GS2000 CO2 Insufflator

Reusable In-Line
Warmer System

Insufflation Tubing Set

CPS™ Tubing Set

Medical Grade CO2 gas is After connecting the Activate power to the unit
1 used for insufflation. Gas 2 hospital grade power cord 3 by touching the front of
is delivered to the insuf- to rear of unit and to a the LCD screen. Prior to
flator from CO2 cylinders properly grounded power activation, the LED on-off
or from a central supply source, turn on the main indicator located at the
wall source located in power switch at the rear lower left of the screen
each operating room. of the unit as shown. is “blue”.
A high pressure hose is
easily connected to the
supply source and to the
rear of the insufflator.

Once the LCD screen After the self-diagnostic Once the appropriate
4 is activated, the LED 5 check is completed, the 6 operating mode
on-off indicator located “Select Operating Mode” is selected, the user
at the lower left of the screen will appear. The must confirm the
screen turns “green”. user will need to choose selected mode.
The insufflator will now from 5 different modes:
complete a very brief - General Laparoscopic
self-diagnostic check. - Bariatric
- Pediatric
- Vessel Harvest
- Custom

The operating mode Using the “Up and Down” Prior to use, the dispos-
7 screen appears displaying 8 arrows allows for pres- 9 able, filtered insufflation
preselected Pressure sure and flow adjust- tubing set needs to be
and Flow rates. Factory ments at any time. connected as shown.
set defaults can be used
or new user preferences
can easily be stored using
the “Set-Up Menu.” Easy
toggling through Verres,
High and Maximum Flow
settings are made using
the “Flow Preset” icon.

If “Continuous Pressure Warming the CO2 gas can The In-Line Warmer
10 Sensing” is required, the 11 help to reduce post- 12 is connected 3-4
disposable, filtered CPS™ operative patient pain, inches from the distal
tubing set is connected. reduce PACU recovery end of the tubing.
CPS™ is essential to insure time and reduce fogging
rapid recovery of any lost of the laparoscope.*
intra-abdominal pressure, A reusable In-Line Gas
reducing the breathing effect Warmer is available and
of the abdominal surface is easily connected to the
and for totally uninterrupted front panel of the insuffla-
pressure monitoring. CPS™ tor as shown.
is highly recommended for
pediatric laparoscopy.*

To initiate gas flow for To stop the flow of gas, The user can access
13 insufflation, depress the 14 depress the orange “stop” 15 the set-up menu at
green arrow as shown. button. The flow of gas any time by depressing
The insufflator will deliver is now paused. To start the SET-UP MENU icon
gas to maintain the gas flow again, simply located in the lower left
desired pressure. depress the green arrow. corner of the screen.

The “Set-Up Menu” Default settings can be When finished using the
16 allows adjustments to: 17 changed and stored while 18 GS2000 insufflator prod-
- 5 Alert Volume levels in the “Program Defaults” uct, depress the POWER
- 14 Language choices screen. Restoring the DOWN icon located at
- Viewing Service factory defaults can be the upper left side of the
Contact Information done by depressing the screen. To re-start the
- Operating Mode Default “Restore Factory Default” unit, see step #1.
- Gas supply options icon as shown.

Specifications Certifications
50L Insufflator Console (GS2000) CO2 Warmer (GS1012) UL 60601-1
CAN/CSA C22.2 NO. 601.1
Dimensions: 12 in. (w) x 6 in. (h) x 12 in. (d) Gas Temperature: 95-106°F (non-adjustable) (35-40°C) IEC (EN) 60601-1 IEC (EN) 60601-1-2
(305 x 153 x 305 mm)
Dimensions: 1.0 in. (d) x 3.4 in. (l)
Weight: 11.5 lbs. (4.3 kg)
Weight: 2.0 oz. (56g)
Input Voltage Range: 90-240 VAC, 50-60 Hz
Protection Class: Class I, Type B Applied part
Electrical Leakage: 100 micro amps maximum

CAUTION: This guide is not a replacement or substitute for the ConMed GS2000 operator’s manual. Please be sure to read and understand the GS2000 operator’s manual thoroughly before using the insufflator.

Ordering Information
Description Catalog Number Description Catalog Number

50L Insufflator GS2000 Insufflation Tubing Set, disposable, CPC/Luer, w/filter GS1016
Hose and Yoke for CO2, E-Tank, 4 ft. GS1052 Insufflation Tubing Set, disposable, Luer/Luer, w/filter C7010**
Dual Tank Shuttle Valve System GS2050 Insufflation Tubing Set, disposable, IEC/Luer, w/filter C7011**
CPS Tubing Set, disposable, w/filter GS1013
CO2 Warmer, in-line, reusable GS1012
Cleaning Brushes for Warmer assembly, 10/pkg GS1054

Adapter, CPC to IEC (for C7011 tubing) GS1050 *Data on file


Adapter, CPC to Luer (for C7010 tubing) GS1051 **C7010 tubing requires a GS1051 adapter. C7011 tubing requires a GS1050 adapter.