Thank you for choosing another quality product from Amperes Electronics.
iPX5151 is an Ethernet Paging Client which receives and transmits paging audio and RS485 data from digital paging microphone,
which is then fed to a receiving paging client via Ethernet connection. The receiving client can then broadcast the audio via PA mixer
for amplification.
iPX5151 is now refreshed with newer technology for Ultra Low Latency audio transmission, thus reducing the delay in sound delivery.
Parameter settings are done using web browser, connected directly to the unit for channel setup, bass and treble controls, volume, etc.
Rear View
Front View
8
1 2 3 4 5 7 9 10
6
1. INDICATOR LEDS
POWER - This blue LED shall lit when iPX5151 is powered On.
SERVER - This green LED shall lit when iPX5151 successfully establish a connection with Paging Server (iPX5101).
STATUS - Blink whenever there is a network activity ongoing.
STREAMING - Blink whenever iPX5151 start streaming audio to a receiving paging client (iPX5155).
2. POWER PORT
24V DC power supply input.
3. ETHERNET PORT
Ethernet port for connecting to network switch.
4. RESET BUTTON
Button to allow iPX5151 enters Bootloader mode or reset settings to factory default settings.
Bootloader mode: To enter this mode, hold the reset button until POWER, SERVER and STATUS LEDs lit. Enter this
mode to do firmware updating if normal mode updating does not work. All iPX5151 settings remain intact in this mode.
Reset to factory default settings: Hold the reset button until POWER, SERVER, STATUS and STREAMING LEDs lit
will reset all iPX5151 settings to factory default settings.
5. RELAY CONTACT
This ports provide a dry contact which can be used as E/M overriding signal or activate ALL CALL at speaker zone selector.
7. RS485 PORT
For data transmission between PD paging mic and iPX5151.
8. SIGNAL INDICATOR
This LED shall blink according to the rhythm of the input paging mic audio.
9. AUDIO INPUT PORT
Connect paging mic or other audio source analog audio to this port. The signal shall be in balanced line level.
10. AUDIO OUTPUT PORT
Audio that sending to Audio Input Port shall also broadcast via this output port. The signal is in balanced line level.
DC 24V
100mA
RELAY
CALL
POWER
SIG
PAGING
CHIME
MEDIA PLAYER
MP3 / TUNER / CD
MR1301
MESS. PLAYER
EP1200 EMER.
PAGING MIC
cat5e
amperes
a m pe re s
MIC
POWER
REM
STATUS
ACT
SIREN SWITCH
SIREN
FIRE
cat5e
EP 1200
iPX5200 MUSIC
SERVER
iPX 5 1 0 1
iPX5151
cat5e
NETWORK SWITCH WITH FIBER LINK
Fiber redundant loop ( not available to all switchers )
iPX5300
RESET
T
ETHERNE
MAIN RACK
Music
LOCAL PA EQUIPMENT INCL. Audio
PRE-AMPLIFIER MIXER ZONE
amperes
iPX
530
ETHERNE
ETHE 0
RNET
T ADDRESS
MUS D LINE
IC CLIE BALANCE
OUTPUT
NT
RESET
T
ETHERNE
SUB RACK
Note:
In a system, only one iPX5101 is required, no matter what the size of the system or the number of clients ( iPX5151 / iPX5155)
are installed.
iPX5151 | ETHERNET PAGING CLIENT PAGE 3
Device Setup Via Browser
iPX5151 shall require some setups via web browser. Kindly follow instruction listed below.
Open a browser (Chrome / IE) and enter iPX5151 IP address. The default address is 192.168.0.100. Default username and password
are both “admin”.
The first page appear upon login shall be Device Info. Informa- Edit iPX5151 IP address, Subnet address and Gateway
tion such as firmware version, networking addresses and address here to suit you networking environment. It is recom-
paging server status are shown. No configuration is needed in mended to leave the Data port number unchanged. Click the
this page. ‘SAVE’ button to save your changes.
IP Address
Gateway Address
Data Port
Auto Connect: We can either turn On the Auto Connect to allow iPX5151 search
and connect to Paging Server automatically or turn Off the setting and specify the
Paging Server IP address here.
Paging Enabled
Note: If paging Server IP address is changed to an unknown value, turn On the
Auto Connect allow iPX5151 auto capture the server IP address and show up in the Auto Connect
device information page. Paging Server IP Address
192.168.0.101
Remote Trigger
Enabled: If PM1000 or TI6100 were used as the paging audio source, enable this
setting such that iPX5151 Remote Trigger port accept the devices triggering via dry
contact.
No Priority: There are 13 priority levels. No priority is the 13th level which is the
lowest. Disable this setting allow us to set a higher level for paging device that
connected to this iPX5151. The lower the priority number, the higher the priority
level.
Enabled
Auto Override Low Priority (AOLP): Enable this setting if we want to allow
device that connect to this iPX5151 Remote Trigger port to override other lower No Priority
priority devices. More about AOLP can refer to iPX5101 instruction manual.
Priority
Device Name
Room A Paging Client
System
Unit Configuration: We can enter a meaningful Device Name here, e.g. “Room
A Paging Client”. The name will be shown in Device Info page of iPX5151 and iPX5101
Enter new username
Paging Server - Client Browser tab.
Enter new password Authentication: You can alter the user name and password to avoid unnecessary
access to the system.
Update Firmware: Firmware is stored in the unit’s memory. Should there be any
updates available, use this section to perform system upgrades accordingly. Refer
page 6 on firmware updating.
Backup & Restore: You can backup the configuration and can reset the settings
to default settings.
Click “ SELECT FIRMWARE” and choose a binary file with “.acfr” extension. Click
“UPLOAD”.
iPX5151.acfr
Once the update is completed, the browser should enter the login page.
IPX5151.acfr
IPX5151.acfr
Click the Upload Firmware button to find the Find the updated firmware file.
updated firmware file.
IPX5151
IPX5151
2.06
Updating progress
Power requirement :
Voltage 18 ~ 24V DC (Normal DC 24V)
Current 60 mA
Power consumption 1.5W
Connection
- LAN interface RJ45 (10 / 100 Base - T)
- Protocol TCP/IP, UDP, HTTP, IGMP, ADMP
Audio
- Analog in (max) 3.2Vrms
- Analog out 1Vrms (with Analog in 850mVrms)
- Input impedance 90 Ohm
- Input capacitance 100 pF
- Total harmonic distortion (THD) 0.1%
- S/N ratio (full scale signal) 83 dB
- Paging encoding G.722
Operating condition :
Temperature -20°C ~ 80°C
Humidity 0 - 70%
Case :
Dimension (WxHxD) 100 x 147 x 40 mm
Weight 300 g
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as
removal and installation of the product from the main system are for the account of the purchaser. This warranty
shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the
product with power supply voltage other than shown on the product, or any other power supply source / adaptor
not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly
related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the
unit; moreover the warranty does not cover any damages which may be caused to people and things when using
the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on this
certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from the
date of purchase or for a specified period in countries where this is stated by a national law. In this case, the
extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the
design changes or improvements are made.
Disclaimer
Information contained in this manual is subject to change without prior notice and does not represent a commitment
on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages
whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN
BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction
with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by
service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.