PART-1 : Valves
2. The cage in the following drawing is used in the valve with characteristic :
3. In control valves, when the pressure at the vena contracta drops below vapor
pressure of the fluid and then rises again at the valve downstream, the phenomena
is called :
A. Flashing
B. Corrosion
C. Cavitation
D. Both B and C
4. The smooth polished appearance of the eroded trim in control valves is due to :
A. Flashing
B. Corrosion
C. Cavitation
D. Both B and C
8. When catalityc gas detector is used to detect gas leakage from vessel handling
methane :
A. Detector is located 2 meters away from the vessel
B. Detector should be installed at the bottom of the vessel
C. Detector should be installed at the top of the vessel
D. Detector should be installed inside the vessel
10. This circuit is used in Fire Detection System, what is the use of R1 & R2?
A. R1 to differentiate between cable cut and fire detection while R2 to differentiate
between short circuit and fire detection
B. R1 to differentiate between short circuit & fire detection while R2 to
differentiate between cable cut and fire detection
C. R1 to differentiate between cable cut and normal operation while R2 between
short circuit and fire detection
D. R1 to differentiate between short circuit and normal operation while R2 to
differentiate between cable and normal operation
PART-3 : Instrumentation
17. When measuring flow with orrifice plate and a differential pressure transmitter :
A. Flow = K x ΔP
B. Flow is proportional to square root is ΔP
C. Flow is proportional to square of ΔP
D. Flow is equal to ΔP
20. The formula describing behafior of gas under varying physical conditions is :
A. Rt = Ro (1 + α t)
B. PV = kT
C. ΔP * Vx = log T
D. P*T = R
PART-4 : Vibration
22. The proximitor module feeding the sensor in a Bently Nevada 3300 system is
supplied by :
A. 220 VAC
B. 24 VDC
C. -24 VDC
D. -12 VDC
23. The keyphasor module is used to measure :
A. Shaft Vibration
B. Shaft Rotative Speed
C. Shaft Axial Displacement
D. Gear Temperature
24. Sensitivity of the Proximity module can be :
A. 3.9 V/m
B. 3.9 µV/mm
C. 3.9 µV/mm
D. 3.9 µV/µm
25. In order to measure the vibration of the machine casing we used :
A. Velocity Monitor
B. Vibration Monitor
C. Axial Displacement Monitor
D. Speed Monitor
29. Three shut off valves are in series, this system is considered :
A. 1oo2
B. 3oo3
C. 2oo3
D. 1oo3
30. One pressure switch is connected to three PLC input cards, this system is considered :
A. 1oo2
B. 1oo1
C. 1oo3
D. 2oo3