Produktdatenblatt | Version 1.1
PLT5 522EA_P
 

PLT5 522EA_P
Metal Can ® TO56
Green Laser Diode in TO56 Package

Applications
——Architecture / Garden Lighting (LED & Laser) ——Mood Lighting
——Area Lights ——Street, Tunnel and Outdoor
——Downlights/Spotlights

Features:
——Optical output power (continuous wave): 20 mW (TC = 25°C)
——Typical emission wavelength: 520 nm
——Efficient radiation source for cw and pulsed operation
——Single mode semiconductor laser
——High modulation bandwidth
——TO56 package with photo diode
DRAFT – For reference only. Subject to change without notice.

Ordering Information 
Type
 Peak output power 
typ.
Popt
Ordering Code

PLT5 522EA_P 20 mW Q65113A2667

1 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Maximum Ratings
TC = 25 °C
Parameter Symbol Values

Operating temperature Top min. -20 °C


max. 60 °C
Storage temperature Tstg min. -40 °C
max. 85 °C
Junction temperature Tj max. 120 °C
Forward current 1) IF max. 200 mA
Reverse voltage 2) VR max. 2V
Soldering temperature TS max. 260 °C
tmax = 10 s

Operation outside these conditions may damage the device. Operation at maximum ratings may influence lifetime.
DRAFT – For reference only. Subject to change without notice.

2 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Characteristics
Popt = 20 mW; Tcase = 25 °C
Parameter Symbol Values

Operating current 1) Iop max. 68 mA


B1 - B3 
Operating current 1) Iop max. 82 mA
B4 - B6 
Operating voltage 3) Vop typ. 5.5 V
max. 6.3 V
Peak wavelength 4) λpeak min. 510 nm
typ. 520 nm
max. 530 nm
Spectral bandwidth (FWHM) ∆λ typ. 2 nm
Beam divergence (FWHM) parallel to pn-junction Θ‖ min. 6°
typ. 8°
max. 10 °
Beam divergence (FWHM) perpendicular to pn-junction Θ┴ min. 19 °
typ. 22 °
max. 25 °
Threshold current Ith typ. 30 mA
max. 50 mA
TE polarization PTE typ. 100:1
Modulation frequency f min. 100 MHz
DRAFT – For reference only. Subject to change without notice.

Monitor current 5)6) Im typ. 150 µA


VR = 5 V


Thermal resistance junction case real RthJC typ. 34 K / W

3 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Wavelength Groups 
Iopt <= 68 mA: B1 - B3; Iopt = 68 mA - 82 mA: B4 - B6 

Group Peak wavelength 7) Peak wavelength 7)


min. max.
λpeak λpeak

B1 510 nm 515 nm
B4 510 nm 515 nm
B2 515 nm 520 nm
B5 515 nm 520 nm
B3 520 nm 530 nm
B6 520 nm 530 nm

Relative Spectral Emission 8), 9)

Ie,rel = f (λ); IF = 65 mA; Popt = 20 mW


DRAFT – For reference only. Subject to change without notice.

4 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Beam Divergence 8), 9)

Popt = f (Θ)

Optical Output Power 8), 9) Opt. Power / Forward Voltage 8), 9)

Popt = f (IF) VF = f (IF)
DRAFT – For reference only. Subject to change without notice.

5 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Threshold Current
Ith = f(TC)
DRAFT – For reference only. Subject to change without notice.

6 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Dimensional Drawing 10)

Further Information:
Approximate Weight: 310.0 mg

ESD advice: ATTENTION – Observe Precautions For Handling – Electrostatic Sensitive


Device
DRAFT – For reference only. Subject to change without notice.

7 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Electrical Internal Circuit

Pin Description

PIN1 LD Cathode
PIN 2 LD Anode, PD Cathode (case)
PIN 3 PD Anode
DRAFT – For reference only. Subject to change without notice.

8 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Tray 10)

200 pieces per Tray

Barcode-Product-Label (BPL)
DRAFT – For reference only. Subject to change without notice.

9 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Dry Packing Process and Materials


Moisture-sensitive label or print

N s E RS
L
E

re
V
E

tiv
L

e
la ared ag
fr
in pa
If

hu

ck
an

m
e be

k,
bl r co
ba
id

e
de

ity
l
sela

30
(R
H

˚C
).

/6
0%
R
H
.
Barcode label
TIO
<
_
in IV O % k
IT T of
nta
90 to rs
S C < d ea s ). rs
N U ou
U coSEND d te (p on ,
or de H rs
iti ou
an bjec ng ou rs
Ais bUagRMEICO ˚C co 72 H
si nd 5 H ou
˚C su es te 48
CThIS co ± e H
y da e 24 6
T E 40 be oc
or ˚C tim e
S < ill pr). ith or tim
O w nt ct 23 w tim e
M TO
at fa lo or
s at le ˚C at at e. al F lo or tim
P th th va l tic F lo or
O on s ui be if: read
ur F lo
m ce eq la lo
w ed
id
en l 4 5 F
vi g, n oc ve l
24 or de be in pr is 5a
de , e nt whe Le ve l 6
te
g: , w
r
co
se ou ke e Le ve l
da Le ve
ba ed flo
ba e m % ba al st
ur e
ed en re e 10 r ur e Le
re oi st ur e
al op e se
tim
fo >
fo se
M oi st ur
se is as or . is 33 k, M oi st
k, lo H bed
in g ph , -0 an M oi
e r- an in F R ng ar D bl M
ba
lif is po If bl ith % ki r C. S
T (if r
lf th va p. w 10 ba to et J- ea r ks
he r w, m <
_ m Y ea rs
S fte
te
nt
ed
at iredicat d, EC 1 Y ee
ou
A flody qu In no ire D > 1 W
1.
re ou d
reity is qu/JE
e 4 8 H
2. bo M re e
to es id 2b re C : tim e 16
a) S ic is IP or tim
b) ev Humor e
ed
lo or tim e
en F
D 2a king nc te F
lo or tim
a) op lo
3. b) ba re da e F loor
If fe
al l 1 2 F
re tim ve l
4. se d l 2a
Le ve 3
ag an e Le ve l
B e ur e Le ve
at st ur e
D Le
oi st ur e
M oi st ur
M oi st
M oi
M

M
RA
OS

Humidity indicator
Barcode label
Do not eat.
Avoid metal contact.
Discard if circles overrun.
bag opening.
Please check the HIC immidiately after

check dot WET


Comparator

bake units
examine units, if necessary 15%
If wet,

bake units
examine units, if necessary 10%
If wet,

change desiccant
parts still adequately dry. 5%
If wet,

MIL-I-8835
Humidity Indicator

Desiccant
AM
OSR

OHA00539

Schematic Transportation Box 10)

Box
DRAFT – For reference only. Subject to change without notice.

 Barcode label
ML : 1- 20
n3 : Q- 1-

20
Bi n2 : P-
D Bi Bin1

24 0 ST
Muster Ad 26 0 C R
22 mp

MY
P 76

ion C R
Te

PA 77 al RT
0 C

DE
T6

XT
LE

TE
ti Y

2
ul LS

18
2a
TO

-1
R
3

R0 dit

+Q
R:
VA

-1
M

CK

P
P:
OU
GR
)
(G

8
2199
44
01
ct pto

2100
s

C:
or

D/
du O

D)
ic AM

(9

00
on
em R

34

20
:
NO
S S

12
O

:
TY
H

H
TC

)Q

5
3G
BA

(Q

14 2
: 12
P)
(6

110 0
NO
T
LO
T)
(1

:
NO
OD
PR
)
(X

Original packing label


OHA02886

10 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Dimensions of Transportation Box


Width Length Height

215 ± 5 mm 265 ± 5 mm 95 ± 5 mm
DRAFT – For reference only. Subject to change without notice.

11 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Notes
Depending on the mode of operation, these devices emit highly concentrated visible and non visible light
which can be hazardous to the human eye. Products which incorporate these devices have to follow the
safety precautions given in IEC 60825-1.
Subcomponents of this device contain, in addition to other substances, metal filled materials including silver.
Metal filled materials can be affected by environments that contain traces of aggressive substances. There-
fore, we recommend that customers minimize device exposure to aggressive substances during storage,
production, and use. Devices that showed visible discoloration when tested using the described tests above
did show no performance deviations within failure limits during the stated test duration. Respective failure
limits are described in the IEC60810.
For further application related information please visit www.osram-os.com/appnotes
DRAFT – For reference only. Subject to change without notice.

12 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Disclaimer

OSRAM OS assumes no liability whatsoever for any use of this document or its content by recipient includ-
ing, but not limited to, for any design in activities based on this preliminary draft version. OSRAM OS may
e.g. decide at its sole discretion to stop developing and/or finalising the underlying design at any time.

Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may
contain dangerous substances.
For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version on the OSRAM OS website.

Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest
sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of
transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we
shall have to invoice you for any costs incurred.

Product and functional safety devices/applications or medical devices/applications


OSRAM OS components are not developed, constructed or tested for the application as safety relevant
component or for the application in medical devices.
OSRAM OS products are not qualified at module and system level for such application.

In case buyer – or customer supplied by buyer – considers using OSRAM OS components in product safety
devices/applications or medical devices/applications, buyer and/or customer has to inform the local sales
partner of OSRAM OS immediately and OSRAM OS and buyer and /or customer will analyze and coordi-
nate the customer-specific request between OSRAM OS and buyer and/or customer.
DRAFT – For reference only. Subject to change without notice.

13 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Glossary
1)
Operating/Forward current: IF is measured with an internal reproducibility of ±7 % (acc. to GUM with a
coverage factor of k = 3).
2)
Reverse Operation: This product is intended to be operated applying a forward current within the
specified range. Applying any continuous reverse bias or forward bias below the voltage range of light
emission shall be avoided because it may cause migration which can change the electro-optical char-
acteristics or damage the LED.
3)
Operating/Forward voltage: VF is measured with an internal reproducibility of ±0.05 V (acc. to GUM
with a coverage factor of k = 3).
4)
Wavelength: λpeak is measured with an internal reproducibility of ±0.3 nm (acc. to GUM with a cover-
age factor of k = 3).
5)
Monitor current: Monitor current refers to a reverse voltage of VRPD = 5 V. Monitor current is for short
time power reference purpose only. Not guaranteed for accuracy.
6)
Monitor current: For reference only.
7)
Wavelength: The wavelengths are measured with a tolerance of ±1 nm.
8)
Typical Values: Due to the special conditions of the manufacturing processes of semiconductor devic-
es, the typical data or calculated correlations of technical parameters can only reflect statistical figures.
These do not necessarily correspond to the actual parameters of each single product, which could dif-
fer from the typical data and calculated correlations or the typical characteristic line. If requested, e.g.
because of technical improvements, these typ. data will be changed without any further notice.
9)
Testing temperature: TA = 25°C (unless otherwise specified)
10)
Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and
dimensions are specified in mm.
DRAFT – For reference only. Subject to change without notice.

14 Version α.2 | 2021-02-02


PLT5 522EA_P
 

Revision History
Version Date Change

α.2 2021-02-02 Characteristics


Wavelength Groups
α.2 2021-02-02 Characteristics
Wavelength Groups
DRAFT – For reference only. Subject to change without notice.

15 Version α.2 | 2021-02-02


PLT5 522EA_P
 
DRAFT – For reference only. Subject to change without notice.

Published by OSRAM Opto Semiconductors GmbH


Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.

16 Version α.2 | 2021-02-02