Professional Documents
Culture Documents
Measurement Report: Instrument Configuration
Measurement Report: Instrument Configuration
Measurement Report: Instrument Configuration
Instrument configuration
Measurement start 11/11/2020 14:00:00
Measurement stop 11/11/2020 14:06:20
Unit type SVAN 977
Unit S/N 45712
Software version 1.26
Integration period Infinity
Logger step 5s
Leq/RMS integration Linear
Pre Calibration type By measurement
Pre Calibration date time 11/11/2020 13:59:20
Pre Calibration factor 1.57 dB
Post Calibration type By measurement
Post Calibration date time 11/11/2020 14:09:54
Post Calibration factor 1.38 dB
Logger results
dB dB
90.0 90.0
Acoustic pressure
Acoustic pressure
85.0 85.0
80.0 80.0
75.0 75.0
70.0 70.0
14:00:00 14:00:30 14:01:00 14:01:30 14:02:00 14:02:30 14:03:00 14:03:30 14:04:00 14:04:30 14:05:00 14:05:30 Time
14:00:05
Start Duration LApeak (TH) [dB] LAFmax (TH) [dB] LAFmin (TH) [dB] LAeq (TH) [dB]
Info - - P1 (A) P1 (A, Fast) P1 (A, Fast) P1 (A, Lin)
Main cursor 11/11/2020 14:00:05 - 83.0 72.4 69.7 70.5
www.svantek.com 1
Logger 1/3 Octave
dB dB
80.0 80.0
Acoustic pressure
Acoustic pressure
70.0 70.0
60.0 60.0
50.0 50.0
40.0 40.0
30.0 30.0
Total results
No. 1
Start date & time 11/11/2020 14:00:00
Duration 00:06:20.000
Elapsed time 06:20
P1 (A, Lin) LAeq (SR) [dB] 70.7
P2 (C, Lin) LCeq (SR) [dB] 77.0
P3 (Z, Lin) LZeq (SR) [dB] 78.5
RAFAEL Assinado de
forma digital por
CARLOS RAFAEL CARLOS
CORREA: CORREA:374954
01877
3749540 Dados:
2020.11.16
1877 09:17:28 -03'00'
www.svantek.com 2