Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

PROJECT NAME:_________________

ELEMENT 1.7b
STACKING AND STORAGE INSPECTION

Area/ Location Store Inspection No.

Inspector Name Date of Inspection

RAISE THE ISSUES THROUGH CORRECTION REPORT (BEFORE & AFTER PHOTO) FOR ACTION TAKEN
Observation &
No Item Description & Reference Yes No N/A Remarks
Recommendation
ELECTROMECHANICAL STORE
Is base uneven and unable to sustain weight
1 exerted by stack ?
2 Are stacking neat and arranged ?
3 Are stacking free from hazardous materials?
Are articles consistently of the same size, shape
4 and mass ?
5 Are storage areas demarcated ?
6 Are pallets and containers in good condition ?
7 Is support structure properly installed ?
8 Are stacks in danger of collapsing ?
9 Are Stored items clearly identified and labelled ?
10 Are staking over cabinets and windows sills?
Is staking height as per standard (3 times base
11 width) ?
12 Is stack heights displayed ?
13 Is safe access and egress provided ?
Is appropriate ladder or lift provided to gain
14 access to stacks ?
Stack does not obstruct power source, firefighting
15 equipment, lighting, ventilation, sprinkler or
detectors (minimum 1m clearance).
CHEMICAL & FLAMMABLE MATERIALS STORE
Are all chemical stored according to SDS and
1 compatibility table ?
Are stores equipped with proper ventilation and
2 lighting systems ?
Is clear indication provided outside or entrance
3 door of the chemical store?
Are all chemical & flammable liquids stored in a
4 metal cupboard ?
Are the store is equipped with doors and gauzed
5 ventilation holes ?
6 Are all flammable items clearly labelled?
Are all flammable liquid stored separately
7 without combustible packing materials like
wood, rags, carton boxes, etc. ?
Are appropriate signages posted like "No open
8 flames" and "No smoking" in the chemical store ?
Are Sufficient numbers of the correct fire-
9 fighting equipment (fire extinguisher, smoke
detectors, etc.) available in the chemical store ?
Are all MSDS, emergency and first aid
10 instructions available at store ?
COMPRESSED GAS CYLINDER STORE
1 Is clear indication provided outside or entrance
Page 1 of 2 Rev.2 [08-April-2019] Projects Business Unit
door of the store?
Are the store is equipped with doors and gauzed
2
ventilation holes ?
Are stores equipped with proper ventilation
3
equipments and lighting ?
Are all cylinders, stored, securely in an upright
4 (vertical) position and fixed with clamps and
chains?
5 Are all gas cylinder clearly labelled ?
Are appropriate signages posted like "No open
6
flames" and "No smoking" in the store ?
Are Oxygen and acetylene gas cylinders
7
separately stored for minimum 20 feet (6.5 m) ?
Are empty compressed gas cylinders stored
8
separately from filled one ?
Are all MSDS, emergency and first aid
9
instructions available at store ?
OUTDOOR STORAGE
1 Are the storage area demarcated as per standard ?
Are all items properly stacked, organized and
2
maintained the 1:3 ratio base dimension?
Is stack yard located in high level area ,free from
3
rain-water accumulation?
4 Is stack yard provided with adequate lighting?
Are stacked materials protected with adequate
5 protection from atmospheric conditions &
adverse weather?
Is appropriate access and egress provided for
6
pedestrian and equipments?
Are Sufficient numbers of the correct fire-
7 fighting equipment (fire extinguisher) available in
the stack yard ?

Inspector Name: __________________________ Signature: _________________ Date: _______________

Safety Engineer Name: ______________________ Signature: _________________ Date: _______________

Site Manager Name: ______________________ Signature: _________________ Date: _______________

Page 2 of 2 Rev.2 [08-April-2019] Projects Business Unit