KG125W KG125WS

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

KG125W / KG125WS

Diesel Generating Set Output Ratings

Prime Rating at Standby Rating at


Model Phase / Volts / Hz
0.8 pf (lag) 0.8 pf (lag)

KG125W (OPEN)
125 kVA 138 kVA
3 Phase / 380 V / 50 Hz
100 kW 110 kW
KG125WS (SAE)

 SAE – Sound Attenuated Enclosure


 Ratings are according to ISO 8528; refer to ratings definition on page 2.

KG125W KG125WS

Note: Above picture shown for illustration purpose only, actual product may be different.

Features

 Extremely reliable.
 Lower operating cost.
 Easy maintenance – higher uptime.
 Sound attenuating enclosure (canopy) is fully integrated and designed for all weather
conditions (weather proof).
 Best in class Sound attenuation – 75 dB(A) at one meter as per ISO 8528
 State of the art generating set control system with high degree of accuracy and reliability.
 Ideally suitable for critical industries like Construction, Manufacturing, Textile, Telecom,
Services etc.
 Superior design standards that minimize power deration even at high ambient temperatures.
 Efficient and prompt after sales service available.
 Winner of the frost & Sullivan Voice of Customer Award in the “Best Bang for Buck”
category in the Indian Generating sets Market.

Power, Performance, Peace of Mind.


Ratings Definition:

Standby Ratings:

These ratings are applicable for supplying continuous electrical power (at variable load) in the event
of a utility power failure. No overload is permitted on these ratings. The alternator on this model is
peak continuous rated (as defined in ISO 8528-3)

Prime Rating:

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of
commercial purchased power. There is no limitation to the annual hours of operation and this model
can supply 10% overload power for 1 hour in 12 hours.

Continuous Rating:

These ratings are applicable for supplying power continuously to a constant load upto the full output
rating for unlimited hours. No sustained overload capability is available for this rating.

GENERATING SET SPECIFICATIONS CONTROL SYSTEM


Model - Open Type KG125W Controller Make Deepsea
Model - SAE Type KG125WS Controller Model DSE 6122
Frequency (Hz) 50 Generator Voltage
Generator Amps
Power Factor 0.8 Generator Frequency
Phase Three phase Mains Voltage
Digital display
Battery Voltage
instrumentation
Line Voltage (Volts) 380 Engine hours Run
Oil Pressure Gauge
Phase Voltage (Volts) 220 Engine Temperature Gauge
Open – 200 Fuel Level
Fuel Tank Capacity (Liters) Fail to Stop
SAE – 260 Low Oil pressure
Fuel consumption at 100% High Engine Temperature
29.18 Under/Over-speed
load (lit/hr) +5% tolerance
Fuel consumption at 75% Under/Over voltage
21.89 Shutdowns/Safeties
load (lit/hr) +5% tolerance Emergency Stop
Sound level at 1 m for Silent Failed to reach loading voltage
75 Failed to reach loading frequency
Generating set dB(A)
Charge Fail
Open - 282x140x215 Over Current Low DC Voltage
Overall dimensions (cms) Automatic Starting &
SAE – 450x200x245 Available
AMF facility
Open Type – 1640
Weight (kgs)
SAE Type – 3280

Power, Performance, Peace of Mind.


Engine Technical Data

Physical Data Fuel System


Engine Make Kirloskar Type of fuel filter Two stage spin on type
Engine Model 6R1080TA Governor Type Mechanical
Number of cylinders 6 ISO 3046 Class A1 &
Class of Governing
ISO 8528-5, Class G2
Configuration Inline
Type Four stroke Fuel pump type Inline

Bore x Stroke (mm) 105 x 125 Fuel pump make MICO - BOSCH
Class A2,
Displacement (cc) 6480 Recommended Fuel
High speed diesel
Cooling Water cooled Fuel consumption at 100%
29.18
load (lit/hr) +5% tolerance
Turbocharged
Aspiration Fuel consumption at 75%
Aftercooled 21.89
load (lit/hr) +5% tolerance
Compression Ratio 14.5 : 1 Fuel consumption readings are based on diesel fuel
Starting Arrangement 12V Electric with a specific gravity of 0.85 and confirming to BS
2869, Class A2)

Air System Lubrication System

Dry type replaceable


Air Filter Type Type of lube oil filter Full flow spin on type
element
Air Volume required for
10614 Oil to be used Multi grade 15W40
Ventilation (m³/hr)
Through G-rotor gear
Combustion air flow (m³/hr) 292 Oil pump type
pump
Total Air Flow required for
11327 Lub oil sump capacity (lit) 13.5
ventilation (m³/hr)
Total Fresh air required 0.3% of fuel
18705 Lube oil consumption
(m³/hr) consumption

Cooling System Electrical System

Cooling system capacity (lit) 39 Starting Arrangement 12V Electric

Starter 12V Electric


Water pump type Centrifugal

Starter Battery Rating 150


Radiator fan load (hp) 6.5
Engine mounted 12V
Battery charging alternator
battery charger
Battery charger amps 35

Power, Performance, Peace of Mind.


Alternator Technical Data
Physical Data
Operating Data
Manufacturer Stamford
Over speed (RPM) 2250
Model UC274E
Excitation Self excited
Number of bearings 1
Efficiency (%) 91.30
Insulation class H Total harmonic distortion at
Less than 5%
Winding pitch 2/3 full load AC waveform
Voltage Regulation (%) ± 1.0
Wires 12
Reactance per unit (Xd) 2.34
Ingress Protection Rating IP 23
Reactance per unit (X’d) 0.21
AVR Model SX 460 Reactance per unit (X’’d) 0.14

Sound Attenuating Enclosure (Canopy) General Data

 A full set of Illustrated


Sound Level 75 dB(A) at 1 meter as per ISO 8528
spare parts catalogue
 Fully Integrated, metal construction Documents  Operation &
for ALL WEATHER USE (weather Maintenance manual
proof).  Circuit Diagrams
 Black zinc die cast, Aluminium hinges ISO 8528, ISO 3046, IS
or Stainless steel hinges tested to Quality
100002, BS5514, DIN 6271,
withstand corrosive environment Standards
ISO 9001, ISO 14001
Construction conditions.
 Fuel filling spout with lock.
 Emergency stop button on canopy
exterior.
 Provision of glass window for viewing
control panel
 Provision for lifting canopy
Easy access through lockable doors for
Maintenance operation/maintenance and repair works
(including access for radiator service)

Protection
IP 23 Standard
Standard

KIRLOSKAR OIL ENGINES LIMITED.


Head Office:
Laxmanrao Kirloskar Road, Khadki, Pune 411 003, India.
Tel.: +91 20 2581 0341 / 534 Fax: +91 20 2581 3208 www.kirloskar.com

Shailendra.halbe@kirloskar.com
H/p : +62 818 222214 (Indonesia)

Kirloskar Oil Engines Limited reserved the right to change the design or specifications without notice.
Contact your local distributor for more details.

Power, Performance, Peace of Mind.