Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Manual for EMRAX Motors / Generators | Version 5.

4 | 5th of March 2020

EMRAX 188 Technical Data Table


Type
EMRAX 188 EMRAX 188 EMRAX 188
High Voltage Medium Voltage Low Voltage
Technical data
Air cooled = AC
Liquid cooled = LC
AC LC CC AC LC CC AC LC CC
Combined cooled = Air + Liquid cooled =
CC
Ingress protection IP21 IP65 IP21 IP21 IP65 IP21 IP21 IP65 IP21
Cooling medium specification
(Air Flow = AF; Inlet Water/glycol Flow =
WF=8l/min WF=8l/min WF=8l/min WF=8l/min WF=8l/min WF=8l/min
WF; Ambient Air = AA) AF=20m/s; AF=20m/s; AF=20m/s;
at 50°C; at 50°C; at 50°C; at 50°C; at 50°C; at 50°C;
If inlet WF temperature and/or AA AA=25°C AA=25°C AA=25°C
AA=25°C AA=25°C AA=25°C AA=25°C AA=25°C AA=25°C
temperature are lower, then continuous
power is higher.
Weight [kg] 7,0 7,3 7,2 7,0 7,3 7,2 7,0 7,3 7,2
Diameter ø / width [mm] 188 / 77
Maximal battery voltage [Vdc] and max
430 Vdc (6500 RPM) 300 Vdc (6500 RPM) 110 Vdc (6500 RPM)
load RPM
Peak motor power at max load RPM
(few min at cold start / few seconds at 52
hot start) [kW]

Continuous motor power (at 6500 RPM) 23 25 29 23 25 29 23 25 29

Maximal rotation speed [RPM] 6500 (8000 for a few seconds with magnetic field weakening)
Maximal motor current (for 2 min if
200 300 800
cooled as described in Manual) [Arms]
Continuous motor current [Arms] 100 150 400
Maximal peak motor torque [Nm] 90
Continuous motor torque [Nm] 40 43 50 40 43 50 40 43 50
Torque / motor current [Nm/1Aph rms] 0,60 0,39 0,15
Maximal temperature of the copper
windings in the stator and max. 120
temperature of the magnets [°C]
Motor efficiency [%] 92-98%
Internal phase resistance at 25 °C [mΩ] 12,0 5,0 0,8
Input phase wire cross-section [mm2] 10,2 15,2 38,0
Wire connection star
Induction Ld/Lq [µH] of 1 phase 92/102 40/44 5,4/6,0
Controller / motor signal sine wave
AC voltage between two phases
0,0384 0,0252 0,00923
[Vrms/1RPM]
Specific idle speed (no load) [RPM/1Vdc] 19 28 75
Specific load speed (max load)
15 22 60
[RPM/1Vdc]
Magnetic field weakening (for higher
RPM at the same power and lower up to 100
torque) [%]
Magnetic flux – axial [Vs] 0,033 0,022 0,008
Temperature sensor on the stator
kty 81/210
windings
Number of pole pairs 10
Rotor Inertia_ LC motor [kg*m²] 0,0134
Bearings (front:back) - FAG 6204:3204 (for axial-radial forces; for pull-push mode, α=25°)
Manual for EMRAX Motors / Generators | Version 5.4 | 5th of March 2020

Graphs valid for EMRAX 188:


Manual for EMRAX Motors / Generators | Version 5.4 | 5th of March 2020

Graphs of EMRAX air cooled and liquid cooled type:


The continuous power and continuous torque for air cooled motor is 20% lower and for liquid cooled motor is 15% lower.

Graphs of the EMRAX 188 medium and low voltage motor type:
Graphs of EMRAX 188 low voltage and EMRAX 188 medium voltage are similar to graphs of EMRAX 188 high voltage. The
only differences are the DC voltage and motor current. These two parameters can be read from the Technical data table
for the EMRAX 188 low and medium voltage motor.
Low voltage motor needs 4 x higher motor current and 4 x lower DC voltage for the same power/torque and RPM,
compared to EMRAX 188 high voltage motor.
Medium voltage motor needs 1.52 x higher motor current and 1/3 lower DC voltage for the same power/torque and RPM,
compared to EMRAX 188 high voltage motor.