Characteristics: Our in Vitro Identity
Characteristics: Our in Vitro Identity
Characteristics: Our in Vitro Identity
THROUGHPUT
Up to 180 tests per hour with integrated ISE module
Up to 120 photometric tests per hour
ANALYTICAL METHODS
End point mono or bichromatic
Fixed time
Kinetic
Differential sample blank
Mono, double, triple reagents methods
TECHNICAL SPECIFICATIONS
Calibration with linear/no-linear curves up to 8 points, auto-dilution of the calibration curve
(linear regression, linear piece-wise, cubic spline, polynomial)
19 reagents on board plus diluent
Reagent volume: 1÷400 μL
OUR IN VITRO
SCL EN/Palio100/2015-10/Ed 01 - All pictures and specifications included in this document are purely indicative and may be subject to change without notice
Sample volume: 1÷300 μL
Typical reaction volume: 200 μL
Wavelengths on board: from 340 nm to 700 nm plus one free position DIAGNOSTICS IDENTITY
Photometric linearity: 0÷3.0 OD
Light source: Long life halogen lamp (2000 hours)
80 on-board re-washable Bionex© cuvettes THE IDEAL CHOICE FOR YOUR LABORATORY
Water consumption: 3/4 liters per hour
Reagent cooler: 14 °C below ambient temperature
Reaction temperature: +37 °C ± 0.1 °C
9/15 sample/calibrator/control positions on primary tubes (Ø 12÷13 x 75/85 mm), sample cups (3 ml).
Arm equipped with liquid level detector (capacitive) and shock sensor
High precision micro-metering pump to dispense reagents and samples (no syringe)
Environment temperature: 18-32 °C
OTHER SPECIFICATIONS
All-in-one touch screen computer
L.I.S.: Bi-directional connection
Operating system: Windows©
Cuvette washing: Automatic washing station
Dimensions L x W x H: 76x62x64 cm
Weigh (net): 42 Kg
ANALYTICAL METHODS
End point mono or bichromatic
Fixed time
Kinetic
Differential sample blank
Mono, double, triple reagents methods
TECHNICAL SPECIFICATIONS
Calibration with linear/no-linear curves up to 8 points, auto-dilution of the calibration curve
(linear regression, linear piece-wise, cubic spline, polynomial)
19 reagents on board plus diluent
Reagent volume: 1÷400 μL
OUR IN VITRO
SCL EN/Palio100/2015-10/Ed 01 - All pictures and specifications included in this document are purely indicative and may be subject to change without notice
Sample volume: 1÷300 μL
Typical reaction volume: 200 μL
Wavelengths on board: from 340 nm to 700 nm plus one free position DIAGNOSTICS IDENTITY
Photometric linearity: 0÷3.0 OD
Light source: Long life halogen lamp (2000 hours)
80 on-board re-washable Bionex© cuvettes THE IDEAL CHOICE FOR YOUR LABORATORY
Water consumption: 3/4 liters per hour
Reagent cooler: 14 °C below ambient temperature
Reaction temperature: +37 °C ± 0.1 °C
9/15 sample/calibrator/control positions on primary tubes (Ø 12÷13 x 75/85 mm), sample cups (3 ml).
Arm equipped with liquid level detector (capacitive) and shock sensor
High precision micro-metering pump to dispense reagents and samples (no syringe)
Environment temperature: 18-32 °C
OTHER SPECIFICATIONS
All-in-one touch screen computer
L.I.S.: Bi-directional connection
Operating system: Windows©
Cuvette washing: Automatic washing station
Dimensions L x W x H: 76x62x64 cm
Weigh (net): 42 Kg