Professional Documents
Culture Documents
Cap Saniter D52 Suthong - Trial (16-11-2021)
Cap Saniter D52 Suthong - Trial (16-11-2021)
Height
Cavity# Sample wall Nozzle of inside hole
(A)
(B) (C) (D)
(A)
(j)
(H) (F)
(E)
(K)
(L)
(D)
Inner
Outer Diameter Width of depth
Diameter of Top width Length of Thickness lock
of bottom the button button
bottom (G) the button (J)
(E) (H) (I)
(F)
(L)
Hole Lock
Leakage
height Stem Vertical Retainer
Weight Test, Other Measurement By
(K) (L) (M)
Blocking
No Out put
T0 Mouldmaker
3.13 3.61 1.12 8.6 OK T0 R&D
2.76 3.37 1.25 T1 Mouldmaker
2.75 3.378 1.24 8.81 OK T1 R&D
T0 Mouldmaker
3.06 3.7 1.13 8.80 OK T0 R&D
2.74 3.39 1.24 T1 Mouldmaker
2.75 3.38 1.24 9.09 OK T1 R&D
T0 Mouldmaker
3.07 3.7 1.17 8.7 OK T0 R&D
2.74 3.38 1.25 T1 Mouldmaker
2.75 3.37 1.23 8.89 OK T1 R&D
T0 Mouldmaker
3.11 3.7 1.14 8.53 OK T0 R&D
2.74 3.39 1.24 T1 Mouldmaker
2.74 3.38 1.24 8.81 OK T1 R&D
Trial Cap Saniter D52
IN LINE
Qty OK
Supplier Can Cap Installed Not Installed
Total
Qty % Qty % Qty %
Trial 300 294 98.0% 300 100.0% 0 ###
UCC
Existing 300 298 99.3% 300 100.0% 0 ###
Trial 300 297 99.0% 300 100.0% 0 ###
UCC
Existing 300 298 99.3% 300 100.0% 0 ###
MMII Trial 300 294 98.0% 300 100.0% 0 ###
Note : Steam valve not centre due to injector too long
Documentation
AFTER SORTER
Steam Valve Functional
Spray Cracked Total Reject
not center test
Qty % Qty % Qty % Qty % Qty %
0 0.0% 0 0.0% 0 0.0% 6 2.0% 6 2.0%
0 0.0% 0 0.0% 2 0.7% 0 0.0% 2 0.7%
0 0.0% 0 0.0% 1 0.3% 2 0.7% 3 1.0%
0 0.0% 0 0.0% 2 0.7% 0 0.0% 2 0.7%
0 0.0% 0 0.0% 1 0.3% 5 1.7% 6 2.0%
Existing