Indicators
SMCS - 6700-IND
The indicators show the status of certain functions of the auxiliary hydraulic ECM.
Indicator (hydraulic lockout) and interlock override connect to contact 3 and contact 5
Illustration 2 g01033983
Location of the Indicator for the hydraulic lockout and interlock override
The indicator for each function is located in the warning indicator module in the right headliner.
The indicator for the hydraulic lockout shows the operator that the hydraulic lockout is enabled. If the
hydraulic lockout is enabled, the hydraulics are locked out and the indicator is illuminated. The
normally open set of contacts in the lockout switch and the door switch activate the indicator.
The interlock override indicator shows the operator when the interlock override function is enabled.
The auxiliary hydraulic ECM sends a signal to the indicator when the interlock override function is
enabled.