The EN 50600 series

-
European
Data Centre
Standardisation

The EN 50600 series


-
European Data Centre
Standardisation

Mike Gilmore, e-Ready Building Limited

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Mike Gilmore
Standards Activities
The EN 50600 series
-
Member
European
JTC1 SC25 WG3: “Generic Cabling”
Data Centre
Leader
Standardisation
WG3 Cabling Implementation Task Group: ISO/IEC 14763-2
Meeting Secretary
WG3 Automated Infrastructure Management Ad-hoc: ISO/IEC 18598

Chairman
TC215
Electrotechnical Aspects of Telecommunication Equipment
Convenor
TC215 WG1: Cabling design
Meeting Secretary
Mike Gilmore, FIET
TC215 WG2: Cabling installation - QA and installation practices
Member
Managing Director
TC215 WG3: Facilities and infrastructures (data centres)
e-Ready Building Limited
Member
CEN/CLC/ETSI CG Green Data Centres
Mobile:
+44 (0)786 011 0563 Past-Chairman
e-mail: TCT/7: Telecommunications - Installation Requirements
mike.gilmore Chairman
@ TCT/7/1: Cabling: Infrastructure design, planning and commissioning
e-readybuilding.com Meeting Secretary
TCT/7/2: Cabling; Installation and UK implementation
FIA e-mail: TCT/7/3: Facilities and infrastructures
standards@fia-online.co.uk
Layer One
Greece Fibreoptic Industry Association Director
www.fia-online.co.uk standards@fia
9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Standardisation - Europe

The EN 50600 series EARLY WORK IN EUROPEAN STANDARDISATION


-
European
Data Centre CLC EN 50173-5:2007
Information technology: Generic cabling systems: Data centres
Standardisation +A1:2010+A2:2012

Energy Efficiency and Key Performance Indicators;


ETSI TR 105174-2-2:2009
Part 2: Network sites; Sub-part 2: Data centres

Energy management; Global KPIs; Operational infrastructures;


ETSI ES 205200-2-1:2013
Part 2: Specific requirements; Sub-part 1: Data centres

The implementation of data centres varies in terms of:


a) purpose (enterprise, co-location, co-hosting or network operator facilities);
COMMON
b) security level;
CONCLUSION
c) physical size;
d) accommodation (mobile, temporary and permanent constructions).

COMMON Small data centres ~99 % Large data centres ~1 %


RECOGNITION Dominate market Dominate market awareness

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Standardisation - Europe

The EN 50600 series COMMON DEFINITION IN EUROPE AND INTERNATIONAL STANDARDS


-
European structure, or group of structures, dedicated to the centralized accommodation, interconnection and
Data Centre operation of information technology and network telecommunications equipment providing data
Standardisation storage, processing and transport services together with all the facilities and infrastructures for
power distribution and environmental control together with the necessary levels of resilience and
security required to provide the desired service availability.
Note: a structure can consist of multiple buildings and/or spaces with specific functions to support the primary function.
Note: the boundaries of the structure or space considered the data centre which includes the information and communication
technology equipment and supporting environmental controls can be defined within a larger structure or building.

Data

Data Data
Data

not restricted to
allows data centres inside other types of premises
dedicated premises
not restricted to buildings allows caves, containers etc.

no size discrimination “comms rooms” to multi-floor “football fields”

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Standardisation - CENELEC

The EN 50600 series Information technology - Data centre facilities and infrastructures -
EN 50600-1:2012
- General requirements
European
Data Centre Energy efficiency
Availability Physical security
Standardisation enablement

Class 1 Zone 1 Level 1


Class 2 Zone 2 Level 2
Class 3 Zone 3 Level 3
Class 4 Zone 4

Protection against
• unauthorised access
• internal fire
• other internal environmental events
• external environmental events

Layer One EN 50600-2-x Design standards


Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Design Standards - CENELEC

The EN 50600 series


EN 50600-2-x Design standards
-
European
Data Centre
Standardisation
Information technology - Data centre facilities and infrastructures

EN 50600-2-1:2014 Building construction

EN 50600-2-2:2014 Power distribution

EN 50600-2-3:2014 Environmental control

EN 50600-2-4:2015 Telecommunications cabling infrastructure

EN 50600-2-5:2016 Security Systems

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
ISO/IEC Activity

The EN 50600 series Information Technology - Data Centres -


ISO/IEC 30134-x
- Key performance indicators
European
Data Centre
Standardisation
Resource management

ISO/IEC 30134-1:2016 General requirements

ISO/IEC 30134-2 :2016 Power Usage Effectiveness (PUE)

ISO/IEC 30134-3:2016 Renewal Energy Factor (REF)

ISO/IEC 30134-4:2016 IT Equipment Energy Efficiency for Servers (ITEESV)

ISO/IEC 30134-5:2016 IT Equipment Energy Utilisation for Servers (ITEESV)

These KPIs define measurement methods


-
NOT REQUIREMENTS FOR PERFORMANCE

Influenced by design and operation of data centres


-
but not linked to any standards for design or operation

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Key Performance Indicators

The EN 50600 series TECHNICAL KPI’S


-
... assessing energy consumption for a number of specific operating conditions and also across a
European
combination of such operating conditions
Data Centre
Standardisation
Assuming those operating conditions reflect the probable operating environment .. a customer may
make valued judgements in relation to the appropriateness of the Technical KPI

For example, a design of power supply that is more task efficient under high load conditions may be
inappropriate for users who plan to predominantly operate under low load conditions (and vice versa)

OBJECTIVE KPI’S
... relate to specific elements of energy management for operational infrastructures including:
energy consumption, task efficiency, energy re-use and renewable energy

... define requirements for the measurement of operational infrastructures i.e. taking into account the
real operating conditions over a defined period of time

GLOBAL KPI’S

Objective KPIs... may be combined using a formula appropriate to the specific operational
infrastructure to produce one or more Global operational KPIs which reflects the overall performance
of the operational infrastructures against wider energy management targets
...which may be self-imposed by the operators or externally applied by legislators

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Operation Standards - CENELEC

The EN 50600 series


EN 50600-3-x Operational standards
-
European
Data Centre
Standardisation Information technology - Data centre facilities and infrastructures

EN 50600-3-1:2016 Management and operational information

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre RM Standards - CENELEC

The EN 50600 series


EN 50600-4-x Information Technology - Data Centres
-
European
Data Centre
EN 50600-4-1:2016 Overview of and general requirements for key performance indicators
Standardisation
EN 50600-4-2:2016 Power Usage Effectiveness (PUE)

EN 50600-4-3:2016 Renewal Energy Factor (REF)

Influenced by design and operation of data centres


-
AND linked to European standards for design and operation

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
CLC TR 50600-99-1
CEN CENELEC (CLC) ETSI
The EN 50600 series
European Committee European Committee European
- for Standardization for Electrotechnical Telecommunications
European Standardization Standardis Insitute
Data Centre
Standardisation
CEN-CENELEC-ETSI
CO-ORDINATION GROUP
GREEN DATA CENTRES

STATUS REPORT
An in-depth mapping of the
standardisation demands of
energy efficient and sustainable
data centres
BROCHURE
Primary objectives:
A “laymans” guide to
• provide basic definitions
the standardisation
• differentiate types of deliverable
• product, design, operation actions to support the
• define topic boundaries delivery of energy
• map existing deliverables efficient and sustainable
• identify opportunities data centres
• minimise duplication
• within ESOs and ISO/IEC

Updated Q3 2015 Updated Q3 2015


Layer One
Greece
ftp://ftp.cencenelec.eu/EN/EuropeanStandardization/HotTopics/ICT/GreenDataCentres/GDC_report.pdf

9th October 2015


ftp://ftp.cencenelec.eu/EN/EuropeanStandardization/HotTopics/ICT/GreenDataCentres/GDC_report_summary.pdf

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
CLC/TR 50600-99-1

The EN 50600 series


Code of Conduct for Data Centre Energy Efficiency
-
European
Data Centre
Standardisation

A “scheme” to monitor energy


efficiency activity

“Best Practices” V6.1.1 (annual update)

Information technology - Data centre facilities and infrastructures


Layer One
Greece
CLC/TR
Energy management - Recommended practices
50600-99-1:2016
9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
The Complete Package

The EN 50600 series


-
EN 50600-2-X
European
Data Centre
Standardisation
EN 50600-2-1
EN 50600-2-2 EN 50600-3-1
EN 50600-2-3

DESIGN OPERATION

CLC/TR 50600-99-1

ASSESSMENT

EN 50600-4-2 EN 50600-4-X
Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Close

The EN 50600 series


-
European
Data Centre
Standardisation

The EN 50600 series


-
European data centre standardisation

Mike Gilmore, e-Ready Building Limited

Layer One
Greece

9th October 2015

www.it-cabling.com www.e-readybuilding.com
© 2015 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721