Valve amplifier for proportional valves

without electrical position feedback

Type VT-MSPA
RE 30232-Z
Supplementary information Edition: 2018-06

▶▶ Component series 2X

HAD8134

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


2/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

Content

VT-MSPA1 / VT-MSPA2 4
VT11118-1X 7
VT2000-5X 9
VT3000-3X 11
VT3006-3X 13
VT11132-1X 15
VT-MSPA1-1-1X/V0/0, VT-MSPA1-10-1X/V0/0, VT-MS-
PA1-11-1X/V0/0 16
VT-MSPA1-150-1X/V0/0, VT-MSPA1-30-1X/V0/0 17
VT-MSPA1-50-1X/V0 18
VT-MSPA2-1-1X/V0/0 19
VT-MSPA2-525-10/V0 21
VT-MSRA1-1-1X/V0/0 23
VT-VSPA1-11-1X/V0/0, VT-VSPA1-10-1X/V0/0 25
VT-VSPA1-11-1X/V0/0, VT-VSPA1-10-1X/V0/0 26
VT-VSPA1-1-1X, VT-VSPA1K-1-1X/ 27
VT-VSPA1-2-1X/V0/0, VT-VSPA1-2-1X/V0/A4 30
VT-VSPA1-2-1X/V0/0, VT-VSPA1-2-1X/V0/A4 31
VT-VSPA2-1-1X/T1, VT-VSPA2-1-1X/T5 32
VT-VSPA2-1-2X/V0/T1, VT-VSPA2-1-2X/T5 35
VT-VSPA2-1-2X/V0/T1, VT-VSPA2-1-2X/T5 36
VT-VSPA2-50-1X/T1, VT-VSPA2-50-1X/T5 39
VT-SWMA-1-1X/V0/0 42

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 3/48

This supplementary information is to assist users in changing over to or replacing old amplifiers by the VT-MSPAx-2X.
It contains rewiring tables and draws your attention to the differences between the devices.

= Terminal number and function identical

⇒ Identical function with other terminal number ⇒ rewiring

x Function not compatible

* Parameter variant of digital input

** Changed scaling

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


4/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-MSPA1 / VT-MSPA2

1 2 3 4 1 2 3 4
5 6 7 8 5 6 7 8

DI DI
t t
Z/B Z/B
G G
S S

Set Set

9 0 1 9 0 1 9 0 1 9 0 1
8 2 8 2 8 2 8 2
7 3 7 3 7 3 7 3
6 5 4 6 5 4 6 5 4 6 5 4
valve valve
I IB IA
T T
v v

MSPA2
MSPA1

9 10 11 12 9 10 11 12

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Supply
voltage 1
1
+24V +U
XH1 U M0
U -U
0V Enable
2
Ready 15 KBA
Block circuit diagram VT-MSPA1

☺6 KBB

Digital input 5 13
DI t 11
t t

Logic
XH2 IB
t t 8 KBB
Cable break

Comm. value 9 2 6 x
+In
Enable

U(I) yG B G 10
X2A 12 3
U 14
b

-In S PWM U XH1


10 B PID U
4
9
t t
t
Zw ∑ -1
t t
4 3 5
7
Actual value 11
+Out
U V Test jack
IA- IB U
X2A U
U
-Out
12

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 5/48
6/48

Supply
voltage 1
1
+24V 9
+U
U 7
XH1 M0 G
A U
PWM XH2
U -U PID U
0V Enable
a

S 12 8
2 10
Ready 15 B
KBA
Enable

☺6 KBA Cable break


Block circuit diagram VT-MSPA2

KBB

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Digital input 5 13
IA
DI t 11
t t

Logic
XH2 IB
t t 8 KBB
Cable break
Comm. value 9 6 x
2
Enable

+In B G 10
b

U(I) yG
X2A 12
3
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

U 14
-In S PWM U XH1
10 B PID U
4
9
t t
t
Zw ∑ -1
t t
4 3 5
7
11
+Out
U V Test jack
IA- IB U
X2A U
U
-Out
Actual value 12
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 7/48

VT11118-1X

VT11118-1X VT-MSPA2-2X

+UB / 24 VDC 1 = 1 +UB / 24 VDC


0V 2 = 2 0V
Enable 1 3 ⇒ 5 DI enable
Command value U +/- 4 ⇒ 9 Command value +
Reference potential 5 ⇒ 10 Command value -
Enable 2 6 x 6 DO ready
Solenoid A 7 ⇒ 7 Solenoid A +
Solenoid A 8 ⇒ 8 Solenoid A -
Solenoid B 9 ⇒ 3 Solenoid B +
Solenoid B 10 ⇒ 4 Solenoid B -
n. c. 11 x 11 AO: I - act +
n. c. 12 x 12 AO: I - act -

As against VT11118, the VT-MSPA2-2X is provided with only one enable input and one command value attenuator.
With the VT-MSPA2-2X, command value inversion is a possible function of the digital input.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


8/48

    

   
  Solenoid a
 
  
Operating
 
VT11118-1X (RE 30218)

 
voltage 
Block circuit diagram





 
  Solenoid b


Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


 

Differential input
Command value  

±10 V   


Reference  
potential
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

 

Enable 1  


Enable 1


Enable 2

GW1 = Comm. value attenuator 1


1 Power supply unit 7 Short-circuit detector
GW1 = Comm. value attenuator 2
2 Differential amplifier 8 Clock pulse generator
t = Ramp time setting
3 Ramp generator 9 Current controller
s = Step-change height at Ucomm
4 Step function generator 10 Output stage
= ±10 V
5 Summator 11 Current measurement of solenoids
H1 = Enable logic mode 1
6 Comm. value changeover 12 Overcurrent detector
H2 = Enable logic mode 2
and enable of utput stages
13 Valve type selector switch
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 9/48

VT2000-5X

VT2000-5X VT-MSPA1-2X

Ramp “up” off


2ac ⇒ 5* Ramp off
Ramp “down” off
Pot. for ramp signal 4ac - -
5 Enable
Grounding 6ac x
6 Ready
Grounding 8ac - -
+9 V 10ac - -
Command value 1 +9 V 12ac - -
M0 14ac - - Gw
Command value 1 -9 V 16ac - -
0V 18ac ⇒ 2 0V
Solenoid - 20ac ⇒ 4 Solenoid - t
Solenoid + 22ac ⇒ 3 Solenoid +
+UB /24 VDC 24ac ⇒ 1 +UB /24 VDC
Iact 26a ⇒ 11 Act out + t
n. c. 26c x 12 Act out -
w
n. c. 28a x - -
I
Differential input, com-
mand value 2 +10 V
28c ⇒ 9 +In M0
Differential input, reference
30ac ⇒ 10 -In
VT2000
potential / GND
Command value 0 - 6 V 32ac - -

Switching the ramps off separately as provided by the VT2000 is not possible with the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


10/48

Ramp “up” off 2a

Ramp “down” off 2c


4ac
32ac Comm. value
0 to 6 V
VT2000-5X (RE 29904)

28c 14ac
Differential Comm. value 2 +10 V u
Block circuit diagram

Reference 30ac 4
input u Σ
potential/GND Gw
100 Hz / 200 Hz
1
2 S2 (frequency)
3
12ac
Comm. value 1 +9V 7

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


6ac S1
t t (t ramp) 6 22ac
8ac
Zw u
10ac (R130) Σ i 20ac
+9V
14ac 9
M0 5
16ac
-9V
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

24ac 2,5 AT
+ 24 V
Operating voltage + =
0V⊥ 18ac
26a Act. current value
2 x 220 µF
8 1 mV ≙ 1 mA

GW = Command value attenuation


1 Differential input 7 Clock pulse generator
t = Ramp time setting
2 Summator 8 Power supply unit
Zw (R130) = Additional biasing current setting
3 Attenuator, max. command 9 Proportional solenoid of the
(0 to 300 mA)
value valve
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 11/48

VT3000-3X

VT3000-3X VT-MSPA2-2X

Auxiliary voltage +/-9 V 2a -


- 2c
Comm. value call-up 2 4c
Call-up of “switch auxiliary
4c ⇒ 5* Inversion
voltage over”
Comm. value call-up 3 6a x 5 Enable
Comm. value call-up 4 6c - Rexroth

Command value 3 +/-9 V 8a - H11


H12
Comm. value call-up 1 8c -
w1
Command value 2 +/-9 V 10a - H1
w2
Command value 1 +/-9 V 10c - H2
w3
Command value 4 +9 V 12a x 11 Act out + H3
Command value 5 +6 V 12c x 12 Act out - w4
H4
External ramp (pos. comm. 14a x -
t
value = solenoid B / neg.
14c x - W 0 ... ± 6 V
comm. value = solenoid A) IB mV = mA
IA mV = mA
Differential input, com-
16a ⇒ 9 +In
mand value 6 +/-10 V
Differential input, reference VT 30XX
16c ⇒ 10 -In
potential
Command value after ramp 18a -
Call-up “ramp off” 18c ⇒ 5* Ramp off
M0 (is raised by 9 V as
20a -
against 0 V operating voltage)
+9 V 20c -
Solenoid B + 22a ⇒ 3 Solenoid B +
n. c. 22c -
Solenoid A - 24a ⇒ 8 Solenoid A -
n. c. 24c -
Operating voltage 0 V 26a ⇒ 2 0V
-9 V 26c -
Solenoid B - 28a ⇒ 4 Solenoid B -
Relay call-up voltage
28c x -
(+24 V)
Solenoid A + 30a ⇒ 7 Solenoid A +
n. c. 30c -
32a
Operating voltage +UB ⇒ 1 +UB / 24 VDC
32c

The VT-MSPA2-2X does not feature command value call-ups. If these are required, they have to be implemented by means
of command value module VT-SWMA-1-1X. An external analog ramp time command value is not available in the VT-MS-
PA2-2X. The functions “Inversion“ and “Ramp off“ are not available together in the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Positive comm. value
controls solenoid “B“
12/48

Negative comm. value


X1 Current comm. value at “W” X1
controls solenoid “A“
14c 0 to +6 V for solenoid “A”
14a 0 to -6 V for solenoid “B” 8
Ramp external
12c
Command value 5 ±6 V Act. current value IA at “IA“ Biasing current
12a Act. current value IB at “IB“ F of solenoid “A”
Command value 4 ±9 V W
VT3000-3X (RE 29935)

8a 7
Command value 3 ±9 V F 30a
Block circuit diagram

10a F IA 7
Command value 2 ±9 V t u
10c –1 i 24a
Command value 1 ±9 V F F F F Σ
w1 w2 w3 w4 5 Solenoid “A”
K5

3 4 6

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


F
1 Σ IB
K4.1 Σ
K3.1 J5, J6
K1.1 K2.1
2 22a
Comm. value 16a F
Differential u 9 i
6 +10 V 16c H12 u 28a
input Reference u Σ
7 Solenoid “B”
potential
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

7
– Biasing current of
2a K6
Command value 1 ±9 V solenoid “B” 18a Command value
+
10 after ramp
20c 32a
Measurement zero (M0) +9 V =
20a F 32c +UB
raised by 9 V as against M0 H11 2,5 A T
26c Operating
0 V operating voltage –9 V F voltage
8c K1 1 H1 26a
Comm. value call-up 1 0V
4a K2 H2 F
Comm. value call-up 2
6a K3 H3 F 1 Command values
Comm. value call-up 3
6c K4 H4 F
Comm. value call-up 4 2 Differential input
18c K5
Call-up “ramp off” 3; 6 Summator F = on front panel
Call-up “switch aux. voltage over” 4c K6
28c 4 Ramp generator
Relay call-up voltage(+24 V)
5 Step function generator
7 Current output stage
H1 to H4 = Indication of command K1 to K6 = Call-up relay
value call-ups 8 Clock pulse generator
H11 = “Power on“ w1 to w4 = Command values 9 Monitoring functions
H12 = “Ready for operation” t = Ramp times 10 Power supply unit
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 13/48

VT3006-3X

VT3006-3X VT-MSPA2-2X

Auxiliary voltage +/-9 V 2a -


- 2c
Comm. value call-up 2 4a
Call-up of “switch auxiliary
4c ⇒ 5* Inversion
voltage over”
Comm. value call-up 3 6a x 5 Enable Rexroth
Comm. value call-up 4 6c -
Command value 3 +/-9 V 8a - H11
H12
Comm. value call-up 1 8c -
w1 t1
Command value 2 +/-9 V 10a - H1
Command value 1 +/-9 V 10c - w2 t2
H2
Command value 4 +9 V 12a x 11 Act out + w3 t3
Command value 5 +6 V 12c x 12 Act out - H3
w4 t4
External ramp (pos. comm. 14a - H4
value = solenoid B / neg. t5
14c -
comm. value = solenoid A)
W 0 ... ± 6 V
Differential input, com- IB mV = mA
16a ⇒ 9 +In
mand value 6 +/-10 V IA mV = mA
Differential input, reference
16c ⇒ 10 -In
potential
VT 30XX
Command value after ramp 18a -
Call-up “ramp off” 18c ⇒ 5* Ramp off

M0 (is raised by 9 V as
against 0 V operating volt- 20a -
age)

+9 V 20c -
Solenoid B + 22a ⇒ 3 Solenoid B +
n. c. 22c -
Solenoid A - 24a ⇒ 8 Solenoid A -
n. c. 24c -
Operating voltage 0 V 26a ⇒ 2 0V
-9 V 26c -
Solenoid B - 28a ⇒ 4 Solenoid B -
Relay call-up voltage
28c -
(+24 V)
Solenoid A + 30a ⇒ 7 Solenoid A +
n. c. 30c -
32a
Operating voltage +UB ⇒ 1 +UB / 24 VDC
32c

The VT-MSPA2-2X does not feature command value call-ups and ramp call-ups. If these are required, they have to be
implemented by means of command value module VT-SWMA-1-1X. An external analog ramp time command value is not
available in the VT-MSPA2-2X. The functions “Inversion“ and “Ramp off“ are not available together in the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Positive comm. value
controls solenoid “B“
14/48

X1 Current comm. value at “W” X1


Negative comm. value K1.2 K2.2
K3.2 0 to +6 V for solenoid “A”
controls solenoid “A“ K4.2
14c 0 to -6 V for solenoid “B”
F F F F F
t5 t1 t2 t3 t4 Act. current value IA at “IA“ 8
Ramp external 14a
Actual current value IB at “IB“ Biasing current
12c F
Command value 5 ±6 V W of solenoid “A”
12a
VT3006-3X (RE 29926)

Command value 4 ±9 V 7
8a F 30a
Command value 3 ±9 V 7
Block circuit diagram

IA
10a u
Command value 2 ±9 V i 24a
10c –1
Command value 1 ±9 V F F F F Σ Solenoid “A”
w1 w2 w3 w4 5
K5

3 4 6
F

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


1 Σ IB
K4.1 Σ
K3.1 J5, J6
K1.1 K2.1

Comm.value 2 22a
16a F
Differential 6 +10 V u 9 i
16c H12 u 28a
input Reference u Σ
potential Solenoid “B”
7
7
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

– Biasing current
2a K6
Auxiliary voltage ±9 V of solenoid “B” 18a Comm. value
+
10 after ramp
32a
Measurement zero (M0) +9 V 20c =
raised by 9 V as against M0 20a F 32c +UB
H11 2,5 A T
26c Operating
0 V operating voltage –9 V
1 F voltage
8c K1 H1 26a
Comm. value call-up 1 0V
4a K2 H2 F
Comm. value call-up 2
6a K3 H3 F
Comm. value call-up 3
6c K4 H4 F 1 Command values
Comm. value call-up 4
18c K5 2 Differential input
Call-up “ramp off”
Call-up “switch aux. voltage over” 4c K6
3; 6 Summator F = on front panel
Relay call-up voltage 28c
(+24 V) 4 Ramp generator
5 Step function generator
7 Current output stage
H1 to H4 = Indication of command K1 to K6 = Call-up relay
value call-ups 8 Clock pulse generator
H11 = “Power on“ w1 to w4 = Command values 9 Monitoring functions
H12 = “Ready for operation” t1 to t5 = Ramp times 10 Power supply unit
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 15/48

VT11132-1X

VT11132-1X VT-MSPA1-2X

+UB / 24 VDC 1 = 1 +UB / 24 VDC


4 5 6
0V 2 = 2 0V
Reference potential GND 3 ⇒ 10 Command value -
REXROTH
Solenoid 1 4 ⇒ 3 Solenoid + VT 11131
Solenoid 2 5 ⇒ 4 Solenoid -
R11
Command value +
Signal 0-10 V 6 ⇒ 9 R12
0...10 V
5 DI enable
R1
6 DO ready
H3
7 -
R2
8 -
11 AO: I - act +
12 AO: I - act -
1 2 3

Block circuit diagram

VT11132-1X (RE 29865)

+UB
R11 R12 R2
Differential input: 7
Ucomm: 0 to +10 V 6 u 4
Reference potential/ 3
u
GND
2 3 4 5
R1
H3 9
5
+UB
8

DC +
1
+ UB
Operating
DC –
voltage 1
2
0V

1 = Power supply unit 6 = Clock pulse generator


2 = Differential amplifier 7 = Output stage
3 = Ramp generator 8 = Switching stage
4 = Function generator 9 = Proportional solenoid
5 = Current controller

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


16/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-MSPA1-1-1X/V0/0, VT-MSPA1-10-1X/V0/0, VT-MSPA1-11-1X/V0/0

VT-MSPA1-1-1X/V0/0 VT-MSPA1-2X
VT-MSPA1-10-1X/V0/0
VT-MSPA1-11-1X/V0/0
4 5 6
+UB / 24 VDC 1 = 1 +UB / 24 VDC
0V 2 = 2 0V Rexroth
-Ucomm 3 ⇒ 10 Command value - VT-MSPA1-1
Solenoid + 4 ⇒ 3 Solenoid +
Solenoid - 5 ⇒ 4 Solenoid -
Command value + Gw
+Ucomm 6 ⇒ 9 Zw
0...10 V
5 DI enable t<
6 DO ready t>
7 -
8 - w I
11 AO: I - act +
12 AO: I - act -
1 2 3

Block circuit diagram

VT-MSPA1-1-1X/V0/0, VT-MSPA1-10-1X/V0/0, VT-MSPA1-11-1X/V0/0 (RE 30223)

+UB 1 4
24 V 14
1 11 P
3
2 DC
T

0V DC 13
2 12 5

15 Power

6 7 8 I>
Zw F t< F t> F
GND 3
10
U 9
16
Gw W i
U
Command value
F
0...+10 V 6 4 5

1 = Fuse 6 = Pot. for zero point 12 = Clock pulse generator


2 = Suppressor diode 7 = Pot.“ramp up” 13 = Schmitt trigger
3 = Power supply unit 8 = Pot. “ramp down” 14 = Output stage
4 = Command value input 9 = Potentiometer Imax 15 = Fault detection
5 = Ramp generator 10 = Characteristic curve generator 16 = Test jack
11 = Current controller F = on front panel

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 17/48

VT-MSPA1-150-1X/V0/0, VT-MSPA1-30-1X/V0/0

VT-MSPA1-150-1X/V0/0 VT-MSPA1-2X
VT-MSPA1-30-1X/V0/0
4 5 6

+UB / 24 VDC 1 = 1 +UB / 24 VDC


Rexroth
0V 2 = 2 0V
VT-MSPA1-1
-Ucomm 3 ⇒ 10 Command value -
Solenoid B 4 ⇒ 3 Solenoid +
Solenoid B 5 ⇒ 4 Solenoid - Gw
Command value + Zw
+Ucomm 6 ⇒ 9
0...10 V t<
7 x 5 DI enable t>
8 x 6 DO ready
9 x 7 - w I
10 x 8 -
11 x 11 AO: I - act +
12 x 12 AO: I - act +
1 2 3

Block circuit diagram

VT-MSPA1-150-1X/V0/0, VT-MSPA1-30-1X/V0/0 (RE 30224)

+UB 1 4
24 V 14
1 11 P
3
2 DC
T

0V DC 13
2 12 5

15 Power

6 7 8 I>
Zw F t< F t> F
GND 3
10
U 9
16
Gw W i
U
Command value F
0...+10 V 6 4 5

1 = Fuse 6 = Pot. for zero point 12 = Clock pulse generator


2 = Suppressor diode 7 = Potentiometer “ramp up” 13 = Schmitt trigger
3 = Power supply unit 8 = Pot. “ramp down” 14 = Output stage
4 = Command value input 9 = Potentiometer Imax 15 = Fault detection
5 = Ramp generator 10 = Characteristic curve generator 16 = Test jack
11 = Current controller F = on front panel

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


18/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-MSPA1-50-1X/V0

VT-MSPA1-50-1X/V0 VT-MSPA1-2X

+UB / 24 VDC 1 = 1 +UB / 24 VDC


0V 2 = 2 0V
Reference potential GND 3 ⇒ 10 Command value - Rexroth
VT-MSPA1-50
Solenoid 4 ⇒ 3 Solenoid +
Solenoid 5 ⇒ 4 Solenoid -
Command value +
Command value 0...10 V 6 ⇒ 9
0...10 V
5 DI enable
6 DO ready
7 -
8 -
11 AO: I - act +
12 AO: I - act +

Block circuit diagram

VT-MSPA1-50-1X/V0 (RE 30225)

Differential input (Ucomm) t< Sw UB I


2 3 4 5 w 7
Comm.value: 0 to 10 V 6 4
u u
Reference potential/ 3 u  i 5

GND 9
Zw t> Gw 6
=

&
8
UB

1
Operating +UB DC
voltage 0 V 2 DC
1

1 = Power supply unit Zw = Zero point, command value


2 = Differential amplifier t< = Ramp time “up”
3 = Command value summator t> = Ramp time “down”
4 = Ramp generator Sw = Step height
5 = Characteristic curve generator Gw = Max. command value
6 = Clock pulse generator w = Command value
7 = Current output stage I = Actual current value
8 = Fault detection
9 = Proportional valve

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 19/48

VT-MSPA2-1-1X/V0/0

VT-MSPA2-1-1X/V0/0 VT-MSPA2-2X

+UB / 24 VDC 1 = 1 +UB / 24 VDC


0V 2 = 2 0V 7 8 9 10 11 12
DI enable 3 ⇒ 5* DI enable
Rexroth Gw+
Command value VT-MSPA2-1
4 ⇒ 10 Command value -
IN - Gw-
Command value Command value + Sw+
5 ⇒ 9
IN + 0...10 V Sw-
f
Inversion 6 ⇒ 5* Inversion Zw
Solenoid B - 7 ⇒ 3 Solenoid B - t<
1
Solenoid B + 8 ⇒ 4 Solenoid B + 2 t>
Solenoid A + 9 ⇒ 7 Solenoid A + 3 t<t>
Solenoid A - 10 ⇒ 8 Solenoid A - I w
⊥ wR
n. c. 11 x 11 AO: I - act +
n. c. 12 x 12 AO: I - act +
1 2 3 4 5 6
6 DO ready

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


20/48

b
t> t< wR M0 w
(8)
t> t< (7) 7
(4) U 8
(2) (3) 9
β t
5 U I 10
>50k α δ
IN+ γ
Comm. value ±10 V 4 Σ I
Block circuit diagram

>50k U ok
IN- ok (5) a
VT-MSPA2-1-1X/V0/0 (RE 30228)

Gw+ Gw- S
(6) 1
(9)
Zw 2
3

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Sw+ Sw- Σ
(12)
6
Inversion -1
f
ok
(10)
3
Enable &
(1)
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

UL
1 (11)
+15V
24 V DC +10V
M0
2 –10V
0V L0 100 µF
DC
–15V

Zw = Zero point, command value


1 Power supply unit 7 Current controller
t< = Ramp time “up”
2 Differential amplifier 8 Current output stage
t> = Ramp time “down”
3 Comm. value summator 9 Clock pulse generator
Sw = Step height
4 Ramp generator 10 Enable function
Gw = Amplitude attenuator
5 Char. curve generator 11 Fault detection
w = Command value
6 Amplitude limiter 12 Inversion
wR = Comm. value after ramp
= Ready for operation
= Enable
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 21/48

VT-MSPA2-525-10/V0

VT-MSPA2-525-10/V0 VT-MSPA2-2X

0 V signal Command value +


1 ⇒ 9
+/-10 V or 0 - 10 V 0...10 V 7 8 9 10 11 12
Signal
2 ⇒ 10 Command value - Rexroth
+/-10 V or 0 - 10 V
VT-MSPA2-1
Gw+
Ramp off 3 x 5* DI enable Gw-
Logic control 4 x 6 DO ready Sw+
Logic control 5 x 11 AO: I - act + Sw-
f
Potentiometer supply 0 V 6 x 12 AO: I - act + Zw
Potentiometer supply +10 V 7 x t<
1
0V 8 ⇒ 2 0V 2 t>
+UB / 24 VDC 9 ⇒ 1 +UB / 24 VDC 3 t<t>
Solenoid 1 10 ⇒ 7 Solenoid A + I w
⊥ wR
Solenoid 1 11 ⇒ 8 Solenoid A -
Solenoid 2 12 ⇒ 3 Solenoid B -
1 2 3 4 5 6
Solenoid 2 13 ⇒ 4 Solenoid B +

No external potentiometer supply, ramp functions can be parameterized with the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


22/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

Block circuit diagram

VT-MSPA2-525-10/V0 (RE 30229)

Ramp: 0.05...5 sec.


2 max.

Dither
Zero ~
max.

1 Zero

+24 V
Ramp
off UB ON
DC
DC
< 21 V

Diff. Logic - control


ampl. Ramp Solenoid
off 1 2
2x Ri +10 V 0 V 24 V=
100 kΩ

1 2 3 4 5 6 7 8 9 10 11 12 13 (min deadband = ±0,3)

2 2
0 V Sign. 0V +10 V Valve
0...+10 V
Imax 10 mA
or 1 1
0,3... +10 V Potm. Supply
UE
1 2
2.5 A

6 V = high 0 V +UB
<
24 V= nom. (max 40 V=) 24 V=

Ramp 21...40 V=
1 2
off
1 or 2 21...28 V= eff.
2 or 1
Logic - control Supply 24 V= nom.

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 23/48

VT-MSRA1-1-1X/V0/0

VT-MSRA1-1-1X/V0/0 VT-MSPA1-2X

+UB / 24 VDC 1 = 1 +UB / 24 VDC


0V 2 = 2 0V
Enable U 3 ⇒ 5 DI enable
Reference potential IN - 4 ⇒ 10 Command value -
Command value IN + 5 ⇒ 9 Command value +
Inversion 6 ⇒ 5* Inversion
Solenoid 7 = 3 Solenoid +
Solenoid 8 = 4 Solenoid -
n. c. 9 x 8 n. c.
n. c. 10 x 11 AO: I - act +
n. c. 11 x 12 AO: I - act -
Ready for operation 12 ⇒ 6 DO ready

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


24/48

wR M0 w (6) (7) 7 Solenoid


U
8
(2) (3) I
5
IN+ >50k U
Comm. value I ok

100
±10 V 4...20 mA 4 Σ ok (4)
Block circuit diagram

IN- >50k U
Gw+ Gw- (5)
VT-MSRA1-1-1X/V0/0 (RE 30227)

(8)
Zw Sw+ Sw- Σ

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


(11)
6
Inversion -1
f

ok
3 (9)
Enable &
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

UL (10) UL 12
Ready
(1)
1 +15V
24 V
DC +10V
M0
2 DC -10V
0V
L0 100 uF -15V

Zw = Zero point, comm. value


1 Power supply unit 7 Current output stage
Sw = Step height
2 Differential amplifier 8 Clock pulse generator
Gw = Amplitude attenuator
3 Comm. value summator 9 Enable function
w = Command value
4 Char. curve generator 10 Fault detection
wR = Comm. value after ramp
5 Amplitude limiter 11 Inversion
= Ready for operation
6 Current controller
= Enable
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 25/48

VT-VSPA1-11-1X/V0/0, VT-VSPA1-10-1X/V0/0

VT-VSPA1-11-1X/V0/0, VT-MSPA1-2X
VT-VSPA1-10-1X/V0/0

n. c. 2b -
n. c. 2d -
Solenoid A 2z ⇒ 3 Solenoid +
n. c. 4b -
n. c. 4d -
Solenoid A 4z ⇒ 4 Solenoid -
n. c. 6b -
n. c. 6d - Rexroth
n. c. 6z -
n. c. 8b -
n. c. 8d -
n. c. 8z -
n. c. 10b -
n. c. 10d - Zw
Actual value ground 10z ⇒ 12 Act out - Gw
Ramp on/off 12b 5* Ramp on/off
n. c. 12d -
n. c. 12z -
Command value 1 (+10 V) 14b ⇒ 9 +In (A5)
t<
n. c. 14d -
t>
n. c. 14z -
Command value 1 (-10 V) 16b ⇒ 10 -In (A5)
t< t>
n. c. 16d - w
f
n. c. 16z - I
n. c. 18b -
Enable 18d ⇒ 5 Enable
n. c. 18z -
n. c. 20b -
VSPA1-11
n. c. 20d -
System ground 20z -
Command value 2 (+4-20 mA) 22b ⇒ 9 +In (F5)
Ready signal 22d ⇒ 6 DO ready
n. c. 22z -
Command value 2 (-4-20 mA) 24b ⇒ 10 -In (F5)
Ramp time external 24d -
n. c. 24z -
n. c. 26b -
n. c. 26d -
n. c. 26z -
Reference external 28b -
Reference of ramp time external 28d -
n. c. 28z -

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


26/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-VSPA1-11-1X/V0/0, VT-VSPA1-10-1X/V0/0

VT-VSPA1-11-1X/V0/0, VT-MSPA1-2X
VT-VSPA1-10-1X/V0/0

Internal command value 30b -


Internal command value
30d -
+/- 10 V
Operating voltage (24 V) 30z ⇒ 1 +UB / 24 VDC
+10 V / 25 mA 32b -
Actual current value 32d ⇒ 11 Act out +
L0 (0 V) 32z ⇒ 2 0V

No external analog ramp time command value available in the VT-MSPA2-2X.

Block circuit diagram


VT-VSPA1-11-1X/V0/0, VT-VSPA1-10-1X/V0/0 (RE 30100)

J2
8 12 W
Ramp b12 Internal
-1 d30
on/off 7 PWM J6 comm. value
Ramp time selec- Up/down T frequency “y”
tion logic f(y, z) “z” UL
+15 V J6
J3 z2 Solenoid
Ramp 9 t< t> f(z) f(z, y) 13
10k 7 U z4
d24 t< t>
time + U PWM
d28 U max t t
external – I
Comm. value + b14 2 J7 14
>50k
U t ramp 11
J5
b16 U Gw
0...+10 V – >50k
ok max/sec “Frequency” ok
b22 J3 J4
Comm. value + I
3 5
b24 100
U 5 50
4...20 mA – 15 I
d32
Actual value
4 z10
10
Zw
d20 Reserved
Enable & ok
d22
6 UL Ready
Enable d18 ≥1 16
Fault detection
J1 b32
UL +10 V / 25 mA
z30
24 V +7,5 V
DC d26
+10 V Reserved
M0 J8
z32
0V DC –7,5 V
Ref. external
L0 Reserve jumper b28
1
z20
System ground

1 Power supply unit 7 Ramp generator 13 Clock pulse generator


2 Differential input 8 Ramp on/off 14 Current output stage
3 Current input 9 Ramp time external 15 Actual value output
4 Zero point adjustment 10 Char. curve generator 16 Fault detection
5 Command value summator 11 Amplitude limiter
6 Enable 12 Command value output

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 27/48

VT-VSPA1-1-1X, VT-VSPA1K-1-1X/

VT-VSPA1-1-1X, VT-MSPA1-2X
VT-VSPA1K-1-1X/

Ramp up/off 2a ⇒ 5* Ramp off


Ramp down/off 2c ⇒ 5* Ramp off
U for ramp off 4ac -
System ground 6ac x 12 Act out -
System ground 8ac -
H2
+9 V 10ac -
Command value 1 12ac -
Gw
M0 14ac -
-9 V 16ac -
UB 0 V 18ac ⇒ 2 +UB 0 V t
Solenoid 20ac ⇒ 3 Solenoid +
Solenoid 22ac ⇒ 4 Solenoid -
UB +24 V 24ac ⇒ 1 +UB 24 VDC t
Actual current value AO 26a
(1 mV = 1 mA)
⇒ 11** Act out + w
I
Ready for operation 26c ⇒ 6 Ready for operation
Command value 2 +10 V, 28ac
M0
⇒ 9 +In
4-20 mA VSPA1
Command value 2 GND 30ac ⇒ 10 -In
Command value 0-6 V 32ac x -

Switching the ramps off separately as provided by the VT-VSPA1-1-1X is not possible with the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Comm. value
2a
28/48
Ramp “w”
“up” off 2c
Ramp 32ac Comm. value
4ac
“down” off 0...6 V
Zw (R130) f-3dB S23 S24 14ac
6
12ac 4 0 off off
Command value 1 Characteris- S15
Σ 2.5 Hz off on
Gw tic curve 1
4 Hz on off
2 Σ
Block circuit diagram

3 7 S23 / S24
VT-VSPA1-1-1X (RE 30111)

5 S16
Characteris- 15
S11...S13 S14 tic curve 2
t t S14 on off Σ ∼
Command value 2 28ac tmax 5s 1s
+10 V U/I Comm. value 2 S11 S12 S13 16

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


4...20 mA/0...20 mA 30ac U 0...10 V off off off
GND ⊥ S25...S27 fclock S25 S26 S27
0...20 mA on on off
1 100 Hz on on on
4...20 mA on on on
6ac 200 Hz off on on
10
300 Hz off off on
8ac
22ac
8
12 u
10ac i 20ac
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

+ 9 V (25 mA)
& 11
14ac S17 off on 9
M0 (25 mA) S17
Imax 1.6 A 0.8 A
16ac 13
– 9 V (25 mA) Actual current
value “I”
18ac
0V DC H2 26a Act. current value
1 mV ≙ 1 mA
24ac
+ 24 V DC 26c Ready for operation
2,5 A T + 24 V
24 V (50 mA)
14 17

1 Differential input 8 Current controller 14 Power supply unit


2, 5, 15 Summator 9 Current output stage 16 Low-pass filter
3 Attenuator, max. command value 10 Clock pulse generator 17 Output “ready for operation”
4 Ramp generator 11 Proportional solenoid of the valve H2 Indicator “ready for operation“
6 Characteristic curve generator 1 12 Command value output Gw Command value attenuation
7 Characteristic curve generator 2 13 Monitoring functions t Ramp time setting
Zw Additional biasing current setting
(R130) (0 to 300 mA or 0 to 600 mA)
2
Ramp off Command
32 value output
4 0...6 V
Zw (R130) 14
6 f-3dB S23 S24
12 4 S15 0 off off
Command value 1 Σ Characteris-
2.5 Hz off on
Gw tic curve 1
Block circuit diagram

2 4 Hz on off
Σ
3 7 S23 / S24
VT-VSPA1K-1-1X/ (RE 30111)

5 Characteris- S16 15
S14 S14 on off tic curve 2
S11...S13
tmax 5s 1s Σ
t t ∼
Command value 2 28
+10 V Comm. value 2 S11 S12 S13
U/I 16
4...20 mA/0...20 mA 0...10 V off off off
30 U
GND ⊥ 0...20 mA on on off S25...S27 fclock S25 S26 S27
1 4...20 mA on on on 100 Hz on on on

6 200 Hz off on on
10
300 Hz off off on
8
22
8
12 u
10 i 20
+ 9 V (25 mA)
& S17 off on 11
14 9
M0 (25 mA) S17 Imax 1.6 A 0.8 A
16 13
– 9 V (25 mA)

18 Actual current
0V DC H2 26
value
24 1 mV ≙ 1 mA
+ 24 V DC
2,5 A T
14
1 Differential input 8 Current cntroller 14 Power supply unit
2, 5, 15 Summator 9 Current output stage 16 Low-pass filter
3 Attenuator, max. command value 10 Clock pulse generator H2 Indicator “ready for operation“
4 Ramp generator 11 Proportional solenoid of the valve Gw Command value attenuation
6 Characteristic curve generator 1 12 Command value monitoring t Ramp time setting
7 Characteristic curve generator 2 13 Monitoring functions Zw Additional biasing current setting
(R130) (0 to 300 mA or 0 to 600 mA)

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 29/48
30/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-VSPA1-2-1X/V0/0, VT-VSPA1-2-1X/V0/A4

VT-VSPA1-2-1X/V0/0, VT-MSPA1-2X
VT-VSPA1-2-1X/V0/A4

Command value 1 2b -
Command value call-up 1 2d -
Solenoid A 2z ⇒ 3 Solenoid +
Command value 2 4b -
Command value call-up 2 4d
Solenoid A 4z ⇒ 4 Solenoid -
Command value 3 6b -
Command value call-up 3 6d -
Rexroth
n. c. 6z -
Command value 4 8b -
Command value call-up 4 8d -
n. c. 8z -
n. c. 10b -
n. c. 10d - Zw
Actual value ground 10z ⇒ 12 Act out - Gw
Ramp on/off 12b 5* Ramp on/off w1

n. c. 12d - w2
w3
n. c. 12z -
w4
Command value 5 + (10 V) 14b ⇒ 9 +In (A5)
t<
n. c. 14d - t>
n. c. 14z -
Command value 5 - (10 V) 16b ⇒ 10 -In (A5) t< t>
f w
n. c. 16d -
I
n. c. 16z -
n. c. 18b -
Enable 18d ⇒ 5 Enable
n. c. 18z -
VSPA1-2
n. c. 20b -
n. c. 20d -
System ground 20z -
Command value 6 +(4-20 mA) 22b ⇒ 9 +In (F5)
Ready signal 22d ⇒ 6 DO ready
n. c. 22z -
Command value 6 - (4-20 mA) 24b ⇒ 10 -In (F5)
Ramp time external 24d -
n. c. 24z -
n. c. 26b -
n. c. 26d -
n. c. 26z -
Reference external 28b -
Ref. of ramp time external 28d -
n. c. 28z -
n. c. 30b -

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 31/48

VT-VSPA1-2-1X/V0/0, VT-VSPA1-2-1X/V0/A4

VT-VSPA1-2-1X/V0/0, VT-MSPA1-2X
VT-VSPA1-2-1X/V0/A4

Internal comm. value +/-10 V 30d -


Operating voltage (24 V) 30z ⇒ 1 +UB / 24 VDC
+10 V / 25 mA 32b -
Actual current value 32d ⇒ 11 Act out +
L0 (0 V) 32z ⇒ 2 0V

The VT-MSPA2-2X does not feature command value call-ups. If these are required, they have to be implemented by
means of command value module VT-SWMA-1-1X. An external analog ramp time command value is not provided by the
VT-MSPA1-2X.

Block circuit diagram


VT-VSPA1-2-1X/V0/0, VT-VSPA1-2-1X/V0/A4 (RE 30115)

J2
9 13 W
Ramp b12 d30 Internal com-
-1
on/off J6 mand value
8 PWM frequency
Ramp time Up/down T
“y”
selection logic J6 f (y, z) “z” UL
+15V J3
10
t< t>
f f
z2 Solenoid
Ramp time (z) (z, y) 14
10k
U z4
+ d24 U t< t>
external – d28 PWM
U max t t
2 I
Comm. value 5: + b14 8 J7
b16
>50k
U 15
0...+10 V – >50k U
6
t ramp 12
J5
Gw “Frequency”
b22 3 ∑ ok max/sec ok
Comm. value 6: + I
b24 100 J3 J4
4...20 mA – U
5 50
16 I
b8 w4 4 d32
Comm. value 41) b6
100k
5 Actual value
~
Comm. value 31) 100k w3 Comm. value
b4 z10
Comm. value 21) 100k w2 selection
b2 w1 Zw 11
Comm. value 11) 100k
logic
d8
Comm. value call-up 41) d20 Reserved
d6
Comm. value call-up 31) Enable & ok
d4 w4 d22
Comm. value call-up 21) UL
d2 w3
Comm. value call-up 11) 17
w2 Fault detection
w1 b32
+10 V/25 mA
8 7
d18
Enable ≥1 d26
J1 Reserved
UL J8
z30
24 V 1 + 7,5 V Reserve jumper b28 Reference
DC + 10 V external
M0
z20
z32 DC System ground
0V – 7,5 V
L0

1) only with option A4

1 Power supply unit 7 Enable 13 Command value output


2 Differential input 8 Ramp generator 14 Clock pulse generator
3 Current input 9 Ramp on/off 15 Current output stage
4 Command value call-ups 10 Ramp time external 16 Actual value output
5 Zero point adjustment 11 Char. curve generator 17 Fault detection
6 Command value summator 12 Amplitude limiter

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


32/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-VSPA2-1-1X/T1, VT-VSPA2-1-1X/T5

VT-VSPA2-1-1X/T1, VT-MSPA2-2X
VT-VSPA2-1-1X/T5

Auxiliary voltage +/-9 V 2a -


Ready for operation 2c ⇒ 6 Ready for operation .../T1

Comm. value call-up 2 4a -


Call-up of “switch auxiliary
4c ⇒ 5* Inversion
Rexroth
voltage over”
H11
Command value call-up 3 6a - H12
Command value call-up 4 6c R1
H1
Command value 3 +/-9 V 8a R2
Comm. value call-up 1 8c - H2
R3
Command value 2 +/-9 V 10a -
H3
Command value 1 +/-9 V 10c - R4
Command value 4 +9 V 12a x 11 Act out + H4
t
Command value 5 +6 V 12c x 12 Act out -
w
14a - IB
Ramp external
14c - IA
Differential input, reference VSPA2
16a ⇒ 10 -In
potential
Differential input, com-
16c ⇒ 9 +In
mand value 6 +/-10 V
Command value after ramp 18a - .../T5
Call-up “ramp off” 18c ⇒ 5* Ramp off
M0 (is raised by 9 V as
against 0 V operating voltage)
20a - Rexroth
+9 V 20c - H11
H12
Solenoid B + 22a ⇒ 3 Solenoid B +
R1 t1
n. c. 22c - H1
Solenoid A - 24a ⇒ 8 Solenoid A - R2 t2
n. c. 24c -
H2
R3 t3
Operating voltage 0 V 26a ⇒ 2 0V H3
-9 V 26c - R4 t4
H4
Solenoid B - 28a ⇒ 4 Solenoid B -
t5
Relay call-up voltage (+24 VDC) 28c -
w
Solenoid A + 30a ⇒ 7 Solenoid A + IB
Enable external 30c ⇒ 5* Enable IA
32a
Operating voltage +UB ⇒ 1 +UB / 24 VDC VSPA2
32c

The VT-MSPA2-2X does not provide a voltage supply for external potentiometers. Command value call-ups and ramp
call-ups are not available in the VT-MSPA2-2X. If these are required, they have to be implemented by means of command
value module VT-SWMA-1-1X.
An external analog ramp time command value is not available in the VT-MSPA2-2X. The functions of “Inversion“ and
“Ramp off“ are only available separately in the VT-MSPA2-2X.

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


X1 Current comm. value at “W” X1
0 to +6 V for solenoid “a” 8
14c
Ramp external 0 to -6 V for solenoid “b”
14a Act. current value IA at “IA“ F
Ba
Act. current value IB at “IB“ w
Comm. value 5 ±6 V 12c 8
F 7 30a
12a Gwa u Solenoid
Comm. value 4 ±9 V IA
Positive command value 8a t F PI i 24a “a”
Comm. value 3 ±9 V
(0 V to 10 V, 0 to 20 mA or 10a 1 5
12 mA to 20 mA) controls Comm. value 2 ±9 V 10c K5
solenoid “b“ Comm. value 1 ±9 V F F F F
R1 R2 R3 R4
Block circuit diagram

Negative command value 3 4 6 IB F


(-10 V to 0 V, -20 mA to
0 mA or 4 mA to 12 mA) K4 ∑ ∑
VT-VSPA2-1-1X/T1 (RE 30112)

controls solenoid “a“ K3


K1 K2 J5,J6
18a Zw Gwb 7
Comm. value after ramp Solenoid
22a
Differential Command value 6 16c PI i “b”
u/i u 28a
input 16a
Ref. potential/GND u 2 11
+ UB J1…J4 10 8
=1 Bb
J7: Enable internal J7
Enable external (+UB) 30c
‡1 2c Ready for
F
H11 – operation
2a K6 10 F
Auxiliary voltage ±9 V H12
+ =1 32c
9 3,15 AT
Measurement zero (M0) raised by + 9 V 20c 32a + UB
20a =
9 V as against 0 V operating voltage M0 26c Operating
– 9V 2200 µ F voltage
8c K1 1 H1 F 26a
Command value call-up 1 0V
4a K2 H2 F
Command value call-up 2
6a K3 H3 F
Command value call-up 3 F
6c K4 H4
Command value call-up 4
Call-up “ramp off” 18c K5 on front panel
Call-up of “switch aux. voltage over” 4c K6
28c
Relay call-up voltage (+24 V)

H1 to H4 LED lamps for comm. value call-ups Ba Biasing current, solenoid “a“ 1 Command values 8 Output stage w/ clock pulse generator
K1 to K6 Call-up relay Bb Biasing current, solenoid “b” 2 Differential input 9 Power supply unit
R1 to R4 Command values t Ramp time 3, 6 Summator 10 Monitoring functions
Gwa Comm. value attenuator, solenoid “a“ 4 Ramp generator 11 Cable break monitoring
Gwb Comm. value attenuator, solenoid “b“ 5 Step function (with 4 to 20 mA only)
Zw Zero point command value 7 PI current controller

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 33/48
X1 K1.2 K2.2 Current comm. value at “W” X1
0 to +6 V for solenoid “a”
34/48
K3.2 K4.2 8
14c 0 to -6 V for solenoid “b”
F F F F F
Ramp external 14a t5 t1 t2 t3 t4 Act. current value IA at “IA“
Act. current value IB at “IB“ w F Ba
Comm. value 5 ±6 V 12c 8
F 7 30a Solenoid
12a Gwa u
Comm. value 4 ±9 V IA
Positive command value 8a i 24a “a”
Comm. value 3 ±9 V PI
(0 V to 10 V, 0 to 20 mA or 10a 1 5
12 mA to 20 mA) controls Comm. value 2 ±9 V K5
10c
solenoid “b“ Comm. value 1 ±9 V F F F F
Block circuit diagram

R1 R2 R3 R4
Negative command value 3 4 6 IB F
(-10 V to 0 V, -20 mA to
VT-VSPA2-1-1X/T5 (RE 30112)

0 mA or 4 mA to 12 mA) K4 ∑ ∑
controls solenoid “a“ K3
K1 K2 J5,J6
Comm. value after ramp 18a Zw Gwb 7 Solenoid
22a

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


16c “b”
Differential Command value 6 u/i PI i 28a
input 16a u
Ref. potential/GND u 2 11
+ UB J1…J4 10 8
=1 Bb
J7: Enable internal J7
30c
Enable external (+UB) ‡1
F 2c
H11 Ready for operation
– 10
2a K6 F
Auxiliary voltage ±9 V H12
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

+ =1 32c
9 3,15 AT
20c 32a + UB
Measurement zero (M0) raised by + 9 V =
20a
9 V as against 0V operating voltage M0 Operating
26c
– 9V 2200 µ F voltage
8c K1 1 H1 F 26a
0V
Command value call-up 1 F
4a K2 H2
Command value call-up 2 K3 H3 F
6a
Command value call-up 3 6c K4 H4 F
Command value call-up 4 K5
18c on front panel
Call-up “ramp off”
4c K6
Call-up of “switch aux, voltage over”
28c
Relay call-up voltage (+24 V)

H1 to H4 LEDs for comm. value call-ups Ba Biasing current, solenoid “a“ 1 Command values 8 Output stage w/ clock pulse generator
K1 to K6 Call-up relay Bb Biasing current, solenoid “b” 2 Differential input 9 Power supply unit
R1 to R4 Command values t1 to t5 Ramp time 3, 6 Summator 10 Monitoring functions
Gwa Comm. value attenuator, solenoid “a“ 4 Ramp generator 11 Cable break monitoring
Gwb Comm. value attenuator, solenoid “b“ 5 Step function (with 4 to 20 mA only)
Zw Zero point command value 7 PI current controller
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 35/48

VT-VSPA2-1-2X/V0/T1, VT-VSPA2-1-2X/T5

VT-VSPA2-1-2X/V0/T1, VT-MSPA2-2X
VT-VSPA2-1-2X/T5

Command value 1 (+/-10 V) 2b - .../T1


Command value call-up 1 2d
-
(24 V input)
2z REXROTH
Solenoid A + ⇒ 7 Solenoid A +
Command value 2 (+/-10 V) 4b - -1 T

Command value call-up 2


4d -
(24 V input)
4z Zw
Solenoid A - ⇒ 8 Solenoid A -
w1
Command value 3 (+/-10 V) 6b x - w2
Comm. value call-up 3 (24 V w3
6d - w4
input)
Solenoid B - 6z ⇒ 3 Solenoid B +
Command value 4 (+/-10 V) 8b -
Comm. value call-up 4 (24 V
8d - t
input)
Solenoid B + 8z ⇒ 4 Solenoid B -
Inversion of command value I w
10b ⇒ 5* Inversion
(24 V input) t
Ramp call-up 1 (24 V input) 10d
System ground 10z ⇒ 12 Act out - VSPA2
Ramp on/off (24 V input) 12b ⇒ 5* Ramp on/off
Ramp call-up 2 (24 V input) 12d -
n. c. 12z -
14b .../T5
Command value 5 (+/-10 V) ⇒ 9 +In (A5)
Ramp call-up 3 (24 V input) 14d -
n. c. 14z - REXROTH
Command value 5 (+/-10 V) 16b ⇒ 10 -In (A5)
-1 4Q T
Ramp call-up 4 (24 V input) 16d -
n. c. 16z -
Remote select 1** 18b - Zw
Enable 18d ⇒ 5 Enable w1
w2
n. c. 18z -
w3
4-quadrant operation 4-quadrant operation w4
20b ⇒ 5*
(24 V input) (24 V input) t1
n. c. 20d - t2
t3
System ground 20z - t4
Command value 6 + (4-20 mA) 22b ⇒ 9 +In (F5) t5
Ready signal (24 V, H-ac- EF
012

22d ⇒ 6 DO ready
3456
BCD

tive, 50 mA)
7 89 A

n. c. 22z - I w
v
Command value 6 - (4-20 mA) 24b ⇒ 10 -In (F5)
Ramp time external 24d - VSPA2
n. c. 24z -
Measuring signal, ramp time 26b -

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


36/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-VSPA2-1-2X/V0/T1, VT-VSPA2-1-2X/T5

VT-VSPA2-1-2X/V0/T1, VT-MSPA2-2X
VT-VSPA2-1-2X/T5

n. c. 26d -
n. c. 26z -
Reference potential for
28b -
outputs (M0)
Reference of ramp time external 28d -
n. c. 28z -
-10 V / 25 mA 30b -
Internal command value +/-10 V 30d -
Operating voltage (24 V) 30z ⇒ 1 +UB / 24 VDC
+10 V / 25 mA 32b -
Actual current value 32d ⇒ 11 Act out +
L0 (0 V) 32z ⇒ 2 0V

The VT-MSPA2-2X does not provide a voltage supply for external potentiometers. Command value call-ups and ramp
call-ups are not available in the VT-MSPA2-2X. If these are required, they have to be implemented by means of command
value module VT-SWMA-1-1X.
An external analog ramp time command value is not available in the VT-MSPA2-2X. The functions of “inversion“ and
“ramp off“ are only available separately in the VT-MSPA2-2X.

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Ramp on/off Reserved
Internal comm. value

Reserved
Solenoid b
UP/DOWN
Controller

Ramp time external Solenoid a


Block circuit diagram

Comm. value 5
±10 V
VT-VSPA2-1-2X/V0/T1 (RE 30110)

t t
Command value 6 t
4...20 mA t t

Command value 4
Command value 3
Command value 2
Command value 1

Command value Act. current value


call-ups 1 to 4 Reserved
Enable
Ready for operation
Inversion Fault detection
Enable Enable +10 V / 25 mA

-10 V / 25 mA
Operating
voltage

Measuring signal
Ramp time

M0

System ground

1 Power supply unit 6 Comm. value summator 11 Amplitude limiter 16 Current output stage
2 Differential input 7 Comm. value inversion 12 Command value output 17 Fault detection
3 Current input 8 Enable function 13 Clock pulse generator ok1 Output stage enable signal
4 Comm. value selection logic 9 Ramp generator 14 Act. current value output ok2 Card monitoring
5 Zero point adjustment 10 Char. curve generator 15 Current controller

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 37/48
Ramp on/off Reserved
4-quadrant operation Internal comm. value
38/48

Reserved
Ramp call-ups Solenoid b

Controller

Ramp time Solenoid a


Block circuit diagram

external
Command value 5
VT-VSPA2-1-2X/T5 (RE 30110)

±10 V

Command value 6
4...20 mA

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Command value 4
Command value 3
Command value 2
Command value 1

Comm. value call-ups Act. current value


1 to 4 Reserved
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

Enable
Ready for operation
Inversion Fault detection
Enable Enable +10 V / 25 mA

-10 V / 25 mA
Operating
voltage

Measuring signal

M0

System ground

1 Power supply unit 6 Command value summator 11 Amplitude limiter 16 Current output stage ok2 Card monitoring
2 Differential input 7 Command value inversion 12 Command value output 17 Fault detection
3 Current input 8 Enable function 13 Clock pulse generator 18 Meas. point changeover switch
4 Comm. value selection logic 9 Ramp generator 14 Act. current value output 19 Ramp time selection logic
5 Zero point adjustment 10 Char. curve generator 15 Current controller ok1 Output stage enable signal
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 39/48

VT-VSPA2-50-1X/T1, VT-VSPA2-50-1X/T5

VT-VSPA2-50-1X/T1, VT-MSPA2-2X
VT-VSPA2-50-1X/T5

Auxiliary voltage 2a x 6 Ready for operation


Ready for operation 2c -
Comm. value call-up 2 4a - .../T1
Call-up of “switch auxiliary
4c ⇒ 5* Inversion
voltage over”
Comm. value call-up 3 6a x 5 Enable Rexroth
H11
Comm. value call-up 4 6c H12
Command value 3 +/-9 V 8a w1
H1
Comm. value call-up 1 8c - w2
H2
Command value 2 +/-9 V 10a - w3
H3
Command value 1 +/-9 V 10c - w4
H4
Command value 4 +9 V 12a x 11 Act out +
t
Command value 5 +6 V 12c x 12 Act out -
W 0 ... ± 6 V
External ramp (pos. comm. 14a - IB mV = mA
IA mV = mA
value = solenoid B / neg.
14c -
comm. value = solenoid A)
VSPA2-50
Differential input, reference
16a ⇒ 10 -In
potential
Differential input, com- .../T5
16c ⇒ 9 +In
mand value 6 +/-10 V
Command value after ramp 18a -
Rexroth
Call-up “ramp off” 18c ⇒ 5* Ramp off
H11
M0 (is raised by 9 V as H12
20a - w1 t1
against 0 V operating voltage) H1
+9 V 20c - w2 t2
H2
Solenoid B + 22a ⇒ 3 Solenoid B + w3 t3
H3
n. c. 22c - w4 t4
H4
Solenoid A - 24a ⇒ 8 Solenoid A -
t5
n. c. 24c - W 0 ... ± 6 V
IB mV = mA
Operating voltage 0 V 26a ⇒ 2 0V IA mV = mA
-9 V 26c -
Solenoid B - 28a ⇒ 4 Solenoid B - VSPA2-50

Relay call-up voltage (+24 V) 28c -


Solenoid A + 30a ⇒ 7 Solenoid A +
n. c. 30c -
32a
Operating voltage +UB ⇒ 1 +UB / 24 VDC
32c

The VT-MSPA2-2X does not provide a voltage supply for external potentiometers. Command value call-ups and ramp
call-ups are not available in the VT-MSPA2-2X. If these are required, they have to be implemented by means of command
value module VT-SWMA-1-1X.
An external analog ramp time command value is not available in the VT-MSPA2-2X. The functions of “inversion“ and
“ramp off“ are only available separately in the VT-MSPA2-2X.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


X1 X1
Current comm. value at “W” 8
14c
40/48

0 to +6 V for solenoid “a”


Ramp external 14a 0 to -6 V for solenoid “b”
Act. current value IA at “IA“
F
W Ba (R7)
Act. current value IB at “IB“ Solenoid “a”
12c 8
Command value 5 ±6 V 7 30a
12a F u
Command value 4 ±9 V IA
8a PI i 24a
Command value 3 ±9 V t F
10a 1 5
Command value 2 ±9 V K5
10c
Block circuit diagram

Command value 1 ±9 V F F F F
w1 w2 w3 w4
3 4
6 IB F
VT-VSPA2-50-1X/T1 (RE 30113)

K4 Σ Σ
K3 J5, J6
K1 K2
Comm. value 6 Command value 18a Zw 7

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Solenoid “b”
(16c/16a): after ramp (R6) 22a
0 to 10 V, 16c PI i
±10 V I← u/i
0 to 20 mA or or 16a u 28a
0V I→ u
4 to 12 mA 2 11
+UB J1… J4 10 8
controls solenoid “b”;
-10 V to 0,
Bb (R8)
=1
-20 mA to 0 J7: Enable internal J7
or 30c
12 to 20 mA
Enable external (+UB) ≥1
2c
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

F Ready for
controls solenoid “a“ H11 –
K6 10 F operation
Auxiliary voltage ±9 V
2a
H12
+ =1 32c
9 2,5 AT
20c 32a +UB
+9 V =
Measurement zero (M0) raised by 20a
M0 Operating
9 V as against 0 V operating voltage –9 V 26c voltage
2200 µF
8c K1 1 H1 F 26a
Comm. value call-up 1 0V
4a K2 H2 F
Comm. value call-up 2
6a K3 H3 F
Comm. value call-up 3
6c K4 H4 F
Comm. value call-up 4 = on front panel
18c K5
Call-up “ramp off”
Call-up of “switch aux. voltage over”
4c K6 1 Command values 7 PI current controller
28c
Relay call-up voltage (+24 V) 2 Differential input 8 Output stage w/ clock pulse generator

H1 to H4 LEDs for comm. value call-ups Ba (R7) Biasing current, solenoid “a“ 3; 6 Summator 9 Power supply unit

K1 to K6 Call-up relay Bb (R8) Biasing current, solenoid “b” 4 Ramp generator 10 Monitoring functions

w1 to w4 Command values t Ramp time 5 Step function 11 Cable break monitoring


(with 4 to 20 mA only)
Zw (R6) Zero point, command value
X1 K1.2 K2.2 Current comm. value at “W”
X1
K3.2 K4.2 0 to +6 V for solenoid “a”
14c 0 to -6 V for solenoid “b” 8
Ramp external F F F F F
t5 t1 t2 t3 t4 Act. current value IA at “IA“
14a
Act. current value IB at “IB“ F
W Ba (R7)
12c 8 Solenoid “a”
Command value 5 ±6 V 7 30a
12a F
Command value 4 ±9 V IA u
8a i 24a
Command value 3 ±9 V PI
10a 1 5
Command value 2 ±9 V
Block circuit diagram

10c K5
Command value 1 ±9 V F F F F
w1 w2 w3 w4
3 4
VT-VSPA2-50-1X/T5 (RE 30113)

6 IB F

K4 Σ Σ
K3
K1 K2 J5, J6
Comm. value 6 Comm. value after 18a Zw
(16c/16a): (R6)
7 Solenoid “b”
ramp 22a
0 to 10 V, ±10 V I←
16c PI i
0 to 20 mA or or u/i u 28a
0V I→ 16a
4 to 12 mA con- u 2 11
trols solenoid “b”; +UB J1… J4 10 8
-10 V to 0, Bb (R8)
J7: Enable internal
=1
-20 mA to 0 J7
or 30c
Enable external (+UB) ≥1
12 to 20 mA 2c Ready for
F
controls solenoid “a“ H11 – operation
2a K6 10 F
Auxiliary voltage ±9 V H12
+ =1 32c
20c
9 2,5 AT 32a +UB
+9 V =
20a
Measurement zero (M0) raised by 9 M0 Operating
V as against 0 V operating voltage –9 V 26c voltage
2200 µF
8c K1 1 H1 F 26a
Comm. value call-up 1 0V
4a K2 H2 F
Comm. value call-up 2
6a K3 H3 F
Comm. value call-up 3
6c K4 H4 F = on front panel
Comm. value call-up 4
18c K5
Call-up “ramp off”
4c K6
Call-up of “switch aux. voltage over”
28c 1 Command values 7 PI current controller
Relay call-up voltage (+24 V)
2 Differential input 8 Output stage w/ clock pulse generator
H1 to H4 LEDs for command value call-ups Ba (R7) Biasing current, solenoid “a“ 3; 6 Summator 9 Power supply unit
K1 to K6 Call-up relay Bb (R8) Biasing current, solenoid “b” 4 Ramp generator 10 Monitoring functions
w1 to w4 Command values t1 to t5 Ramp time 5 Step function 11 Cable break monitoring
Zw (R6) Zero point, command value (with 4 to 20 mA only)

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 41/48
42/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

VT-SWMA-1-1X/V0/0

Actuating variable
+UB 1 7
Operating output
7 8 9 10 11 12
voltage
REXROTH 0V 2 8 Reference potential
VT-SWMA- 1
4-Q Inv Quadrant
t1 w1 +U4-Q 3 9 Comm. value call-up 1
operation
t2 w2
t3 w3 Reference
t4 w4 4 10 Comm. value call-up 2
t5 G Differential potential
t w Z input
Comm. value call-up 3
±Ucomm 5 11
1 2 3 4 5 6
Comm. value Comm. value call-up 4
+UInv 6 12
inversion

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Comm. value 6
inversion
Inv
Differential input: 2
5
Comm. value ±10 V u Z
Block circuit diagram

4 u 14
Reference potential G w
–Uref 4 3
–Uref 5
w4
VT-SWMA-1-1X/V0/0 (RE 29902)

+Uref γ δ 7 Actuating
w3 Σ ±1 variable
+Uref α β t
w2 6 15
w1
8 Reference
7 potential
9
Call-up of comm value 1 13
t
10
Call-up of comm value 2
11
Call-up of comm value 3
12
Call-up of comm value 4
+/– 9
10
3 8
Quadrant operation Ramp time selection logic
4-Q
α β γ δ
+ 15 V
1
t1 t2 t3 t4 t5 12
1
+ UB DC – 15 V 11
Operating + Uref
voltage 2 – Uref
0V DC
L0 M0

1 Power supply unit 6 Command value inversion 11 Ramp time call-ups


2 Differential amplifier 7 Priority logic 12 Ramp time potentiometer “t5”
3 Summator with zero point potentiometer 8 Quadrant recognition 13 Test jack of “ramp time signal”
4 Amplitude attenuator 9 Polarity recognition 14 Test jack of “internal comm. value”
5 Call-up signals 10 Recognition of actuating 15 Matching amplifier
variable change (up/down)

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 43/48
Functions Successor

Amplifier Valves Out-


Command
44/48

put Ramp Further VT-MSPAx2x Command value module


values
stage

Enable

ramp off
4Q ramp
Inversion
De- RoHS End of

1 solenoid
Ready DO
Data Data

2 solenoids
Mat. no. Type sign confor- phase- Families Mat. no. Type Mat. no. Type

Digital input,
sheet sheet

Input 4..20mA
mity out

Input 0 / ±10 V
Ext. ramp time
(analog output)

Ext. pot. supply


Act. current value

Selection of simple/
Up/down ramp can be

Comm. value call-ups


switched off separately

Internal comm. value


R901439034 VT-MSPA1-2X/A5/000/000 Module Yes 30232 - All valves of the old series below are considered. x - - x - x - x x - - x - x x
R901439036 VT-MSPA1-2X/F5/000/000 Module Yes 30232 - - x - x - x - x x - - x - x x

New
R901439037 VT-MSPA2-2X/A5/000/000 Module Yes 30232 - x - - x - - x x x - - x x x x

amplifier
R901439038 VT-MSPA2-2X/F5/000/000 Module Yes 30232 - - x - x - - x x x - - x x x x
R900211788 VT 11118-1X/ Module No 30218 Jul 19 3DREP6...-2X; 4WRZ…-7X; x - - - - - x - - - - x - - - R901439037 VT-MSPA2-2X/A5/000/000 - - -
3DRE…7X…G24-8…; DBEM10…-7X…G24-8…; DBEM20…-7X...
G24-8…; DBEM30…-7X...G24-8…; DBEP6…-1X; DBET-6X…
R900033828 VT 2000-5X/ Card Yes 29904 Dec 20 x - x x - x - x - x - - - - x R901439034 VT-MSPA1-2X/A5/000/000 - - -
G24-8…; DRE.10…6X…G24-8…; DRE.20…6X…G24-8…;
DRE.30…6X…G24-8…; ZDRE10...-2X…G24-8…;
R900020298 VT 3000-3X/ Card Yes 29935 Dec 20 DBEP6…-1X x - x x x - x x - - x - x - x R901439037 VT-MSPA2-2X/A5/000/000 R900942541 VT-SWMA-1-1X/V0/0 29902
R900020299 VT 3006-3X/ Card Yes 29926 Dec 20 DBEP6…-1X x - x x x - x x x x x - x - x R901439037 VT-MSPA2-2X/A5/000/000 R900942541 VT-SWMA-1-1X/V0/0 29902
R900030647 VT11132-1X/ Module Yes 29865 Jul 19 (Z)DRE6...-1X… x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


R901142355 VT-MSPA1-10-1X/V0 Module Yes 30223 Jul 19 (Z)DRE6...-1X… x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
(Z)DBE6.-2X…; 3DRE...7X…G24…; DRE.10…6X…G24…;
R901142360 VT-MSPA1-11-1X/V0/0 Module Yes 30223 Jul 19 x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
DRE.20…6X…G24…; DRE.30…6X…G24…; ZDRE10...-2X…G24…
DBEM10…-7X…G24…; DBEM20…-7X...G24…; DBEM30…-7X...
R900702060 VT-MSPA1-1-1X/V0/0 Module Yes 30223 Jul 19 x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
G24…; DBET-6X…G24…
3DRE…7X…G24-8…; DBEM10…-7X…G24-8…; DBEM20…-7X...
R901288142 VT-MSPA1-150-1X/V0/0 Module Yes 30224 Jul 19 x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
G24-8…; DBEM30…-7X...G24-8…; DBET-6X…G24-8…
3DRE…7X…G24-8…; DBEM10…-7X…G24-8…; DBEM20…-7X...
R901288145 VT-MSPA1-30-1X/V0/0 Module Yes 30224 Jul 19 x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
G24-8…; DBEM30…-7X...G24-8…; DBET-6X…G24-8…
R900249810 VT-MSPA1-50-1X/V0 Module Yes 30225 Jul 19 Valves with 2.5 A x - - - - x - - - - - - - - - R901439034 VT-MSPA1-2X/A5/000/000 - - -
R901010980 VT-MSPA2-1-1X/V0/0 Module No 30228 Jul 19 4WRA10…-2X; 4WRA6…-2X x - - - - - x - - - - x x - - R901439037 VT-MSPA2-2X/A5/000/000 - - -
R901197784 VT-MSRA1-1-1X/V0/0 Module No 30227 Jul 19 4WRPH6…-2X(SO855) x - - - - x - - - - - x x x - R901439034 VT-MSPA1-2X/A5/000/000 - - -
VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

R901386328 VT-MSRA1-1-1X/V001 Module No 30227 Jul 19 4WRPH6…-2X(SO855) - x - - - x - - - - - x x x - R901439036 VT-MSPA1-2X/F5/000/000 - - -


R901439034 VT-MSPA1-2X/A5/000/000
R901152628 VT-VSPA1-10-1X/V0/0 Card No 30100 Dec 20 (Z)DRE6...-1X... x x - x - x - x - - x x - x x - - -
R901439036 VT-MSPA1-2X/F5/000/000
(Z)DBE6.-2X…; 3DRE...7X…G24…; DRE.10…6X…G24…; R901439034 VT-MSPA1-2X/A5/000/000
R901152637 VT-VSPA1-11-1X/V0/0 Card No 30100 Dec 20 x x - x - x - x - - x x - x x - - -
DRE.20…6X…G24…; DRE.30…6X…G24…; ZDRE10...-2X…G24… R901439036 VT-MSPA1-2X/F5/000/000
R901439034 VT-MSPA1-2X/A5/000/000
R900033823 VT-VSPA1-1-1X/ Card Yes 30111 Dec 20 3DRE…7X…G24-8…; DBEP6…-1X x x x x - x - x - - - - - x x - - -
R901439036 VT-MSPA1-2X/F5/000/000
VT-VSPA1-1- R901439034 VT-MSPA1-2X/A5/000/000
R900934744 Card Yes 30111 Dec 20 3DRE…7X…G24-8…; DBEP6…-1X x x x x - x - x - - - - - x x - - -
1X/002/60SEC R901439036 VT-MSPA1-2X/F5/000/000

Old amplifier
R901439034 VT-MSPA1-2X/A5/000/000
R900966500 VT-VSPA1-1-1X/004 Card Yes 30111 Dec 20 3DRE…7X…G24-8…; DBEP6…-1X x x x x - x - x - - - - - x x - - -
R901439036 VT-MSPA1-2X/F5/000/000
30111- R901439034 VT-MSPA1-2X/A5/000/000
R900978827 VT-VSPA1-1-1X/005 Card Yes Dec 20 3DRE…7X…G24-8…; DBEP6…-1X x x x x - x - x - - - - - x x - - -
05 R901439036 VT-MSPA1-2X/F5/000/000
DBEM10…-7X…G24…; DBEM20…-7X...G24…; DBEM30…-7X... R901439034 VT-MSPA1-2X/A5/000/000
R900782310 VT-VSPA1-2-1X/V0/0 Card No 30115 Dec 20 x x - x x x - x - - x x - x x R900942541 VT-SWMA-1-1X/V0/0 29902
G24…; DBET-6X…G24… R901439036 VT-MSPA1-2X/F5/000/000
DBEM10…-7X…G24…; DBEM20…-7X...G24…; DBEM30…-7X... R901439034 VT-MSPA1-2X/A5/000/000
R901002761 VT-VSPA1-2-1X/V0/A4 Card No 30115 Dec 20 x x - x x x - x - - x x - x x R900942541 VT-SWMA-1-1X/V0/0 29902
G24…; DBET-6X…G24… R901439036 VT-MSPA1-2X/F5/000/000
R901439034 VT-MSPA1-2X/A5/000/000
R900053778 VT-VSPA1K-1-1X/ Card Yes 30111 Dec 20 DBEP6…-1X x x x x - x - x - - - - - - x - - -
R901439036 VT-MSPA1-2X/F5/000/000
R901439037 VT-MSPA2-2X/A5/000/000
R900029790 VT-VSPA2-1-1X/T5 Card Yes 30112 Jul 19 4WRA10…-2X; 4WRA6…-2X x x x x x - x x - - - x x x - R900942541 VT-SWMA-1-1X/V0/0 29902
R901439038 VT-MSPA2-2X/F5/000/000
3DREP6...-2X; 3DREP6…-2X; 3DREP6…-2X... (SO0674); R901439037 VT-MSPA2-2X/A5/000/000
R901002090 VT-VSPA2-1-2X/V0/T1 Card Yes 30110 Dec 20 x x - x x - x x - - x x x x x R900942541 VT-SWMA-1-1X/V0/0 29902
4WRA10…-2X; 4WRA6…-2X; 4WRZ…-7X R901439038 VT-MSPA2-2X/F5/000/000
3DREP6...-2X; 3DREP6…-2X; 3DREP6…-2X... (SO0674); R901439037 VT-MSPA2-2X/A5/000/000
R901002095 VT-VSPA2-1-2X/V0/T5 Card Yes 30110 Dec 20 x x - x x - x x - - x x x x x R900942541 VT-SWMA-1-1X/V0/0 29902
4WRA10…-2X; 4WRA6…-2X; 4WRZ…-7X R901439038 VT-MSPA2-2X/F5/000/000
R901439037 VT-MSPA2-2X/A5/000/000
R900214081 VT-VSPA2-50-1X/T1 Card Yes 30113 Dec 20 3DREP6...-2X; 4WRZ…-7X x x x x x - x x - - x x x x - R900942541 VT-SWMA-1-1X/V0/0 29902
R901439038 VT-MSPA2-2X/F5/000/000
(Z)DBE6.-2X…; (Z)DRE6...-1X…; 3DRE...7X…G24…; 3DREP6...-
R901439034 VT-MSPA1-2X/A5/000/000
2X; 4WRA10…-2X; 4WRA6…-2X; 4WRZ…-7X; DBEM10…-7X…
R901439036 VT-MSPA1-2X/F5/000/000
R901077297 VT-VSPD-1-2X/V0/0-0-1 Card No 30523 Jul 19 G24…; DBEM20…-7X...G24…; DBEM30…-7X...G24…; DBEP6…- x x - x x x x x - x x x - x x R900942541 VT-SWMA-1-1X/V0/0 29902
R901439037 VT-MSPA2-2X/A5/000/000
1X; DBET-6X…G24…; DRE.10…6X…G24…; DRE.20…6X…G24…;
R901439038 VT-MSPA2-2X/F5/000/000
DRE.30…6X…G24…; ZDRE10...-2X…G24…
(Z)DBE6.-2X…; (Z)DRE6...-1X…; 3DRE...7X…G24…; 3DREP6...-
R901439034 VT-MSPA1-2X/A5/000/000
2X; 4WRA10…-2X; 4WRA6…-2X; 4WRZ…-7X; DBEM10…-7X…
R901439036 VT-MSPA1-2X/F5/000/000
R901161533 VT-VSPD-1-2X/V0/1-0-1 Card No 30523 Jul 19 G24…; DBEM20…-7X...G24…; DBEM30…-7X...G24…; DBEP6…- x x - x x x x x - x x x - x x R900942541 VT-SWMA-1-1X/V0/0 29902
R901439037 VT-MSPA2-2X/A5/000/000
1X; DBET-6X…G24…; DRE.10…6X…G24…; DRE.20…6X…G24…;
R901439038 VT-MSPA2-2X/F5/000/000
DRE.30…6X…G24…; ZDRE10...-2X…G24…
Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 45/48

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Industrial Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified only serve to describe the product. No statements concern-
Telephone +49 (0) 93 52 / 40 30 20 ing a certain condition or suitability for a certain application can be derived
my.support@boschrexroth.de from our information. The information given does not release the user from the
www.boschrexroth.com obligation of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


46/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Industrial Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified only serve to describe the product. No statements concern-
Telephone +49 (0) 93 52 / 40 30 20 ing a certain condition or suitability for a certain application can be derived
my.support@boschrexroth.de from our information. The information given does not release the user from the
www.boschrexroth.com obligation of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06


Analog valve amplifier | VT-MSPA1-2X; VT-MSPA2-2X 47/48

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Industrial Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified only serve to describe the product. No statements concern-
Telephone +49 (0) 93 52 / 40 30 20 ing a certain condition or suitability for a certain application can be derived
my.support@boschrexroth.de from our information. The information given does not release the user from the
www.boschrexroth.com obligation of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.

RE 30232-Z, edition: 2018-06, Bosch Rexroth AG


48/48 VT-MSPA1-2X; VT-MSPA2-2X | Analog valve amplifier

Notes

Bosch Rexroth AG © This document, as well as the data, specifications and other information set
Industrial Hydraulics forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified only serve to describe the product. No statements concern-
Telephone +49 (0) 93 52 / 40 30 20 ing a certain condition or suitability for a certain application can be derived
my.support@boschrexroth.de from our information. The information given does not release the user from the
www.boschrexroth.com obligation of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.

Bosch Rexroth AG, RE 30232-Z, edition: 2018-06