Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ADMAG AE Series (Fieldbus communication type) - Yokogawa


Category Sitemap GLOBAL
Home / Our Businesses / IA / Products / Field Instruments / Flow / ADMAG AE Series /

ADMAG AE Series (Fieldbus communication type)


The ADMAG AE is our Advanced Engineering magnetic flowmeter. An evolution of the About Us
field-proven ADMAG series, the ADMAG AE employs the dual frequency excitation Worldwide Locations
method to provide quick response and noise free output, and has a ceramic lining that
Powered by Ultraseek
supports an even greater range of applications.

Search
Product Information
Industrial
ADMAG AE series Automation and
Control Business

Field Instruments
ADMAG AE(Fieldbus communication type) is a
compact type magnetic flowmeter that is the Pressure
successor of the ADMAG AM and continues to use Flow
the dual frequency excitation method. ADMAG AE Series
Ex-proof-type, both of integral and remote type, can · ADMAG AE Series
be provided. (Fieldbus
communication
Specifications (Fieldbus Communication) type)
Temperature
Level
Valve Positioners &
Converters
Fieldbus
Auxiliary Instruments
New Products
Features Download
Contact Us
● Eliminates the drawbacks of the conventional pulsed DC excitation method. Index
The dual frequency excitation method provides stable measurement in fluid flow with
high-density slurry and low conductivity fluid flow, as well as a quick response and
high zero stability.
● Superior abrasion and corrosion resistance for measurement for high-temperature
application
Yokogawa's ceramic flow tube is 99.9% high purity alumina to deliver maximum
reliability.
● For batch control and pulsating flow measurement
Quick response of 0.1 sec allows accurate measurement in batch controlled and
pulsating flows.
● Highly reliable leak-free electrode construction
The electrodes are trouble-free due to no clearance between the molded PFA lining and
springs.
The electrodes for the ceramic lining are also leak-free because there is no seal point
between the electrode and ceramic flow tube thanks to the use of a unique liner molding
technology.

file:///H|/DATA/YOKAGAWA%20ADMAG%20AE.htm (1 of 4)5/10/2005 10:29:26 AM


ADMAG AE Series (Fieldbus communication type) - Yokogawa

● Dual cavity housing converter for greater environmental resistance


Separation of electronic parts from wiring parts to protect them from water infiltrating
into the wiring port.
● Explosion-proof, integral type and remote type
An explosion-proof type with built-in barrier is available.

Specifications

AE Integral magnetic flowmeter(Fieldbus communication type)


AE100 AE200 AE300
Size (mm) 2.5-10 15 25-200 250-400
Excitation Dual frequency
Flow span (m/s) 0.3-10
Min. fluid conductivity (µS/cm) 20 5
Protection IP67, NEMA4X, JIS C0920 watertight type
Hazardous area classification ATEX/FM/TIIS(JIS) ATEX
Accuracy ±0.5% of flowrate
Repeatability ±0.1% of flowrate (1 mm/s min.)
Ceramic -----
Lining material Fluorocarbon PFA
----- Polyurethane
Pt-Al2O3 cermet
Ceramic -----

Electrode material SUS316L, Pt-Ir, HastelloyC-276 equivalent , Tantalum,


PFA
Titanium
Polyurethane ----- SUS316L
-0.1 MPa to 4 MPa: Ceramic lining size 50 mm or smaller
Fluid pressure
-0.1 MPa to 2 MPa: Others
-10 deg C to 120 deg C: Ceramic lining, Fluorocarbon PFA
Fluid temperature lining
-10 deg C to 40 deg C: Polyurethane lining
JIS 10K/20K/F12, ANSI 150/300, DIN PN10/16: Wafer,
Process connection*
flange, union joint, ISO clamp
Digital communication signal based on FOUNDATION™
Output signal
Fieldbus protocol
Bi-direction flow measurement, variable damping time
Function (0.1 sec min.), alarm output at high/low limit, self-
diagnostics, empty pipe detection, loop test
Indicator 7-seg. LCD with back light
Power supply voltage 80-264 V AC or 100-130 V DC
Maximum power consumption 12.5 W
*: Depends on the size and lining material.

AE Flow Tube(Fieldbus communication type)

file:///H|/DATA/YOKAGAWA%20ADMAG%20AE.htm (2 of 4)5/10/2005 10:29:26 AM


ADMAG AE Series (Fieldbus communication type) - Yokogawa

AE100 AE200 AE300


Size (mm) 2.5/5/10 15 25 to 200 250 to 400
Excitation Dual Frequency
Flow Span (m/s) 0.3 to 10
Min. fluid conductivity (µS/cm) 20 5
Protection IP67, NEMA4X, JIS C0920 Water Tight Type
Hazardous Area Classification ATEX/FM/TIIS(JIS) ATEX
Accuracy 0.5 % of flowrate
Repeatability 0.1% of flowrate (min. 1mm/s)
Ceramic -----
Lining Material Fluorocarbon PFA
----- Polyurethane
Electrode Material -----
Ceramic Lining Platinum-alumina cermet -----
SUS316L, HastelloyC-276 equivalent, Titanium, Tantalum,
Fluorocarbon PFA Lining
Pt-Ir
Polyurethane Lining ----- SUS316L
-0.1 to 4MPa : Ceramic Lining Size 50mm or smaller
Fluid Press.
-0.1 to 2MPa : Other type
-10 to 180 deg C : Ceramic Lining / -10 to 160 deg C :
Fluid Temp. Fluorocarbon PFA Lining /
-10 to 40 deg C : Polyurethane Lining
DIN PN10/16, ANSI150/300, JIS10K/20K/F12 :
Process Connection
Wafer, Flange, Union joint or IDF clamp

AE14 Flow Converter(Fieldbus communication type)


Digital communication signal lased on FOUNDATION
Output Signal
fieldbus protocol
Communication FOUNDATION™ fieldbus
Bi-direction flow measurement, variable damping time (0.1
Function sec min.), alarm output at high/low limit, self-diagnostics,
empty pipe detection, loop test
Indicator 7 seg.LCD with back light
Protection IP67, NEMA4X, JIS C0920 Water Tight Type
Hazardous Area Classification ATEX, FM, TIIS(JIS)
Power Supply Voltage 80 to 264V AC or 100 to 130V DC
Maximum Power Consumption 12.5W
Mounting 2-inch pipe mounting

(Note) AE Series of SAA Ex-proof type is available besides the above stated Fieldbus
communication type.

file:///H|/DATA/YOKAGAWA%20ADMAG%20AE.htm (3 of 4)5/10/2005 10:29:26 AM


ADMAG AE Series (Fieldbus communication type) - Yokogawa

Viewing PDF files requires Adobe Acrobat Reader.

Top of this page

Terms of Use Privacy Guidelines

file:///H|/DATA/YOKAGAWA%20ADMAG%20AE.htm (4 of 4)5/10/2005 10:29:26 AM

You might also like