Masterglenium Sky 8233 v2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MasterGlenium® SKY 8233

High-performance super plasticiser based on PCE (polycarboxylic ether) for concrete

DESCRIPTION superplasticisers. It consists of a carboxylic ether


polymer with long side chains. At the beginning of
MasterGlenium SKY 8233 is an admixture of a the mixing process it initiates the same
new generation based on modified polycarboxylic electrostatic dispersion mechanism as the
ether. The product has been primarily developed traditional superplasticisers, but the side chains
for applications in high performance concrete linked to the polymer backbone generates a steric
where the highest durability and performance is hindrance which greatly stabilises the cement
required. particles' ability to separate and disperse. Steric
MasterGlenium SKY 8233 is free of chloride & hindrance provides a physical barrier (alongside
low alkali. It is compatible with all types of the electrostatic barrier) between the cement
cements. grains. With this process, flowable concrete with
RECOMMENDED USES greatly reduced water content is obtained.

 Production of Rheodynamic concrete


PERFORMANCE TEST DATA
 High performance concrete for durability
 High early and ultimate strength concrete Aspect Reddish brown liquid
 High workability without segregation or bleeding
Relative Density 1.08  0.02 at 25°C
 Precast & Pre-stressed concrete
 Concrete containing pozzolans such as pH >6
microsilica, GGBFS, PFA including high volume Chloride ion content < 0.2%
fly ash concrete
FEATURES AND BENEFITS TEST CERTIFICATION/APPROVALS

 Elimination of vibration and reduced labour  ASTM C494 Type F


cost in placing  EN 934-2 T3.1/3.2
 Marked increase in early & ultimate strengths  IS 9103:1999
 Higher E modulus
 Improved adhesion to reinforcing and stressing  IS 2645:2003
steel DOSAGE
 Better resistance to carbonation and other Optimum dosage of MasterGlenium SKY 8233
aggressive atmospheric conditions
should be determined with trial mixes. As a guide,
 Lower permeability - increased durability a dosage range of 500 ml to 1500ml per 100kg of
 Reduced shrinkage and creep cementitious material is normally recommended.
Because of variations in concrete materials, job
Chemistry and mechanism of action site conditions, and/or applications, dosages
What differentiates MasterGlenium SKY 8233 outside of the recommended range may be
from the traditional superplasticisers is a new, required. In such cases, contact your local BASF
unique mechanism of action that greatly improves representative.
the effectiveness of cement dispersion. Traditional For addition information on MasterGlenium SKY
superplasticisers based on melamine and 8233 admixture or on its use in developing
naphthalene sulphonates are polymers which are concrete mixes with special performance
absorbed by the cement granules. They wrap characteristics, contact your local BASF
around the granules' surface areas at the very representative.
early stage of the concrete mixing process. The
sulphonic groups of the polymer chains increase Effects of over dosage
the negative charge of the cement particle surface A severe over-dosage of MasterGlenium SKY
and disperse these particles by electrical 8233 can result in the following:
repulsion. This electrostatic mechanism causes
 Extension of initial and final set
the cement paste to disperse and has the positive
consequence of requiring less mixing water to  Bleed/segregation of mix
obtain a given concrete workability.
 Increased plastic shrinkage
MasterGlenium SKY 8233 has a different A slight overdosing may not adversely affect the
chemical structure from the traditional ultimate strength of the concrete and can achieve

Page 1 of 3
MasterGlenium® SKY 8233
higher strengths than normal concrete, provided it currently suggested by construction industry
is properly compacted and cured. Due allowance standards and practices.
should be made for the effect of fluid concrete WORKABILITY
pressure on form work, and stripping times should MasterGlenium SKY 8233 ensures that
be monitored. rheoplastic concrete remains workable in excess
In the event of over dosage, consult your local of 45 minutes at +25°C. Workability loss is
BASF representative immediately. dependent on temperature, and on the type of
APPLICATION cement, the nature of aggregates, the method of
transport and initial workability.
MasterGlenium SKY 8233 is a ready-to-use liquid To achieve longer workability period please use
which is dispensed into the concrete together with MasterSet RT 55.
the mixing water. The plasticising effect and water It is strongly recommended that concrete should
reduction are higher if the admixture is added to be properly cured particularly in hot, windy and dry
the damp concrete after 50 to 70% of the mixing climates.
water has been added. The addition of PACKAGING
MasterGlenium SKY 8233 to dry aggregate or
cement is not recommended. Automatic MasterGlenium SKY 8233 is supplied in 20 kg,
dispensers are available. 245 kg drums or in bulk on request.

Thorough mixing is essential and a minimum STORAGE /SHELF LIFE


mixing cycle, after the addition of the MasterGlenium SKY 8233 must be stored where
MasterGlenium SKY 8233, of 60 seconds for temperatures do not drop below +5°C. If product
forced action mixers is recommended. has frozen, thaw at +5°C or above and completely
SUGGESTED SPECIFICATION reconstitute using mild mechanical agitation. Do
not use pressurized air for agitation. Store under
The hyperplasticiser shall be MasterGlenium SKY cover, out of direct sunlight and protect from
8233, high range water reducing, Superplasticiser extremes of temperature.
based on polycarboxylic ether formulation. The
product shall have specific gravity of 1.08 & solid Shelf life is 12 months when stored as above.
contents not less than 32% by weight. The product Failure to comply with the recommended storage
shall comply with ASTM C494 Type F and shall be conditions may result in premature deterioration of
free of lignosulphonates, naphthalene salts and the product or packaging. For specific storage
melamine formaldehyde when subjected to IR advice consult your local BASF representative.
Spectra.
PRECAUTIONS
COMPATIBILITY
As with all chemical products, care should be
MasterGlenium SKY 8233 is compatible with taken during use and storage to avoid contact with
most of the products under the MasterPozzolith & eyes, mouth, skin and foodstuffs (which can also
MasterSet series (formerly known as POZZOLITH) be tainted with vapour until product fully cured or
including MasterSet RT 55. Use MasterMatrix 2 dried). Treat splashes to eyes and skin
(formerly known as Glenium Stream 2) as viscosity immediately. If accidentally ingested, seek
modifying agent in self compacting concrete. It immediate medical attention. Keep away from
must not be used in conjunction with any other children and animals. Reseal containers after use.
admixture unless prior approval is received from Do not reuse containers for storage of consumable
BASF Technical Services Department. item. For further information refer to the material
CORROSIVITY- NON CORROSIVE safety data sheet.
MasterGlenium SKY 8233 admixture will neither
initiate nor promote corrosion of reinforcing steel
embedded in concrete, prestressed concrete or
concrete placed on galvanized steel floor and roof TDS Ref. No. : MasterGlnxxSKY8233/02/0517
systems. Neither calcium chloride nor any calcium
chloride-based ingredients are used in the
manufacture of MasterGlenium SKY 8233
admixture. In all concrete application,
MasterGlenium SKY 8233 admixture will conform
to the most stringent or minimum chloride ion limits

Page 2 of 3
MasterGlenium® SKY 8233

® = registered trademark of a MBCC Group member in many countries of the world


The technical information and application advice given in this Master Builders Solutions publication are based on the
STATEMENT OF present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
RESPONSIBILITY assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
(Disclaimer) accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user
is responsible for checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
NOTE Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.

Master Builders Solutions India Private Limited


Registered office: Plot No D-126,
TTC Industrial Area, MIDC,
Shiravane, Navi Mumbai - 400706,
Maharashtra, India
Tel: +91 8657906776
E-mail: Construction-india@mbcc-group.com
www.master-builders-solutions.com/en-in