delete Delete a PTP Facility
port ptp disable Switch PTP Facility Out of Service
port ptp enable Switch PTP Facility In Service
port dispscan ptp init Dispersion scanning against PTP facility
port otuttp create Create an OTU Facility.
port otuttp delete Delete an OTUTTP Facility
port otuttp set Edit parameters of an OTU Facility
port otuttp show Retrieve the OTUTTP facility parameters
port otuttp disable Switch OTUTTP Facility Out of Service
port otuttp enable Delete OTU facility (System command)
port loopback otuttp operate Operate loopback on specified facility.
port loopback otuttp release Release loopback on specified facility.
port loopback otuttp show Retrieve loopback settings.
port sttp create Create an STTP Facility.
port sttp delete Delete an STTP Facility
port sttp set Edit an STTP Facility
port sttp show Retrieve the STTP facility parameters
port sttp disable Switch STTP Facility Out of Service
port sttp enable Switch STTP Facility In Service
port loopback sttp operate Operate loopback on specified facility.
port loopback sttp release Release loopback on specified facility.
port loopback sttp show Retrieve loopback settings.
port ettp create Create an ETTP Facility.
port ettp delete Delete an ETTP Facility
port ettp set Edit an ETTP Facility
port ettp show Retrieve the ETTP facility parameters
port ettp disable Switch ETTP Facility Out of Service
port ettp enable Switch ETTP Facility In Service
port loopback ettp operate Operate loopback on specified facility.
port loopback ettp release Release loopback on specified facility.
port loopback ettp show Retrieve loopback settings.
port oduttp create Create an ODUTTP Facility.
port oduttp set Edit an ODUTTP Facility
port oduttp show Retrieve the ODUTTP facility parameters
port oduttp delete Delete an ODUTTP Facility
port oduttp disable Switch ODUTTP Facility Out of Service
port oduttp enable Switch ODUTTP Facility In Service
port oductp create Create an ODUCTP Facility.
port oductp set Edit an ODUCTP Facility
port oductp show Retrieve the ODUCTP facility parameters
port oductp delete Delete an ODUCTP Facility
port oductp disable Switch ODUCTP Facility Out of Service
port oductp enable Switch ODUTTP Facility In Service
port tcm create Create a TCM Facility.
port tcm set Edit TCM Facility
port tcm show Retrieve the TCM facility parameters
port tcm delete Delete a TCM Facility
port tcm disable Switch TCM Facility Out of Service
port tcm enable Switch TCM Facility In Service
line-diag telemetry disable Remove a TELEMETRY facility from service
line-diag telemetry enable Restore a TELEMETRY facility to service
line-diag telemetry set Edit a TELEMETRY facility
line-diag telemetry show Retrieve the TELEMETRY facility attributes
equipment group config set Edit an Equipment Group
equipment group config show Retrieve Equipment Group
port pc set Edits the PC Facility.
port pc show Retrieve the PC Facility attributes.
channel-control ssc set Edits the SSC Facility.
channel-control ssc show Retrieve the SSC Facility attributes.
channel-control nmcc set Edit an NMCC facility
channel-control nmcc show Retrieve the NMCC facility attributes
channel-control nmcc create Create an NMCC facility
channel-control nmcc delete Delete an NMCC facility
channel-control nmcc init-power-profile Reset the power profile of the specified NMCC facilities
line-diag config set Edit OTDRCFG facility
line-diag config show Retrieve the OTDRCFG facility attributes
line-diag otdr trace start Operate OTDR Measurement: Instructs a network element to start the
OTDR Measurement
line-diag otdr trace stop Stop the ongoing OTDR Measurement
line-diag otdr trace set-baseline Instructs a network element to tag the current SOR file specified with
the TRACE TYPE as BASELINE
line-diag otdr trace show Retrieve the SOR (Standard OTDR Record) file specified by the
TRACETYPE and TRACETAG parameters, and transfer it to the
external server located at the specified URL or output it as a byte
stream in TL1
line-diag otdr traces show List all SOR (Standard OTDR Record) files that have been completed
so far.
line-diag events show List all the events corresponding to the given OTDR Trace
adjacencies txrx-profile set Edit a transponder profile
adjacencies txrx-profile show Retrieve the transponder profile attributes
Top of Facility Section
adjacencies spli create
Description: Add a shelf entry to the SPLI shelf DB. An entry in this DB contains the far-end shelf info
for SPLI to communicate with it.
CLI command: adjacencies spli create
Security Level: 3
Input syntax adjacencies spli create <aid> [commstype <Value>]fend-ip-addr <Value>
[keyformat <Value>][platform-type <Value>]spli-id <Value>
Syntax Definition
Parameter Attributes Description Notes
commstype O Transport protocol for n/a
establishing the
connection with the
far-end NE.
fend-ip-addr M IPv4 address of the n/a
far-end NE.
keyformat O The format for the n/a
SPLI_ID.
platform-type O Platform Type of the n/a
far-end NE.
spli-id M Key ID of the table n/a
entry. KEYFORMAT
parameter defines its
format.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
commstype UDP, TCPSSH Transport protocol for n/a
establishing the
connection with the
far-end NE.
fend-ip-addr string IPv4 address of the n/a
far-end NE.
keyformat TID-SHELF, TID-BAY, The format for the n/a
NODENAME SPLI_ID.
platform-type 6500, 5400, 8700, WAVESERVER Platform Type of the n/a
far-end NE.
spli-id string Key ID of the table n/a
entry. KEYFORMAT
parameter defines its
format.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
commstype UDP, TCPSSH Transport protocol for n/a
establishing the
connection with the
far-end NE.
fend-ip-addr string IPv4 address of the n/a
far-end NE.
index INT Index associated with n/a
the far-end shelf entry.
platform-type 6500, 5400, 8700, WAVESERVER Platform Type of the n/a
far-end NE.
AID Descriptions
AID Type Format Values
DOC DOC-shelf-instance DOC-[0..992]-[1..8]
Input Parameter Description
Parameter Value Description Notes
action STOP Stop channel adds and
deletes.
CLRALM Clear DOC alarm.
RESETTCA Resets all Threshold
Crossing Alert (TCA)
Baselines for the entire
domain.
REOPT re-optimize.
CLRLOG Clear DOC log.
POWERAUDIT Perform power audit.
auto-add ENABLE Enable Auto-Add
DISABLE Disable Auto-Add
auto-del ENABLE Enable Auto-Del
DISABLE Disable Auto-Del
auto-del-los ENABLE
DISABLE
auto-del-los-holdoff INT Represents the
(1-120) minimum time in
minute required before
executing auto-squelch
feature.
docfusethresh INT Represents the Re-Opt
(1-60) threshold before the
DOC Fuse is activated.
Valid range for this
parameter is between
1 - 60. 1-59 represents
the number of Re-Opt
iterations runs after
which the DOC Fuse
will be blown. 60
represents the DOC
Fuse feature is
disabled.
doc-mode AUTOMON Only performs auto
monitoring.
ENHANCED Enhanced mode.
gain-clamp ENABLE
DISABLE
AID Descriptions
AID Type Format Values
NC NC-shelf-siteid-remshelf- NC-[0..992]-[0..65535]-[0..992]-
rempath-wavelength [1..254]-[0..999999]
AID Descriptions
AID Type Format Values
NC NC-shelf-siteid-remshelf- NC-[0..992]-[0..65535]-[0..992]-
rempath-wavelength [1..254]-[0..999999]
DOC DOC-shelf-instance DOC-[0..992]-[1..8]
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
ch-type ADDABLE Get the channels
which are addable.
DELETABLE Get the channels
which are deletable.
Syntax Definition
Parameter Attributes Description Notes
aid M aid n/a
channel-fault-status M The Channel Fault A quoted string of
Status. characters.
channel-opt-status M The Channel A quoted string of
Condition. characters.
ch-type O The type of channels
to be retrieve from
DOC.
cktid M Circuit ID Previously called CLCI
docinst M DOC AID DOC AID for the
channel. Format:
DOC-shelf-instance
doc-trail O Domain Trail for the The string will be of
Network Channel the format "TID:DOC-
shelf-instance" triplets.
doc-trail-status O Domain Trail for the
Network Channel
Status. If COMPLETE,
the full domain trail is
available. If
INCOMPLETE, a
partial domain trail is
available.
domain-routing M Channel Routing in A quoted string of
Domain characters.
egress M The Egress TID-Shelf- Formatted string tid-#-
Path #
end-to-end-condition O The Channel End to A quoted string of
End Condition. characters.
est-incr-osnr M Estimated Incremental A quoted string of up
OSNR to 6 characters.
ingress M The Ingress TID-Shelf- Formatted string tid-#-
Path #
ingress-active-flag M The Channel Ingress A quoted string of
Active Flag. characters.
mod-class M Modulation Class.
ne-trail O The NE Trail for the Formatted string tid-#-
channel #,tid-#-#...
snr-bias M SNR Bias The snrbias in format
xx.xx, and dB will be
assumed.
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
CHC-[0..992]-[1..99]-
[5,8,9..10,12,18,20,22]-ALL
CHC-[0..992]-[1..99]-ALL
CHC AIDs CHC-[0..992]-[1..99]-[1..4]S[3..10]-
CHC-shelf-slot-portSsubport-
index [1..128,100000..999999]
CHC-[0..992]-[1..99]-[1..4]S[3..10]-ALL
CHC-[0..992]-[1..99]-[1..4]-ALL
CHC-[0..992]-[1..99]-ALL
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..12]-[5,8]-[1..128]
T12) CHC-[0..992]-[1..12]-[5,8]-ALL
CHC-[0..992]-[1..12]-ALL
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..24]-[5,8]-[1..128]
T24) CHC-[0..992]-[1..24]-[5,8]-ALL
CHC-[0..992]-[1..24]-ALL
RLA ALL CHC (6500-T12) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..12]-[5,8]-ALL
RLA ALL CHC (6500-T12) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..24]-[5,8]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
T12)
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..24]-ALL
T24)
CHCs All Slots CHC-shelf-ALL CHC-[0..992]-ALL
CHC-[0..992]-[1..99]-
[5,8,9..10,12,18,20,22]-ALL
CHC-[0..992]-[1..99]-ALL
CHC AIDs CHC-shelf-slot-portSsubport- CHC-[0..992]-[1..99]-[1..4]S[3..10]-
index [1..128,100000..999999]
CHC-[0..992]-[1..99]-[1..4]S[3..10]-ALL
CHC-[0..992]-[1..99]-[1..4]-ALL
CHC-[0..992]-[1..99]-ALL
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..12]-[5,8]-[1..128]
T12) CHC-[0..992]-[1..12]-[5,8]-ALL
CHC-[0..992]-[1..12]-ALL
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..24]-[5,8]-[1..128]
T24) CHC-[0..992]-[1..24]-[5,8]-ALL
CHC-[0..992]-[1..24]-ALL
RLA ALL CHC (6500-T12) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..12]-[5,8]-ALL
RLA ALL CHC (6500-T12) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..24]-[5,8]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
T12)
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..24]-ALL
T24)
CHCs All Slots CHC-shelf-ALL CHC-[0..992]-ALL
AID Descriptions
AID Type Format Values
CHC AIDs CHC-shelf-slot-port-index CHC-[0..992]-[1..99]-
[5,8,9..10,12,18,20,22]-
[1..128,100000..999999]
CHC AIDs CHC-shelf-slot-portSsubport- CHC-[0..992]-[1..99]-[1..4]S[3..10]-
index [1..128,100000..999999]
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..12]-[5,8]-[1..128]
T12)
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..24]-[5,8]-[1..128]
T24)
Input Parameter Description
Parameter Value Description Notes
max-freq string Maximum Channel Range = 191.36250
Frequency THz to 196.12500 THz
min-freq string Minimum Channel Range = 191.32500
Frequency THz to 196.08750 THz
opaque YES
NO
sw-sel 21S2 21S2
21S3 21S3
21S4 21S4
21S5 21S5
21S6 21S6
21S7 21S7
21S8 21S8
21S9 21S9
21S10 21S10
21S11 21S11
22S2 22S2
22S3 22S3
22S4 22S4
22S5 22S5
22S6 22S6
22S7 22S7
22S8 22S8
22S9 22S9
22S10 22S10
22S11 22S11
23S2 23S2
23S3 23S3
23S4 23S4
23S5 23S5
23S6 23S6
23S7 23S7
23S8 23S8
23S9 23S9
23S10 23S10
23S11 23S11
24S2 24S2
24S3 24S3
24S4 24S4
24S5 24S5
24S6 24S6
24S7 24S7
24S8 24S8
24S9 24S9
24S10 24S10
24S11 24S11
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
AID Descriptions
AID Type Format Values
CHC AIDs CHC-shelf-slot-port-index CHC-[0..992]-[1..99]-
[5,8,9..10,12,18,20,22]-
[1..128,100000..999999]
CHC AIDs CHC-shelf-slot-portSsubport- CHC-[0..992]-[1..99]-[1..4]S[3..10]-
index [1..128,100000..999999]
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..12]-[5,8]-[1..128]
T12)
RLA CHC Index (6500- CHC-shelf-slot-port-index CHC-[0..992]-[1..24]-[5,8]-[1..128]
T24)
RLA ALL CHC (6500-T12) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..12]-[5,8]-ALL
RLA ALL CHC (6500-T12) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-port-ALL CHC-[0..992]-[1..24]-[5,8]-ALL
RLA ALL CHC (6500-T24) CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..12]-ALL
T12)
ALL CHCs on a slot (6500- CHC-shelf-slot-ALL CHC-[0..992]-[1..24]-ALL
T24)
CHCs All Slots CHC-shelf-ALL CHC-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
chc-mode LOSS Target Loss Control
Mode
POWER Target Power Control
Mode
OPENLOOPLOSS Target Loss Control
Open Loop Mode
opaque YES
NO
sw-sel 21S2 21S2
21S3 21S3
21S4 21S4
21S5 21S5
21S6 21S6
21S7 21S7
21S8 21S8
21S9 21S9
21S10 21S10
21S11 21S11
22S2 22S2
22S3 22S3
22S4 22S4
22S5 22S5
22S6 22S6
22S7 22S7
22S8 22S8
22S9 22S9
22S10 22S10
22S11 22S11
23S2 23S2
23S3 23S3
23S4 23S4
23S5 23S5
23S6 23S6
23S7 23S7
23S8 23S8
23S9 23S9
23S10 23S10
23S11 23S11
24S2 24S2
24S3 24S3
24S4 24S4
24S5 24S5
24S6 24S6
24S7 24S7
24S8 24S8
24S9 24S9
24S10 24S10
24S11 24S11
AID Descriptions
AID Type Format Values
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
AID Descriptions
AID Type Format Values
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]
rt1Ptp1
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
stats-info NO Do not include
Dynamic Status
information in the
response
YES Include Dynamic
Status information in
the response
Syntax Definition
Parameter Attributes Description Notes
wan M aid
actual-rx-units M Current number of
active members in the
receive direction.
When LCAS is
disabled, allowable
values are either 0 or
PROVRXUNITS. With
LCAS enabled,
allowable values are 0
to PROVRXUNITS. If
the value cannot be
retrieved, UNKNOWN
will be displayed.
actual-units M Indicates the number
of bandwidth units
actually carrying traffic.
For contiguous
concatenation, or for
virtual concatenation
without LCAS enabled,
allowable values are
either 0 or
PROVUNITS. With
LCAS enabled,
allowable values are 0
to PROVUNITS. If the
value cannot be
retrieved, UNKNOWN
will be displayed.
available-rate M L Used to indicate the
available bandwidth
rate in the wan port.
bw-remain O The unused bandwidth
remained for a given
port (in KBIT)
bw-threshld O The bandwidth
utilization percentage
threshold
bw-utl O The port bandwidth
utilization percentage
cf-prf O The AID of the port
Control Frame Profile
(CFPRF-shelf-
profileNo)
cond-type O This attribute is used In FC mode, the
to control the type of default and only
WAN conditioning allowed value is
applied to WAN upon GFPCMF
LAN defects (Rx Loss
of Signal, Rx Loss of
Sync, AN time-out, Rx
Idle, Link Down) and
CP Fail. Possible
values are NONE or a
combination of:
GFPCMF,
GFPCMFUSER,
GFP10BERR, UNEQ,
AIS and NILTR.
curr-vc-del M Current differential
delay in microseconds.
If the value cannot be
retrieved, UNKNOWN
will be displayed. If
VCAT is disabled or if
WAN is not cross-
connected, NA (Not
Applicable) will be
displayed.
direction O Monitoring GFP layer
in receive or transmit
direction
e-type O Encapsulation scheme
used in customer
frames
expected-upi O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 40GMUX,
attribute is used for 2x10G OTR, 4x10G
Expected UPI OTR, and 10GOTSC
card
exp-pt O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 10GOTSC
attribute is used for card
Expected PT
fcs O Frame Checksum. For The MAPPING,
MAPPING=POS, value MAGICNUM, FCS,
can be 16 or 32. For LCM and LANFCS
MAPPING=GFP-F, attributes must always
value can be 0 or 32. be edited as a group
For MAPPING=GFP-T, (all of them must
only possible value is always be present).
0. Any invalid
combination will be
rejected.
fcs-err-frames O This attribute is used
to specify whether to
keep FCS-errored
frames or Ethernet
frames end-to-end or
to discard them.
gfp-cmf-upi O HEX value in the range
0x03-0xFF. UPI to be
transmitted in GFP
client management
frames.
gfp-rfi O The state of the
transmission of GFP
Client Signal Fail
(CSF) CMFs.
gfp-rfi-upi O The provisioned UPI
value to be transmitted
on WAN link down.
gfp-rt-delay O DISABLE means the
ping CMFs used for
RTDELAY calculation
and Distance
Exceeded Alarm will
no longer be sent. This
implies RTDELAY will
always display
UNKNOWN and the
Distance Exceeded
Alarm will never raise.
if-type O The type of the WAN
facility being queried
lan-fcs O Indicates whether the The MAPPING,
LAN FCS is included in MAGICNUM, FCS,
the encapsulated LCM and LANFCS
frame (for both the attributes must always
ingress and egress be edited as a group
direction). Enable (all of them must
indicates the LAN FCS always be present).
is included. Default Any invalid
value is Enable for combination will be
MAPPING=POS, and rejected.
Disable for
MAPPING=GFP-F or
GFP-T. For
MAPPING=GFP-F or
GFP-T, only possible
value is Disable.
lcas M Link Capacity
Adjustment Scheme
Mode
lcm O Link Connectivity The MAPPING,
Monitor. In some MAGICNUM, FCS,
circumstances it may LCM and LANFCS
be desirable to disable attributes must always
the link continuity be edited as a group
monitor (LCM). When (all of them must
enabled, LCM sends always be present).
an echo request every Any invalid
second. If more than combination will be
five echo requests are rejected.
transmitted without
receiving an echo
response, the PPP
operational OSI state
becomes disabled, and
PPP attempts to re-
establish the link
connection via LCP
configuration request
packets. Default value
is Enable for
MAPPING=POS, and
Disable for
MAPPING=GFP-F or
GFP-T. For
MAPPING=GFP-F or
GFP-T, only possible
value is Disable.
loop-detect O Loopback Detection Must be in CFPRF 7,
using SONMP. 8, or 10 for L2SS and
CFPRF 7, 8, 10, 11,
12, 13 for 20GL2SS.
mac O 48-bit Ethernet MAC
address displayed as
12 alphanumeric
characters. Unique to
each facility.
mac-option O The MAC provisioning
option
magic-num O Enables or disables The MAPPING,
the use of a magic MAGICNUM, FCS,
number to distinguish LCM and LANFCS
between two peers attributes must always
and detect error be edited as a group
conditions. Can be (all of them must
used to determine always be present).
whether trying to Any invalid
establish a link with combination will be
one self. Default value rejected.
is Enable for
MAPPING=POS, and
Disable for
MAPPING=GFP-F or
GFP-T. For
MAPPING=GFP-F or
GFP-T, only possible
value is Disable.
mapping M Packet mapping into
SONET/SDH
max-vc-del M Maximum differential
delay supported by the
port in microseconds.
If the value cannot be
retrieved, UNKNOWN
will be displayed.
mode M Indicates the current Derived from the
mode (either SONET equivalent ED/RTRV-
or SDH). SYS attribute.
ncp M Used to indicate the
Network Control
Protocol used. BCP is
returned when
MAPPING=POS, and
NONE is returned
when
MAPPING=GFP=F or
GFP-T.
opu2-resvd O This attribute is used
to specify whether to
use the 7 unused
bytes of the OPU2
overhead for payload
or not.
os-tran O This attribute is used
to specify whether the
WAN facility supports
Ordered Set
Transparency for
G704.1 compliance.
pdh-type M L Accociated PDH
channel type
pdh-vli O This attribute is used
to specify VLI octet
usage for PDH WANs.
VLI=Vcat Lcas
Interworking, the
concatenation
overhead octet.
policing O Indicates whether
policing will be done
on the given port
preamble O This attribute is used
to specify whether to
use the preamble at
beginning of GFP
frame or throw it away.
The preamble is 8
bytes in total (7 bytes +
1 byte sfd).
prov-rx-units M Indicate the current
number of provisioned
members in the
receive direction.
prov-units M Used to indicate the Derived from the
number of provisioned cross-connections
bandwidth units (of assigned to that WAN
rate specified by the facility.
RATE attribute).
Number of provisioned
bandwidth units (RATE
attributes). For
contiguous
concatenation,
allowable values are
either 0 or 1. The
information is derived
from the cross
connection(s).
q-grp-1 O The AID of the queue
group profile (QGRP-
shelf-profileNo) to be
used for queue group
1.
q-grp-2 O The AID of the queue
group profile (QGRP-
shelf-profileNo) to be
used for queue group
2.
rate M SONET/SDH Basic
rate (derived from
SONET/SDH cross-
connections)
received-pt O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 10GOTSC
attribute is used for card
Received PT
received-upi O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 40GMUX,
attribute is used for 2x10G OTR, 4x10G
Received UPI OTR, and 10GOTSC
card
reserved O Specify if the facility is
being reserved for
packet SNC's
round-trip-delay M Round Trip Delay in Always returns
microseconds. If the UNKNOWN for L2SS,
value cannot be L2SS PDH, L2RPR
retrieved, UNKNOWN and 20GL2SS cards
will be displayed.
rx-cos-profile O The AID of the port RX
COS Profile
(RXCOSPRF-shelf-
profileNo)
scramble M Used to control
payload X^43+1
payload scrambling.
snmp-index O Identifies the index of range of values from 0
the equivalent entry in to 2^32-1
the SNMP interfaces
MIB group
supported-term-pt O Facility AID format.
The supporting
Termination Point.
tx-cos-profile O The AID of the port TX
COS Profile
(TXCOSPRF-shelf-
profileNo)
tx-pt O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 10GOTSC
attribute is used for card
Transmitted PT
tx-upi O HEX value in the range Only applicable to the
0x00-0xFF. This WAN on 40GMUX and
attribute is used for 10GOTSC card
Transmitted UPI
user-rx-cos O The IPHB value to
map the untagged
frames
vcat M L SONET/SDH
concatenation
wan-cap O This attribute indicates
the capacity of the
WAN port
pst M Identify the primary
state
sst M L Identify the secondary
state
AID Descriptions
AID Type Format Values
RLA OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
Input Parameter Description
Parameter Value Description Notes
dm-enable YES
NO
rx-path-loss DECIMAL The Received Span The loss will be of the
Loss in dB. format "xx.xx" and dB
will be assumed.
sd-th INT
(4-10)
AID Descriptions
AID Type Format Values
RLA OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
Input Parameter Description
Parameter Value Description Notes
dm-enable YES, NO Specify if delay
measurement is
enable.
rx-path-loss DECIMAL The Received Span The loss will be of the
Loss in dB. format "xx.xx" and dB
will be assumed.
sd-th INT
(4-10)
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON (6500-T12)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12)
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON (6500-T24)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24)
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON (6500-T12) port
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON (6500-T24) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
(6500-T12) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
(6500-T24) port
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON (6500-T12)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12)
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON (6500-T24)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24)
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON (6500-T12) port
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON (6500-T24) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
(6500-T12) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
(6500-T24) port
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON (6500-T12)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12)
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON (6500-T24)
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24)
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON (6500-T12) port
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON (6500-T24) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
(6500-T12) port
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
(6500-T24) port
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
Input Parameter Description
Parameter Value Description Notes
avg-targ-power DECIMAL Average Wavlength The target will be of
Target Power in dBm. the format "xx.x" and
dBm will be assumed.
los-thresh INT Loss of Signal n/a
Threshold
mode LOSS Control to Loss Mode.
TOP Control to Power
Mode.
targ-loss DECIMAL Target Loss in dB. The target will be of
the format "xx.x" and
dB will be assumed.
targ-pad string Defines the total loss
targeted on the span
or mid-stage
targ-peak-power DECIMAL Target peak Power in The target will be of
dBm. the format "xx.x" and
dBm will be assumed.
targ-power DECIMAL Target Power in dBm. The target will be of
the format "xx.x" and
dBm will be assumed.
voa-reset-required TRUE
FALSE
pst IS In Service
IS-ANR In Service - Abnormal
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
OOS-AU Out-of-service
autonomous from a
failure detected point
of view. It is not out of
service from a state
point of view. Alarm is
raised if the entity is
not able to perform its
provisioned functions
OOS-AUMA Out-of-service
autonomous
management - the
entity is not able to
perform its provisioned
functions and is
purposefully removed
from service
OOS-MAANR Out-of-service
maintenance -
abnormal.
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
MT Maintenance
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
Input Parameter Description
Parameter Value Description Notes
sst MT Maintenance
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
Input Parameter Description
Parameter Value Description Notes
avg-targ-power DECIMAL Average Wavlength The target will be of
Target Power in dBm. the format "xx.x" and
dBm will be assumed.
los-thresh INT Loss of Signal
Threshold
mode LOSS Control to Loss Mode.
TOP Control to Power
Mode.
targ-loss DECIMAL Target Loss in dB. The target will be of
the format "xx.x" and
dB will be assumed.
targ-pad string Defines the total loss
targeted on the span
or mid-stage
targ-peak-power DECIMAL Target peak Power in The target will be of
dBm. the format "xx.x" and
dBm will be assumed.
targ-power DECIMAL Target Power in dBm. The target will be of
the format "xx.x" and
dBm will be assumed.
voa-reset-required TRUE
FALSE
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
Input Parameter Description
Parameter Value Description Notes
carrier-centering-mode MODE1 Laser centering mode
1
MODE2 Laser centering mode
2
MODE3 Laser centering mode
3
UNKNOWN Laser centering mode
UNKNOWN
UNAVAILABLE
ccda ON Turn ON Channel
Contention Detection
and Avoidance
OFF Turn OFF Channel
Contention Dectection
and Avoidance
UNKNOWN UNKNOWN Channel
Contention Dectection
and Avoidance
UNAVAILABLE
cond-type NONE There is no
conditioning.
LASEROFF The conditioning is to
turn off the transmitting
laser.
TXOFF The conditioning is to
turn off the transmitter.
differential-encoding NONE TR Control NONE
HARD TR Control HARD
SOFT TR Control SOFT
XD TR Control XD
enm-prov MODE1 ENM provisioning
mode 1 - STANDARD
MODE2 ENM provisioning
mode 2 - ENHANCED
AUTO ENM provisioning auto
- COMPATIBLE,
RTRV only
UNKNOWN ENM default value for
RX and TX ENM,
RTRV only
exp-res-time-prov INT Provisioned
(0-100) Acquisition Holdoff
Time
fec-frmt QFEC QFEC
RS8 RS8
EFEC EFEC
LDPCFEC LDPCFEC
RS10_KP4 RS10_KP4
TFEC TFEC
frr DISABLED DISABLED Mode
ENABLED ENABLED Mode
frr-config MATCHEDCD Matched Chromatic
Dispersion
DIVERSECD2 Diverse Chromatic
Dispersion 2 Paths
frr-path1-disp string OCH FRR Link Range = -80000 to
Dispersion for Path 1 +80000 for 100G WL3
OCLD and 100G WL3i
PKTOTN, -50000 to
+50000 for 40G
OCLD, Units in ps/nm
frr-path2-disp string OCH FRR Link Range = -80000 to
Dispersion for Path 2 +80000 for 100G WL3
OCLD and 100G WL3i
PKTOTN, -50000 to
+50000 for 40G
OCLD, Units in ps/nm
label string User specified Label
( min len=0 max len=64 )
laser-centering-range string Sets laser centering Laser centering range
range in GHz
laser-freq-thr DECIMAL Laser Frequency The target will be of
(0-3.0) Threshold the format +/- x.x and
GHz will be assumed.
laser-off-mode MODE1
MODE2
laser-status ON Laser Status is ON.
OFF Laser Status is OFF.
line-fail LINE_PATH_UNI
LINE_UNI
LINE_PATH_BI
LINE_BI
linkOpt-mode LNKSTDMODE
LNKSNRMODE
LNKTRACKINGMODE
LNKSPECTRALMODE
LNKLATENCYMODE
LNKNRBWCHMODE
LNKNONLCHMODE
LNKFLINEMODE
LNKRSVMODE1
LNKRSVMODE2
LNKRSVMODE3
CUSTOM
UNKNOWN
35GBAUD_TEST 35GBaud testing mode
for internal use
UNAVAILABLE
lnkCustom1 DEFAULT
lnkCustom2 DEFAULT
lqs-managed YES Liquid Spectrum
managed
NO Not Liquid Spectrum
managed
UNKNOWN Liquid Spectrum
managed unknown
modem-class TERRESTRIAL
SUBMARINE
och-tx-blanking ON Turn ON TX Power in
Reduced State
OFF Turn OFF TX Power in
Reduced State
UNKNOWN UNKNOWN TX Power
in Reduced State
UNAVAILABLE
optimize-mode OPTIMIZATIONMODE1 for best reach
performance
OPTIMIZATIONMODE2 for best latency
performance
OPTIMIZATIONMODE3 for fast tracking
OPTIMIZATIONMODE4 for improved tracking
OPTIMIZATIONMODE5 for tracking mode5
OPTIMIZATIONMODE6 for tracking mode6
OPTIMIZATIONMODE7 for tracking mode7
OPTIMIZATIONMODE8 for tracking mode8
OPTIMIZATIONMODE9 for tracking mode9
OPTIMIZATIONMODE10 for tracking mode10
OPTIMIZATIONMODE11 for tracking mode11
OPTIMIZATIONMODE12 for tracking mode12
OPTIMIZATIONMODE13 for tracking mode13
OPTIMIZATIONMODE14 for tracking mode14
p-aid PTP PTP- PTP- Specify the Prime PTP Not valid when PTP
(6500- shelf- [0..992]- AID. Role is Prime, it's
T12) slot- [1..12]- mandatory when PTP
port [1..40] Role is Member
PTP PTP- PTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port [1..40]
path-disp-prov string Path Dispersion Value Path Dispersion
ranges and|or defaults
are card specific for
TXMODE Automatic,
FIXEDTX and
EXPERT
pre-fec-sd-th-lev DECIMAL Pre-FEC Signal The target will be of
(-1.00-3.50) Degrade Threshold the format +/- x.x and
dBQ will be assumed.
pre-fec-sf-th-lev DECIMAL Pre-FEC Signal Fail The target will be of
(-1.00-1.00) Threshold the format +/- x.x and
dBQ will be assumed.
pwr-bal-ctlr DISABLED Power Balance
Controller Disabled
ENABLED Power Balance
Controller Enabled
pwr-bal-offset string Provisioned Power Power Balance ranges
Balance Offset in dB are card specific
(xx.x)
reach-class TERBASE Maximum Reach Basic terrestrial
1~1000 Km Terrestrial license is required for
up to 1000 KM
TER2 Maximum Reach Need terrestrial license
1~2000 Km Terrestrial class1 for up to 2000
KM
TER5 Maximum Reach Need terrestrial license
1~5000 Km Terrestrial class2 for up to 5000
KM
TER8 Maximum Reach Need terrestrial license
5001~9000 Km class2 for up to 8000
Terrestrial KM
SUBBASE Maximum Reach Basic submarine
1~2000 Km Submarine license is required for
up to 2000 KM
SUB9 Maximum Reach Need submarine
1~9000 Km Submarine license class1 for up to
9000 KM
SUB14 Maximum Reach Need submarine
1~14000 Km license class2 for up to
Submarine 14000 KM
TER1P5 Maximum Reach Need terrestrial license
1~1500 Km Terrestrial class1 for up to 1500
KM
TER2P1 Maximum Reach Need terrestrial license
1~2100 Km Terrestrial class2 for up to 2100
KM
TER3 Maximum Reach Need terrestrial license
1~3000 Km Terrestrial class2 for up to 3000
KM
TER4 Maximum Reach Need terrestrial license
1~4000 Km Terrestrial class2 for up to 4000
KM
WL5NBASE Maximum Reach Need WL5N base
1~250 Km WL5N license for up to 250
KM
WL5N0P5 Maximum Reach Need WL5N license
1~500 Km WL5N class1 for up to 500
KM
WL5N1 Maximum Reach Need WL5N license
1~1000 Km WL5N class2 for up to 1000
KM
WL5N2 Maximum Reach Need WL5N license
1~2000 Km WL5N class3 for up to 1000
KM
WL5ETERBASE Maximum Reach Need WL5e
1~250 Km WL5E base(default)
terrestrial license for
up to 250 KM
WL5ETER0P5 Maximum Reach Need WL5e terristreal
1~500 Km WL5E license class0P5 for
up to 500 KM
WL5ETER1 Maximum Reach Need WL5e terristreal
1~1000 Km WL5E license class1 for up to
1000 KM
WL5ETER2 Maximum Reach Need WL5e terristreal
1~2000 Km WL5E license class2 for up to
2000 KM
WL5ETER3 Maximum Reach Need WL5e terristreal
1~3000 Km WL5E license class3 for up to
3000 KM
WL5ETER4 Maximum Reach Need WL5e terristreal
1~4000 Km WL5E license class4 for up to
4000 KM
WL5ETER5 Maximum Reach Need WL5e terristreal
1~5000 Km WL5E license class5 for up to
5000 KM
WL5ETER8 Maximum Reach Need WL5e terristreal
1~8000 Km WL5E license class8 for up to
8000 KM
WL5ESUBBASE Maximum Reach Need WL5e
1~3500 Km Submarine base(default)
WL5E submarine license for
up to 3500 KM
WL5ESUB9 Maximum Reach Need WL5e submarine
1~9000 Km Submarine license class9 for up to
WL5E 9000 KM
WL5ESUB14 Maximum Reach Need WL5e submarine
1~14000 Km license class14 for up
Submarine WL5E to 14000 KM
WL5ETER2P1 Maximum Reach Need WL5e terristreal
1~2100 Km WL5E license class2P1 for
up to 2100 KM
TER0P25 Maximum Reach Need WLAi terristreal
1~250 Km WLAi license is required for
up to 250 KM
reach-type REACHCD1
REACHCD2
REACHCD3
REACHCD4
REACHCD5
REACHCDRSV1
REACHCDRSV2
REACHCDRSV3
CUSTOM
role PRIME PTP is prime port in
OTUCn-M
configuration
MEMBER PTP is memver port in
OTUCn-M
configuration
rotation DISABLED Disable OCH Jones
Rotation Feature
ENABLED Enable OCH Jones
Rotation Feature
rx-ch-pwr-h-thr string Provisioned Rx Range from 1.0 to 10.0
channel Power OOR
high threshold
rx-ch-pwr-l-thr string Provisioned Rx Range from -30.0 to
channel Power OOR -1.0
low threshold
rx-pwr-h-thr string Provisioned Rx Power Range from 1.0 to 10.0
OOR high threshold
rx-pwr-l-thr string Provisioned Rx Power Range from -30.0 to
OOR low threshold -1.0
rx-pwr-thr-prov ON Use of provisioned
thresholds is on
OFF Use of provisioned
thresholds is off
ser-path-disp-max-prov string Provisioned Path
Dispersion Maximum
for the SEARCH mode
ser-path-disp-min-prov string Provisioned Path
Dispersion Minimum
for the SEARCH mode
service-type OTU4 OTU TTP with rate
OTU4
OTU3E2 OTU TTP with rate
OTU3E2
OTU3 OTU TTP with rate
OTU3
OTU2 OTU TTP with rate
OTU2
OTU2E OTU TTP with rate
OTU2E
OTU1 OTU TTP with rate
OTU1
OC768 STTP (SONET) with
rate OC768
STM256 STTP (SDH) with rate
STM256
OC192 STTP (SONET) with
rate OC192
STM64 STTP (SDH) with rate
STM64
OC48 STTP (SONET) with
rate OC48
STM16 STTP (SDH) with rate
STM16
OC12 STTP (SONET) with
rate OC12
STM4 STTP (SDH) with rate
STM4
OC3 STTP (SONET) with
rate OC3
STM1 STTP (SDH) with rate
STM1
ETH100M ETTP with rate
ETH100M
ETH1G ETTP with rate ETH1G
ETH10G ETTP with rate
ETH10G
ETH40G ETTP with rate
ETH40G
ETH100G ETTP with rate
ETH100G
ETH100MPKT ETTP with rate
ETH100M PKT
ETH1GPKT ETTP with rate ETH1G
PKT
ETH10GPKT ETTP with rate
ETH10G PKT
ETH40GPKT ETTP with rate
ETH40G PKT
ETH100GPKT ETTP with rate
ETH100G PKT
ETH10GFLEX ETTP with rate
ETH10G FLEX
ETH40GFLEX ETTP with rate
ETH40G FLEX
ETH100GFLEX ETTP with rate
ETH100G FLEX
OTUC2-40 OTUTTP with OTUC2-
40 rate
OTUC2-30 OTUTTP with OTUC2-
30 rate
OTUC4-80 OTUTTP with OTUC4-
80 rate
OTUC4-60 OTUTTP with OTUC4-
60 rate
OTU2REGEN OTUTTP REGEN with
rate OTU2
OTU2EREGEN OTUTTP REGEN with
rate OTU2E
UNKNOWN OTUTTP with
UNKNOWN rate
EC1 PTS STTP with rate
EC1TERM
ETH10M PTS ETTP rate
ETH10M
spli-mgmt ON Port is Manageable by
SPLI
OFF Port is not Manageable
by SPLI
trans-mode UNKNOWN
UNAVAILABLE
35GBAUD_100G 37.87 ~ 38.46 GHz,
35GBaud 100G LH
application
35GBAUD_150G 37.87 ~ 38.46 GHz,
35GBaud 150G Metro
application
35GBAUD_200G 37.87 ~ 38.46 GHz,
35GBaud 200G Metro
application
35GBAUD_250G 37.87 ~ 38.46 GHz,
35GBaud 250G Metro
application
35GBAUD_TEST 37.87 ~ 38.46 GHz,
35GBaud testing mode
for internal use
56GBAUD_100G 60.59 ~ 61.53 GHz,
56GBaud 100G ULH
application
56GBAUD_150G 60.59 ~ 61.53 GHz,
56GBaud 150G ULH
application
56GBAUD_200G 60.59 ~ 61.53 GHz,
56GBaud 200G LH
application
56GBAUD_250G 60.59 ~ 61.53 GHz,
56GBaud 250G LH
application
56GBAUD_300G 60.59 ~ 61.53 GHz,
56GBaud 300G Metro
application
56GBAUD_350G 60.59 ~ 61.53 GHz,
56GBaud 350G Metro
application
56GBAUD_400G 60.59 ~ 61.53 GHz,
56GBaud 400G Metro
application
RSV1
RSV2
RSV3
CUSTOM
28GBAUD_100G
32GBAUD_100G
32GBAUD_200G
FOIC1_2
FOIC1_4
FOIC2_4
FOIC4_8
100GBASE_R
200GBASE_R
400GBASE_R
95GBAUD_200G_O 95 GBaud 200G OTN
Transcoded
95GBAUD_250G_O 95 GBaud 250G OTN
Transcoded
95GBAUD_300G_O 95 GBaud 300G OTN
Transcoded
95GBAUD_350G_O 95 GBaud 350G OTN
Transcoded
95GBAUD_400G_O 95 GBaud 400G OTN
Transcoded
95GBAUD_450G_O 95 GBaud 450G OTN
Transcoded
95GBAUD_500G_O 95 GBaud 500G OTN
Transcoded
95GBAUD_550G_O 95 GBaud 550G OTN
Transcoded
95GBAUD_600G_O 95 GBaud 600G OTN
Transcoded
95GBAUD_650G_O 95 GBaud 650G OTN
Transcoded
95GBAUD_700G_O 95 GBaud 700G OTN
Transcoded
95GBAUD_750G_O 95 GBaud 750G OTN
Transcoded
95GBAUD_800G_O 95 GBaud 800G OTN
Transcoded
91P6GBAUD_200G_O 91.6 GBaud 200G
OTN Transcoded
91P6GBAUD_250G_O 91.6 GBaud 250G
OTN Transcoded
91P6GBAUD_300G_O 91.6 GBaud 300G
OTN Transcoded
91P6GBAUD_350G_O 91.6 GBaud 350G
OTN Transcoded
91P6GBAUD_400G_O 91.6 GBaud 400G
OTN Transcoded
91P6GBAUD_450G_O 91.6 GBaud 450G
OTN Transcoded
91P6GBAUD_500G_O 91.6 GBaud 500G
OTN Transcoded
91P6GBAUD_550G_O 91.6 GBaud 550G
OTN Transcoded
91P6GBAUD_600G_O 91.6 GBaud 600G
OTN Transcoded
91P6GBAUD_650G_O 91.6 GBaud 650G
OTN Transcoded
91P6GBAUD_700G_O 91.6 GBaud 700G
OTN Transcoded
91P6GBAUD_750G_O 91.6 GBaud 750G
OTN Transcoded
91P6GBAUD_800G_O 91.6 GBaud 800G
OTN Transcoded
89P3GBAUD_200G_O 89.3 GBaud 200G
OTN Transcoded
89P3GBAUD_250G_O 89.3 GBaud 250G
OTN Transcoded
89P3GBAUD_300G_O 89.3 GBaud 300G
OTN Transcoded
89P3GBAUD_350G_O 89.3 GBaud 350G
OTN Transcoded
89P3GBAUD_400G_O 89.3 GBaud 400G
OTN Transcoded
89P3GBAUD_450G_O 89.3 GBaud 450G
OTN Transcoded
89P3GBAUD_500G_O 89.3 GBaud 500G
OTN Transcoded
89P3GBAUD_550G_O 89.3 GBaud 550G
OTN Transcoded
89P3GBAUD_600G_O 89.3 GBaud 600G
OTN Transcoded
89P3GBAUD_650G_O 89.3 GBaud 650G
OTN Transcoded
89P3GBAUD_700G_O 89.3 GBaud 700G
OTN Transcoded
89P3GBAUD_750G_O 89.3 GBaud 750G
OTN Transcoded
89P3GBAUD_800G_O 89.3 GBaud 800G
OTN Transcoded
71P3GBAUD_200G_O 71.3 GBaud 200G
OTN Transcoded
71P3GBAUD_250G_O 71.3 GBaud 250G
OTN Transcoded
71P3GBAUD_300G_O 71.3 GBaud 300G
OTN Transcoded
71P3GBAUD_350G_O 71.3 GBaud 350G
OTN Transcoded
71P3GBAUD_400G_O 71.3 GBaud 400G
OTN Transcoded
71P3GBAUD_450G_O 71.3 GBaud 450G
OTN Transcoded
71P3GBAUD_500G_O 71.3 GBaud 500G
OTN Transcoded
71P3GBAUD_550G_O 71.3 GBaud 550G
OTN Transcoded
71P3GBAUD_600G_O 71.3 GBaud 600G
OTN Transcoded
69P5GBAUD_200G_O 69.5 GBaud 200G
OTN Transcoded
69P5GBAUD_250G_O 69.5 GBaud 250G
OTN Transcoded
69P5GBAUD_300G_O 69.5 GBaud 300G
OTN Transcoded
69P5GBAUD_350G_O 69.5 GBaud 350G
OTN Transcoded
69P5GBAUD_400G_O 69.5 GBaud 400G
OTN Transcoded
69P5GBAUD_450G_O 69.5 GBaud 450G
OTN Transcoded
69P5GBAUD_500G_O 69.5 GBaud 500G
OTN Transcoded
69P5GBAUD_550G_O 69.5 GBaud 550G
OTN Transcoded
69P5GBAUD_600G_O 69.5 GBaud 600G
OTN Transcoded
95GBAUD_200G_E 95 GBaud 200G
Ethernet Transcoded
95GBAUD_250G_E 95 GBaud 250G
Ethernet Transcoded
95GBAUD_300G_E 95 GBaud 300G
Ethernet Transcoded
95GBAUD_350G_E 95 GBaud 350G
Ethernet Transcoded
95GBAUD_400G_E 95 GBaud 400G
Ethernet Transcoded
95GBAUD_450G_E 95 GBaud 450G
Ethernet Transcoded
95GBAUD_500G_E 95 GBaud 500G
Ethernet Transcoded
95GBAUD_550G_E 95 GBaud 550G
Ethernet Transcoded
95GBAUD_600G_E 95 GBaud 600G
Ethernet Transcoded
95GBAUD_650G_E 95 GBaud 650G
Ethernet Transcoded
95GBAUD_700G_E 95 GBaud 600G
Ethernet Transcoded
95GBAUD_750G_E 95 GBaud 750G
Ethernet Transcoded
95GBAUD_800G_E 95 GBaud 800G
Ethernet Transcoded
91P6GBAUD_200G_E 91.6 GBaud 200G
Ethernet Transcoded
91P6GBAUD_250G_E 91.6 GBaud 250G
Ethernet Transcoded
91P6GBAUD_300G_E 91.6 GBaud 300G
Ethernet Transcoded
91P6GBAUD_350G_E 91.6 GBaud 350G
Ethernet Transcoded
91P6GBAUD_400G_E 91.6 GBaud 400G
Ethernet Transcoded
91P6GBAUD_450G_E 91.6 GBaud 450G
Ethernet Transcoded
91P6GBAUD_500G_E 91.6 GBaud 500G
Ethernet Transcoded
91P6GBAUD_550G_E 91.6 GBaud 550G
Ethernet Transcoded
91P6GBAUD_600G_E 91.6 GBaud 600G
Ethernet Transcoded
91P6GBAUD_650G_E 91.6 GBaud 650G
Ethernet Transcoded
91P6GBAUD_700G_E 91.6 GBaud 700G
Ethernet Transcoded
91P6GBAUD_750G_E 91.6 GBaud 750G
Ethernet Transcoded
91P6GBAUD_800G_E 91.6 GBaud 800G
Ethernet Transcoded
89P3GBAUD_200G_E 89.3 GBaud 200G
Ethernet Transcoded
89P3GBAUD_250G_E 89.3 GBaud 250G
Ethernet Transcoded
89P3GBAUD_300G_E 89.3 GBaud 300G
Ethernet Transcoded
89P3GBAUD_350G_E 89.3 GBaud 350G
Ethernet Transcoded
89P3GBAUD_400G_E 89.3 GBaud 400G
Ethernet Transcoded
89P3GBAUD_450G_E 89.3 GBaud 450G
Ethernet Transcoded
89P3GBAUD_500G_E 89.3 GBaud 500G
Ethernet Transcoded
89P3GBAUD_550G_E 89.3 GBaud 550G
Ethernet Transcoded
89P3GBAUD_600G_E 89.3 GBaud 600G
Ethernet Transcoded
89P3GBAUD_650G_E 89.3 GBaud 650G
Ethernet Transcoded
89P3GBAUD_700G_E 89.3 GBaud 700G
Ethernet Transcoded
89P3GBAUD_750G_E 89.3 GBaud 750G
Ethernet Transcoded
89P3GBAUD_800G_E 89.3 GBaud 800G
Ethernet Transcoded
71P3GBAUD_200G_E 71.3 GBaud 200G
Ethernet Transcoded
71P3GBAUD_250G_E 71.3 GBaud 250G
Ethernet Transcoded
71P3GBAUD_300G_E 71.3 GBaud 300G
Ethernet Transcoded
71P3GBAUD_350G_E 71.3 GBaud 350G
Ethernet Transcoded
71P3GBAUD_400G_E 71.3 GBaud 400G
Ethernet Transcoded
71P3GBAUD_450G_E 71.3 GBaud 450G
Ethernet Transcoded
71P3GBAUD_500G_E 71.3 GBaud 500G
Ethernet Transcoded
71P3GBAUD_550G_E 71.3 GBaud 550G
Ethernet Transcoded
71P3GBAUD_600G_E 71.3 GBaud 600G
Ethernet Transcoded
69P5GBAUD_200G_E 69.5 GBaud 200G
Ethernet Transcoded
69P5GBAUD_250G_E 69.5 GBaud 250G
Ethernet Transcoded
69P5GBAUD_300G_E 69.5 GBaud 300G
Ethernet Transcoded
69P5GBAUD_350G_E 69.5 GBaud 350G
Ethernet Transcoded
69P5GBAUD_400G_E 69.5 GBaud 400G
Ethernet Transcoded
69P5GBAUD_450G_E 69.5 GBaud 450G
Ethernet Transcoded
69P5GBAUD_500G_E 69.5 GBaud 500G
Ethernet Transcoded
69P5GBAUD_550G_E 69.5 GBaud 550G
Ethernet Transcoded
69P5GBAUD_600G_E 69.5 GBaud 600G
Ethernet Transcoded
95GBAUD_225G_O 95 GBaud 225G OTN
Transcoded
95GBAUD_225G_E 95 GBaud 225G
Ethernet Transcoded
95GBAUD_275G_O 95 GBaud 275G OTN
Transcoded
95GBAUD_275G_E 95 GBaud 275G
Ethernet Transcoded
95GBAUD_325G_O 95 GBaud 325G OTN
Transcoded
95GBAUD_325G_E 95 GBaud 325G
Ethernet Transcoded
95GBAUD_375G_O 95 GBaud 375G OTN
Transcoded
95GBAUD_375G_E 95 GBaud 375G
Ethernet Transcoded
95GBAUD_425G_O 95 GBaud 425G OTN
Transcoded
95GBAUD_425G_E 95 GBaud 425G
Ethernet Transcoded
95GBAUD_475G_O 95 GBaud 475G OTN
Transcoded
95GBAUD_475G_E 95 GBaud 475G
Ethernet Transcoded
95GBAUD_525G_O 95 GBaud 525G OTN
Transcoded
95GBAUD_525G_E 95 GBaud 525G
Ethernet Transcoded
95GBAUD_575G_O 95 GBaud 575G OTN
Transcoded
95GBAUD_575G_E 95 GBaud 575G
Ethernet Transcoded
95GBAUD_625G_O 95 GBaud 625G OTN
Transcoded
95GBAUD_625G_E 95 GBaud 625G
Ethernet Transcoded
95GBAUD_675G_O 95 GBaud 675G OTN
Transcoded
95GBAUD_675G_E 95 GBaud 675G
Ethernet Transcoded
95GBAUD_725G_O 95 GBaud 725G OTN
Transcoded
95GBAUD_725G_E 95 GBaud 725G
Ethernet Transcoded
95GBAUD_775G_O 95 GBaud 775G OTN
Transcoded
95GBAUD_775G_E 95 GBaud 775G
Ethernet Transcoded
91P6GBAUD_225G_O 91.6 GBaud 225G
OTN Transcoded
91P6GBAUD_225G_E 91.6 GBaud 225G
Ethernet Transcoded
91P6GBAUD_275G_O 91.6 GBaud 275G
OTN Transcoded
91P6GBAUD_275G_E 91.6 GBaud 275G
Ethernet Transcoded
91P6GBAUD_325G_O 91.6 GBaud 325G
OTN Transcoded
91P6GBAUD_325G_E 91.6 GBaud 325G
Ethernet Transcoded
91P6GBAUD_375G_O 91.6 GBaud 375G
OTN Transcoded
91P6GBAUD_375G_E 91.6 GBaud 375G
Ethernet Transcoded
91P6GBAUD_425G_O 91.6 GBaud 425G
OTN Transcoded
91P6GBAUD_425G_E 91.6 GBaud 425G
Ethernet Transcoded
91P6GBAUD_475G_O 91.6 GBaud 475G
OTN Transcoded
91P6GBAUD_475G_E 91.6 GBaud 475G
Ethernet Transcoded
91P6GBAUD_525G_O 91.6 GBaud 525G
OTN Transcoded
91P6GBAUD_525G_E 91.6 GBaud 525G
Ethernet Transcoded
91P6GBAUD_575G_O 91.6 GBaud 575G
OTN Transcoded
91P6GBAUD_575G_E 91.6 GBaud 575G
Ethernet Transcoded
91P6GBAUD_625G_O 91.6 GBaud 625G
OTN Transcoded
91P6GBAUD_625G_E 91.6 GBaud 625G
Ethernet Transcoded
91P6GBAUD_675G_O 91.6 GBaud 675G
OTN Transcoded
91P6GBAUD_675G_E 91.6 GBaud 675G
Ethernet Transcoded
91P6GBAUD_725G_O 91.6 GBaud 725G
OTN Transcoded
91P6GBAUD_725G_E 91.6 GBaud 725G
Ethernet Transcoded
91P6GBAUD_775G_O 91.6 GBaud 775G
OTN Transcoded
91P6GBAUD_775G_E 91.6 GBaud 775G
Ethernet Transcoded
71P3GBAUD_225G_O 71.3 GBaud 225G
OTN Transcoded
71P3GBAUD_225G_E 71.3 GBaud 225G
Ethernet Transcoded
71P3GBAUD_275G_O 71.3 GBaud 275G
OTN Transcoded
71P3GBAUD_275G_E 71.3 GBaud 275G
Ethernet Transcoded
71P3GBAUD_325G_O 71.3 GBaud 325G
OTN Transcoded
71P3GBAUD_325G_E 71.3 GBaud 325G
Ethernet Transcoded
71P3GBAUD_375G_O 71.3 GBaud 375G
OTN Transcoded
71P3GBAUD_375G_E 71.3 GBaud 375G
Ethernet Transcoded
71P3GBAUD_425G_O 71.3 GBaud 425G
OTN Transcoded
71P3GBAUD_425G_E 71.3 GBaud 425G
Ethernet Transcoded
71P3GBAUD_475G_O 71.3 GBaud 475G
OTN Transcoded
71P3GBAUD_475G_E 71.3 GBaud 475G
Ethernet Transcoded
71P3GBAUD_525G_O 71.3 GBaud 525G
OTN Transcoded
71P3GBAUD_525G_E 71.3 GBaud 525G
Ethernet Transcoded
71P3GBAUD_575G_O 71.3 GBaud 575G
OTN Transcoded
71P3GBAUD_575G_E 71.3 GBaud 575G
Ethernet Transcoded
71P3GBAUD_625G_O 71.3 GBaud 625G
OTN Transcoded
71P3GBAUD_625G_E 71.3 GBaud 625G
Ethernet Transcoded
71P3GBAUD_650G_O 71.3 GBaud 650G
OTN Transcoded
71P3GBAUD_650G_E 71.3 GBaud 650G
Ethernet Transcoded
71P3GBAUD_675G_O 71.3 GBaud 675G
OTN Transcoded
71P3GBAUD_675G_E 71.3 GBaud 675G
Ethernet Transcoded
71P3GBAUD_700G_O 71.3 GBaud 700G
OTN Transcoded
71P3GBAUD_700G_E 71.3 GBaud 700G
Ethernet Transcoded
71P3GBAUD_725G_O 71.3 GBaud 725G
OTN Transcoded
71P3GBAUD_725G_E 71.3 GBaud 725G
Ethernet Transcoded
71P3GBAUD_750G_O 71.3 GBaud 750G
OTN Transcoded
71P3GBAUD_750G_E 71.3 GBaud 750G
Ethernet Transcoded
71P3GBAUD_775G_O 71.3 GBaud 775G
OTN Transcoded
71P3GBAUD_775G_E 71.3 GBaud 775G
Ethernet Transcoded
71P3GBAUD_800G_O 71.3 GBaud 800G
OTN Transcoded
71P3GBAUD_800G_E 71.3 GBaud 800G
Ethernet Transcoded
106P9GBAUD_200G_O 106.9 GBaud 200G
OTN Transcoded
106P9GBAUD_200G_E 106.9 GBaud 200G
Ethernet Transcoded
106P9GBAUD_225G_O 106.9 GBaud 225G
OTN Transcoded
106P9GBAUD_225G_E 106.9 GBaud 225G
Ethernet Transcoded
106P9GBAUD_250G_O 106.9 GBaud 250G
OTN Transcoded
106P9GBAUD_250G_E 106.9 GBaud 250G
Ethernet Transcoded
106P9GBAUD_275G_O 106.9 GBaud 275G
OTN Transcoded
106P9GBAUD_275G_E 106.9 GBaud 275G
Ethernet Transcoded
106P9GBAUD_300G_O 106.9 GBaud 300G
OTN Transcoded
106P9GBAUD_300G_E 106.9 GBaud 300G
Ethernet Transcoded
106P9GBAUD_325G_O 106.9 GBaud 325G
OTN Transcoded
106P9GBAUD_325G_E 106.9 GBaud 325G
Ethernet Transcoded
106P9GBAUD_350G_O 106.9 GBaud 350G
OTN Transcoded
106P9GBAUD_350G_E 106.9 GBaud 350G
Ethernet Transcoded
106P9GBAUD_375G_O 106.9 GBaud 375G
OTN Transcoded
106P9GBAUD_375G_E 106.9 GBaud 375G
Ethernet Transcoded
106P9GBAUD_400G_O 106.9 GBaud 400G
OTN Transcoded
106P9GBAUD_400G_E 106.9 GBaud 400G
Ethernet Transcoded
106P9GBAUD_425G_O 106.9 GBaud 425G
OTN Transcoded
106P9GBAUD_425G_E 106.9 GBaud 425G
Ethernet Transcoded
106P9GBAUD_450G_O 106.9 GBaud 450G
OTN Transcoded
106P9GBAUD_450G_E 106.9 GBaud 450G
Ethernet Transcoded
106P9GBAUD_475G_O 106.9 GBaud 475G
OTN Transcoded
106P9GBAUD_475G_E 106.9 GBaud 475G
Ethernet Transcoded
106P9GBAUD_500G_O 106.9 GBaud 500G
OTN Transcoded
106P9GBAUD_500G_E 106.9 GBaud 500G
Ethernet Transcoded
106P9GBAUD_525G_O 106.9 GBaud 525G
OTN Transcoded
106P9GBAUD_525G_E 106.9 GBaud 525G
Ethernet Transcoded
106P9GBAUD_550G_O 106.9 GBaud 550G
OTN Transcoded
106P9GBAUD_550G_E 106.9 GBaud 550G
Ethernet Transcoded
106P9GBAUD_575G_O 106.9 GBaud 575G
OTN Transcoded
106P9GBAUD_575G_E 106.9 GBaud 575G
Ethernet Transcoded
106P9GBAUD_600G_O 106.9 GBaud 600G
OTN Transcoded
106P9GBAUD_600G_E 106.9 GBaud 600G
Ethernet Transcoded
106P9GBAUD_625G_O 106.9 GBaud 625G
OTN Transcoded
106P9GBAUD_625G_E 106.9 GBaud 625G
Ethernet Transcoded
106P9GBAUD_650G_O 106.9 GBaud 650G
OTN Transcoded
106P9GBAUD_650G_E 106.9 GBaud 650G
Ethernet Transcoded
106P9GBAUD_675G_O 106.9 GBaud 675G
OTN Transcoded
106P9GBAUD_675G_E 106.9 GBaud 675G
Ethernet Transcoded
106P9GBAUD_700G_O 106.9 GBaud 700G
OTN Transcoded
106P9GBAUD_700G_E 106.9 GBaud 700G
Ethernet Transcoded
106P9GBAUD_725G_O 106.9 GBaud 725G
OTN Transcoded
106P9GBAUD_725G_E 106.9 GBaud 725G
Ethernet Transcoded
106P9GBAUD_750G_O 106.9 GBaud 750G
OTN Transcoded
106P9GBAUD_750G_E 106.9 GBaud 750G
Ethernet Transcoded
106P9GBAUD_775G_O 106.9 GBaud 775G
OTN Transcoded
106P9GBAUD_775G_E 106.9 GBaud 775G
Ethernet Transcoded
106P9GBAUD_800G_O 106.9 GBaud 800G
OTN Transcoded
106P9GBAUD_800G_E 106.9 GBaud 800G
Ethernet Transcoded
92P6GBAUD_200G_O 92.6 GBaud 200G
OTN Transcoded
92P6GBAUD_200G_E 92.6 GBaud 200G
Ethernet Transcoded
92P6GBAUD_225G_O 92.6 GBaud 225G
OTN Transcoded
92P6GBAUD_225G_E 92.6 GBaud 225G
Ethernet Transcoded
92P6GBAUD_250G_O 92.6 GBaud 250G
OTN Transcoded
92P6GBAUD_250G_E 92.6 GBaud 250G
Ethernet Transcoded
92P6GBAUD_275G_O 92.6 GBaud 275G
OTN Transcoded
92P6GBAUD_275G_E 92.6 GBaud 275G
Ethernet Transcoded
92P6GBAUD_300G_O 92.6 GBaud 300G
OTN Transcoded
92P6GBAUD_300G_E 92.6 GBaud 300G
Ethernet Transcoded
92P6GBAUD_325G_O 92.6 GBaud 325G
OTN Transcoded
92P6GBAUD_325G_E 92.6 GBaud 325G
Ethernet Transcoded
92P6GBAUD_350G_O 92.6 GBaud 350G
OTN Transcoded
92P6GBAUD_350G_E 92.6 GBaud 350G
Ethernet Transcoded
92P6GBAUD_375G_O 92.6 GBaud 375G
OTN Transcoded
92P6GBAUD_375G_E 92.6 GBaud 375G
Ethernet Transcoded
92P6GBAUD_400G_O 92.6 GBaud 400G
OTN Transcoded
92P6GBAUD_400G_E 92.6 GBaud 400G
Ethernet Transcoded
92P6GBAUD_425G_O 92.6 GBaud 425G
OTN Transcoded
92P6GBAUD_425G_E 92.6 GBaud 425G
Ethernet Transcoded
92P6GBAUD_450G_O 92.6 GBaud 450G
OTN Transcoded
92P6GBAUD_450G_E 92.6 GBaud 450G
Ethernet Transcoded
92P6GBAUD_475G_O 92.6 GBaud 475G
OTN Transcoded
92P6GBAUD_475G_E 92.6 GBaud 475G
Ethernet Transcoded
92P6GBAUD_500G_O 92.6 GBaud 500G
OTN Transcoded
92P6GBAUD_500G_E 92.6 GBaud 500G
Ethernet Transcoded
92P6GBAUD_525G_O 92.6 GBaud 525G
OTN Transcoded
92P6GBAUD_525G_E 92.6 GBaud 525G
Ethernet Transcoded
92P6GBAUD_550G_O 92.6 GBaud 550G
OTN Transcoded
92P6GBAUD_550G_E 92.6 GBaud 550G
Ethernet Transcoded
92P6GBAUD_575G_O 92.6 GBaud 575G
OTN Transcoded
92P6GBAUD_575G_E 92.6 GBaud 575G
Ethernet Transcoded
92P6GBAUD_600G_O 92.6 GBaud 600G
OTN Transcoded
92P6GBAUD_600G_E 92.6 GBaud 600G
Ethernet Transcoded
92P6GBAUD_625G_O 92.6 GBaud 625G
OTN Transcoded
92P6GBAUD_625G_E 92.6 GBaud 625G
Ethernet Transcoded
92P6GBAUD_650G_O 92.6 GBaud 650G
OTN Transcoded
92P6GBAUD_650G_E 92.6 GBaud 650G
Ethernet Transcoded
92P6GBAUD_675G_O 92.6 GBaud 675G
OTN Transcoded
92P6GBAUD_675G_E 92.6 GBaud 675G
Ethernet Transcoded
92P6GBAUD_700G_O 92.6 GBaud 700G
OTN Transcoded
92P6GBAUD_700G_E 92.6 GBaud 700G
Ethernet Transcoded
92P6GBAUD_725G_O 92.6 GBaud 725G
OTN Transcoded
92P6GBAUD_725G_E 92.6 GBaud 725G
Ethernet Transcoded
92P6GBAUD_750G_O 92.6 GBaud 750G
OTN Transcoded
92P6GBAUD_750G_E 92.6 GBaud 750G
Ethernet Transcoded
92P6GBAUD_775G_O 92.6 GBaud 775G
OTN Transcoded
92P6GBAUD_775G_E 92.6 GBaud 775G
Ethernet Transcoded
92P6GBAUD_800G_O 92.6 GBaud 800G
OTN Transcoded
92P6GBAUD_800G_E 92.6 GBaud 800G
Ethernet Transcoded
89P3GBAUD_225G_O 89.3 GBaud 225G
OTN Transcoded
89P3GBAUD_225G_E 89.3 GBaud 225G
Ethernet Transcoded
89P3GBAUD_275G_O 89.3 GBaud 275G
OTN Transcoded
89P3GBAUD_275G_E 89.3 GBaud 275G
Ethernet Transcoded
89P3GBAUD_325G_O 89.3 GBaud 325G
OTN Transcoded
89P3GBAUD_325G_E 89.3 GBaud 325G
Ethernet Transcoded
89P3GBAUD_375G_O 89.3 GBaud 375G
OTN Transcoded
89P3GBAUD_375G_E 89.3 GBaud 375G
Ethernet Transcoded
89P3GBAUD_425G_O 89.3 GBaud 425G
OTN Transcoded
89P3GBAUD_425G_E 89.3 GBaud 425G
Ethernet Transcoded
89P3GBAUD_475G_O 89.3 GBaud 475G
OTN Transcoded
89P3GBAUD_475G_E 89.3 GBaud 475G
Ethernet Transcoded
89P3GBAUD_525G_O 89.3 GBaud 525G
OTN Transcoded
89P3GBAUD_525G_E 89.3 GBaud 525G
Ethernet Transcoded
89P3GBAUD_575G_O 89.3 GBaud 575G
OTN Transcoded
89P3GBAUD_575G_E 89.3 GBaud 575G
Ethernet Transcoded
89P3GBAUD_625G_O 89.3 GBaud 625G
OTN Transcoded
89P3GBAUD_625G_E 89.3 GBaud 625G
Ethernet Transcoded
89P3GBAUD_675G_O 89.3 GBaud 675G
OTN Transcoded
89P3GBAUD_675G_E 89.3 GBaud 675G
Ethernet Transcoded
89P3GBAUD_725G_O 89.3 GBaud 725G
OTN Transcoded
89P3GBAUD_725G_E 89.3 GBaud 725G
Ethernet Transcoded
89P3GBAUD_775G_O 89.3 GBaud 775G
OTN Transcoded
89P3GBAUD_775G_E 89.3 GBaud 775G
Ethernet Transcoded
69P5GBAUD_225G_O 69.5 GBaud 225G
OTN Transcoded
69P5GBAUD_225G_E 69.5 GBaud 225G
Ethernet Transcoded
69P5GBAUD_275G_O 69.5 GBaud 275G
OTN Transcoded
69P5GBAUD_275G_E 69.5 GBaud 275G
Ethernet Transcoded
69P5GBAUD_325G_O 69.5 GBaud 325G
OTN Transcoded
69P5GBAUD_325G_E 69.5 GBaud 325G
Ethernet Transcoded
69P5GBAUD_375G_O 69.5 GBaud 375G
OTN Transcoded
69P5GBAUD_375G_E 69.5 GBaud 375G
Ethernet Transcoded
69P5GBAUD_425G_O 69.5 GBaud 425G
OTN Transcoded
69P5GBAUD_425G_E 69.5 GBaud 425G
Ethernet Transcoded
69P5GBAUD_475G_O 69.5 GBaud 475G
OTN Transcoded
69P5GBAUD_475G_E 69.5 GBaud 475G
Ethernet Transcoded
69P5GBAUD_525G_O 69.5 GBaud 525G
OTN Transcoded
69P5GBAUD_525G_E 69.5 GBaud 525G
Ethernet Transcoded
69P5GBAUD_575G_O 69.5 GBaud 575G
OTN Transcoded
69P5GBAUD_575G_E 69.5 GBaud 575G
Ethernet Transcoded
69P5GBAUD_625G_O 69.5 GBaud 625G
OTN Transcoded
69P5GBAUD_625G_E 69.5 GBaud 625G
Ethernet Transcoded
69P5GBAUD_650G_O 69.5 GBaud 650G
OTN Transcoded
69P5GBAUD_650G_E 69.5 GBaud 650G
Ethernet Transcoded
69P5GBAUD_675G_O 69.5 GBaud 675G
OTN Transcoded
69P5GBAUD_675G_E 69.5 GBaud 675G
Ethernet Transcoded
69P5GBAUD_700G_O 69.5 GBaud 700G
OTN Transcoded
69P5GBAUD_700G_E 69.5 GBaud 700G
Ethernet Transcoded
69P5GBAUD_725G_O 69.5 GBaud 725G
OTN Transcoded
69P5GBAUD_725G_E 69.5 GBaud 725G
Ethernet Transcoded
69P5GBAUD_750G_O 69.5 GBaud 750G
OTN Transcoded
69P5GBAUD_750G_E 69.5 GBaud 750G
Ethernet Transcoded
69P5GBAUD_775G_O 69.5 GBaud 775G
OTN Transcoded
69P5GBAUD_775G_E 69.5 GBaud 775G
Ethernet Transcoded
69P5GBAUD_800G_O 69.5 GBaud 800G
OTN Transcoded
69P5GBAUD_800G_E 69.5 GBaud 800G
Ethernet Transcoded
104P2GBAUD_200G_O 104.2 GBaud 200G
OTN Transcoded
104P2GBAUD_200G_E 104.2 GBaud 200G
Ethernet Transcoded
104P2GBAUD_225G_O 104.2 GBaud 225G
OTN Transcoded
104P2GBAUD_225G_E 104.2 GBaud 225G
Ethernet Transcoded
104P2GBAUD_250G_O 104.2 GBaud 250G
OTN Transcoded
104P2GBAUD_250G_E 104.2 GBaud 250G
Ethernet Transcoded
104P2GBAUD_275G_O 104.2 GBaud 275G
OTN Transcoded
104P2GBAUD_275G_E 104.2 GBaud 275G
Ethernet Transcoded
104P2GBAUD_300G_O 104.2 GBaud 300G
OTN Transcoded
104P2GBAUD_300G_E 104.2 GBaud 300G
Ethernet Transcoded
104P2GBAUD_325G_O 104.2 GBaud 325G
OTN Transcoded
104P2GBAUD_325G_E 104.2 GBaud 325G
Ethernet Transcoded
104P2GBAUD_350G_O 104.2 GBaud 350G
OTN Transcoded
104P2GBAUD_350G_E 104.2 GBaud 350G
Ethernet Transcoded
104P2GBAUD_375G_O 104.2 GBaud 375G
OTN Transcoded
104P2GBAUD_375G_E 104.2 GBaud 375G
Ethernet Transcoded
104P2GBAUD_400G_O 104.2 GBaud 400G
OTN Transcoded
104P2GBAUD_400G_E 104.2 GBaud 400G
Ethernet Transcoded
104P2GBAUD_425G_O 104.2 GBaud 425G
OTN Transcoded
104P2GBAUD_425G_E 104.2 GBaud 425G
Ethernet Transcoded
104P2GBAUD_450G_O 104.2 GBaud 450G
OTN Transcoded
104P2GBAUD_450G_E 104.2 GBaud 450G
Ethernet Transcoded
104P2GBAUD_475G_O 104.2 GBaud 475G
OTN Transcoded
104P2GBAUD_475G_E 104.2 GBaud 475G
Ethernet Transcoded
104P2GBAUD_500G_O 104.2 GBaud 500G
OTN Transcoded
104P2GBAUD_500G_E 104.2 GBaud 500G
Ethernet Transcoded
104P2GBAUD_525G_O 104.2 GBaud 525G
OTN Transcoded
104P2GBAUD_525G_E 104.2 GBaud 525G
Ethernet Transcoded
104P2GBAUD_550G_O 104.2 GBaud 550G
OTN Transcoded
104P2GBAUD_550G_E 104.2 GBaud 550G
Ethernet Transcoded
104P2GBAUD_575G_O 104.2 GBaud 575G
OTN Transcoded
104P2GBAUD_575G_E 104.2 GBaud 575G
Ethernet Transcoded
104P2GBAUD_600G_O 104.2 GBaud 600G
OTN Transcoded
104P2GBAUD_600G_E 104.2 GBaud 600G
Ethernet Transcoded
104P2GBAUD_625G_O 104.2 GBaud 625G
OTN Transcoded
104P2GBAUD_625G_E 104.2 GBaud 625G
Ethernet Transcoded
104P2GBAUD_650G_O 104.2 GBaud 650G
OTN Transcoded
104P2GBAUD_650G_E 104.2 GBaud 650G
Ethernet Transcoded
104P2GBAUD_675G_O 104.2 GBaud 675G
OTN Transcoded
104P2GBAUD_675G_E 104.2 GBaud 675G
Ethernet Transcoded
104P2GBAUD_700G_O 104.2 GBaud 700G
OTN Transcoded
104P2GBAUD_700G_E 104.2 GBaud 700G
Ethernet Transcoded
104P2GBAUD_725G_O 104.2 GBaud 725G
OTN Transcoded
104P2GBAUD_725G_E 104.2 GBaud 725G
Ethernet Transcoded
104P2GBAUD_750G_O 104.2 GBaud 750G
OTN Transcoded
104P2GBAUD_750G_E 104.2 GBaud 750G
Ethernet Transcoded
104P2GBAUD_775G_O 104.2 GBaud 775G
OTN Transcoded
104P2GBAUD_775G_E 104.2 GBaud 775G
Ethernet Transcoded
104P2GBAUD_800G_O 104.2 GBaud 800G
OTN Transcoded
104P2GBAUD_800G_E 104.2 GBaud 800G
Ethernet Transcoded
tuning-mode NORMAL Normal Tuning Mode
ACCELERATED Accelerated Tuning
Mode
FAST Fast Tuning Mode
UNKNOWN Unknown
UNAVAILABLE
tx-chrip AUTO Automatic
POSITIVE Positive
NEGATIVE Negative
tx-disp-prov string Transmitter Dispersion Dispersion ranges
Value and|or defaults are
card specific for
TXMODE
Manual|Automatic|Cus
tom1|OffsetAuto|Exten
dedManual and 0
when it's OFF
tx-freq-prov string Provisioned TX Frequency ranges are
Frequency in THz card and pluggable
(xxx.xxxx) specific.
tx-gid INT Tx Group ID
(0-31 Default=0)
tx-mode MANUAL Manual
Precompensation
Mode
AUTOMATIC Automatic
Precompensation
Mode
CUSTOM1 Custom1
Precompensation
Mode
OFF No Precompensation
Mode
OFFSETAUTO Offset Automatic
Precompensation
Mode
EXTENDEDMANUAL Extended Manual
Precompensation
Mode
FIXEDTX FixedTx
Precompensation
Mode
EXPERT Expert
Precompensation
Mode
UNKNOWN UNKNOWN
Precompensation
Mode
SEARCH Search
Precompensation
Mode
UNAVAILABLE
tx-path-id INT TX path identifier Range from 1..254
(1-254)
tx-phy-map string Tx Physical Mapping
Bitmap
tx-pid INT Tx Physical Layer ID
(0-7 Default=0)
tx-pwr string Provisioned TX Power Power ranges are card
in dBm (xx.x) specific
tx-spctrl-occp NONE NONE
NARROW NARROW
WIDE20 WIDE20
WIDE25 WIDE25
WIDE30 WIDE30
WIDE40 WIDE40
WIDE50 WIDE50
MINSPACE20 MINSPACE20
MINSPACE25 MINSPACE25
tx-wvlngth-prov string Provisioned Range: 1528.77 -
Wavelength 1565.09 @ 50Ghz
spacing. The
wavelength will be of
the format xxxx.xx and
nm will be assumed.
tx-wvlngth-spacing 0 0 GHz
50 50 GHz
100 100 GHz
200 200 GHz
FLEXGRID FLEXGRID
UNKNOWN UNKNOWN
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
MT Maintenance
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
PTP (6500-T12) PTP-shelf-slot-ALL PTP-[0..992]-[1..12]-ALL
PTP (6500-T24) PTP-shelf-slot-ALL PTP-[0..992]-[1..24]-ALL
PTP PTP-shelf-ALL PTP-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
disp-scan-info YES Include SFROM, STO,
SSTEP, SDWELL,
SCAN,
OCHTXDISPFOUND
and OCHASSOCQ in
the output
NO Do not include
SFROM,STO, SSTEP,
SDWELL, SCAN,
OCHTXDISPFOUND
and OCHASSOCQ in
the output
stats-info NO Do not include
Dynamic Status
information in the
response
YES Include Dynamic
Status information in
the response
Syntax Definition
Parameter Attributes Description Notes
ptp M aid
act_trans-mode O Actual Transmission
Mode
act-carrier-centering- O Actual Applied Laser
mode centering mode
act-ccda O Actual Applied
Channel Contention
Detection and
Avoidance
act-exp-res-time O Actual Applied
Acquisition Holdoff
Time
act-laser-centering- O Actual Applied laser Laser centering range
range centering range in GHz
act-linkOpt-mode O Actual Applied Link
Optimization Mode
act-och-tx-blanking O Actual Applied TX
power in reduced
state.
act-path-disp O Actual Applied Path
Dispersion Value
act-tuning-mode O Activated Tuning Mode
act-tx-disp O Actual Applied
Transmitter Dispersion
Value
act-tx-freq O Actual Applied TX Frequency ranges are
Frequency in THz card and pluggable
(xxx.xxxx) specific.
act-tx-mode O Actual Applied
Transmitter Dispersion
Mode
act-tx-wvlngth O Actual Applied Range: 1528.77 -
Wavelength 1565.09 @ 50Ghz
spacing. The
wavelength will be of
the format xxxx.xx and
nm will be assumed.
ains-time-left O The format will be "HH-
MM" for the time left in
AINS timeout.
allocated-spec-width O Allocated Spectral
Width
assoc-q O Q associated with the
found optimum
precomp
baud O OTSi Baud rate (35G
or 56G)
bit-rate O PTP Bit Rate PTP bit rate in
OTUCn-M
configuration.
carrier-centering-mode O Laser centering mode
ccda O TX Channel
Contention Detection
and Avoidance
cond-type O The type of Tx Its default value is
conditioning to do in specified by
response to certain LASEROFFFARENDF
faults AIL attribute of ED-
SYS.
differential-encoding O OCH Differential
Encoding
enm-prov O OCH ENM used for enhancing
provisioning mode non-linear mitigation
est-length O Estimated fiber length Displayed in xxxx
meters.
exp-res-time-prov O Provisioned
Acquisition Holdoff
Time
fec-frmt O Tx/Rx FEC Format
frr O OCH Fast Receiver
Recovery
frr-config O OCH FRR Network
Configuration
frr-path1-disp O OCH FRR Link Range = -80000 to
Dispersion for Path 1 +80000 for 100G WL3
OCLD and 100G WL3i
PKTOTN, -50000 to
+50000 for 40G
OCLD, Units in ps/nm
frr-path2-disp O OCH FRR Link Range = -80000 to
Dispersion for Path 2 +80000 for 100G WL3
OCLD and 100G WL3i
PKTOTN, -50000 to
+50000 for 40G
OCLD, Units in ps/nm
label O User specified Label
laser-bias-end-of-life O Laser Bias Current. Displayed in
milliAmps.
laser-centering-range O Provisioned laser Laser centering range
centering range in GHz
laser-freq-thr O Laser Frequency The target will be of
Threshold the format +/- x.x and
GHz will be assumed.
laser-off-mode O Laser Off Mode
laser-status O Laser status
laser-tuned O Laser tuning status
line-fail O Line Fail
line-type O OCH Line Sys Type
linkOpt-mode O Link Optimization
Mode
lnkCustom1 O Link Custom1
lnkCustom2 O Link Custom2
lqs-managed O Liquid Spectrum
managed
m-aid O L Specify the Member
PTP AID List. Format:
Member2&Member3&.
..
mod O Modulation scheme PTP Modulation
scheme in OTUk
configuration.
modem-class O Modem Class
och-max-pmd O Supported Mean DGD Displayed in xx ps.
(Differential Group
Delay) value
och-rx-act-disp O Receiver total actual
link dispersion in the
far-to-near direction
och-rx-act-high-power O RX active high power Power ranges are card
in dBm (xx.x) specific
och-rx-act-low-power O RX active low power in Power ranges are card
dBm (xx.x) specific
och-rx-act-pmd O Estimated Instance of Displayed in xx ps.
DGD (Differential
Group Delay) value
och-rx-act-power O RX actual power in Power ranges are card
dBm (xx.x) specific
och-rx-ch-act-power O RX channel actual Power ranges are card
power in dBm (xx.x) specific
och-rx-ch-max-power O RX channel maximum Power ranges are card
power in dBm (xx.x) specific
och-rx-ch-min-power O RX channel minimum Power ranges are card
power in dBm (xx.x) specific
och-rx-echo-trace O TR Transmit Identifier
Received
och-rx-max-power O RX maximum power in Power ranges are card
dBm (xx.x) specific
och-rx-min-power O RX minimum power in Power ranges are card
dBm (xx.x) specific
och-rx-post-disp O Rx Postcompensation Status value received
Dispersion Value. from HW
och-tx-act-disp O Transmitter total actual
link dispersion in the
near-to-far direction
och-tx-act-high-power O TX active high power Power ranges are card
in dBm (xx.x) specific
och-tx-act-low-power O TX active low power in Power ranges are card
dBm (xx.x) specific
och-tx-act-power O TX actual power in Power ranges are card
dBm (xx.x) specific
och-tx-assoc-far-end-rx O Transmitter associated
far end receiver
och-tx-blanking O Manually force the
Line port TX power in
reduced state.
och-tx-freqr-es O Supported frequency Frequency resolution
resolution in GHz
och-tx-max-power O TX maximum power in Power ranges are card
dBm (xx.x) specific
och-tx-min-power O TX minimum power in Power ranges are card
dBm (xx.x) specific
och-tx-min-spec-width O Minimum spectral BW spectral width in
width GHz
och-tx-pre-disp O Tx Precompensation
Dispersion Value.
och-tx-sig-bw-10db O Supported 10dB Unknown if EQPT
bandwidth value missing
och-tx-sig-bw-3db O Supported 3dB Unknown if EQPT
bandwidth value missing
och-tx-trace O TR Transmit Identifier
Received Expected
optimize-mode O Performance
Optimization Mode
p-aid O Specify the Prime PTP Not valid when PTP
AID. Role is Prime, it's
mandatory when PTP
Role is Member
path-disp-prov O Path Dispersion Value
pre-fec-sd-th-ber O The corresponding
BER for a given Pre-
FEC SD Threshold
setting in dDQ
pre-fec-sd-th-lev O Pre-FEC Signal The target will be of
Degrade Threshold the format +/- x.x and
dBQ will be assumed.
pre-fec-sf-th-ber O The corresponding
BER for a given Pre-
FEC SF Threshold
setting in dDQ
pre-fec-sf-th-lev O Pre-FEC Signal Fail The target will be of
Threshold the format +/- x.x and
dBQ will be assumed.
pwr-bal-act-offset O Provisioned Power Power Balance ranges
Balance Actual Offset are card specific
in dB (xx.x)
pwr-bal-ctlr O Provisioned Power
Balance Controller
Operating Mode
pwr-bal-offset O Provisioned Power Power Balance ranges
Balance Offset in dB are card specific
(xx.x)
reach-class O Reach Class
reach-spec O Reach Specification Displayed in xxxx km.
reach-type O Reach Type
role O Role type in OTUCn-M This parameter
configuration indicate the PTP is
Prime or Member.
rotation O Jones Rotation Setting
rqst-allocated-spec- O Requested Allocated
width Spectral Width
rqst-carrier-centering- O Requested Laser
mode centering mode
rqst-ccda O Requested Channel
Contention Detection
and Avoidance
rqst-exp-res-time O Requested Acquisition
Holdoff Time
rqst-laser-centering- O Requested laser Laser centering range
range centering range in GHz
rqst-line-type O Requested Line Sys
Type
rqst-linkOpt-mode O Requested Link
Optimization Mode
rqst-lqs-managed O Requested Liquid
Spectrum managed
rqst-och-tx-blanking O Requested TX power
in reduced state.
rqst-path-disp O Requested Path
Dispersion Value
rqst-trans-mode O Requested
Transmission Mode
rqst-tuning-mode O Requested Tuning
Mode
rqst-tx-disp O Requested Transmitter
Dispersion Value
rqst-tx-freq O Requested TX Frequency ranges are
Frequency in THz card and pluggable
(xxx.xxxx) specific.
rqst-tx-mode O Requested Transmitter
Dispersion Mode
rqst-tx-pwr O Requested TX Power Power ranges are card
in dBm (xx.x) specific
rqst-tx-wvlngth O Requested Range: 1528.77 -
Wavelength 1565.09 @ 50Ghz
spacing. The
wavelength will be of
the format xxxx.xx and
nm will be assumed.
rqst-tx-wvlngth-spacing O Requested 50 Ghz by default
Wavelength Spacing,
in nm
rtd O OCH Round Trip Displayed in the form
Delay. of xxxx.xx us.
rx-act-ln-pwr O L Lane RX Power in Lane number are
dBm (xx.x) (Format: pluggable specific
Lane1|Lane2|...)
rx-ch-pwr-h-thr O Provisioned Rx Range from 1.0 to 10.0
channel Power OOR
high threshold
rx-ch-pwr-l-thr O Provisioned Rx Range from -30.0 to
channel Power OOR -1.0
low threshold
rx-fec-frmt O Type of Forward Error
Correction on RX
rx-gid O Rx Group ID
rx-phy-map O Rx Physical Mapping
Bitmap
rx-pid O Rx Physical Layer ID
rx-pwr-h-thr O Provisioned Rx Power Range from 1.0 to 10.0
OOR high threshold
rx-pwr-l-thr O Provisioned Rx Power Range from -30.0 to
OOR low threshold -1.0
rx-pwr-thr-prov O Enable to use
provisioned thresholds
saved-linkOpt-mode O Saved Actual Applied
Link Optimization
Mode
saved-trans-mode O Saved Actual Applied
Transmission Mode
scan O Q-based Pre- Q-based
dispersion Precompensation
compensation Scanning
Scanning
s-dwell O Scanning dwell time,
second
ser-path-disp-max-prov O Provisioned Path
Dispersion Maximum
for the SEARCH mode
ser-path-disp-min-prov O Provisioned Path
Dispersion Minimum
for the SEARCH mode
service-type O Configured Service This parameter will
Type specify the TTP
created as a child of
this PTP.
s-from O FROM point of
scanning range, ps/nm
spli-managed O Identify if Port is
Currently Managed by
SPLI
spli-mgmt O Identify if Port is
Manageable by SPLI
s-step O Compensation
optimization scanning
step size , ps/nm
s-to O TO point of scanning
range, ps/nm
trans-mode O Transmission Mode
ttops O Transponder Triggered Transponder Triggered
Switching Mode Protection
Enabled
tuning-mode O Provisioned Tuning
Mode
tx-act-ln-pwr O L Lane TX Power in dBm Lane number are
(xx.x) (Format: pluggable specific
Lane1|Lane2|...)
tx-chrip O Positive or Negative Used for TXR in 100G
Chirp setting
tx-disp-found O Found the optimum
Pre-dispersion
compensation from the
scanning, ps/nm
tx-disp-max O Maximum Transmitter
Dispersion Value
tx-disp-min O Minimum Transmitter
Dispersion Value
tx-disp-prov O Transmitter Dispersion
Provisioned Value
tx-fec-frmt O Type of Forward Error
Correction on TX
tx-freq-max O Maximum TX Frequency ranges are
Frequency value in card and pluggable
THz (xxx.xxxx) specific.
tx-freq-min O Minimum TX Frequency ranges are
Frequency value in card and pluggable
THz (xxx.xxxx) specific.
tx-freq-prov O Provisioned TX Frequency ranges are
Frequency in THz card and pluggable
(xxx.xxxx) specific.
tx-gid O Tx Group ID
tx-mode O Transmitter Dispersion
Mode
tx-path-id O TX path identifier Range from 1..254
tx-phy-map O Tx Physical Mapping
Bitmap
tx-pid O Tx Physical Layer ID
tx-pwr O Provisioned TX Power Power ranges are card
in dBm (xx.x) specific
tx-spctrl-occp O OCH Spectral
Occupancy setting
tx-wvlngth-max O Maximum Wavelength 1568.77 nm. The
Range wavelength will be of
the format xxxx.xx and
nm will be assumed.
tx-wvlngth-min O Minimum Wavelength 1528.38 nm. The
Range wavelength will be of
the format xxxx.xx and
nm will be assumed.
tx-wvlngth-prov O Provisioned Range: 1528.77 -
Wavelength 1565.09 @ 50Ghz
spacing. The
wavelength will be of
the format xxxx.xx and
nm will be assumed.
tx-wvlngth-spacing O OCH Wavelength 50 Ghz by default
Spacing, in nm
uni-latency O OCH Unidirectional Displayed in the form
Latency. of xxxx.xx us.
pst M Identify the primary
State
sst O L Secondary State
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport
Input Parameter Description
Parameter Value Description Notes
sst MT Maintenance
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
Input Parameter Description
Parameter Value Description Notes
scan START Triggers Q-based pre-
dispersion
compensation
scanning
STOP Cancels Q-based Pre-
dispersion
compensation
Scanning
COMPLETE Indicates completion of
Scanning, only for
retrieval
s-dwell string Scanning dwell time,
second
s-from string FROM point of
scanning range, ps/nm
s-step string Compensation
optimization scanning
step size , ps/nm
s-to string TO point of scanning
range, ps/nm
AID Descriptions
AID Type Format Values
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port
Input Parameter Description
Parameter Value Description Notes
dapi-chg-evt ON Enable OTU DAPI
Specific TTI Change
event
OFF Disable OTU DAPI
Specific TTI Change
event
degm-intv INT Consecutive bad Range of DEGMINTV
(2-10) intervals required to is 2 to 10
declare signal degrade
degthr-percentage INT Percentage of errored Range of
(1-1000) blocks required to DEGTHRPERC is
declare an interval bad 1=1x10E-2, 2=2x10E-
2 ... 1000=1000x10E-2
ex-dapi string The expected
( min len=0 max len=15 ) Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper string The expected operator 32 byte printable
( min len=0 max len=32 ) specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-sapi string The expected Source 15 byte printable
( min len=0 max len=15 ) Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
hold-off INT HoldOff signal
(0,10,20...1000) conditioning timer
hold-on INT HoldOn signal
(0,2,4...500) conditioning timer
label string User specified Label
( min len=0 max len=64 )
num-ts INT Used to identify the
(1-160) number of tributaries
comprising this TTP.
For on OTN TTP, this
can change based on
potential configuration
of desired payload
type (e.g. for ODU1
with OPVC payload,
this value is 16; with
CBR it is 1).
oper-chg-evt ON Enable OTU Operator
Specific TTI Change
event
OFF Disable OTU Operator
Specific TTI Change
event
otu-oh-non-term NONE Entire GCC OH
terminated
GCC0 GCC0 portion of OTU
OH not terminated
otu-sd-th-lev INT OTU Signal Degrade Range of
(6-9 Default=6) Threshold Level OTUSDTHLEV is
6=10E-6, 9=10E-9.
rate OTU1
OTU1E
OTU2
OTU2E
OTU3
OTU3E2
OTU4
OTUC2-40
OTUC2-30
OTUC4-80
OTUC4-60
OTU2REGEN
OTU2EREGEN
OTUC1
OTUC2
OTUC3
OTUC4
OTUC5
OTUC6
OTUC7
OTUC8
rout-sig-disabled NO Routing signalling
enabled. The OSRP
will have control over
the ODUs created
under this TTP and no
user created ODU will
be allowed.
YES Routing signalling
disabled
sapi-chg-evt ON Enable OTU SAPI
Specific TTI Change
event
OFF Disable OTU SAPI
Specific TTI Change
event
tf-mode OFF Alarms off, no traffic
protection
ALMONLY Alarms on, no traffic
protection
LINEFAIL Alarms on, with traffic
protection
tim-enable TIM_SAPI_ONLY Only checks for SAPI
mismatch
TIM_DAPI_ONLY Only checks for DAPI
mismatch
TIM_SAPI_DAPI Checks for SAPI and
DAPI mismatch
TIM_OPER_SPEC Checks for Operator
Specific mismatch
tx-dapi string The Destination
( min len=0 max len=15 ) Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper string The operator specific 32 byte printable
( min len=0 max len=32 ) part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi string The Source Access 15 byte printable
( min len=0 max len=15 ) Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
MT Maintenance
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTU (6500-T12) OTUTTP-shelf-slot-ALL OTUTTP-[0..992]-[1..12]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-ALL OTUTTP-[0..992]-[1..24]-ALL
OTU OTUTTP-shelf-ALL OTUTTP-[0..992]-ALL
ALL objects ALL ALL
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port
Input Parameter Description
Parameter Value Description Notes
stats-info NO Do not include
Dynamic Status
information in the
response
YES Include Dynamic
Status information in
the response
Syntax Definition
Parameter Attributes Description Notes
otu M aid
act-num-ts O
ains-time-left O The format will be HH-
MM for the time left in
AINS timeout.
dapi-chg-evt O To enable or disable
OTU DAPI Specific TTI
Change events
ex-dapi O The expected
Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper O The expected operator 32 byte printable
specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-sapi O The expected Source 15 byte printable
Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
hold-off O HoldOff signal
conditioning timer
hold-on O HoldOn signal
conditioning timer
label O User specified Label
local-sup-cacline-id O The generic cacline Supported for OTN
end point representing only
this facility shown in
54xx nomenclature
(<bay>-<A|C>-<slot>-
<port>)
num-ts O Used to identify the
number of tributaries
comprising this TTP.
For on OTN TTP, this
can change based on
potential configuration
of desired payload
type (e.g. for ODU1
with OPVC payload,
this value is 16; with
CBR it is 1).
oper-chg-evt O To enable or disable
OTU Operator Specific
TTI Change events
osrp-channel O The OSRP channel
osrp-tcm-level O This attribute specifies
the TCM level for the
OSRP created ODUs
under this OTUTTP.
The value of 0
indicates that no TCM
will be created. The
default value is
specified by the
attribute
OSRPTCMLEVEL in
the command ED-
SYS.
otu-act-rate O Actual OTUCn rate,
OTUCn(n=1..8)
otu-sd-th-lev O OTU Signal Degrade Range of
Threshold Level OTUSDTHLEV is
6=10E-6, 9=10E-9
otu-sf-th-lev O OTU Signal Fail Range of
Threshold Level OTUSFTHLEV is
6=10E-6, 9=10E-9
pre-fec-sd-th-ber O Pre-FEC Signal Range (all FECs) =
Degrade Threshold Bit 0.00 to 1.00
Error Rate. Parameter
applies when FEC is
ON
pre-fec-sd-th-lev O Pre-FEC Signal Range = 0.00 dBQ to
Degrade Threshold 3.50 dBQ for SCFEC
Level. Parameter and PFEC, and 0.00
applies when FEC is dBQ to 2.0 dBQ for
ON RS8 FEC,
provisionable in 0.01
increments.
pre-fec-sf-th-ber O Pre-FEC Signal Fail Range (all FECs) =
Threshold Bit Error 0.00 to 1.00
Rate. Parameter
applies when FEC is
ON
pre-fec-sf-th-lev O Pre-FEC Signal Fail Range (all FECs) =
Threshold Level. -1.00 dBQ to 1.00
Parameter applies dBQ, default=0.00
when FEC is ON
rate M OTUCn Rate
rout-sig-disabled O Specifies whether
Routing Signalling is
disabled on this TTP.
When to NO, the
OSRP will have control
over the ODUs created
under this TTP and no
user created ODU will
be allowed.
rx-dapi O The Destination
Access Point Identifier
(DAPI) recovered from
the Trail Trace
Identifier (TTI)
overhead position at
the sink of a trail.
rx-fec-frmt O Type of Forward Error
Correction on RX
rx-oper O The operator specific
part of the Trail Trace
Identifier (TTI)
information, recovered
from the TTI overhead
position at the sink of a
trail.
rx-sapi O The Source Access
Point Identifier (SAPI)
recovered from the
Trail Trace Identifier
(TTI) overhead
position at the sink of a
trail.
sapi-chg-evt O To enable or disable
OTU SAPI Specific TTI
Change events
supported-term-pt O The supporting Possible AID: PTP-
Termination Point. shelf-slot-port.
tf-mode O Trace Fail Mode
tim-enable O The Trail Trace
Identifier Mismatch
(TIM) controls
checking for Trace
Identifier Mismatch
fault detection.
timing-reference O Indicates whether the
facility is being used as
a timing reference
ts-profile O TS Profile
tx-dapi O The Destination
Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-fec-frmt O Type of Forward Error
Correction on TX
tx-oper O The operator specific 32 byte printable
part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi O The Source Access 15 byte printable
Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
pst M Identify the primary
State
sst O L Secondary State
AID Descriptions
AID Type Format Values
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port
Input Parameter Description
Parameter Value Description Notes
sst MT Maintenance
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
Input Parameter Description
Parameter Value Description Notes
loopback-type FACILITY Signal looped toward
the equipment
TERMINAL Signal looped away
from the equipment
AID Descriptions
AID Type Format Values
STTP (6500-T12) STTP-shelf-slot-port STTP-[0..992]-[1..12]-[1..40]
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
WL AI STTP (6500 2-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..2]-[2..44]
WL AI STTP (6500 7-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..7]-[2..44]
WL AI STTP (6500 7 PKT- STTP-shelf-slot-port STTP-[0..992]-[1..6]-[2..44]
OPT)
WL AI STTP (6500 14-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..6,9..14]-[2..44]
WL AI STTP (6500 32-Slot) STTP-shelf-slot-port STTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
STTP (6500-T12) STTP-shelf-slot-portSsubport STTP-[0..992]-[1..12]-[1..40]S[1..4]
STTP (6500-T24) STTP-shelf-slot-portSsubport STTP-[0..992]-[1..24]-[1..40]S[1..4]
Input Parameter Description
Parameter Value Description Notes
sst MT Maintenance
AID Descriptions
AID Type Format Values
STTP (6500-T12) STTP-shelf-slot-port STTP-[0..992]-[1..12]-[1..40]
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
STTP (6500-T12) STTP-shelf-slot-portSsubport STTP-[0..992]-[1..12]-[1..40]S[1..4]
STTP (6500-T24) STTP-shelf-slot-portSsubport STTP-[0..992]-[1..24]-[1..40]S[1..4]
STTP (6500-T12) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
STTP (6500-T12) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..12]S[1..3]-[1..12]
STTP (6500-T24) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
STTP (6500-T24) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..24]S[1..3]-[1..12]
Input Parameter Description
Parameter Value Description Notes
loopback-type FACILITY Signal looped toward
the equipment
TERMINAL Signal looped away
from the equipment
AID Descriptions
AID Type Format Values
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT)
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
Input Parameter Description
Parameter Value Description Notes
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
MT Maintenance
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
Input Parameter Description
Parameter Value Description Notes
cond-type 8B10B
K30_7
LF_RF
ETH_IDLE
LNKFLTC1C2
NONE
fec-frmt OFF NO FEC
RS10 RS10 FEC
RS10_KP4 RS10_KP4 FEC
flow-ctrl NONE, ASYM, PREE, SYM Flow control
mechanism.
force NO Do Not Force Edit
YES Force Traffic Impacting Force edit could
Edit impact the traffic. Only
use FORCE=YES
when you understand
the impact.
hold-off INT Conditioning holdoff
(0,10,20...1000 Default=100) time in seconds.
if-type UNI, E-NNI, I-NNI Interface Type
label string User specified Label
( min len=0 max len=64 )
mapping NONE No mapping
GFPSTD GFP Standard/MAC
transparent
GFPMACTR GFP Preamble/MAC
transparent
GFPMACOSTR GFP
Preamble/Ordered
Set/MAC transparent
PROP237 Fully transparent
GMP Generic Mapping
Procedure.
BMP Bit-synchronous
Mapping Procedure
IMP Idle Mapping
Procedure
max-transmit-unit 1600, 9600, 2000 Maximum
Transmission Unit
(actually MRU)
pre-fec-sd-th-ber string Pre-FEC Signal
Degrade Threshold Bit
Error Rate.
pre-fec-sd-th-lev string Pre-FEC Signal Range = -1.00 dBQ to
Degrade Threshold 2.00 dBQ, default =
Level. 0.50 dBQ
pre-fec-sf-th-ber string Pre-FEC Signal Fail
Threshold Bit Error
Rate.
pre-fec-sf-th-lev string Pre-FEC Signal Fail Range = -1.00 dBQ to
Threshold Level. 1.00 dBQ, default =
0.00 dBQ
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
Input Parameter Description
Parameter Value Description Notes
loopback-type FACILITY Signal looped toward
the equipment
TERMINAL Signal looped away
from the equipment
AID Descriptions
AID Type Format Values
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [2,2E,3,3E2,4,C2,C4,CN]P[1]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]-
[0,1,2,2E,3,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [2,2E,3,3E2,4,C2,C4,CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]-
[0,1,2,2E,3,F]P[1..80]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [CN]P[1]
ODUTTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..12]-
rt1Ptp1 [CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..12]-
rt1Ptp1 [CN]P[1]
AID Descriptions
AID Type Format Values
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU TTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-ALL [2,2E,3,4,C2,C4,CN]P[1]-ALL
ODU TTP (6500-T12) ODUTTP-shelf-slot-port-ALL ODUTTP-[0..992]-[1..12]-[1..40]-ALL
ODU TTP (6500-T12) ODUTTP-shelf-slot-ALL ODUTTP-[0..992]-[1..12]-ALL
ODU TTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-ALL [2,2E,3,4,C2,C4,CN]P[1]-ALL
ODU TTP (6500-T24) ODUTTP-shelf-slot-port-ALL ODUTTP-[0..992]-[1..24]-[1..40]-ALL
ODU TTP (6500-T24) ODUTTP-shelf-slot-ALL ODUTTP-[0..992]-[1..24]-ALL
ODU TTP ODUTTP-shelf-ALL ODUTTP-[0..992]-ALL
ODU TTP (6500-T12) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODU TTP (6500-T24) ODUTTP-shelf-slot- ODUTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [CN]P[1]
ODUTTP (6500-T12) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..12]-[1..12]-
rt1Ptp1 [CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slot-port- ODUTTP-[0..992]-[1..24]-[1..12]-
rt1Ptp1 [CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [2,2E,3,3E2,4,C2,C4,CN]P[1]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]
ODUTTP (6500-T12) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]-
[0,1,2,2E,3,F]P[1..80]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,C2,C4,CN]P[1]
ODU TTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [2,2E,3,3E2,4,C2,C4,CN]P[1]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]
ODUTTP (6500-T24) ODUTTP-shelf-slotSsubslot- ODUTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..80]-
[0,1,2,2E,3,F]P[1..80]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
stats-info NO Do not include
Dynamic Status
information in the
response
YES Include Dynamic
Status information in
the response
Syntax Definition
Parameter Attributes Description Notes
oduttp M aid
act-avail-ts O Actual available TS The Default is
supported by the dependent on the
TRANSMODE. Transmission Mode.
anchor-ts O Anchor of tx triburtary The lowest tribSlot
slot when the ODUFLEX
rate is created.
base-ho O Base HO ODUk
bit-rate O Define the bit rate of
flex.
client-type O Server layer client type
cond-type O L Conditioning behaviour
on client faults.
dm-count O Value of delay
measurement of ODU
in micro seconds.
dm-enable O Specify if delay
measurement is
enable.
ex-dapi O The expected
Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper O The expected operator32 byte printable
specific part of the ASCII character string.
This parameter
Trail Trace Identifier
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
0x20 to 0x7E.- spaces
the termination source,
(supported in strings).-
to be placed in the TTI
overhead position of Double quotation
marks (must have a
the source of a trail.
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-pt O The expected payload 2 hexa decimal digits
type.
ex-rx-ts O Expected Receive This is represented by
tributary slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
ex-sapi O The expected Source 15 byte printable
Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
flex-type O ODU flex type
label O User specified Label
line-prot-group O Line Protection Group
in AID format
line-prot-role O Line Protection Role
line-prot-type O Line Protection Type
local-sup-cacline-id O The generic cacline Supported for OTN
end point representing only
this facility shown in
54xx nomenclature
(<bay>-<A|C>-<slot>-
<port>)
num-ts O Used to identify the
number of tributaries
comprising this TTP.
For on OTN TTP, this
can change based on
potential configuration
of desired payload
type (e.g. for ODU1
with OPVC payload,
this value is 16; with
CBR it is 1).
odu1-interop O Required Interop
Equipment Type
owner O Specifies who created
this TTP.
prov-msi O Provisioned MSI for all This is represented by
tributary slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
rate O Rate
reserved O Specify if the facility is
being reserved for
packet SNC's
resizeable O ODUFlex is resizeable
rx-dapi O The Destination
Access Point Identifier
(DAPI) recovered from
the Trail Trace
Identifier (TTI)
overhead position at
the sink of a trail.
rxmon O Indicate if the signal is
monitored in the Rx
direction for alarms
and PMs and OMs.
rx-msi O Actual received MSI This is represented by
for all tributary slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
rx-oper O The operator specific
part of the Trail Trace
Identifier (TTI)
information, recovered
from the TTI overhead
position at the sink of a
trail.
rx-pt O The received payload 2 hexa decimal digits
type.
rx-sapi O The Source Access
Point Identifier (SAPI)
recovered from the
Trail Trace Identifier
(TTI) overhead
position at the sink of a
trail.
rx-ts O Received tributary This is represented by
slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
rx-ts-mode O Receive Tributary Slot
Mode
sd-th O Signal Degrade Range of SDTH is
Threshold Value 5=10E-5, 6=10E-6, ... ,
9= 10E-9.
sf-th O Signal Fail Threshold Range of SFTH is 0
Level. and from 6 to 9
supported-term-pt O The supporting Possible AIDs: FTTP-
Termination Point. shelf-slot-port,
OTUTTP-shelf-slot-
port, ODUTTP-shelf-
slot-port-
rt1Ptp1[rt2Ptp2[-
rt3Ptp3[-rt4Ptp4]]]
tf-mode O Trace Fail Mode
tim-enable O The Trail Trace
Identifier Mismatch
(TIM) controls
checking for Trace
Identifier Mismatch
fault detection.
timing-reference O Indicates whether the
facility is being used as
a timing reference
tolerance O Define the tolerance in
ppm of oduflex
payload.
trib-slot-assignment O The tributary slots This is represented by
used by this ODU. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
trib-slot-prov O tribSlot provision
ts-size O The tributary slot size
tx-dapi O The Destination
Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper O The operator specific 32 byte printable
part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi O The Source Access 15 byte printable
Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
pst M Identify the primary
State
sst O L Secondary State
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
cond-type NONE
OPUK_AIS
OPUK_CSF
ODUK_AIS
ctp-mode TRANSPARENT, MONITOR, The mode of the
TERMINATED ODUCTP.
dm-enable YES
NO
ex-dapi string The expected
( min len=0 max len=15 ) Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper string The expected operator 32 byte printable
( min len=0 max len=32 ) specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-pt string The expected payload 2 hexa decimal digits
( min len=2 max len=2 ) type.
ex-sapi string The expected Source 15 byte printable
( min len=0 max len=15 ) Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
flex-type GFP_F The flex type is GFP_F
CBR The flex type is CBR
IMP The flex type is IMP
gep YES, NO Specifies whether the This parameter is only
end-point facility applicable to OTN.
accepts Generict End
Point (GEP) method.
gep-name string Specifies the Generict This parameter is only
( min len=1 max len=64 ) End Point (GEP) applicable to OTN.
name.
label string User specified Label
( min len=0 max len=64 )
num-ts INT Used to identify the Only applicable to
(1-80) number of tributaries rate=ODUFlex
comprising this CTP.
rx-ts-mode OFF Alarms off,
Conditioning off
ALM_ONLY Alarms on
COND_ONLY Conditioning on
ALM_COND Alarm on, conditioning
on
sd-th INT Signal degrade Range of SDTH is
(6-9) threshold value 6=10E-6, 7=10E-7, ... ,
9= 10E-9.
sf-th INT Signal Fail Threshold Range of SFTH is 0
(0-9) Level. and from 6 to 9
tf-mode OFF Alarms off, no traffic
protection
ALMONLY Alarms on, no traffic
protection
LINEFAIL Alarms on, with traffic
protection
tim-enable TIM_SAPI_ONLY Only checks for SAPI
mismatch
TIM_DAPI_ONLY Only checks for DAPI
mismatch
TIM_SAPI_DAPI Checks for SAPI and
DAPI mismatch
TIM_OPER_SPEC Checks for Operator
Specific mismatch
trib-slot-assignment string The tributary slots This is represented by
( min len=1 max len=51 ) used by this ODU. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
trib-slot-prov AUTO The Rx trib slot is auto-
detected by system.
MANUAL The Rx trib slot is user
specified.
CONT The Rx trib slot is
contiguous.
tx-dapi string The Destination
( min len=0 max len=15 ) Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper string The operator specific 32 byte printable
( min len=0 max len=32 ) part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi string The Source Access 15 byte printable
( min len=0 max len=15 ) Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-ALL [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-ALL [2,4,C2,C4,CN]P[1]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-port-ALL ODUCTP-[0..992]-[1..12]-[1..40]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-ALL ODUCTP-[0..992]-[1..12]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-ALL [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-ALL [2,4,C2,C4,CN]P[1]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port-ALL ODUCTP-[0..992]-[1..24]-[1..40]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-ALL ODUCTP-[0..992]-[1..24]-ALL
ODU CTP ODUCTP-shelf-ALL ODUCTP-[0..992]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
[4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
port-rt1Ptp1-rt2Ptp2-rt3Ptp3
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
stats-info NO Do not include
Dynamic Status
information in the
response
YES Include Dynamic
Status information in
the response
Syntax Definition
Parameter Attributes Description Notes
oductp M aid
base-ho O Base HO ODUk
bit-rate O Define the bit rate of
flex.
client-type O Indicate the type of
client signal
cond-type O L Conditioning behaviour
on client faults.
ctp-mode O The mode of the
ODUCTP.
dm-count O Value of delay
measurement of ODU
in micro seconds.
dm-enable O Specify if delay
measurement is
enable.
ex-dapi O The expected
Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper O The expected operator 32 byte printable
specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-pt O The expected payload 2 hexa decimal digits
type.
ex-rx-ts O Expected receive This is represented by
tributary slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
ex-sapi O The expected Source 15 byte printable
Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
flex-type O ODU flex type
gep O Specifies whether the This parameter is only
end-point facility applicable to OTN.
accepts Generict End
Point (GEP) method.
gep-name O Specifies the Generict This parameter is only
End Point (GEP) name applicable to OTN.
for this facility.
label O User specified Label
num-ts O Used to identify the
number of tributaries
comprising this CTP.
owner O Specifies who created
this CTP.
rate O Rate
resizeable O ODUFlex is resizeable
rx-dapi O The Destination
Access Point Identifier
(DAPI) recovered from
the Trail Trace
Identifier (TTI)
overhead position at
the sink of a trail.
rx-oper O The operator specific
part of the Trail Trace
Identifier (TTI)
information, recovered
from the TTI overhead
position at the sink of a
trail.
rx-pt O The received payload 2 hexa decimal digits
type.
rx-sapi O The Source Access
Point Identifier (SAPI)
recovered from the
Trail Trace Identifier
(TTI) overhead
position at the sink of a
trail.
rx-ts O Received tributary This is represented by
slots. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
rx-ts-mode O Received Tributary
Slot Mode
sd-th O Signal degrade Range of SDTH is
threshold value 6=10E-6, 7=10E-7, ... ,
9= 10E-9
sf-th O Signal Fail Threshold Range of SFTH is 0
Level. and from 6 to 9
supported-term-pt O The supporting Possible AIDs: WAN-
Termination Point. shelf-slot-port, FTTP-
shelf-slot-port, STTP-
shelf-slot-port, ETTP-
shelf-slot-port,
OTUTTP-shelf-slot-
port, ODUTTP-shelf-
slot-port-
rt1Ptp1[rt2Ptp2[-
rt3Ptp3[-rt4Ptp4]]]
tf-mode O Trace Fail Mode
tim-enable O The Trail Trace
Identifier Mismatch
(TIM) controls
checking for Trace
Identifier Mismatch
fault detection.
tolerance O Define the tolerance in
ppm of oduflex
payload.
trib-slot-assignment O The tributary slots This is represented by
used by this ODU. up to 20 hexa decimal
characters separated
by dash every 4 hexa
decimals. The most
significant bit of the
hex values represents
the least significant
tributary slot (tributary
slot 0). The zeros at
the end are optional.
Example: 91C0-0FFF-
FC07-FC00-0000
trib-slot-prov O tribSlot provision
tx-dapi O The Destination
Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper O The operator specific 32 byte printable
part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi O The Source Access 15 byte printable
Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
pst M Identify the primary
State
sst O L Secondary State
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
parent NO immediate ODUTTP
parent facility is not to
be deleted
YES immediate ODUTTP
parent facility is to be
deleted
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
parent NO immediate ODUTTP
parent facility is not to
be removed from
service
YES immediate ODUTTP
parent facility is to be
removed from service
sst MT Maintenance
AID Descriptions
AID Type Format Values
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[1]P[1..40]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[2,2E]P[1..10]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[3,3E2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,2E,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[2,2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[3,3E2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,2E,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-[2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
Input Parameter Description
Parameter Value Description Notes
dm-enable YES, NO Specify if delay
measurement is
enable.
ex-dapi string The expected
( min len=0 max len=15 ) Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper string The expected operator 32 byte printable
( min len=0 max len=32 ) specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-sapi string The expected Source 15 byte printable
( min len=0 max len=15 ) Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
label string User specified Label
( min len=0 max len=64 )
tcm-mode MONITOR Facility mode is
monitor
TERMINATED Facility mode
terminated
tim-enable TIM_SAPI_ONLY Only checks for SAPI
mismatch
TIM_DAPI_ONLY Only checks for DAPI
mismatch
TIM_SAPI_DAPI Checks for SAPI and
DAPI mismatch
tx-dapi string The Destination
( min len=0 max len=15 ) Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper string The operator specific 32 byte printable
( min len=0 max len=32 ) part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi string The Source Access 15 byte printable
( min len=0 max len=15 ) Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
MT Maintenance
AID Descriptions
AID Type Format Values
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[1]P[1..40]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[2,2E]P[1..10]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[3,3E2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,2E,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[2,2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[3,3E2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[0]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[1]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[2E]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-[F]P[1..80]T[1..6]
[1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slotSsubslot- TCMTTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,2E,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-
[2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1Ttcm [1..5]S[1..4]-[2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1- [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [4,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2- [4,C2,C4,CN]P[1]-
rt3Ptp3Ttcm [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..2]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1Ttcm [3,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..5]-
port-rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1Ttcm [2,2E,F]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slotSsubslot- TCMCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
Input Parameter Description
Parameter Value Description Notes
dm-enable YES
NO
ex-dapi string The expected
( min len=0 max len=15 ) Destination Access
Point Identifier (DAPI),
provisioned by the
managing system, to
be compared with the
received DAPI at the
overhead position of
the sink for the
purpose of checking
the integrity of
connectivity.
ex-oper string The expected operator 32 byte printable
( min len=0 max len=32 ) specific part of the ASCII character string.
Trail Trace Identifier This parameter
(TTI) information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
ex-sapi string The expected Source 15 byte printable
( min len=0 max len=15 ) Access Point Identifier ASCII character string.
(SAPI), provisioned by This parameter
the managing system, supports the
to be compared with following:- printable
the received SAPI at characters from the
the overhead position ASCII range 0x20 to
of the sink for the 0x7E.- spaces
purpose of checking (supported in strings).-
the integrity of Double quotation
connectivity. marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
label string User specified Label
( min len=0 max len=64 )
tf-mode OFF Alarms off, no traffic
protection
ALMONLY Alarms on, no traffic
protection
LINEFAIL Alarms on, with traffic
protection
tim-enable TIM_SAPI_ONLY Only checks for SAPI
mismatch
TIM_DAPI_ONLY Only checks for DAPI
mismatch
TIM_SAPI_DAPI Checks for SAPI and
DAPI mismatch
tx-dapi string The Destination
( min len=0 max len=15 ) Access Point Identifier
(DAPI), provisioned by
the managing system
at the termination
source, to be placed in
the Trail Trace
Identifier (TTI)
overhead position of
the source of a trail.
tx-oper string The operator specific 32 byte printable
( min len=0 max len=32 ) part of the Trail Trace ASCII character string.
Identifier (TTI) This parameter
information, supports the following:
provisioned by the - printable characters
managing system at from the ASCII range
the termination source, 0x20 to 0x7E.- spaces
to be placed in the TTI (supported in strings).-
overhead position of Double quotation
the source of a trail. marks (must have a
backslash [\] before
each double quotation
mark) - Backslash
(must have another
backslash before it)
tx-sapi string The Source Access 15 byte printable
( min len=0 max len=15 ) Point Identifier (SAPI), ASCII character string.
provisioned by the This parameter
managing system at supports the
the termination source, following:- printable
to be placed in the characters from the
Trail Trace Identifier ASCII range 0x20 to
(TTI) overhead 0x7E.- spaces
position of the source (supported in strings).-
of a trail. Double quotation
marks (must have a
backslash [\] before
each double quotation
mark)- Backslash
(must have another
backslash before it)
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T12) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..32]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM TTP (6500-T24) TCMTTP-shelf-slot-port- TCMTTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4Ttcm [2,4,C2,C4,CN]P[1..80]-
[2,2E,3,4]P[1..8]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T12) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,4,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMTTP (6500-T24) TCMTTP-shelf-slot- TCMTTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1Ttcm [2,2E,3,4,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2Ttcm [3,C2,C4,CN]P[1]-
[0,1,2,2E,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
[4,C2,C4,CN]P[1]-
rt1Ptp1-rt2Ptp2Ttcm
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCM CTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3Ttcm [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot-port- TCMCTP-[0..992]-[91..154]-[1..2]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4,C2,C4,CN]P[1..80]-
rt4Ptp4Ttcm [2,2E,3,4]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T12) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1Ttcm [2,2E,F,C2,C4,CN]P[1]T[1..6][1..6]
ODU TCMCTP (6500-T24) TCMCTP-shelf-slot- TCMCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1- [2,4,C2,C4,CN]P[1]-
rt2Ptp2Ttcm [0,1,2,2E,3,4,F]P[1..80]T[1..6][1..6]
AID Descriptions
AID Type Format Values
TELEMETRY AID (6500 7- TELEMETRY-shelf-slot-port TELEMETRY-[0..992]-[1..6]-[5]
Slot)
TELEMETRY AID (6500 7 TELEMETRY-shelf-slot-port TELEMETRY-[0..992]-[1..8]-[5]
PKT-OPT)
TELEMETRY AID (6500 TELEMETRY-shelf-slot-port TELEMETRY-[0..992]-[1..6,9..14]-[5]
14-Slot)
TELEMETRY AID (6500 TELEMETRY-shelf-slot-port TELEMETRY-[0..992]-
32-Slot) [1..8,11..18,21..28,31..38]-[5]
Input Parameter Description
Parameter Value Description Notes
los-thresh string Telemetry Gain Loss n/a
Threshold (dBm)
targ-telem-power string Provisioned Power of n/a
the Telemetry Gain
Signal (dBm)
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
CCMD16x12 PC (6500- PC-shelf-slot-port PC-[0..992]-[1..12]-[1..24]
T12)
CCMD8X4 PC (6500-T12) PC-shelf-slotSsubslot-port PC-[0..992]-[1..12]S[1..4]-[1..8]
CCMD16x12 PC (6500- PC-shelf-slot-port PC-[0..992]-[1..24]-[1..24]
T24)
CCMD8X4 PC (6500-T24) PC-shelf-slotSsubslot-port PC-[0..992]-[1..24]S[1..4]-[1..8]
Input Parameter Description
Parameter Value Description Notes
port-select string The provisioned port of
the CP to direct traffic
towards
AID Descriptions
AID Type Format Values
SSC AIDs (6500-T12) SSC-shelf-slot-port-index SSC-[0..992]-[1..12]-[5,8]-[1..768]
SSC AIDs (6500-T24) SSC-shelf-slot-port-index SSC-[0..992]-[1..24]-[5,8]-[1..768]
Input Parameter Description
Parameter Value Description Notes
base-targ-pow string Base Target Power Range: -21.00 to 24.00
or N/A. Float in format
xxx.xx.
bias DECIMAL Provisioned
Attenuation Bias of a
Spectral Frequency
Unit.
ref-bw N/A N/A
12.5GHZ 12.5GHz
50GHZITU 50GHz ITU
PORTBW Bandwidth of the port
AID Descriptions
AID Type Format Values
NMCC AIDs (6500-T12) NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..12]-[5,8]-[1..128]-
index [1..384]
NMCC AIDs (6500-T24) NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..24]-[5,8]-[1..128]-
index [1..384]
NMCC-[0..992]-[1..12]-[5,8]-ALL
NMCC AIDs (6500-T24) NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..24]-[5,8]-[1..128]-
index [1..384]
NMCC-[0..992]-[1..24]-[5,8]-ALL
ALL NMCC on a CHC NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..12]-[5,8]-[1..128]-
(6500-T12) ALL ALL
NMCC-[0..992]-[1..12]-[5,8]-ALL
ALL NMCC on a CHC NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..24]-[5,8]-[1..128]-
(6500-T24) ALL ALL
NMCC-[0..992]-[1..24]-[5,8]-ALL
ALL NMCC on a port NMCC-shelf-slot-port-ALL NMCC-[0..992]-[1..12]-[5,8]-ALL
(6500-T12)
ALL NMCC on a port NMCC-shelf-slot-port-ALL NMCC-[0..992]-[1..24]-[5,8]-ALL
(6500-T24)
ALL NMCC on a slot NMCC-shelf-slot-ALL NMCC-[0..992]-[1..12]-ALL
(6500-T12)
ALL NMCC on a slot NMCC-shelf-slot-ALL NMCC-[0..992]-[1..24]-ALL
(6500-T24)
NMCC All Slots NMCC-shelf-ALL NMCC-[0..992]-ALL
NMCC All Slots NMCC-shelf-ALL NMCC-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
nmcc M aid
atten O WSS Current Float in format xxx.xx
Attenuation Request
center-freq M Center Frequency Range is within its
parent CHC frequency
range excluding the
parent CHC
deadbands on both
side; possible value
from 191.32500 THz to
196.08750 THz.
channel-pow M Estimated power Range: -15.00 to 24.00
across the NMCC dBm. Float in format
spectral width. xxx.xx or N/A
chc-mode M CHC Mode of the
parent CHC.
cktid O Optical Channel Circuit ASCII String
ID
ctrl-freq-offset O Control Frequency Range: +/-0 to 4800.0,
Offset. in format xxxx.x for
0.1GHz granularity.
Unit GHz. Default is 0
ctrl-out-pow M Measured Power in the Float in format xxx.xx
control bandwidth at or N/A
the output of the
control point.
ctrl-ssc O SSC-shelf-slot-port- Applicable to
index1, SSC-shelf-slot- flexiblegrid card only.
port-index2 AID of Control SSC,
may have up to two
SSCs
ctrl-ssc-atten O Attenuation that has Range: 0.00 to 28.00
been applied at the dB. Float in format
reference control SSC. xxx.xx.
Applicable to
flexiblegrid card only.
ctrl-state M Control State of the Values: Idle, Waiting
NMCC. for Power, Adding, or
Not Controlled.
ctrl-targ-pow M Target Power in the Range:-21.00 to 24.00
control bandwidth to dBm. Float in format
be achieved by the xxx.xx. Default is N/A
controller for the
NMCC in dBm.
inital-atten M Initial Attenuation Range: 0.00 to 18.00.
Float in format xxx.xx.
Default is 18 db
in-pow O Estimated Input Power Float in format xxx.xx
at the WSS input port.
in-pow-est-ref O The measured Float in format xxx.xx
snapshot of the
estimated Input Power
at the WSS input port
for a particular TCA
baseline.
in-pow-src O The Input Power Format: TID-shelf-slot-
measurement Source. port
For passthrough
channels, this point will
reference the remote
WSS output port. For
local channels, this
point will reference the
local (S)CMD input
port.
loss O Calculated WSS Loss Float in format xxx.xx
= output power - input
power
max-freq M Maximum Channel Calculated from
Frequency CENTERFREQ and
SPECTRALWIDTH.
min-freq M Minimum Channel Calculated from
Frequency CENTERFREQ and
SPECTRALWIDTH.
opaque M Opacity status of the
parent CHC. YES
indicates the Channel
is Blocked. NO
indicates the Channel
is Not Blocked.
ref-bw M Reference Bandwidth
which refers to the
frame of reference for
local controller to use.
Default is 12.5GHz for
flexiblegrid card and
50GHzITU for fixedgrid
card. Supported
values: 12.5GHz
(flexiblegrid card only),
50GHzITU.
spectral-width M Spectral Width Minimum value is 12.5
GHz. Maximum value
is limitted to its parent
CHC range and its
deadbands.
Granularity is 0.1 GHz.
sw-sel O (6500-T12) Switch
Selector. WSS Port.
Default for Demux port
is 21S6 and default for
Mux port is 21S7.
targ-loss M Target attenuation Range: 0.00 to 28.00
value to be achieved dB. Float in format
for the NMCC. xxx.xx.
targ-sw-sel M (6500-T12) Target
Switch Selector. WSS
Port.
wavelength O Wavelength of center Valid only if center
frequency frequency is on 50GHz
ITU grid.
wss-ch-in-pow M The measured power Float in format xxx.xx
in the control channel or N/A
bandwidth at the input
of WSS.
wss-ch-out-pow M The measured power Float in format xxx.xx
in the control channel or N/A
bandwidth at the
output of WSS.
wss-out-pow M The measured power Float in format xxx.xx
in the control or N/A
bandwidth at the
output of WSS.
pst O Identify the primary
state
sst O L Identify the secondary
state
AID Descriptions
AID Type Format Values
NMCC AIDs (6500-T12) NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..12]-[5,8]-[1..128]-
index [1..384]
NMCC AIDs (6500-T24) NMCC-shelf-slot-port-chcIdx- NMCC-[0..992]-[1..24]-[5,8]-[1..128]-
index [1..384]
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
Input Parameter Description
Parameter Value Description Notes
distance-long INT Span Length for Long n/a
(0-128000) Distance for OTDR
Trace (m)
distance-short INT Span Length for Short n/a
Distance OTDR Trace
(m)
event-range string OTDR Event Range n/a
(m)
fiber-type UNKNOWN Unknown fiber type
NDSF Non-Dispersion Shifted
Fiber
TWC TrueWave Classic
LS Lambda Shifted Single
Mode Fiber
DSF Dispersion Shifted
Single Mode Fiber
TWRS TrueWave Reduced
Slope
TWP TrueWave Plus
LEAF Large Effective Area
Fiber
ELEAF Enhanced Effective
Area Fiber
FL Freelight
AW Allwave
TWREACH Truewave Reach
TERALIGHT Teralight
PSC Pure Silica Core
OTHER other
NDSFLWP Non-Dispersion Shifted
Fiber Low Water Peak
TEWAVULL TeraWave ULL
EX2000 EX2000
loss-all string Loss for all events for n/a
OTDR Trace (dB)
loss-single string Loss per event for n/a
OTDR Trace (dB)
measure-time INT Acquisition Time for n/a
the OTDR Trace (s)
pulse-long INT Pulse Rate for Long n/a
Distance OTDR Trace
(ns)
pulse-short INT Pulse Rate for Short n/a
Distance OTDR Trace
(ns)
refl-all string Reflection for all n/a
events for OTDR
Trace (dB)
refl-single string Reflection for a single n/a
event for OTDR Trace
(dB)
sst AINS Auto-In-Service
AINS-DEA Auto-In-Service
Deactivate
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
Input Parameter Description
Parameter Value Description Notes
trace-type LONG LONG Trace
SHORT SHORT Trace
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
Input Parameter Description
Parameter Value Description Notes
trace-tag BSLN SOR file tagged as
baseline
CURRENT Current SOR file
trace-type LONG LONG Trace
SHORT SHORT Trace
url string The url's format is: CLI will prompt for the
( min len=0 max len=256 ) [protocol://] user password with
[user[:password]@]hos echo disabled after the
t[:port]/directory-path. command is entered.
Supported protocols:
FTP, SFTP. The URL
must be enclosed in
quotes ie.
URL="SFTP://...". If the
host is an IPv6
address, it must be
enclosed in square
brackets [].
Syntax Definition
Parameter Attributes Description Notes
byte-stream O SOR file as a byte
stream in TL1
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
trace-tag BSLN OTDR trace tagged as
baseline
CURRENT Current OTDR trace
trace-type LONG LONG Trace
SHORT SHORT Trace
Syntax Definition
Parameter Attributes Description Notes
otdrcfg M aid
distance M The distance in
meters.
effective-loss-value M The dB value of the
effective loss. Range =
-30dB to 30dB
event-type M The type of event.
Range= 0-3 (0:
INVALID, 1: LOSS, 2:
REFLECTION; 3:
SATURATE)
event-value M The dB value of the
event
loss-threshold M The dB value of the
loss threshold. Range
= 0dB to 3dB
loss-value M The dB value of the
loss. Range = -30dB to
30dB
reflection-threshold M The dB value of the
reflection threshold.
Range = -40dB to
-24dB
reflection-value M The dB value of the
reflection. Range =
-99.9dB to 0dB
result M Results
trace-date The date of the OTDR
M
trace
trace-tag O Baseline or the current
OTDR trace
trace-time M The time of the OTDR
trace
trace-type O The type of trace to be
measured
AID Descriptions
AID Type Format Values
Transponder Profile AIDs TXRXPRF-shelf-index TXRXPRF-[0..992]-[1..15]
Input Parameter Description
Parameter Value Description Notes
bias DECIMAL Bias in dB. The bias will be of the
(-10.00-10.00) format "xx.xx" and dB
will be assumed.
ctrl-freq-offset string Control Frequency Range: +/-0 to 4800.0,
Offset. in format xxxx.x for
0.1GHz granularity.
Unit GHz. Default is 0
cur-pow DECIMAL Current launch power The power will be of
(-) in dBm. the format "xx.xx" and
dBm will be assumed.
freq-res DECIMAL Captures Tx frequency The bias will be of the
(0.001-1.000) resolution of the signal. format "x.xxx" GHz.
max-freq-guard-band DECIMAL Used by SNCG to The guardband will be
(0.000-4800.000) specify the maximum of the format "xxxx.xx"
required frequency and measured in GHz.
spacing for the
previous NMC.
max-pow DECIMAL Max launch power in The power will be of
(-) dBm. the format "xx.xx" and
dBm will be assumed.
min-freq-guard-band DECIMAL Used by SNCG to The guardband will be
(0.000-4800.000) specify the maximum of the format "xxxx.xx"
required frequency and measured in GHz.
spacing for the
previous NMC.
min-pow DECIMAL Min launch power in The power will be of
(-) dBm. the format "xx.xx" and
dBm will be assumed.
min-spectral-width DECIMAL Captures Tx Network The bandwidth will be
(-) Media Channel Signal of the format
Bandwidth in GHz "xxxx.xxx" and dBm
including majority of will be assumed.
signal power, laser
aging or drift, and laser
control loop tolerance.
mod-class CUSTOM1 Custom Modulation
Class 1
CUSTOM2 Custom Modulation
Class 2
CUSTOM3 Custom Modulation
Class 3
CUSTOM4 Custom Modulation
Class 4
CUSTOM5 Custom Modulation
Class 5
CUSTOM6 Custom Modulation
Class 6
QPSK QPSK Modulation
Class
BPSK BPSK Modulation
Class
8QAM 8QAM Modulation
Class
16QAM 16QAM Modulation
Class
4ASK 4ASK Modulation
Class
UNKNOWN Unknown Modulation
Class
nom-input DECIMAL Typical per channel The power will be of
(-) operational power the format "xx.xx" and
recommended for the dBm will be assumed.
receiver in dBm.
overload-thresh DECIMAL Maximum per chanel The power will be of
(-) power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
rate DECIMAL Line Rate in Gbps. The rate will be of the
(-) format "xxxx.xx" and
Gbps will be assumed.
sensitivity-thresh DECIMAL Minimum per channel The power will be of
(-) power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
sig-bw-10dB DECIMAL Captures Tx Signal The bandwidth will be
(-) Bandwidth in GHz of the format
measured at 10 dBm "xxxx.xxx" and dBm
less than peak power. will be assumed.
sig-bw-3dB DECIMAL Captures Tx Signal The bandwidth will be
(-) Bandwidth in GHz of the format
measured at 3 dBm "xxxx.xxx" and dBm
less than peak power. will be assumed.
transmode string User specified A string of 32
Transmission Mode characters or less.
type string User specified Label A string of 64
characters or less.
TXRXPRF-[0..992]-ALL
Transponder profile all TXRXPRF-shelf-ALL TXRXPRF-[0..992]-ALL
instances
ALL objects ALL ALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
txrxprf M aid
bias O Bias in dB. The bias will be of the
format "xx.xx" and dB
will be assumed.
ctrl-freq-offset O Control Frequency Range: +/-0 to 4800.0,
Offset. in format xxxx.x for
0.1GHz granularity.
Unit GHz. Default is 0
ctrl-type O TXRX indicates the
profile is for TX/RX
controller. SIGNAL
indicates the profile is
for signal controller.
cur-pow O Current launch power The power will be of
in dBm. the format "xx.xx" and
dBm will be assumed.
freq-res O Captures Tx frequency The bias will be of the
resolution of the signal. format "x.xxx" GHz.
max-freq-guard-band O Used by SNCG to The guardband will be
specify the maximum of the format "xxxx.xx"
required frequency and measured in GHz.
spacing for the
previous NMC.
max-pow O Max launch power in The power will be of
dBm. the format "xx.xx" and
dBm will be assumed.
min-freq-guard-band O Used by SNCG to The guardband will be
specify the maximum of the format "xxxx.xx"
required frequency and measured in GHz.
spacing for the
previous NMC.
min-pow O Min launch power in The power will be of
dBm. the format "xx.xx" and
dBm will be assumed.
min-spectral-width O Captures Tx Network The bandwidth will be
Media Channel Signal of the format
Bandwidth in GHz "xxxx.xxx" and dBm
including majority of will be assumed.
signal power, laser
aging or drift, and laser
control loop tolerance.
mod-class O Modulation Class. n/a
nom-input O Typical per channel The power will be of
operational power the format "xx.xx" and
recommended for the dBm will be assumed.
receiver in dBm.
overload-thresh O Maximum per chanel The power will be of
power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
rate O Line Rate in Gbps. The rate will be of the
format "xxxx.xx" and
Gbps will be assumed.
sensitivity-thresh O Minimum per channel The power will be of
power the receiver can the format "xx.xx" and
tolerate in dBm. dBm will be assumed.
sig-bw-10dB O Captures Tx Signal The bandwidth will be
Bandwidth in GHz of the format
measured at 10 dBm "xxxx.xxx" and dBm
less than peak power. will be assumed.
sig-bw-3dB O Captures Tx Signal The bandwidth will be
Bandwidth in GHz of the format
measured at 3 dBm "xxxx.xxx" and dBm
less than peak power. will be assumed.
transmode O User specified A string of 32
Transmission Mode characters or less.
type O User specified Label A string of 64
characters or less.
File
file regidfile save Save license registration ID file
file licfile load Deliver and load license file
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
url string Supported protocols Maximum URL length
( min len=0 max len=393 ) are FTP, SFTP and is 393 characters. The
file. The full URL must password cannot
be encapsulated in contain the character
double quotes. '@'.
CLI will prompt for
Example format the user password with
[protocol:]//user:passw echo disabled after the
ord@host[:port]/directo command is entered.
ry-path.
AID Descriptions
AID Type Format Values
FCC AID FCC-shelf-fccIdx FCC-[0..992]-[1..1024]
Input Parameter Description
Parameter Value Description Notes
label string label
( min len=0 max len=64 )
prot-type WORK, PROTECT, NONE Protection Type.
sink-aid ODU CTP ODUCTP- ODUCTP- SINKAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [2,4,C2,C4
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1 [2,2E,3,4,F
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
source-aid ODU CTP ODUCTP- ODUCTP- SOURCEAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
AID Descriptions
AID Type Format Values
FCC AID FCC-shelf-fccIdx FCC-[0..992]-[1..1024]
Input Parameter Description
Parameter Value Description Notes
label string label
( min len=0 max len=64 )
Top of Flexible Cross Connect Section
xconn fcc show
Description: Retrieve FCC
CLI command: xconn fcc show
Security Level: 1
Input syntax xconn fcc show <aid>
AID Descriptions
AID Type Format Values
FCC AID FCC-shelf-fccIdx FCC-[0..992]-[1..1024]
FCC-[0..992]-ALL
FCC AID FCC-shelf-ALL FCC-[0..992]-ALL
ALL objects ALL ALL
Syntax Definition
Parameter Attributes Description Notes
fcc M FCC AID
ckt-id M Contains the
associated OSRP
Nodename and SNC.
Format is
NodeName_SNCAid
where NodeName is
the OSRP Node Name
the SNC originates
from and SNCAid is
the AID of the SNC on
the originating node.
label O label
owner M Owner Type.
protcktid M Contains the
associated Protection
OSRP Nodename and
SNC. Format is
NodeName_SNCAid
where NodeName is
the OSRP Node Name
the SNC originates
from and SNCAid is
the AID of the SNC on
the originating node.
row M Row
autocreated M If the FCC is
AUTOCREATED.
prot-type M Protection Type.
sink-aid M SINKAID
source-aid M SOURCEAID
AID Descriptions
AID Type Format Values
FCC AID FCC-shelf-fccIdx FCC-[0..992]-[1..1024]
Input Parameter Description
Parameter Value Description Notes
prot-type WORK, PROTECT, NONE Protection Type.
sink-aid ODU CTP ODUCTP- ODUCTP- SINKAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
source-aid ODU CTP ODUCTP- ODUCTP- SOURCEAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [3,C2,C4,C
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [2,4,C2,C4
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
AID Descriptions
AID Type Format Values
FCC AID FCC-shelf-fccIdx FCC-[0..992]-[1..1024]
Input Parameter Description
Parameter Value Description Notes
sink-aid ODU CTP ODUCTP- ODUCTP- SINKAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) [1..24]-
slot-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
source-aid ODU CTP ODUCTP- ODUCTP- SOURCEAID
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) [1..12]-
slot-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
VCP VCP- VCP-
Facility shelf- [0..992]-
(Unidirecti vcpIdx- [1..1024]-
onal) dir [0..1]
License
license client show Retrieve license data on the node
license server create Set license server
license server show Retrieve license server
license client audit Operates audit for licensing
license service show Retrieve license data on the node
Top of License Section
license client show
Description: Retrieve license data on the node
CLI command: license client show
Security Level: 1
Input syntax license client show [License AID] [feature-filter <Value>]
Syntax Definition
Parameter Attributes Description Notes
feature-filter O Query information for a
specific feature. Aid
should be ALL, no aid
or SHELF-shelf-ALL
while this filter is being
set.This filter allows for
returning information
about a feature that is
not currently licensed
on the shelf when the
feature name is known
(for policy information).
AID Descriptions
AID Type Format Values
License AID LICENSE-shelf-id LICENSE-[0..992]-[1..1024]
All components ALL ALL
ALL Licenses SHELF-shelf-ALL SHELF-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
feature-filter string Query information for a
specific feature. Aid
should be ALL, no aid
or SHELF-shelf-ALL
while this filter is being
set.This filter allows for
returning information
about a feature that is
not currently licensed
on the shelf when the
feature name is known
(for policy information).
Syntax Definition
Parameter Attributes Description Notes
license M License AID
arrears M Total number of
licenses in arrears on
this shelf
capacity-remainder M The remaining
capacity that can be
used before another
license is required
description Feature description
O
feature M Feature name
licensed M Total number of
licenses consumed on
this shelf
order-code O Order code(s) that
were used to order the
listed feature
policy O Policy setting for the
listed feature (can be
Strict or Preauth)
AID Descriptions
AID Type Format Values
ALL objects ALL ALL
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
audit-time time Scheduled audit time.
The format will be "HH-
MM"
primary-ip string Primary license server
IP address
protocol HTTP HTTPS protocol
HTTPS HTTP protocol
proxy OFF Proxy server is off.
ON Proxy server is on.
proxy-ip string Proxy server IP
address
proxy-port INT Proxy port number
(1-65535 Default=8080)
secondary-ip string Secondary license
server IP address
server-port INT Port number
(1-65535)
AID Descriptions
AID Type Format Values
License AID LICENSE-shelf-id LICENSE-[0..992]-[1..1024]
All components ALL ALL
ALL Licenses SHELF-shelf-ALL SHELF-[0..992]-ALL
Input Parameter Description
Parameter Value Description Notes
report SUMMATION SUMMATION report
ENTITLEMENT ENTITLEMENT report
Syntax Definition
Parameter Attributes Description Notes
license M License AID
description O Feature description
feature M Feature name
issued O Issued Date
purchased M Total number of
licenses consumed on
this shelf
used M Total number of
licenses in arrears on
this shelf
Load Management
upgrade release cancel This command is used to cancel a DLVR-RELEASE in progress
upgrade cancel Cancel Upgrade: this command is used to back out of an upgrade before it is
completed.
upgrade release check Check Release: performs pre-delivery checks for the release.
upgrade check Check Upgrade Command: this command is used to perform a health check on
the NE before running an upgrade.
upgrade commit Commit Upgrade: this command causes the new load on the node to become
the permanent load.
upgrade release save Save the network element release to an external server located at the specified
URL. After executing a SAV-RELEASE, it is recommended that a CHK-UPGRD
command be executed.
upgrade release delete Delete Release: this command is used to delete a release of a software load
stored on the SP.
upgrade release-server delete Delete the FTP Server Information.
upgrade release deliver Deliver Release: this command fetches a software load from the remote server
specified in the URL into the NE's local file system, without upgrading to it.
upgrade invoke Invoke Upgrade: cause the cards to begin execution of the new load.
upgrade load Load Upgrade: causes the new shelf controller load to be downloaded into the
file system.
upgrade release show Query Release Name(s) stored on NE
upgrade node-release show This command is used to retrieve the contents of all consolidated releases
present on the network element.
upgrade space show Retrieve Space: this command is used to retrieve the available file system
space to make sure there is enough space before putting a new release in the
file system.
upgrade state show Retrieve Upgrade State: this command is used to retrieve the progress of the
software load installation from the network element to the newly installed shelf
processor.
upgrade dependency show Retrieve Upgrade Dependencies: this command is used to retrieve the list of
equipment that have opportunistic loads and whether or not those loads have
been applied.
upgrade release-server show Retrieve Release Server: this command is used to retrieve the provisioned
release server which is used to fetch release files if missing from the local file
system.
upgrade release-server create Enter Release Server: this command provisions a release server which the
network element will use to fetch files of the current release if they are
unavailable on its local file system.
upgrade adopt-eqpt show Retrieve Adoptable Equipment: Retrieves the equipment adopted by a network
element.
upgrade srvpack show Retrieve Service Pack: Queries a network element's service packs
upgrade srvpack apply Apply Service Pack: Activates a specified service pack.
upgrade srvpack disable Remove Service Pack: Deactivates a specified service pack.
upgrade copy Prepare the pluggable transceiver for the activation of the new firmware load.
upgrade act Activate the new firmware load on the pluggable transceiver.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
relno string Release Number
combo Y Check all product
releases that are part
of the combined
release
N Check only the release
for the shelf specific
product
ip-addr ipaddr IP address of the file
server.Format is either
IPv4 (n.n.n.n) dot-
decimal notation or
IPv6 (x:x:x:x:x:x:x:x)
preferred form.
minimal Y
N
mode ftp, sftp Protocol that will be
used to connect (file
transfer mode).
optimized Y
N
path string Path 0-128 characters
pid string Password that will be CLI will prompt for the
( min len=0 max len=16 ) used during login. user password with
echo disabled after the
command is entered.
port INT Port to use.
(0-65535)
service-bundle MSPP, BB10G, BB40G, BB100G, If any Service Should be used in
BB400G, PHOTONICS, POTS, Bundle(s) is conjunction with
PTS, 6500, SITEMGR, CPL mentioned, then check MINIMAL=Y
whether the bundle parameter
loads are present in
the release server.
uid string Username that will be
( min len=0 max len=16 ) used when connecting
to server.
url string Address of server The format of url is:
( min len=0 max len=247 ) which stores loads. [protocol:]//user:passw
Full URL to remote ord@host[:port]/directo
directory inside quotes. ry-path. The password
Example: cannot contain the
ftp://user:password@h character '@'.
CLI will
ost[:port]/path/directory prompt for the user
_name, where host password with echo
must be enclosed disabled after the
within square brackets, command is entered.
i.e., [], if it is expressed
as an IPv6 address.
The password cannot
contain the character
'@'.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
relno ident ASCII string identifying
the release number.
Must be unique and
fully specified -
wildcarding is not
allowed. Example:
REL0110Z.EM
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
relno ident ASCII string identifying
the release number.
Must be unique and
fully specified -
wildcarding is not
allowed. Example:
REL0110Z.EM. The
same release name
will be used to create
the directory under the
URL that was issued
with command.
ip-addr string IP address of the file
( min len=0 max len=39 ) server.Format is either
IPv4 (n.n.n.n) dot-
decimal notation or
IPv6 (x:x:x:x:x:x:x:x)
preferred form.
mode ftp, sftp Protocol that will be
used to connect (file
transfer mode).
path string Path on external
( min len=0 max len=127 ) server where the
release is saved.
pid string Password that will be CLI will prompt for the
( min len=0 max len=16 ) used during login. user password with
echo disabled after the
command is entered.
port INT Port to use.
(0-65535)
uid string Username that will be
( min len=0 max len=16 ) used when connecting
to server.
url string URL specifies the The format of url is:
( min len=0 max len=247 ) external server protocol://user:passwo
location where the rd@host[:port]/director
release is saved. Full y-path. The password
URL to remote cannot contain the
directory inside quotes. character '@'. If any of
Example: the other optional input
ftp://user:password@h parms are provided
ost[:port]/path/directory along with a URL, then
_name, where host those values will be
must be enclosed replaced into this
within square brackets, parmeter.
CLI will
i.e., [], if it is expressed prompt for the user
as an IPv6 address. password with echo
The password cannot disabled after the
contain the character command is entered.
'@'.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
relno ident ASCII string identifying
the release number to
activate. Must be
unique and fully
specified - wildcarding
is not allowed.
Example:
REL0110Z.EM
alrms Y Upgrade should
proceed only if no
unexpected active
alarms present
N Upgrade should
proceed regardless of
alarm status
relbkup BESTEFF Best effort attempt to
save a backup of the
current release
database without
blocking the upgrade
in case of failure
REQD Proceed with load
upgrade only if saving
a backup of the current
release database is
successful
NONE Proceed with load
upgrade without saving
a backup of the current
release database
Top of Load Management Section
upgrade release show
Description: Query Release Name(s) stored on NE
CLI command: upgrade release show
Security Level: 1
Input syntax upgrade release show [aid] [inc-service-bundle <Value>]
Syntax Definition
Parameter Attributes Description Notes
inc-service-bundle O The bundle status
values are
DELIVERED or
RECOMMENDED
depending whether
they are fully delivered
or recommended in the
shelf.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
inc-service-bundle Y
N
Syntax Definition
Parameter Attributes Description Notes
shelf M Equipment reporting in
format of a Shelf AID
(e.g. SHELF-1)
status M If the release was
determined to be
('INCOMPLETE' or
'COMPLETE' or
'PARTIAL')
version M Release that is present
(e.g. 'REL0200P.DV')
bb100g O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
bb10g O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
bb400g O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
bb40g O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
cpl O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
mspp O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
ome-6500 O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
photonics O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
pots O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
pts O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
sitemgr O If the service bundles
were determined to be
delivered (DLVRD) or
recommended
(RCMD)
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
relno ident ASCII string identifying
the service pack to
deactivate. Must be
unique and fully
specified - wildcarding
is not allowed.
Example:
REL0110Z.EM
Member
shelves member create Creates the MEMBER Optical Facility.
shelves member set Edits the MEMBER Optical Facility.
shelves member show Retrieves the MEMBER Optical Facility.
shelves member-session show Retrieves TL1 communication status of shelves in a consolidated TID.
shelves member disable Puts shelf in a Consolidated TID in an out of service state. It may be executed
at any time from the primary to place a member shelf out of service. Can only
be executed by a member shelf when the primary is unreachable from the
member shelf. This does not remove a shelf from service, as optical
connections may persist, and a node being converted to standalone may still
intend to carry traffic.
shelves member enable Restores a shelf member to a managed in-service state through a TID
consolidation primary.
shelves member delete Deletes a shelf member from a TID consolidation primary. On a member, this
command deletes the primary, but only if the primary is unreachable via OAM
Comms.
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
ip-addr ipaddr The IP address to be The IP address must
( min len=0 max len=15 ) given out on the be in the standard dot
CRAFT LAN port. notation, n.n.n.n
Format is IPv4
(n.n.n.n) dot-decimal
notation.
member-func CHA Channel Access
AMP Line Amplifier
OCP Optical Convergence
Platform
POTS Packet Optical
Transport System
POP Photonic Optimized
Platform
state IS In Service
OOS-MA Out of Service -
Management
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
ip-addr ipaddr The IP address to be The IP address must
( min len=0 max len=15 ) given out on the be in the standard dot
CRAFT LAN port. notation, n.n.n.n
Format is IPv4
(n.n.n.n) dot-decimal
notation.
member-func CHA Channel Access
AMP Line Amplifier
OCP Optical Convergence
Platform
POTS Packet Optical
Transport System
POP Photonic Optimized
Platform
Network Topology
network adjacency all show Retrieve autodiscovery information from all points that currently exist on a NE.
OSRP
osrp config create Create OSRP provisioning.
osrp config set Edit OSRP provisioning.
osrp config delete Delete OSRP provisioning.
osrp config show Retrieve OSRP provisioning.
osrp node set Edit the local OSRP node.
osrp node show Retrieve the local OSRP node.
osrp remote-node show Retrieve remote OSRP nodes.
osrp line set Edit a local OSRP line.
osrp line disable Place a local OSRP line into an out-of-service state for maintenance.
osrp line enable Restore a local OSRP line from a maintenance out-of-service state.
osrp line delete Delete a local OSRP line.
osrp line-ovpn set Edit the OVPN of a local OSRP line.
osrp line-snc show Retrieve SNCs on this OSRP line.
osrp line show Retrieve local OSRP lines.
osrp link create Create a local OSRP link.
osrp link set Edit a local OSRP link.
osrp link delete Delete a local OSRP link.
osrp link-snc show Retrieve SNCs on this OSRP link.
osrp link show Retrieve local OSRP links.
osrp link-metrics show Retrieve local OSRP link metrics.
osrp remote-link show Retrieve remote OSRP links.
osrp remote-link-metrics show Retrieve remote OSRP link metrics.
osrp dtl create Create a local Designated Transit List.
osrp dtl set Edit a local Designated Transit List.
osrp dtl delete Delete a local Designated Transit List.
osrp dtl show Retrieve local Designated Transit Lists.
osrp casc-dtl create Create a local Cascaded Designated Transit List.
osrp casc-dtl set Edit a local Cascaded Designated Transit List.
osrp casc-dtl delete Delete a local Cascaded Designated Transit List.
osrp casc-dtl show Retrieve local Cascaded Designated Transit Lists.
osrp dtl-set create Create a local Designated Transit List set.
osrp dtl-set set Edit a local Designated Transit List set.
osrp dtl-set delete Delete a local Designated Transit List set.
osrp dtl-set show Retrieve local Designated Transit List sets.
osrp non-viable-dtl-set create Create a local Non-Viable Designated Transit List set.
osrp snc create Create a Subnetwork Connection.
osrp snc set Edit a Subnetwork Connection.
osrp snc disable Place a Subnetwork Connection into an out-of-service state for
maintenance.
osrp snc enable Restore a Subnetwork Connection from a maintenance out-of-service state.
osrp snc delete Delete a Subnetwork Connection.
osrp snc show Retrieve Subnetwork Connections originating and terminating on the node.
osrp snc-diag show Retrieve Subnetwork Connection diagnostics on the originating node.
osrp snc clear-diag Clear Subnetwork Connection diagnostics on the originating node.
osrp snc-ee-diag show Retrieve Subnetwork Connection end-to-end data plane diagnostics on the
originating node.
osrp snc-route show Retrieve Subnetwork Connection routes on the originating node.
osrp snc-group create Create a Subnetwork Connection Group
osrp snc-group set Edit a Subnetwork Connection Group on the originating node
osrp snc-group disable Place a Subnetwork Connection Group into an out-of-service maintenance
state
osrp snc-group enable Restore a Subnetwork Connection Group from a maintenance out-of-
service state in to an in-service state
osrp snc-group delete Delete a Subnetwork Connection Group and all of it's Subnetwork
Connection members.
osrp snc-group show Retrieve Subnetwork Connections Group on the originating node.
osrp snc-group-diag show Retrieve Subnetwork Connection Group diagnostics on the originating
node.
osrp snc-group clear-diag Clear Subnetwork Connection Group diagnostics on the originating node.
osrp snc-group-route show Retrieve Subnetwork Connection Group routes on the originating node.
osrp corouted-snc create Create a Co-Routed Subnetwork Connection
osrp corouted-snc set Edit a Co-Routed Subnetwork Connection on the originating node
osrp corouted-snc disable Place a Co-Routed Subnetwork Connection into an out-of-service
maintenance state
osrp corouted-snc enable Place a Co-Routed Subnetwork Connection into an in-service maintenance
state.
osrp corouted-snc delete Delete a Co-Routed Subnetwork Connection and all of it's Subnetwork
Connection members.
osrp corouted-snc show Retrieve Co-Routed Subnetwork Connections on the originating node.
osrp corouted-snc-diag show Retrieve Co-Routed Subnetwork Connection diagnostics on the originating
node.
osrp corouted-snc clear-diag Clear Co-Routed Subnetwork Connection diagnostics on the originating
node.
osrp corouted-snc add-member Add a member to a Co-Routed Subnetwork Connection.
osrp corouted-snc delete-member Delete a member from a Co-Routed Subnetwork Connection.
osrp corouted-snc-route show Retrieve Co-Routed Subnetwork Connection routes on the originating node.
osrp todrprofile create Create time of day reversion profile.
osrp todrprofile set Edit time of day reversion profile.
osrp todrprofile delete Delete a time of day reversion profile.
osrp todrprofile show Retrieve time of day reversion profile.
osrp lag create Create an OSRP Link Aggregation Group.
osrp lag set Edit an OSRP Link Aggregation Group.
osrp lag delete Delete an OSRP Link Aggregation Group.
osrp lag show Retrieve OSRP Link Aggregation Groups.
AID Descriptions
AID Type Format Values
OSRP AID OSRP-shelf-id OSRP-[0..992]-[1]
OSRP0 AID OSRP0-shelf-id OSRP0-[0..992]-[1]
Input Parameter Description
Parameter Value Description Notes
node-id string A node ID that is Format: 4 character
( min len=4 max len=4 ) unique across the hexadecimal value.
OSRP network.
node-name string An OSRP node name Format: ASCII
( min len=1 max len=20 ) character string.{A-
that is unique across
the OSRP network. Z,a-z,0-9 and '-'} are
the only supported
characters.
tl1-ip-addr ipaddr The IP address OSRP The address is used
( min len=7 max len=15 ) floods through the by management
network.Format is IPv4 systems to discover
(n.n.n.n) standard dot- the IP address of the
decimal notation TL-1 interface of all
shelves in the
network.Format is IPv4
(n.n.n.n) standard dot-
decimal notation
type DERIVED The type of CONTROL If no XC/CTM
plane to be configured equipment is currently
is derived from the configured, the
type of XC/CTM command is rejected.
equipment currently
configured on the
shelf.
OTN For RTRV only
PROV Photonic CONTROL
plane in Provisioning
only mode is to be
configured.
udp-port INT Local UDP port for out- This parameter is not
(51001-52000 Default=51001) of-band connectivity. applicable to OTN.
AID Descriptions
AID Type Format Values
OSRP AID OSRP-shelf-id OSRP-[0..992]-[1]
OSRP0 AID OSRP0-shelf-id OSRP0-[0..992]-[1]
Input Parameter Description
Parameter Value Description Notes
tl1-ip-addr ipaddr The IP address OSRP The address is used
( min len=7 max len=15 ) floods through the by management
network.Format is IPv4 systems to discover
(n.n.n.n) standard dot- the IP address of the
decimal notation TL-1 interface of all
shelves in the
network.Format is IPv4
(n.n.n.n) standard dot-
decimal notation
udp-port INT Local UDP port for out- This parameter is not
(51001-52000) of-band connectivity. applicable to OTN.
AID Descriptions
AID Type Format Values
OSRP node AID OSRPNODE-shelf-id OSRPNODE-[0..992]-[1]
Photonic OSRP node AID OSRPNODE0-shelf-id OSRPNODE0-[0..992]-[1]
Input Parameter Description
Parameter Value Description Notes
bw-thresh-mode AUTO Bandwidth threshold is
aumactically set
MANUAL Bandwidth threshold is
manually set
ADV_ALL Advertise total
available ODUk
bandwidth
flt-holdoff-timer INT Specifies Fault release For SONET/SDH and
(10000-900000) hold-off time in OTN, steps of 5
milliseconds. milliseconds are
accepted up to a
maximum of 10000
milliseconds. For
photonics, steps of
5000 milliseconds are
accepted up to a
maximum of 3600000
milliseconds.
holdoff-timer INT Specifies low priority For SONET/SDH and
(0-3600000) connection release OTN, steps of 5
hold-off time in milliseconds are
milliseconds. accepted up to a
maximum of 10000
milliseconds. For
photonics, steps of
5000 milliseconds are
accepted up to a
maximum of 3600000
milliseconds.
inhibit-path-events YES
NO
low-prio-holdoff-ctrl-line- YES, NO Specifies the control A value of NO
state behavior for releasing specifies the behavior
low priority is to release the
connections after the connections after the
hold-off timer expiry by hold-off timer expires
checking the line state. even if the line is up.
low-prio-holdoff-feature YES, NO Specifies if low priority
connections hold-off
release when a line
goes down.
make-before-break YES, NO Specifies if the Make Make Before Break
Before Break capability provides the
is available. functionality of creating
a new SNC Path
before traffic
switchover or during a
mesh restoration. This
parameter is only
applicable to OTN.
osrp-blocked-node- UNLOCKED, LOCKED Specifies the blocked
admin-st node feature's
administrative state.
osrp-blocked-node- YES, NO Specifies if node
feature blocking is allowed.
osrp-line-tcm-level INT OSRP line default This parameter is only
(1-6) TCM. applicable to OTN.
osrp-snc-tcm-level INT OSRP SNC default This parameter is only
(1-6) TCM. applicable to OTN.
otu2-bw-thresh string Node level global Format is a quoted
( min len=60 max len=91 ) default values of string with the
Bandwidth Threshold following format:
for OTU2 line type.It "oduvalue:ODU0&odu
will be used to initialize value:ODU1&oduvalue
OSRPLINK Bandwidth :ODU2&bps:ODUFLE
Threshold Values XRSZ&bps:ODUFLEX
whenever NRSZ". 'oduvalue' is
BWTHRMODE is set the value of the
to Manual. specified ODUn. This
parameter is only
applicable to OTN.
otu2ebwt string Node level global Format is a quoted
( min len=60 max len=91 ) default values of string with the
Bandwidth Threshold following format:
for OTU2E line type.It "oduvalue:ODU0&odu
will be used to initialize value:ODU1&oduvalue
OSRPLINK Bandwidth :ODU2&oduvalue:OD
Threshold Values U2E&bps:ODUFLEXR
whenever SZ&bps:ODUFLEXNR
BWTHRMODE is set SZ". 'oduvalue' is the
to Manual. value of the specified
ODUn. This parameter
is only applicable to
OTN.
otu3-bw-thresh string Node level global Format is a quoted
( min len=77 max len=112 ) default values of string with the
Bandwidth Threshold following format:
for OTU3 line type.It "oduvalue:ODU0&odu
will be used to initialize value:ODU1&oduvalue
OSRPLINK Bandwidth :ODU2&oduvalue:OD
Threshold Values U2E&oduvalue:ODU3
whenever &bps:ODUFLEXRSZ&
BWTHRMODE is set bps:ODUFLEXNRSZ".
to Manual. 'oduvalue' is the value
of the specified ODUn.
This parameter is only
applicable to OTN.
otu3e2-bw-thresh string Node level global Format is a quoted
( min len=77 max len=112 ) default values of string with the
Bandwidth Threshold following format:
for OTU3E2 line type. "oduvalue:ODU0&odu
It will be used to value:ODU1&oduvalue
initialize OSRPLINK :ODU2&oduvalue:OD
Bandwidth Threshold U2E&oduvalue:ODU3
Values whenever &bps:ODUFLEXRSZ&
BWTHRMODE is set bps:ODUFLEXNRSZ".
to Manual. 'oduvalue' is the value
of the specified ODUn.
This parameter is only
applicable to OTN.
otu4-bw-thresh string Node level global Format is a quoted
( min len=86 max len=124 ) default values of string with the
Bandwidth Threshold following format:
for OTU4 line type.It "oduvalue:ODU0&odu
will be used to initialize value:ODU1&oduvalue
OSRPLINK Bandwidth :ODU2&oduvalue:OD
Threshold Values U2E&oduvalue:ODU3
whenever &oduvalue:ODU4&bps
BWTHRMODE is set :ODUFLEXRSZ&bps:
to Manual. ODUFLEXNRSZ".
'oduvalue' is the value
of the specified ODUn.
This parameter is only
applicable to OTN.
retain-home-path- YES
capability NO
revert-timer SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
snc-integrity-check ON, OFF Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
snic-timer INT Specifies the SNIC This parameter is only
(0-150) timer value in seconds. applicable to OTN.
timed-revert INT Amount of time for a Not applicable when
(300-86400) connection to be MESHRST is set to
reverted to the original OFF. This parameter
route (sec). is only applicable to
OTN. A newly created
SNC gets its default
TRVRT value from this
global value on OSRP
Node.
tod-revert-holdback YES
NO
tod-revert-holdback- time Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
value will be used as a
default value for the
attribute TODRHBPRD
of a new created SNC.
This parameter is only
applicable to OTN.
tod-revert-period INT Specifies the time Mandatory if TODR is
(5-300) range (in minutes) set. This parameter is
when it's acceptable to only applicable to
do the TODR (home OTN. A newly created
route must be SNC gets its default
available during this TODRPERIOD value
window), otherwise from this global value
wait 24 hours to try on OSRP Node.
again.
tod-revert-time time Specifies the time of Format is HH-MM, i.e.
day when to do 02-05 or 22-59. Range
reversion to the home is 00-00 to 23-59. This
path (home path must parameter is only
be available). applicable to OTN. A
newly created SNC
gets its default
TODRTIME value from
this global value on
OSRP Node.
AID Descriptions
AID Type Format Values
OSRP remote nodes AID OSRPRMTNODES-shelf-id OSRPRMTNODES-[0..992]-[1]
Photonic OSRP remote OSRPRMTNODES0-shelf-id OSRPRMTNODES0-[0..992]-[1]
nodes AID
All remote Photonic OSRP OSRPRMTNODES0-shelf-ALL OSRPRMTNODES0-[0..992]-ALL
nodes on shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbrfilter string Specifies OSRP node Maximum of 20
( min len=1 max len=40 ) retrieval filter values. characters for
photonics. Values:
NEIGHBOR,
REMOTE, <node
name>
Syntax Definition
Parameter Attributes Description Notes
aid M aid
local M Locality of the remote
node.
make-before-break O Specifies if the Make Make Before Break
Before Break capability provides the
is available. functionality of creating
a new SNC Path
before traffic
switchover or during a
mesh restoration. This
parameter is only
applicable to OTN.
neighbor-peer-node- M State of the FSM If a remote node is not
state (Finite State Machine) a neighbor node, the
for the neighboring NBRPS parameter will
peer node, with display NOT_APPL.
respect to the node
where this command is
issued.
osrp-blocked-node- M Operational state of
oper-st the blocked node.
osrp-node-id M OSRP node ID. Format: Hexadecimal
(22 bytes) / String (44
chars).
osrp-node-name M OSRP node name. Maximum of 20
characters for
photonics.
osrp-node-type M OSRP node type. 6500_2 is for future
use. The value 6500,
6500_CS and 6500_T
are for photonics only
and are the only
values applicable to
photonics.
ovpn-capability O Specifies if OVPN This parameter is only
enhancement applicable to OTN.
capability is enabled.
retain-home-path- O Specifies if the Retain Retain Home Path
capability Home Path capability provides the
is available. functionality of
retaining to the home
path and also updating
the current path to the
home path if needed.
This parameter is only
applicable to OTN.
tl1-ip-addr M The IP address OSRP The address is used
floods through the by management
network.Format is IPv4 systems to discover
(n.n.n.n) standard dot- the IP address of the
decimal notation TL-1 interface of all
shelves in the
network.Format is IPv4
(n.n.n.n) standard dot-
decimal notation
AID Descriptions
AID Type Format Values
OSRP line AID (6500-T12) OSRPLINE-shelf-slot-port OSRPLINE-[0..992]-[1..12]-[1..255]
OSRP line AID (6500-T24) OSRPLINE-shelf-slot-port OSRPLINE-[0..992]-[1..24]-[1..255]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
Photonic OSRP line AID OSRPLINE0-shelf-id OSRPLINE0-[0..992]-[1..1599238]
(6500 T-12)
Input Parameter Description
Parameter Value Description Notes
apr-action OOS If selected, OSRP After domain goes to
should initiate mesh- dark, OSRP should
restoration operation continue to block the
on the existing faulted line and raise
channels if the domain 'OSRP Line
is lit. Operationally Blocked'
alarm and Once the
fault condition gets
cleared, OSRP should
clear the 'OSRP Line
Operationally Blocked'
alarm and unblock the
link
BLOCK If selected, OSRP OSRP should block
should NOT trigger the faulted link and
mesh-restoration raise 'OSRP Line
operation on the Operationally Blocked'
existing channels if the alarm and once the
domain is lit. fault condition gets
cleared, OSRP should
clear the 'OSRP Line
Operationally Blocked'
alarm
bw-lockout-enabled YES, NO Specifies if bandwidth When set to YES, the
lockout is enabled OSRP line will no
locally for the OSRP longer be used for
line. establishing new
SNCs and existing
SNCs that are
currently using the
OSRP line will not be
impacted. This
parameter is not
applicable to
SONET/SDH.
common-id INT Common identifier of This ID is unique
(1-65534) the OSRP line. within the containing
OSRP link.
hold-off INT Holdoff for the OSRP Line-Level hold-off
(0-5000) line. timer delays the switch
of traffic off a line until
the end of the time
period. If the
downstream failure is
no longer present, the
line shall not switch
traffic off the line. A
value of 'zero' shall
disable the hold-off
timer. Range: 0, 50ms
to 5sec increments of
10ms. Acceptable
Value: 0 or 50 to 5000
in the increments of
10.
ignore-faults YES, NO Specifies if faults are When set to YES,
to be ignored for this faults will not cause
OSRP line. SNC mesh
restorations. This
parameter is only
applicable to
photonics.
label string Label for the OSRP
( min len=0 max len=40 ) line.
major-high-fiber-loss- OOS If selected, OSRP After domain goes to
action should initiate mesh- dark, OSRP should
restoration operation continue to block the
on the existing faulted line and raise
channels if the domain 'OSRP Line
is lit. Operationally Blocked'
alarm and Once the
fault condition gets
cleared, OSRP should
clear the 'OSRP Line
Operationally Blocked'
alarm and unblock the
link
BLOCK If selected, OSRP OSRP should block
should NOT trigger the faulted link and
mesh-restoration raise 'OSRP Line
operation on the Operationally Blocked'
existing channels if the alarm and once the
domain is lit. fault condition gets
cleared, OSRP should
clear the 'OSRP Line
Operationally Blocked'
alarm
NONE If selected, OSRP
should ignore the fault
and do nothing.
oob-common-id INT Common ID for out-of- This should be unique
(1-65534) band connectivity. among all out-of-band
lines to a given remote
node. This parameter
is not applicable to
OTN.
osrp-link OSRP link OSRPLINK OSRPLIN Local OSRP link in Format: OSRPLINK
AID -shelf- K-[0..992]- which this OSRP line AID. This parameter is
id [1..419430 is being aggregated. not applicable to
3] photonics.
psnc-cse-action KEEP All SNCs using the
OSRP line are not
impacted on call status
failure.
RELEASE All SNCs using the
OSRP line are
Released on call
status failure.
span-loss-exceeded- OOS All non-permanent
action SNCs using the OSRP
line are deleted or
mesh restored. The
OSRP line will no
longer be used for
establishing new
SNCs.
BLOCK The SNCs using the
OSRP line are not
impacted. The OSRP
line will no longer be
used for establishing
new SNCs.
NONE Do nothing.
unblock YES, NO This will allow user to The user shall only be
modify after the fiber able to set the attribute
disconnect has been from No to Yes.
fixed. OSRP-LINE is
latched to blocked
state when this is set
to NO, Triggered by
the s/w, and need to
manually set it back to
YES in order to
unblock the OSRP-
LINE and allow traffic
to be added on that
line.
Syntax Definition
Parameter Attributes Description Notes
osrp-line M aid
egress-link-id O ID of the egress OSRP
link.
end-pt-size O End-point size type for
the SNC.
ingress-link-id O ID of the ingress
OSRP link.
is-home-path O Specifies whether SNC
is currently in its home
path or not.
orig-node-name M Name of the SNC
originating node.
ovpn-id O The optical virtual
private network ID.
priority M Priority level of this
SNC connection.
rhp-capability O Specifies if the Retain
Home Path capability
is available.
snc-name M Specifies the SNC
name.
state O Indicates the state of
the call
AID Descriptions
AID Type Format Values
OSRP line AID (6500-T12) OSRPLINE-shelf-slot-port OSRPLINE-[0..992]-[1..12]-[1..255]
OSRP line AID (6500-T24) OSRPLINE-shelf-slot-port OSRPLINE-[0..992]-[1..24]-[1..255]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T12) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..12]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
OSRP line AID (6500-T24) OSRPLINE-shelf-slotSsubslot- OSRPLINE-[0..992]-[1..24]S[1..3]-
port [1..12]
Photonic OSRP line AID OSRPLINE0-shelf-id OSRPLINE0-[0..992]-[1..1599238]
(6500 T-12)
All OSRP lines on shelf OSRPLINE-shelf-ALL OSRPLINE-[0..992]-ALL
All photonic OSRP lines on OSRPLINE0-shelf-ALL OSRPLINE0-[0..992]-ALL
shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbrfilter string Specifies OSRP line Specifies if the OSRP
retrieval filter. line with the specific
local supporting
termination point
(LCLSUPTP) is to be
retrieved. Format:
<bay>-<A|C>-<slot>-
<port> for
SONET/SDH, <bay>-
<A|C>-<slot>-<port>
or FTTP AID for OTN,
ADJ AID for photonics.
Syntax Definition
Parameter Attributes Description Notes
aid M aid
apr-action O Specifies the OSRP This parameter is only
action when Automatic a user-provisionable
Power Reduction parameter applicable
alarm is raised to photonics.User can
somewhere on the configure maximum of
line. SPANLOSSEXCACTI
ON severity
avail-base-bw O The available This parameter is only
bandwidth this line has applicable to OTN.
left on the base link.
base-ovpn-id O The base OVPN ID of This parameter is only
the base link. applicable to OTN.
bw-lockout-enabled O Specifies if bandwidth A value of YES
lockout is enabled indicates that the
locally for the OSRP OSRP line will not be
line. used for establishing
new SNCs. This
parameter is not
applicable to
SONET/SDH.
common-id M Common identifier of This ID is unique
the OSRP line. within the containing
OSRP link.
delay O Indicates the physical This parameter is only
(measured) delay in applicable to OTN.
milliseconds for the
OSRP line.
hold-off O Line-Level hold-off
timer delays the switch
of traffic off a line until
the end of the time
period. If the
downstream failure is
no longer present, the
line shall not switch
traffic off the line. A
value of 'zero' shall
disable the hold-off
timer. Range: 0, 50ms
to 5sec increments of
10ms. Acceptable
Value: 0 or 50 to 5000
in the increments of
10.
ignore-faults O Specifies if faults are When set to YES,
to be ignored for this faults will not cause
OSRP line. SNC mesh
restorations. This
parameter is only
applicable to
photonics.
label M Label for the OSRP
line.
line-type O The physical line type. Values OC3, OC12,
OC48, and OC192 are
only applicable to
SONET/SDH. Value
OMS is only applicable
to Photonics. Other
values are only
applicable to OTN.
local-supp-tp M Local supporting Format: <bay>-<A|C>-
termination point <slot>-<port> for
indicating the physical SONET/SDH, <bay>-
port of the termination <A|C>-<slot>-<port>
point of the line. or FTTP AID for OTN,
ADJ AID for photonics.
major-high-fiber-loss- O Specifies the OSRP This parameter is only
action action when Major a user-provisionable
High Fiber Loss alarm parameter applicable
is raised somewhere to photonics.User can
on the line. configure maximum of
APRACTION severity
oob-common-id O Common ID for out-of- This is unique among
band connectivity. all out-of-band lines to
a given remote node.
This parameter is not
applicable to OTN.
osrp-link M Local OSRP link in Format: OSRPLINK
which this OSRP line AID.
is being aggregated.
ovpn-bw O L The bandwidth list that This parameter is only
corresponds to the applicable to OTN.
OVPN ID list
ovpn-id-count O The number of Optical This parameter is only
Virtual Private applicable to OTN.
Networks which this
line belongs to.
ovpn-ids O L The Optical Virtual This parameter is only
Private Network ID list applicable to OTN.
ovpn-link-ids O L The OSRPLINK ID list This parameter is only
which corresponds to applicable to OTN.
the OVPN ID list.
psnc-cse-action O Specifies the behavior
on Call status failure.
This parameter is only
applicable to
photonics.
remote-bw-lockout- O Specifies the remote When set to YES, the
enabled bandwidth lockout OSRP line will no
value. longer be used for
establishing new
SNCs. This parameter
is not applicable to
SONET/SDH.
remote-common-id O Common ID of the This is unique within
remote line. the containing link.
remote-delay O Measured delay value This parameter is only
on the remote line (in applicable to OTN.
microseconds).
remote-label O Label of the remote
line.
remote-node-name O Name of the remote This will be empty if
node. this is unavailable.
Maximum of 20
characters for
photonics.
remote-osrp-link-id O ID of the remote OSRP Value is 1 to 2048 for
link in which the SONET/SDH and
remote line is OTN, and 1 to 25438
aggregated. for photonics.
remote-ovpn-bw O L The remote bandwidth This parameter is only
list that corresponds to applicable to OTN.
the OVPN ID list
remote-ovpn-ids O L The Remote Optical This parameter is only
Virtual Private Network applicable to OTN.
ID list
remote-pst O Primary state of the For OTN, this
remote line. parameter will not
show when the
OSRPLINE is not
connected.
remote-state O Specifies the current This parameter is only
state of the remote applicable to
OSRP line. photonics.
remote-supp-tp O Remote supporting Format: <bay>-<A|C>-
termination point <slot>-<port> for
indicating the physical SONET/SDH, <bay>-
port of the termination <A|C>-<slot>-<port>
point of the line. or FTTP AID for OTN,
ADJ AID for photonics.
span-loss-exceeded- O Specifies the behavior
action on
SPANLOSSEXCEEDE
D. This parameter is
only applicable to
photonics.
state O Specifies the current This parameter is only
state of the local applicable to
OSRP line. photonics.
tod-rhb-sdc-ln-time O Specifies date and This parameter is only
time when OSRP line applicable to OTN.
became available for
TODR reversion
total-bw O The total bandwidth This parameter is only
this line was applicable to OTN.
provisioned with.
unblock O This will allow user to The user shall only be
modify after the fiber able to set the attribute
disconnect has been from No to Yes.
fixed. OSRP-LINE is
latched to blocked
state when this is set
to NO, Triggered by
the s/w, and need to
manually set it back to
YES in order to
unblock the OSRP-
LINE and allow traffic
to be added on that
line.
pst M Primary state of the
OSRP line.
AID Descriptions
AID Type Format Values
OSRP link AID OSRPLINK-shelf-id OSRPLINK-[0..992]-[1..4194303]
Photonic OSRP link AID OSRPLINK0-shelf-id OSRPLINK0-[0..992]-[1..1599238]
(6500-T12)
Input Parameter Description
Parameter Value Description Notes
adm-weight INT It is also referred to as
Administrative weight
(1-65535) link usage cost. The
which specifies the
OSRP links with the
level of importance
given to the OSRP lowest weight are
link. preferred during route
computation for SNCs
that are minimized by
weight.
bw-adv-limit ODU0_AND_UP, ODU1_AND_UP, Advertisement limit on Values
ODU2_AND_UP, ODU3_AND_UP, an OTN and out-of- ODU0_AND_UP,
ODU2E_AND_UP, band link. ODU1_AND_UP,
ODU4_AND_UP, OOB1C_ONLY, ODU2_AND_UP,
OOB3C_ONLY, OOB12C_ONLY, ODU3_AND_UP, and
OOB24C_ONLY, OOB48C_ONLY, ODU2E_AND_UP are
OOB192C_ONLY, applicable to OTN
NOT_APPLICABLE only. Values
OOB1C_ONLY,
OOB3C_ONLY,
OOB12C_ONLY,
OOB24C_ONLY,
OOB48C_ONLY,
OOB192C_ONLY, are
applicable to
SONET/SDH only.
This parameter is not
applicable to
photonics.
bw-thresh-mode AUTO Bandwidth threshold is
aumactically set
MANUAL Bandwidth threshold is
manually set
ADV_ALL Advertise total
available ODUk
bandwidth
constraint-flood-enabled YES, NO Enables or disables This parameter is only
constraint flooding on applicable to OTN.
a link.
holdback-signal- INT Holdback signal This parameter is only
degrade-thresh (5-12) degrade threshold. applicable to OTN.
label string Label of the OSRP
( min len=0 max len=64 ) link.
latency-discovery- YES, NO Enables or disables Only applicable to
enabled latency discovery. master node. Only
applicable to OTN.
manual-delay INT Provisioned override This parameter is only
(1-200000) delay for this OSRP applicable to OTN.
link (in microseconds).
odu0-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU0)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU0) ceiling,
over which no
bandwidth updates are
sent.
odu1-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU1)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU1) ceiling,
over which no
bandwidth updates are
sent.
odu2-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU2)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU2) ceiling,
over which no
bandwidth updates are
sent.
odu2e-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU2E)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU2E) ceiling,
over which no
bandwidth updates are
sent.
odu3-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU3)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU3) ceiling,
over which no
bandwidth updates are
sent.
odu4-bw-thresh INT The Bandwidth This parameter is only
(0-16000) Threshold sets the applicable to OTN.
maximum number of
bandwidth units (here
unit of ODU4)
advertised for a link. It
also serves as a
bandwidth unit (here
unit of ODU4) ceiling,
over which no
bandwidth updates are
sent.
odu-flex-nrsz-bw-thresh string The Bandwidth This parameter is only
( min len=1 max len=19 ) Threshold shows the applicable to OTN.
maximum number of
bandwidth units (in
Bps) for Non-
Resizable ODU Flex
advertised for a link.
odu-flex-rsz-bw-thresh string The Bandwidth This parameter is only
( min len=1 max len=19 ) Threshold shows the applicable to OTN.
maximum number of
bandwidth units (in
Bps) for Resizable
ODU Flex advertised
for a link.
oob-enable YES, NO Specifies whether out- This parameter is not
of-band signaling is applicable to OTN.
enabled on this OSRP
link.
oob-rmt-ip ipaddr Remote IP address of This parameter is not
( min len=7 max len=15 ) OSRP node for out-of- applicable to
band OTN.Format is IPv4
connectivity.Format is (n.n.n.n) standard dot-
IPv4 (n.n.n.n) standard decimal notation
dot-decimal notation
oob-rmt-node-id INT Remote node ID for This parameter is not
(1-65535) out-of-band applicable to OTN.
connectivity.
oob-rmt-udp-port INT Remote UDP port for This parameter is not
(51001-52000) out-of-band applicable to OTN.
connectivity.
osrp-lines OSRP line OSRPLINE OSRPLIN List of OSRP lines that Grouping (&) is
AID (6500- E-[0..992]- are aggregated to supported. The
-shelf-
T12) slot- [1..12]- make up this OSRP OSRPLINK
port [1..255] link. parameters of the
OSRP lines are
OSRP line OSRPLINE OSRPLIN changed to point to
AID (6500- -shelf- E-[0..992]- this OSRP link as a
T24) slot- [1..24]- result of this
port [1..255] command. If an OSRP
OSRP line OSRPLINE OSRPLIN line specified in this list
AID (6500- -shelf- E-[0..992]- was previously in
T12) [1..12]S[1.. another OSRP link, the
slotSsub
3]- OSRP line and its
slot-
[1..5]S[1..4 previous link are both
portSsub updated by the editing
]
port of this OSRP link.
OSRP line OSRPLINE OSRPLIN Specifies a list of
AID (6500- -shelf- E-[0..992]- OSRP lines (0 to 20 of
T12) slotSsub [1..12]S[1.. them) in the following
slot- 3]-[1..12] format:
OSRPLINE_AID&OSR
port
PLINE_AID&... This
OSRP line OSRPLINE OSRPLIN parameter is not
AID (6500- -shelf- E-[0..992]- applicable to
T12) slotSsub [1..12]S[1.. photonics.
slot- 3]-[1..12]
port
OSRP line OSRPLINE OSRPLIN
AID (6500- -shelf- E-[0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]
port
OSRP line OSRPLINE OSRPLIN
AID (6500- -shelf- E-[0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]
port
OSRP line OSRPLINE OSRPLIN
AID (6500- -shelf- E-[0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]
port
OSRP line OSRPLINE OSRPLIN
AID (6500- -shelf- E-[0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]
port
OSRP line OSRPLINE OSRPLIN
AID (6500- -shelf- E-[0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]
port
ovpn-id INT Optical Virtual Private This parameter is only
(0-255) Network ID. applicable to OTN.
prot-bundle-ids INT List of up to 20 Grouping (&) is
(0-65535) protection bundles to supported. Specifies a
which the OSRP link list of bundle IDs in the
belongs. following format: <id>&
<id>&... Where id is a
value from 0 to 65535.
A value of 0 means
that the OSRP link
does not belong to any
protection bundle.
AID Descriptions
AID Type Format Values
OSRP remote links AID OSRPRMTLINKS-shelf-id OSRPRMTLINKS-[0..992]-[1]
Photonic OSRP remote OSRPRMTLINKS0-shelf-id OSRPRMTLINKS0-[0..992]-[1]
links AID
All remote Photonic OSRP OSRPRMTLINKS0-shelf-ALL OSRPRMTLINKS0-[0..992]-ALL
links on shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbrfilter string Specifies OSRP link Values: <node name>
( min len=1 max len=64 ) retrieval filter values.
Syntax Definition
Parameter Attributes Description Notes
aid M aid
adm-weight M Administrative weight It is also referred to as
which specifies the link usage cost. The
level of importance OSRP links with the
given to the OSRP lowest weight are
link. preferred during route
computation for SNCs
that are minimized by
weight.
direction M The direction, with This parameter is not
respect to the applicable to OTN.
advertising node,
where the parameters
in the metrics apply.
hstate M State of the Hello
protocol finite state
machine.
label M Label of the OSRP
link.
linkmaxdelay O Indicates the worst This parameter is only
delay in microseconds applicable to OTN.
of any OSRP line
aggregated in the link.
orig-link-id M ID of the link from the Value is 1 to 2048 for
origination node. SONET/SDH and
OTN, and 1 to 25438
for photonics.
orig-node-id M Node ID of the Format: Hexadecimal
originating node. (22 bytes) / String (44
chars).
orig-node-name M Name of the Maximum of 20
originating node. characters for
photonics.
ovpnid O Optical Virtual Private This parameter is only
Network ID. applicable to OTN.
pbids M L List of up to 20 Grouping (&) is
protection bundles to supported. Specifies a
which the OSRP link list of bundle IDs in the
belongs. following format: <id>&
<id>&... Where id is a
value from 0 to 65535.
A value of 0 means
that the OSRP link
does not belong to any
protection bundle.
remote-adm-weight O Administrative weight
associated with this
OSRP link's remote
side.
remote-label O Label of the remote
link.
remote-link-id O ID of the remote link. Value is 1 to 2048 for
SONET/SDH, 1 to
4194303 for OTN, and
1 to 25438 for
photonics.
remote-link-max-delay O The max delay This parameter is only
associated with the applicable to OTN.
remote OSRP link.
remote-node-id O Node ID of the remote Format: Hexadecimal
link. (22 bytes) / String (44
chars). This parameter
is only applicable to
OTN.
remote-node-name O Name of the remote Maximum of 20
node. characters for
photonics.
remote-ovpn-id O The Optical Virtual This parameter is only
Private Network ID of applicable to OTN.
the remote end.
remote-prot-bundle-ids O L List of up to 20 Grouping (&) is
protection bundles to supported. Specifies a
which the OSRP link list of bundle IDs in the
remote side belongs. following format: <id>&
<id>&... Where id is a
value from 0 to 65535.
A value of 0 means
that the OSRP link
does not belong to any
protection bundle.
AID Descriptions
AID Type Format Values
OSRP remote links AID OSRPRMTLINKS-shelf-id OSRPRMTLINKS-[0..992]-[1]
Photonic OSRP remote OSRPRMTLINKS0-shelf-id OSRPRMTLINKS0-[0..992]-[1]
links AID
All remote Photonic OSRP OSRPRMTLINKS0-shelf-ALL OSRPRMTLINKS0-[0..992]-ALL
links on shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbrfilter string Specifies OSRP link Values: <node name>
( min len=1 max len=64 ) retrieval filter values.
Syntax Definition
Parameter Attributes Description Notes
aid M aid
adm-weight M Administrative weight It is also referred to as
which specifies the link usage cost. The
level of importance OSRP links with the
given to the OSRP lowest weight are
link. preferred during route
computation for SNCs
that are minimized by
weight.
adv-bw M The link's advertised Format is a quoted
bandwidth (available, string with the
advertised, and following format for
maximum bandwidth) OTN:
for Normal usage. "advBw:maxBw:bwTyp
e" and with the
following format for the
SONET/SDH and
Photonics:
"avBw:maxBw:bwType
". 'bwType' is the
bandwidth type being
specified in 'avBw',
'maxBw', and if
applicable in 'advBw'.
For SONET/SDH,
'bwType' is STS1. For
OTN, 'bwType' is
ODU. For photonics,
'bwType' is OCH.
'avBw' indicates the
number of currently
available
STS1s/ODUs/OCHs
and available Bps for
ODUFlex. 'maxBw'
indicates the total
number of
STS1s/ODUs/OCHs
the OSRP link can
support. 'advBw' is
minimum of {Available
Bandwidth, Threshold
Bandwidth} for a
bandwidth type (for
ODUFlex is Bps).
adv-wl O A hexadecimal number Each bit set within the
which represents the number indicates
current wavelength which wavelength is
availability associated currently available.
with the OSRP link. The number of digits
provided varies
depending on the grid
type: 11 digits for grid
type C100G44, 22
digits for grid type
C50G88, 24 digits for
grid type C50G96 and
192 digits for grid type
CFLEX768. This
parameter is only
applicable to
photonics.
grid-type O Grid type of the OSRP This parameter is only
link. applicable to
photonics.
orig-link-id M ID of the link from the Value is 1 to 2048 for
origination node. SONET/SDH and
OTN, and 1 to 25438
for photonics.
orig-node-name M Name of the Maximum of 20
originating node. characters for
photonics.
remote-adm-weight O Administrative weight
associated with this
OSRP link's remote
side.
remote-prot-type O Protection types This parameter is only
supported for this applicable to OTN.
service class' OSRP
link from remote side.
rhp-adv-bw O The link's advertised Format is a quoted
bandwidth (advertised, string with the
and maximum following format:
bandwidth) for RHP "advBw:maxBw:bwTyp
usage. e". 'bwType' is the
bandwidth type being
specified in 'advBw'
and 'maxBw'. 'maxBw'
indicates the total
number of ODUs the
OSRP link can support
and 'advBw' is
minimum of {Available
Bandwidth, Threshold
Bandwidth} for a
bandwidth type. This
parameter is only
applicable to OTN.
sup-prot-type M Protection types APS is only applicable
supported for this to SONET/SDH.
service class.
transfer-delay O Indicates the worst This parameter is only
delay in microseconds applicable to OTN.
of any OSRP line
aggregated in the
remote link.
Output Parameter Description
Parameter Value Description Notes
aid ident aid
adm-weight INT Administrative weight It is also referred to as
(1-65535) which specifies the link usage cost. The
level of importance OSRP links with the
given to the OSRP lowest weight are
link. preferred during route
computation for SNCs
that are minimized by
weight.
adv-bw string The link's advertised Format is a quoted
( min len=1 max len=512 ) bandwidth (available, string with the
advertised, and following format for
maximum bandwidth) OTN:
for Normal usage. "advBw:maxBw:bwTyp
e" and with the
following format for the
SONET/SDH and
Photonics:
"avBw:maxBw:bwType
". 'bwType' is the
bandwidth type being
specified in 'avBw',
'maxBw', and if
applicable in 'advBw'.
For SONET/SDH,
'bwType' is STS1. For
OTN, 'bwType' is
ODU. For photonics,
'bwType' is OCH.
'avBw' indicates the
number of currently
available
STS1s/ODUs/OCHs
and available Bps for
ODUFlex. 'maxBw'
indicates the total
number of
STS1s/ODUs/OCHs
the OSRP link can
support. 'advBw' is
minimum of {Available
Bandwidth, Threshold
Bandwidth} for a
bandwidth type (for
ODUFlex is Bps).
adv-wl string A hexadecimal number Each bit set within the
( min len=11 max len=192 ) which represents the number indicates
current wavelength which wavelength is
availability associated currently available.
with the OSRP link. The number of digits
provided varies
depending on the grid
type: 11 digits for grid
type C100G44, 22
digits for grid type
C50G88, 24 digits for
grid type C50G96 and
192 digits for grid type
CFLEX768. This
parameter is only
applicable to
photonics.
grid-type C100G44, C50G88, C50G96, Grid type of the OSRP This parameter is only
CFLEX768, LFLEX744 link. applicable to
photonics.
orig-link-id INT ID of the link from the Value is 1 to 2048 for
(1-25438) origination node. SONET/SDH and
OTN, and 1 to 25438
for photonics.
orig-node-name string Name of the Maximum of 20
( min len=1 max len=40 ) originating node. characters for
photonics.
remote-adm-weight INT Administrative weight
(1-65535) associated with this
OSRP link's remote
side.
remote-prot-type UNPROTECTED, APS Protection types This parameter is only
supported for this applicable to OTN.
service class' OSRP
link from remote side.
rhp-adv-bw string The link's advertised Format is a quoted
( min len=1 max len=512 ) bandwidth (advertised, string with the
and maximum following format:
bandwidth) for RHP "advBw:maxBw:bwTyp
usage. e". 'bwType' is the
bandwidth type being
specified in 'advBw'
and 'maxBw'. 'maxBw'
indicates the total
number of ODUs the
OSRP link can support
and 'advBw' is
minimum of {Available
Bandwidth, Threshold
Bandwidth} for a
bandwidth type. This
parameter is only
applicable to OTN.
sup-prot-type UNPROTECTED, APS Protection types APS is only applicable
supported for this to SONET/SDH.
service class.
transfer-delay INT Indicates the worst This parameter is only
(0-200000) delay in microseconds applicable to OTN.
of any OSRP line
aggregated in the
remote link.
AID Descriptions
AID Type Format Values
DTL AID DTL-shelf-id DTL-[0..992]-[1..4096]
Photonic DTL AID DTL0-shelf-id DTL0-[0..992]-[1..8192]
No DTL NONE-shelf NONE-[0..992]
Input Parameter Description
Parameter Value Description Notes
assoc-fail-hop string The associated hop Format is a quoted
( min len=3 max len=45 ) whose failure should string with the
trigger the use of the following format:
DTLDATA. "nodeName,linkId",
where nodeName is
the OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), or spaces
are in the name, e.g.
\"My Node\").
nodeName can be 1 to
40 characters for
SONET/SDH and
OTN, and 1 to 20
characters for
photonics. linkId is a
value 1 to 2048 for
SONET/SDH and
OTN, and 1 to 25438
for photonics. Default:
Empty string.
dtl-ccmode MODE1, MODE2, MODE3 Specifies the capacity Setting this to MODE1,
change MODE2 and MODE3;
modes(MODE1- MODE1 will be the
Parallel add mode, default value for this
MODE2- Accelerated parameter
mode and MODE3-
Dead Reckoning
mode) of this DTL.
dtl-data string List of OSRP hops. User must provide at
( min len=3 max len=1139 ) least one hop. Format
is a quoted string
containing a list of up
to 40 hops with the
following format: "
<hop1>[&<hop2>][&
<hop3>]..[&<hop40>]".
Each hop has a format
of: nodeName,linkId[,
<lineId>,<timeslot>].
nodeName is the
OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), spaces,
colons(:), or
ampersands (&) are in
the name, e.g. \"My
Node\"). nodeName
can be 1 to 40
characters for
SONET/SDH and
OTN, and 1 to 20
characters for
photonics. linkId is a
value 1 to 2048 for
SONET/SDH and
OTN, and 1 to 25438
for photonics. lineId
represents the
common identifier
(CMNID) of the line
with a value 0 to
65534. timeslot is a
value 1 to 192. lineId
and timeslot are only
applicable to
SONET/SDH.
dtl-type NONE, MANUAL_SWITCH Specifies the purpose Setting this to
of this DTL during MANUAL_SWITCH
mesh restoration or makes the DTL usable
manual switch for manual switch
operations of an SNC. operations.
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
label string Label for the DTL.
( min len=0 max len=64 )
max-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) upper bound (in THz) Photonics.
min-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) lower bound (in THz) Photonics.
term-node-name string The OSRP node name Maximum of 20
( min len=1 max len=40 ) of the terminating node characters for
in the DTL. photonics.
txinfo-data string List of transponder To provision user must
( min len=5 max len=176 ) characteristics(ADJ- provide ADJ-shelf-slot,
shelf-slot- TransMode,
port,Transmission Frequency,
mode, Frequency, DispersionMin,
Minimum Dispersion, DispersionMax,
Maximum Dispersion, GuardBandLeft,
Lower GuardBand, GuardBandRight,
Higher GuardBand, ExpressTime and LOM
Expected Restoration entries. Format is a
Time, Link quoted string
Optimization Mode) for containing a list of
this DTL. Where ADJ-shelf-slot,
format and size of TransMode,
each fields are: ADJ- Frequency,
shelf-slot-port would DispersionMin,
be string of characters DispersionMax,
and its maximum size GuardBandLeft,
is 14 characters, GuardBandRight,
Transmission mode ExpressTime and LOM
would be string of in the following format:
integers and its size is "{<ADJ>,
2 characters(range 0- <TRANSMODE> ,
99), Frequency would <FREQUENCY> ,
be string of intergers <DISPERSION_MIN>
and its size is 9 ,
characters (range <DISPERSION_MAX>
186.325000- ,
190.975000, <GUARDBAND_LEFT
191.325000- >,
196.125000), Minimum <GUARDBAND_RIGH
Dispersion would be T> ,
string of integers and <EXPRESS_TIME> ,
its maximum size is 5 <LOM>}&{<ADJ> ,
characters(range (- <TRANSMODE> ,
)99999-99999), <FREQUENCY> ,
Maximum Dispersion <DISPERSION_MIN>
would be string of ,
integers and its <DISPERSION_MAX>
maximum size is 5 ,
characters(range (- <GUARDBAND_LEFT
)99999-99999), Lower >,
GuardBand would be <GUARDBAND_RIGH
string of integers and T> ,
its maximum size is 8 <EXPRESS_TIME> ,
characters(range 0- <LOM>}....{<ADJ> ,
4800.000), Higher <TRANSMODE> ,
GuardBand would be <FREQUENCY> ,
string of integers and <DISPERSION_MIN>
its maximum size is 8 ,
characters(range 0- <DISPERSION_MAX>
4800.000), Expected ,
Restoration Time <GUARDBAND_LEFT
would be string of >,
integers and its <GUARDBAND_RIGH
maximum size is 3 T> ,
characters(range 0- <EXPRESS_TIME> ,
100 seconds), Link <LOM>}". Each ADJ-
Optimization Mode TX entry has a format
would be string of of: ADJ-shelf-slot,
integers and its TransMode,
maximum size is 2 Frequency,
characters (range 0- DispersionMin,
99) DispersionMax,
GuardBandLeft,
GuardBandRight,
ExpressTime, LOM
wvl-grid string A hexadecimal number Each bit set within the
( min len=0 max len=96 ) representing the vector number indicates
of wavelengths that which wavelength is
can be used by currently configured.
connection on this Default WVLGRID is
DTL. all bits set. This
parameter is only
applicable to
photonics.
AID Descriptions
AID Type Format Values
DTL AID DTL-shelf-id DTL-[0..992]-[1..4096]
Photonic DTL AID DTL0-shelf-id DTL0-[0..992]-[1..8192]
Input Parameter Description
Parameter Value Description Notes
label string Label for the DTL.
( min len=0 max len=64 )
max-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) upper bound (in THz) Photonics.
min-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) lower bound (in THz) Photonics.
txinfo-data string List of transponder To provision user must
( min len=5 max len=176 ) characteristics(ADJ- provide ADJ-shelf-slot,
shelf-slot- TransMode,
port,Transmission Frequency,
mode, Frequency, DispersionMin,
Minimum Dispersion, DispersionMax,
Maximum Dispersion, GuardBandLeft,
Lower GuardBand, GuardBandRight,
Higher GuardBand, ExpressTime and LOM
Expected Restoration entries. Format is a
Time, Link quoted string
Optimization Mode) for containing a list of
this DTL. Where ADJ-shelf-slot,
format and size of TransMode,
each fields are: ADJ- Frequency,
shelf-slot-port would DispersionMin,
be string of characters DispersionMax,
and its maximun size GuardBandLeft,
is 14 characters, GuardBandRight,
Transmission mode ExpressTime and LOM
would be string of in the following format:
integers and its size is "{<ADJ>,
2 characters(range 0- <TRANSMODE> ,
99), Frequency would <FREQUENCY> ,
be string of intergers <DISPERSION_MIN>
and its size is 9 ,
characters (range <DISPERSION_MAX>
186.325000- ,
190.975000, <GUARDBAND_LEFT
191.325000- >,
196.125000), Minimum <GUARDBAND_RIGH
Dispersion would be T> ,
string of integers and <EXPRESS_TIME> ,
its maximum size is 5 <LOM>}&{<ADJ> ,
characters(range (- <TRANSMODE> ,
)99999-99999), <FREQUENCY> ,
Maximum Dispersion <DISPERSION_MIN>
would be string of ,
integers and its <DISPERSION_MAX>
maximum size is 5 ,
characters(range (- <GUARDBAND_LEFT
)99999-99999), Lower >,
GuardBand would be <GUARDBAND_RIGH
string of integers and T> ,
its maximum size is 8 <EXPRESS_TIME> ,
characters(range 0- <LOM>}....{<ADJ> ,
4800.000), Higher <TRANSMODE> ,
GuardBand would be <FREQUENCY> ,
string of integers and <DISPERSION_MIN>
its maximum size is 8 ,
characters(range 0- <DISPERSION_MAX>
4800.000), Expected ,
Restoration Time <GUARDBAND_LEFT
would be string of >,
integers and its <GUARDBAND_RIGH
maximum size is 3 T> ,
characters(range 0- <EXPRESS_TIME> ,
100 seconds), Link <LOM>}". Each ADJ-
Optimization Mode TX entry has a format
would be string of of: ADJ-shelf-slot,
integers and its TransMode,
maximum size is 2 Frequency,
characters (range 0- DispersionMin,
99). DispersionMax,
GuardBandLeft,
GuardBandRight,
ExpressTime, LOM
AID Descriptions
AID Type Format Values
Cascaded DTL AID CASCDTL0-shelf-id CASCDTL0-[0..992]-[1..8192]
Input Parameter Description
Parameter Value Description Notes
label string Label for the
( min len=0 max len=64 ) CASCDTL.
AID Descriptions
AID Type Format Values
DTL set AID DTLSET-shelf-id DTLSET-[0..992]-[1..1024]
Photonic DTL set AID DTLSET0-shelf-id DTLSET0-[0..992]-[1..1024]
No DTL set NONE-shelf NONE-[0..992]
Input Parameter Description
Parameter Value Description Notes
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
label string Label for the DTLSET.
( min len=0 max len=64 )
prot-dtls DTL AID DTL- DTL- Specifies the The protection DTL or
shelf-id [0..992]- protection DTL or CASCDTL list
[1..4096] CASCDTL list. parameter specifies
Photonic DTL0- DTL0- existing DTLs or
DTL AID shelf-id [0..992]- CASCDTLs to be used
[1..8192] as protection DTLs in
Cascaded CASCDTL0 CASCDTL this DTLSET.
DTL AID -shelf- 0-[0..992]- CASCDTL is only
[1..8192] applicable to
id photonics. Grouping
No DTL NONE- NONE- (&) is supported. Each
shelf [0..992] DTLSET can have 0 to
20 protection routes.
Default: NONE-
<shelf>. Format: DTL-
<shelf>-
<id>&CASCDTL-
<shelf>-<id>&DTL-
<shelf>-<id>&...
wrk-dtl DTL AID DTL- DTL- Working DTL or Format: DTL AID or
shelf-id [0..992]- CASCDTL route for CASCDTL AID.
[1..4096] this DTLSET. CASCDTL AID is only
Photonic DTL0- DTL0- applicable to
DTL AID shelf-id [0..992]- photonics.
[1..8192]
Cascaded CASCDTL0 CASCDTL
DTL AID -shelf- 0-[0..992]-
id [1..8192]
AID Descriptions
AID Type Format Values
No non-viable DTL set NONE-shelf NONE-[0..992]
Input Parameter Description
Parameter Value Description Notes
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
label string Label for the non-
( min len=0 max len=64 ) viable DTL set.
nv-dtls Photonic DTL0- DTL0- Specifies a list of non- The NVDTLS
DTL AID shelf-id [0..992]- viable DTLs. parameter specifies
[1..8192] existing DTLs to be
used in this non-viable
DTL set. Grouping (&)
is supported. There
can be 1 to 20 DTLs.
Format: DTL-<shelf>-
<id>&DTL-<shelf>-
<id>&...
AID Descriptions
AID Type Format Values
Originating SNC AID SNC-shelf-id SNC-[0..992]-[1..1024]
Originating Photonic SNC SNC0-shelf-id SNC0-[0..992]-[1..1024]
AID
Input Parameter Description
Parameter Value Description Notes
absol-route-diversity ON, OFF Indicates if Absolute Can only be set to ON
Route Diversity (ARD) for MR-SNCPs.
is enabled.
backoff-period INT Back-off period for Default is 2 seconds
(1-30) retrying SNC setup (in for photonics, and 1
seconds). second for
SONET/SDH and
OTN. The back-off
period doubles for
each subsequent retry
up to 30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
bit-rate string Define the bit rate of This parameter is only
( min len=0 max len=19 ) flex. applicable to OTN.
ccmode DTLMODE, MODE1, MODE2, Specify the capacity In case MCCTTP
MODE3 change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
cost-crit-admin-weight MANDATORY
BESTEFFORT
DISABLE
cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
cost-criteria DELAY
ADMINWEIGHT
datapath-fault-action MR, ALARM Indicates whether an This parameter is
ALARM will be raised aplicable to L0
or MR will be done on Photonics only. Default
SNC Datapath is ALARM
Fault.Default is
ALARM
datapath-fault-alm-time INT Specifies in minutes A value of 0 specifies
(0-30 Default=15) how long to wait before that the alarm is never
raising the SNC to be raised.
datapath fault alarm. Otherwise, a value of 5
to 30 minutes can be
specified. This
parameter is only
applicable to
photonics.
dtl-excl NO
YES
DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used for Format: DTLSET AID
AID shelf-id [0..992]- this SNC. or NONE-<shelf>.
[1..1024] Default: NONE-
Photonic DTLSET0- DTLSET0- <shelf>. For Photonics
DTL set shelf-id [0..992]- this is a mandatory in
AID [1..1024] R11.6 if
No DTL NONE- NONE- GROUPED=NO
set shelf [0..992]
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
end-pt-size STS1
STS3C
STS12C
STS24C
STS48C
STS192C
ODU0
ODU1
ODU2
ODU2E
ODU3
ODU4
ODUFLEX
frequency DECIMAL Specifies the explicit This parameter is only
(0.000000, 186.325000- centre frequency to applicable to
190.975000, 191.325000- use for the service. Photonics.
196.125000) The value 0 (default)
means the system will
select the frequency.
All SNCs in an SNCG
must all be explicit or
all must be implicit
generic-end-point YES
NO
grouped YES
NO
home-path-preempt DISABLED
RESERVED
label string Label of this object. Default: Empty string.
( min len=0 max len=64 )
local-end-point string Local end-point of this Values: CTP AID, VCP
SNC. AID, VEP AID, ADJ
AID, OCH AID,
OSRPLAG AID, or
SONET Payload AID.
max-adm-weight INT SONET/SDH and
(0-1310700 Default=0) Photonics: Maximum
admin weight allowed
for this connection.
OTN: Maximum admin
weight allowed for the
home path.
max-delay INT Maximum delay This parameter is only
(0-4000000 Default=0) allowed for the home applicable to OTN.
path (in
microseconds).
max-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) upper bound (in THz) Photonics.
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNC.
for this SNC.
min-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) lower bound (in THz) Photonics.
mode OTN, PKTRSRVD, PKTNORSRVD Specifies the SNC This parameter is only
mode applicable to OTN.
mrccmode DTLMODE, MODE1, MODE2, Specify the mesh In case MCCTTP
MODE3 restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
name string Name of this SNC. Supported for OTN
( min len=0 max len=40 ) only. Default: SNC AID
nv-dtl-set-name No non- NONE- NONE- Non-viable DTL set to Format: NVDTLSET
viable DTL shelf [0..992] be used for this SNC. AID or NONE-<shelf>.
set Default: NONE-
<shelf>. This
parameter is only
applicable to
photonics.
origin-drop-side-prot- HIGH_ORDER, UNPROTECTED Specifies drop side Defaults to
state protection state for the UNPROTECTED for
SNC on the originating SNCP. For
node. SONET/SDH and
photonics, only
UNPROTECTED is
applicable.
origin-net-side-prot- HIGH_ORDER, UNPROTECTED Specifies network side Defaults to
state protection state for the HIGH_ORDER for
SNC on the originating SNCP for
node. SONET/SDH and
OTN. For photonics,
only UNPROTECTED
is applicable.
peer-origin string The peer originating Only applicable to
( min len=1 max len=40 ) node name specifies SNCPs. Default: Local
the node name from node for SNCPs,
which the peer SNC empty string
originates. otherwise. Maximum
of 20 characters for
photonics.
peer-snc string Identifies the peered Having a peer
SNC on this local node indicates that this SNC
or on the node is part of an SNCP.
specified in parameter Format: SNC AID for
PEERORIGIN. 6500, SNC name for
CD/54xx. Default:
Undefined value.
primary-ovpn-ids string The primary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. This parameter
is only applicable to
OTN.
prot-cost-crit-adm- MANDATORY
weight BESTEFFORT
DISABLE
prot-cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
prot-max-adm-weight INT Maximum admin This parameter is only
(0-1310700 Default=0) weight allowed for the applicable to OTN.
protect path.
prot-max-delay INT Maximum delay This parameter is only
(0-4000000 Default=0) allowed for the protect applicable to OTN.
path.
prot-type APS_VLSR_PROTECTED
APS_VLSR_UNPROTECTED
UNPROTECTED
UNPROTECTED_HIGH
UNPROTECTED_LOW
UNPROTECTED_PROTECT
regroom ON, OFF Indicates if re-groom
operation can be
performed on this
SNC.
release-on-client-fail DISABLED, PORT, PAYLOAD Specifies the Release This parameter is only
on Client Failure applicable to OTN.
capability
release-on-client-fail- IMMEDIATE, ALARM Specifies the Release This parameter is only
holdoff on Client Failure hold applicable to OTN.
off
remote-ctp-path-term YES
NO
remote-end-point string Remote end-point of Values: OSRPLAG
this SNC. AID, VCP AID,
OTUTTP AID,
ODUTTP AID, ETTP
AID, STTP AID, FTTP
AID, VEP AID, ADJ
AID, OCH AID,
SONET Payload AID,
or the appropriate end-
point AID for a non-
6500 product
(CD/54xx).
remote-end-point-type CTP
VCP
VEP
GEP
OSRPLAG
remote-interop OTHER Interop with equipment
other than 2G5 MOTR
2G5MOTR Interop with equipment
2G5 MOTR
remote-node string Specifies the name of Maximum of 20
( min len=1 max len=40 ) the remote end node characters for
on which the SNC photonics.
terminates.
remote-path-protection NONE
HIGH_ORDER
LOW_ORDER
remote-time-slot string Timeslot to use when Specifies a list of
( min len=1 max len=192 ) creating the remote timeslots. Values for
end-point. each timeslot are from
1-32 for OTN and 1-
192 for SONET/SDH.
One of either grouping
or ranging is allowed.
When grouping or
ranging is used, the
values must be
specified within
quotes. Example
formats: "1&4&6" OR
"1&&5". This
parameter is not
applicable to
photonics.
remote-ttp-mux ODTU01_PT20
ODTU12_PT20
ODTU12_PT21
ODTU13_PT21
ODTU23_PT20
ODTU23_PT21
ODTU34_PT21
ODTU24_PT21
ODTU14_PT21
ODTUK_TS
OTUK
NONE
retain-home-path- YES
capability NO
revert-time INT Amount of time for a Not applicable when
(300-86400 Default=300) connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
revert-timer SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
secondary-ovpn-ids string The secondary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. NONE indicates
secondary OVPNID's
are not used. This
parameter is only
applicable to OTN.
snc-integrity-check ON, OFF Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
snc-line-type WORKING, PROTECT Identifiers if this SNC Mandatory for SNCPs.
is the working or Default: Undefined
protecting leg of an value.
SNCP.
takeover YES, NO Specifies if cross- This parameter is
connection takeover is applicable to
to be performed by the SONET/SDH and
SNC. photonics.This
parameter is not
applicable to OTN.
tcm INT Override the system Default: System
(0-6) default SNC TCM. default. TCM value of
0 disables TCM. This
parameter is only
applicable to OTN.
termin-drop-side-prot- HIGH_ORDER, UNPROTECTED Specifies drop side Defaults to
state protection state for the UNPROTECTED for
SNC on the SNCP. For photonics,
terminating node. only UNPROTECTED
is applicable.
termin-net-side-prot- HIGH_ORDER, UNPROTECTED Specifies network side Defaults to
state protection state for the HIGH_ORDER for
SNC on the SNCP for
terminating node. SONET/SDH and
OTN. For photonics,
only UNPROTECTED
is applicable.
tod-revert-holdback- YES
enabled NO
tod-revert-holdback- time Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-period INT Specifies the time Mandatory if TODR is
(5-300) range (in minutes) set. This parameter is
when it's acceptable to only applicable to
do the TODR (home OTN.
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-prof-list Time of TODRPROF TODRPRO List of time of day Grouping (&) is
Day -shelf- F-[0..992]- reversion profiles that supported. This
Reversion id [1..100] are associated with parameter specifies a
Profile AID this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
tod-revert-time time Specifies the time of Format is HH-MM, i.e.
day when to do 02-05 or 22-59. Range
reversion to the home is 00-00 to 23-59. This
path (home path must parameter is only
be available). applicable to OTN.
tolerance string Define the tolerance in It is used for
( min len=0 max len=19 ) ppm of oduflex before ODUFLEX
an LOF is declared.
trib-port INT Tributary port for This parameter is only
(0-32 Default=0) creating line side CTPs applicable to OTN.
type DYNAMIC
PERM
validate YES
NO
wvl-grid string A hexadecimal number Each bit set within the
( min len=0 max len=96 ) representing the vector number indicates
of wavelengths that which wavelength is
can be used by this currently configured.
SNC. Default WVLGRID is
all bits set. This
parameter is only
applicable to
photonics.
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
Top of OSRP Section
osrp snc set
Description: Edit a Subnetwork Connection.
CLI command: osrp snc set
Security Level: 3
Input syntax osrp snc set <aid> [absol-route-diversity <Value>][backoff-period
<Value>][bit-rate <Value>][ccmode <Value>][cost-crit-admin-weight
<Value>][cost-crit-delay <Value>][cost-criteria <Value>][datapath-
fault-action <Value>][datapath-fault-alm-time <Value>][dtl-excl
<Value>][dtl-set-name <Value>][frequency <Value>][generic-end-point
<Value>][grouped <Value>][home-path-preempt <Value>][label <Value>]
[local-end-point <Value>][make-home-path <Value>][max-adm-weight
<Value>][max-delay <Value>][max-freq <Value>][mesh-rest <Value>][min-
freq <Value>][mode <Value>][mrccmode <Value>][nv-dtl-set-name <Value>]
[primary-ovpn-ids <Value>][prot-cost-crit-adm-weight <Value>][prot-
cost-crit-delay <Value>][prot-max-adm-weight <Value>][prot-max-delay
<Value>][prot-type <Value>][regroom <Value>][release-on-client-fail
<Value>][release-on-client-fail-holdoff <Value>][remote-ctp-path-
term <Value>][remote-end-point <Value>][remote-end-point-type
<Value>][remote-node <Value>][remote-time-slot <Value>][remote-ttp-
mux <Value>][resize-bitrate <Value>][retain-home-path-capability
<Value>][revert-time <Value>][revert-timer <Value>][route-operation
<Value>][secondary-ovpn-ids <Value>][snc-integrity-check <Value>]
[takeover <Value>][tcm <Value>][tod-revert-holdback-enabled <Value>]
[tod-revert-holdback-period <Value>][tod-revert-period <Value>][tod-
revert-prof-list <Value>][tod-revert-time <Value>][tolerance <Value>]
[trib-port <Value>][type <Value>][wvl-grid <Value>]
Syntax Definition
Parameter Attributes Description Notes
absol-route-diversity O Indicates if Absolute Can only be set to ON
Route Diversity (ARD) for MR-SNCPs.
is enabled.
backoff-period O Back-off period for The back-off period
retrying SNC setup (in doubles for each
seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
bit-rate O Define the bit rate of Can only edit if
flex. RTEOPR is set to
RESIZE. This
parameter is only
applicable to OTN.
ccmode O Specify the capacity In case MCCTTP
change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
cost-crit-admin-weight O The cost criteria This parameter is only
setting for admin applicable to OTN.
weight.
cost-crit-delay O The cost criteria This parameter is only
setting for delay of the applicable to OTN.
home path.
cost-criteria O The cost criteria Supported for OTN
applicable for this only.
connection. This is
applicable for the
originating end SNC
only.
datapath-fault-action O Indicates whether an This parameter is
ALARM will be raised aplicable to L0
or MR will be done on Photonics only. Default
SNC Datapath is ALARM
Fault.Default is
ALARM
datapath-fault-alm-time O Specifies in minutes A value of 0 specifies
how long to wait beforethat the alarm is never
raising the SNC to be raised.
datapath fault alarm. Otherwise, a value of 5
to 30 minutes can be
specified. This
parameter is only
applicable to
photonics.
dtl-excl O Specifies whether to For SONET/SDH and
exclusively use the photonics, YES
DTL set specified by indicates the DTL list
DTLSN. specified in the
DTLSET shall
exclusively be used
and NO indicates the
DTL list specified in
the DTLSET shall
preferably be used.
For OTN, the values
DISABLE, WORKING,
WORKINGPROTECT
and PREFERRED are
used.
dtl-set-name O DTL set to be used for Format: DTLSET AID
this SNC. or NONE-<shelf>.
NONE-<shelf> is not
applicable to
photonics.
frequency O Specifies the explicit This parameter is only
centre frequency to applicable to
use for the service(in Photonics.
THz). The value 0
(default) means the
system will select the
frequency. All SNCs in
an SNCG must all be
explicit or all must be
implicit.
generic-end-point O Specifies whether This parameter is only
Generic End Point applicable to OTN.
(GEP) method is
allowed.
grouped O Specifies, Is SNC of This parameter is only
SNCG. It is an optional applicable to
attribute and Default Photonics.
value would be NO.
value =YES/NO
home-path-preempt O Specifies the Home This parameter is only
Path Preempt applicable to OTN.
capability definition.
label O Label of this object.
local-end-point O Local end-point of this Values: CTP AID, VCP
SNC. AID, VEP AID, ADJ
AID, OCH AID,
OSRPLAG AID, or
SONET Payload AID.
make-home-path O Will be used along with This parameter is only
RTEOPR to change applicable to OTN.
the current path to
home path.
max-adm-weight O SONET/SDH and
Photonics: Maximum
admin weight allowed
for this connection.
OTN: Maximum admin
weight allowed for the
home path.
max-delay O Maximum delay This parameter is only
allowed for the home applicable to OTN.
path (in
microseconds).
max-freq O R Constrain the This parameter is only
frequency allocated applicable to
upper bound (in THz) Photonics.
mesh-rest O Indicates if mesh- Always OFF for P-
restoration is enabled SNC.
for this SNC.
min-freq O R Constrain the This parameter is only
frequency allocated applicable to
lower bound (in THz) Photonics.
mode O Specifies the SNC Can only edit mode
mode between PKTRSRVD
and PKTNORSRVD.
This parameter is only
applicable to OTN.
mrccmode O Specify the mesh In case MCCTTP
restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
nv-dtl-set-name O Non-viable DTL set to Format: NVDTLSET
be used for this SNC. AID or NONE-<shelf>.
This parameter is only
applicable to
photonics.
primary-ovpn-ids O L The primary optical Supports up to 4 ID's
virtual private network in an ampersand
ID list delimited quoted
string. This parameter
is only applicable to
OTN.
prot-cost-crit-adm- O The protect cost This parameter is only
weight criteria admin weight applicable to OTN.
setting.
prot-cost-crit-delay O The protect cost This parameter is only
criteria delay setting. applicable to OTN.
prot-max-adm-weight O Maximum admin This parameter is only
weight allowed for the applicable to OTN.
protect path.
prot-max-delay O Maximum delay This parameter is only
allowed for the protect applicable to OTN.
path.
prot-type O The protection type OTN and photonics
parameter indicates only supports
the service class of UNPROTECTED_HIG
protection for the SNC. H and
UNPROTECTED_LO
W. SONET/SDH only
supports,
APS_VLSR_PROTEC
TED,
APS_VLSR_UNPROT
ECTED,
UNPROTECTED, and
UNPROTECTED_PR
OTECT.
regroom O Indicates if re-groom
operation can be
performed on this
SNC.
release-on-client-fail O Specifies the Release This parameter is only
on Client Failure applicable to OTN.
capability
release-on-client-fail- O Specifies the Release This parameter is only
holdoff on Client Failure hold applicable to OTN.
off
remote-ctp-path-term O Determines whether Valid for OTN only.
remote CTP is path
terminating or not
remote-end-point O Remote end-point of Values: OSRPLAG
this SNC. AID, VCP AID,
OTUTTP AID,
ODUTTP AID, ETTP
AID, STTP AID, FTTP
AID, VEP AID, ADJ
AID, OCH AID,
SONET Payload AID,
or the appropriate end-
point AID for a non-
6500 product
(CD/54xx).
remote-end-point-type O Indicates the type of This parameter is not
end-point. applicable to
photonics. Default
value is CTP for
SONET Payload AIDs,
CTP for CD/54xx port
AIDs, and VEP for
VEP AIDs.
RMTEPTYPE must be
specified when
RMTEP specifies a
CD/54xx VCP or a
generic endpoint. OTN
does not support VEP.
This parameter is
mandatory for OTN if
RMTEP is specified.
remote-node O Specifies the name of Maximum of 20
the remote end node characters for
on which the SNC photonics.
terminates.
remote-time-slot O Timeslot to use when Specifies a list of
creating the remote timeslots. Values for
end-point. each timeslot are from
1-32 for OTN and 1-
192 for SONET/SDH.
One of either grouping
or ranging is allowed.
When grouping or
ranging is used, the
values must be
specified within
quotes. Example
formats: "1&4&6" OR
"1&&5". This
parameter is not
applicable to
photonics.
remote-ttp-mux O Describes the Valid for OTN only.
multiplex structure and
payload type for the far
end TTP in
accordance with ITU-T
G.709
resize-bitrate O Specifies the Can edit only if
regroomed bitrate in RTEOPER is set to
bits per second (bps). REGROOM. This
parameter is only
applicable to OTN.
retain-home-path- O Specifies if the Retain Retain Home Path
capability Home Path capability provides the
is available. functionality of
retaining to the home
path and also updating
the current path to the
home path if needed.
This parameter is only
applicable to OTN.
revert-time O Amount of time for a Not applicable when
connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
revert-timer O Specifies whether the A value of
connection is to revert SNC_DELAY is only
to the original route applicable when
after a delay MESHRST is set to
(SNC_DELAY), the ON.
connection is not to SNC_TIMEOFDAY is
revert to the original only applicable to
route OTN.
(SNC_NO_REVERT),
or if the connection is
to revert at a certain
time(SNC_TIMEOFDA
Y).
route-operation O Specifies the SNC Specifies whether the
route operation. SNC performs a
protection switch
(MANSWITCH),
recalculates the home
DTL (REGROOM) or
reverts to the home
DTL (REVERT).
secondary-ovpn-ids O The secondary optical Supports up to 4 ID's
virtual private network in an ampersand
ID list delimited quoted
string. NONE indicates
secondary OVPNID's
are not used. This
parameter is only
applicable to OTN.
snc-integrity-check O Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
takeover O Indicates if the cross- This parameter is
connection takeover applicable to
specification value is toSONET/SDH and
be cleared for this photonics.This
SNC. parameter is not
applicable to OTN.
tcm O Override the system TCM value of 0
default SNC TCM. disables TCM. This
parameter is only
applicable to OTN.
tod-revert-holdback- O Specifies if time of day Default value is YES.
enabled reversion holdback is This parameter is only
enabled. applicable to OTN.
tod-revert-holdback- O Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-period O Specifies the time Mandatory if TODR is
range (in minutes) set. This parameter is
when it's acceptable to only applicable to
do the TODR (home OTN.
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-prof-list O L List of time of day Grouping (&) is
reversion profiles that supported. This
are associated with parameter specifies a
this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
tod-revert-time O Specifies the time of Format is HH:MM, i.e.
day when to do 02:05, or 22:59.
reversion to the home Default value is 02:00.
path (home path must This parameter is only
be available). applicable to OTN.
tolerance O Define the tolerance in It is used for
ppm of oduflex before ODUFLEX
an LOF is declared.
trib-port O Tributary port for This parameter is only
creating line side CTPs applicable to OTN.
type O Type of this SNC, This parameter is only
dynamic or permanent. applicable to OTN.
wvl-grid O A hexadecimal number Each bit set within the
representing the vector number indicates
of wavelengths that which wavelength is
can be used by this currently configured.
SNC. Default WVLGRID is
all bits set. This
parameter is only
applicable to
photonics.
AID Descriptions
AID Type Format Values
Originating SNC AID SNC-shelf-id SNC-[0..992]-[1..1024]
Originating Photonic SNC SNC0-shelf-id SNC0-[0..992]-[1..1024]
AID
Input Parameter Description
Parameter Value Description Notes
absol-route-diversity ON, OFF Indicates if Absolute Can only be set to ON
Route Diversity (ARD) for MR-SNCPs.
is enabled.
backoff-period INT Back-off period for The back-off period
(1-30) retrying SNC setup (in doubles for each
seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
bit-rate string Define the bit rate of Can only edit if
( min len=0 max len=19 ) flex. RTEOPR is set to
RESIZE. This
parameter is only
applicable to OTN.
ccmode DTLMODE, MODE1, MODE2, Specify the capacity In case MCCTTP
MODE3 change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
cost-crit-admin-weight MANDATORY
BESTEFFORT
DISABLE
cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
cost-criteria DELAY
ADMINWEIGHT
datapath-fault-action MR, ALARM Indicates whether an This parameter is
ALARM will be raised aplicable to L0
or MR will be done on Photonics only. Default
SNC Datapath is ALARM
Fault.Default is
ALARM
datapath-fault-alm-time INT Specifies in minutes A value of 0 specifies
(0-30) how long to wait before that the alarm is never
raising the SNC to be raised.
datapath fault alarm. Otherwise, a value of 5
to 30 minutes can be
specified. This
parameter is only
applicable to
photonics.
dtl-excl NO
YES
DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used for Format: DTLSET AID
AID shelf-id [0..992]- this SNC. or NONE-<shelf>.
[1..1024] NONE-<shelf> is not
Photonic DTLSET0- DTLSET0- applicable to
DTL set shelf-id [0..992]- photonics.
AID [1..1024]
No DTL NONE- NONE-
set shelf [0..992]
frequency DECIMAL Specifies the explicit This parameter is only
(0.000000, 186.325000- centre frequency to applicable to
190.975000, 191.325000- use for the service(in Photonics.
196.125000) THz). The value 0
(default) means the
system will select the
frequency. All SNCs in
an SNCG must all be
explicit or all must be
implicit.
generic-end-point YES
NO
grouped YES
NO
home-path-preempt DISABLED
RESERVED
label string Label of this object.
( min len=0 max len=64 )
local-end-point string Local end-point of this Values: CTP AID, VCP
SNC. AID, VEP AID, ADJ
AID, OCH AID,
OSRPLAG AID, or
SONET Payload AID.
make-home-path YES
NO
max-adm-weight INT SONET/SDH and
(0-1310700) Photonics: Maximum
admin weight allowed
for this connection.
OTN: Maximum admin
weight allowed for the
home path.
max-delay INT Maximum delay This parameter is only
(0-4000000) allowed for the home applicable to OTN.
path (in
microseconds).
max-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) upper bound (in THz) Photonics.
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNC.
for this SNC.
min-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) lower bound (in THz) Photonics.
mode PKTRSRVD, PKTNORSRVD Specifies the SNC Can only edit mode
mode between PKTRSRVD
and PKTNORSRVD.
This parameter is only
applicable to OTN.
mrccmode DTLMODE, MODE1, MODE2, Specify the mesh In case MCCTTP
MODE3 restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
nv-dtl-set-name No non- NONE- NONE- Non-viable DTL set to Format: NVDTLSET
viable DTL shelf [0..992] be used for this SNC. AID or NONE-<shelf>.
set This parameter is only
applicable to
photonics.
primary-ovpn-ids string The primary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. This parameter
is only applicable to
OTN.
prot-cost-crit-adm- MANDATORY
weight BESTEFFORT
DISABLE
prot-cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
prot-max-adm-weight INT Maximum admin This parameter is only
(0-1310700) weight allowed for the applicable to OTN.
protect path.
prot-max-delay INT Maximum delay This parameter is only
(0-4000000) allowed for the protect applicable to OTN.
path.
prot-type APS_VLSR_PROTECTED
APS_VLSR_UNPROTECTED
UNPROTECTED
UNPROTECTED_HIGH
UNPROTECTED_LOW
UNPROTECTED_PROTECT
regroom ON, OFF Indicates if re-groom
operation can be
performed on this
SNC.
release-on-client-fail DISABLED, PORT, PAYLOAD Specifies the Release This parameter is only
on Client Failure applicable to OTN.
capability
release-on-client-fail- IMMEDIATE, ALARM Specifies the Release This parameter is only
holdoff on Client Failure hold applicable to OTN.
off
remote-ctp-path-term YES
NO
remote-end-point string Remote end-point of Values: OSRPLAG
this SNC. AID, VCP AID,
OTUTTP AID,
ODUTTP AID, ETTP
AID, STTP AID, FTTP
AID, VEP AID, ADJ
AID, OCH AID,
SONET Payload AID,
or the appropriate end-
point AID for a non-
6500 product
(CD/54xx).
remote-end-point-type CTP
VCP
VEP
GEP
OSRPLAG
remote-node string Specifies the name of Maximum of 20
( min len=1 max len=40 ) the remote end node characters for
on which the SNC photonics.
terminates.
remote-time-slot string Timeslot to use when Specifies a list of
( min len=1 max len=192 ) creating the remote timeslots. Values for
end-point. each timeslot are from
1-32 for OTN and 1-
192 for SONET/SDH.
One of either grouping
or ranging is allowed.
When grouping or
ranging is used, the
values must be
specified within
quotes. Example
formats: "1&4&6" OR
"1&&5". This
parameter is not
applicable to
photonics.
remote-ttp-mux ODTU01_PT20
ODTU12_PT20
ODTU12_PT21
ODTU13_PT21
ODTU23_PT20
ODTU23_PT21
ODTU34_PT21
ODTU24_PT21
ODTU14_PT21
ODTUK_TS
OTUK
NONE
resize-bitrate string Specifies the Can edit only if
( min len=0 max len=19 ) regroomed bitrate in RTEOPER is set to
bits per second (bps). REGROOM. This
parameter is only
applicable to OTN.
retain-home-path- YES
capability NO
revert-time INT Amount of time for a Not applicable when
(300-86400) connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
revert-timer SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
route-operation MANSWITCH
REGROOM
RESIZE
REVERT
secondary-ovpn-ids string The secondary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. NONE indicates
secondary OVPNID's
are not used. This
parameter is only
applicable to OTN.
snc-integrity-check ON, OFF Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
takeover YES, NO This parameter is
Indicates if the cross-
connection takeover applicable to
SONET/SDH and
specification value is to
be cleared for this photonics.This
SNC. parameter is not
applicable to OTN.
tcm INT Override the system TCM value of 0
(0-6) default SNC TCM. disables TCM. This
parameter is only
applicable to OTN.
tod-revert-holdback- YES, NO Specifies if time of day Default value is YES.
enabled reversion holdback is This parameter is only
enabled. applicable to OTN.
tod-revert-holdback- time Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-period INT Specifies the time Mandatory if TODR is
(5-300) range (in minutes) set. This parameter is
when it's acceptable to only applicable to
do the TODR (home OTN.
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-prof-list Time of TODRPROF TODRPRO List of time of day Grouping (&) is
Day -shelf- F-[0..992]- reversion profiles that supported. This
Reversion id [1..100] are associated with parameter specifies a
Profile AID this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
tod-revert-time time Specifies the time of Format is HH:MM, i.e.
day when to do 02:05, or 22:59.
reversion to the home Default value is 02:00.
path (home path must This parameter is only
be available). applicable to OTN.
tolerance string Define the tolerance in It is used for
( min len=0 max len=19 ) ppm of oduflex before ODUFLEX
an LOF is declared.
trib-port INT Tributary port for This parameter is only
(0-32 Default=0) creating line side CTPs applicable to OTN.
type DYNAMIC
PERM
wvl-grid string A hexadecimal number Each bit set within the
( min len=0 max len=96 ) representing the vector number indicates
of wavelengths that which wavelength is
can be used by this currently configured.
SNC. Default WVLGRID is
all bits set. This
parameter is only
applicable to
photonics.
AID Descriptions
AID Type Format Values
Originating SNC AID SNC-shelf-id SNC-[0..992]-[1..1024]
Originating Photonic SNC SNC0-shelf-id SNC0-[0..992]-[1..1024]
AID
Terminating SNC AID SNC-shelf-id SNC-[0..992]-[1025..2048]
Terminating Photonic SNC SNC0-shelf-id SNC0-[0..992]-[1025..2048]
AID
All originating and SNC-shelf-ALL SNC-[0..992]-ALL
terminating SNCs on shelf
All originating and SNC0-shelf-ALL SNC0-[0..992]-ALL
terminating Photonic SNCs
on shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbrfilter string Specifies SNC retrieval Specifies if the SNC
( min len=4 max len=70 ) filter values. with the specific circuit
ID is to be retrieved, if
only originating SNCs
are to be retrieved, or
if only terminating
SNCs are to retrieved.
Values: <Circuit ID
string>, ORIG, TERM
Syntax Definition
Parameter Attributes Description Notes
aid M aid
absol-route-diversity O Specify if Absolute
Route Diversity (ARD)
is enabled.
assoc-sncg O Specifies Associated Format: SNCG0 AID
SNCG aid or NONE-<shelf>.This
parameter is only
applicable to photonics
backoff-period O Back-off period for The back-off period
retrying SNC setup (in doubles for each
seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
bit-rate O Define the bit rate of
flex.
ccmode O Specify the capacity In case MCCTTP
change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
cktid O Circuit identifier tagged
against cross-
connections created
for this SNC.
corouted-snc O Specifies the Co- Format: NONE-<shelf>
Routed SNC if which OR CRSNC-<shelf>-
this SNC is a member. <id>. Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
cost-crit-admin-weight O The cost criteria This parameter is only
setting for admin applicable to OTN.
weight.
cost-crit-delay O The cost criteria This parameter is only
setting for delay of the applicable to OTN.
home path.
cost-criteria O The cost criteria Supported for OTN
applicable for this only.
connection. This is
applicable for the
originating end SNC
only.
datapath-fault-action O Indicates whether an This parameter is
ALARM will be raised aplicable to L0
or MR will be done on Photonics only. Default
SNC Datapath is ALARM
Fault.Default is
ALARM
datapath-fault-alm-time O Specifies in minutes A value of 0 specifies
how long to wait before that the alarm is never
raising the SNC to be raised.
datapath fault alarm. Otherwise, a value of 5
to 30 minutes can be
specified. This
parameter is only
applicable to
photonics.
dtl-excl O Specifies whether to For SONET/SDH and
exclusively use the photonics, YES
DTL set specified by indicates the DTL list
DTLSN. specified in the
DTLSET shall
exclusively be used
and NO indicates the
DTL list specified in
the DTLSET shall
preferably be used.
For OTN, the values
DISABLE, WORKING,
WORKINGPROTECT
and PREFERRED are
used.
dtl-set-name O DTL set to be used for Format: DTLSET AID
this SNC. or NONE-<shelf>.
dtl-uuid O A string of 32 Each UUID is
Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
end-pt-size O End-point size type for This parameter is not
the SNC. applicable to
photonics.
frequency O Specifies the explicit This parameter is only
centre frequency to applicable to
use for the service. Photonics.
The value 0 (default)
means the system will
select the frequency.
All SNCs in an SNCG
must all be explicit or
all must be implicit.
generic-end-point O Specifies whether This parameter is only
Generic End Point applicable to OTN.
(GEP) method is
allowed.
grouped O Specifies, Is SNC part This parameter is only
of SNCG. It is an applicable to
optional attribute and Photonics.
Default value would be
NO. value =YES/NO
home-dtl-act O Indicates if the home
DTL is currently active.
home-dtl-avail O Indicates if the home
DTL is currently
available.
home-path-preempt O Specifies the Home This parameter is only
Path Preempt applicable to OTN.
capability definition.
incarnation O Indicates the SNC When the SNC re-
Incarnation Number. routes, its incarnation
number will change.
label M Label of this object.
local-end-point M Local end-point of this Values: CTP AID, VCP
SNC. AID, VEP AID, ADJ
AID, OCH AID,
OSRPLAG AID, or
SONET Payload AID.
max-adm-weight O SONET/SDH and
Photonics: Maximum
admin weight allowed
for this connection.
OTN:Maximum admin
weight allowed for the
home path.
max-delay O Maximum delay This parameter is only
allowed for the home applicable to OTN.
path (in
microseconds).
max-freq O R Constrain the This parameter is only
frequency allocated applicable to
upper bound (in THz) Photonics.
mesh-rest O Indicates if mesh- Always OFF for P-
restoration is enabled SNC.
for this SNC.
min-freq O R Constrain the This parameter is only
frequency allocated applicable to
lower bound (in THz) Photonics.
mode O Specifies the SNC This parameter is only
mode applicable to OTN.
mrccmode O Specify the mesh In case MCCTTP
restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
name O Name of this SNC. Supported for OTN
only. Default: SNC AID
nv-dtl-set-name O Non-viable DTL set to Format: NVDTLSET
be used for this SNC. AID or NONE-<shelf>.
This parameter is only
applicable to
photonics.
origin-drop-side-prot- O Specifies drop side For photonics, only
state protection state for the UNPROTECTED is
SNC on the originating applicable.
node.
origin-net-side-prot- O Specifies network side For photonics, only
state protection state for the UNPROTECTED is
SNC on the originating applicable.
node.
peer-origin O The peer originating Only applicable to
node name specifies SNCPs. Maximum of
the node name from 20 characters for
which the peer SNC photonics.
originates.
peer-snc O Identifies the peered Having a peer
SNC on this local node indicates that this SNC
or on the node is part of an SNCP.
specified in parameter Format: SNC AID for
PEERORIGIN. 6500, SNC name for
CD/54xx.
primary-ovpn-ids O L The primary optical Supports up to 4 ID's
virtual private network in an ampersand
ID list delimited quoted
string. This parameter
is only applicable to
OTN.
priority M Priority level of this
SNC connection.
prot-cost-crit-adm- O The protect cost This parameter is only
weight criteria admin weight applicable to OTN.
setting.
prot-cost-crit-delay O The protect cost This parameter is only
criteria delay setting. applicable to OTN.
prot-diversity-type O This indicates the This parameter is only
required deversity applicable to OTN.
type.
prot-max-adm-weight O Maximum admin This parameter is only
weight allowed for the applicable to OTN.
protect path.
prot-max-delay O Maximum delay This parameter is only
allowed for the protect applicable to OTN.
path.
prot-type M The protection type OTN and photonics
parameter indicates only supports
the service class of UNPROTECTED_HIG
protection for the SNC. H and
UNPROTECTED_LO
W. SONET/SDH only
supports,
APS_VLSR_PROTEC
TED,
APS_VLSR_UNPROT
ECTED,
UNPROTECTED, and
UNPROTECTED_PR
OTECT.
regroom O Indicates if re-groom
operation can be
performed on this
SNC.
release-on-client-fail O Specifies the Release This parameter is only
on Client Failure applicable to OTN.
capability
release-on-client-fail- O Specifies the Release This parameter is only
holdoff on Client Failure hold applicable to OTN.
off
release-on-client-fail- O Specifies the Release This parameter is only
holdon on Client Failure hold applicable to OTN.
on in seconds
remote-ctp-path-term O Determines whether Valid for OTN only.
remote CTP is path
terminating or not
remote-end-point M Remote end-point of Values: OSRPLAG
this SNC. AID, VCP AID,
OTUTTP AID,
ODUTTP AID, ETTP
AID, STTP AID, FTTP
AID, VEP AID, ADJ
AID, OCH AID,
SONET Payload AID,
or the appropriate end-
point AID for a non-
6500 product
(CD/54xx).
remote-end-point-type O Indicates the type of This parameter is not
end-point specified in supported by
RMTEP. photonics.
remote-interop O The required
interoperation
equipment type of the
remote node. This
parameter is only
applicable to OTN.
remote-node M Specifies the name of Maximum of 20
the remote end node characters for
on which the SNC photonics.
terminates.
remote-path-protection O Indicates what path This parameter is not
protection is enabled applicable to
on the terminating drop photonics.
side of this SNC.
remote-time-slot O Timeslot to use when Specifies a list or
creating the remote range of timeslots.
end-point. Values for each
timeslot are from 1-32
for OTN and 1-192 for
SONET/SDH.
Example formats:
1&4&6 OR 1&&5. This
parameter is not
applicable to
photonics.
remote-ttp-mux O Describes the Valid for OTN only.
multiplex structure and
payload type for the far
end TTP in
accordance with ITU-T
G.709
resizable O Indicates if the
ODUFlex connection
has the capability to be
resized.
retain-home-path- O Specifies if the Retain Retain Home Path
capability Home Path capability provides the
is available. functionality of
retaining to the home
path and also updating
the current path to the
home path if needed.
This parameter is only
applicable to OTN.
revert-time O Amount of time for a Not applicable when
connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
revert-timer O Specifies whether the SNC_TIMEOFDAY is
connection is to revert only applicable to
to the original route OTN.
after a delay
(SNC_DELAY), the
connection is not to
revert to the original
route
(SNC_NO_REVERT),
or if the connection is
to revert at a certain
time(SNC_TIMEOFDA
Y).
rev-fail-count O Specifies the number This parameter is only
of windows during applicable to OTN.
which Time of Day
Reversion has failed.
rvrt-state O Specifies the reversion This parameter is only
state of the connection applicable to OTN.
secondary-ovpn-ids O The secondary optical Supports up to 4 ID's
virtual private network in an ampersand
ID list delimited quoted
string. NONE indicates
secondary OVPNID's
are not used. This
parameter is only
applicable to OTN.
snc-ep-state M SNC-specific state
information for the
end-point.
snc-integrity-check O Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
snc-line-type O Identifiers if this SNC
is the working or
protecting leg of an
SNCP.
snic-valid-path-detected O Specifies if a valid path This parameter is only
signal was detected for applicable to OTN.
this SNC.
takeover O Indicates the current This parameter is
cross-connection applicable to
takeover specification SONET/SDH and
value for this SNC. photonics.This
parameter is not
applicable to OTN.
tcm O Override the system TCM value of 0
default SNC TCM. disables TCM. This
parameter is only
applicable to OTN.
termin-drop-side-prot- O Specifies drop side For photonics, only
state protection state for the UNPROTECTED is
SNC on the applicable.
terminating node.
termin-net-side-prot- O Specifies network side For photonics, only
state protection state for the UNPROTECTED is
SNC on the applicable.
terminating node.
tod-revert-holdback- O Specifies if time of day Default value is YES.
enabled reversion holdback is This parameter is only
enabled. applicable to OTN.
tod-revert-holdback- O Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-period O Specifies the time This parameter is only
range (in minutes) applicable to OTN.
when it's acceptable to
do the TODR (home
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-prof-list O L List of time of day Grouping (&) is
reversion profiles that supported. This
are associated with parameter specifies a
this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
tod-revert-time O Specifies the time of Format is HH:MM, i.e.
day when to do 02:05, or 22:59.
reversion to the home Default value is 02:00.
path (home path must This parameter is only
be available). applicable to OTN.
tolerance O Define the tolerance in It is used for
ppm of oduflex before ODUFLEX
an LOF is declared.
trib-port O Tributary port for This parameter is only
creating line side CTPs applicable to OTN.
type M Type of this SNC,
dynamic or permanent.
wvl-grid O A hexadecimal number Each bit set within the
representing the vector number indicates
of wavelengths that which wavelength is
can be used by this currently configured.
SNC. Default WVLGRID is
all bits set. This
parameter is only
applicable to
photonics.
pst M Primary state of the
SNC.
sst O L Secondary state of the
SNC. This parameter
is only applicable to
photonics.
Output Parameter Description
Parameter Value Description Notes
aid ident aid
absol-route-diversity ON, OFF Specify if Absolute
Route Diversity (ARD)
is enabled.
assoc-sncg Originating SNCG0- SNCG0- Specifies Associated Format: SNCG0 AID
Photonic shelf-id [0..992]- SNCG aid or NONE-<shelf>.This
SNCG AID [1..1024] parameter is only
No non- NONE- NONE- applicable to photonics
sncg aid shelf [0..992]
backoff-period INT Back-off period for The back-off period
(1-30) retrying SNC setup (in doubles for each
seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
bit-rate string Define the bit rate of
( min len=0 max len=19 ) flex.
ccmode DTLMODE, MODE1, MODE2, Specify the capacity In case MCCTTP
MODE3 change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
cktid string Circuit identifier tagged
( min len=29 max len=70 ) against cross-
connections created
for this SNC.
corouted-snc Co-Routed CRSNC- CRSNC- Specifies the Co- Format: NONE-<shelf>
SNC AID shelf-id [0..992]- Routed SNC if which OR CRSNC-<shelf>-
[1..96] this SNC is a member. <id>. Default value is
No Co- NONE- NONE- NONE-<shelf>. This
Routed shelf [0..992] parameter is only
SNC applicable to OTN.
cost-crit-admin-weight MANDATORY
BESTEFFORT
DISABLE
cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
cost-criteria DELAY
ADMINWEIGHT
datapath-fault-action MR, ALARM Indicates whether an This parameter is
ALARM will be raised aplicable to L0
or MR will be done on Photonics only. Default
SNC Datapath is ALARM
Fault.Default is
ALARM
datapath-fault-alm-time INT Specifies in minutes A value of 0 specifies
(0-30) how long to wait before that the alarm is never
raising the SNC to be raised.
datapath fault alarm. Otherwise, a value of 5
to 30 minutes can be
specified. This
parameter is only
applicable to
photonics.
dtl-excl NO
YES
DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used for Format: DTLSET AID
AID shelf-id [0..992]- this SNC. or NONE-<shelf>.
[1..1024]
Photonic DTLSET0- DTLSET0-
DTL set shelf-id [0..992]-
AID [1..1024]
No DTL NONE- NONE-
set shelf [0..992]
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
end-pt-size STS1
STS3C
STS12C
STS24C
STS48C
STS192C
ODU0
ODU1
ODU2
ODU2E
ODU3
ODU4
ODUFLEX
frequency DECIMAL Specifies the explicit This parameter is only
(0.000000, 186.325000- centre frequency to applicable to
190.975000, 191.325000- use for the service. Photonics.
196.125000) The value 0 (default)
means the system will
select the frequency.
All SNCs in an SNCG
must all be explicit or
all must be implicit.
generic-end-point YES
NO
grouped YES
NO
home-dtl-act YES
NO
home-dtl-avail YES
NO
home-path-preempt DISABLED
RESERVED
incarnation INT Indicates the SNC When the SNC re-
Incarnation Number. routes, its incarnation
number will change.
label string Label of this object.
( min len=0 max len=64 )
local-end-point string Local end-point of this Values: CTP AID, VCP
SNC. AID, VEP AID, ADJ
AID, OCH AID,
OSRPLAG AID, or
SONET Payload AID.
max-adm-weight INT SONET/SDH and
(0-1310700) Photonics: Maximum
admin weight allowed
for this connection.
OTN:Maximum admin
weight allowed for the
home path.
max-delay INT Maximum delay This parameter is only
(0-4000000) allowed for the home applicable to OTN.
path (in
microseconds).
max-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) upper bound (in THz) Photonics.
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNC.
for this SNC.
min-freq DECIMAL Constrain the This parameter is only
(186.325000-190.975000, frequency allocated applicable to
191.325000-196.125000) lower bound (in THz) Photonics.
mode OTN, PKTRSRVD, PKTNORSRVD Specifies the SNC This parameter is only
mode applicable to OTN.
mrccmode DTLMODE, MODE1, MODE2, Specify the mesh In case MCCTTP
MODE3 restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
name string Name of this SNC. Supported for OTN
( min len=0 max len=40 ) only. Default: SNC AID
nv-dtl-set-name No non- NONE- NONE- Non-viable DTL set to Format: NVDTLSET
viable DTL shelf [0..992] be used for this SNC. AID or NONE-<shelf>.
set This parameter is only
applicable to
photonics.
origin-drop-side-prot- HIGH_ORDER, UNPROTECTED Specifies drop side For photonics, only
state protection state for the UNPROTECTED is
SNC on the originating applicable.
node.
origin-net-side-prot- HIGH_ORDER, UNPROTECTED Specifies network side For photonics, only
state protection state for the UNPROTECTED is
SNC on the originating applicable.
node.
peer-origin string The peer originating Only applicable to
( min len=1 max len=40 ) node name specifies SNCPs. Maximum of
the node name from 20 characters for
which the peer SNC photonics.
originates.
peer-snc string Identifies the peered Having a peer
SNC on this local node indicates that this SNC
or on the node is part of an SNCP.
specified in parameter Format: SNC AID for
PEERORIGIN. 6500, SNC name for
CD/54xx.
primary-ovpn-ids string The primary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. This parameter
is only applicable to
OTN.
priority LOW
HIGH
prot-cost-crit-adm- MANDATORY
weight BESTEFFORT
DISABLE
prot-cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
prot-diversity-type LINK LINK diversity type is
required.
PBID PBID diversity type is
required.
NODE NODE diversity type is
required.
prot-max-adm-weight INT Maximum admin This parameter is only
(0-1310700) weight allowed for the applicable to OTN.
protect path.
prot-max-delay INT Maximum delay This parameter is only
(0-4000000) allowed for the protect applicable to OTN.
path.
prot-type APS_VLSR_PROTECTED
APS_VLSR_UNPROTECTED
UNPROTECTED
UNPROTECTED_HIGH
UNPROTECTED_LOW
UNPROTECTED_PROTECT
regroom ON, OFF Indicates if re-groom
operation can be
performed on this
SNC.
release-on-client-fail DISABLED, PORT, PAYLOAD Specifies the Release This parameter is only
on Client Failure applicable to OTN.
capability
release-on-client-fail- IMMEDIATE, ALARM Specifies the Release This parameter is only
holdoff on Client Failure hold applicable to OTN.
off
release-on-client-fail- INT Specifies the Release This parameter is only
holdon (5) on Client Failure hold applicable to OTN.
on in seconds
remote-ctp-path-term YES
NO
remote-end-point string Remote end-point of Values: OSRPLAG
this SNC. AID, VCP AID,
OTUTTP AID,
ODUTTP AID, ETTP
AID, STTP AID, FTTP
AID, VEP AID, ADJ
AID, OCH AID,
SONET Payload AID,
or the appropriate end-
point AID for a non-
6500 product
(CD/54xx).
remote-end-point-type CTP
VCP
VEP
GEP
OSRPLAG
remote-interop OTHER Interop with equipment
other than 2G5 MOTR
2G5MOTR Interop with equipment
2G5 MOTR
remote-node string Specifies the name of Maximum of 20
( min len=1 max len=40 ) the remote end node characters for
on which the SNC photonics.
terminates.
remote-path-protection NONE
HIGH_ORDER
LOW_ORDER
remote-time-slot string Timeslot to use when Specifies a list or
( min len=1 max len=192 ) creating the remote range of timeslots.
end-point. Values for each
timeslot are from 1-32
for OTN and 1-192 for
SONET/SDH.
Example formats:
1&4&6 OR 1&&5. This
parameter is not
applicable to
photonics.
remote-ttp-mux ODTU01_PT20
ODTU12_PT20
ODTU12_PT21
ODTU13_PT21
ODTU23_PT20
ODTU23_PT21
ODTU34_PT21
ODTU24_PT21
ODTU14_PT21
ODTUK_TS
OTUK
NONE
resizable YES
NO
retain-home-path- YES
capability NO
revert-time INT Amount of time for a Not applicable when
(300-86400) connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
revert-timer SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
rev-fail-count INT Specifies the number This parameter is only
of windows during applicable to OTN.
which Time of Day
Reversion has failed.
rvrt-state NA
IDLE
PENDING_TODR
PENDING_NA
PENDING_HB
PENDING_SD
PENDING_OTHER
secondary-ovpn-ids string The secondary optical Supports up to 4 ID's
( min len=1 max len=15 ) virtual private network in an ampersand
ID list delimited quoted
string. NONE indicates
secondary OVPNID's
are not used. This
parameter is only
applicable to OTN.
snc-ep-state ORIG_DOWN, ORIG_CREATING, SNC-specific state
ORIG_STARTING, information for the
ORIG_PROTECTING, end-point.
ORIG_WORKING,
ORIG_RECOVERING,
ORIG_MBB_ACTIVE,
ORIG_MBB_SWITCH,
ORIG_PENDING,
ORIG_LOCK_PENDING,
ORIG_EDITING, TERM_DOWN,
TERM_WAITING,
TERM_WORKING_CONNECTED,
DEGRADED
snc-integrity-check ON, OFF Specifies if the SNC This parameter is only
Integrity Check applicable to OTN.
capability is enabled or
disabled.
snc-line-type WORKING, PROTECT Identifiers if this SNC
is the working or
protecting leg of an
SNCP.
snic-valid-path-detected YES, NO Specifies if a valid path This parameter is only
signal was detected for applicable to OTN.
this SNC.
takeover YES, NO Indicates the current This parameter is
cross-connection applicable to
takeover specification SONET/SDH and
value for this SNC. photonics.This
parameter is not
applicable to OTN.
tcm INT Override the system TCM value of 0
(0-6) default SNC TCM. disables TCM. This
parameter is only
applicable to OTN.
termin-drop-side-prot- HIGH_ORDER, UNPROTECTED Specifies drop side For photonics, only
state protection state for the UNPROTECTED is
SNC on the applicable.
terminating node.
termin-net-side-prot- HIGH_ORDER, UNPROTECTED Specifies network side For photonics, only
state protection state for the UNPROTECTED is
SNC on the applicable.
terminating node.
tod-revert-holdback- YES, NO Specifies if time of day Default value is YES.
enabled reversion holdback is This parameter is only
enabled. applicable to OTN.
tod-revert-holdback- time Specifies the time of Format is HH-MM, i.e.
period day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-period INT Specifies the time This parameter is only
(5-300) range (in minutes) applicable to OTN.
when it's acceptable to
do the TODR (home
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-prof-list Time of TODRPROF TODRPRO List of time of day Grouping (&) is
Day -shelf- F-[0..992]- reversion profiles that supported. This
Reversion id [1..100] are associated with parameter specifies a
Profile AID this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>. This
parameter is only
applicable to OTN.
tod-revert-time time Specifies the time of Format is HH:MM, i.e.
day when to do 02:05, or 22:59.
reversion to the home Default value is 02:00.
path (home path must This parameter is only
be available). applicable to OTN.
tolerance string Define the tolerance in It is used for
( min len=0 max len=19 ) ppm of oduflex before ODUFLEX
an LOF is declared.
trib-port INT Tributary port for This parameter is only
(0-32 Default=0) creating line side CTPs applicable to OTN.
type DYNAMIC
PERM
wvl-grid string A hexadecimal number Each bit set within the
( min len=0 max len=96 ) representing the vector number indicates
of wavelengths that which wavelength is
can be used by this currently configured.
SNC. Default WVLGRID is
all bits set. This
parameter is only
applicable to
photonics.
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
OOS-AU Out-of-service
autonomous from a
failure detected point
of view. It is not out of
service from a state
point of view. Alarm is
raised if the entity is
not able to perform its
provisioned functions
OOS-AUMA Out-of-service
autonomous
management - the
entity is not able to
perform its provisioned
functions and is
purposefully removed
from service
sst SGEO Supporting Group
Entity Outage: The
SNC is not fully
operational because
one or more
supporting entities
(e.g. DOC channel) is
not operational.
FLT Fault: The SNC is
faulted and an alarm
has been raised.
AID Descriptions
AID Type Format Values
Originating SNC AID SNC-shelf-id SNC-[0..992]-[1..1024]
Originating Photonic SNC SNC0-shelf-id SNC0-[0..992]-[1..1024]
AID
All originating SNCs on SNC-shelf-ALL SNC-[0..992]-ALL
shelf
All originating Photonic SNC0-shelf-ALL SNC0-[0..992]-ALL
SNCs on shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
member-filter WORKING, PROTECTION, HOME Specifies the type of
route to be retrieved.
Syntax Definition
Parameter Attributes Description Notes
aid M aid
adv-wl O A hexadecimal number Each bit set within the
which represents the number indicates
current wavelength which wavelength is
availability. currently available.
This parameter is only
applicable to
photonics.
assoc-fail-hop O The associated hop This parameter is not
whose failure should applicable to
trigger the use of the SONET/SDH. Format
DTLDATA. is a quoted string with
the following format:
"nodeName,linkId",
where nodeName is
the OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), or spaces
are in the name, e.g.
\"My Node\").
nodeName can be 1 to
40 characters for OTN
and 1 to 20 characters
for photonics. linkId is
a value 1 to 2048 for
OTN and 1 to 25438
for photonics.
dtl M Indicates the entire Format is a quoted
DTL route for the string containing a list
specified SNC of up to 40 hops with
excluding the the following format: "
terminating node. <hop1>[&<hop2>][&
<hop3>]..[&<hop40>]".
Each hop has a format
of: nodeName,linkId.
nodeName is the
OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), spaces,
colons(:), or
ampersands (&) are in
the name, e.g. \"My
Node\"). nodeName
can be 1 to 40
characters for
SONET/SDH and
OTN, and 1 to 20
characters for
photonics. linkId is a
value 1 to 2048 for
SONET/SDH and
OTN, and 1 to 25438
for photonics.
dtl-cost O Indicates the DTL cost. This parameter is not
applicable to
SONET/SDH.
dtl-name O The DTL AID This parameter is not
associated with this applicable to
protection path SONET/SDH.
route-type M Specifies the type of
route.
term-node-name O The OSRP node name This parameter is not
of where the SNC applicable for OTN
terminates. protection routes.
Maximum of 20
characters for
photonics.
AID Descriptions
AID Type Format Values
Originating Photonic SNCG SNCG0-shelf-id SNCG0-[0..992]-[1..1024]
AID
Input Parameter Description
Parameter Value Description Notes
absol-route-diversity ON, OFF Indicates if Absolute It can only be set to
Route Diversity (ARD) ON for MR-SNCGs.
is enabled, Can only
be set to ON for MR-
SNCGs.
bckop INT Back-off period for Default is 2 seconds
(1-30) retrying SNCG setup for photonics, and 1
(in seconds). second for
SONET/SDH . The
back-off period
doubles for each
subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
ccmode DTLMODE, MODE1, MODE2, Specify the capacity In case MCCTTP
MODE3 change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
contiguous YES, NO Single Contiguous MC Single Contiguous MC.
Use, For Photonics For Photonics values
values are YES | NO, are YES | NO, Default
Default = YES. = YES.
dtl-excl NO
YES
DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used by Format: DTLSET AID
AID shelf-id [0..992]- all member SNCs.. or NONE-<shelf>.
[1..1024] Default: NONE-
Photonic DTLSET0- DTLSET0- <shelf>.
DTL set shelf-id [0..992]-
AID [1..1024]
No DTL NONE- NONE-
set shelf [0..992]
dtl-uuid string A string of 32 Each UUID is
( min len=36 max len=36 ) Hexadecimal Digits in represented by 32
five groups seperated hexadecimal digits
by hypens in the form displayed in five
xxxxxxxx-xxxx-Mxxx- groups separated by
Nxxx-xxxxxxxxxxxx for hyphens in the form
a total of 36 xxxxxxxx-xxxx-Mxxx-
charatcters, Nxxx-xxxxxxxxxxxx for
representing the a total of 36
Universally Unique characters.
Identifier of the object.
label string Label of this object. Default: Empty string (
( min len=0 max len=64 ) min len=0 max len=64
). This is the label of
the SNCG object. It is
not applied to the SNC
members.
max-adm-weight INT SONET/SDH and default value is 0.
(0-1310700 Default=0) Photonics: Maximum
admin weight allowed
for this connection,
default value is 0.
max-freq DECIMAL Constrain the Upper frequency limit
(186.325000-190.975000, frequency allocated - for Media channel in
191.325000-196.125000) upper bound (in THz). THz.
max-freq-db DECIMAL Media Channel Upper Media Channel Upper
(0-4800.000) Dead Band, in GHz. Dead Band in GHz.
max-snc-spacing DECIMAL Maximum allowed Maximum allowed
(0-4800.000 Default=4800) spectral Spacing within spectral Spacing.
media channel, in
GHz. default value
:4800GHz
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNCG.
for this SNCG, Always
OFF for P-SNCG.
min-freq DECIMAL Constrain the Lower frequency limit
(186.325000-190.975000, frequency allocated - for Media channel in
191.325000-196.125000) lower bound (in THz). THz.
min-freq-db DECIMAL Media Channel Lower Media Channel Lower
(0-4800.000) Dead Band, in GHz. Dead Band in GHz.
default value :SYS
DBDFLT value
mrccmode DTLMODE, MODE1, MODE2, Specify the mesh In case MCCTTP
MODE3 restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
nv-dtl-set-name No non- NONE- NONE- Non-viable DTL set to Format: NVDTLSET
viable DTL shelf [0..992] be used for this SNCG. AID or NONE-<shelf>.
set Default: NONE-
<shelf>. This
parameter is only
applicable to
photonics.
peer-origin string The peer originating Only applicable to
( min len=1 max len=40 ) node name specifies SNCGPs. Default:
the node name from Local node for
which the peer SNCG SNCGPs, empty string
originates. otherwise. Maximum
of 20 characters for
photonics.
peer-sncg string AID of the paired Having a peer
SNCG on this local indicates that this
node. SNCG is part of an
SNCGP. Format:
SNCG AID for 6500,
Default: Undefined
value.
prot-type UNPROTECTED_HIGH
UNPROTECTED_LOW
remote-node string Specifies the name of Maximum of 20
( min len=1 max len=40 ) the remote end node characters for
on which all SNC photonics.
member connections
terminate..
rvrt-time SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
sncglinetype WORKING, PROTECT Identifiers if this SNCG Mandatory for
is the working or SNCGPs. Default:
protecting leg of an Undefined value.
SNCGP.
snc-list Unordered list of User will provide SNC
Originating SNC0- SNC0-
Photonic shelf-id [0..992]- member SNCs. MAX aids. Format: SNC0-
SNC AID [1..1024] SNCs we can have 16 <shelf>-<id>&SNC0-
<shelf>-<id>&SNC0-
<shelf>-<id>&..
time-to-revert INT Amount of time for a Not applicable when
(300-86400 Default=300) connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
type DYNAMIC
PERM
validate YES
NO
pst IS In Service
OOS-MA Out-of-service
maintenance for
provisioning memory
administration
AID Descriptions
AID Type Format Values
Originating Photonic SNCG SNCG0-shelf-id SNCG0-[0..992]-[1..1024]
AID
Input Parameter Description
Parameter Value Description Notes
absol-route-diversity ON, OFF Indicates if Absolute It can only be set to
Route Diversity (ARD) ON for MR-SNCGPs.
is enabled, Can only
be set to ON for MR-
SNCGPs.
bckop INT Back-off period for The back-off period
(1-30) retrying SNCG setup doubles for each
(in seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, ...
ccmode DTLMODE, MODE1, MODE2, Specify the capacity In case MCCTTP
MODE3 change creation/deletion is
mode(CCMODE) triggered through
manual operations
such as
ENT/RMV/RST
SNC/SNCG, MSP,
revert etc
contiguous YES, NO Single Contiguous MC Single Contiguous MC.
Use, For Photonics For Photonics values
values are YES | NO, are YES | NO, Default
Default = YES. = YES.
dtl-excl NO
YES
DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used by Format: DTLSET AID
AID shelf-id [0..992]- all member SNCs.. or NONE-<shelf>.
[1..1024] Default: NONE-
Photonic DTLSET0- DTLSET0- <shelf>.
DTL set shelf-id [0..992]-
AID [1..1024]
No DTL NONE- NONE-
set shelf [0..992]
label string Label of this object. Default: Empty string.
( min len=0 max len=64 ) This is the label of the
SNCG object. It is not
applied to the SNC
members.
max-adm-weight INT SONET/SDH and default value is 0.
(0-1310700 Default=0) Photonics: Maximum
admin weight allowed
for this connection,
default value is 0.
max-freq DECIMAL Constrain the Upper frequency limit
(186.325000-190.975000, frequency allocated for Media channel in
191.325000-196.125000) upper bound (in THz). THz.
max-freq-db DECIMAL Media Channel Upper Media Channel Upper
(0-4800.000) Dead Band, in GHz. Dead Band in GHz.
max-snc-spacing DECIMAL Maximum allowed Maximum allowed
(0-4800.000 Default=4800) spectral Spacing within spectral Spacing.
media channel, in
GHz. default value
:4800GHz
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNCG.
for this SNCG, Always
OFF for P-SNCG.
min-freq DECIMAL Constrain the Lower frequency limit
(186.325000-190.975000, frequency allocated for Media channel in
191.325000-196.125000) lower bound (in THz). THz.
min-freq-db DECIMAL Media Channel Lower Media Channel Lower
(0-4800.000) Dead Band, in GHz. Dead Band in GHz.
mrccmode DTLMODE, MODE1, MODE2, Specify the mesh In case MCCTTP
MODE3 restorations capacity creation /deletion is
change triggered through
mode(MRCCMODE) mesh restorations
nv-dtl-set-name No non- NONE- NONE- Non-viable DTL set to Format: NVDTLSET
viable DTL shelf [0..992] be used for this SNCG. AID or NONE-<shelf>.
set Default: NONE-
<shelf>. This
parameter is only
applicable to
photonics.
peer-origin string The peer originating Only applicable to
( min len=1 max len=40 ) node name specifies SNCGPs. Default:
the node name from Local node for
which the peer SNCG SNCGPs, empty string
originates. otherwise. Maximum
of 20 characters for
photonics.
peer-sncg string AID of the paired Having a peer
SNCG on this local indicates that this
node. SNCG is part of an
SNCGP. Format:
SNCG AID for 6500,
Default: Undefined
value.
prot-type UNPROTECTED_HIGH
UNPROTECTED_LOW
remote-node string Specifies the name of Maximum of 20
( min len=1 max len=40 ) the remote end node characters for
on which all SNC photonics. This
member connections attribute is editable
terminate. only when SNCG is in
OOS-MA state.
route-operation MANSWITCH
REGROOM
RESIZE
REVERT
rvrt-time SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
sncglinetype WORKING, PROTECT Identifiers if this SNCG Mandatory for
is the working or SNCGPs. Default:
protecting leg of an Undefined value.
SNCGP.
snc-list Originating SNC0- SNC0- Unordered list of User will provide SNC
Photonic shelf-id [0..992]- member SNCs. MAX aids. Format: SNC0-
SNC AID [1..1024] SNCs we can have 16 <shelf>-<id>&SNC0-
<shelf>-<id>&SNC0-
<shelf>-<id>&..
time-to-revert INT Amount of time for a Not applicable when
(300-86400 Default=300) connection to be MESHRST is set to
reverted to the original OFF.
route (sec).
type DYNAMIC
PERM
validate YES
NO
Top of OSRP Section
osrp snc-group disable
Description: Place a Subnetwork Connection Group into an out-of-service maintenance state
CLI command: osrp snc-group disable
Security Level: 3
Input syntax osrp snc-group disable <aid>
AID Descriptions
AID Type Format Values
Originating Photonic SNCG SNCG0-shelf-id SNCG0-[0..992]-[1..1024]
AID
AID Descriptions
AID Type Format Values
Co-Routed SNC AID CRSNC-shelf-id CRSNC-[0..992]-[1..96]
Input Parameter Description
Parameter Value Description Notes
label string Label of this object. Default: Empty string.
( min len=0 max len=64 ) This is the label of the
CRSNC group object.
It is not applied to the
SNC members.
snc Originating SNC- SNC- Seed SNC for this Format is SNC AID. All
SNC AID shelf-id [0..992]- CRSNC group. SNC related parms on
[1..1024] the group are initially
inherited from the
seed.
AID Descriptions
AID Type Format Values
Co-Routed SNC AID CRSNC-shelf-id CRSNC-[0..992]-[1..96]
Input Parameter Description
Parameter Value Description Notes
backoff-period INT Back-off period for The back-off period
(1-30) retrying SNC setup (in doubles for each
seconds). subsequent retry up to
30 seconds, then
becomes 30 seconds
thereafter. For
example, if set to 2
seconds, then the
back-off period is (in
seconds) 2, 4, 8, 16,
30, 60, 90, etc. Value
is applied to all SNC
members of the group.
cost-crit-adm-weight MANDATORY
BESTEFFORT
DISABLE
cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
cost-criteria DELAY
ADMINWEIGHT
dtl-excl DISABLE
WORKING
WORKINGPROTECT
PREFERRED
dtl-set-name DTL set DTLSET- DTLSET- DTL set to be used by Format: DTLSET AID
AID shelf-id [0..992]- all member SNC or NONE-<shelf>.
[1..1024] connections. Value is applied to all
Photonic DTLSET0- DTLSET0- SNC members of the
DTL set shelf-id [0..992]- group.
AID [1..1024]
No DTL NONE- NONE-
set shelf [0..992]
home-path-preempt DISABLED
RESERVED
label string Label of this object.
( min len=0 max len=64 )
make-home-path YES
NO
max-adm-weight INT Maximum admin Value is applied to all
(0-1310700) weight allowed for the SNC members of the
home path. group.
max-delay INT Maximum delay Value is applied to all
(0-4000000) allowed for the home SNC members of the
path (in group.
microseconds).
mesh-rest ON, OFF Indicates if mesh- Always OFF for P-
restoration is enabled SNC. Value is applied
for all SNC member to all SNC members of
connections. the group.
num-members INT NUMMEMBERS can Value can be 1 to 10.
(1-10) only be specified as Editable only on a
part of Regroom to regroom operation.
indicate total number
of member SNC will be
requested for the
CRSNC. It is typically
used when additional
member SNCs need to
be added to the
CRSNC.
ovpn-id INT Optical Virtual Private Value is applied to all
(0-255) Network ID. SNC members of the
group.
prot-cost-crit-adm- MANDATORY
weight BESTEFFORT
DISABLE
prot-cost-crit-delay MANDATORY
BESTEFFORT
DISABLE
prot-max-adm-weight INT Maximum admin Value is applied to all
(0-1310700) weight allowed for the SNC members of the
protect path. group.
prot-max-delay INT Maximum delay Value is applied to all
(0-4000000) allowed for the protect SNC members of the
path. group.
prot-type UNPROTECTED_HIGH
UNPROTECTED_LOW
regroom ON, OFF Indicates if re-groom
operation can be
performed on the SNC
member connections.
Value is applied to all
SNC members of the
group.
remote-node string Specifies the name of Value is applied to all
( min len=1 max len=40 ) the remote end node SNC members of the
on which all SNC group.
member connections
terminate.
retain-home-path- YES
capability NO
revert-time INT Amount of time for Not applicable when
(300-86400) SNC member MESHRST is set to
connections to be OFF. Value is applied
reverted to the original to all SNC members of
route (sec). the group.
route-operation MANSWITCH
REGROOM
RESIZE
REVERT
timed-revert SNC_NO_REVERT
SNC_DELAY
SNC_TIMEOFDAY
tod-revert-holdback- time Specifies the time of Format is HH-MM, i.e.
delay day reversion holdback 02-05 or 22-59. Range
period. is 00-05 - 72-00.
Default is 24-00. This
parameter is only
applicable to OTN.
tod-revert-holdback- YES
enable NO
tod-revert-period INT Specifies the time Value is applied to all
(5-300) range (in minutes) SNC members of the
when it's acceptable to group.
do the TODR (home
route must be
available during this
window), otherwise
wait 24 hours to try
again.
tod-revert-profile-list Time of TODRPROF TODRPRO List of time of day Grouping (&) is
Day -shelf- F-[0..992]- reversion profiles that supported. This
Reversion id [1..100] are associated with parameter specifies a
Profile AID this SNC list of up to 7 TODR
Profiles in the following
format: NONE-<shelf>
OR TODRPROF-
<shelf>-
<id>&TODRPROF-
<shelf>-<id>&...
Default value is
NONE-<shelf>
tod-revert-time time Specifies the time of Format is HH-MM, i.e.
day when to do 02-05 or 22-59. Range
reversion to the home is 00-00 to 23-59.
path (home path must Value is applied to all
be available). SNC members of the
group.
type DYNAMIC
PERM
AID Descriptions
AID Type Format Values
Co-Routed SNC AID CRSNC-shelf-id CRSNC-[0..992]-[1..96]
Input Parameter Description
Parameter Value Description Notes
snc Originating SNC- SNC- AID of SNC being This paramater is
SNC AID shelf-id [0..992]- deleted from the mandatory.
[1..1024] CRSNC group.
AID Descriptions
AID Type Format Values
Co-Routed SNC AID CRSNC-shelf-id CRSNC-[0..992]-[1..96]
All Co-Routed SNCs on CRSNC-shelf-ALL CRSNC-[0..992]-ALL
shelf
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
mbr-filter WORKING, PROTECTION, HOME Specifies the type of
route to be retrieved.
Syntax Definition
Parameter Attributes Description Notes
aid M aid
as-fail-hop O The associated hop Format is a quoted
whose failure should string with the
trigger the use of the following format:
DTLDATA. "nodeName,linkId",
where nodeName is
the OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), or spaces
are in the name, e.g.
\"My Node\").
nodeName can be 1 to
40 characters. linkId is
a value 1 to 2048.
dtl M Indicates the entire Format is a quoted
DTL route for the string containing a list
specified CRSNC of up to 40 hops with
excluding the the following format: "
terminating node. <hop1>[&<hop2>][&
<hop3>]..[&<hop40>]".
Each hop has a format
of: nodeName,linkId.
nodeName is the
OSRP node name
(can optionally be
specified with \"
around the name if
commas(,), spaces,
colons(:), or
ampersands (&) are in
the name, e.g. \"My
Node\"). nodeName
can be 1 to 40
characters. linkId is a
value 1 to 2048.
dtl-cost O Indicates the DTL cost.
dtl-name O The DTL AID
associated with this
path.
route-type M Specifies the type of
route.
term-node-name O The OSRP node name This parameter is not
of where the CRSNC applicable for OTN
terminates. protection routes.
AID Descriptions
AID Type Format Values
Time of Day Reversion TODRPROF-shelf-id TODRPROF-[0..992]-[1..100]
Profile AID
Input Parameter Description
Parameter Value Description Notes
friday-enable YES Time of day reversion
profile is enabled on
Friday.
NO Time of day reversion
profile is disabled on
Friday.
friday-todr time Friday start time of day The format is "HH-
reversion. MM"
friday-todr-period INT Friday time of day
(5-300 Default=20) reversion period.
monday-enable YES Time of day reversion
profile is enabled on
Monday.
NO Time of day reversion
profile is disabled on
Monday.
monday-todr time Monday start time of The format is "HH-
day reversion. MM"
monday-todr-period INT Monday time of day
(5-300 Default=20) reversion period.
multi-day YES This is a multiday
profile.
NO This is a single day
profile.
name string A time of day reversion Nodal unique identifier
( min len=1 max len=64 ) profile name that is up to 64 characters
unique across the
OSRP network.
profen YES Time of day reversion
profile is enabled.
NO Time of day reversion
profile is disabled.
saturday-enable YES Time of day reversion
profile is enabled on
Saturday.
NO Time of day reversion
profile is disabled on
Saturday.
saturday-todr time Saturday start time of The format is "HH-
day reversion. MM"
saturday-todr-period INT Saturday time of day
(5-300 Default=20) reversion period.
sunday-enable YES Time of day reversion
profile is enabled on
Sunday.
NO Time of day reversion
profile is disabled on
Sunday.
sunday-todr time Sunday start time of The format is "HH-
day reversion. MM"
sunday-todr-period INT Sunday time of day
(5-300 Default=20) reversion period.
thursday-enable YES Time of day reversion
profile is enabled on
Thursday.
NO Time of day reversion
profile is disabled on
Thursday.
thursday-todr time Thursday start time of The format is "HH-
day reversion. MM"
thursday-todr-period INT Thursday time of day
(5-300 Default=20) reversion period.
tuesday-enable YES Time of day reversion
profile is enabled on
Tuesday.
NO Time of day reversion
profile is disabled on
Tuesday.
tuesday-todr time Tueday start time of The format is "HH-
day reversion. MM"
tuesday-todr-period INT Tuesday time of day
(5-300 Default=20) reversion period.
wednesday-enable YES Time of day reversion
profile is enabled on
Wednesday.
NO Time of day reversion
profile is disabled on
Wednesday.
wednesday-todr time Wednesday start time The format is "HH-
of day reversion. MM"
wednesday-todr-period INT Wednesday time of
(5-300 Default=20) day reversion period.
AID Descriptions
AID Type Format Values
Time of Day Reversion TODRPROF-shelf-id TODRPROF-[0..992]-[1..100]
Profile AID
Input Parameter Description
Parameter Value Description Notes
friday-enable YES Time of day reversion
profile is enabled on
Friday.
NO Time of day reversion
profile is disabled on
Friday.
friday-todr time Friday start time of day The format is "HH-
reversion. MM"
friday-todr-period INT Friday time of day
(5-300 Default=20) reversion period.
monday-enable YES Time of day reversion
profile is enabled on
Monday.
NO Time of day reversion
profile is disabled on
Monday.
monday-todr time Monday start time of The format is "HH-
day reversion. MM"
monday-todr-period INT Monday time of day
(5-300 Default=20) reversion period.
name string A TODR profile name Nodal unique identifier
( min len=1 max len=64 ) that is unique across up to 64 characters
the OSRP network.
profen YES Time of day reversion
profile is enabled.
NO Time of day reversion
profile is disabled.
saturday-enable YES Time of day reversion
profile is enabled on
Saturday.
NO Time of day reversion
profile is disabled on
Saturday.
saturday-todr time Saturday start time of The format is "HH-
day reversion. MM"
saturday-todr-period INT Saturday time of day
(5-300 Default=20) reversion period.
sunday-enable YES Time of day reversion
profile is enabled on
Sunday.
NO Time of day reversion
profile is disabled on
Sunday.
sunday-todr time Sunday start time of The format is "HH-
day reversion. MM"
sunday-todr-period INT Sunday time of day
(5-300 Default=20) reversion period.
thursday-enable YES Time of day reversion
profile is enabled on
Thursday.
NO Time of day reversion
profile is disabled on
Thursday.
thursday-todr time Thursday start time of The format is "HH-
day reversion. MM"
thursday-todr-period INT Thursday time of day
(5-300 Default=20) reversion period.
tuesday-enable YES Time of day reversion
profile is enabled on
Tuesday.
NO Time of day reversion
profile is disabled on
Tuesday.
tuesday-todr time Tueday start time of The format is "HH-
day reversion. MM"
tuesday-todr-period INT Tuesday time of day
(5-300 Default=20) reversion period.
wednesday-enable YES Time of day reversion
profile is enabled on
Wednesday.
NO Time of day reversion
profile is disabled on
Wednesday.
wednesday-todr time Wednesday start time The format is "HH-
of day reversion. MM"
wednesday-todr-period INT Wednesday time of
(5-300 Default=20) day reversion period.
AID Descriptions
AID Type Format Values
OSRP Link Aggregation OSRPLAG-shelf-id OSRPLAG-[0..992]-[1..255]
Group AID
Input Parameter Description
Parameter Value Description Notes
label string Label for the
( min len=0 max len=64 ) OSRPLAG.
AID Descriptions
AID Type Format Values
OSRP Link Aggregation OSRPLAG-shelf-id OSRPLAG-[0..992]-[1..255]
Group AID
Input Parameter Description
Parameter Value Description Notes
label string Label for the
( min len=0 max len=64 ) OSRPLAG.
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
conn-type 1WAY Unidirectional
Connection
1WAYPR Unidirectional Path
Ring Connection
2WAY Bidirectional
Connection
2WAYPR Bidirectional Path Ring
Connection
2WAYDPR Bidirectional Single
Homed Path Ring
Connection
ckt-id string Circuit Identifier - can
be used to hold the
CLCI (see GR-199).
dswmate ODU CTP ODUCTP- ODUCTP- Path Protection
(6500- shelf- [0..992]- Destination Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
port- 4]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
portSsub [1..5]S[1..4
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
sw-mate ODU CTP ODUCTP- ODUCTP- Path Protection Switch
(6500- shelf- [0..992]- Mate. Specifies the
T12) slot- [1..12]- switch mate path
port- [1..40]- endpoint used as the
[2,2E,3,4,F protection input signal
rt1Ptp1
,C2,C4,CN for the fromaid.
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [2,4,C2,C4
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,F,C2,C4,CN]P[1]
rt1Ptp1
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
conn-type 1WAY Unidirectional
Connection
1WAYPR Unidirectional Path
Ring Connection
2WAY Bidirectional
Connection
2WAYPR Bidirectional Path Ring
Connection
2WAYDPR Bidirectional Single
Homed Path Ring
Connection
dswmate ODU CTP ODUCTP- ODUCTP- Path Protection
(6500- shelf- [0..992]- Destination Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [3,C2,C4,C
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
port- 4]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
port- [4]P[1]-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
sw-mate ODU CTP ODUCTP- ODUCTP- Path Protection Switch
(6500- shelf- [0..992]- Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
portSsub [1..5]S[1..4
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-ALL [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-ALL [2,4,C2,C4,CN]P[1]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-port-ALL ODUCTP-[0..992]-[1..12]-[1..40]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot-ALL ODUCTP-[0..992]-[1..12]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-ALL [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-ALL [2,4,C2,C4,CN]P[1]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-port-ALL ODUCTP-[0..992]-[1..24]-[1..40]-ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot-ALL ODUCTP-[0..992]-[1..24]-ALL
ODU CTP ODUCTP-shelf-ALL ODUCTP-[0..992]-ALL
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-ALL ALL
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
conn-type 1WAY Unidirectional
Connection
1WAYPR Unidirectional Path
Ring Connection
2WAY Bidirectional
Connection
2WAYPR Bidirectional Path Ring
Connection
2WAYDPR Bidirectional Single
Homed Path Ring
Connection
ckt-id string Circuit Identifier - can
be used to hold the
CLCI (see GR-199).
dswmate ODU CTP ODUCTP- ODUCTP- Path Protection
(6500- shelf- [0..992]- Destination Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
sw-mate ODU CTP ODUCTP- ODUCTP- Path Protection Switch
(6500- shelf- [0..992]- Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) [1..12]S[1..
slotSsub
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1-,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
port- [F,2,2E,3,4
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
Syntax Definition
Parameter Attributes Description Notes
fromaid M aid
toaid M aid
conn-type O Cross-Connect Type
ckt-id M Circuit Identifier - can
be used to hold the
CLCI (see GR-199).
dswmate O Path Protection
Destination Mate.
fccid O FCC Identifier for
OSMINE created
FCCs.
owner M Owner Type.
sw-mate O Path Protection Switch
Mate.
AID Descriptions
AID Type Format Values
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..12]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1 [2,2E,3,4,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [3,C2,C4,CN]P[1]-[0,1,2,2E,4,F]P[1..32]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2 [4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [4,C2,C4,CN]P[1]-
[2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot-port- ODUCTP-[0..992]-[1..24]-[1..40]-
rt1Ptp1-rt2Ptp2-rt3Ptp3- [4,C2,C4,CN]P[1]-
rt4Ptp4 [2,4,C2,C4,CN]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]-
[0,1,2,2E,3,4,F]P[1..32]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..12]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1 [2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slot- ODUCTP-[0..992]-[1..24]-[1..40]S[1..4]-
portSsubport-rt1Ptp1-rt2Ptp2 [2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1..12]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,F,C2,C4,CN]P[1]
ODU CTP (6500-T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..8]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1 [F,2,2E,3,4]P[1]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [2,2E,3,3E2,4,C2,C4,CN]P[1]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [4]P[1]-[2]P[1..80]-[0,1,F]P[1..80]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[F,2,2E,3,4]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[F,2,2E,3,4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T12) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..12]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[F,2,2E,3,4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2 [CN]P[1]-[4]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[4]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
ODU CTP (6500 - T24) ODUCTP-shelf-slotSsubslot- ODUCTP-[0..992]-[1..24]S[1..3]-[1..12]-
port-rt1Ptp1-rt2Ptp2-rt3Ptp3- [CN]P[1]-[4]P[1..100]-
rt4Ptp4 [0,1,2,2E,3,3E2,4,F]P[1..100]-
[0,1,2,2E,3,3E2,4,F]P[1..100]
Input Parameter Description
Parameter Value Description Notes
conn-type 1WAY Unidirectional
Connection
1WAYPR Unidirectional Path
Ring Connection
2WAY Bidirectional
Connection
2WAYPR Bidirectional Path Ring
Connection
2WAYDPR Bidirectional Single
Homed Path Ring
Connection
ckt-id string Circuit Identifier - can
be used to hold the
CLCI (see GR-199).
dswmate ODU CTP ODUCTP- ODUCTP- Path Protection
(6500- shelf- [0..992]- Destination Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [3,C2,C4,C
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
port- 4]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub[1..12]S[1..
slot- 3]-[1..12]-
port- [2,2E,3,3E
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
port- [4]P[1]-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
sw-mate ODU CTP ODUCTP- ODUCTP- Path Protection Switch
(6500- shelf- [0..992]- Mate.
T12) slot- [1..12]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
port- [1..40]-
rt1Ptp1- [4,C2,C4,C
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,2E,3,4,F
rt1Ptp1
,C2,C4,CN
]P[1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[3,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,4
,F]P[1..32]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8
0]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3 ,CN]P[1..8
0]-
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
port- [1..40]-
[4,C2,C4,C
rt1Ptp1-
N]P[1]-
rt2Ptp2-
[2,4,C2,C4
rt3Ptp3- ,CN]P[1..8
rt4Ptp4 0]-
[0,1,2,2E,3
,4,F]P[1..3
2]-
[0,1,2,2E,3
,4,F]P[1..3
2]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slot- [1..12]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,2E,F,C2
rt1Ptp1
,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slot- [1..24]-
portSsub [1..40]S[1..
4]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1- ,CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1..12]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T12) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,2E,F,C2
rt1Ptp1 ,C4,CN]P[
1]
ODU CTP ODUCTP- ODUCTP-
(6500- shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-
[1..5]S[1..4
portSsub
]-
port-
[2,4,C2,C4
rt1Ptp1-
,CN]P[1]-
rt2Ptp2
[0,1,2,2E,3
,4,F]P[1..8]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[F,2,2E,3,4
port-
]P[1]
rt1Ptp1
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..24]S[1..
slot- 3]-[1..12]-
[2,2E,3,3E
port-
2,4,C2,C4,
rt1Ptp1-
CN]P[1]-
rt2Ptp2 [0,1,2,2E,3
,3E2,4,F]P
[1..100]
ODU CTP ODUCTP- ODUCTP-
(6500 - shelf- [0..992]-
T24) slotSsub [1..12]S[1..
slot- 3]-[1..12]-
[4]P[1]-
port-
[2]P[1..80]-
rt1Ptp1-
[0,1,F]P[1..
rt2Ptp2- 80]
rt3Ptp3
OTS
topology ots show Retrieve the OTS attributes.
topology ots set Edit the OTS Object attributes.
topology ots create Create the OTS Object
topology ots delete Delete an OTS Object.
port wavelength rules show Retrieve the OTS wavelength provisioning rules.
OTS-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL OTS OTS-shelf-ALL OTS-[0..992]-ALL
OTS-[0..992]-ALL
OTSALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
otsaid M aid n/a
act-ctrlmode O Actual CONTROL
MODE for OTS.
amp-mate O OTS-shelf-instance n/a
associated-ots O Associated OTS The discovered
associated OTS in the
format tid-shelf-
instance
auto-gb O Auto-Guardbanding
flag to allow the
opacity settings on
available, unmanaged
channels.
auto-mux-pout O Automatic MUX Power Derived target power
Output output calculated using
the power ratio. The
value will be of the
format "xx.xx" and
dBm will be assumed.
auto-mux-pout-ratio O Automatic MUX Power User-provisionable
Output Ratio MUX power output
ratio used to calculate
the automatic power.
auto-route O Autoroute
bun-factor O Bun Factor
bw-cal O Backward Calibration
cfgtype M Configuration Type
ch-bias-ramp O Channel Bias Ramp User-provisionable
Gradient channel bias ramp
used to provide an
additional amount of
bias based on the
wavelength
combined-opm-power O Sets the
CombinedOpmPower
value for channels
created in this OTS.
When
CombinedOpmPower
is enabled, the CMD44
optmon power reading
are combined and
treated as a single
reading. DOC and
WSS controller take
this combined and
scaled OPM power
reading into account
for input source power
profile instead of the
default scaled power
estimates.
cps O CPS Parameter
cs-ind M Coherent Select
Indicator
ctrlcpbl O Capable CONTROL
MODE for OTS.
doc-ind M Is this a DOC end
enhanced-topology O Enhanced Topology
gb-width O Guard Band Width
lim O LIM-shelf-slot Line-facing LIM
line-in O EQPT-shelf-slot-port n/a
line-out O EQPT-shelf-slot-port n/a
min-mux-pout O Minimum MUX Power User-provisionable
Output minimum target power
output for calculating
forecast-tolerant loss.
The value will be of the
format "xx.xx" and
dBm will be assumed.
This value is indicated
by the value of the
OTS REFBW
parameter.
olf-osc-only O Flag used to clear
ALSO solely based on
the OSC LOF
condition .
osc O OSC-shelf-slot-port n/a
osc-required O OSC Required Set to FALSE when
the OSC is not
required (e.g.
Stretched Span or
Submarine Terminal)
osid O The Optical System ID maximum length of 8
characters
pepc-clamp O PEPC CLAMP
indicates whether this
algorithm is enabled or
disabled.
prov-associated-ots O Associated OTS The provisioned
associated OTS in the
format tid-shelf-
instance
prov-ctrlmode O User provisioned
CONTROL MODE for
OTS.
refbw O OTS MINMUXPOUT
parameter's resolution
bandwidth
rxlabel O Provisioned OMS RX maximum length of 64
link identifier characters
rx-path M RX Path ID value
seq-chc-updates O Sequence CHC
Updates
slot-cfg-mode O Slot Configuration
Mode indicates how
the Slot Data is
generated in the OTS.
When it is set to
PROIVISIONED, it
means the Slot Data is
provisioned in the OTS
via TL1 command. If it
is set to DERIVED,
then it indicates that
the Slot Data is auto-
populated by other
application.
subtype O Configuration Subtype
txlabel O Provisioned OMS TX maximum length of 64
link identifier characters
tx-path M TX Path ID value
unexpt-loss-thres O WSS UnExpected User-provisionable
Loss Threshold WSS loss threshold.
The value will be of the
format "xx.xx" and dB
will be assumed.
wss O WSSOPM-shelf-slot n/a
AID Descriptions
AID Type Format Values
OTS identifier OTS-shelf-instance OTS-[0..992]-[1..8]
Input Parameter Description
Parameter Value Description Notes
amp-mate OTS OTS- OTS- OTS-shelf-instance instance = 1-4
identifier shelf- [0..992]-
instance [1..8]
auto-gb DISABLE
ENABLE
auto-mux-pout-ratio DECIMAL Automatic MUX Power User-provisionable
(0.00-1.00 Default=0.33) Output Ratio MUX power output
ratio used to calculate
the automatic power.
auto-route DISABLE
ENABLE
bun-factor DECIMAL Bun Factor
(0.00-200.00 Default=0.00)
bw-cal DISABLE
ENABLE
cfgtype AMP Amplifier Configuration
CHA Channel Access
Configuration
ch-bias-ramp DECIMAL Channel Bias Ramp User-provisionable
(0.00-2.00 Default=0.00) Gradient channel bias ramp
used to provide an
additional amount of
bias based on the
wavelength
combined-opm-power DISABLE
ENABLE
cps DISABLE
ENABLE
cs-ind N Not a Coherent Select
OTS.
Y OTS in Coherent
Select mode.
doc-ind Y
N
enhanced-topology DISABLE
ENABLE
gb-width INT Guard Band Width
(0-500 Default=0)
min-mux-pout DECIMAL Minimum MUX Power User-provisionable
(-30.00-15.00 Default=15.00) Output minimum target power
output for calculating
forecast-tolerant loss.
The value will be of the
format "xx.xx" and
dBm will be assumed.
This value is indicated
by the value of the
OTS REFBW
parameter.
olf-osc-only DISABLE
ENABLE
osc RLA OSC OSC- OSC- OSC-shlef-slot-port slot=1-14, port = 1-2
(6500- shelf- [0..992]-
T12) slot- [1..12]-[2]
port
RLA OSC OSC- OSC-
(6500- shelf- [0..992]-
T24) slot- [1..24]-[2]
port
osc-required TRUE
FALSE
osid string The Optical System ID maximum length of 8
( min len=0 max len=8 ) characters
pepc-clamp DISABLE
ENABLE
prov-associated-ots ident Associated OTS The associated OTS in
the format tid-shelf-
instance
prov-ctrlmode 50 50GHz resolution
bandwidth; ITU fixed
grid.
12.5 12.5GHz resolution This value is
bandwidth. supported only on SP2
and SPAP2 platforms.
refbw 50GHZITU 50GHz ITU
12.5GHZ 12.5GHz
rxlabel string Provisioned OMS RX maximum length of 64
( min len=0 max len=64 ) link identifier characters
seq-chc-updates DISABLE
ENABLE
subtype AMP Line Amplifier
ROADM Reconfigurable OADM
TOADM Thin OADM
DIOADM Direction Independent
OADM
COADM Colourless OADM
PASSIVE Passive OADM or Line
Amplifer
txlabel string Provisioned OMS TX maximum length of 64
( min len=0 max len=64 ) link identifier characters
tx-path INT TX Path ID value
(1-254)
unexpt-loss-thres DECIMAL WSS UnExpected User-provisionable
(0.00-10.00 Default=6.50) Loss Threshold WSS loss threshold.
The value will be of the
format "xx.xx" and dB
will be assumed.
OTS-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL OTS OTS-shelf-ALL OTS-[0..992]-ALL
OTS-[0..992]-ALL
OTSALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
otsaid M aid n/a
permit M L Wavelength
Provisioning Rules
wl M Wavelength
Output Parameter Description
Parameter Value Description Notes
otsaid ident aid n/a
permit NONE Wavelength cannot be
provisioned on this
OTS.
PASSTHROUGH Wavelength supports
passthrough
provisioning on this
OTS.
ADD Wavelength supports
local add provisioning
on this OTS.
DROP Wavelength supports
local drop provisioning
on this OTS.
BLOCKED Wavelength is blocked
on this OTS.
wl INT Wavelength
(152877-156672)
Operational Measurements
om wan reset Initialize Operational Measurement: This command allows user to initialize one or more
operational measurement counters associated with specific entities in the NE.
om wan counts show Retrieve Operational Measurement: This command allows you to retrieve one or more
operational measurement counters associated with specific entities in the NE.
om ettp init Initialise Operation Measurement - Ethernet: this command is used to clear the 64-bit
operational measurement counters for Ethernet client ports.
om ettp counts show Retrieve Operation Measurement - Ethernet: this command retrieves the 64-bit
operational mesaurement counters for Ethernet client ports.
AID Descriptions
AID Type Format Values
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2,101..228]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..4]
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..2]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[101..104]
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[101..104]
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[101..104]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
omtype INFRAMES Total WAN frames Received from
received backplane, towards
LAN Egress port
INFRAMESERR Total WAN frames Includes GFP FCS
received with errors and uncorrectable
tHec errors
INDFR Total WAN frames Includes frames with
received with no FCS unknown/invalid VID
errors that are
discarded
OUTDFR Total Egress direction
WAN frames discarded
INOCTETS Count of Bytes
contained in
INFRAMES
INOCTETSERR Count of Bytes
contained in
INFRAMESERR
OUTFRAMES Total WAN frames Transmitted towards
transmitted backplane, from LAN
Ingress port
OUTOCTETS Count of Bytes
contained in
OUTFRAMES
TTLDFR Total received frames
discarded due to zero
(0) Time To Live (TTL)
FRTOOSHORTS Frames discarded with
less than allowable
octet count with correct
FCS
FRTOOLONGS Frames discarded that
exceed allowable MTU
with a valid FCS
HECDFR Received frames
discarded due to HEC
error
FCSERR Received frames
discarded due to FCS
error
SSUDFR Received frames
discarded that were
Self Source Unicast
frames
PMDAFR Received frames (PHY
to MAC) that were
aborted by the PMD
BADFR Received frames
discarded due to an
incorrect or
unrecognized Source
Address
BPDFR Total received frames
discarded due to Parity
Error
SCFFFR Total received (PHY to
MAC) errored SCFF
frames discarded, with
bad parity, bad SCf, or
both
INFILTFR Total frames received
that are discarded due
to filtering
OUTFILTFR Total frames discarded
on transmission due to
filtering
INPEERCFR Total peered control
frames received
INTUNCFR Total tunneled control
frames received
INDCFR Total control frames
received and
discarded
INFRCNF Total Conforming
Layer 2 traffic frames
received
INFRNC Total Non-conforming
frames received
INOCTNC Total octet count of
Non-Conforming Layer
2 traffic frames
received
INOCTCNF Total octet count of
Conforming Layer 2
traffic frames received
INFRGRNC Total Non Conforming
Layer 2 traffic frames
received
INOCTGRNC Total octet count of
Grossly Non
Conforming Layer 2
traffic frames received
INTERNALERRDFR In Frames: Data Error
INMACDADFR In Frames: MAC
Dropped
OUTFRAMESERR Counts the total
number of frames that
could not be
transmitted because of
errors
ALL-RPR All applicable RPR
omtypes
ALL All applicable omtypes valid only as an input
parameter
ALL-IF All applicable Generic valid only as an input
interface omtypes parameter
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..4]
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..2]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[2]
WAN-[0..992]-ALL
WAN port on 10GOTR card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[101..104]
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[101..104]
WAN-[0..992]-ALL
WAN port on RPR card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[101..104]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on FLEXMOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
omtype INFRAMES Total WAN frames Received from
received backplane, towards
LAN Egress port
INFRAMESERR Total WAN frames Includes GFP FCS
received with errors and uncorrectable
tHec errors
INDFR Total WAN frames Includes frames with
received with no FCS unknown/invalid VID
errors that are
discarded
OUTDFR Total Egress direction
WAN frames discarded
INOCTETS Count of Bytes
contained in
INFRAMES
INOCTETSERR Count of Bytes
contained in
INFRAMESERR
OUTFRAMES Total WAN frames Transmitted towards
transmitted backplane, from LAN
Ingress port
OUTOCTETS Count of Bytes
contained in
OUTFRAMES
TTLDFR Total received frames
discarded due to zero
(0) Time To Live (TTL)
FRTOOSHORTS Frames discarded with
less than allowable
octet count with correct
FCS
FRTOOLONGS Frames discarded that
exceed allowable MTU
with a valid FCS
HECDFR Received frames
discarded due to HEC
error
FCSERR Received frames
discarded due to FCS
error
SSUDFR Received frames
discarded that were
Self Source Unicast
frames
PMDAFR Received frames (PHY
to MAC) that were
aborted by the PMD
BADFR Received frames
discarded due to an
incorrect or
unrecognized Source
Address
BPDFR Total received frames
discarded due to Parity
Error
SCFFFR Total received (PHY to
MAC) errored SCFF
frames discarded, with
bad parity, bad SCf, or
both
INFILTFR Total frames received
that are discarded due
to filtering
OUTFILTFR Total frames discarded
on transmission due to
filtering
INPEERCFR Total peered control
frames received
INTUNCFR Total tunneled control
frames received
INDCFR Total control frames
received and
discarded
INFRCNF Total Conforming
Layer 2 traffic frames
received
INFRNC Total Non-conforming
frames received
INOCTNC Total octet count of
Non-Conforming Layer
2 traffic frames
received
INOCTCNF Total octet count of
Conforming Layer 2
traffic frames received
INFRGRNC Total Non Conforming
Layer 2 traffic frames
received
INOCTGRNC Total octet count of
Grossly Non
Conforming Layer 2
traffic frames received
INTERNALERRDFR In Frames: Data Error
INMACDADFR In Frames: MAC
Dropped
OUTFRAMESERR Counts the total
number of frames that
could not be
transmitted because of
errors
ALL-RPR All applicable RPR
omtypes
ALL All applicable omtypes valid only as an input
parameter
ALL-IF All applicable Generic valid only as an input
interface omtypes parameter
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
wanfacility M aid
bpdfr O Total received frames
discarded due to Parity
Error.
fcserr O Receive frames
discarded due to FCS
error
frtoolongs O Frames discarded that
exceed allowable MTU
with a valid FCS
frtooshorts O Frames discarded with
less than allowable
octet count with correct
FCS.
hecdfr O Received frames
discarded due to HEC
error
indcfr O Total control frames
received and
discarded
indfr O Total WAN frames
received with no FCS
errors that are
discarded
infiltfr O Total frames received
that are discarded due
to filtering
inframes O Total WAN frames
received
inframeserr O Total WAN frames
received with errors
infrcnf O Total Conforming
Layer 2 traffic frames
received
infrgrnc O Total Non Conforming
Layer 2 traffic frames
received
infrnc O Total Non-conforming
frames received
inmacdadfr O In Frames: MAC
Dropped
inoctcnf O Total octet count of
Conforming Layer 2
traffic frames received
inoctets O Count of Bytes
contained in
INFRAMES
inoctetserr O Count of Bytes
contained in
INFRAMESERR
inoctgrnc O Total octet count of
Grossly Non
Conforming Layer 2
traffic frames received
inoctnc O Total octet count of
Non-Conforming Layer
2 traffic frames
received
inpeercfr O Total peered control
frames received
internalerrdfr O In Frames: Data Error
intuncfr O Total tunneled control
frames received
outdfr O Total Egress direction
WAN frames discarded
outfiltfr O Total frames discarded
on transmission due to
filtering
outframes O Total WAN frames
transmitted
outframeserr O ICounts the total
number of frames that
could not be
transmitted because of
errors
outoctets O Count of Bytes
contained in
OUTFRAMES
pmdafr O Received frames (PHY
to MAC) that were
aborted by the PMD.
scfffr O Total received (PHY to
MAC) errored SCFF
frames discarded, with
bad parity, bad SCf, or
both.
ssudfr O Received frames
discarded that were
Self Source Unicast
frames.
ttldfr O Total received frames
discarded due to zero
(0) Time To Live (TTL)
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
omtype FCSERR
FRTOOSHORTS Frames less than 64
bytes in length with
valid FCS
FRTOOLONGS Frames that exceed
the MTU with valid
FCS
SYMBOLERR Coding errors received
INPAUSEFR Pause frames received
OUTPAUSEFR Total ETH pause
frames transmitted
INFRAMES Total frames received
INFRAMESERR Total ETH frames
received with FCS
errors
INFRAMESDISCDS Count of ingress
Frames discarded due
to FIFO overflow
INDFR Total ETH RX frames Generic catch all
discarded for reasons counter which includes
other than FCS errors all discarded
frames.This counter
would include
INFRAMESDISCDS,
FRTOOSHORTS,
FRTOOLONGS, etc.
INOCTETS Count of Bytes
contained in
INFRAMES
OUTFRAMES Total ETH frames
transmitted
OUTFRAMESERR Total ETH frames
transmitted with errors
OUTFRAMESDISCDS Total Egress direction
frames discarded due
to congestion &FIFO
overflow
OUTOCTETS Octets in frames
counted by
OUTFRAMES
OUTDFR Total ETH TX frames Generic catch all
discarded counter which includes
all discarded frames
FRAG Undersized frames
with FCS errors
JAB Oversized frames with
FCS errors
ALL-IF All applicable Generic valid only as an input
interface omtypes parameter
ALL-ETH All applicable Ethernet valid only as an input
specific omtypes parameter
ALL All applicable valid only as an input
montypes parameter
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
omtype FCSERR
FRTOOSHORTS Frames less than 64
bytes in length with
valid FCS
FRTOOLONGS Frames that exceed
the MTU with valid
FCS
SYMBOLERR Coding errors received
INPAUSEFR Pause frames received
OUTPAUSEFR Total ETH pause
frames transmitted
INFRAMES Total frames received
INFRAMESERR Total ETH frames
received with FCS
errors
INFRAMESDISCDS Count of ingress
Frames discarded due
to FIFO overflow
INDFR Total ETH RX frames Generic catch all
discarded for reasons counter which includes
other than FCS errors all discarded
frames.This counter
would include
INFRAMESDISCDS,
FRTOOSHORTS,
FRTOOLONGS, etc.
INOCTETS Count of Bytes
contained in
INFRAMES
OUTFRAMES Total ETH frames
transmitted
OUTFRAMESERR Total ETH frames
transmitted with errors
OUTFRAMESDISCDS Total Egress direction
frames discarded due
to congestion &FIFO
overflow
OUTOCTETS Octets in frames
counted by
OUTFRAMES
OUTDFR Total ETH TX frames Generic catch all
discarded counter which includes
all discarded frames
FRAG Undersized frames
with FCS errors
JAB Oversized frames with
FCS errors
ALL-IF All applicable Generic valid only as an input
interface omtypes parameter
ALL-ETH All applicable Ethernet valid only as an input
specific omtypes parameter
ALL All applicable valid only as an input
montypes parameter
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
ettp M aid
fcs-error O Counts the number of
frames received on a
particular interface that
are an integral number
of octets in length and
do not pass the FCS
check
frag O Applicable only for
LAN/FC, where is it the
number of 10B_ERR
code transmitted.
Value is always zero
for LAN/ETH,
WAN/GFP-F,
WAN/POS and
WAN/GFP-T.
frames-too-long O Counts the number of
frames received on a
particular interface that
exceed the maximum
permitted frame size
frames-too-short O Counts the number of
frames received that
are smaller than the
permitted 64-byte
frame size
in-discard-frame O Counts the number of
Ethernet frames too
short (<64 bytes) with
an FCS error
in-frames O Counts the total
number of frames
received on that
interface (including
errored frames)
in-frames-discard O Counts the total
number of received
frames that were
chosen to be
discarded even though
no errors had been
detected to prevent
their delivery
in-frames-error O Counts the total
number of errored
frames received on
that interface
in-octets O Counts the total
number of received
octets (includes octets
from both OK and
errored frames)
in-pause-frames O Counts the number of
MAC control frames
received with an
opcode indicating a
PAUSE frame
jab O Counts the number of
Ethernet frames too
long (>MTU) with an
FCS error
out-discard-frames O Total TX frames
discarded
out-discard-frames- O Counts the total
congestion number of frames that
were chosen to be
discarded even though
no errors had been
detected to prevent
their delivery
out-frames O Counts the total
number of transmitted
frames on that
interface (including
errored frames)
out-frames-error O Counts the total
number of frames that
could not be
transmitted because of
errors
out-octets O Counts the total
number of transmitted
octets (includes octets
from both OK and
errored frames)
out-pause-frames O Counts the number of
MAC control frames
transmitted with an
opcode indicating a
PAUSE frame
symbol-error O Counts the number of
GMII data reception
errors
Output Parameter Description
Parameter Value Description Notes
aidtype ETTP AID type
ettp ident aid
fcs-error INT Counts the number of
(0-4294967295) frames received on a
particular interface that
are an integral number
of octets in length and
do not pass the FCS
check
frag INT Applicable only for
(0-4294967295) LAN/FC, where is it the
number of 10B_ERR
code transmitted.
Value is always zero
for LAN/ETH,
WAN/GFP-F,
WAN/POS and
WAN/GFP-T.
frames-too-long INT Counts the number of
(0-4294967295) frames received on a
particular interface that
exceed the maximum
permitted frame size
frames-too-short INT Counts the number of
(0-4294967295) frames received that
are smaller than the
permitted 64-byte
frame size
in-discard-frame INT Counts the number of
(0-4294967295) Ethernet frames too
short (<64 bytes) with
an FCS error
in-frames INT Counts the total
(0-4294967295) number of frames
received on that
interface (including
errored frames)
in-frames-discard INT Counts the total
(0-4294967295) number of received
frames that were
chosen to be
discarded even though
no errors had been
detected to prevent
their delivery
in-frames-error INT Counts the total
(0-4294967295) number of errored
frames received on
that interface
in-octets INT Counts the total
(0-4294967295) number of received
octets (includes octets
from both OK and
errored frames)
in-pause-frames INT Counts the number of
(0-4294967295) MAC control frames
received with an
opcode indicating a
PAUSE frame
jab INT Counts the number of
(0-4294967295) Ethernet frames too
long (>MTU) with an
FCS error
out-discard-frames INT Total TX frames
discarded
out-discard-frames- INT Counts the total
congestion (0-4294967295) number of frames that
were chosen to be
discarded even though
no errors had been
detected to prevent
their delivery
out-frames INT Counts the total
(0-4294967295) number of transmitted
frames on that
interface (including
errored frames)
out-frames-error INT Counts the total
(0-4294967295) number of frames that
could not be
transmitted because of
errors
out-octets INT Counts the total
(0-4294967295) number of transmitted
octets (includes octets
from both OK and
errored frames)
out-pause-frames INT Counts the number of
(0-4294967295) MAC control frames
transmitted with an
opcode indicating a
PAUSE frame
symbol-error INT Counts the number of
(0-4294967295) GMII data reception
errors
AID Descriptions
AID Type Format Values
OCH AIDs (6500 7-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slot-port- OCH-[0..992]-[1..8,83..86,91..99]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..8,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..14,83..99]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..14,83..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..99]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-port- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[51..82]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[51..82]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500-T12) OCH-shelf-slot-port- OCH-[0..992]-[1..12]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T12) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..12]-S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..12]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..12]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
OCH AIDs (6500-T24) OCH-shelf-slot-port- OCH-[0..992]-[1..24]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T24) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..24]-[1..24]S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..24]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..24]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
AID Descriptions
AID Type Format Values
OCH AIDs (6500 7-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slot-port- OCH-[0..992]-[1..8,83..86,91..99]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..8,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..14,83..99]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..14,83..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..99]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-port- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[51..82]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[51..82]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500-T12) OCH-shelf-slot-port- OCH-[0..992]-[1..12]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T12) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..12]-S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..12]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..12]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
OCH AIDs (6500-T24) OCH-shelf-slot-port- OCH-[0..992]-[1..24]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T24) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..24]-[1..24]S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..24]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..24]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
AID Descriptions
AID Type Format Values
OCH AIDs (6500 7-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..7,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slot-port- OCH-[0..992]-[1..8,83..86,91..99]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..8,83..86,91..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) wavelength [1..192]-[0..999999]
OCH AIDs (6500 7 PKT- OCH-shelf-slotSsubslot- OCH-[0..992]-[83..86,91..99]S[1..6]-
OPT) portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-port- OCH-[0..992]-[1..14,83..99]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..14,83..99]-
wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[83..99]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 14-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[83..99]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-port- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slot-portSsubport- OCH-[0..992]-
wavelength [1..8,11..18,21..28,31..38,51..82]-
[1..192]S[1..88]-[0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[51..82]S[1..6]-[1..192]-
wavelength [0..999999]
OCH AIDs (6500 32-Slot) OCH-shelf-slotSsubslot- OCH-[0..992]-[51..82]S[1..6]-
portSsubport-wavelength [1..192]S[1..88]-[0..999999]
OCH AIDs (6500-T12) OCH-shelf-slot-port- OCH-[0..992]-[1..12]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T12) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..12]-S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..12]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T12) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..12]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
OCH AIDs (6500-T24) OCH-shelf-slot-port- OCH-[0..992]-[1..24]-[1..24]-[0..999999]
wavelength
OCH AIDs (6500-T24) OCH-shelf-slot-portSsubport- OCH-[0..992]-[1..24]-[1..24]S[1..88]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot-port- OCH-[0..992]-[1..24]S[1..4]-[1..24]-
wavelength [0..999999]
OCH AIDs (6500-T24) OCH-shelf-slotSsubslot- OCH-[0..992]-[1..24]S[1..4]-
portSsubport-wavelength [1..24]S[1..88]-[0..999999]
Input Parameter Description
Parameter Value Description Notes
dlt-time-window INT Maximum waiting time
(0-3600 Default=0) in seconds for DOC
managed channel to
become unmanaged
so that the CRS can
be deleted.
AID Descriptions
AID Type Format Values
Media Channel Trail MCTTP-shelf-slot-port-mcId MCTTP-[0..992]-[1..6]-[5,8]-
Termination Point (6500 7- [1..3000,152877,152916,152955...1530
Slot) 72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]
Media Channel Trail MCTTP-shelf-slot-port-mcId MCTTP-[0..992]-[1..8]-[5,8]-
Termination Point (6500 7 [1..3000,152877,152916,152955...1530
PKT-OPT) 72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]
Media Channel Trail MCTTP-shelf-slot-port-mcId MCTTP-[0..992]-[1..6,9..14]-[5,8]-
Termination Point (6500 [1..3000,152877,152916,152955...1530
14-Slot) 72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]
Media Channel Trail MCTTP-shelf-slot-port-mcId MCTTP-[0..992]-
Termination Point (6500 [1..8,11..18,21..28,31..38]-[5,8]-
32-Slot) [1..3000,152877,152916,152955...1530
72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]
Media Channel Trail MCTTP-shelf-slot-port-mcId MCTTP-[0..992]-[1..12]-[5,8]-
Termination Point (6500- [1..3000,152877,152916,152955...1530
T12) 72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]
Input Parameter Description
Parameter Value Description Notes
connection-type 1WAY Unidirectional MC
2WAY Bidirectional MC
1WAYBLOCKED Unidirectional blocked
spectrum. Cross-
connections cannot
use this spectral
range.
2WAYBLOCKED Bidirectional blocked
spectrum. Cross-
connections cannot
use this spectral
range.
auto-delete TRUE Auto delete the
MCTTP when all its
associated NMC
cross-connects are
deleted.
FALSE Auto delete disabled.
cc-mode MODE1
MODE2
MODE3
max-freq DECIMAL Maximum Frequency
(186.325000-190.975000, in THz. The frequency
191.325000-196.125000) will be in format of
"xxx.xxxxxx".
max-freq-deadband DECIMAL Upper dead band in
(0.000-4800.000 Default=6.250) GHz. The dead band
will be in format of
"xxxx.xxx".
mc-bias DECIMAL MC Bias correction in
(-10.00-10.00 Default=0.00) dB. The bias will be in
format of "+-xx.xx".
min-freq DECIMAL Minimum Frequency in
(186.325000-190.975000, THz. The frequency
191.325000-196.125000) will be in format of
"xxx.xxxxxx".
min-freq-deadband DECIMAL Lower dead band in
(0.000-4800.000 Default=6.250) GHz. The dead band
will be in format of
"xxxx.xxx".
AID Descriptions
AID Type Format Values
Network Media Channel NMCLNCTP-shelf-slot-port- NMCLNCTP-[0..992]-[1..6]-[5,8]-
Line Connection mcId-nmcId [1..3000,152877,152916,152955...1530
Termination Point (6500 7- 72,153112,153151,153190...153307,15
Slot) 3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]-[1..1024]
Network Media Channel NMCLNCTP-shelf-slot-port- NMCLNCTP-[0..992]-[1..8]-[5,8]-
Line Connection mcId-nmcId [1..3000,152877,152916,152955...1530
Termination Point (6500 7 72,153112,153151,153190...153307,15
PKT-OPT) 3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]-[1..1024]
Network Media Channel NMCLNCTP-shelf-slot-port- NMCLNCTP-[0..992]-[1..6,9..14]-[5,8]-
Line Connection mcId-nmcId [1..3000,152877,152916,152955...1530
Termination Point (6500 72,153112,153151,153190...153307,15
14-Slot) 3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]-[1..1024]
Network Media Channel NMCLNCTP-shelf-slot-port- NMCLNCTP-[0..992]-
Line Connection mcId-nmcId [1..8,11..18,21..28,31..38]-[5,8]-
Termination Point (6500 [1..3000,152877,152916,152955...1530
32-Slot) 72,153112,153151,153190...153307,15
3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]-[1..1024]
Network Media Channel NMCLNCTP-shelf-slot-port- NMCLNCTP-[0..992]-[1..12]-[5,8]-
Line Connection mcId-nmcId [1..3000,152877,152916,152955...1530
Termination Point (6500- 72,153112,153151,153190...153307,15
T12) 3347,153386,153425,153464,153504,1
53543,153582,153622,153661,153700,
153740,153779,153819,153858,15389
8,153937,153977,154016,154056,1540
95,154135,154175,154214,154254,154
294,154333,154373,154413,154453,15
4492,154532,154572...154772,154811,
154851,154891,154932,154972,15501
2...155252,155293,155333,155373,155
413,155454,155494,155534,155575,15
5615,155655,155696,155736,155777,1
55817,155858,155898,155939,155979,
156020,156061,156101,156142,15618
3,156223,156264,156305,156345,1563
86,156427...156550,156590,156631,15
6672]-[1..1024]
Network Media Channel NMCADCTP-shelf-slot-port- NMCADCTP-[0..992]-
Add/Drop Connection nmcId [1..7,83..86,91..99]-[1..192]-[1..1024]
Termination Point (6500 7-
Slot)
Network Media Channel NMCADCTP-shelf-slot- NMCADCTP-[0..992]-
Add/Drop Connection portSsubport-nmcId [1..7,83..86,91..99]-[1..192]S[1..192]-
Termination Point (6500 7- [1..1024]
Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-
Add/Drop Connection port-nmcId [83..86,91..99]S[1..6]-[1..192]-[1..1024]
Termination Point (6500 7-
Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-
Add/Drop Connection portSsubport-nmcId [83..86,91..99]S[1..6]-[1..192]S[1..192]-
Termination Point (6500 7- [1..1024]
Slot)
Network Media Channel NMCADCTP-shelf-slot-port- NMCADCTP-[0..992]-
Add/Drop Connection nmcId [1..8,83..86,91..99]-[1..192]-[1..1024]
Termination Point (6500 7
PKT-OPT)
Network Media Channel NMCADCTP-shelf-slot- NMCADCTP-[0..992]-
Add/Drop Connection portSsubport-nmcId [1..8,83..86,91..99]-[1..192]S[1..192]-
Termination Point (6500 7 [1..1024]
PKT-OPT)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-
Add/Drop Connection port-nmcId [83..86,91..99]S[1..6]-[1..192]-[1..1024]
Termination Point (6500 7
PKT-OPT)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-
Add/Drop Connection portSsubport-nmcId [83..86,91..99]S[1..6]-[1..192]S[1..192]-
Termination Point (6500 7 [1..1024]
PKT-OPT)
Network Media Channel NMCADCTP-shelf-slot-port- NMCADCTP-[0..992]-[1..14,83..99]-
Add/Drop Connection nmcId [1..192]-[1..1024]
Termination Point (6500
14-Slot)
Network Media Channel NMCADCTP-shelf-slot- NMCADCTP-[0..992]-[1..14,83..99]-
Add/Drop Connection portSsubport-nmcId [1..192]S[1..192]-[1..1024]
Termination Point (6500
14-Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-[83..99]S[1..6]-
Add/Drop Connection port-nmcId [1..192]-[1..1024]
Termination Point (6500
14-Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-[83..99]S[1..6]-
Add/Drop Connection portSsubport-nmcId [1..192]S[1..192]-[1..1024]
Termination Point (6500
14-Slot)
Network Media Channel NMCADCTP-shelf-slot-port- NMCADCTP-[0..992]-
Add/Drop Connection nmcId [1..8,11..18,21..28,31..38,51..82]-
Termination Point (6500 [1..192]-[1..1024]
32-Slot)
Network Media Channel NMCADCTP-shelf-slot- NMCADCTP-[0..992]-
Add/Drop Connection portSsubport-nmcId [1..8,11..18,21..28,31..38,51..82]-
Termination Point (6500 [1..192]S[1..192]-[1..1024]
32-Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-[51..82]S[1..6]-
Add/Drop Connection port-nmcId [1..192]-[1..1024]
Termination Point (6500
32-Slot)
Network Media Channel NMCADCTP-shelf-slotSsubslot- NMCADCTP-[0..992]-[51..82]S[1..6]-
Add/Drop Connection portSsubport-nmcId [1..192]S[1..192]-[1..1024]
Termination Point (6500
32-Slot)
Network Media Channel NMCADCTP-shelf-slot-port- NMCADCTP-[0..992]-[1..12]-[1..24]-
Add/Drop Connection nmcId [1..1024]
Termination Point (6500-
T12)
Network Media Channel NMCADCTP-shelf-slot- NMCADCTP-[0..992]-[1..12]-
Add/Drop Connection portSsubport-nmcId [1..24]S[1..24]-[1..1024]
Termination Point (6500-
T12)
Input Parameter Description
Parameter Value Description Notes
active TRUE The channel will be
automatically added
when DOC Auto add
channel
FALSE The channel will be
automatically deleted
when the DOC auto
delete parameter is
enabled
auto-delete TRUE Automatic CRS
deletion enabled.
FALSE Automatic CRS
deletion disabled.
Syntax Definition
Parameter Attributes Description Notes
osid M Identifies the OTS 1-8 character string
OSID describing the Optical
System ID of the OTS.
auto-route M OTS AutoRoute
Status, doesn't apply
to Shelftype AMP and
DGE.
doc-state O Status of DOC. N/A if
this is not a DOC site
neighbor-1 O First Neighbour Identifies the
neighbor's SITE-TID-
SHELF-PATH
neighbor-2 O Second Neighbour Identifies the
neighbor's SITE-TID-
SHELF-PATH
ots M OTS ID
path M OTS Tx Path Identifier
remote-shelf M Identifies the Shelf's
Shelf ID
shelf-type M Indicates whether this
is a Channel Access,
Consolidated Channel
Access, AMP, or DGE
shelf.
site M Identifies the Shelf's
Site ID
status M Neighbor Status. Used
to indicate a problem
with one of the shelf's
neighbors.
tid M Identifies the Shelf's 1-20 character string.
TID
topo-config M Topology
Configuration.
Indicates whether the
topology for this OSID
is a Line or Ring or
Unknown
topo-flex M Topology Flexibility.
Indicates whether the
topology for this OSID
is a flexible,
nonflexible, not
applicable or unknown
Performance Monitoring
pm voa counts show Retrieve performance data and baseline for VOA entries
pm voa reset Reset performance data for VOA entries
pm voa threshold set Set Threshold for VOA entries
pm voa threshold show Retrieve Profiles for VOA entries
pm optmon counts show Retrieve performance data and baseline for OPTMON entries
pm optmon reset Reset performance data for OPTMON entries
pm optmon threshold set Set Threshold for OPTMON entries
pm optmon threshold show Retrieve Profiles for OPTMON entries
pm amp counts show Retrieve performance data and baseline for EDFA entries
pm amp reset Reset performance data for EDFA entries
pm amp threshold set Set Threshold for EDFA entries
pm amp threshold show Retrieve Profiles for EDFA entries
pm all show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm all reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm abort abort Retrieve Performance Monitoring Abort: this command allows you to abort the
active retrieve (RTRV-PM) command. If the retrieve command completes before
the abort command is processed by the system, there is no impact.
pm pmconfig set Edit PM configuration for a monitored entity
pm ettp pmconfig set Edit PM Configuration information: this command edits PM configuration data for
a monitored entity
pm osc reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm oc3 reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm wan reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm osc counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data from OSC facility.
pm oc3 counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data from OC3 facility.
pm wan counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm pmconfig show Retrieve PM configuration for a monitored entity
pm osc threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm oc3 threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm wan threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm osc threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm oc3 threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm wan threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm chmon counts show Retrieve performance data for CHMON entries.
pm chmon reset Reset performance data for CHMON entries.
pm chmon threshold set Set Threshold for CHMON entries
pm chmon threshold show Retrieve Profiles for CHMON entries
pm otdrcfg counts show Retrieve performance data and baseline for OTDRCFG entries
pm otdrcfg reset Reset performance data for OTDRCFG entries
pm otdrcfg threshold set Set Threshold for OTDRCFG entries
pm otdrcfg threshold show Retrieve Profiles for OTDRCFG entries
pm nmcmon counts show Retrieve performance data for flexible NMC channels.
pm nmcmon reset Reset performance data for flexible NMC channels.
pm nmcmon threshold set Set Threshold for NMCMON entries
pm nmcmon threshold show Retrieve Profiles for NMCMON entries
pm ptp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm ptp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm ptp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm ptp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm ptp pmconfig show Retrieve PM Configuration information: this command retrieves PM configuration
data for a monitored entity.
pm ptp pmconfig set Edit PM Configuration information: this command edits PM configuration data for
a monitored entity
pm otuttp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm otuttp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm otuttp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm otuttp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm otuttp pmconfig show Retrieve PM Configuration information: this command retrieves PM configuration
data for a monitored entity.
pm otuttp pmconfig set Edit PM Configuration information: this command edits PM configuration data for
a monitored entity
pm sttp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm sttp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm sttp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm sttp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm ettp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm ettp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm ettp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm ettp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm ettp pmconfig show Retrieve PM Configuration information: this command retrieves PM configuration
data for a monitored entity.
pm oduttp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm oduttp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm oduttp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm oduttp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm oductp counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm oductp reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm oductp threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm oductp threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
pm tcm counts show Retrieve Current/Previous Counts: this command retrieves current and historical
performance data.
pm tcm reset Initialize Register: This command allows you to initialize one or more storage
registers or event counters associated with specific entities in the NE.
pm tcm threshold set Set Threshold: Instructs the Network Element to set the threshold levels for
specified PM monitored parameters.
pm tcm threshold show Retrieve Threshold: Instructs an NE to send the current threshold level of one or
more monitored parameters for which violation will trigger an automatic message.
VOA-[0..992]-[1..12]-ALL
VOA-[0..992]-ALL
VOAALL
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
VOA-[0..992]-[1..24]-ALL
VOA-[0..992]-ALL
VOAALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type ORL-OTS Optical Return Loss
ORLMIN-OTS Optical Return Loss
Minimum
ORLMAX-OTS Optical Return Loss
Maximum
ORLAVG-OTS Optical Return Loss
Average
OPIN-OTS Optical Power Input
OPINMIN-OTS Optical Power Input
Minimum
OPINMAX-OTS Optical Power Input
Maximum
OPINAVG-OTS Optical Power Input
Average
OPOUT-OTS Optical Power Output
OPOUTMIN-OTS Optical Power Output
Minimum
OPOUTMAX-OTS Optical Power Output
Maximum
OPOUTAVG-OTS Optical Power Output
Average
GRPOPOUT-OTS Group Optical Power
Output
GRPOPOUTMIN-OTS Group Optical Power
Output Minimum
GRPOPOUTMAX-OTS Group Optical Power
Output Maximum
GRPOPOUTAVG-OTS Group Optical Power
Output Average
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file ftp://user:password@h
(inside quotes). ost[:port]/path/file. The
Example for IPv4 password cannot
address: contain the character
ftp://user:pass@xx.xx. '@'.
CLI will prompt for
xx.xx[:port]/path/filena the user password with
me or echo disabled after the
sftp://user:pass@xx.xx command is entered.
.xx.xx[:port]/path/filena
me. Example for IPv6
address:
ftp://user:pass@[abcd:
abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
voa M aid n/a
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn O Direction of signal flow
relative to network
element.
index O Proprietary method of
specifying a bin.
locn O Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type O Monitored parameter
monval O Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper O Accumulation time
period of data.
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
VOA-[0..992]-[1..12]-ALL
VOA-[0..992]-ALL
VOAALL
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
VOA-[0..992]-[1..24]-ALL
VOA-[0..992]-ALL
VOAALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
mon-type ALL
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
VOA-[0..992]-[1..12]-ALL
VOA-[0..992]-ALL
VOAALL
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
VOA-[0..992]-[1..24]-ALL
VOA-[0..992]-ALL
VOAALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type ORL-OTS Optical Return Loss
OPIN-OTS Optical Power Input
OPOUT-OTS Optical Power Output
GRPOPOUT-OTS Group Optical Power
Output
ALL
thlev string Threshold level
tmper 1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA VOA (6500-T12) VOA-shelf-slot-port VOA-[0..992]-[1..12]-[5]
VOA-[0..992]-[1..12]-ALL
VOA-[0..992]-ALL
VOAALL
RLA VOA (6500-T24) VOA-shelf-slot-port VOA-[0..992]-[1..24]-[5]
VOA-[0..992]-[1..24]-ALL
VOA-[0..992]-ALL
VOAALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
voa M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
src-profile-id O
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..12]-[41..44]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12) OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..24]-[41..44]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24) OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..12]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..24]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL objects ALL ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype OPR-OTS Optical Power Receive
OPRMIN-OTS Optical Power Receive
- Minimum
OPRMAX-OTS Optical Power Receive
- Maximum
OPRAVG-OTS Optical Power Receive
- Average
OPT-OTS Optical Power
Transmit
OPTMIN-OTS Optical Power
Transmit - Minimum
OPTMAX-OTS Optical Power
Transmit - Maximum
OPTAVG-OTS Optical Power
Transmit - Average
PSD-OTS Protection Switch
Duration
PSCW-OTS Protection Switch
Count Working
PSCP-OTS Protection Switch
Count Protection
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trex-frmt GZIP GZIP format
trex-url string Full URL to remote file ftp://user:password@h
(inside quotes). ost[:port]/path/file. The
Example for IPv4 password cannot
address: contain the character
ftp://user:pass@xx.xx. '@'.
CLI will prompt for
xx.xx[:port]/path/filena the user password with
me or echo disabled after the
sftp://user:pass@xx.xx command is entered.
.xx.xx[:port]/path/filena
me. Example for IPv6
address:
ftp://user:pass@[abcd:
abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
optmonaid M aid n/a
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn O Direction of signal flow
relative to network
element.
index O Proprietary method of
specifying a bin.
locn O Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype O Monitored parameter
monval O Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper O Accumulation time
period of data.
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..12]-[41..44]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON-[0..992]-ALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12) OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..24]-[41..44]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON-[0..992]-ALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24) OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..12]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..24]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype PSD-OTS Protection Switch
Duration
PSCW-OTS Protection Switch
Count Working
PSCP-OTS Protection Switch
Count Protection
OPR-OTS Optical Power Receive
OPRMIN-OTS Optical Power Receive
- Minimum
OPRMAX-OTS Optical Power Receive
- Maximum
OPRAVG-OTS Optical Power Receive
- Average
OPT-OTS Optical Power
Transmit
OPTMIN-OTS Optical Power
Transmit - Minimum
OPTMAX-OTS Optical Power
Transmit - Maximum
OPTAVG-OTS Optical Power
Transmit - Average
ALL
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..12]-[41..44]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12) OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..24]-[41..44]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24) OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..12]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..24]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
montype OPR-OTS Optical Power Receive
OPT-OTS Optical Power
Transmit
ALL
thlev string Threshold level
tmper 1-UNT
ALL
destprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA OPTMON (6500-T12) OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T12) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[3..4,9..13]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
portSsubport [21..26,27,29,31...37]S[2..11]
OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-
[21..26,27,29,31...37]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
RLA OPTMON (6500-T24) OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[3..4,9..13]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..12]-
OPTMON (6500-T12) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..12]-[41..44]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..12]-[1..24]
(6500-T12) OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 Subfiber OPTMON-shelf-slot- OPTMON-[0..992]-[1..24]-
OPTMON (6500-T24) portSsubport [41..44]S[3..10]
OPTMON-[0..992]-[1..24]-[41..44]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16x12 MPO OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[41..44]
OPTMON-[0..992]-ALL
OPTMONALL
CCMD16X12 OPTMON OPTMON-shelf-slot-port OPTMON-[0..992]-[1..24]-[1..24]
(6500-T24) OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 CCMD16X12 OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-[1..2]
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
AMP4 MFC OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-[1..2]
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
SUBFIBER (6500-T12) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..12]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..12]S[1..4]-
(6500-T12) port [1..8,41..42]
OPTMON-[0..992]-[1..12]S[1..4]-ALL
OPTMON-[0..992]-[1..12]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
SUBFIBER (6500-T24) portSsubport [41..42]S[3..10]
OPTMON-[0..992]-[1..24]S[1..4]-
[41..42]-ALL
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
CCMD8X4 OPTMON OPTMON-shelf-slotSsubslot- OPTMON-[0..992]-[1..24]S[1..4]-
(6500-T24) port [1..8,41..42]
OPTMON-[0..992]-[1..24]S[1..4]-ALL
OPTMON-[0..992]-[1..24]-ALL
OPTMON-[0..992]-ALL
OPTMONALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
optmonaid M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
montype O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
srcprflid O Source profile ID
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype ORL-OTS Optical Return Loss
ORLMIN-OTS Optical Return Loss
Minimum
ORLMAX-OTS Optical Return Loss
Maximum
ORLAVG-OTS Optical Return Loss
Average
OPIN-OTS Optical Power Input
OPINMIN-OTS Optical Power Input
Minimum
OPINMAX-OTS Optical Power Input
Maximum
OPINAVG-OTS Optical Power Input
Average
OPOUT-OTS Optical Power Output
OPOUTMIN-OTS Optical Power Output
Minimum
OPOUTMAX-OTS Optical Power Output
Maximum
OPOUTAVG-OTS Optical Power Output
Average
GRPGAIN-OTS Group Gain
GRPGAINMIN-OTS Group Gain Minimum
GRPGAINMAX-OTS Group Gain Maximum
GRPGAINAVG-OTS Group Gain Average
GRPOPIN-OTS Group Optical Power
Input
GRPOPINMIN-OTS Group Optical Power
Input Minimum
GRPOPINMAX-OTS Group Optical Power
Input Maximum
GRPOPINAVG-OTS Group Optical Power
Input Average
GRPOPOUT-OTS Group Optical Power
Output
GRPOPOUTMIN-OTS Group Optical Power
Output Minimum
GRPOPOUTMAX-OTS Group Optical Power
Output Maximum
GRPOPOUTAVG-OTS Group Optical Power
Output Average
DROPGAIN-OTS Drop Gain
DROPGAINMIN-OTS Drop Gain Minimum
DROPGAINMAX-OTS Drop Gain Maximum
DROPGAINAVG-OTS Drop Gain Average
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trex-frmt GZIP GZIP format
trex-url string Full URL to remote file ftp://user:password@h
(inside quotes). ost[:port]/path/file. The
Example for IPv4 password cannot
address: contain the character
ftp://user:pass@xx.xx. '@'.
CLI will prompt for
xx.xx[:port]/path/filena the user password with
me or echo disabled after the
sftp://user:pass@xx.xx command is entered.
.xx.xx[:port]/path/filena
me. Example for IPv6
address:
ftp://user:pass@[abcd:
abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
ampaid M aid n/a
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn O Direction of signal flow
relative to network
element.
index O Proprietary method of
specifying a bin.
locn O Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype O Monitored parameter
monval O Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper O Accumulation time
period of data.
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype ALL
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
montype ORL-OTS Optical Return Loss
OPIN-OTS Optical Power Input
OPOUT-OTS Optical Power Output
GRPGAIN-OTS Group Gain
GRPOPIN-OTS Group optical Power
Input
GRPOPOUT-OTS Group optical Power
Output
DROPGAIN-OTS Drop gain
ALL
thlev string Threshold level
tmper 1-UNT
ALL
destprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA AMP (6500-T12) AMP-shelf-slot-port AMP-[0..992]-[1..12]-[5..8,100]
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
RLA AMP (6500-T24) AMP-shelf-slot-port AMP-[0..992]-[1..24]-[5..8,100]
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
CCMD16X12 (6500-T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..12]S[1..4]-
T12) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..12]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..12]S[1..4]-ALL
AMP-[0..992]-[1..12]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
CCMD16X12 (6500-T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
AMP4 AMP on MFC (6500- AMP-shelf-slotSsubslot- AMP-[0..992]-[1..24]S[1..4]-
T24) portSsubport [1..2]S[3..10]
AMP-[0..992]-[1..24]S[1..4]-[1..2]-ALL
AMP-[0..992]-[1..24]S[1..4]-ALL
AMP-[0..992]-[1..24]-ALL
AMP-[0..992]-ALL
AMPALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
ampaid M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
montype O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
srcprflid O Source profile ID
AID Descriptions
AID Type Format Values
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
CV-P Coding Violations -
Path
ES-P Errored Seconds -
Path
SES-P Severely Errored
Seconds - Path
UAS-P Unavailable Seconds -
Path
FC-P Failure Count - Path
CV-V Coding Violations - VT
ES-V Errored Seconds - VT
SES-V Severely Errored
Seconds - VT
UAS-V Unavailable Seconds -
VT
FC-V Failure Count - VT
SAS-P SEF/AIS Seconds -
Path
SEFS-P Severely Errored
Frame Seconds - Path
CSS-P Controlled Slip
Seconds - Path
CVC-P Coding Violation, C-bit,
Path
ESC-P Errored Second, C-bit,
Path
SESC-P Severely Errored
Second, C-bit, Path
UASC-P Unavailable Second,
C-bit, Path
FCC-P Failure Count, C-bit,
Path
ES-CES Error Second - Circuit
Emulation Service
SES-CES Severely Errored
Second - Circuit
Emulation Service
UAS-CES Unavailable Second -
Circuit Emulation
Service
PSCW-L Protection switch
count, working line -
LINE
PSCP-L Protection switch
count, protection line -
LINE
PSD-L Protection switch
duration, line - LINE
OPR-OCH Optical Power Receive
- Optical Channel.
When tmper=1-UNT
this is a gauge value;
when tmper=1-15-MIN,
1-DAY this is a
snapshot value
OPT-OCH Gauge Optical Power
Transmit - Optical
Channel
OPTMIN-OCH Minimum OPT for
interval
OPTMAX-OCH Maximum OPT for
interval
OPTAVG-OCH Average OPT for
interval
OPRN-OCH Optical Power Receive
- Normalized - Optical
Channel
OPRMIN-OCH Optical Power Receive
Min - Optical Channel
OPRMAX-OCH Optical Power Receive
Max - Optical Channel
OPRAVG-OCH Optical Power Receive
Avg - Optical Channel
OPTN-OCH Optical Power
Transmit - Normalized
- Optical Channel
OPRLOW-OCH Lowest optical power
received.
OPRNLOW-OCH Lowest optical power
received (normalized).
OPRHIGH-OCH Highest optical power
received
OPRNHIGH-OCH Highest optical power
received (normalized).
OPTLOW-OCH Lowest optical power
transmitted
OPTNLOW-OCH Lowest optical power
transmitted
(normalized)
OPTHIGH-OCH Highest optical power
transmitted
OPTNHIGH-OCH Highest optical power
transmitted
(normalized)
SPANLOSS-OCH The OSC Span Loss in
dB
SPANLOSSMIN-OCH Minimum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSMAX-OCH Maximum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSAVG-OCH Average OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
PDLAVG-OCH Polarization
Dependent Loss,
Average - OCH
PDLMAX-OCH Polarization
Dependent Loss,
Maximum - OCH
CDMIN-OCH Dispersion
compensation
(Minimum) OCH
CDMAX-OCH Dispersion
compensation
(Maximum) OCH
CDAVG-OCH Dispersion
compensation
(Average) OCH
OPR-OTS Optical Power
Received - Optical
Transport Section
OPRN-OTS Optical Power Receive
- Normalized - Optical
Transport Section
CV-OTU Coding Violations -
OTU
ES-OTU Errored Seconds -
OTU
SES-OTU Severely Errored
Seconds - OTU
SEFS-OTU Severely Errored
Framing Seconds -
OTU
FEC-OTU Forward Error
Corrections - OTU
HCCS-OTU High Correction Count
Seconds - OTU
PFBERE-OTU Post-FEC Bit Error
Rate Estimates - OTU.
When tmper=1-UNT
this is a gauge value;
when tmper=1-15-MIN,
1-DAY this is a
snapshot value
PRFBER-OTU Pre-FEC Bit Error Rate
- OTU.
PRFBERMAX-OTU Pre-FEC Bit Max Error
Rate - OTU
QMIN-OTU Minimum Q - OTU
QMAX-OTU Maximum Q - OTU
QAVG-OTU Average Q - OTU
QSTDEV-OTU Q Standard Deviation -
OTU
UNCFECBLK-OTU Uncorrected FEC
Block - OTU
IAE-OTU Incoming Alignment
Error - OTU
CV-ODU Coding Violations -
ODU
ES-ODU Errored Seconds -
ODU
SES-ODU Severely Errored
Seconds - ODU
UAS-ODU Unavailable Seconds -
ODU
FC-ODU Failure Count - ODU
DMMIN-ODU Delay Measurement
Min - ODU
DMMAX-ODU Delay Measurement
Max - ODU
DMAVG-ODU Delay Measurement
Avg - ODU
PSD-ODU Protection Switch
Duration
PSCP-ODU Protection Switch
Count - Protection
PSCW-ODU Protection Switch
Count - Working
CV-TCM Coding Violations -
TCM
ES-TCM Errored Seconds -
TCM
SES-TCM Severely Errored
Seconds - TCM
UAS-TCM Unavailable Seconds -
TCM
FC-TCM Failure Count - TCM
PSD-TCM Protection Switch
Duration - TCM
PSCW-TCM Protection Switch
Count, Working - TCM
PSCP-TCM Protection Switch
Count, Protection -
TCM
DMMIN-TCM Delay Measurement
Min - TCM
DMMAX-TCM Delay Measurement
Max - TCM
DMAVG-TCM Delay Measurement
Avg - TCM
IAE-TCM Incoming Alignment
Error - TCM
CV-PCS Coding Violations -
Physical Coding
Sublayer
ES-PCS Errored Seconds -
Physical Coding
Sublayer
SES-PCS Severely Errored
Seconds - Physical
Coding Sublayer
UAS-PCS Unavailable Seconds -
Physical Coding
Sublayer
ES-E Errored Seconds -ETH
SES-E Severely Errored
Seconds
UAS-E Unavailable Seconds
INFRAMES-E Number of frames
received (binned OM) -
Ethernet.
OUTFRAMES-E Frame Check
Sequence Errors
(binned OM) - Ethernet
INFRAMESERR-E Number of errored
frames received
OUTFRAMESERR-E Number of errored
frames transmitted
INFRAMESDISCDS-E Number of ingress
discarded frames due
to congestion or
overflow
OUTFRAMESDISCDS-E Number of egress
discarded frames due
to congestion or
overflow
DFR-E Aggregate count of
discarded frames
FCSERR-E Frame Check
Sequence Errors
FEC-PMA Forward Error
Corrections - Physical
Medium Attachment
FECCCW-PMA Forward Error
Corrections Corrected
Codewords - Physical
Medium Attachment
FECUNCCW-PMA Forward Error
Corrections
Uncorrected
Codewords - Physical
Medium Attachment
HCCS-PMA High Correction Count
Second - Physical
Medium Attachment
PRFBER-PMA Pre-FEC Bit Error Rate
(Average) - Physical
Medium Attachment
PRFBERMAX-PMA Pre-FEC Bit Error Rate
Maximum - Physical
Medium Attachment
REMOTEINFRAMES-E Remote In Frames
REMOTEOUTFRAMES-E Remote Out Frames
REMOTEINFRAMESERR-E Remote In Frames Err
REMOTEOUTFRAMESDISCDS-E Remote Out Frames
Disc
REMOTEFCSERR-E Remote FCS Err
GRPOPT-OTS Group Optical Power
Transmit
GRPOPTMIN-OTS Group Optical Power
Transmit - Minimum
GRPOPTMAX-OTS Group Optical Power
Transmit - Maximum
GRPOPTAVG-OTS Group Optical Power
Transmit - Average
OPROSC-OTS Optical Power
Receive, OSC
OPROSCMIN-OTS Optical Power
Receive, OSC
Minimum
OPROSCMAX-OTS Optical Power
Receive, OSC
Maximum
OPROSCAVG-OTS Optical Power
Receive, OSC
Average
ORLIN-OTS Optical Return Loss
Input
ORLINMIN-OTS Optical Return Loss
Input Minimum
ORLINMAX-OTS Optical Return Loss
Input Maximum
ORLINAVG-OTS Optical Return Loss
Input Average
ORLOUT-OTS Optical Return Loss
Output
ORLOUTMIN-OTS Optical Return Loss
Output Minimum
ORLOUTMAX-OTS Optical Return Loss
Output Maximum
ORLOUTAVG-OTS Optical Return Loss
Output Average
OPR-OTS Optical Power Receive
OPRMIN-OTS Optical Power Receive
- Minimum
OPRMAX-OTS Optical Power Receive
- Maximum
OPRAVG-OTS Optical Power Receive
- Average
OPT-OTS Optical Power
Transmit
OPTMIN-OTS Optical Power
Transmit - Minimum
OPTMAX-OTS Optical Power
Transmit - Maximum
OPTAVG-OTS Optical Power
Transmit - Average
ORL-OTS Optical Return Loss
ORLMIN-OTS Optical Return Loss
Minimum
ORLMAX-OTS Optical Return Loss
Maximum
ORLAVG-OTS Optical Return Loss
Average
OPIN-OTS Optical Power Input
OPINMIN-OTS Optical Power Input
Minimum
OPINMAX-OTS Optical Power Input
Maximum
OPINAVG-OTS Optical Power Input
Average
OPOUT-OTS Optical Power Output
OPOUTMIN-OTS Optical Power Output
Minimum
OPOUTMAX-OTS Optical Power Output
Maximum
OPOUTAVG-OTS Optical Power Output
Average
GRPGAIN-OTS Group Gain
GRPGAINMIN-OTS Group Gain Minimum
GRPGAINMAX-OTS Group Gain Maximum
GRPGAINAVG-OTS Group Gain Average
GRPOPIN-OTS Group Optical Power
Input
GRPOPINMIN-OTS Group Optical Power
Input Minimum
GRPOPINMAX-OTS Group Optical Power
Input Maximum
GRPOPINAVG-OTS Group Optical Power
Input Average
GRPOPOUT-OTS Group Optical Power
Output
GRPOPOUTMIN-OTS Group Optical Power
Output Minimum
GRPOPOUTMAX-OTS Group Optical Power
Output Maximum
GRPOPOUTAVG-OTS Group Optical Power
Output Average
DROPGAIN-OTS Drop Gain
DROPGAINMIN-OTS Drop Gain Minimum
DROPGAINMAX-OTS Drop Gain Maximum
DROPGAINAVG-OTS Drop Gain Average
PSD-OTS Protection Switch
Duration
PSCW-OTS Protection Switch
Count Working
PSCP-OTS Protection Switch
Count Protection
EVCSH-OTS Event Count Short
EVCSHMAX-OTS Event Count Short -
MAX
EVCLG-OTS Event Count Long
EVCLGMAX-OTS Event Count Long -
MAX
MAXEVLDISSH-OTS Maximum Event Loss
Distance Short
MAXEVLDISSHMAX-OTS Maximum Event Loss
Distance Short - MAX
MAXEVLDISLG-OTS Maximum Event Loss
Distance Long
MAXEVLDISLGMAX-OTS Maximum Event Loss
Distance Long - MAX
MAXEVRDISSH-OTS Maximum Event
Reflection Distance
Short
MAXEVRDISSHMAX-OTS Maximum Event
Reflection Distance
Short - MAX
MAXEVRDISLG-OTS Maximum Event
Reflection Distance
Long
MAXEVRDISLGMAX-OTS Maximum Event
Reflection Distance
Long - MAX
MAXEVLSH-OTS Maximum Event Loss
Short
MAXEVLSHMAX-OTS Maximum Event Loss
Short - MAX
MAXEVLLG-OTS Maximum Event Loss
Long
MAXEVLLGMAX-OTS Maximum Event Loss
Long - MAX
MAXEVRSH-OTS Maximum Event
Reflection Short
MAXEVRSHMAX-OTS Maximum Event
Reflection Short - MAX
MAXEVRLG-OTS Maximum Event
Reflection Long
MAXEVRLGMAX-OTS Maximum Event
Reflection Long - MAX
CUMEVLSH-OTS Cumulative Event Loss
Short
CUMEVLSHMAX-OTS Cumulative Event Loss
Short MAX
CUMEVLLG-OTS Cumulative Event Loss
Long
CUMEVLLGMAX-OTS Cumulative Event Loss
Long MAX
CUMEVRSH-OTS Cumulative Event
Reflection Short
CUMEVRSHMAX-OTS Cumulative Event
Reflection Short MAX
CUMEVRLG-OTS Cumulative Event
Reflection Long
CUMEVRLGMAX-OTS Cumulative Event
Reflection Long MAX
DMMIN-L Delay Measurement
MINimum - Line
DMMAX-L Delay Measurement
MAXimum - Line
DMAVG-L Delay Measurement
AVGrage - Line
ES-W Errored Seconds -
WAN
SES-W Severely Errored
Seconds - WAN
UAS-W Unavailable Seconds -
WAN
INFRAMES-W Number of frames
received (binned OM) -
WAN
INFRAMESERR-W Number of errored
frames received -
WAN
OUTFRAMES-W Number of frames
transmitted (binned
OM)- WAN
DGDAVG-OCH Differential Group
Delay (Average),
Optical Channel
DGDMAX-OCH Differential Group
Delay (Max), Optical
Channel
LDS-W LCAS Degraded Applicable to L2SS,
Second - WAN (Rx 24xFE, PDH.
and Tx directions)
LSDS-W LCAS Severely Applicable to L2SS,
Degraded Second - 24xFE, PDH.
WAN (Rx and Tx
directions)
LUAS-W LCAS Unavailable Applicable to L2SS,
Second - WAN (Rx 24xFE, PDH.
and Tx directions)
DFR-W Aggregate count of
discarded frames -
WAN
UTL-W Average percentage
link utilization - WAN
UTLMX-W Maximum percentage
link utilization - WAN
OUTFRAMESERR-W Out Frames Error
Count, Wan
OPR-OTSI Optical Power
Receive- OTSI
OPT-OTSI Optical Power
Transmit- OTSI
OPRN-OTSI Normalized Optical
Power Receive- OTSI
OPTN-OTSI Normalized Optical
Power Transmit- OTSI
OPRAVG-OTSI Optical Power
Receive, Average -
OTSI
OPRMIN-OTSI Optical Power
Receive, Minimum -
OTSI
OPRMAX-OTSI Optical Power
Receive, Maximum -
OTSI
OPTAVG-OTSI Optical Power
Transmit, Average -
OTSI
OPTMIN-OTSI Optical Power
Transmit, Minimum -
OTSI
OPTMAX-OTSI Optical Power
Transmit, Maximum -
OTSI
DGDAVG-OTSI Differential Group
Delay (Average) OTSI
DGDMAX-OTSI Differential Group
Delay (Maximum)
OTSI
PDLAVG-OTSI Polarization
Dependent Loss,
Average - OTSI
PDLMAX-OTSI Polarization
Dependent Loss,
Maximum - OTSI
HCCS-OTSI High Correction Count
Seconds - OTSI
FEC-OTSI FEC Corrections -
OTSI
PRFBER-OTSI Post-FEC BER - OTSI
PRFBERMAX-OTSI Pre-FEC BER
Maximum - OTSI
QMIN-OTSI Q MIN - OTSI
QMAX-OTSI Q MAX - OTSI
QAVG-OTSI Q AVG - OTSI
QSTDEV-OTSI Q StDev - OTSI
UNCFECBLK-OTSI Uncorrected FEC
Block - OTSI
OSNRMIN-OTSI Optical Signal to Noise
Ratio (Minimum) OTSI
OSNRMAX-OTSI Optical Signal to Noise
Ratio (Maximum) OTSI
OSNRAVG-OTSI Optical Signal to Noise
Ratio (Average) OTSI
ESNRMIN-OTSI Electrical Signal to
Noise Ratio (Minimum)
OTSI
ESNRMAX-OTSI Electrical Signal to
Noise Ratio
(Maximum) OTSI
ESNRAVG-OTSI Electrical Signal to
Noise Ratio (Average)
OTSI
CDMIN-OTSI Dispersion
compensation
(Minimum) OTSI
CDMAX-OTSI Dispersion
compensation
(Maximum) OTSI
CDAVG-OTSI Dispersion
compensation
(Average) OTSI
CSIMIN-OTSI Cyclic Slip Indicator
(Minimum) - OTSi
CSIMAX-OTSI Cyclic Slip Indicator
(Maximum) - OTSi
CSIAVG-OTSI Cyclic Slip Indicator
(Average) - OTSi
SNREXTMIN-OTSI Signal to Noise Ratio
External (Minimum) -
OTSi
SNREXTMAX-OTSI Signal to Noise Ratio
External (Maximum) -
OTSi
SNREXTAVG-OTSI Signal to Noise Ratio
External (Average) -
OTSi
FEC-PCS Forward Error
Corrections - Physical
Coding Sublayer
FECCCW-PCS Forward Error
Corrections Corrected
Codewords - Physical
Coding Sublayer
FECUNCCW-PCS Forward Error
Corrections
Uncorrected
Codewords - Physical
Coding Sublayer
HCCS-PCS High Correction Count
Second - Physical
Coding Sublayer
PRFBER-PCS Pre-FEC Bit Error Rate
(Average) - Physical
Coding Sublayer
PRFBERMAX-PCS Pre-FEC Bit Error Rate
Maximum - Physical
Coding Sublayer
UTLMIN-E Percent Bandwidth
Utilization Min
UTLMAX-E Percent Bandwidth
Utilization Max
UTLAVG-E Percent Bandwidth
Utilization Avg
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file (a)The password
(inside quotes). cannot contain the
Example for IPv4 character '@'.
address: (b)Sample FTP URL
ftp://user:pass@xx.xx. with IPv4 address
xx.xx[:port]/path/filena ftp://userid:password@
me or xx.xx.xx.xx:port/path/fil
sftp://user:pass@xx.xx e (c)IPv6 address will
.xx.xx[:port]/path/filena be enclosed in [] for
me. Example for IPv6 e.g
address: ftp://userid:password@
ftp://user:pass@[abcd: [abcd:abcd:abcd:abcd:
abcd:abcd:abcd:abcd: abcd:abcd:abcd:abcd]:
abcd:abcd:abcd] port/path/file CLI will
[:port]/path/filename or prompt for the user
sftp://user:pass@[abcd password with echo
:abcd:abcd:abcd:abcd: disabled after the
abcd:abcd:abcd] command is entered.
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
shelf M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type ALL All applicable
montypes
monval INT The value of the
(0) monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
src-profile-id DFLT Source profile ID
AID Descriptions
AID Type Format Values
SHELF SHELF-shelf SHELF-[0..992]
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
src-profile-id DFLT Default Source Profile
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
shelf M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-profile-id M Source profile ID
AID Descriptions
AID Type Format Values
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
Input Parameter Description
Parameter Value Description Notes
hccs-ref string Floating point value
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
hccs-ref string Margin in dBQ relative
to a post FEC BER of
1E-12. (floating point
value)
AID Descriptions
AID Type Format Values
RLA OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC-[0..992]-[1..12]-ALL
OSC-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
OPR-OCH Optical Power Receive When tmper=1-UNT
this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPT-OCH Optical Power When tmper=1-UNT
Transmit this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPRMIN-OCH Optical Power Receive
Min - Optical Channel
OPRMAX-OCH Optical Power Receive
Max - Optical Channel
OPRAVG-OCH Optical Power Receive
Avg - Optical Channel
OPTAVG-OCH Optical Power
Transmit Avg - Optical
Channel
OPTMIN-OCH Optical Power
Transmit Min - Optical
Channel
OPTMAX-OCH Optical Power
Transmit Max - Optical
Channel
SPANLOSS-OCH The OSC Span Loss in
dB
SPANLOSSMIN-OCH Minimum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSMAX-OCH Maximum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSAVG-OCH Average OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
DMMIN-L Delay Measurement
MINimum - Line
DMMAX-L Delay Measurement
MAXimum - Line
DMAVG-L Delay Measurement
AVGrage - Line
ALL All applicable valid only as an input
montypes parameter
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
OC3 Facility (6500 7-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 7 PKT- OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 14-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..8]
OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 32-Slot) OC3-shelf-slot-port OC3-[0..992]-
[1..8,11..18,21..28,31..38]-[1..8]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 7 OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..16]
PKT-OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..16]
14-Slot) OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-
32-Slot) [1..8,11..18,21..28,31..38]-[1..16]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
OPR-OCH Optical Power Receive When tmper=1-UNT
this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPRMIN-OCH Optical Power Receive
Min - Optical Channel
OPRMAX-OCH Optical Power Receive
Max - Optical Channel
OPRAVG-OCH Optical Power Receive
Avg - Optical Channel
OPT-OCH Optical Power When tmper=1-UNT
Transmit this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPTAVG-OCH Optical Power
Transmit Avg - Optical
Channel
OPTMIN-OCH Optical Power
Transmit Min - Optical
Channel
OPTMAX-OCH Optical Power
Transmit Max - Optical
Channel
OPRN-OCH Optical Power Receive When tmper=1-UNT
- Normalized this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPTN-OCH Optical Power When tmper=1-UNT
Transmit - Normalized this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
PSCW-L Protection Switch
Count Working - Line
PSCP-L Protection Switch
Count Protection - Line
PSD-L Protection Switch
Duration - Line
ALL All applicable valid only as an input
montypes parameter
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2,101..228]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
monval INT The value of the
(0) monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
OSC-[0..992]-[1..12]-ALL
OSC-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
OPR-OCH Optical Power Receive When tmper=1-UNT
this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPT-OCH Optical Power When tmper=1-UNT
Transmit this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPRMIN-OCH Optical Power Receive
Min - Optical Channel
OPRMAX-OCH Optical Power Receive
Max - Optical Channel
OPRAVG-OCH Optical Power Receive
Avg - Optical Channel
OPTAVG-OCH Optical Power
Transmit Avg - Optical
Channel
OPTMIN-OCH Optical Power
Transmit Min - Optical
Channel
OPTMAX-OCH Optical Power
Transmit Max - Optical
Channel
SPANLOSS-OCH The OSC Span Loss in
dB
SPANLOSSMIN-OCH Minimum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSMAX-OCH Maximum OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
SPANLOSSAVG-OCH Average OSC Span
Loss, When tmper=1-
UNT this is a gauge
value; when tmper=1-
15-MIN, 1-DAY this is
a snapshot value
DMMIN-L Delay Measurement
MINimum - Line
DMMAX-L Delay Measurement
MAXimum - Line
DMAVG-L Delay Measurement
AVGrage - Line
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
osc M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
portmode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 7 PKT- OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 14-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..8]
OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 32-Slot) OC3-shelf-slot-port OC3-[0..992]-
[1..8,11..18,21..28,31..38]-[1..8]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 7 OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..16]
PKT-OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..16]
14-Slot) OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-
32-Slot) [1..8,11..18,21..28,31..38]-[1..16]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
OPR-OCH Optical Power Receive When tmper=1-UNT
this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPRMIN-OCH Optical Power Receive
Min - Optical Channel
OPRMAX-OCH Optical Power Receive
Max - Optical Channel
OPRAVG-OCH Optical Power Receive
Avg - Optical Channel
OPT-OCH Optical Power When tmper=1-UNT
Transmit this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPTAVG-OCH Optical Power
Transmit Avg - Optical
Channel
OPTMIN-OCH Optical Power
Transmit Min - Optical
Channel
OPTMAX-OCH Optical Power
Transmit Max - Optical
Channel
OPRN-OCH Optical Power Receive When tmper=1-UNT
- Normalized this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
OPTN-OCH Optical Power When tmper=1-UNT
Transmit - Normalized this is a gauge value;
when tmper=1-15-
MIN, 1-DAY this is a
snapshot value
PSCW-L Protection Switch
Count Working - Line
PSCP-L Protection Switch
Count Protection - Line
PSD-L Protection Switch
Duration - Line
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
oc3 M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..4]
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2,101..228]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype ES-W WAN Errored seconds
(RX)
SES-W WAN Severely Errored
Seconds (Rx)
UAS-W WAN Unavailable
Seconds (Rx)
INFRAMES-W Total WAN frames
received
INFRAMESERR-W Total WAN frames
received with errors
OUTFRAMES-W Total WAN frames
transmitted
OUTFRAMESERR-W Out Frames Error
Count, WAN
DFR-W Total frames discarded Eg: undersized
for any reason other frames, and frames
than FCS errors (Rx containing unknown
and Tx) VCE ID.
UTL-W Average WAN link Not applicable to L2SS
Utilization (Rx and Tx)
UTLMX-W Maximum (peak) WAN Not applicable to L2SS
link Utilization (Rx and
Tx)
LDS-W LCAS Degraded Applicable to L2SS,
Second - WAN (Rx 24xFE, PDH.
and Tx directions)
LSDS-W LCAS Severely Applicable to L2SS,
Degraded Second - 24xFE, PDH.
WAN (Rx and Tx
directions)
LUAS-W LCAS Unavailable Applicable to L2SS,
Second - WAN (Rx 24xFE, PDH.
and Tx directions)
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
wan M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
montype M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
RLA OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC-[0..992]-[1..12]-ALL
OSC-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prfl-info N do not list profile
information
Y list profile information
src-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
osc M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
montype O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-prfl-id M Source profile ID
AID Descriptions
AID Type Format Values
OC3 Facility (6500 7-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 7 PKT- OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 14-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..8]
OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 32-Slot) OC3-shelf-slot-port OC3-[0..992]-
[1..8,11..18,21..28,31..38]-[1..8]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 7 OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..16]
PKT-OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..16]
14-Slot) OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-
32-Slot) [1..8,11..18,21..28,31..38]-[1..16]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
oc3 M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
montype O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
srcprflid M Source profile ID
AID Descriptions
AID Type Format Values
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..4]
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2,101..228]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
wan M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
srcprflid M Source profile ID
Output Parameter Description
Parameter Value Description Notes
aidtype WAN AID type
wan ident aid
dirn RCV Receive direction only
TRMT Transmit direction only
locn NEND Near End
FEND Far End
thlev string The provisioned
threshold level for
montype
tmper 15-MIN
1-DAY
1-UNT
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
AID Descriptions
AID Type Format Values
RLA OSC (6500-T12) OSC-shelf-slot-port OSC-[0..992]-[1..12]-[2]
OSC-[0..992]-[1..12]-ALL
OSC-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
OPR-OCH Optical Power Receive
- Optical Channel.
When tmper=1-UNT
this is a gauge value;
when tmper=1-15-MIN,
1-DAY this is a
snapshot value
OPT-OCH Optical Power
Transmit - Optical
Channel
SPANLOSS-OCH The OSC Span Loss in
dB
DMMIN-L Delay Measurement
MINimum - Line
DMMAX-L Delay Measurement
MAXimum - Line
DMAVG-L Delay Measurement
AVGrage - Line
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
dest-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
OC3 Facility (6500 7-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 7 PKT- OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..8]
OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 14-Slot) OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..8]
OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
OC3 Facility (6500 32-Slot) OC3-shelf-slot-port OC3-[0..992]-
[1..8,11..18,21..28,31..38]-[1..8]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 7 OC3-shelf-slot-port OC3-[0..992]-[1..6]-[1..16]
PKT-OPT) OC3-[0..992]-[1..6]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-[1..6,9..14]-[1..16]
14-Slot) OC3-[0..992]-[1..6,9..14]-ALL
OC3-[0..992]-ALL
MRO OC3 Facility (6500 OC3-shelf-slot-port OC3-[0..992]-
32-Slot) [1..8,11..18,21..28,31..38]-[1..16]
OC3-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OC3-[0..992]-ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
montype CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
OPR-OCH Optical Power Receive
- Optical Channel.
When tmper=1-UNT
this is a gauge value;
when tmper=1-15-MIN,
1-DAY this is a
snapshot value
OPT-OCH Optical Power
Transmit - Optical
Channel
OPRN-OCH Optical Power Receive
- Normalized - Optical
Channel
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
destprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..4]
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..4]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on GE card WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..4]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-[1..24]
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..8]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on FE card WAN-shelf-slot-port WAN-[0..992]-[1..4]-[1..8]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2,101..228]
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-[1..6,9..14]-
(6500 14-Slot) [1..2,101..228]
WAN-[0..992]-[1..6,9..14]-ALL
WAN-[0..992]-ALL
WAN port on L2 cards WAN-shelf-slot-port WAN-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-
[1..2,101..228]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..2]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..7]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..6]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-[1..14]-[1..2]
WAN-[0..992]-ALL
WAN port on L2MOTR WAN-shelf-slot-port WAN-[0..992]-
card (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..2]
WAN-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..12]-[1..40]S[1..4]
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slot-portSsubport WAN-[0..992]-[1..24]-[1..40]S[1..4]
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T12) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..12]S[1..3]-[1..12]
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
WAN (6500-T24) WAN-shelf-slotSsubslot-port WAN-[0..992]-[1..24]S[1..3]-[1..12]
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..12]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port WAN-[0..992]-[1..12]-[1..40]
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..12]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..12]-[1..2]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1 WAN-[0..992]-[1..24]-[1..40]-
[2,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]-[2,4,CN]-
ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..2]-
[2,2E,3,4,CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port WAN-[0..992]-[1..24]-[1..40]
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-port-rt1Ptp1- WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]P[1]-
ALL
WAN-[0..992]-[1..24]-[1..2]-[CN]-ALL
WAN-[0..992]-[1..24]-[1..2]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..12]-[1..40]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slot-portSsubport- WAN-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]-[1..40]S[1..4]-ALL
WAN-[0..992]-[1..24]-[1..40]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T12) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..32]
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..12]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..12]S[1..3]-ALL
WAN-[0..992]-[1..12]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot- WAN-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..8]
WAN-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..12]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..32]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
Mapped WAN (6500-T24) WAN-shelf-slotSsubslot-port- WAN-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-
[CN]P[1]-ALL
WAN-[0..992]-[1..24]S[1..3]-[1..5]-ALL
WAN-[0..992]-[1..24]S[1..3]-ALL
WAN-[0..992]-[1..24]-ALL
WAN-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
destprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
srcprflid PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA CHMON (6500-T12) CHMON-shelf-slot-port- CHMON-[0..992]-[1..12]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON (6500-T24) CHMON-shelf-slot-port- CHMON-[0..992]-[1..24]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..12]-[5,8]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..24]-[5,8]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL SLOTS CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
All CHMON ports on shelf CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
ALL objects ALL ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type OPT-OCH Optical Channel Power
Transmit.
OPTMIN-OCH Optical Channel Power
Transmit Minimum.
OPTMAX-OCH Optical Channel Power
Transmit Maximum.
OPTAVG-OCH Optical Channel Power
Transmit Average.
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
chmon M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level(HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
RLA CHMON (6500-T12) CHMON-shelf-slot-port- CHMON-[0..992]-[1..12]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
RLA CHMON (6500-T24) CHMON-shelf-slot-port- CHMON-[0..992]-[1..24]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..12]-[5,8]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..24]-[5,8]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL SLOTS CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
All CHMON ports on shelf CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type ALL
monval string The value of the
monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
RLA CHMON (6500-T12) CHMON-shelf-slot-port- CHMON-[0..992]-[1..12]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON (6500-T24) CHMON-shelf-slot-port- CHMON-[0..992]-[1..24]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..12]-[5,8]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..24]-[5,8]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL SLOTS CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
All CHMON ports on shelf CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type OPT-OCH Optical Channel Power
Transmit.
ALL
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA CHMON (6500-T12) CHMON-shelf-slot-port- CHMON-[0..992]-[1..12]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON (6500-T24) CHMON-shelf-slot-port- CHMON-[0..992]-[1..24]-[5,8]-
wavelength [0..999999]
CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..12]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL PORTS CHMON-shelf-slot-ALL CHMON-[0..992]-[1..24]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..12]-[5,8]-ALL
(6500-T12) CHMON-[0..992]-[1..12]-[5,8]-ALL
CHMON-[0..992]-[1..12]-ALL
CHMON-[0..992]-ALL
CHMONALL
RLA CHMON ALL WL CHMON-shelf-slot-port-ALL CHMON-[0..992]-[1..24]-[5,8]-ALL
(6500-T24) CHMON-[0..992]-[1..24]-[5,8]-ALL
CHMON-[0..992]-[1..24]-ALL
CHMON-[0..992]-ALL
CHMONALL
CHMON ALL SLOTS CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
All CHMON ports on shelf CHMON-shelf-ALL CHMON-[0..992]-ALL
CHMON-[0..992]-ALL
CHMONALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
chmon M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
src-profile-id O
T12) OTDRCFGALL
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..24]-ALL
T24) OTDRCFGALL
OTDRCFG All Slots OTDRCFG-shelf-ALL OTDRCFG-[0..992]-ALL
OTDRCFGALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype EVCSH-OTS Event Count Short
EVCSHMAX-OTS Event Count Short -
MAX
EVCLG-OTS Event Count Long
EVCLGMAX-OTS Event Count Long -
MAX
MAXEVLDISSH-OTS Maximum Event Loss
Distance Short
MAXEVLDISSHMAX-OTS Maximum Event Loss
Distance Short - MAX
MAXEVLDISLG-OTS Maximum Event Loss
Distance Long
MAXEVLDISLGMAX-OTS Maximum Event Loss
Distance Long - MAX
MAXEVRDISSH-OTS Maximum Event
Reflection Distance
Short
MAXEVRDISSHMAX-OTS Maximum Event
Reflection Distance
Short - MAX
MAXEVRDISLG-OTS Maximum Event
Reflection Distance
Long
MAXEVRDISLGMAX-OTS Maximum Event
Reflection Distance
Long - MAX
MAXEVLSH-OTS Maximum Event Loss
Short
MAXEVLSHMAX-OTS Maximum Event Loss
Short - MAX
MAXEVLLG-OTS Maximum Event Loss
Long
MAXEVLLGMAX-OTS Maximum Event Loss
Long - MAX
MAXEVRSH-OTS Maximum Event
Reflection Short
MAXEVRSHMAX-OTS Maximum Event
Reflection Short - MAX
MAXEVRLG-OTS Maximum Event
Reflection Long
MAXEVRLGMAX-OTS Maximum Event
Reflection Long - MAX
CUMEVLSH-OTS Cumulative Event Loss
Short
CUMEVLSHMAX-OTS Cumulative Event Loss
Short MAX
CUMEVLLG-OTS Cumulative Event Loss
Long
CUMEVLLGMAX-OTS Cumulative Event Loss
Long MAX
CUMEVRSH-OTS Cumulative Event
Reflection Short
CUMEVRSHMAX-OTS Cumulative Event
Reflection Short MAX
CUMEVRLG-OTS Cumulative Event
Reflection Long
CUMEVRLGMAX-OTS Cumulative Event
Reflection Long MAX
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trex-frmt GZIP GZIP format
trex-url string Full URL to remote file ftp://user:password@h
(inside quotes). ost[:port]/path/file. The
Example for IPv4 password cannot
address: contain the character
ftp://user:pass@xx.xx. '@'.
CLI will prompt for
xx.xx[:port]/path/filena the user password with
me or echo disabled after the
sftp://user:pass@xx.xx command is entered.
.xx.xx[:port]/path/filena
me. Example for IPv6
address:
ftp://user:pass@[abcd:
abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
otdrcfg M aid n/a
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn O Direction of signal flow
relative to network
element.
index O Proprietary method of
specifying a bin.
locn O Location
mon-dat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
mon-time M Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype O Monitored parameter
monval O Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
time-period O Accumulation time
period of data.
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..12]-ALL
T12) OTDRCFGALL
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..24]-ALL
T24) OTDRCFGALL
OTDRCFG All Slots OTDRCFG-shelf-ALL OTDRCFG-[0..992]-ALL
OTDRCFGALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype EVCSH-OTS Event Count Short
EVCSHMAX-OTS Event Count Short -
MAX
EVCLG-OTS Event Count Long
EVCLGMAX-OTS Event Count Long -
MAX
MAXEVLDISSH-OTS Maximum Event Loss
Distance Short
MAXEVLDISSHMAX-OTS Maximum Event Loss
Distance Short - MAX
MAXEVLDISLG-OTS Maximum Event Loss
Distance Long
MAXEVLDISLGMAX-OTS Maximum Event Loss
Distance Long - MAX
MAXEVRDISSH-OTS Maximum Event
Reflection Distance
Short
MAXEVRDISSHMAX-OTS Maximum Event
Reflection Distance
Short - MAX
MAXEVRDISLG-OTS Maximum Event
Reflection Distance
Long
MAXEVRDISLGMAX-OTS Maximum Event
Reflection Distance
Long - MAX
MAXEVLSH-OTS Maximum Event Loss
Short
MAXEVLSHMAX-OTS Maximum Event Loss
Short - MAX
MAXEVLLG-OTS Maximum Event Loss
Long
MAXEVLLGMAX-OTS Maximum Event Loss
Long - MAX
MAXEVRSH-OTS Maximum Event
Reflection Short
MAXEVRSHMAX-OTS Maximum Event
Reflection Short - MAX
MAXEVRLG-OTS Maximum Event
Reflection Long
MAXEVRLGMAX-OTS Maximum Event
Reflection Long - MAX
CUMEVLSH-OTS Cumulative Event Loss
Short
CUMEVLSHMAX-OTS Cumulative Event Loss
Short MAX
CUMEVLLG-OTS Cumulative Event Loss
Long
CUMEVLLGMAX-OTS Cumulative Event Loss
Long MAX
CUMEVRSH-OTS Cumulative Event
Reflection Short
CUMEVRSHMAX-OTS Cumulative Event
Reflection Short MAX
CUMEVRLG-OTS Cumulative Event
Reflection Long
CUMEVRLGMAX-OTS Cumulative Event
Reflection Long MAX
ALL
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..12]-ALL
T12) OTDRCFGALL
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..24]-ALL
T24) OTDRCFGALL
OTDRCFG All Slots OTDRCFG-shelf-ALL OTDRCFG-[0..992]-ALL
OTDRCFGALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
montype MAXEVLSH-OTS Maximum Event Loss
Short
MAXEVLLG-OTS Maximum Event Loss
Long
MAXEVRSH-OTS Maximum Event
Reflection Short
MAXEVRLG-OTS Maximum Event
Reflection Long
CUMEVLSH-OTS Cumulative Event Loss
Short
CUMEVLLG-OTS Cumulative Event Loss
Long
CUMEVRSH-OTS Cumulative Event
Reflection Short
CUMEVRLG-OTS Cumulative Event
Reflection Long
ALL
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 1-UNT
ALL
dest-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..12]-[5,8,13..14]
T12)
RLA OTDRCFG (6500- OTDRCFG-shelf-slot-port OTDRCFG-[0..992]-[1..24]-[5,8,13..14]
T24)
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..12]-ALL
T12) OTDRCFGALL
OTDRCFG All Ports (6500- OTDRCFG-shelf-slot-ALL OTDRCFG-[0..992]-[1..24]-ALL
T24) OTDRCFGALL
OTDRCFG All Slots OTDRCFG-shelf-ALL OTDRCFG-[0..992]-ALL
OTDRCFGALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
ALL objects ALL ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prfl-info Y
N
src-prfl-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
otdrcfg M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
montype O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
src-prfl-id O Source profile ID
AID Descriptions
AID Type Format Values
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6]-[1..194]-
(6500 7 Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..8]-[1..194]-
(6500 7 PKT-OPT) frequency [0..196131250]
NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6,9..14]-[1..194]-
(6500 14-Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-
(6500 32-Slot) frequency [1..8,11..18,21..28,31..38]-[1..194]-
[0..196131250]
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[25..27,29..32]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
OPT) frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) frequency [0..196131250]
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[51..82]-[1..194]-
frequency [0..196131250]
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..2]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..7]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
ALL PORTS NMCMON NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..14]-ALL
SPAP) NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
OPT) NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6,9..14]-[1..194]-
FREQ (6500 14-Slot) ALL
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-
FREQ (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
OPT) [1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) ALL
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL SLOTS NMCMON-shelf-ALL NMCMON-[0..992]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
ALL objects ALL ALL
All components on a shelf SHELF-shelf-ALL SHELF-[0..992]-ALL
SHELF-[0..992]-ALL
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
mon-type OPT-OCH Optical Channel Power
Transmit.
OPTMIN-OCH Optical Channel Power
Transmit Minimum.
OPTMAX-OCH Optical Channel Power
Transmit Maximum.
OPTAVG-OCH Optical Channel Power
Transmit Average.
ALL
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
nmcmonaid M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O L R The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
portmode O Optical Port market
preference
tmper M L Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6]-[1..194]-
(6500 7 Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..8]-[1..194]-
(6500 7 PKT-OPT) frequency [0..196131250]
NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6,9..14]-[1..194]-
(6500 14-Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-
(6500 32-Slot) frequency [1..8,11..18,21..28,31..38]-[1..194]-
[0..196131250]
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[25..27,29..32]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
OPT) frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) frequency [0..196131250]
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[51..82]-[1..194]-
frequency [0..196131250]
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..2]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..7]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
ALL PORTS NMCMON NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..14]-ALL
SPAP) NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
OPT) NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6,9..14]-[1..194]-
FREQ (6500 14-Slot) ALL
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-
FREQ (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
OPT) [1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) ALL
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL SLOTS NMCMON-shelf-ALL NMCMON-[0..992]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. HH =
00..23, MM =
00,15,30,45
montype ALL
monval string The value of the
monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6]-[1..194]-
(6500 7 Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..8]-[1..194]-
(6500 7 PKT-OPT) frequency [0..196131250]
NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6,9..14]-[1..194]-
(6500 14-Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-
(6500 32-Slot) frequency [1..8,11..18,21..28,31..38]-[1..194]-
[0..196131250]
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[25..27,29..32]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
OPT) frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) frequency [0..196131250]
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[51..82]-[1..194]-
frequency [0..196131250]
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..2]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..7]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
ALL PORTS NMCMON NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..14]-ALL
SPAP) NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
OPT) NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6,9..14]-[1..194]-
FREQ (6500 14-Slot) ALL
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-
FREQ (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
OPT) [1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) ALL
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL SLOTS NMCMON-shelf-ALL NMCMON-[0..992]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn NA Not Applicable
RCV Receive direction only
TRMT Transmit direction only
ALL Both directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type OPT-OCH Optical Channel Power
Transmit.
ALL
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 1-UNT, ALL Accumulation time
period of data.
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6]-[1..194]-
(6500 7 Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..8]-[1..194]-
(6500 7 PKT-OPT) frequency [0..196131250]
NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-[1..6,9..14]-[1..194]-
(6500 14-Slot) frequency [0..196131250]
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON NMCMON-shelf-slot-port- NMCMON-[0..992]-
(6500 32-Slot) frequency [1..8,11..18,21..28,31..38]-[1..194]-
[0..196131250]
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[25..27,29..32]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..86,91..99]-
OPT) frequency [1..194]-[0..196131250]
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port- NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) frequency [0..196131250]
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port- NMCMON-[0..992]-[51..82]-[1..194]-
frequency [0..196131250]
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..2]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..7]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
ALL PORTS NMCMON NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[1..14]-ALL
SPAP) NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-
(6500 32-Slot) [1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL PORTS NMCMON-shelf-slot-ALL NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..86,91..99]-ALL
OPT) NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-ALL NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-ALL NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6]-[1..194]-ALL
NMCMON-[0..992]-[1..6]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..8]-[1..194]-ALL
NMCMON-[0..992]-[1..8]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[1..6,9..14]-[1..194]-
FREQ (6500 14-Slot) ALL
NMCMON-[0..992]-[1..6,9..14]-[1..194]-
ALL
NMCMON-[0..992]-[1..6,9..14]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
FLEXGRID NMCMON ALL NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-
FREQ (6500 32-Slot) [1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-[1..194]-ALL
NMCMON-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 2-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-
[1..194]-ALL
NMCMON-[0..992]-[25..27,29..32]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 7 PKT- NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..86,91..99]-
OPT) [1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-
[1..194]-ALL
NMCMON-[0..992]-[83..86,91..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 14 Slot / NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[83..99]-[1..194]-
2-Slot SPAP) ALL
NMCMON-[0..992]-[83..99]-[1..194]-
ALL
NMCMON-[0..992]-[83..99]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON (6500 32-Slot) NMCMON-shelf-slot-port-ALL NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-[1..194]-
ALL
NMCMON-[0..992]-[51..82]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
NMCMON ALL SLOTS NMCMON-shelf-ALL NMCMON-[0..992]-ALL
NMCMON-[0..992]-ALL
NMCMONALL
SHELF SHELF-shelf SHELF-[0..992]
SHELFALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo Y
N
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
Syntax Definition
Parameter Attributes Description Notes
aidtype O Type of AID
nmcmon M aid n/a
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O Monitored parameter
thlev O Threshold level
tmper O Accumulation time
period of data.
src-profile-id O
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP-[0..992]-[1..12]-[1..40]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP-[0..992]-[1..24]-[1..40]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index 0 current interval
1 previous 1st interval
2 previous 2nd interval
3 previous 3rd interval
4 previous 4th interval
5 previous 5th interval
6 previous 6th interval
7 previous 7th interval
8 previous 8th interval
9 previous 9th interval
10 previous 10th interval
11 previous 11th interval
12 previous 12th interval
13 previous 13th interval
14 previous 14th interval
15 previous 15th interval
16 previous 16th interval
17 previous 17th interval
18 previous 18th interval
19 previous 19th interval
20 previous 20th interval
21 previous 21st interval
22 previous 22nd interval
23 previous 23rd interval
24 previous 24th interval
25 previous 25th interval
26 previous 26th interval
27 previous 27th interval
28 previous 28th interval
29 previous 29th interval
30 previous 30th interval
31 previous 31st interval
32 previous 32nd interval
ALL all intervals
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type OPR-OCH Optical Power Receive
- Optical Channel
OPT-OCH Optical Power
Transmit - Optical
Channel
OPRN-OCH Optical Power Receive
- Normalized - Optical
Channel
OPTN-OCH Optical Power
Transmit - Normalized
- Optical Channel
OPTAVG-OCH Average Optical Power
Transmit - Optical
Channel
OPTMIN-OCH Minimum Optical
Power Transmit -
Optical Channel
OPTMAX-OCH Maximum Optical
Power Transmit -
Optical Channel
DGDAVG-OCH Differential Group
Delay (Average) -
Optical Channel
DGDMAX-OCH Differential Group
Delay (Max) - Optical
Channel
OPRLOW-OCH Lowest optical power
received - Optical
Channel
OPTLOW-OCH Lowest optical power
transmitted - Optical
Channel
OPRNLOW-OCH Lowest optical power
received (normalized) -
Optical Channel
OPTNLOW-OCH Lowest optical power
transmitted
(normalized) - Optical
Channel
OPRHIGH-OCH Highest optical power
received - Optical
Channel
OPTHIGH-OCH Highest optical power
transmitted - Optical
Channel
OPRNHIGH-OCH Highest optical power
received (normalized) -
Optical Channel
OPTNHIGH-OCH Highest optical power
transmitted
(normalized) - Optical
Channel
OPRMIN-OCH Minimum Optical
Power Receive -
Optical Channel
OPRMAX-OCH Maximum Optical
Power Receive -
Optical Channel
OPRAVG-OCH Average Optical Power
Receive - Optical
Channel
OPR-OTS Optical Power
Received - Optical
Transport Section
OPRN-OTS Optical Power
Received (normalized)
- Optical Transport
Section
OPRMIN-OTS Total Optical Power
Received (Minimum) -
Optical Transport
Section
OPRMAX-OTS Total Optical Power
Received (Maximum) -
Optical Transport
Section
OPRAVG-OTS Total Optical Power
Received (Average) -
Optical Transport
Section
OPR-OTSI Optical Power
Receive- OTSI
OPT-OTSI Optical Power
Transmit- OTSI
OPRN-OTSI Normalized Optical
Power Receive- OTSI
OPTN-OTSI Normalized Optical
Power Transmit- OTSI
OPRAVG-OTSI Optical Power
Receive, Average -
OTSI
OPRMIN-OTSI Optical Power
Receive, Minimum -
OTSI
OPRMAX-OTSI Optical Power
Receive, Maximum -
OTSI
OPTAVG-OTSI Optical Power
Transmit, Average -
OTSI
OPTMIN-OTSI Optical Power
Transmit, Minimum -
OTSI
OPTMAX-OTSI Optical Power
Transmit, Maximum -
OTSI
DGDAVG-OTSI Differential Group
Delay (Average) OTSI
DGDMAX-OTSI Differential Group
Delay (Maximum)
OTSI
PDLAVG-OTSI Polarization
Dependent Loss,
Average - OTSI
PDLMAX-OTSI Polarization
Dependent Loss,
Maximum - OTSI
HCCS-OTSI High Correction Count
Seconds - OTSI
FEC-OTSI FEC Corrections -
OTSI
PRFBER-OTSI Post-FEC BER - OTSI
PRFBERMAX-OTSI Pre-FEC BER
Maximum - OTSI
QMIN-OTSI Q MIN - OTSI
QMAX-OTSI Q MAX - OTSI
QAVG-OTSI Q AVG - OTSI
QSTDEV-OTSI Q StDev - OTSI
UNCFECBLK-OTSI Uncorrected FEC
Block - OTSI
OSNRMIN-OTSI Optical Signal to Noise
Ratio (Minimum) OTSI
OSNRMAX-OTSI Optical Signal to Noise
Ratio (Maximum) OTSI
OSNRAVG-OTSI Optical Signal to Noise
Ratio (Average) OTSI
ESNRMIN-OTSI Electrical Signal to
Noise Ratio (Minimum)
OTSI
ESNRMAX-OTSI Electrical Signal to
Noise Ratio
(Maximum) OTSI
ESNRAVG-OTSI Electrical Signal to
Noise Ratio (Average)
OTSI
CDMIN-OTSI Dispersion
compensation
(Minimum) OTSI
CDMAX-OTSI Dispersion
compensation
(Maximum) OTSI
CDAVG-OTSI Dispersion
compensation
(Average) OTSI
PSCW-OTS Protection Switch
Count Working
PSCP-OTS Protection Switch
Count Protection
PSD-OTS Protection Switch
Duration
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
PDLAVG-OCH Polarization
Dependent Loss,
Average - OCH
PDLMAX-OCH Polarization
Dependent Loss,
Maximum - OCH
CDMIN-OCH Dispersion
compensation
(Minimum) OCH
CDMAX-OCH Dispersion
compensation
(Maximum) OCH
CDAVG-OCH Dispersion
compensation
(Average) OCH
CSIMIN-OTSI Cyclic Slip Indicator
(Minimum) - OTSi
CSIMAX-OTSI Cyclic Slip Indicator
(Maximum) - OTSi
CSIAVG-OTSI Cyclic Slip Indicator
(Average) - OTSi
SNREXTMIN-OTSI Signal to Noise Ratio
External (Minimum) -
OTSi
SNREXTMAX-OTSI Signal to Noise Ratio
External (Maximum) -
OTSi
SNREXTAVG-OTSI Signal to Noise Ratio
External (Average) -
OTSi
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file (a)The password
(inside quotes). cannot contain the
Example for IPv4 character '@'.
address: (b)Sample FTP URL
ftp://user:pass@xx.xx. with IPv4 address
xx.xx[:port]/path/filena ftp://userid:password@
me or xx.xx.xx.xx:port/path/fil
sftp://user:pass@xx.xx e (c)IPv6 address will
.xx.xx[:port]/path/filena be enclosed in [] for
me. Example for IPv6 e.g
address: ftp://userid:password@
ftp://user:pass@[abcd: [abcd:abcd:abcd:abcd:
abcd:abcd:abcd:abcd: abcd:abcd:abcd:abcd]:
abcd:abcd:abcd] port/path/file
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
ptp M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP-[0..992]-[1..12]-[1..40]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP-[0..992]-[1..24]-[1..40]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type OPR-OCH Optical Power Receive
- Optical Channel
OPT-OCH Optical Power
Transmit - Optical
Channel
OPRN-OCH Optical Power Receive
- Normalized - Optical
Channel
OPTN-OCH Optical Power
Transmit - Normalized
- Optical Channel
OPTAVG-OCH Average Optical Power
Transmit - Optical
Channel
OPTMIN-OCH Minimum Optical
Power Transmit -
Optical Channel
OPTMAX-OCH Maximum Optical
Power Transmit -
Optical Channel
DGDAVG-OCH Differential Group
Delay (Average) -
Optical Channel
DGDMAX-OCH Differential Group
Delay (Max) - Optical
Channel
OPRLOW-OCH Lowest optical power
received - Optical
Channel
OPTLOW-OCH Lowest optical power
transmitted - Optical
Channel
OPRNLOW-OCH Lowest optical power
received (normalized) -
Optical Channel
OPTNLOW-OCH Lowest optical power
transmitted
(normalized) - Optical
Channel
OPRHIGH-OCH Highest optical power
received - Optical
Channel
OPTHIGH-OCH Highest optical power
transmitted - Optical
Channel
OPRNHIGH-OCH Highest optical power
received (normalized) -
Optical Channel
OPTNHIGH-OCH Highest optical power
transmitted
(normalized) - Optical
Channel
OPRMIN-OCH Minimum Optical
Power Receive -
Optical Channel
OPRMAX-OCH Maximum Optical
Power Receive -
Optical Channel
OPRAVG-OCH Average Optical Power
Receive - Optical
Channel
OPR-OTS Optical Power
Received - Optical
Transport Section
OPRN-OTS Optical Power
Received (normalized)
- Optical Transport
Section
OPRMIN-OTS Total Optical Power
Received (Minimum) -
Optical Transport
Section
OPRMAX-OTS Total Optical Power
Received (Maximum) -
Optical Transport
Section
OPRAVG-OTS Total Optical Power
Received (Average) -
Optical Transport
Section
OPR-OTSI Optical Power
Receive- OTSI
OPT-OTSI Optical Power
Transmit- OTSI
OPRN-OTSI Normalized Optical
Power Receive- OTSI
OPTN-OTSI Normalized Optical
Power Transmit- OTSI
OPRAVG-OTSI Optical Power
Receive, Average -
OTSI
OPRMIN-OTSI Optical Power
Receive, Minimum -
OTSI
OPRMAX-OTSI Optical Power
Receive, Maximum -
OTSI
OPTAVG-OTSI Optical Power
Transmit, Average -
OTSI
OPTMIN-OTSI Optical Power
Transmit, Minimum -
OTSI
OPTMAX-OTSI Optical Power
Transmit, Maximum -
OTSI
DGDAVG-OTSI Differential Group
Delay (Average) OTSI
DGDMAX-OTSI Differential Group
Delay (Maximum)
OTSI
PDLAVG-OTSI Polarization
Dependent Loss,
Average - OTSI
PDLMAX-OTSI Polarization
Dependent Loss,
Maximum - OTSI
HCCS-OTSI High Correction Count
Seconds - OTSI
FEC-OTSI FEC Corrections -
OTSI
PRFBER-OTSI Post-FEC BER - OTSI
PRFBERMAX-OTSI Pre-FEC BER
Maximum - OTSI
QMIN-OTSI Q MIN - OTSI
QMAX-OTSI Q MAX - OTSI
QAVG-OTSI Q AVG - OTSI
QSTDEV-OTSI Q StDev - OTSI
UNCFECBLK-OTSI Uncorrected FEC
Block - OTSI
OSNRMIN-OTSI Optical Signal to Noise
Ratio (Minimum) OTSI
OSNRMAX-OTSI Optical Signal to Noise
Ratio (Maximum) OTSI
OSNRAVG-OTSI Optical Signal to Noise
Ratio (Average) OTSI
ESNRMIN-OTSI Electrical Signal to
Noise Ratio (Minimum)
OTSI
ESNRMAX-OTSI Electrical Signal to
Noise Ratio
(Maximum) OTSI
ESNRAVG-OTSI Electrical Signal to
Noise Ratio (Average)
OTSI
CDMIN-OTSI Dispersion
compensation
(Minimum) OTSI
CDMAX-OTSI Dispersion
compensation
(Maximum) OTSI
CDAVG-OTSI Dispersion
compensation
(Average) OTSI
PSCW-OTS Protection Switch
Count Working
PSCP-OTS Protection Switch
Count Protection
PSD-OTS Protection Switch
Duration
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
PDLAVG-OCH Polarization
Dependent Loss,
Average - OCH
PDLMAX-OCH Polarization
Dependent Loss,
Maximum - OCH
CDMIN-OCH Dispersion
compensation
(Minimum) OCH
CDMAX-OCH Dispersion
compensation
(Maximum) OCH
CDAVG-OCH Dispersion
compensation
(Average) OCH
CSIMIN-OTSI Cyclic Slip Indicator
(Minimum) - OTSi
CSIMAX-OTSI Cyclic Slip Indicator
(Maximum) - OTSi
CSIAVG-OTSI Cyclic Slip Indicator
(Average) - OTSi
SNREXTMIN-OTSI Signal to Noise Ratio
External (Minimum) -
OTSi
SNREXTMAX-OTSI Signal to Noise Ratio
External (Maximum) -
OTSi
SNREXTAVG-OTSI Signal to Noise Ratio
External (Average) -
OTSi
ALL All applicable valid only as an input
montypes parameter
monval 0 Reset baselines Reset power to a new
baseline value
INIT Init baselines Clear current baseline
value
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP-[0..992]-[1..12]-[1..40]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP-[0..992]-[1..24]-[1..40]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type OPR-OCH Optical Power Receive
- Optical Channel
OPT-OCH Optical Power
Transmit - Optical
Channel
OPRN-OCH Optical Power Receive
- Normalized - Optical
Channel
OPTAVG-OCH Average Optical Power
Transmit - Optical
Channel
OPTMIN-OCH Minimum Optical
Power Transmit -
Optical Channel
OPTMAX-OCH Maximum Optical
Power Transmit -
Optical Channel
DGDAVG-OCH Differential Group
Delay (Average) -
Optical Channel
DGDMAX-OCH Differential Group
Delay (Max) - Optical
Channel
OPRLOW-OCH Lowest optical power
received - Optical
Channel
OPTLOW-OCH Lowest optical power
transmitted - Optical
Channel
OPRNLOW-OCH Lowest optical power
received (normalized) -
Optical Channel
OPRHIGH-OCH Highest optical power
received - Optical
Channel
OPTHIGH-OCH Highest optical power
transmitted - Optical
Channel
OPRNHIGH-OCH Highest optical power
received (normalized) -
Optical Channel
OPRAVG-OCH Average Optical Power
Receive - Optical
Channel
OPRMIN-OCH Minimum Optical
Power Receive -
Optical Channel
OPRMAX-OCH Maximum Optical
Power Receive -
Optical Channel
OPR-OTS Optical Power
Received - Optical
Transport Section
OPRN-OTS Optical Power
Received (normalized)
- Optical Transport
Section
OPR-OTSI Optical Power
Receive- OTSI
OPT-OTSI Optical Power
Transmit- OTSI
OPRN-OTSI Normalized Optical
Power Receive- OTSI
DGDAVG-OTSI Differential Group
Delay (Average) OTSI
DGDMAX-OTSI Differential Group
Delay (Maximum)
OTSI
PDLAVG-OTSI Polarization
Dependent Loss,
Average - OTSI
PDLMAX-OTSI Polarization
Dependent Loss,
Maximum - OTSI
HCCS-OTSI High Correction Count
Seconds - OTSI
PRFBER-OTSI Post-FEC BER - OTSI
PRFBERMAX-OTSI Pre-FEC BER
Maximum - OTSI
QMIN-OTSI Q MIN - OTSI
QMAX-OTSI Q MAX - OTSI
QAVG-OTSI Q AVG - OTSI
QSTDEV-OTSI Q StDev - OTSI
UNCFECBLK-OTSI Uncorrected FEC
Block - OTSI
OSNRMIN-OTSI Optical Signal to Noise
Ratio (Minimum) OTSI
OSNRMAX-OTSI Optical Signal to Noise
Ratio (Maximum) OTSI
OSNRAVG-OTSI Optical Signal to Noise
Ratio (Average) OTSI
ESNRMIN-OTSI Electrical Signal to
Noise Ratio (Minimum)
OTSI
ESNRMAX-OTSI Electrical Signal to
Noise Ratio
(Maximum) OTSI
ESNRAVG-OTSI Electrical Signal to
Noise Ratio (Average)
OTSI
CDMIN-OTSI Dispersion
compensation
(Minimum) OTSI
CDMAX-OTSI Dispersion
compensation
(Maximum) OTSI
CDAVG-OTSI Dispersion
compensation
(Average) OTSI
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
PDLAVG-OCH Polarization
Dependent Loss,
Average - OCH
PDLMAX-OCH Polarization
Dependent Loss,
Maximum - OCH
CDMIN-OCH Dispersion
compensation
(Minimum) OCH
CDMAX-OCH Dispersion
compensation
(Maximum) OCH
CDAVG-OCH Dispersion
compensation
(Average) OCH
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..12]-[1..40]S[1..4]
PTP-[0..992]-[1..12]-[1..40]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-portSsubport PTP-[0..992]-[1..24]-[1..40]S[1..4]
PTP-[0..992]-[1..24]-[1..40]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..12]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot- PTP-[0..992]-[1..24]S[1..3]-[1..5]S[1..4]
portSsubport PTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
ptp M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-profile-id M Source profile ID
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype O aidtype
ptp M aid
hccs-ref O Floating point value
representing the
margin in dBQ relative
to a post FEC BER of
1E-15.
AID Descriptions
AID Type Format Values
PTP (6500-T12) PTP-shelf-slot-port PTP-[0..992]-[1..12]-[1..40]
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slot-port PTP-[0..992]-[1..24]-[1..40]
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
PTP (6500-T12) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..12]S[1..3]-[1..12]
PTP-[0..992]-[1..12]S[1..3]-ALL
PTP-[0..992]-[1..12]-ALL
PTP-[0..992]-ALL
PTP (6500-T24) PTP-shelf-slotSsubslot-port PTP-[0..992]-[1..24]S[1..3]-[1..12]
PTP-[0..992]-[1..24]S[1..3]-ALL
PTP-[0..992]-[1..24]-ALL
PTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
hccs-ref string Floating point value
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTUTTP-[0..992]-[1..2]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTUTTP-[0..992]-[1..7]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTUTTP-[0..992]-[1..6]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTUTTP-[0..992]-[1..6,9..14]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type CV-OTU Coding Violations -
OTU
ES-OTU Errored Seconds -
OTU
SES-OTU Severely Errored
Seconds - OTU
SEFS-OTU Severely Errored
Framing Seconds -
OTU
FEC-OTU Forward Error
Corrections - OTU
HCCS-OTU High Correction Count
Seconds - OTU
PFBERE-OTU Post-FEC Bit Error
Rate Estimate - OTU
PRFBER-OTU Pre-FEC Bit Error Rate
- OTU
PRFBERMAX-OTU Pre-FEC Bit Max Error
Rate - OTU
IAE-OTU Incoming Alignment
Error - OTU
QMIN-OTU Minimum Q - OTU
QMAX-OTU Maximum Q - OTU
QAVG-OTU Average Q - OTU
QSTDEV-OTU Q Standard Deviation -
OTU
UNCFECBLK-OTU Uncorrected FEC
Block - OTU
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file (a)The password
(inside quotes). cannot contain the
Example for IPv4 character '@'.
address: (b)Sample FTP URL
ftp://user:pass@xx.xx. with IPv4 address
xx.xx[:port]/path/filena ftp://userid:password@
me or xx.xx.xx.xx:port/path/fil
sftp://user:pass@xx.xx e (c)IPv6 address will
.xx.xx[:port]/path/filena be enclosed in [] for
me. Example for IPv6 e.g
address: ftp://userid:password@
ftp://user:pass@[abcd: [abcd:abcd:abcd:abcd:
abcd:abcd:abcd:abcd: abcd:abcd:abcd:abcd]:
abcd:abcd:abcd] port/path/file
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
otuttp M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTUTTP-[0..992]-[1..2]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTUTTP-[0..992]-[1..7]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTUTTP-[0..992]-[1..6]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTUTTP-[0..992]-[1..6,9..14]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type CV-OTU Coding Violations -
OTU
ES-OTU Errored Seconds -
OTU
SES-OTU Severely Errored
Seconds - OTU
SEFS-OTU Severely Errored
Framing Seconds -
OTU
FEC-OTU Forward Error
Corrections - OTU
HCCS-OTU High Correction Count
Seconds - OTU
PFBERE-OTU Post-FEC Bit Error
Rate Estimate - OTU
PRFBER-OTU Pre-FEC Bit Error Rate
- OTU
PRFBERMAX-OTU Pre-FEC Bit Max Error
Rate - OTU
IAE-OTU Incoming Alignment
Error - OTU
QMIN-OTU Minimum Q - OTU
QMAX-OTU Maximum Q - OTU
QAVG-OTU Average Q - OTU
QSTDEV-OTU Q Standard Deviation -
OTU
UNCFECBLK-OTU Uncorrected FEC
Block - OTU
ALL All applicable valid only as an input
montypes parameter
monval INT The value of the
(0) monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTUTTP-[0..992]-[1..2]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTUTTP-[0..992]-[1..7]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTUTTP-[0..992]-[1..6]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTUTTP-[0..992]-[1..6,9..14]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
port
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
mon-type CV-OTU Coding Violations -
OTU
ES-OTU Errored Seconds -
OTU
SES-OTU Severely Errored
Seconds - OTU
SEFS-OTU Severely Errored
Framing Seconds -
OTU
HCCS-OTU High Correction Count
Seconds - OTU
PFBERE-OTU Post-FEC Bit Error
Rate Estimate - OTU
PRFBER-OTU Pre-FEC Bit Error Rate
- OTU
PRFBERMAX-OTU Pre-FEC Bit Max Error
Rate - OTU
IAE-OTU Incoming Alignment
Error - OTU
UNCFECBLK-OTU Uncorrected FEC
Block - OTU
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 2-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..2]-[1..44]
OTUTTP-[0..992]-[1..2]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..7]-[1..44]
OTUTTP-[0..992]-[1..7]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 7 PKT-OPT) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6]-[1..44]
OTUTTP-[0..992]-[1..6]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 14-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..6,9..14]-[1..44]
OTUTTP-[0..992]-[1..6,9..14]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 32-Slot) OTUTTP-shelf-slot-port OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-[1..44]
OTUTTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
otuttp M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
mon-type O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-profile-id M Source profile ID
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
ALL ALL ALL
Syntax Definition
Parameter Attributes Description Notes
aidtype O aidtype
otuttp M aid
hccs-ref O Floating point value
representing the
margin in dBQ relative
to a post FEC BER of
1E-15.
AID Descriptions
AID Type Format Values
OTU (6500-T12) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..12]-[1..40]
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot-port OTUTTP-[0..992]-[1..24]-[1..40]
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..12]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..12]-[1..40]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slot- OTUTTP-[0..992]-[1..24]-[1..40]S[1..4]
portSsubport OTUTTP-[0..992]-[1..24]-[1..40]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..12]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500-T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
OTUTTP-[0..992]-[1..24]S[1..3]-[1..5]-
ALL
OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T12) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..12]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..12]S[1..3]-ALL
OTUTTP-[0..992]-[1..12]-ALL
OTUTTP-[0..992]-ALL
OTU (6500 T24) OTUTTP-shelf-slotSsubslot- OTUTTP-[0..992]-[1..24]S[1..3]-[1..12]
port OTUTTP-[0..992]-[1..24]S[1..3]-ALL
OTUTTP-[0..992]-[1..24]-ALL
OTUTTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
hccs-ref string Floating point value
AID Descriptions
AID Type Format Values
STTP (6500-T12) STTP-shelf-slot-port STTP-[0..992]-[1..12]-[1..40]
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 2-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..2]-[2..44]
STTP-[0..992]-[1..2]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..7]-[2..44]
STTP-[0..992]-[1..7]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7 PKT- STTP-shelf-slot-port STTP-[0..992]-[1..6]-[2..44]
OPT) STTP-[0..992]-[1..6]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 14-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..6,9..14]-[2..44]
STTP-[0..992]-[1..6,9..14]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 32-Slot) STTP-shelf-slot-port STTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
STTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..12]S[1..3]-[1..12]
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..24]S[1..3]-[1..12]
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
ALL All ends
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file (a)The password
(inside quotes). cannot contain the
Example for IPv4 character '@'.
address: (b)Sample FTP URL
ftp://user:pass@xx.xx. with IPv4 address
xx.xx[:port]/path/filena ftp://userid:password@
me or xx.xx.xx.xx:port/path/fil
sftp://user:pass@xx.xx e (c)IPv6 address will
.xx.xx[:port]/path/filena be enclosed in [] for
me. Example for IPv6 e.g
address: ftp://userid:password@
ftp://user:pass@[abcd: [abcd:abcd:abcd:abcd:
abcd:abcd:abcd:abcd: abcd:abcd:abcd:abcd]:
abcd:abcd:abcd] port/path/file
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
sttp M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 2-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..2]-[2..44]
STTP-[0..992]-[1..2]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..7]-[2..44]
STTP-[0..992]-[1..7]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7 PKT- STTP-shelf-slot-port STTP-[0..992]-[1..6]-[2..44]
OPT) STTP-[0..992]-[1..6]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 14-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..6,9..14]-[2..44]
STTP-[0..992]-[1..6,9..14]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 32-Slot) STTP-shelf-slot-port STTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
STTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..12]S[1..3]-[1..12]
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..24]S[1..3]-[1..12]
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
FC-L Failure Count - Line
ALL All ends
monval INT The value of the
(0) monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
STTP (6500-T12) STTP-shelf-slot-port STTP-[0..992]-[1..12]-[1..40]
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 2-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..2]-[2..44]
STTP-[0..992]-[1..2]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..7]-[2..44]
STTP-[0..992]-[1..7]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7 PKT- STTP-shelf-slot-port STTP-[0..992]-[1..6]-[2..44]
OPT) STTP-[0..992]-[1..6]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 14-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..6,9..14]-[2..44]
STTP-[0..992]-[1..6,9..14]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 32-Slot) STTP-shelf-slot-port STTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
STTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..12]S[1..3]-[1..12]
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..24]S[1..3]-[1..12]
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type CV-S Coding Violations -
Section
ES-S Errored Seconds -
Section
SES-S Severely Errored
Seconds - Section
SEFS-S Severely Errored
Frame Seconds -
Section
CV-L Coding Violations -
Line
ES-L Errored Seconds - Line
SES-L Severely Errored
Seconds - Line
UAS-L Unavailable Seconds -
Line
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
STTP (6500-T12) STTP-shelf-slot-port STTP-[0..992]-[1..12]-[1..40]
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slot-port STTP-[0..992]-[1..24]-[1..40]
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 2-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..2]-[2..44]
STTP-[0..992]-[1..2]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..7]-[2..44]
STTP-[0..992]-[1..7]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 7 PKT- STTP-shelf-slot-port STTP-[0..992]-[1..6]-[2..44]
OPT) STTP-[0..992]-[1..6]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 14-Slot) STTP-shelf-slot-port STTP-[0..992]-[1..6,9..14]-[2..44]
STTP-[0..992]-[1..6,9..14]-ALL
STTP-[0..992]-ALL
WL AI STTP (6500 32-Slot) STTP-shelf-slot-port STTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
STTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T12) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..12]S[1..3]-[1..12]
STTP-[0..992]-[1..12]S[1..3]-ALL
STTP-[0..992]-[1..12]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot- STTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
STTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
STTP (6500-T24) STTP-shelf-slotSsubslot-port STTP-[0..992]-[1..24]S[1..3]-[1..12]
STTP-[0..992]-[1..24]S[1..3]-ALL
STTP-[0..992]-[1..24]-ALL
STTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
sttp M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-profile-id M Source profile ID
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
monlev 0-UP
1-UP
0-ADJ-UP
montm string Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type CV-PCS Coding Violations -
Physical Coding
Sublayer
ES-PCS Errored Seconds -
Physical Coding
Sublayer
SES-PCS Severely Errored
Seconds - Physical
Coding Sublayer
UAS-PCS Unavailable Seconds -
Physical Coding
Sublayer
ES-E ETH Errored seconds
(RX)
SES-E ETH Severely Errored
Seconds (Rx)
UAS-E ETH Unavailable
Seconds (Rx)
FEC-PMA Forward Error
Corrections - Physical
Medium Attachment
FECCCW-PMA Forward Error
Corrections Corrected
Codewords - Physical
Medium Attachment
FECUNCCW-PMA Forward Error
Corrections
Uncorrected
Codewords - Physical
Medium Attachment
HCCS-PMA High Correction Count
Second - Physical
Medium Attachment
PRFBER-PMA Pre-FEC Bit Error Rate
(Average) - Physical
Medium Attachment
PRFBERMAX-PMA Pre-FEC Bit Error Rate
Maximum - Physical
Medium Attachment
INFRAMES-E Total ETH frames
received
INFRAMESERR-E Total ETH frames Includes all frames
received with errors with LAN FCS errors
(including fragments
and jabbers)
INFRAMESDISCDS-E Ingress frames
discarded due to
congestion or policing
DFR-E Total frames discarded Eg:undersized frames,
for any reason other and frames containing
than FCS errors (Rx unknown VCE ID.
and Tx)
OUTFRAMES-E Total ETH frames
transmitted
OUTFRAMESERR-E Total egress direction Not applicable to L2SS
ETH frames
transmitted with FCS
errors
OUTFRAMESDISCDS-E Egress frames Not applicable to L2SS
discarded due to
congestion or policing
FCSERR-E Frame Check
Sequence Errors
ALL All applicable valid only as an input
montypes parameter
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
trexfrmt GZIP GZIP format
trexurl string Full URL to remote file (a)The password
(inside quotes). cannot contain the
Example for IPv4 character '@'.
address: (b)Sample FTP URL
ftp://user:pass@xx.xx. with IPv4 address
xx.xx[:port]/path/filena ftp://userid:password@
me or xx.xx.xx.xx:port/path/fil
sftp://user:pass@xx.xx e (c)IPv6 address will
.xx.xx[:port]/path/filena be enclosed in [] for
me. Example for IPv6 e.g
address: ftp://userid:password@
ftp://user:pass@[abcd: [abcd:abcd:abcd:abcd:
abcd:abcd:abcd:abcd: abcd:abcd:abcd:abcd]:
abcd:abcd:abcd] port/path/file
[:port]/path/filename or
sftp://user:pass@[abcd
:abcd:abcd:abcd:abcd:
abcd:abcd:abcd]
[:port]/path/filename.
IPv6 address must be
enclosed in []. The
password cannot
contain the character
'@'.
Syntax Definition
Parameter Attributes Description Notes
aidtype O AID type
ettp M aid
altaid O A physical location
identifier for a facility
consisting of a Bay
and Shelf identifier.
channelid O logical channel number
assignment for each
defined wavelength.
Range 1 - 96.
channelstatus O Unknown, InUse
(managed by DOC),
and Idle (not managed
by DOC).
dirn M Direction of signal flow
relative to network
element.
index O The interval numbers If mondat or montm is
to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn M Location
mondat M Nominal Start date of
monitoring interval
(MM-DD) or ALL. MM
= 01..12, DD = 01..31
montm M Nominal Start time of
monitoring level (HH-
MM) or ALL. Hour =
00..23, Minute =
00,15,30,45
mon-type M Monitored parameter
monval M Discriminating Level
for requested
monitored parameter.
port-mode O Optical Port market
preference
tmper M Accumulation time
period of data
vldty O Validity indicator for
historical monitoring
information. It indicates
whether the
information for the
specified time period
was accumulated over
the entire time period
or some portion of it.
wavelength O Channel wavelength.
width O Channel width.
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
index INT The interval numbers If mondat or montm is
(0-32) to be accessed. 0 = used, index cannot be
current interval; 1-32 = used.
previous intervals e.g.
for tmper=15-MIN,
index=1 is the most
recently completed 15-
minute interval,
index=2 is the interval
before that. For
tmper=1-DAY, index=1
is the most recently
completed day interval
(yesterday); ALL = all
intervals.
locn NEND Near End
FEND Far End
ALL All ends
mondat string (Nominal) Start date of
monitoring interval
(MM-DD).
montm string Nominal start time of
monitoring level. HH-
MM. Range = 00-00 to
23-59.
mon-type CV-PCS Coding Violations -
Physical Coding
Sublayer
ES-PCS Errored Seconds -
Physical Coding
Sublayer
SES-PCS Severely Errored
Seconds - Physical
Coding Sublayer
UAS-PCS Unavailable Seconds -
Physical Coding
Sublayer
ES-E ETH Errored seconds
(RX)
SES-E ETH Severely Errored
Seconds (Rx)
UAS-E ETH Unavailable
Seconds (Rx)
FEC-PMA Forward Error
Corrections - Physical
Medium Attachment
FECCCW-PMA Forward Error
Corrections Corrected
Codewords - Physical
Medium Attachment
FECUNCCW-PMA Forward Error
Corrections
Uncorrected
Codewords - Physical
Medium Attachment
HCCS-PMA High Correction Count
Second - Physical
Medium Attachment
PRFBER-PMA Pre-FEC Bit Error Rate
(Average) - Physical
Medium Attachment
PRFBERMAX-PMA Pre-FEC Bit Error Rate
Maximum - Physical
Medium Attachment
INFRAMES-E Total ETH frames
received
INFRAMESERR-E Total ETH frames Includes all frames
received with errors with LAN FCS errors
(including fragments
and jabbers)
INFRAMESDISCDS-E Ingress frames
discarded due to
congestion or policing
DFR-E Total frames discarded Eg:undersized frames,
for any reason other and frames containing
than FCS errors (Rx unknown VCE ID.
and Tx)
OUTFRAMES-E Total ETH frames
transmitted
OUTFRAMESERR-E Total egress direction Not applicable to L2SS
ETH frames
transmitted with FCS
errors
OUTFRAMESDISCDS-E Egress frames Not applicable to L2SS
discarded due to
congestion or policing
FCSERR-E Frame Check
Sequence Errors
ALL All applicable valid only as an input
montypes parameter
monval INT The value of the
(0) monitored PM
parameter.
tmper 15-MIN
1-DAY
1-UNT
BASLN
ALL
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
dirn RCV Receive direction only
TRMT Transmit direction only
ALL All directions
locn NEND Near End
FEND Far End
ALL All ends
monitor-type ES-PCS Errored Seconds -
Physical Coding
Sublayer
SES-PCS Severely Errored
Seconds - Physical
Coding Sublayer
UAS-PCS Unavailable Seconds -
Physical Coding
Sublayer
ES-E ETH Errored seconds
(RX)
SES-E ETH Severely Errored
Seconds (Rx)
UAS-E ETH Unavailable
Seconds (Rx)
HCCS-PMA High Correction Count
Second - Physical
Medium Attachment
PRFBER-PMA Pre-FEC Bit Error Rate
(Average) - Physical
Medium Attachment
PRFBERMAX-PMA Pre-FEC Bit Error Rate
Maximum - Physical
Medium Attachment
thlev string This field must contain
the desired threshold
level to be set for
montype. This field
supports Non-negative
integers (0 = disable
threshold) and strings
to support scientific
notations such as 4E-
10
tmper 15-MIN
1-DAY
1-UNT
ALL
dest-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Destination
Profile
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT ALLOFF - ALL Source
Profiles OFF
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
AID Descriptions
AID Type Format Values
ETTP (6500-T12) ETTP-shelf-slot-port ETTP-[0..992]-[1..12]-[1..40]
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-port ETTP-[0..992]-[1..24]-[1..40]
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 2-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..2]-[2..44]
ETTP-[0..992]-[1..2]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..7]-[2..44]
ETTP-[0..992]-[1..7]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 7 PKT- ETTP-shelf-slot-port ETTP-[0..992]-[1..6]-[2..44]
OPT) ETTP-[0..992]-[1..6]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 14-Slot) ETTP-shelf-slot-port ETTP-[0..992]-[1..6,9..14]-[2..44]
ETTP-[0..992]-[1..6,9..14]-ALL
ETTP-[0..992]-ALL
WL AI ETTP (6500 32-Slot) ETTP-shelf-slot-port ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-[2..44]
ETTP-[0..992]-
[1..8,11..18,21..28,31..38]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..12]-[1..40]S[1..4]
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slot-portSsubport ETTP-[0..992]-[1..24]-[1..40]S[1..4]
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..12]S[1..3]-[1..12]
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport [1..5]S[1..4]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
ETTP (6500-T12) ETTP-shelf-slotSsubslot-port ETTP-[0..992]-[1..24]S[1..3]-[1..12]
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..12]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1 ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-
rt2Ptp2 [2,2E,3,4,CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]-
[2,2E,3,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-port-rt1Ptp1- ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
rt2Ptp2-rt3Ptp3 [0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]P[1]-
ALL
ETTP-[0..992]-[1..24]-[1..40]-[CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..12]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..12]-[1..40]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slot-portSsubport- ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
rt1Ptp1-rt2Ptp2 [2,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-
[2,4,CN]-ALL
ETTP-[0..992]-[1..24]-[1..40]S[1..4]-ALL
ETTP-[0..992]-[1..24]-[1..40]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..12]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,2E,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-[0,1,F,4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T12) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-[CN]-
ALL
ETTP-[0..992]-[1..12]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..12]S[1..3]-ALL
ETTP-[0..992]-[1..12]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1 [1..5]S[1..4]-[2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot- ETTP-[0..992]-[1..24]S[1..3]-
portSsubport-rt1Ptp1-rt2Ptp2 [1..5]S[1..4]-[2,4,CN]P[1]-
[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-[2,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-
[1..5]S[1..4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1 [2,2E,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [2,2E,4,CN]P[1]-[0,1,F,4]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-[0,1,F,4]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[2,2E,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [4]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1-rt2Ptp2 [4]P[1]-[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[4]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-[4]-
ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
rt1Ptp1 [3,4,CN]P[1]
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..5]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2 [3,4,CN]P[1]-[0,1,2,2E,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-[0,1,2,2E,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[3,4,CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
Mapped ETTP (6500-T24) ETTP-shelf-slotSsubslot-port- ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
rt1Ptp1-rt2Ptp2-rt3Ptp3 [CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]P[1..80]
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-
[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]P[1..80]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-[0,1,2,2E,3,4,F]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]P[1]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-
[CN]-ALL
ETTP-[0..992]-[1..24]S[1..3]-[1..12]-ALL
ETTP-[0..992]-[1..24]S[1..3]-ALL
ETTP-[0..992]-[1..24]-ALL
ETTP-[0..992]-ALL
SHELF SHELF-shelf SHELF-[0..992]
ALL ALL ALL
Input Parameter Description
Parameter Value Description Notes
prflinfo N do not list profile
information
Y list profile information
src-profile-id PROFILE1 PM Profile 1
PROFILE2 PM Profile 2
PROFILE3 PM Profile 3
PROFILE4 PM Profile 4
DFLT Default Source Profile
ALLOFF ALL PM Profiles OFF
FACTORYDFLT Factory DeFauLT PM
Profile
ALLPROFILES All Source Profiles
Syntax Definition
Parameter Attributes Description Notes
aidtype M AID type
ettp M aid
dirn O Direction of signal flow
relative to network
element.
locn O Location
monitor-type O monitored parameter.
thlev O The provisioned
threshold level for
montype
tmper O Accumulation time
period of data
src-profile-id M Source profile ID