Professional Documents
Culture Documents
DWG Hvac Pump Station
DWG Hvac Pump Station
R
OWNER
-
A
WIRE MESH SCREEN WIRE MESH SCREEN WIRE MESH SCREEN WIRE MESH SCREEN
1
C:\Users\Nabil\Desktop\logo.png
AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW
0
E.A.D 38"X12" E.A.D 38"X12" E.A.D 38"X12" E.A.D 38"X12"
1
AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW
-
H
F2 F2 F2 F2
M
MAIN COSULTANT
PROJECT
ID-PICO-001
D1 D1
+0.30
301
G.F.L 301
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
-2.60
A
KEY PLAN
SCALE:
-2.20 -2.20 -2.20 0 1m 2m 5m
1:50
SHEET TITLE
M H - 1 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
5
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
REMOVABLE
CLOSE OPENING NOTCH
SPIN IN FLANGED
AT CORNERS WALL
OUTER CONE DUCT RING FASTENERS
22GA. (0.85mm) BLADE 18GA. (1.31mm) BLADE MIN
1/8" (3.2mm) CLEARANCE 1/8" (3mm) CLEARANCE UNED DUCT CONNECTION 45° DEGREE ENTRY 045° EXPOSED TEE SPLINE
DUCT
F2
ALL AROUND UP TO 18" ALL AROUND -19" (483mm) (NO EXPOSED LINER EDGES) REGISTER REGISTER
(457 mm) TO 48" (1219mm) OR GRILLE DUCT OR GRILLE
OPENING CUT COLLAR
FIG. A FIG. B ACCURATELY (SHAPE & SIZE) CEILING
NOTES:-
1-BRACKETS ARE SIZED FOR 3.66 OF DUCT MAXIMUM
2-LOCATE DUCTS AGAINST WALL OR MAXIMUM OF 50 AWAY FROM WALL CONCRETE ANCHORS
3-EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING CRITERIA UNLESS
C MINMUM A B
OTHER ANAL YSIS IS MADE:-
FLANGE
ANCHOR MIN. SPACING MINIMUM
ACOUSTICAL DUCT A-TENSILE LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" DIAMETER CENTER TO EDGE REMARKS
A LINER TO BE THE FULL SHEET METAL
DUCT SHEET METAL B-SHEAR LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" MM (INCHES) CENTER DISTANCE
LENGTH OF THE DUCT DUCT
SECTION WITHOUT JOINTS METAL BORDER
INSULATION EXCEPT AS SHOWN
B 9.5 (3/8") 114.3 (41/2") 57.15 (21/4") USE FOR PIPING THRU
50 mm (2")
C-SECTION 100 m.m. SECTION-A
GALVANIZED DUCT USE FOR PIPING
Y 65-100 MM (21/2"-4")
section A-A
Y 12.7 (11/2") 152 (6") 76.2 (3")
AND ALL DUCTWORK
x X
JOINT
Y Y USE FOR ALL
19 (3/4") 228.6 (9") 114.3 (41/2") EQUIPMENT
DRIVE SLIP STANDING DRIVE SLIP DRIVE SLIP-REINFORCED STANDING S
T-1 T-2 T-3 T-10 JOINT
(SEE DETAIL B)
DETAIL-B
FRAME
DUCT SECTION
RIVET GASKET INSIDE ACOUSTICAL
DUCT LINER
FIG. A
DUCT TRANSVERSE JOINTS RISER SUPPORTS BRANCH DUCT SECTIONS SUPPORTS FROM WALL DETAIL ANCHOR DETAIL
DUCT
DOOR THICK DOOR
WALL SQUARE SECTION SIZE
50 x 50
BLACK STEEL PAINTED STAINLESS STEEL
SCREW
3 m.m
FROM 2 5cm
DUCT
SQUARE SECTION 0 07-2021 FOR TENDER DOCUMENT
#24 GAUGE ALUMINUM 50 x 50
THAN 600 m.m
NOTE:
1. ALL FABRICATED STEEL SHALL BE PAINTED WITH TWO COATS OF ZINC CHROMATE.
DUCT INSULATION DUCTWORK SUPPORT DETAIL ,WALL SUPPORT DUCTWORK SUPPORT DETAIL ,TRAPEZE SUPPORT DUCTWORK SUPPORT DETAIL OUTDOOR AIR LOUVER AND SCREEN
M H - 5 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
WIRE MESH SCREEN WIRE MESH SCREEN WIRE MESH SCREEN C:\Users\Nabil\Desktop\logo.png
AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW
0
E.A.D 34"X10" E.A.D 34"X10" E.A.D 34"X10"
AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW AT LEVEL ABOVE WINDOW
1
-
F4 F4 F4
H
M
MAIN COSULTANT
EX.G 30"X24" EX.G 30"X24" EX.G 30"X24"
AT LEVEL -2.2M AT LEVEL -2.2M AT LEVEL -2.2M
-2.20 -2.20 -2.20 -2.20 64, MOSADAK St. DOKKI, GIZA, EGYPT
TEL:202 33357394 - 202 33372502 FAX: 202 37606556
www.cegman.com
D1 PROJECT
D1
ID-PICO-001
SAND TRAP LOUVER
72"X72" AT 0.5 ABOVE FLOOR
+0.30
G.F.L
A
301 301
18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
-2.60
KEY PLAN
SCALE:
0 1m 2m 5m
1:50
SHEET TITLE
M H - 1 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
1
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
REMOVABLE
CLOSE OPENING NOTCH
SPIN IN FLANGED
AT CORNERS WALL
OUTER CONE DUCT RING FASTENERS
22GA. (0.85mm) BLADE 18GA. (1.31mm) BLADE MIN
1/8" (3.2mm) CLEARANCE 1/8" (3mm) CLEARANCE UNED DUCT CONNECTION 45° DEGREE ENTRY 045° EXPOSED TEE SPLINE
ALL AROUND UP TO 18" ALL AROUND -19" (483mm) (NO EXPOSED LINER EDGES) DUCT
REGISTER REGISTER
(457 mm) TO 48" (1219mm) OR GRILLE DUCT OR GRILLE
OPENING CUT COLLAR
FIG. A FIG. B ACCURATELY (SHAPE & SIZE) CEILING
NOTES:-
1-BRACKETS ARE SIZED FOR 3.66 OF DUCT MAXIMUM KEY PLAN
2-LOCATE DUCTS AGAINST WALL OR MAXIMUM OF 50 AWAY FROM WALL CONCRETE ANCHORS
3-EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING CRITERIA UNLESS
C MINMUM A B
OTHER ANAL YSIS IS MADE:-
FLANGE
ANCHOR MIN. SPACING MINIMUM
ACOUSTICAL DUCT A-TENSILE LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" DIAMETER CENTER TO EDGE REMARKS
A SHEET METAL
LINER TO BE THE FULL SHEET METAL B-SHEAR LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" MM (INCHES) CENTER DISTANCE
DUCT
LENGTH OF THE DUCT DUCT
SECTION WITHOUT JOINTS METAL BORDER
INSULATION EXCEPT AS SHOWN
B 9.5 (3/8") 114.3 (41/2") 57.15 (21/4") USE FOR PIPING THRU
50 mm (2")
C-SECTION 100 m.m. SECTION-A
GALVANIZED DUCT USE FOR PIPING
Y 65-100 MM (21/2"-4")
section A-A
Y 12.7 (11/2") 152 (6") 76.2 (3")
AND ALL DUCTWORK
x X
JOINT
Y Y USE FOR ALL
19 (3/4") 228.6 (9") 114.3 (41/2") EQUIPMENT
DRIVE SLIP STANDING DRIVE SLIP DRIVE SLIP-REINFORCED STANDING S
T-1 T-2 T-3 T-10 JOINT
(SEE DETAIL B)
DETAIL-B
FRAME
DUCT SECTION
RIVET GASKET INSIDE ACOUSTICAL
DUCT LINER
FIG. A
DUCT TRANSVERSE JOINTS RISER SUPPORTS BRANCH DUCT SECTIONS SUPPORTS FROM WALL DETAIL ANCHOR DETAIL
SCALE:
0 1m 2m 5m
DUCT 1:50
DOOR THICK DOOR
WALL SQUARE SECTION SIZE
50 x 50
BLACK STEEL PAINTED STAINLESS STEEL
SCREW
3 m.m
FROM 2 5cm
SQUARE SECTION
DUCT 50 x 50
#24 GAUGE ALUMINUM
THAN 600 m.m
NOMINAL HEIGHT
AREA PACKER IRON ANGLE LOCKING NUT SUPPORT NAIL
CROSS BRACING ANGLE
TYPICAL MASONRY
#18 GAUGE TIE WIRE SUPPORT NUT 50 x 50 x 5 m.m
51 X 51 X 102MM U.S.G. #20 EXPANSION BOLT
SPACED AT 305MM GALVANIZED SHEET METAL
CORNER BEADING
WALL SUPPORT
STEEL ANCHOR 6 m.m SIZE
COMPLETE WITH STEEL NUT WOODEN BEARING PROJECT NO: ID-PICO-001 GN - PLC - 001
SHEET TITLE
M H - 5 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
1
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
D1 D1
+0.70 +0.70
+0.30
G.F.L
20.0000
0 1m 2m 5m
1:50
DATE DESCRIPTION
SHEET TITLE
M H - 1 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
1
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
REMOVABLE
CLOSE OPENING NOTCH
SPIN IN FLANGED
AT CORNERS WALL
OUTER CONE DUCT RING FASTENERS
22GA. (0.85mm) BLADE 18GA. (1.31mm) BLADE MIN
1/8" (3.2mm) CLEARANCE 1/8" (3mm) CLEARANCE UNED DUCT CONNECTION 45° DEGREE ENTRY 045° EXPOSED TEE SPLINE
ALL AROUND UP TO 18" ALL AROUND -19" (483mm) (NO EXPOSED LINER EDGES) DUCT
REGISTER REGISTER
(457 mm) TO 48" (1219mm) OR GRILLE DUCT OR GRILLE
OPENING CUT COLLAR
FIG. A FIG. B ACCURATELY (SHAPE & SIZE) CEILING
VOLUME DAMPER SINGLE BLADE TYPE BRANCH CONNECTIONS RECTANGULAR DUCT BRANCH CONNECTIONS ROUND DUCT CEILING DIFFUSER INSTALLATION DETAIL GRILL AND REGISTER CONNECTIONS
NOTES:-
1-BRACKETS ARE SIZED FOR 3.66 OF DUCT MAXIMUM KEY PLAN
2-LOCATE DUCTS AGAINST WALL OR MAXIMUM OF 50 AWAY FROM WALL CONCRETE ANCHORS
3-EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING CRITERIA UNLESS
C MINMUM A B
OTHER ANAL YSIS IS MADE:-
FLANGE
ANCHOR MIN. SPACING MINIMUM
ACOUSTICAL DUCT A-TENSILE LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" DIAMETER CENTER TO EDGE REMARKS
A SHEET METAL
LINER TO BE THE FULL SHEET METAL B-SHEAR LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" MM (INCHES) CENTER DISTANCE
DUCT
LENGTH OF THE DUCT DUCT
SECTION WITHOUT JOINTS METAL BORDER
INSULATION EXCEPT AS SHOWN
B 9.5 (3/8") 114.3 (41/2") 57.15 (21/4") USE FOR PIPING THRU
50 mm (2")
C-SECTION 100 m.m. SECTION-A
GALVANIZED DUCT USE FOR PIPING
Y Y 12.7 (11/2") 152 (6") 76.2 (3") 65-100 MM (21/2"-4")
AND ALL DUCTWORK
x X
JOINT
Y Y USE FOR ALL
19 (3/4") 228.6 (9") 114.3 (41/2") EQUIPMENT
DRIVE SLIP STANDING DRIVE SLIP DRIVE SLIP-REINFORCED STANDING S
T-1 T-2 T-3 T-10 JOINT
(SEE DETAIL B)
DETAIL-B
FRAME
DUCT SECTION
RIVET GASKET INSIDE ACOUSTICAL
DUCT LINER
FIG. A
DUCT TRANSVERSE JOINTS RISER SUPPORTS BRANCH DUCT SECTIONS SUPPORTS FROM WALL DETAIL ANCHOR DETAIL
SCALE:
0 1m 2m 5m
DUCT 1:50
DOOR THICK DOOR
WALL SQUARE SECTION SIZE
50 x 50
BLACK STEEL PAINTED STAINLESS STEEL
SCREW
3 m.m
FROM 2 5cm
SQUARE SECTION
DUCT 50 x 50
#24 GAUGE ALUMINUM
THAN 600 m.m
NOMINAL HEIGHT
AREA PACKER IRON ANGLE LOCKING NUT SUPPORT NAIL
CROSS BRACING ANGLE
TYPICAL MASONRY
#18 GAUGE TIE WIRE SUPPORT NUT 50 x 50 x 5 m.m
51 X 51 X 102MM U.S.G. #20 EXPANSION BOLT
SPACED AT 305MM GALVANIZED SHEET METAL
CORNER BEADING
WALL SUPPORT
STEEL ANCHOR 6 m.m SIZE
COMPLETE WITH STEEL NUT WOODEN BEARING PROJECT NO: ID-PICO-001 GN - PLC - 001
SHEET TITLE
M H - 5 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
1
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
+0.70 +0.70
+0.30
G.F.L
0 1m 2m 5m
1:50
DATE DESCRIPTION
SHEET TITLE
M H - 1 0 1 - R 0
SHEET 1 OF 1
0
R
OWNER
-
1
C:\Users\Nabil\Desktop\logo.png
0
1
-
H
M
MAIN COSULTANT
PROJECT
ID-PICO-001
REMOVABLE
CLOSE OPENING NOTCH
SPIN IN FLANGED
AT CORNERS WALL
OUTER CONE DUCT RING FASTENERS
22GA. (0.85mm) BLADE 18GA. (1.31mm) BLADE MIN
1/8" (3.2mm) CLEARANCE 1/8" (3mm) CLEARANCE UNED DUCT CONNECTION 45° DEGREE ENTRY 045° EXPOSED TEE SPLINE
ALL AROUND UP TO 18" ALL AROUND -19" (483mm) (NO EXPOSED LINER EDGES) DUCT
REGISTER REGISTER
(457 mm) TO 48" (1219mm) OR GRILLE DUCT OR GRILLE
OPENING CUT COLLAR
FIG. A FIG. B ACCURATELY (SHAPE & SIZE) CEILING
VOLUME DAMPER SINGLE BLADE TYPE BRANCH CONNECTIONS RECTANGULAR DUCT BRANCH CONNECTIONS ROUND DUCT CEILING DIFFUSER INSTALLATION DETAIL GRILL AND REGISTER CONNECTIONS
NOTES:-
1-BRACKETS ARE SIZED FOR 3.66 OF DUCT MAXIMUM KEY PLAN
2-LOCATE DUCTS AGAINST WALL OR MAXIMUM OF 50 AWAY FROM WALL CONCRETE ANCHORS
3-EACH WALL ANCHOR SHALL SATISFY THE FOLLOWING CRITERIA UNLESS
C MINMUM A B
OTHER ANAL YSIS IS MADE:-
FLANGE
ANCHOR MIN. SPACING MINIMUM
ACOUSTICAL DUCT A-TENSILE LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" DIAMETER CENTER TO EDGE REMARKS
A SHEET METAL
LINER TO BE THE FULL SHEET METAL B-SHEAR LOAD=3/8% DUCT WEIGHT SAFETY FACTOR OF 4" MM (INCHES) CENTER DISTANCE
DUCT
LENGTH OF THE DUCT DUCT
SECTION WITHOUT JOINTS METAL BORDER
INSULATION EXCEPT AS SHOWN
B 9.5 (3/8") 114.3 (41/2") 57.15 (21/4") USE FOR PIPING THRU
50 mm (2")
C-SECTION 100 m.m. SECTION-A
GALVANIZED DUCT USE FOR PIPING
Y Y 12.7 (11/2") 152 (6") 76.2 (3") 65-100 MM (21/2"-4")
AND ALL DUCTWORK
x X
JOINT
Y Y USE FOR ALL
19 (3/4") 228.6 (9") 114.3 (41/2") EQUIPMENT
DRIVE SLIP STANDING DRIVE SLIP DRIVE SLIP-REINFORCED STANDING S
T-1 T-2 T-3 T-10 JOINT
(SEE DETAIL B)
DETAIL-B
FRAME
DUCT SECTION
RIVET GASKET INSIDE ACOUSTICAL
DUCT LINER
FIG. A
DUCT TRANSVERSE JOINTS RISER SUPPORTS BRANCH DUCT SECTIONS SUPPORTS FROM WALL DETAIL ANCHOR DETAIL
SCALE:
0 1m 2m 5m
DUCT 1:50
DOOR THICK DOOR
WALL SQUARE SECTION SIZE
50 x 50
BLACK STEEL PAINTED STAINLESS STEEL
SCREW
3 m.m
FROM 2 5cm
SQUARE SECTION
DUCT 50 x 50
#24 GAUGE ALUMINUM
THAN 600 m.m
NOMINAL HEIGHT
AREA PACKER IRON ANGLE LOCKING NUT SUPPORT NAIL
CROSS BRACING ANGLE
TYPICAL MASONRY
#18 GAUGE TIE WIRE SUPPORT NUT 50 x 50 x 5 m.m
51 X 51 X 102MM U.S.G. #20 EXPANSION BOLT
SPACED AT 305MM GALVANIZED SHEET METAL
CORNER BEADING
WALL SUPPORT
STEEL ANCHOR 6 m.m SIZE
COMPLETE WITH STEEL NUT WOODEN BEARING PROJECT NO: ID-PICO-001 GN - PLC - 001
SHEET TITLE
M H - 5 0 1 - R 0
SHEET 1 OF 1