Specification: DS-1…..Cat 3-5 4th Edition & Oilserv specification Min Black light Intensity : 2984 µW/cm2
Inspection method: MPI (Fluorescent Mag) and White & Black Ink Min Visible Light : 500 Lux
Equipment used: AC Yoke: DC Coil: Setting test ml/100ml: 2
UV Light: UV Meter: Coil A/T: 14300
Total Tools Inspected : 25 Comment : Visual and MPI performed on body & thread and No Defect observed at Time of Total Tools For Repair : 00
Results Total Tools Scrapped : 00
Total Tools Accepted : 25 observed at Time of inspection (OK)
04 Housing Belleville Spring and 04 Mandrel Belleville Spring was inspected MPI full body
Inspected By : Approved By :
TD=Thread Damage SD=Shoulder Damage GT=Galled Thread CORR=Corrosion ST=Streched Thread CR=Cracke BB=Belled Box OT=Over Torque
PRO=Worn Profile DIM=Dimensional WO=Wash Out OS=Over Size US=Under Size ECC=Eccentric Wear