Ts ESP-TM2 en
Ts ESP-TM2 en
Specifications The controller shall have a Seasonal Adjust The controller shall have an electronic
feature to adjust the run time from 5% to diagnostic circuit breaker that can detect if
The ESP-TM2 Controller is a hybrid type 200% in 5% increments. Seasonal Adjust a station has an electrical overload or short
combining electromechanical and micro- shall be capable of being applied to all circuit condition. The controller shall then
electronic circuitry. The controller shall programs simultaneously or to individual bypass the error detected station while
be capable of fully automatic or manual programs. continuing to operate all other stations.
operation. The controller shall be housed
The controller shall have a Delay Watering The controller shall have a reset button to
in a wall-mountable, weather resistant
feature that can override and suspend re-boot the factory default firmware, in
plastic cabinet with lockable door (lock not
programmed watering for up to 14 days. case of controller interface “freezing” due to
included).
The controller shall have a Permanent Days a power surge or interruption of power to
The controller shall have 3 independent the power supply.
Off feature that is available for Odd, Even,
programs that allow 4 different start times
and Cyclic days programming. A day set to The controller shall be upgradable to an
per program. Firmware programming shall
“Permanent Off” shall override the normal EPA WaterSense approved smart controller
automatically stack multiple start times in
repeating schedule. without having to replace the cabinet, nor
sequence to prevent hydraulic overload. All
The controller shall be equipped with disconnect station modules.
programs shall run consecutively.
a variety of Special Features that can The controller shall provide an option for
Watering day schedules shall be: Custom
be accessed by turning the dial to the the installer to run field wires through a
Days of the Week, Odd or Even calendar
appropriate dial position and then pressing ½” or ¾” wire conduit fitting, allowing for a
days and Cyclic (such as every 2 days, or
and holding both the left and right arrow clean, professional installation.
every 3 days, etc.). When the dial is turned
(or back and next) keys simultaneously for The controller shall be compatible with Rain
to the RUN DAYS position, the display shall
3 seconds. Bird’s LNK WiFi Module, allowing wireless
indicate the active schedule type (Odd,
Even, or Cyclic) for the selected program. Special Features shall include: connectivity to the controller.
Station run times shall range from 1 minute • Set Interstation Delay The controller shall be compatible with Rain
to 6 hours. • Reset to Factory Defaults Bird’s LIMR (Landscape Irrigation Mainte-
The controller shall have a 12-hour AM/PM • Rain Sensor Bypass by Station nance Remote) and have a 5-pin accessory
and/or 24 hour mode clock with a midnight port to communicate with Rain Bird ap-
• Save/Restore Programming proved expansion accessories.
day change over. The controller shall have
• Set Master Valve By Station Suggested accessories for use with this
a 365-day calendar backed up against
power interruptions by an internal lithium The controller shall provide the ability to controller:
battery that shall maintain date and time clear all programming and reset to factory • LNK WiFi Module (wireless connectivity)
for approximately 10 years. default settings if desired.
The controller shall provide a method for • Rain Bird RSD Series Rain Sensors
The controller shall offer Manual Watering
options including all stations, any single the operator to save an irrigation schedule • Rain Bird WR2 Wireless Rain/Freeze Sen-
station or any individual program. When into nonvolatile memory for future recall. sors
manual watering is triggered, the unit shall The controller shall be capable of operating • Rain Bird Landscape Irrigation & Mainte-
ignore the status of a rain sensor (if con- one 24VAC solenoid valve per station plus a nance Remote (Available in USA/Canada
nected) and re-enable the sensor when separate master valve or remote pump start Only)
manual watering is completed. relay. • All Rain Bird residential and commercial
The controller shall be capable of bypassing The controller shall operate on 120VAC rotors, valves, nozzles, sprays and drip
a rain sensor (if connected) for each station (±10%) at 60Hz. If connected, a master products
independently. valve or pump start shall operate on 24VAC The ESP-TM2 controller shall be manufac-
at 60Hz. tured by Rain Bird Corporation in a NAFTA
member country.
Rain Bird Corporation Rain Bird Corporation Rain Bird International, Inc.
6991 East Southpoint Road 970 West Sierra Madre Ave. 1000 West Sierra Madre Ave.
Tucson, AZ 85756 Azusa, CA 91702 Azusa, CA 91702
Phone: (520) 741-6100 Phone: (626) 812-3400 Phone: (626) 963-9311
Fax: (520) 741-6522 Fax: (626) 812-3411 Fax: (626) 852-7343
Rain Bird Technical Services Specification Hotline The Intelligent Use of Water TM
(800) RAINBIRD (1-800-724-6247) 1-800-458-3005 (U.S. and Canada) www.rainbird.com
(U.S. and Canada)