Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

Technical data sheets

Leonova™ Infinity – Platform

LEO801 15310
LEO802

14715 CAS16

LeonovaTM Infinity is a hand-held machine condition ana- Parts of the Leonova Infinity system are specified on the
lyser with colour touch screen, operating under Windows technical data sheets (TD) listed below:
CE. Following functions are always included for unlimited
use: Instrument specifications TD-211
• Data logging with Condmaster®Nova Selection of instrument functions TD-212
• ISO 2372 vibration monitoring SPM Shock pulse measurement, dBm/dBc TD-213
• Speed measurement SPM Shock pulse measurement, LR/HR TD-214
• Temperature measurement SPM Spectrum TM
TD-218
• Analog signals, current and voltage ISO 2372 vibration monitoring TD-225
• Reading from and writing to CondID® memory tags ISO 10816 vibration monitoring with spectrum TD-219
• Manual recording, free quantity FFT with symptoms TD-220
• Check points, free text EVAM Evaluated vibration analysis
®
TD-221
The main Leonova functions are user selected, see TD-212. 2 channel simultaneous vibration monitoring TD-222
With synchronous measurement, enveloping, true zoom Run up/Coast down and Bump test TD-223
and up to a 12 800 line spectrum over 0.5 Hz up to 40 kHz, Orbit analysis TD-224
LeonovaTM Infinity has full vibration analysis capacity. SPM Balancing TD-226
has also incorporated the evaluation tables of the new ISO
Shaft alignment TD-227
10816 standards for broad-band measurement of vibration
Long-time recording TD-228
velocity, acceleration and displacement. For single and
Order tracking TD-306
dual plane rotor balancing, an easy to use graphical guide
calculates balancing weights and their position. For shaft Services TD-229
alignment, Leonova Infinity uses advanced laser technique Protective cover TD-246
with easy targeting, modulated line laser beam and auto- Transducers and measuring cables TD-247
matic precision calculation of shaft positions. LineLazerII detector units TD-267

Ordering numbers Spare parts


LEO801 Leonova Infinity, Grey, incl. wrist strap and stylus 15178 Stylus for touch screen
LEO802 Leonova Infinity, Blue, incl. wrist strap and stylus 14661 Wrist strap
90362 Charger 9.3 V/1.33 A, 100-240 V AC, Euro-plug PRO49 Leonova Service Program
90379 Charger 9.3 V/1.33 A, 100-240 V AC, US-plug 71789 Instruction "Getting started"
90380 Charger 9.3 V/1.33 A, 100-240 V AC, UK-plug 71792 Leonova Infinity User guide
CAB46 Communication cable, USB
CAB47 Communication cable RS232, 9 pin
14715 Belt clip
15310 Protective cover Patent No.: US7313484, US7167814, US7200519, US7054761, US7324919
CAS16 Carrying case, plastic with foam insert EPO1474664, DE60304328.3, FR1474664, GB1474664, NL1474664, SE03731865.6

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2009-02. TD-210 B
Leonova™ Infinity – Instrument Specifications

102

63
285

32
63

Leonova Infinity is a multi-function, hand-held data logger. of the measuring functions listed below (Platform). Other
The instrument is operated via keypad and touchscreen. diagnostic and analytic functions, for shock pulse measure-
Basic data for the measurement set-up can be input manu- ment, vibration measurement, orbit analysis, rotor balanc-
ally or downloaded from Condmaster®Nova.  ing and shaft alignment, are user selected. For technical
Leonova Infinity is always programmed for an unlimited use information and specifications, see respective data sheets
listed on TD-212.

Technical data, instrument (Platform) Vibration severity (ISO 2372)


Housing: ABS/PC, Santoprene, IP54 Measurement quantity: vibration velocity, RMS,
Dimensions: 285 x 102 x 63 mm range 10 – 1000 Hz
Evaluation table selection: menu guided, ISO 2372
(11.2" x 4" x 2.5")
Vibration transducer input: < 18 Vpp. Transducer supply of
Weight: 580 g (20 oz.) 4 mA for IEPE* (ICP) type can be
Keypad: sealed, snap action set On/Off
Display: touch screen, TFT colour, Transducer types: Any transducers (disp., vel. or acc.)
240 x 320 pixels, 54 x 72 mm with voltage output
(2.1 x 2.8 inch), adjustable Vibration channels: 2, simultaneous measuring
backlight
Main processor: 400 MHz Intel® XScale® Speed measurement
Memory: 64 MB RAM, 32 MB Flash Measuring range: 10 to 60 000 rpm
expandable up to 4 GB Resolution: 1 rpm
Operating system: Microsoft Windows® CE.net Accuracy: ± (1 rev. + 0.1% of reading)
Communication: RS232 and USB Transducer type: TAD-18, TTL-pulses
Dynamic range: 16 bit A/D converter, automatic
gain settings Temperature measurement
Condition indication: green, yellow and red LEDs Measuring range: –50 to +440 °C (–58 to 824 °F)
Resolution: 1 °C (1 °F)
Power supply: rechargeable Lithium-Ion batteries
Transducer type: TEM-11 with TEN-10 (surface tem-
Battery power: for minimum 8 hours normal use
perature) and TEN-11 (liquids)
Operating temperature: 0 to 50 °C (32 to 120 °F)
Charging temperature: 0 to 45 °C (32 to 113 °F) Analog signals
General features: language selection, battery charge Measurement range: 0 to 1 V DC, 0 to 10 V DC,
display, transducer line test, metric 0 to 20 mA, 4 to 20 mA
or imperial units
* Integral Electronic PiezoElectric
Meas. point identification: RF transponder for communication
with CondIDTM tags, read/write Patent No.: US7313484, US7167814, US7200519, US7054761, US7324919
distance max. 50 mm (2 inch) EPO1474664, DE60304328.3, FR1474664, GB1474664, NL1474664, SE03731865.6

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2008-08. TD-211B.
Leonova™ Infinity – User selected functions

LR/HR dBm/dBc
Balancing Leonova™ Infinity Platform,
SPM single plain
Spectrum always included for unlimited use
ISO Balancing • Data logging with Condmaster®Nova
10816 dual plain
• RMS vibration, ISO 2372
FFT with Shaft • Speed measurement
symptoms alignment
• Temperature measurement
PLATFORM
12800 lines • Analog signals, current and voltage
EVAM
40 kHz
• Reading from and writing to CondID®
Run up/ memory tags
coast down Recording
Bump test
• Manual recording, free quantity
2 channel Extended • Check points, free text
vibration memory
Orbit Time
analysis Order signal
tracking

To obtain the optimal performance range and instrument Leonova automatically deducts credits from the tank when
price for their purpose, Leonova users can select any or all its 'Measure' key is pressed. Thus, the user's operating costs
of the 16 condition diagnosis and maintenance functions depend on the number of measurements taken. Credit tanks
below, under two alternative conditions of sale. The choice are refilled, and/or new functions added, by loading a coded
is between unlimited and limited use (Function & Use). file ordered via the local distributor.

When use is limited, the price for the function itself is much Free and limited functions can be combined at will. Platform
lower. Instead, the user prepays a tankful of 'credits'. functions are always included and their use is unlimited.

Functions for Unlimited Use Functions for Limited Use (Function & Use)
LEO130 Shock pulse method dBm/dBc LEO230 Shock pulse method dBm/dBc (1)
LEO131 Shock pulse method LR/HR LEO231 Shock pulse method LR/HR (2)
LEO132 SPM Spectrum LEO232 SPM Spectrum (2)
LEO133 ISO 10816 vibration monitoring with spectrum LEO233 ISO 10816 vibration monitoring with spectrum (1)
LEO134 FFT with symptoms LEO234 FFT with symptoms (2)
LEO135 EVAM evaluated vibration analysis, time signal LEO235 EVAM evaluated vibration analysis, time signal (2)
LEO136 2 channel simultaneous vibration monitoring LEO236 2 channel simultaneous vibration monitoring (4)
LEO137 Run up / coast down & bump test LEO237 Run up / coast down (50) and Bump test (25)
LEO138 Orbit analysis LEO238 Orbit analysis (5)
LEO151 Shock pulse method dBm/dBc and LR/HR LEO251 Shock pulse method dBm/dBc and LR/HR
LEO152 Balancing, single plane LEO252 Balancing, single plane (4 runs 16, 2 runs 42)
LEO153 Balancing, dual plane LEO253 Balancing, dual plane (80)
LEO154 Balancing, single and dual plane LEO254 Balancing, single and dual plane
LEO155 Shaft alignment LEO255 Shaft alignment (30)

Credit consumption is stated within brackets.


Options and additional functions
LEO139 12 800 lines / 40 kHz, option to FFT with
symptoms and EVAM
LEO160 Recording function
LEO161 Extended memory, 512 MB
LEO162 Extended memory, 1 GB
LEO163 Extended memory, 4 GB
LEO164 Time signal, option to FFT with symptoms
LEO165 Order tracking, option to FFT with symptoms
and EVAM

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2009-02. TD-212B.
Leonova™ Infinity – Shock pulse measurement, dBm/dBc

Normalized condition scale

delta

Input: Rpm plus shaft diameter


(or ISO bearing number)

For over 30 years, the original Shock Pulse Method (SPM) Shock pulse amplitude is due to three basic factors:
has been very successfully used to obtain a fast, easy and • Rolling velocity (bearing size and rpm)
reliable diagnosis of the operating condition of rolling ele- • Oil film thickness (separation between the metal sur-
ment bearings. faces in the rolling interface). The oil film depends on
lubricant supply and also on alignment and pre-load.
The signal • The mechanical state of the bearing surfaces (rough-
Throughout their lifetime, bearings generate shocks in the ness, stress, damage, loose metal particle).
interface between the loaded rolling element and the race-
way. These shocks 'ring' the SPM transducer which outputs Input data
electric pulses proportional to the shock magnitude. The effect of rolling velocity on the signal is neutralized by
giving rpm and shaft diameter as input data, with 'reason-
Unlike vibration transducers, the shock pulse transducer able accuracy'. This sets an initial value (dBi), the start of
responds at its carefully tuned resonance frequency of about the ´normalized' condition scale.
32 kHz, which allows a calibrated measurement of the shock
pulse amplitudes. Evaluation
The initial value and the range of the three condition zones
Measurement (green - yellow - red) was empirically established by testing
The shock pulse meter counts the rate of occurrence (in- bearings under variable operating conditions. The maximum
coming shock pulses per second) and varies the measuring value places the bearing into the condition zone. The height
threshold until two amplitude levels are determined: of the carpet value and delta (dBm minus dBc) indicated
lubrication quality or problems with bearing installation
• the shock carpet level (approx. 200 incoming shocks and alignment.
per second. This level is displayed as dBc (decibel car-
pet value). Technical data
• the maximum level (highest incoming shock under 2 Measuring range: –9 to 99 dBsv
seconds). This level is displayed as dBm (decibel maxi- Resolution: 1 dBsv
mum value). Using a blinking indicator or earphones, Accuracy: ± 1 dBsv
the operator can establish a peak value by increasing Transducer types: SPM 40000/42000, probe transducer and
the measuring threshold until no signal is registered. quick connector transducer for adapters
Input data: Rpm, shaft diameter (or ISO bearing number)
Because of the very large dynamic range, shock pulses are Output: Maximum value dBm, evaluated green -
measured on a decibel scale (1000 x increase between 0 yellow -red, carpet value dBc, peak value,
and 60 dB). audible shock pulse signal (earphones).

Ordering numbers
LEO130 Shock pulse method dBm/dBc, unlimited use
LEO230 Shock pulse method dBm/dBc, limited use

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-213 B
Leonova™ Infinity – Shock pulse measurement, LR/HR

Evaluation boxes determined by


bearing geometry and speed
Calibration

The LR/HR method was developed from the original Shock A LUB no. of 0 means dry running, the value increases with
Pulse Method for condition diagnosis of rolling element oil film thickness. A COND no. of around 30 indicates surface
bearings. It allows a precision analysis of oil film condition stress or early damage, the value increases with damage
in the rolling interface and contains calculation models for severity. The general assessment is:
finding the optimal lubricant. Poor lubrication is the root CODE A Good bearing
cause of most bearing failures. CODE B Poor lubrication
CODE C Dry bearing, risk of damage
Signal and measurement CODE D Damage.
Transducer and measuring procedure are the same as for
A program part, LUBMASTER, uses the shock values plus
the dBm/dBc method (TD-213). The shock pulse meter
data on lubricant type, viscosity, load and operating tem-
counts the rate of occurrence (incoming shock pulses per
perature to calculate the bearing's life expectancy under
second) and varies the gain until two amplitude levels are
present condition. It also calculates the effect of changes
determined:
in oil type and viscosity.
• HR = high rate of occurrence, quantifying the shock
carpet (approx. 1000 incoming shocks per second). Calibration
• LR = low rate of occurrence, quantifying the strong The accuracy of the LR/HR method is increased by a calibra-
shock pulses (approx. 40 incoming shocks per second). tion factor (COMP no.) used in case of bearings with minimal
load or poor quality measuring points (in both cases the
LR and HR are 'raw values', measured in dBsv (decibel
signal strength is below normal). On the basis of the bear-
shock value).
ing's catalogue data and the lubricant properties, Leonova
calculates the normal shock level for a good bearing and
Input data
compensates for an abnormally low signal before returning
The LR/HR method requires more precise data on the the evaluation results.
bearing, because bearing geometry, as well as size and
speed, affect the shock carpet and thus the analysis of oil Technical data
film condition in undamaged bearings. The rpm is needed, Measuring range: –19 to 99 dBsv
plus a definition of the bearing type and size. This is best Resolution: 1 dBsv
input by stating the ISO bearing number, which links to the Accuracy: ± 1 dBsv
bearing catalogue in Condmaster.
Transducer types: SPM 40000/42000, probe transducer and
quick connector transducer for adapters
Evaluation
Input data: Rpm, plus bearing type and mean diameter
After measurement Leonova returns (or ISO bearing number)
• a general description of bearing condition (CODE) Output: LR and HR (raw shock values),
• a value for oil film condition (LUB) CODE A to D, evaluated green - yellow - red.
LUB no. for oil film condition,
• a value for surface damage (COND). COND no. for surface condition.

Ordering numbers
LEO131 Shock pulse method LR/HR, unlimited use
LEO231 Shock pulse method LR/HR, limited use

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-214 B
Leonova™ Infinity – SPM Spectrum

Damage
severity

Trend

Pattern recognition:
Bearing with rotating inner race and a damaged outer race.
BPFO = ball pass frequency outer race and its multiples domi-
nate the shock pulse spectrum.

The purpose of 'SPM Spectrum' is to verify the source of measured, not preset. The factors defining the bearing
high shock pulse readings. Shocks generated by damaged frequencies are obtained from the bearing catalogue in
bearings will typically have an occurrence pattern matching Condmaster by stating the ISO bearing number.
the ball pass frequency over the rotating race. Shocks from
e. g. damaged gears have different patterns, while random Evaluation
shocks from disturbance sources have none. The frequency patterns of bearings are preset in Cond­
master. Linking the symptom group 'Bearing' to the measur-
Signal and measurement ing point allows the user to highlight a bearing pattern by
The resonance frequency of the SPM shock pulse trans- clicking on its name. Other symptoms can be added when
ducer, calibrated to 32 kHz, constitutes the ideal carrier appropriate, e. g. for gear mesh patterns. Finding a clear
wave for transients caused by shocks. The output of this match of a bearing symptom in the spectrum is proof that
transducer is the same type of demodulated signal pro- the measured signal originates from the bearing.
duced by 'enveloping', with this important difference: both
frequency and amplitude response of the SPM transducer Technical data
are precisely tuned, so there is no need to find uncertain Frequency range: 0 to 100, 200, 500, 1000, 2000,
and shifting machine resonances to get a signal. 5000, 10 000, 20 000 Hz

Leonova first measures the shock amplitude by a shock Number of spectrum lines: 400, 800, 1600, 3200, 6400
pulse measurement with the dBm/dBc or the LR/HR meth- Measurement windows: Rectangle, Hanning, Hamming,
Flat Top
od. The results are the bearing condition data, evaluated
Spectrum types displayed: linear, power
green - yellow - red.
Averages: time synchronous, FFT linear, FFT
The second measurement produces a time record that is peak-hold
subjected to a Fast Fourier Transform (FFT). The resulting Frequency units: Hz, CPM
spectrum is used mostly for pattern recognition. Spectrum Saving options for spectrum: full spectrum, peaks only
line amplitudes are influenced by too many factors to be Amplitude scale unit: SD (Shock Distribution), SL (Shock
reliable condition indicators, so all condition evaluation is Level)
based on the dBm or the HR values. Scaling: linear or logarithmic X and Y axis

One unit for amplitude in an SPM spectrum is SD (Shock Zoom: true FFT zoom, visual zoom
Distribution unit), where each spectrum is scaled so that Pattern recognition: Bearing frequencies and optional
patterns highlighted in the spec-
the total RMS value of all spectrum lines = 100 SD = the trum. Automatic configuration of
RMS value of the time record. The alternative is SL (Shock bearing symptoms linked to ISO
Level unit), the RMS value of the frequency component in bearing no.
decibel. Alarm levels are manually set for each symptom to Transducer type: Shock pulse transducers with
show evaluated results in green - yellow - red. Various types probe and quick connector, SPM
40000/42000
of spectra can be produced. The recommended setting is
a spectrum with a resolution of at least 0.25 Hz, e. g. 3200 As an option, the frequency range can be extended to 40000 Hz,
the number of spectrum lines to 12800.
lines over 500 Hz, saving peaks only.
Ordering numbers
Input data
LEO132 SPM Spectrum, unlimited use
Pattern recognition demands precise data on the bearing
LEO232 SPM Spectrum, limited use
and exact measurement of the rpm. The rpm should be
LEO139 12 800 lines, 40 kHz, option

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-09. TD-218 B
Leonova™ Infinity – Vibration ISO 2372

Broad band vibration measurement is the most widely • Measurements are made in three direction (horizontal,
used and cost-efficient method for the diagnosis of general vertical, axial). The highest value returned determines
machine condition. There are two ISO recommendations machine condition.
concerning this type of machine condition monitoring, the • Default limit values for the change from green to
much used ISO 2372 and the more recent ISO 10816, which yellow and from yellow to red are set automatically
is a ongoing replacement of the older standard. when one of the six machine classes is input under the
measuring point data.
In Leonova, vibration measurement according to ISO 2372
is a platform function, always included for unlimited use. ISO 10816 is offered as a choice, see TD 219.

The features are:


Technical data
• Machine condition is diagnosed on the basis of broad
Measurement quantities: Velocity, RMS value in mm/s over
band measurements returning an RMS value of vibra- 10 to 1000 Hz
tion velocity in the frequency range of 10 to 1000 Hz. Transducer type: Vibration transducer SLD144 or IEPE*
This is called vibration severity. (ICP®) type transducers with voltage
output
• Machines are grouped into six vibration classes.
* Integral Electronic PiezoElectric
• A table of limit values is presented for each vibration
class, differentiating between acceptable vibration
(green range), unsatisfactory vibration (yellow range),
and vibration that will cause damage unless reduced
(red range).

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-11. TD-225 B
Leonova™ Infinity – Vibration ISO 10816 with spectrum

Broad band vibration measurement is the most widely • The standard consists of several parts, each treating
used and cost-efficient method for the diagnosis of general a certain type of machines, with tables of limit values
machine condition. differentiating between acceptable vibration (green
range), unsatisfactory vibration (yellow range), and
There are two ISO recommendations concerning machine vibration that will cause damage unless reduced (red
condition monitoring by this type of measurement, the much range).
used ISO 2372 and the more recent ISO 10816, which is an
ongoing replacement of the older standard. In Leonova, ISO part, machine group and foundation type
are input using a multiple choice guide which displays the
With Leonova, ISO 2372 measurement is a platform func- various ISO definitions and leads to the limit values.
tion, always included for unlimited use (see TD-225).
ISO 10816 is an option with ordering numbers LEO133 Exceeding the requirements of the ISO standard, Leonova
(unlimited use) and LEO233 (limited use). also provides a 1600 line spectrum.

Features of ISO 10816 are:


Technical data
• Measurements are made in three direction (horizontal,
Measurement quantities: Velocity, acceleration, and displace
vertical, axial). ment, RMS values over 2 or 10 Hz to
• Machine condition is generally diagnosed on the basis 1000 Hz, peak, peak - to-peak
of broad band vibration measurements returning an Spectrum: Linear, 1600 lines, Hanning window.
RMS value. ISO 10816 keeps the lower frequency Spectrum unit: Velocity, mm/s or inch/s
range flexible between 2 and 10 Hz, depending on the
Transducer type: Vibration transducer SLD 144 or IEPE*
machine type. The upper frequency is 1000 Hz.
(ICP®) type transducers with voltage
• ISO 10816 operates with the term vibration magni- output
tude, which, depending on the machine type, can be
* Integral Electronic PiezoElectric
an RMS value of vibration velocity, acceleration or
displacement. If two or more of these parameters are
measured, vibration severity is the one returning the Ordering numbers
relative highest RMS value. For certain machines, ISO LEO133 Vibration ISO 10816 with spectrum, unlimited use
10816 also recognises peak-to-peak values as condi- LEO233 Vibration ISO 10816 with spectrum, limited use
tion criteria.

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-219 B
Leonova™ Infinity – FFT spectrum with symptoms

FFT Spectrum with Symptoms is a vibration analysis function Spectrum analysis with 'symptoms'
offered with Leonova, for either limited or unlimited use. For easy pattern recognition in spectra, a range of ready
It is a reduced form of EVAM (Evaluated Vibration Analysis made 'fault symptoms' are downloaded from Condmaster.
Method), lacking the function true zoom, the statistical These are instructions to highlight a spectrum line pattern
evaluation by means of criteria and possibility to display and display the sum of the lines' RMS values as a symptom
and save time signal (option). parameter (which can be trended).
This function generates three sets of machine condition Most symptoms are automatically configured by using the
data: rpm as a variable, for some an input is needed, e. g. the
• Condition parameters, which are measured and cal- number of vanes on a rotor.
culated values describing various aspects of machine
A special symptom group are the bearing symptoms (show-
vibration.
ing e. g. ball pass frequencies over inner and outer race)
• Vibration spectra where significant line patterns are
for which the Condmaster bearing catalogue contains all
found, highlighted and evaluated with the help of pre-
need data.
set fault symptoms.
• Trending of symptom values. Alarm levels are manually Suitable symptoms and symptom groups are selected from a
set for evaluation in green- yellow - red. menu in Condmaster when the measuring point is set up.

For each measuring point, the user can make an individual


Technical data
selection and define the type of data best suited for the
Frequency limit, lower: 0.5, 2, 10 or 100 Hz
surveillance of an individual machine. Frequency limit, upper: 100, 200, 500, 1000, 2000, 5000,
10 000 Hz
Condition parameters Envelope high pass filters: 100, 200, 500, 1000, 2000, 5000,
10 000 Hz
Condition parameters are measured for a selected frequen-
Measurement windows: Rectangle, Hanning, Hamming, Flat Top
cy range. They can be individually activated and are shown
Averages: time synch, FFT linear,
in measuring result tables and as diagrams. Available are: FFT exponential, FFT peak-hold
VEL RMS value of vibration velocity Spectrum lines: 400, 800, 1600, 3200, 6400
Frequency units: Hz, CPM, orders
ACC RMS value of vibration acceleration
Saving options: peaks only, full spectrum
DISP RMS value of vibration displacement Spectrum types displayed: linear, power, PSD
CREST Crest value, difference between peak and RMS Zoom: visual zoom
Transducer types: vibration transducer SLD144 or IEPE
KURT Kurtosis, the amount of transients in the vibration (ICP®) type transducers with voltage
signal output
SKEW Skewness, the asymmetry of the vibration signal As options, the frequency range can be extended to 40000Hz/12800
spectrum lines and possibility to save time signal.
NL1 - 4 Noise level in the four quarters of the frequency
range. Ordering numbers
LEO134 FFT with symptoms, unlimited use
Peak and peak-to-peak values are shown in the unit selected LEO234 FFT with symptoms, limited use
for the time signal. LEO139 12 800 lines, 40 kHz, option
LEO164 Time signal, option to FFT with symptoms

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2009-11. TD-220 B
Leonova™ Infinity – EVAM evaluated vibration analysis

EVAM stands for Evaluated Vibration Analysis Method. With Spectrum analysis with 'symptoms'
Leonova, the EVAM method is offered as an analysing func- For easy pattern recognition in spectra, EVAM supplies a
tion with either limited or unlimited use. range of ready made 'fault symptoms'. These are instruc-
tions to highlight a spectrum line pattern and display the
The EVAM method generates three sets of machine condi-
sum of the lines' RMS values as a symptom parameter
tion data:
(which can be evaluated and trended). Most symptoms are
• Condition parameters, which are measured and cal- automatically configured by using the rpm as a variable,
culated values describing various aspects of machine for some an input is needed, e. g. the number of vanes
vibration. on a rotor. Suitable symptoms and symptom groups are
• Vibration spectra where significant line patterns are selected from a menu in Condmaster when the measuring
found, highlighted and evaluated with the help of pre- point is set up.
set fault symptoms.
Machine specific condition codes
• Machine specific condition codes (green, yellow, red)
In Condmaster, alarm limits can be set on all active param-
and condition values, based on a statistical evaluation
eters. Once measuring results are collected, an EVAM 'cri-
of the condition parameters and symptom values.
terion' can be created that compares new parameter values
For each measuring point, the user can make an individual with the statistical mean value and displays a dimensionless
selection and define the type of data best suited for the condition value against a green - yellow - red scale.
surveillance of an individual machine.
Technical data
Frequency limit, lower: 0.5, 2, 10 or 100 Hz
Condition parameters
Frequency limit, upper: 100, 200, 500, 1000, 2000, 5000,
Condition parameters are measured for a selected frequen- 10 000, 20 000 Hz
cy range. They can be individually activated and are shown Envelope high pass filters: 100, 200, 500, 1000, 2000, 5000,
in measuring result tables and as diagrams. Available are: 10 000 Hz
Measurement windows: Rectangle, Hanning, Hamming, Flat Top
VEL RMS value of vibration velocity Averages: time synch, FFT linear,
FFT exponential, FFT peak-hold
ACC RMS value of vibration acceleration Spectrum lines: 400, 800, 1600, 3200, 6400
DISP RMS value of vibration displacement Frequency units: Hz, CPM, orders
Saving options: peaks only, full spectrum, time signal
CREST Crest value, difference between peak and RMS Spectrum types displayed: linear, power, PSD
KURT Kurtosis, the amount of transients in the vibration Zoom: true FFT zoom, visual zoom
signal Transducer types: Vibration transducer SLD144 or IEPE
(ICP®) type transducers with voltage
SKEW Skewness, the asymmetry of the vibration signal output

NL1 - 4 Noise level in the four quarters of the frequency As an option, the frequency range can be extended to 40000 Hz,
the number of spectrum lines to 12800.
range.
Ordering numbers
Peak and peak-to-peak values are shown in the unit selected LEO135 EVAM evaluated vibration analysis, unlimited use
for the time signal.. LEO235 EVAM evaluated vibration analysis, limited use-
LEO139 12 800 lines, 40 kHz, option

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-09. TD-221 B
Leonova™ Infinity – 2 channel simultaneous vibration monitoring

Two channel simultaneous vibration monitoring is a Technical data


Leonova Infinity function for limited (LEO236) or unlim- Frequency limit, lower: 0.5, 2, 10 or 100 Hz
ited (LEO136) use. It requires that either the measuring Frequency limit, upper: 100, 200, 500, 1000, 2000, 5000,
technique 'FFT with symptoms' or 'EVAM' is active. The 10 000, 20 000 Hz
function 'FFT with symptoms' requires the option 'Time Envelope high pass filters: 100, 200, 500, 1000, 2000, 5000,
signal' (LEO164) for possibility to display and save time 10 000 Hz
signal. Measurement windows: Rectangle, Hanning, Hamming,
Flat Top
This type of measurement allows the user to study machine Averages: time synch, FFT linear,
movement in two dimensions by observing the difference FFT exponential, FFT peak-hold
of the phase angles measured on the two channels. Spectrum lines: 400, 800, 1600, 3200, 6400
Saving options for spectrum: peaks only, full spectrum, time
signal
Measurement requires the set-up of two vibration assign-
Spectrum types displayed: linear, power, PSD
ments with identical parameters. The 2 channel measuring
Zoom: true FFT zoom, visual zoom
cable CAB51 is used to connect both transducers to the
Transducer types: Vibration transducer SLD144 or
Leonova vibration transducer input. The procedure is
IEPE (ICP®) type transducers with
the same as for the corresponding measurement with a voltage output
single transducer.
As an option, the frequency range can be extended to 40 kHz,
After measurement, Leonova displays the RMS values for the number of spectrum lines to 12800.
DISP, VEL and ACC for both channels. Three graphs are
available for each measurement: Ordering numbers
• Spectrum LEO136 2 channel vibration monitoring, unlimited use
• Phase spectrum LEO236 2 channel vibration monitoring, limited use
LEO139 12 800 lines, 40 kHz, option
• Time signal (option to FFT with symptoms)
LEO164 Time signal, option to FFT with symptoms
In the spectrum and the time signal, the channels are CAB 51 2 channel measuring cable, Lemo
overlayed red and blue.

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-09. TD-222 B
Leonova™ Infinity – Run up/coast down and Bump test

Run up / coast down measurements and Bump test are two Bump test
vibration analysis functions offered with Leonova Infinity, for The user sets the measuring range in Hz, which automatically
either limited or unlimited use. The bump test is employed sets the sampling time, e. g. 0.20 seconds for 2000 Hz/400
to check out the typical vibration response of a machine lines. A pre-trigging time, 5% to 25% of the sampling time,
structure at standstill, by hitting it e. g. with rubber mallet is also chosen.
(bump test). Run up/coast down records the changes in
The gain level is set by hitting the machine frame with vary-
vibration while the machine is run up to operating speed
ing force. The peak amplitude of the measured signal is
or after it has been shut off and is slowing to a stop. Both
displayed (velocity in mm/s) and a trigger level can be set
functions are selected from the menu of an ordinary vibra-
to 1% – 90% of the amplitude.
tion measurement assignment.
The actual test returns an FFT spectrum and a time signal
Run up / coast down
(sampling time plus pre-trigging time).
For this test, both the signal unit and the display unit for
the spectrum can be selected. Leonova Infinity uses both Technical data
digital and analog integration, so the signal unit can be set
Run up/coast down
independent of the transducer type used.
Frequency limit, lower: 0.5, 2 10 or 100 Hz
The measuring interval can be either time based (interval in Frequency limit, upper: 1 to 9999 orders
seconds) or speed based (interval in rpm). The speed range Measuring interval: speed or time based
is also chosen, e. g. 400 to 3000 rpm. Measurement windows: Rectangle, Hanning, Hamming, Flat
Top
The first result is a list of the numbered measurements, Spectrum lines: 400, 800, 1600, 3200, 6400, 12800
showing rpm and RMS vibration value. The date and time Spectrum types displayed: linear
of the first measurement are displayed.
Bump test
For each individual measurement, a spectrum can be called Frequency limit, lower: 2 Hz
up. Another list and diagram show the phase angles in Frequency limit, upper: 100, 200, 500, 1000, 2000, 5000,
degrees. Finally, the user can call up diagrams for vibration 10 000, 20 000, 40 000 Hz
amplitude and angle, showing all measurements in time Spectrum lines: 400, 800, 1600, 3200, 6400, 12800
sequence. In all diagrams, a blue dot shows the position of Spectrum types displayed: linear
the measurement marked on the list. Pre-trigger time: 5%, 10%, 20%, 25% of sampling time
Transducer types: Vibration transducer SLD144 or
IEPE* (ICP®) type transducers with
voltage output
* Integral Electronic PiezoElectric

Ordering numbers
LEO137 Run up/coast down and Bump test, unlimited use
LEO237 Run up/coast down and Bump test, limited use

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-03. TD-223 B
Leonova™ Infinity – Orbit analysis

15326

15315

CAB10

Orbit analysis is a vibration measurement function offered The orbit graph shows an overlay of the graphs for each
with Leonova infinity, for either unlimited (LEO138) or measured revolution plus their average. �������������
The user can
limited use (LEO238). The resulting orbit graph shows the select each individual revolution as well as the average
movement of the shaft’s centerline and is used to detect of all revolutions.
failures like rubs, unbalance, misalignment or oil whip on
machinery with journal bearings. The selected�����������������������������������������
graph is marked blue, with a blue arrow
showing the angle and the x/y values at that angle. The
The measurements are normally made on the buffered user can move the arrow on the screen via tap and hold
outputs of a machine protection system via the Orbit on the orbit graph.
Interface 15315. The interface is connected to the vibra-
tion and the tachometer inputs on Leonova. Signal inputs, When the orbit assignment is set up in Condmaster Nova,
channel X, channel Y and tachometer are connected via alarm limits can be set on the X and Y axis, resulting in an
BNC connectors. evaluated measurement (green - yellow- red scale).

Measurements can also be made with e. g. accelerometers Technical data


to get a two dimensional graph of machine movement. Orders: 1 to 5, default 1
Required are two channel simultaneous vibration meas- Filter types: None, band pass, low pass
urement and two transducers placed at an angle of 90° Signal unit: DISP, VEL, ACC
to each other, plus a trigger signal from a tachometer Trig threshold: Automatic
probe.
Measuring time: 1 to 25 revolutions
RPM range: 15 to 20 480 rpm
Settings include transducer type, signal unit and filter
Transducer types: Buffered outputs from ����������������
API670 approved
type, either bandpass (default) or lowpass. Orders is set protection systems via Orbit Interface
to 1 by default, but the user can select from 1 to 5 orders. 15315, alternative vibration transducers
The number of revolutions parameter, max. 25, specifies SLD144 or IEPE (ICP®) type transducers
the number of shaft revolutions to acquire and display in with voltage output
the orbit graph.
Ordering numbers
During measurement, the result window shows displace- LEO138 Orbit analysis, unlimited use
ment in the x and y direction per revolution. When the LEO238 Orbit analysis, limited use

measurement is complete, the average of the measured 15315 Orbit Interface with belt clip

number of revolutions is shown. 15326 Set of measuring cables, 3 x BNC - BNC


CAB10 Tachometer cable, spiral

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-03. TD-224 B
Leonova™ Infinity – Balancing

Single and dual plane balancing are optional Leonova Leonova guides step-by-step through the balancing pro-
functions with either limited or unlimited use. In case of cedure. One can shift the rotation direction and change
limited use, credits are deducted for each vibration meas- the measured parameter from velocity to acceleration or
urement. displacement.

Single plane balancing, 4 runs In addition to the RMS value, a spectrum is shown to help
This method uses one measurement without trial weight to find the part of vibration that is due to unbalance. For the
determine the vibration severity (mm/s RMS) of the rotor, two run methods, the number of samples for obtaining a
followed by three measurements with trial weights at 0°, time synchronous average is set to min. 4.
120° and 240° to calculate the weight and position of the Leonova calculates a number of alternatives for correcting
correction mass. the unbalance:
• Trial weight: Input rotor diameter, weight and rpm to
Single plane balancing, two runs
obtain the suitable trial weight in grams.
This method uses one measurement without trial weight
to determine the vibration severity (mm/s RMS) of the ro- • Split the correction mass: Input the number of rotor
tor, followed by one measurements with a trial weight to partitions to distribute the correction mass between
calculate the weight and position of the correction mass. It two of them.
requires time synchronised vibration measurement (trigger • Weight removal: Drill hole diameter and depth calcu-
pulse supplied by a pulse from the SPM tachometer probe lated for various materials.
or a proximity switch) to find the relative phase angle be-
• Radial displacement: Input the change in radial distance
tween the two vibration measurements.
to recalculate the weight.
Dual plane balancing • Degrees to length: change from angle to length meas-
The same two run method as used for single plane bal- ured along the rotor circumference.
ancing, but with vibration measurement and weight cor- • Keep trial weight: Calculate the correction mass with
rection in two planes. These measurements can be made
the trial weight remaining in place.
by shifting the vibration transducer or by connecting two
transducers. • Sum up weights: Replace all correction masses on the
rotor by one.
For all methods, a final run can be made to check the balanc-
ing results and, if needed, get the data for further adjust- Ordering numbers
LEO152 Balancing, single plane, unlimited use
ments. Leonova then saves a balancing log file.
LEO252 Balancing, single plane, limited use
LEO153 Balancing, dual plane, unlimited use
LEO253 Balancing, dual plane, limited use
LEO154 Balancing, single and dual plane, unlimited use
LEO254 Balancing, single and dual plane, limited use

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-226 B
Leonova™ – Shaft Alignment

Shaft Alignment is an optional LeonovaTM function for quick Ordering numbers, LeonovaTM Infinity
and easy shaft alignment, with either limited or unlimited LEO155 Shaft alignment, unlimited use
use. In case of limited use, credits are deducted for each
LEO255 Shaft alignment, limited use
alignment assignment. The function is user-friendly and easy
to learn.
Ordering numbers, LeonovaTM
The LineLazer Accessory Set contains detector/transmitter LEO220 Shaft alignment, unlimited use, upgrade
units, brackets, chains, rods, cables and a measuring tape, LEO420 Shaft alignment, limited use, upgrade
all in a carrying case. This set fits a multitude of applications,
e.g. compressors, gearboxes, generators, and pumps. LineLazer Accessory Set LLA300
The detector units have position detectors (PSD) with a large LLB30 1 pc. LineLazer detector, lower beam (TD-267)
reception area, which makes fine tuning unnecessary. Com- LLB31 1 pc. LineLazer detector, upper beam (TD-267)
pensation values for thermal growth can be input. Integrated LLB11 2 pcs. Extension chain, length 1000 mm
precision inclinometers measure the angle of rotation of both LLB12 2 pcs. Chain with tension adapter, length 500 mm
detector units at all times. This allows measurement in fully LLB13 1 set Supporting rod, 80 mm, set of 4
automatic mode, with much less than a half-turn of the shaft. LLB14 1 set Supporting rod, 150 mm, set of 4
Measurement results are displayed in 100ths of millimetres
LLB15 2 pcs. Shaft bracket for chain
or 1000ths of an inch.
CAB50 1 pc. Communication cable between LineLazer
The Leonova instrument is the control and display unit. The and Leonova Infinity, length 3 m
interaction between the graphical display and the user is kept CAB75 1 pc. Charger cable, length 1.5 m
as simple as possible. A self-explanatory display based on MAA70 1 pc. Measuring tape
icons and graphics guides the user to make a perfect shaft TOL21 1 pc. Torquing tool for chains and rods
alignment. Leonova produces a log file with all alignment
CAS19 1 pc. Carrying case, plastic with foam insert
data for documentation and printing.

Measurement programs: Battery charger


• Alignment of horizontally mounted machines (automatic 90362 Charger, 100-240 V AC, 50-60 Hz, Euro-plug
measurement or manual promts) 90379 Charger, 100-240 V AC, 50-60 Hz, US-plug
90380 Charger, 100-240 V AC, 50-60 Hz, UK-plug
• Alignment of vertically and flange mounted machines
• Softfoot measurement Options
• Compensation for thermal growth Magnetic brackets, offset brackets 50 mm and offset
• Feet lock function brackets 100 mm on request.
• Shaft alignment log
Spare parts
LLB20 Supporting rod, 80 mm
LLB21 Supporting rod, 150 mm

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2008-03. TD-227 B
Leonova™ Infinity – Recording function

A B

Recording is an optional Leonova function with unlimited In the example shown above the measuring point is con-
use. It allows the user to measure simultaneously with figured for the techniques SPM dBm/dBc with spectrum
up to three different transducers and record measuring (which automatically asks for a speed measurement), for
results for as long as the battery charge will last. Thus, ISO 2372 vibration measurement and for EVAM vibration
'Recording' is an analysis tool that can show the interac- measurement.
tion of various condition parameters over time.
Under 'Total' in the recording window, the desired number
Leonova has three separate input connectors, for of measurements is input, alternatively the total recording
• shock pulse measurement time in minutes.
• speed or temperature measurement Under 'Time between measurements' the interval is input
• vibration or analogue measurement. in minutes. 0 minutes means 'as fast as possible'.

Thus, shock pulse recording can be combined with either The measuring sequence is set by opening the list of avail-
of the alternatives given by the other two input. able measuring techniques with NEW (A) and selecting
techniques in any order. A technique can be used more
The recording function for a single quantity, e. g. tem- than once in the sequence.
perature, can be reached and set up from the default
Recording is started with the 'Measure' key and can be
file saved under the respective technique window. To
terminated with the 'Cancel' key (B).
record different quantities at the same time, one needs
a measuring point file where all the different techniques Leonova displays the number of measurements taken
are activated. and powers down when all are recorded. The batch is
then saved by the user and can be transferred to Con-
dmaster.

Ordering number
LEO160 Recording function, unlimited use

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-228 B
Leonova™ Infinity – Order tracking

Order tracking is an optional Leonova function primarily In the example shown above the measuring point is con-
used for vibration analysis on variable speed machines. The figured for vibration analysis with order tracking. Under
method uses multiples of rotational speed (orders), rather ‘Measuring point data’ order tracking is marked and the
than absolute frequency (Hz). The number of orders to be upper frequency is input in orders. The lower frequency is
shown is input by the user. Leonova will then automatically input in Hz or CPM under ‘Measuring point data’. ‘Variable
set the sampling frequency to an exact multiple of the speed’ must be marked and rpm has to be measured.
measured rpm. Order tracking will also minimise the risk
Leonova displays the spectrum within the selected number
of smearing when using FFT averaging.
of orders. A number of measurements can be displayed in
The purpose of using orders is to lock the display to the a three dimensional waterfall diagram, where 1X (rpm) and
rotational speed (1X) and its multiples, which means that its harmonics remain in the same position in the diagram.
the ordered components in the spectrum always remain The measurements are then saved by the user and can
in the same position in the display, even if the rotational be transferred to Condmaster. Setup of order tracking
speed varies between the measurements. assignments in Condmaster require the optional software
module, MOD188 Order tracking.
Two or several spectra from the same machine with variable
speed can therefore more easily be compared if they are
expressed in orders. Using order tracking, the frequency Ordering number
range will always cover the symptoms of interest, regard- LEO165 Order tracking, unlimited use
less of the rotational speed of the machine.

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2009-02. TD-306 B
Leonova™ Infinity – Services

The service program Leonova.exe is part of the basic function The credits required for a measuring round and the tank
package for Leonova Infinity. It is used to status are displayed by Leonova under 'Function and use'.
There one can also set the values and time intervals for the
• print balancing and alignment reports.
´tank low´ warnings.
• load credits and/or functions from the file ‘Leonova.txt’
The amount of credits deducted when the 'Measure' com-
• upgrade a Leonova version from the file ‘P70.EXE’.
mand is given depends on the method used, see table. For
• display and print a credit log containing all events in balancing, credits are deducted for each vibration reading.
connection with measurements credits, up to 10000. The table shows the min. requirement.
• make and reload safety copies of the Leonova files (file
extension .lsc). Functions with limited use Credit consumption

The operation of the service program is very simple: con- Shock pulse method dBm/dBc 1
nect Leonova to the PC, put it in communication mode, then Shock pulse method LR/HR 2
click on the desired service function. Follow the guidance SPM Spectrum 2
on the screen. Vibration ISO 10816 with spectrum 1

A safety copy of the Leonova measurement file can be used EVAM evaluated vibration analysis / time signal 2
to export one or more measuring points and, for example, FFT with symptom 2
send them to SPM for technical advice. 2 channel simultaneous vibration measurement 4
Orbit analysis 5
The file ‘Leonova.txt’ can contain measuring credits and/or
Leonova function that are new for the instrument or changed Run up/Coast down 50
from limited to unlimited use. It is coded to fit the individual Bump test 25
instrument and ordered via the local SPM distributor. Balancing, 1 plane 4 runs 16
Balancing, 1 plane 2 runs 42
Ordering number Balancing, 2 plane 80
PRO49 Leonova Service Program Shaft alignment 30

SPM Instrument AB • Box 504 • SE-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2006-03. TD-229 B
Leonova™ Infinity – Protective cover 15310

15310

Protective cover 15310 is an optional accessory for the Technical specifications


hand-held machine condition analyser LeonovaTM Infinity. Material: Polyester fabric with foam lining and
The cover, made of foamed polyester fabric, protects the
window of soft transparent PVC foil
instrument against shocks, splashes and dirt (IP64). The
transparent plastic window makes Leonova easy to operate Fastenings, seals: Velcro tape, polyamide
via the keypad and can be opened to facilitate the use of Weigth: 95 g
the touch screen. The cover is provided with holders for
wrist strap and stylus.

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2008-09. TD-246 B
Leonova™ Infinity – Transducers and measuring cables

TEN10

SLD144B TEN11
SLD144F TEM11
CAB51

CAB48

TRX16
TAD12 14765

TAD10
TRA70

TRX17
TAD18 TAD15
TRA72

TAD11 81319

Transducers and measuring cables for Leonova™ Infinity For shock pulse monitoring, only use original SPM shock
are selected in accordance with the individual instrument's pulse transducers. For vibration monitoring, any vibration
range of measuring functions. The ordering numbers are transducer with voltage output can be used.
listed below.

Shock pulse monitoring Current and voltage monitoring


TRA70 Shock pulse transducer with quick connector for CAB42 Cable for analog signals
measuring adapters
TRA72 Shock pulse transducer with probe Speed monitoring
CAB36 Measuring cable, BNC slip-on, 1.5 m TAD10 Contact adapter for tachometer probe
EAR10 Earphone in ear defenders, headset, with cable TAD11 Contact centre, rpm, short
EAR11 Earphone in ear defenders, for helmet, TAD15 Contact centre, rpm, long
with cable TAD12 Contact wheel, meter / min.
TAD13 Contact wheel, yards / min.
Vibration monitoring TAD17 Contact wheel, feet / min.
SLD144B Vibration transducer M8 (2-10 000 Hz) TAD14 Reflecting tape, pad of 5 sheets
SLD144F Vibration transducer UNF 1/4"-28 (2-10 000 Hz) TAD16 Reflecting tape for thin shafts, 5 sheets
TRX16 Magnetic foot for vibration transducer M8 TAD18 Tachometer probe with cable
TRX17 Probe for vibration transducer M8
CAB48 Measuring cable, spiral, angle Lemo-2 pin Balancing
CAB48-L Measuring cable, Lemo - 2 pin (L = length in m) CAB43 Cable for TAD18, length 5 m
CAB51 2 channel measuring cable, Lemo 81319 Magnetic base
CAB41 Communication cable for 'iLearn' 14765 Holder fot tachometer probe TAD18

Temperature monitoring Spare parts


TEN10 Temperature probe tip, surface 13108 Sleeve for probe tip (TRA-72)
TEN11 Temperature probe tip, liquid CAB37 Cable for TRA-72, 1.5 m (5 ft)
TEM11 Temperature probe with cable CAB10 Spiral cable for TAD-18, TMM-11

SPM Instrument AB • Box 504 • S-645 25 Strängnäs • Sweden Technical data are subject to change without notice.
Tel +46 152 22500 • Fax +46 152 15075 • info@spminstrument.se • www.spminstrument.com ISO 9001 certified. © Copyright SPM 2005-12. TD-247 B
Leonova™ Infinity – LineLazer II detector units

LLB31 LLB30

9
85

20
28 13

54
116

LineLazerII LLB30 and LLB31 are two detector/transmitter Technical specifications


units for shaft alignment with the multi-function datalogger Laser type: line laser, visible red light
Leonova™. The detectors are identical with exception of Laser power : <1 mW
the position of laser diode and sensor. Laser safety class: Class 2
Laser wavelength: 635 to 657 nm
Using a horizontally spread laser beam in combination
Laser modulation: 200 kHz
with a 37 mm vertical sensor (PSD) makes fine tuning un-
Sensor resolution : 1 µm
necessary. The laser beam is modulated and thus easily
and automatically distinguished from interfering light Sensor linearity : < 2% deviation
sources. The laser beam is not mirrored, both units are Sensor size : 37 x 1 mm (1.5 x 0.03 in)
true detectors/transmitters. The communication between Operating range : 50 to 3000 mm (2 to 120 in)
them is wireless, only one of the units is cable connected Inclinometer resolution : 0.5°
to Leonova.
Batteries: NiMH rechargable
Operating time : > 16 hours normal use
The detector units have integrated double axis precision
Operating temperature: 0 to +50 °C (32 to 122 °F)
inclinometers which measure the angle of rotation of both
detector units at all times. This allows measurement in Storage temperature: -25 to +55 °C (14 to 140 °F), non
condensing
fully automatic mode, with much less than a half-turn of
the shaft. Measurement results are displayed in 100 ths of Keyboard: sealed membrane
millimetres or 1000 ths of an inch. Control indicators: LED, red/green
Connector type: LEMO 5 pins, for communication
The control panel on the detector has a power off switch with Leonova and battery charger
and LED indicators to show correct aim, battery status, Housing: aluminium, blue anodized
and communication mode. The batteries are recharged Protection: IP65
with the standard Leonova Infinity chargers SPM 90362 Dimensions: 116 x 94 x 54 mm (4.6 x 3.7 x 2.1 in)
(EU), 90379 (US) or 90380 (UK).
Weight: 450 g

Patent No.: US7301616, SE 0400586-4