Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

EURL OSCO Oil Services Company IMP-OSCO-OP-07

Adresse: B,P 04 Hassi Messaoud-Ouargla


Version : A
Tel : +213 (0)29 79 79 79 Fax : +213 (0)29 79 79 70
E-mail : contact@osco-oil,com Page : 1/1

MUD MOTOR INSPECTION REPORT


Customer: OILSERV Certif N°: NDT/MT/VT 00580 010
Work Location: Hassi Messaoud Issue Date : 10/10/2021
Work Order: 00580 Due Date : 09/04/2022

Specification: DS-1…..Cat 3-5 4th Edition & Oilserv specification Min Black light Intensity : 2984 µW/cm2
Inspection method: MPI (Fluorescent Mag) and White & Black Ink Min Visible Light : 500 Lux
Equipment used: AC Yoke: DC Coil: Setting test ml/100ml: 2
UV Light: UV Meter: Coil A/T: 14300

TOOL DESCRIPTION: 4 3/4 MUD MOTOR (MMO-MBTB) SN:

CONN ROTOR STATOR CONN


COND COND
OD OD
ID ID
Leng TENSIONING NUT Leng

CONN END CAP WITH SLEEV UNIVERSAL CAP CONN


COND COND
OD OD
ID ID
Leng Leng

CONN DRIVE SHAFT ROTOR CATCH PLUG CONN


COND COND
OD OD
ID ID
Leng Leng

CONN A-BENT SUB A-BENT MANDREL CONN


COND COND
OD OD
ID ID
Leng Leng

CONN B-DRIVE CONECTOR BEARING HOUSING W-SLEEV CONN


COND COND
OD OD
ID ID
Leng Leng

CONN ROTOR ADAPTOR BEARING MANDREL CONN


COND COND
OD OD
ID ID
Leng Leng

CONN THREAD PROTECTOR ROTOR CATCH MANDREL CONN


COND COND
OD OD
ID ID
Leng Leng

CONN DUMP SUB BODY STATOR HOUSING ADAPTOR CONN


COND COND
OD OD
ID ID
Leng Leng

Total Tools Inspected : 25 Comment : Visual and MPI performed on body & thread and No Defect observed at Time of Total Tools For Repair : 00
Results Total Tools Scrapped : 00
Total Tools Accepted : 25 observed at Time of inspection (OK)
04 Housing Belleville Spring and 04 Mandrel Belleville Spring was inspected MPI full body
Inspected By : Approved By :

TD=Thread Damage SD=Shoulder Damage GT=Galled Thread CORR=Corrosion ST=Streched Thread CR=Cracke BB=Belled Box OT=Over Torque
PRO=Worn Profile DIM=Dimensional WO=Wash Out OS=Over Size US=Under Size ECC=Eccentric Wear