KLR COLLEGE OF ENGINNERING & TECHNOLOGY

BCM ROAD, PALONCHA-507115, KHAMMAM DIST


IV B.TECH I-SEM MID-I EXAMINATION
Branch: EEE (B.Tech) Regulation: R18 Date: 09-11-2021 F.N
Subject: EHV Time: 09.40AM to 10.40A.M

PART-A
2X2=4M
1. Explain the vehicle power source characterization
2. Explain the power flow control in series hybrid vehicles
3. Explain the social and environmental importance of hybrid and electric vehicles
PART-B
2x3=6M
4. Explain the impact of modern drive trains on energy supplies
5. Explain mechanical translation system
6. Explain the standard test signals that are used in the time domain analysis

KLR COLLEGE OF ENGINNERING & TECHNOLOGY


BCM ROAD, PALONCHA-507115, KHAMMAM DIST
IV B.TECH I-SEM I-MID EXAMINATION
Branch: EEE (B.Tech) Regulation: R18 Date: 09-11-2021 F.N
Subject: EHV Time: 09.40AM to 10.40A.M

PART-A
2*2=4M
1. Explain the vehicle power source characterization
2. Explain the power flow control in series hybrid vehicles
3. Explain the social and environmental importance of hybrid and electric vehicles

PART-B 2*3=6
2

1. Explain the impact of modern drive trains on energy supplies


2. Explain mechanical translation system
3. Explain the standard test signals that are used in the time domain analysis
2x3=6M

KLR COLLEGE OF ENGINNERING & TECHNOLOGY


BCM ROAD, PALONCHA-507115, KHAMMAM DIST
II B.TECH II-SEM II-MID EXAMINATION
Branch: EEE (B.Tech) Regulation: R16 Date: -10-2020 F.N
Subject: SGP(SWITCHGEAR AND PROTECTION) Time: 11.30AM to 1.00PM
NAME:………………………. H.T No.:…………………..

1. Which of the following grounding methods is used to reduce the tower footing resistance where an
earth resistance is low? ( )
A. single driven rod
B. multiple rods
C. counter poises
D. plates
2. Impulse ratios of insulators and lightning arresters should be ( )
A. both low
B. high and low
C. low and high
D. both high
3. To protect the power transformer (Y-Y with neutral grounded) against fault what type of connection
do the CTS have? ( )
A. delta – star
B. delta-delta
C. star – star
D. star-delta
4. Which is the main relay for protecting up to 90% of the transmission line length in the forward
direction? ( )
A. directional over current relay
B. mho relay
C. carrier current relay
D. impedance relay
5. The rating of lightning arrester used for 220KV, 3 phase system is ( )
A. 220KV,10KA
B. 220KV,5KA
C. 198KV,10KA
D. 198KV,2KA
6. Severe over voltages are produced during arcing faults in a power system with the neutral ( )
A. isolated
B. solidly earthed
C. earthed through a low resistance
D. earthed through an inductive coil
7. In the protection of transformers, harmonic restraint is used to guard against ( )
A. magnetizing inrush current
B. unbalanced operation
C. lightning
D. switch over voltages
8. The various protection schemes as applied to feeder protection ( )
A. time graded protection
B. distance protection
C. carrier current protection
D. All the above
9. Which of the following is true with respect to valve type lightning arrester? ( )
A. also known as non linear arresters
B. consist of a stack of spark gaps and resistor discs
C. ohmic value decreases as current increases
D. All the above
10. The common transformer faults are ( )
A. open circuits
B. over heating
C. winding short circuits
D. All the above

11. The method of grounding by insertion of a reactance is called as __________ grounding.

12.In resonant grounding, the function of the ______________ coil is to make arcing earth faults self
extinguishing.

13. The valve type arresters can be classified as ___________ and __________types.

14. In a transformer ____________ relays protect against phase to phase faults and overloading

15. The ideal scheme of protection for lines is ________________.

16. The two most commonly used schemes for bus bar protection are ______________ and
________________.

17 A _________________ connected to the line and earth in power system protects the terminal
equipment
against travelling surges.

18. A ________________ relay is used for protection of a transformer against all internal faults

19. _______________ grounding is normally employed on systems operating at voltages between 2KV
and 33KV.

20. Bus bar zone, for the protection includes _____________________________.