Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Explanation of product specifications From Armstrong :

1. Armstrong Fine Fissured Open Plan with HumiGuard Plus, 600x1200x16mm


The Correct specification is Fine Fissured Board (3570) NRC 0.60, CAC 35, LR
85%, Fire Reaction Class 0/1 based on BS 476 part 6&7

2. Armstrong Fine Fissured Ceramaguard with HumiGuard, 600x1200x16mm not


available in Asia.
Instead we offer products suitable for wet area : Metal Lay In Tile Tegular 8 Micro
Perforated (M9) Warna White dengan spesifikasi NRC 0.75, CAC 18
Material choice : Alum 1.0mm or Steel 0.7mm, Finish powder coating.

3. Armstrong Ultima Lay In and Tegular with AirGuard coating, 600x1200x20mm


The Correct specification is Ultima Tegular 24 (1004) 600x1200x19mm. Untuk nilai
NRC 0.70, CAC 39, LR 88%, Fire Reaction Class 0/1 based on BS 476 part 6&7
Terms: Minimum order 2,000sqm import from Germany 4 months.

4. Suspension System with earthquake design requirement (point 2.27.2) and Heavy
Duty Load (point 2.27.5)
The specifications we have for the frame: Prelude HD (Heavy Duty) with a size of
24mm(W) x 43mm(H) x 3600mm(L) and BERC2 Clip seismic accessories

All data specifications that we convey are correct and original standards from the
ARMSTRONG factory. We DO NOT make other versions of the above types with
different specifications. This is our explanation, hopefully it can be accepted.