Lighting Analysis of City Campus: Subhana, Nabiha, Sabeen, Samrah, Iqra, Fatima, Aimen

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

Lighting analysis of

city campus

Subhana, Nabiha, Sabeen, Samrah, Iqra,


Fatima, Aimen
Site Orientation
N

Summer Sun

Winter Sun
Building #01: Ground Floor plan

1 2 3 4
Building #01: First Floor plan

1 5 6 7
Building #02: Ground Floor Plan

8 10 11 12 13 14 15
Building #02: First Floor Plan

17 18 19 20 21
Artificial lighting
The most abundant light source in the studios of
city campus is the diffused lighting through the
numerous casement windows.

Since the studios are used for architectural work


like drafting and model making, a sufficent amount
of lighting is required
Natural lighting
Despite abundance of artificial lighting, the studio receives
a decent amount of natural light through windows.

The studios on the first floor recieve a lot more daylight


due to larger windows from atleast three directions and
direct sunlight.

The ground floor studios, specially the 4th year studio,


despite its numerous windows does not receive much
daylight, as several windows fulfil their ventilation purpses
more fully then they provide light
ROOM 1: CHIMNEY ROOM
NO. OF WINDOWS 12

NO. OF ARTIFICIAL 12
LIGHTS
TYPES OF LIGHTS FLUORESCENT(08) &
FLOOD(04)

NO. OF DOORS 03

NATURAL LIGHT EXCESSIVE

COOLING SYSTEM PASSIVE

SUGGESTION DISPLAY ROOM; ADD


SUFFICENT ARTIFICIAL
LIGHTS TO CREATE
BETTER FOCUS ON
DISPLAY; FOCAL
LIGHTING
ROOM 3: 3RD YEAR STUDIO
NO. OF WINDOWS 6

NO. OF DOORS 3

TYPES OF LIGHTS FLUORESCENT

NO. OF ARTIFICIAL 40
LIGHTS
LIGHTS ABOVE 36
MEZZANINE FLOOR
LIGHTS UNDER 22
MEZZANINE FLOOR
SUGGESTION MORE LIGHTS UNDER
MEZZANINE FLOOR
FOR OPTIMUM
PRODUCTIVITY AND
WORKING
CONDITIONS
ROOM 4: 4TH YEAR STUDIO
NO. OF WINDOWS 15

NO. OF DOORS 3

TYPES OF LIGHTS FLUORESCENT

NO. OF ARTIFICIAL 42
LIGHTS
NO. OF LIGHTS UNDER 12
MEZZANINE FLOOR
NO. OF LIGHTS BELOW 18
MEZZANINE FLOOR
SUGGESTION OPENINGS REQUIRED
NEAR DOORS FOR ORE
DAYLIGHT. EXISTING
HANGING LIGHTS TO
BE REPOSITIONED SO
LIGHT IS NOT BLOCKED
BY COLUMNS OR
OTHER
OBSTRUCTIONS
ROOM 5: 2ND YEAR STUDIO
NO. OF WINDOWS 9

NO. OF DOORS 4

TYPES OF LIGHTS FLUORESCENT

NO. OF ARTIFICIAL 36
LIGHTS
VENTILATION GOOD
RATING
WINDOW EASILY OPENABLE
ARTICULATION
SUGGESTION ARTIFICIAL LIGHTS TO
BE EITHER OF HIGHER
WATTS OR BE HUNG
LOWER FOR MORE
DIRECT LIGHT
ROOM 6: 1ST YEAR STUDIO
NO. OF WINDOWS 12

NO. OF DOORS 3

TYPES OF LIGHTS FLUORESCENT

NO. OF ARTIFICIAL 38
LIGHTS
VENTILATION GOOD
RATING
WINDOW EASILY OPENABLE
ARTICULATION
SUGGESTIONS ARTIFICIAL LIGHTS
TO BE EITHER OF
HIGHER WATTS OR
BE HUNG LOWER
FOR MORE DIRECT
LIGHT
ROOM 8: FIRST YEAR DS
NO. OF WINDOWS 07

NO. OF ARTIFICIAL 06 (DOUBLE HANGING)


LIGHTS 06 (FIXED)
TYPE OF LIGHTS HANGING & FIXED

NO. OF DOORS 01

COOLING SYSTEM PASSIVE

NATURAL LIGHT RATING LOW

SUGGESTION ARTIFICIAL LIGHTS


INSUFFICIENT. ADD
WARMER LIGHTS TO
LIGHTEN DAMP MOOD
CREATED BY
TUBELIGHTS
ROOM 9: CHAIRPERSON OFFICE

NO. OF WINDOWS -

NO. OF ARTIFICIAL 07 (DOWNSTAIRS)


LIGHTS 05 (UPSTAIRS)
TYPE OF LIGHTS FLUORESCENT

NO. OF DOORS 02

COOLING SYSTEM ACTIVE

NATURAL LIGHT MODERATE


RATING
SUGGESTION
ROOM 10:
POSTGRADUATE LAB
NO. OF WINDOWS 03

NO. OF ARTIFICIAL 05
LIGHTS
TYPE OF LIGHTS HANGING

VENTILATION CROSS AND GOOD


TYPE/RATING
NATURAL LIGHT MODERATE
RATING
SUGGESTION
ROOM 11: COMPUTER LAB
NO. OF WINDOWS 0

NO. OF ARTIFICIAL 56
LIGHTS
ENTRANCE SOUTH
PROFILE
WINDOW PROFILE -
NATURAL LIGHT -
TYPES OF LIGHTS FLUORESCENT

NO. OF DOORS 02
COOLING SYSTEM ACTIVE

SUGGESTION ADD SLIGHTLY WARMER


ARTIFICIAL LIGHTS TO LIVEN FOR
MORE PRODUCTIVITY. BRIGHTER
LIGHTS ENOUGH TO MAKE WORK
COMFORTABLE, BUT ALSO TO
AVOID GLARE ON SCREENS
ROOM 12: MEETING ROOM
NO. OF WINDOWS 02

NO. OF ARTIFICIAL 06
LIGHTS
TYPE OF LIGHTS LED

NO. OF DOORS 03

SUGGESTION DRAB LIGHTING;


CREATE OPENINGS
FOR DAYLIGHT AND
TO BETTER
WORKING
CONDITIONS.
ARTFICIAL LIGHTS
ALSO NOT
SUFFICIENT FOR
STUDYING
ROOM 13: HERITAGE CELL
NO. OF WINDOWS 02

NO. OF DOORS 01

ENTRANCE PROFILE SOUTH

WINDOW PROFILE NORTH

NO. OF ARTIFICIAL 07
LIGHTS
SUGGESTION SPACE AVAILABLE
FOR MORE OPENINGS
TO LET IN DAYLIGHT.
ROOM USED AS
DISPLAY FOR
DRAWINGS AND
MODELS; LIGHTING
NOT ENOUGH TO
OBSERVE DETAILS
ROOM 15: ROOM BELOW ARCHIVES
NO. OF WINDOWS 08

NO. OF DOORS 02

ENTRANCE PROFILE SOUTH

WINDOW PROFILE EAST

NATURAL LIGHT UTILIZED TO BENEFIT (AS


THE DOOR IS AT SOUTH)

WINDOW ARTICULATION EASILY OPENABLE

VENTILATION RATING GOOD

NO. OF ARTIFICIAL 09(SINGLE)


LIGHTS

SUGGESTION ARTIFICIAL LIGHTS


INSUFFICIENT. ADD
WARMER LIGHTS TO
LIGHTEN DAMP MOOD
CREATED BY TUBELIGHTS
ROOM 17: SEMINAR HALL
NO. OF WINDOWS 01

NO. OF ARTIFICIAL 12
LIGHTS
TYPE OF LIGHTS LED

NO. OF DOORS 01

NATURAL LIGHT MODERATE


RATING
SUGGESTION LOWER OPENINGS
FOR SLIGHTLY
MORE DIRECT
DAYLIGHT ONTO
WORKING
SURFACES
ROOM 19: EXHIBITION HALL
NO. OF WINDOWS 34

NO. OF ARTIFICIAL 23
LIGHTS
TYPE OF LIGHTS FLUORESCENT

NO. OF DOORS 02

WINDOW PROFILE SOUTH

NATURAL LIGHT MODERATE


RATING
SUGGESTION DISPLAY OR FOCAL
LIGHTING
REQUIRED FOR
EMPHASIZING
EXHIBIT PIECES
ROOM 21: ARCHIVES
NO. OF WINDOWS 19

NO. OF DOORS 4

TYPES OF LIGHTS FLUORESCENT

NO. OF ARTIFICIAL 18(SINGLE) +


LIGHTS 9 (DOUBLE)
VENTILATION GOOD
RATING
WINDOW ARTICULATION EASILY OPENABLE

PROFILE OF NORTH CLOSED


WINDOWS
PROFILE OF SOUTH COVERED WITH
WINDOWS BLINDS
SUGGESTION ADD OPENIGS OR
ARTFICIAL LIGHTS TO
COUNTER EXISTING
DIMNESS