In single phase applications, if low voltage is available in any one problem [1and you want your
equipment to work on normal voltage, this circuit will solve you’re the automatic phase changer
was made from electronic components which includes; operational amplifiers, diodes, resistors,
capacitors, Zener diodes, transformers, relays and fuses. Results obtained during the test shows
that, whenever the system senses a higher voltage across the input and then engages the load [2].
There are many designs and prototype systems that can perform almost similar functions like,
single phase change-over switches, two phase automatic transfer switch and three phase
automatic change-over switch, but this prototype is about an automatic phase switchover (phase
selector) which is designed for only three phase A.C input power to single phase output
applications[3].The system is high complexity in “Automatic Voltage Regulator “ using ac
voltage – voltage convertor developed by Steven .M Heeltaps [4]. As statistical analysis were
complicated to achieve in single detection Automatic Phase Shift Method for finding Detection
of Grid Connected Photo Voltaic inverter [5]. The system is basically designed to select between
the three phases at reasonable speed, and also address phase imbalances with respect to loads. In
other words, the switching consideration demonstrates the real and practical situation for mainly
domestic, moderate industrial advanced needs [3
This research work was carried out using many passive and active electronic components. The
design of this project includes the placing of components on Vero boards, soldering and
connection of components, test for continuity of components and devices, programming of
microcontroller, circuit testing and troubleshooting and result analysis. This circuit was first
simulated using Proteus 7 electronic simulation software before constructed and the programmer
was written using MIDE compiler software. A block diagram of the single phase microcontroller
based automatic changeover switching system and a flow chart of the circuit design process is
shown in figure 1 and figure 2, respectively, while a study of each of the units present in
isolation and when connected together is explained in details in the following section. Figure 3
shows the schematic circuit diagram of the single phase microcontroller based automatic
changeover switch that was designed.
C1: This is the filter capacitor (electrolytic) and it comes with a capacitance and a voltage rating.
Voltage Rating
The voltage of the capacitor must be able to withstand 1.5 times the output voltage of the diode.
VDp = Vp - VD
(2)
Where VDp is the output peak voltage from the diodes.
Vp is the peak voltage of the transformer
VD is the voltage drop of the diodes (0.7 x 2)
Therefore 3
VDp = 16.97V – 1.4V
VDp = 15.57V
VC = 1.5 x VDp
Vc is the voltage rating of the capacitor
Vc = 23.6V
Capacitance Rating:
The capacitance of the capacitor must be such that it could reduce the ripple voltage (VR) to
about 30% of the output peak voltage from the diodes.
VR = 30% of VDp
(3)
VR = 4.67V
From the ripple voltage equation, we could get the capacitance
VR =
(4)
Where VR is the ripple voltage Imax is the maximum current from the diodes/transformers
f = the frequency of supply
C = the capacitance of the capacitor in Farads.
From previous calculations,
Imax = 1000mA, f = 50Hz, VR = 4.67V
C = 2.141 x 10-3 F
C = 2141.32 µF
This value cannot be obtained in the market so the next capacitance value is chosen. Therefore
the capacitance to use is 2200µF /35V, though in this work, 3300µF/50V was used as it was the
closest gotten during the time of construction.
Microcontroller Unit
The microcontroller unit circuit is the heart of the project. This is where; the program for the
control part of the project is written and burned using assembly language and a universal
programmer, respectively.
The 8052 microcontroller hardware circuit is usually a very flexible one, and all the surrounding
components are given a recommended range of values, by the datasheet but the actual values can
be chosen by the programmer.
For the programming of the microcontroller for the automatic changeover switching system, the
chosen values are as follows:
• Reset capacitor (C1): 10µF
• Reset resistor (R1): 10 KΩ
• Crystal oscillator (X1): 12MHz
• Crystal capacitors (C2 & C3): 33pF
• Pull-up resistors (R5 to R9): 1 KΩ
Display Unit
This unit shows the status of the system. It serves as an interface between the user and system. It
consists of light emitting diodes (LEDs) and current limiting resistors (6 each). The value of each
current limiting resistor is calculated using the following equation:
Where Rx = current limiting resistor, VS = Supply voltage (5V), VD = Diode voltage (2V) and
ID = diode current
(10mA – 20mA).
NB: The more the current, the brighter the LED; thus, the shorter the lifespan and vice versa.
Therefore,
We have thus used a resistance of 330Ω as the value of current limiting resistor.
The power consumed by one LED is:
P = IV
(6)
P = 10mA x 5V = 0.05VA
Therefore, for 6 LED’s, the power consumed is 6 x 0.05VA = 0.3VA.
(7)
For 50% duty cycle, R2 = 10R1
The DC voltage rating of a buzzer is 3-24V.
Changeover Switch
This is the unit responsible for changeover between PHCN supply and generator power. Since a
contactor has four poles of 25A current each, two poles were looped to get a current of 50A for
the PHCN and generator phase. Thus, the maximum power the contactor can withstand for a
240V a.c supply is:
P = IV
P = 50A x 240V = 12KVA
3.8. Gen/PHCN Supply Monitoring Unit
This circuit monitors the type of power source that is available for use and feeds the
microcontroller for changeover to be effected. It consists of resistors, rectifier diodes, transistor-
based opto-isolator (4N35) and a NOT gate
(CD4069).
When a power source is available, the voltage is rectified and the LED in the transistor-based
opto-isolator is forward biased, therefore putting the transistor in the same IC into saturation. The
NOT gate is connected to microcontroller which take action as implemented by the program. RE
is a pull down resistor varying from 470Ω – 22kΩ.
The LED in 4N35 has a forward diode current of 1mA and RC has a value of 220k (10RE).
The circuit in figure 4 is one that would automatically turn on a generator when
public power supply fails, and automatically change over the source of power
supply to the load to generator power. When public power is restored, it sounds
an alarm for a while to verify if the power is steady, then it changes over back to
public power supply and shuts down the generator. In the event that the
generator refuses to start at the sixth trial, the system shuts down and sounds an
alarm indefinitely until the reset button is pressed or public power is restored. In
the event that the generator refuses to stop, the system sounds an alarm
indefinitely until the reset button is pressed. The function of the LEDs in the
display section of the constructed circuit is given in the table below:
In this research work, the simulation and construction of an efficient and cost
effective single phase microcontroller based automatic changeover switching
system was achieved. This circuit has the ability to accurately monitor the
power supply from the national grid of the Power Holding Company and
respond appropriately upon a power outage by starting a standby generator to
supply power. Upon the restoration of utility power, the system changes the load
back to utility and shuts down the generator.
Due to the looping of the pole of the contactor to give 50A current each for
PHCN and generator, the maximum power the circuit can withstand or an ac
voltage of 240V is 12KVA. This means the circuit can carry a large amount of
power in homes and offices. This project saves resources like time, energy and
even lives while ensuring automatic and efficient power load sharing from the
consumer end. This project does not have any restriction in the aspect of who to
use it and who not to use it nor where to use it and where not to use it. Its
applications range from domestic homes, light industries and heavy industries.
2.2 Components
The research project is designed for power supply applications. It involves automatic change
over between the mains power supply and a standby generating set. The project implements an
automatic switching or starting of the power generator, whenever the main power fails. The
circuit of the project consists of logical control units, display units, alarm units and relay
switches. The design of the project takes into consideration practical or real life situations and a
lot of precautions were put in place to make its performance acceptable, even though it is a
prototype design.
This project, howev is designed and implemented as a micro-processor based controlled
system, specifically using the micro-controller as its basic component. It is a dedicated
embedded system.
The Power supply unit is responsible for supplying the system’s power requirements. It makes
power available to the other units of the hardware system. The Power supply unit delivers 5V dc
regulated supply at 1A each. The paper basically supplies continuous power to a load in
automated mode through one of the four sources of supply that are: solar, mains, thermal, and
wind when any one of them is unavailable.
All power supplies have a power input connection, which receives energy in the form of electric
current from a source, and one or more power output connections that deliver current to the load.
The source power may come from the electric power grid, such as an electrical outlet, energy
storage devices such as batteries or fuel cells, generators or alternators, solar power converters,
or another power supply. The input and output are usually hardwired circuit connections, though
some power supplies employ wireless energy transfer to power their loads without wired
connections. Some power supplies have other types of inputs and outputs as well, for functions
such as external monitoring and control
The microcontroller unit circuit is the heart of the project. This is where; the program for
the control part of the project is written and burned using assembly language and a
universal programmer, respectively.
The 8052 microcontroller hardware circuit is usually a very flexible one, and all the
surrounding components are given a recommended range of values, by the datasheet but
the actual values can be chosen by the programmer.
The control system typically is the 8052 microcontroller and the entire components
needed to properly configure it for proper operations. The output interfaces involves all
the circuit that converts the digital signal from the control system back to it equivalent
analog signal for output devices requiring analog outputs, but it gives digital output to
output devices that require digital outputs. For the programming of the microcontroller
for the automatic changeover switching system, the chosen values are as follows:
This unit shows the status of the system. It serves as an interface between the user and system. It
consists of light emitting diodes (LEDs) and current limiting resistors (6 each).
Liquid crystal display: The liquid crystal display (LCD) is provided to display all the measured
electrical quantities to the connected load; so, making it user friendly. Primarily, the system
monitors the utility power supply and the generator, and connects the available supply to the
loads.
Security alarm
Is a system designed to detect the conditions of the power
Alarm Unit
The alarm sounds on four conditions:
• When power fails
• When power is restored
• If a command is given for generator to start and it refuses after the six trials
• If a command is given for generator to stop and it refuses.
Mostly it installed into a building or other area such as a home or school. Security alarms are
used in residential, commercial, industrial, and military properties for protection
against burglary (theft) or property damage, as well as personal protection against intruders.
Security alarms in residential areas show a correlation with decreased theft.[1] Car
alarms likewise help protect vehicles and their contents. Prisons also use security systems for
control of inmates.
There are two alarms, one sounds when there is utility power restoration (in the beginning of the
circuit when you turn it ON, when power goes out and when power comes back) and the other
alarm is called an error alarm sounds when the system deviates from its usual or defined pattern
e.g. when the generator refuses to start or stop. The alarm circuit comprises audio (buzzer) BUZ1
and visual (LED) D3 indicators driven by a 555 timer U6 connected in a stable mode. In this
mode it has no stable state. The 555timer produces a square wave (pulsating or intermittent
signal) and its output continually switches state between high and low without any intervention
from the user. As stated already, when there is the presence of power from the mains supply, the
NOT gate D5A sends a low signal to the microcontroller U3 which will in turn send a low signal
to the 555 timer (U6) connected in an a stable mode, which produces a signal of alternating
pulses with a 50% duty cycle, which triggers the buzzer to output a constant pulsating alarm and
flashes the LED D3 on and off.
2.3 Applications
Power outages can occur, even in high reliability distribution networks, leading to major
incidents and losses on critical applications.
To maximize your power availibility, the Socomec range will safely transfer from any unstable
or lost source to an alternate source. Additionally, we ensure that you are prepared at all times
thanks to our unique safety functions that facilitate maintenance on your low voltage electrical
installation.
Buildings
Cooling or heating systems, lights, lifts, servers or security systems are always working thanks to
a transfer switch that will automatically switch to an available power source. Users, visitors and
staff have one less thing to worry about.
High-rise buildings
Commercial malls
Public spots
Offices & Hotels
Small business
Healthcare
When talking about lives of patients we can’t take the risk. Ensuring power supply in all spaces
of a medical center makes patients, visitors and staff feel safe and comfortable.
Group 2 installations
Imaging
Room’s area
Pre-born
Infrastructure
Some infrastructure activities have no rest. Travellers and workers need 24/7 available facilities
and if weather, a natural disaster or any unpredicted utility outgage occurs, you need a reliable
transfer system to an emergency source.
Airports
Harbours
Tunnels
Highways
Industry
Long lasting and reliability solutions for harsh environments, extreme conditions and continuous
operations. Keep your productivity, your delivery times and your staff always safe.
24/7 processes
Supply chains
Machiniery
Control room
In general the applications of the systems is
i. Hostels and Hotels
ii. Hospitals
iii. Colleges
iv. Offices
v. Industries
The power over switching mechanism is vastly depending on the type of load transfer switches that have
been installed with your system. Many establishments continue to ponder over the pros and cons of the
two main types of load transfer switches – Manual and automatic. While the manual switches need to
be triggered by a personnel of the establishment, the Automatic Transfer Switch is triggered seamlessly
at any indication of blackouts. Here is a look at the three major pros and cons of the automatic versions
of load transfer switches.
Advantages Disadvantages
There is a higher margin of error for many
More automatic operation with the establishments.
elimination of selector switch
Reduced circuit size and easier The automatic switches will also need a more
implementation technical and elaborate maintenance routine as
compared to the manual switches.
Highly sensitive