Professional Documents
Culture Documents
14PHY036 - CPumpCatalog - September 2014
14PHY036 - CPumpCatalog - September 2014
Contents
General Information..................................................................................................................................................................... 1
Model Codes................................................................................................................................................................................. 2
Technical Data.............................................................................................................................................................................. 6
Efficiency Information.................................................................................................................................................................. 8
C055.................................................................................................................................................................................... 8
C081.................................................................................................................................................................................... 9
C136.................................................................................................................................................................................. 10
Controls....................................................................................................................................................................................... 11
Manual Lever Control With Feedback – A......................................................................................................................... 11
Hydraulic Proportional Control With Feedback – C ......................................................................................................... 13
Hydraulic Proportional Control Without Feedback – D..................................................................................................... 15
Electric Non-Proportional – E............................................................................................................................................ 17
Electric Proportional Control With Feedback – F ............................................................................................................. 19
Electric Proportional Control Without Feedback – G........................................................................................................ 22
Electric Proportional Control With Hydraulic Emergency Override – H............................................................................. 25
Automotive – J/K............................................................................................................................................................... 28
Pressure Override Options........................................................................................................................................................ 30
Pressure Override – P........................................................................................................................................................ 30
Electric Cut-Off Valve – E.................................................................................................................................................. 31
Electrical Cut-Off Valve and Pressure................................................................................................................................ 32
Charge Filtration Options.......................................................................................................................................................... 33
Remote Charge Filtration – R............................................................................................................................................ 35
Dimensions – C55....................................................................................................................................................................... 37
Pump and Controls............................................................................................................................................................ 37
Shaft.................................................................................................................................................................................. 41
Through Drives.................................................................................................................................................................. 42
Dimensions – C081..................................................................................................................................................................... 44
Pump and Controls............................................................................................................................................................ 44
Shaft ................................................................................................................................................................................. 50
Pump and Accessories...................................................................................................................................................... 51
Through Drives.................................................................................................................................................................. 54
Dimensions – C136..................................................................................................................................................................... 56
Pump and Controls............................................................................................................................................................ 56
Shaft ................................................................................................................................................................................. 60
Pump and Accessories...................................................................................................................................................... 61
Through Drives.................................................................................................................................................................. 62
Installation Information.............................................................................................................................................................. 66
Offer Of Sale................................................................................................................................................................................ 69
Notes ........................................................................................................................................................................................... 70
Revisions..................................................................................................................................................................................... 71
Offer of Sale
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor.
This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” elsewhere in this document.
General Information
C Series variable displacement piston pumps have
been designed for use in closed circuit hydrostatic
applications. The flow direction is controlled by a
rugged swash plate and bearing design. Units are rated
to operate at pressure up to 420 bar (6090 PSI).
Pump Mount Input Charge Control B Side Cross Pressure Charge Through B Side
Series and Port Shaft Pump Modifier Port Relief Override Filtration Drive Displacement
Displacement Rotation Displacement A Side Cross Charge Relief Override A Side Options
Control Port Relief Setting Options Displacement
136 136 cc/rev (8.3 CIR) A 18 cc/rev (1.1 CIR) # # — F Electric proportional with internal feedback
Pump Mount Input Charge Control B Side Cross Pressure Charge Through B Side
Series and Port Shaft Pump Modifier Port Relief Override Filtration Drive Displacement
Displacement Rotation Displacement A Side Cross Charge Relief Override A Side Options
Control Port Relief Setting Options Displacement
— — X — — — — — — <-> 0 0 5 0.5 mm (.019 in) Control orifice C 420 Bar (6090 PSI)
— X X — — — — — — <-> 0 0 6 0.6 mm (.024 in) Control orifice D 450 Bar (6525 PSI)
— — — — X — — — — <-> 2 0 7 12 VDC, 0.7 mm (.027 in) Control orifice Charge Relief Setting 055 081 136
— — — — # X X — — <-> 2 0 8 12 VDC, 0.8 mm (.031 in) Control orifice A 20 Bar (290 PSI) X X —
— — — X X — — — — <-> 2 1 2 12 VDC, 1.2 mm (.047 in) Control orifice B 22 Bar (319 PSI) # # #
— — — — X — — — — <-> 2 2 0 12 VDC, 2.0 mm (.079 in) Control orifice C 25 Bar (362 PSI) X X X
— — — — X — — — — <-> 4 0 0 24 VDC, No control orifice # = Standard option
X = Available
— — — — X — — — — <-> 4 0 6 24 VDC, 0.6 mm (.024 in) Control orifice
— = Not available
— — — — X — — — — <-> 4 0 7 24 VDC, 0.7 mm (.027 in) Control orifice
Pump Mount Input Charge Control B Side Cross Pressure Charge Through B Side
Series and Port Shaft Pump Modifier Port Relief Override Filtration Drive Displacement
Displacement Rotation Displacement A Side Cross Charge Relief Override A Side Options
Control Port Relief Setting Options Displacement
Pump Mount Input Charge Control B Side Cross Pressure Charge Through B Side
Series and Port Shaft Pump Modifier Port Relief Override Filtration Drive Displacement
Displacement Rotation Displacement A Side Cross Charge Relief Override A Side Options
Control Port Relief Setting Options Displacement
Charge Filtration 055 081 136 A Side Displacement Options 055 081 136
*Peak is defined as no longer than 1% of every minute. For long life, design
system to not run at maximum flow and pressure continuously.
% Efficient
% Efficient
96 85
95 80
94 75
1000 RPM 1000 RPM
93
1600 RPM 70 1600 RPM
92 2200 RPM 2200 RPM
91 3000 RPM
65 3000 RPM
90 60
100 150 200 250 300 350 100 150 200 250 300 350
Pump Outlet Pressure (Bar) Pump Outlet Pressure (Bar)
85
80
75 1000 RPM
70 1600 RPM
2200 RPM
65 3000 RPM
60
100 150 200 250 300 350
Pump Outlet Pressure (Bar)
96
Kw
95 60
94
93 1000 RPM 40
92 1600 RPM
2200 RPM 20
91
90 0
100 150 200 250 300 350 100 150 200 250 300 350
Pump Outlet Pressure (Bar) Pump Outlet Pressure (Bar)
% Efficient
85 85
80 80
75 75
70 70
65 65
60 60
100 150 200 250 300 350 100 150 200 250 300 350
96 120
95 100
Kw
94 80
93 1000 RPM
60
92 1600 RPM
40
2200 RPM
91 20
90 0
100 150 200 250 300 350 100 150 200 250 300 350
Pump Outlet Pressure (Bar) Pump Outlet Pressure (Bar)
% Efficient
85 85
80 80
75 75
1000 RPM
1000 RPM
70 1600 RPM 70 1600 RPM
65 2200 RPM
65 2200 RPM
60 60
100 150 200 250 300 350 100 150 200 250 300 350
Pump Outlet Pressure (Bar) Pump Outlet Pressure (Bar)
Testing completed using ISO VG68 fluid at 90°C 23 cc charge pump
with 22 bar pressure setting
A C
C055 Lever Angle vs. Displacement
40 20 [290]
16 [232] /re
v]
30 m
3
c
v] [55
/re 12 [174] rev
n/
3 3
20 c m 5i
[55 3.3
rev 8 [116]
n/
3
5i
0
0
-10 v]
3
/re -4 [-58]
cm
55
-20 v[
3
n /re -8 [-116]
5i v]
3.3 3
/re
m
-30 -12 [-174] 5 5c
v[
n
3
/re
5i
-40 -16 [-232] 3.3
-100 -80 -60 -40 -20 0 20 40 60 80 100
-20 [-290]
Displacement (%) -100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
C081 Lever Angle vs. Displacement
40
30
v]
3
/re
c m
20 [81
rev PS T GS GA
n/
3
4i
4.9 Z1
10 V1
Z2 A
Angle (°)
0 V4
V2
R1 R2
-10 v]
3
/re
m
1c V3
-20 re v [8
n/
3
4i
4.9
-30 B
-40 L2 FA FA1 GB
X 2 X1 P L1 L3 GT
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
30
v]
3
/re
6 cm
20 v [13 PS GS GA
3
/re
9 in X2
8.2
10 X1
V1
A
Angle (°)
V4
0
V2
R1 R2
-10 v]
3 re V3
/
6 cm
-20 v [13
3
/re Z1a
9 in
8.2
Z2a
B
-30
L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
-40
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
L (CCW) Rotation
m
m
40°
]
40°
NOTE:
The spring return feature in the control unit is not a
safety device. Internal contamination (contaminated
hydraulic fluid, abrasion or residual contamination from
system components) can cause the spool valve inside Correlation between direction of rotation (shaft view) control
and direction of flow.
the control unit to get stuck in an undefined position. As
a result, the axial piston unit will no longer supply the
specified flow. Check which remedial measures should
taken on your machine in order to bring the driver
consumer into a safe position (e.g. immediate stop).
C
C055 Pilot Pressure vs. Displacement D
20 [290] 20 [290]
16 [232] 3
/re
v] 16 [232]
cm ]
[55 rev
m/
3
12 [174] /re
v 12 [174] 5 5c
ev [
3
n
5i n /r
3
3.3 5i
3.3
8 [116] 8 [116]
Pressure Bar (psi)
0 0
-4 [-58] -4 [-58]
5i
3
/ rev 3.3
in
-16 [-232] 3.35 -16 [-232]
00
-20 [-290] Pilot pressure -20
= 6÷18 bar [87÷261 psi] (at ports Y1, Y2)
[-290]
Start of control = 6 bar [87 psi]
-100 -80 -60 -40 -20 0 20 40 60 80 100 -100
End of control = 18 bar [261 psi]-80
(Max -60 -40 -20
displacement) 0 20 40 60 80 100
Displacement (%) Displacement (%)
C081 Pilot Pressure vs. Displacement
20 [290]
16 [232] 3
/re
v]
c m Y2 Y1
[81
12 [174] 3
/re
v
GS GA
n PS T
4i
4.9 Z1
8 [116] V1
Pressure Bar [psi]
Z2 A
4 [58] V4
V2
0 R1 R2
-4 [-58] V3
-8 [-116]
v]
3
/re B
c m
-12 [-174] [81
rev
n/
3
4i L2 FA
-16 [-232] 4.9
X 2 X1 P L1 L3 GT FA1 GB
-20 [-290] Pilot pressure = 6÷18 bar [87÷261 psi] (at ports Y1, Y2)
-100 -80 -60 -40 -20 0 20 40 60 80 100 Start of control = 6 bar [87 psi]
End of control = 18 bar [261 psi] (Max displacement)
Displacement (%)
4 [58] V4
V2
R1 R2
0
V3
-4 [-58]
Z1a
-8 [-116]
v] Z2a
/re
3
B
cm
-12 [-174] 1 36
v[
3
n /re Z1 Z 2 S L1
L2
L3 GT FA2 FA1 GB
-16 [-232] 9i
8.2
-20 [-290]
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
3.3 3.3
5
8 [116] 8 [116]
Pressure Bar (psi)
Current (mA)
0 0
-4 [-58] -4 [-58]
4
4.9
8 [116]
Pressure Bar (psi)
PS GS GA
4 [58] Z1
V1 A
Z2
0
V4
-4 [-58] V2
R1 R2
-8 [-116] 3 rev
/
]
V3
cm
[81
-12 [-174] rev
in /
3
4
4.9
-16 [-232] B
-20 [-290]
X2 X1 P L1 L2 L3 GT FA FA1 GB
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%) Pilot pressure = 6÷14 bar [87÷203 psi] (at ports Y1, Y2)
Maximum pilot pressure = 30 bar [435 psi]
Nominal output shown. Actual output will vary depending on input speed
Start of control = 6 bar [87 psi]
and system pressures.
End of control = 14 bar [203 psi] (Max displacement)
9i PS GS GA
8.2
8 [116] X2
X1
Pressure Bar [psi]
A
4 [58]
V4
0 R1 R2
V2
-4 [-58] V3
-8 [-116]
v] Z1a
3
/re Z2a
m
6c
B
-12 [-174] [13
v
n
3
/re
-16 [-232] 9i L2 FA2
8.2
Z1 Z2 S L1 L3 GT FA1
-20 [-290]
Pilot pressure = 6÷14 bar [87÷203 psi] (at ports Y1, Y2)
-100 -80 -60 -40 -20 0 20 40 60 80 100 Maximum pilot pressure = 30 bar [435 psi]
Start of control = 6 bar [87 psi]
Displacement (%) End of control = 14 bar [203 psi] (Max displacement)
Nominal output shown. Actual output will vary depending on input speed
and system pressures.
NOTE:
The tolerance on piloting pressure is ± 10% of
maximum value. R (CW) Rotation
WARNING:
Use of the D control can require a review of the
motor engine and vehicle parameters to ensure that
the pump is set up correctly. We recommend that
applications be reviewed by a Parker technician. Correlation between direction of rotation (shaft view) control
and direction of flow.
Electric Non-Proportional – E
By turning on one of the on-off solenoids (standard
24V d.c. optional 12V d.c.), the pump swivels to
maximum displacement in the corresponding output
flow direction. Turning off the solenoid results in
swiveling the pump back to zero displacement position.
C055 C081
PS GS GA
Z1
V1
Z2 A
V4
V2
R1 R2
V3
L2 FA
X2 X1 P L1 L3 GT FA1 GB
C136
PS GS GA
X2
X1
V1
A
V4
V2
R1 R2
V3
Z1a
Z2a
B
L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
Direction of Rotation
L (CCW) Rotation
R (CW) Rotation
NOTE:
The tolerance on control coil amperage is ± 10% of
maximum value.
30 Watt coils
12 VDC coil resistance of 18.8 ohms
24 VDC coil resistance of 18.8 ohms
F G
C055 Amperage vs. Displacement
1200 1400
1000 v] 1200
/re v]
/re
3
cm
3
m
55 5c
800 v[ 1000 v[
5
/re re
n/
3
in
3
35 5i
600 3. rev
] 800 3.3
m/
3
c
12V [55 12V
400 in
3
/rev 600
.35 3
/rev
3 5 cm
24V rev [5
5 in /
3
Current (mA)
0 200
-200 24V 0
] 12V
rev -200
-400 m/
3
5 5c 24V
ev [
n /r
3
-600 5i -400
3.3 v] ev]
/re m /r
3
c
[55
3
cm /rev 12V
-800 -600
3
5 in
v [5 3.35
3 /re
-1000 in -800 v]
35 /re
3.
3
m
5 5c
-1200 -1000 re v[
n/
3
1000 v]
3 /re
cm
800 81
v[
3 /re PS GS GA
in
600 94 Z1
4. 3 rev
]
/
cm V1
[81
A
400 12V 3
/rev
Z2
in
4 .94 V4
24V
200
Current (mA)
V2
R1 R2
0 V3
12V
-200
rev
] 24V
-400 m/
3 B
8 1c
ev [
n /r
3
4i
-600 4.9 v] L2 FA
/re
X 2 X1 P L1 L3 GT FA1 GB
3
cm
-800 81
v[ Solenoid 24V: Current min. 200 mA max 600 mA
3 /re
in Solenoid 12V: Current min. 400 mA max 1200 mA
-1000 94
4. PWM frequency: 110 Hz
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
1000 v]
3 /re
cm
6
800 13
v[
3 /re PS GS GA
in
600 29 ]
8. 3
/rev
X2
m X1
12V 6c V1
[13 A
400 rev
in /
3
8.29 V4
24V
Current (mA)
200 V2
R1 R2
0
V3
-200 12V
Z1a
]
-400 m
3
/rev 24V Z2a
13 6c B
[
/ 3 rev
-600 9 in
8.2 v]
/re
L2 FA2
3 Z1 Z2 S L1 L3 GT FA1 GB
cm
-800 [1
36
v
3 /re Solenoid 24V: Current min. 200 mA max 600 mA
-1000 in
29 Solenoid 12V: Current min. 400 mA max 1200 mA
8.
PWM frequency: 110 Hz
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
Time in seconds
*Standard orifice
Fluid viscosity = 50 cSt
Input speed = 1500
250 bar (3600 PSI) working pressure
22 bar (320 PSI) charge pressure
NOTE:
The tolerance on control coil amperage is ± 10% of R (CW) Rotation
maximum value.
The spring return feature in the control unit is not a
safety device. Internal contamination (contaminated
hydraulic fluid, abrasion or residual contamination from
system components) can cause the spool valve inside
the control unit to get stuck in an undefined position. Correlation between direction of rotation (shaft view) control
and direction of flow.
As a result, the axial piston unit will no longer supply
the specified flow. Check which remedial measures
should taken on your machine in order to bring the driver
consumer into a safe position (e.g. immediate stop).
G
C055 Amperage vs. Displacement
1400
1200 v]
3 /re
m
5c
1000 [5
rev
n/
3
i
800 3 .35
600 12V
3
/rev]
5 cm
in
3
/rev [5
400 3.35
24V
Current (mA)
200
-200
24V
-400 ev ]
m /r
3
55 c
ev [ 12V
-600 in /r
3
3.35
-800 v]
3 /re
m
55c
-1000 v[
3
n /re
5i
-1200 3.3
-1400
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
1400
1200 v]
3 /re
m
[81c
1000
rev
n/
3
i
800 4 .94
PS GS GA
12V /rev
] Z1
600
3
cm
ev [81
in /r
3 V1
A
4.94
Z2
400
24V
Current (mA)
V4
200 V2
R1 R2
0
V3
-200
12V
-400
ev]
B
m /r
3
81 c 24V
-600 ev [
in /r
3
4.94 X2 X1 P L1
L2
L3 GT
FA FA1 GB
-800 3 /re
v]
cm
-1000 81
re v[ Solenoid 24V: Current min. 300 mA max 650 mA
n/
3
-1400
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
1400
1200 v]
3 /re
m
6c
1000 [13
3 / rev
800 9 in
8.2 PS GS GA
ev ]
600 12V c m /r
3 X2
X1
v[ 136 V1
A
n /re
3
400 8.29 i V4
24V
V2
Current (mA)
200 R1 R2
V3
0
Z1a
-200
12V Z2a
B
-400 ev]
m /r
3
L2
36 c Z1 Z2 S L1 L3 GT FA2 FA1 GB
1 24V
-600 ev [
in /r
3
Displacement (%)
Nominal output shown. Actual output will vary depending on
input speed and system pressures.
L (CCW) Rotation
NOTE:
The tolerance on control coil amperage is ± 10% of
maximum value.
WARNING:
Use of the G control can require a review of the
engine and vehicle parameters to ensure that the
pump is set up correctly. We recommend that
applications be reviewed by a Parker technician.
R (CW) Rotation
1200
1000 v]
3 /re
cm
55
800 v[
3 /re
in
35
600 3. ]
rev
m/
3
5 5c
12V ev [
400 n /r
3
5i
3.3
24V
200
Current (mA)
0
12V
-200
] 24V
3
/rev
-400 55
cm
ev [
n /r
3
5i
-600 3.3 v]
3 /re
cm
-800 55
v[
3 /re
in
-1000 35
3.
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
1200
1000 v]
3 /re
cm S1
1
800 v [8 Y2 Y1
3 /re
in
600 94
4. ]
/rev
PS GS GA
3
cm Z1
12V 81
ev [
400 n /r
3
4i V1
4.9 Z2 A
24V
200
Current (mA)
V4
V2
0 R1 R2
12V V3
-200
rev
] 24V
-400 m/
3
8 1c
ev [ B
n /r
3
4i
-600 4.9 v]
3 /re
cm
L2 FA
X2 X1 P L1 L3 GT FA1 GB
-800 8 1
v[
3 /re
in
-1000 94
4.
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
1200
1000 v]
3 /re S1
cm
800 1 36 Y2 Y1
v[
3 /re
in
600 29 ] PS GS GA
8. rev
m/
3
c X2
12V [136 X1
400 3
/rev V1
A
9 in
8.2
24V V4
Current (mA)
200
V2
R1 R2
0
V3
-200 12V
Z1a
]
-400
3
/rev 24V Z2a
6 cm B
3 rev
[13
/
-600 9 in
8.2 v] L2
/re Z1 Z2 S L1 L3 GT FA2 FA1 GB
3
cm
-800 1 36
v[
3 /re
-1000 in
29
8.
-1200
-100 -80 -60 -40 -20 0 20 40 60 80 100
Displacement (%)
Time in seconds
*Standard orifice
Fluid viscosity = 50 cSt
Input speed = 1500
250 bar (3600 PSI) working pressure
22 bar (320 PSI) charge pressure
NOTE:
R (CW) Rotation
The tolerance on control coil amperage is ± 10% of
maximum value.
The spring return feature in the control unit is not a
safety device. Internal contamination (contaminated
hydraulic fluid, abrasion or residual contamination from
system components) can cause the spool valve inside
Correlation between direction of rotation (shaft view) control
the control unit to get stuck in an undefined position. and direction of flow.
As a result, the axial piston unit will no longer supply
the specified flow. Check which remedial measures
should taken on your machine in order to bring the driver
consumer into a safe position (e.g. immediate stop).
WARNING:
Y1 and Y2 ports must not have any back pressure
during normal electric control operation (vented
to tank).
Automotive – J/K Units with this control also have the option for having
a flushing valve mounted onto the pump.
The automotive control is primarily used in propel
applications where a transmission needs to act similar to This control is naturally speed and torque sensitive
automotive vehicles with automatic transmissions where so your Parker representative will need to know more
an operator selects direction of travel and then controls information on the prime mover driving the pump to
the prime mover rpm to control vehicle travel speed. ensure it is properly applied.
C055 Electric (J) / Hydraulic (K) Automotive With C081 Electric (J) / Hydraulic (K) Automotive With
Hydraulic Inching + Flushing Valve Hydraulic Inching + Flushing Valve
Y1 K Y2
J
St Pi UNF
Pi Gas
VC VS In
T1
VT
T GS GA
PS
Z1
V1 A
Z2
V4
R2 V2
R1
V3
L2 FA
X2 X1 P L1 L3 GT FA1 GB
X2 X1 S L1 L2 L3 GT FA2 FA1 GB
Y2 Y2
Y1 Y1
B B
A
A
S2 S2
S1 S1
A A
Correlation between direction of rotation (shaft view) control and direction of flow.
Pressure Override – P
The pressure override valve is designed to avoid close to the relief valve’s setting, or in hydraulic systems
opening relief valves. When working pressure reaches engineered to maximum pump pressure. The pressure
the P valve setting, the swash plate swivels back and override should be set 20 – 30 bar (290 – 435 psi) lower
reduces flow. The valve maintains a constant pressure than the cross port relief valve setting. Setting range:
in the circuit at the setting value. It is advisable to fit 100 – 420 bar (1,450 – 6,090 psi)
the cut-off valve to all systems where pressure peaks
C055 With Type P Pressure Override C136 With Type P Pressure Override
PS GS GA
X2
X1 V1
A
V4
V2
R1 R2
V3
Z1a
Z2a
B
L2 FA2
Z1 Z2 S L1 L3 GT FA1 GB
Note:
The electric override valve can be assembled on standard
C pumps and combined with pressure override valves.
S2
PS GS GA
Z1
V1 A
Z2
V4
V2
R1 R2
V3
L2 FA
X2 X1 P L1 L3 GT FA1 GB
S2
S1
PS GS GA
Z1
PS GS GA
V1 A
Z2 X2
V4 X1 V1
A
V2
R1 R2 V4
V3 V2
R1 R2
V3
B
Z1a
L2 FA FA1 GB Z2a
X 2 X1 P L1 L3 GT
B
L2 FA2 FA1 GB
Z1 Z2 S L1 L3 GT
To guarantee an optimum fluid contamination level in filtering element. Electrical (connector DIN 43650) and
the closed loop, the C pump can be equipped with mechanical filter clogging sensors (standard 8 bar/116
a filter. It is positioned on the delivery outlet of the psi) are available. It’s possible to combine the filter with
charge pump. The filter contains a composite-fiber cut-off valves.
1 N.A. 3
2 N.C.
S1
S1
PS GS GA
PS GS GA
Z1 Z1
V1 A V1
Z2 Z2 A
V4 V4
V2 V2
R1 R2 R1 R2
V3 V3
B B
L2 FA
X2 X1 L2 FA X 2 X1 P L1 L3 GT FA1 GB
P L1 L3 GT FA1 GB
1 N.A. 3
2 N.C.
S1
S1
PS GS GA
PS GS GA
X2
X1 X2
V1
A X1
V1
A
V4
V4
V2
R1 R2 V2
R1 R2
V3
V3
Z1a
Z1a
Z2a Z2a
B B
L2 FA2 L2
Z1 Z2 S L1 L3 GT FA1 GB Z1 Z2 S L1 L3 GT FA2 FA1 GB
V4
Z2a
Valve block supplied on the pumps with ports for Z1 Z2 S L1 L2 L3 GT FA2 FA1 GB
C055 With Remote Charge Filtration C136 With Remote Charge Filtration
IN
OUT
X2 PS GS GA
X1 V1
A
V4
V5 V2
R1 R2
V3
B
Z1a
Z2a
Z1 Z2 S L1 L2 L3 GT FA2 FA1 GB
IN
OUT
X2 PS GS GA
X1 V1
A
V4
V2
R1 R2
V3
B
Z1a
Z2a
Z1 Z2 S L1 L2 L3 GT FA2 FA1 GB
IN
OUT
X2 PS GS GA
X1 V1
A
V4
V5 V2
R1 R2
V3
Parker Hannifin Corporation B
Hydraulic
Z1a Pump and Power Systems Division
United States
35
Z2a
Z1 Z2 S L1 L2 L3 GT FA2 FA1 GB
HY28-2686-01/C/US Variable Displacement Axial Piston Pumps
Charge Filtration Options C Series
[69 mm]
counterclockwise. The bypass valve is intended for
2.72 in
use at low vehicle speeds. Moving at high speeds
may cause damage to transmission components and
cause an excess of heat generation.
C055
[66.5 mm]
2.62 in
C081
PS T GS GA
Z1
V1
Z2 BYPASS
A
V4
V2
R1 R2
V3
L2 FA
X2 X1 P L1 L3 GT FA1 GB
A Control
8.80 in [223.5 mm]
0.16 in [4 mm]
1.09 in [27.8 mm]
3.66 in [93 mm]
4.17 in [105.9 mm] 4.89 in [119.2 mm] o1.02 in [o26 mm]
0.50 in [12.7 mm]
0.56 in [14.3 mm] nº4
[76 mm]
2.99 in
[20 mm]
0.79 in
L1 Z1
in
[o
8
m
m
S
]
PS
[92 mm]
3.62 in
[59 mm]
2.32 in
GA X2 Z2
8.66 in [220 mm] 1.87 in [47.5 mm]
GS FA 0.43 in [11 mm] GB
9.51 in [241.5 mm]
2.18 in [55.4 mm]
11.20 in [284.5 mm]
8.35 in [212 mm]
C Control
Y1 Y2
Y1-Y2: Control piloting pressure ports – 1/4"G (BSPP) (ISO) 4.93 in [125.3 mm]
7/16" – 20 UNF 2B (SAE)
D Control
6.43 in [163.2 mm]
2.89 in [73.5 mm]
Y1 Y2
E Control
Connector DIN 43650 (ISO4400)
F Control
G Control
Connector DIN 43650 (ISO4400)
[148 mm]
[123.8 mm]
5.83 in
4.87 in
H Control
Shaft
1: Splined SAE 1 - 1/4" 14T 12/24 Dp – Flat Root Class 5 ANSI B92.1a – 1976
[o31.2 mm]
[o34 mm]
o1.338 in
o1.228 in
2: Splined SAE 1 - 3/8" 21T 16/32 Dp – Flat Root Class 5 ANSI B92.1a – 1976
[o34 mm]
o1.338 in
o1.228 in
Size 055
2 1
Drive shaft
Z21 16/32 DP Z14 12/24 DP
Drive shaft max torque Nm [lbf·ft] 950 (700) 620 (457)
Through drive max torque Nm [lbf·ft] 665 (490) 620 (457)
Splined
SAE A 5/8 9T 16/32 DP
OR 2.62x82.22 (2-152)
OR 2.62x101.27 (2-155)
Splined
SAE C 1-1/4 14T 12/24DP
OR 3.53x126.6 (2-250)
(ISO) Holes M16x2; 30 (1.18) Deep
(SAE) Holes 5/8 11UNC-2B; 30 (1.18) Deep
A Control
8.4 in [212.6 mm]
Ø5 in [Ø127 mm]
B GT
2.74 in [69.6 mm]
A
1.18 in [30 mm]
GS
FA2 GB 8.77 in [222.7 mm]
C Control
2.07 in [52.5 mm] 2.07 in [52.5 mm] 5.61 in [142.6 mm]
V1
V1
Y2 Y1
V1
5.42 in [137.6 mm]
4.89 in [124.1 mm]
Y2 Y1
E Control
6.22 in [158 mm]
4.69 in [119.2 mm]
Connector DIN43650 (ISO4400)
V1
F Control
Connector Deutsch DT04-2P
V1
5.99 in [152.1 mm]
5.99 in [152.1 mm]
G Control
5.41 in [137.3 mm]
6.73 in [171 mm]
Connector DIN43650 (ISO4400)
4.76 in [121 mm] 4.7 in [119.3 mm]
H Control
4.69 in [119 mm] 4.69 in [119 mm]
Connector Deutsch DT04-2P
S1
V1
6.68 in [169.7 mm]
Y2 Y1
In
Pi UNF T
Pi Gas
0.77 in [19.5 mm]
0.51 in [13 mm]
T1
6.36 in [161.6 mm]
In
Pi UNF T T
Pi Gas
0.77 in [19.5 mm]
0.51 in [13 mm]
T1
4.07 in [103.5 mm] 6.36 in [161.6 mm]
Shaft
1: Splined SAE 1 - 1/4" 14T 12/24 Dp – Flat Root Class 5 ANSI B92.1a – 1976
3/8-16UNC-2B
39.3 in [1.55 mm]
2: Splined SAE 1 - 3/8" 21T 16/32 Dp – Flat Root Class 5 ANSI B92.1a – 1976
Filter
6.3 in [160 mm]
Override Option E
6.04 in [153.5 mm]
Override Option P
5.47 in [139 mm]
7.6 in [193.1 mm] Cut-Off Pressure Setting (M10) 4.74 in [120.5 mm]
Connector DIN43650
(ISO4400)
By-Pass (01)
Size 081
2 1
Drive shaft
Z21 16/32 DP Z14 12/24 DP
Drive shaft max torque Nm [lbf·ft] 950 (700) 620 (457)
Through drive max torque Nm [lbf·ft] 665 (490) 620 (457)
Splined
SAE A 5/8 9T 16/32 DP
No. 2 M12
1/2-13 UNC-2B OR 2.62 x 101.27 (2-155)
0.39 in [10 mm]
0.79 in [20 mm]
Splined
SAE C 1-1/4 14T 12/24 DP
SAE C-C 1-1/2 17T 12/24 DP
4.51 in [114.6 mm]
5 in [Ø127mm]
A Control
V1 L1
Z2a
Ø6 in [Ø152.4 mm]
8.07 in [204.9 mm]
L3
FA2 A FA2
GT 7.283 in [185 mm] 0.50 in [12.7 mm]
1.043 in [26.5 mm] 2.165 in [55 mm] GA
10.267 in [260.8 mm]
6.362 in [161.6 mm]
14.34 in [364.3 mm]
9.016 in [229 mm]
10.47 in [266 mm]
GS X1
3m
Z1
3.149 in [80 mm]
0.9
S
pt
De
C Control
V1
D Control
5.429 in [137.9 mm] 1.44 in [36.7 mm]
1.45 in [36.8 mm]
V1
6.63 in [168.5 mm]
E Control
Connector DIN43650 (ISO4400)
V1
8.33 in [211.5 mm]
V1
V1
6.79 in [172.5 mm]
H Control
Connector Deutsch DT04-2P
V1
7.09 in [180 mm]
Y1
Y2
In
Hydraulic inching valve
T
0.51 in [13 mm]
0.04 in [1 mm]
Shaft
3: Splined 13T 8/16 Dp ANSI B92.1a 4: Splined 15T 8/16 Dp ANSI B92.1a
1976 Flat Root 1976 Flat Root
5/8 – 11UNC – 2B
5/8 – 11UNC – 2B
2.35 in [59.6 mm]
2.70 in [68.6 mm]
5: Splined 23T 16/32 Dp ANSI B92.1a 6: Splined 27T 16/32 Dp ANSI B92.1a
1976 Flat Root 1976 Flat Root
M10
M10
M16
Size 136
3 4 5 6 7 8
Drive shaft
Z13 8/16 DP Z15 8/16 DP Z23 16/32 DP Z27 16/32 DP W40x2x30x18 W45x2x30x21
Drive shaft max torque Nm [lbf·ft] 1640 (1208) 2670 (1967) 1250 (921) 1900 (1400) 1460 (1076) 2190 (1614)
Through drive max torque Nm [lbf·ft] 1000 (737) 1000 (737) 1000 (737) 1000 (737) 1000 (737) 1000 (737)
Prof./Depth 13 [0.51]
1.772 in [45 mm]
7/16-20 UNF-2B
M10 Depth [0.71]
Prof./Depth 12 [0.47]
1/4 G (BSPP)
4 in [Ø101.6 mm]
SAE B 7/8 13T 16/32 DP
SAE B-B 1" 15T 16/32 DP
No. 2 M12
1/2-13 UNC-2B OR 2.62 x 101.27 (2-155)
0.393 in [10 mm]
0.79 in [20 mm]
Splined
SAE C 1" 1/4 14T 12/24 DP
SAE C-C 1" 1/2 17T 12/24 DP
5 in [Ø127 mm]
6 in [Ø152.4 mm]
OR 3.53 x 151.99 (2-258)
2.88 in 73.1 mm]
9 in [228.6 mm]
No. 4 holes M20 No. 2 holes M20
3/4-10 UNC-2B 10.63 in [270 mm]
Long line lengths and sharp turns in the fluid conveyance Air bleed port should only be used while filling the case
will add additional pressure loss or restriction to the of the unit to ensure the unit is completely filled with
system. It is recommended to keep the line lengths as fluid. Once unit is filled, the air bleed port should be
short as possible and to avoid as many fluid direction closed via a port plug or shut off valve.
changes in the system as possible.
Fluid
Table 1 Parker recommends using a fluid with a petroleum base
and contains agents which provide oxidation inhibition
Function Fluid Velocity m/sec (Ft/sec) and anti-rust, anti-foam and deteriorating properties as
Suction 0.6-1.2 (2-4) described in Parker standard HF-1. Where anti-wear
Case drain 1.5-3 (5-10) additive fluids are specified, see Parker standard HF-0.
Pressure 3-6 (10-20)
Use fluids with a minimum Viscosity index of 90.
Higher viscosity index extend the range of operating
temperatures but may reduce the service life of the fluid.
A B* C
D E
A Air bleed
OIL B OIL C OIL
Air bleed
L3
L2
L3
L1
D OIL
E OIL
L2
L1/L2
The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (“Seller”)
are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and
Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods,
services or work described will be referred to as “Products”.
1. Terms and Conditions. Seller’s willingness to offer Products, or accept an attorney fees), whether for personal injury, property damage, patent, trademark or
order for Products, to or from Buyer is subject to these Terms and Conditions or copyright infringement or any other claim, brought by or incurred by Buyer,
any newer version of the terms and conditions found on-line at Buyer’s employees, or any other person, arising out of: (a) improper selection,
www.parker.com/saleterms/. Seller objects to any contrary or additional terms or improper application or other misuse of Products purchased by Buyer from Seller;
conditions of Buyer’s order or any other document issued by Buyer. (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use of
2. Price Adjustments; Payments. Prices stated on Seller’s quote or other patterns, plans, drawings, or specifications furnished by Buyer to manufacture
documentation offered by Seller are valid for 30 days, and do not include any Product; or (d) Buyer’s failure to comply with these terms and conditions. Seller
sales, use, or other taxes unless specifically stated. Unless otherwise specified by shall not indemnify Buyer under any circumstance except as otherwise provided.
Seller, all prices are F.C.A. Seller's facility (INCOTERMS 2010). Payment is 12. Cancellations and Changes. Orders shall not be subject to cancellation or
subject to credit approval and is due 30 days from the date of invoice or such change by Buyer for any reason, except with Seller's written consent and upon
other term as required by Seller’s Credit Department, after which Buyer shall pay terms that will indemnify, defend and hold Seller harmless against all direct,
interest on any unpaid invoices at the rate of 1.5% per month or the maximum incidental and consequential loss or damage. Seller may change product features,
allowable rate under applicable law. specifications, designs and availability with notice to Buyer.
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate 13. Limitation on Assignment. Buyer may not assign its rights or obligations
and Seller shall not be responsible for any damages resulting from any delay. under this agreement without the prior written consent of Seller.
Regardless of the manner of shipment, title to any products and risk of loss or 14. Force Majeure. Seller does not assume the risk and shall not be liable for
damage shall pass to Buyer upon placement of the products with the shipment delay or failure to perform any of Seller’s obligations by reason of circumstances
carrier at Seller's facility. Unless otherwise stated, Seller may exercise its beyond the reasonable control of Seller (hereinafter “Events of Force Majeure”).
judgment in choosing the carrier and means of delivery. No deferment of shipment Events of Force Majeure shall include without limitation: accidents, strikes or labor
at Buyers' request beyond the respective dates indicated will be made except on disputes, acts of any government or government agency, acts of nature, delays or
terms that will indemnify, defend and hold Seller harmless against all loss and failures in delivery from carriers or suppliers, shortages of materials, or any other
additional expense. Buyer shall be responsible for any additional shipping cause beyond Seller’s reasonable control.
charges incurred by Seller due to Buyer’s acts or omissions. 15. Waiver and Severability. Failure to enforce any provision of this agreement
4. Warranty. Seller warrants that the Products sold hereunder shall be free from will not waive that provision nor will any such failure prejudice Seller’s right to
defects in material or workmanship for a period of eighteen months from the date enforce that provision in the future. Invalidation of any provision of this agreement
of shipment from the Company. The prices charged for Seller's products are by legislation or other rule of law shall not invalidate any other provision herein.
based upon the exclusive limited warranty stated above, and upon the following The remaining provisions of this agreement will remain in full force and effect.
disclaimer: DISCLAIMER OF WARRANTY: THIS WARRANTY COMPRISES 16. Termination. Seller may terminate this agreement for any reason and at any
THE SOLE AND ENTIRE WARRANTY PERTAINING TO PRODUCTS time by giving Buyer thirty (30) days written notice of termination. Seller may
PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRANTIES, immediately terminate this agreement, in writing, if Buyer: (a) commits a breach of
EXPRESS AND IMPLIED, INCLUDING DESIGN, MERCHANTABILITY AND any provision of this agreement (b) appointments a trustee, receiver or custodian
FITNESS FOR A PARTICULAR PURPOSE. for all or any part of Buyer’s property (c) files a petition for relief in bankruptcy on
5. Claims; Commencement of Actions. Buyer shall promptly inspect all its own behalf, or by a third party (d) makes an assignment for the benefit of
Products upon delivery. No claims for shortages will be allowed unless reported to creditors, or (e) dissolves or liquidates all or a majority of its assets.
the Seller within 10 days of delivery. No other claims against Seller will be allowed 17. Governing Law. This agreement and the sale and delivery of all Products
unless asserted in writing within 30 days after delivery. Buyer shall notify Seller of hereunder shall be deemed to have taken place in and shall be governed and
any alleged breach of warranty within 30 days after the date the defect is or construed in accordance with the laws of the State of Ohio, as applicable to
should have been discovered by Buyer. Any action based upon breach of this contracts executed and wholly performed therein and without regard to conflicts of
agreement or upon any other claim arising out of this sale (other than an action by laws principles. Buyer irrevocably agrees and consents to the exclusive
Seller for an amount due on an y invoice) must be commenced within 12 months jurisdiction and venue of the courts of Cuyahoga County, Ohio with respect to any
from the date of the breach without regard to the date breach is discovered. dispute, controversy or claim arising out of or relating to this agreement.
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS 18. Indemnity for Infringement of Intellectual Property Rights. Seller shall
OPTION, REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE have no liability for infringement of any patents, trademarks, copyrights, trade
PURCHASE PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER dress, trade secrets or similar rights except as provided in this Section. Seller will
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL defend and indemnify Buyer against allegations of infringement of U.S. patents,
DAMAGES ARISING OUT OF, OR AS THE RESULT OF, THE SALE, U.S. trademarks, copyrights, trade dress and trade secrets (“Intellectual Property
DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE Rights”). Seller will defend at its expense and will pay the cost of any settlement or
PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR damages awarded in an action brought against Buyer based on an allegation that
EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER'S WRITTEN a Product sold pursuant to this Agreement infringes the Intellectual Property
CONSENT, EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN Rights of a third party. Seller's obligation to defend and indemnify Buyer is
CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL contingent on Buyer notifying Seller within ten (10) days after Buyer becomes
SELLER'S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE aware of such allegations of infringement, and Seller having sole control over the
PURCHASE PRICE OF THE PRODUCTS. defense of any allegations or actions including all negotiations for settlement or
7. User Responsibility. The user, through its own analysis and testing, is solely compromise. If a Product is subject to a claim that it infringes the Intellectual
responsible for making the final selection of the system and Product and assuring Property Rights of a third party, Seller may, at its sole expense and option,
that all performance, endurance, maintenance, safety and warning requirements procure for Buyer the right to continue using the Product, replace or modify the
of the application are met. The user must analyze all aspects of the application Product so as to make it noninfringing, or offer to accept return of the Product and
and follow applicable industry standards and Product information. If Seller return the purchase price less a reasonable allowance for depreciation.
provides Product or system options, the user is responsible for determining that Notwithstanding the foregoing, Seller shall have no liability for claims of
such data and specifications are suitable and sufficient for all applications and infringement based on information provided by Buyer, or directed to Products
reasonably foreseeable uses of the Products or systems. delivered hereunder for which the designs are specified in whole or part by Buyer,
8. Loss to Buyer's Property. Any designs, tools, patterns, materials, drawings, or infringements resulting from the modification, combination or use in a system of
confidential information or equipment furnished by Buyer or any other items any Product sold hereunder. The foregoing provisions of this Section shall
which become Buyer's property, will be considered obsolete and may be constitute Seller's sole and exclusive liability and Buyer's sole and exclusive
destroyed by Seller after two consecutive years have elapsed without Buyer remedy for infringement of Intellectual Property Rights.
ordering the items manufactured using such property. Seller shall not be 19. Entire Agreement. This agreement contains the entire agreement between
responsible for any loss or damage to such property while it is in Seller's the Buyer and Seller and constitutes the final, complete and exclusive expression
possession or control. of the terms of sale. All prior or contemporaneous written or oral agreements or
9. Special Tooling. A tooling charge may be imposed for any special tooling, negotiations with respect to the subject matter are herein merged.
including without limitation, dies, fixtures, molds and patterns, acquired to 20. Compliance with Law, U. K. Bribery Act and U.S. Foreign Corrupt
manufacture Products. Such special tooling shall be and remain Seller's property Practices Act. Buyer agrees to comply with all applicable laws and regulations,
notwithstanding payment of any charges by Buyer. In no event will Buyer acquire including both those of the United Kingdom and the United States of America, and
any interest in apparatus belonging to Seller which is utilized in the manufacture of of the country or countries of the Territory in which Buyer may operate, including
the Products, even if such apparatus has been specially converted or adapted for without limitation the U. K. Bribery Act, the U.S. Foreign Corrupt Practices Act
such manufacture and notwithstanding any charges paid by Buyer. Unless (“FCPA”) and the U.S. Anti-Kickback Act (the “Anti-Kickback Act”), and agrees to
otherwise agreed, Seller shall have the right to alter, discard or otherwise dispose indemnify and hold harmless Seller from the consequences of any violation of
of any special tooling or other property in its sole discretion at any time. such provisions by Buyer, its employees or agents. Buyer acknowledges that they
10. Buyer's Obligation; Rights of Seller. To secure payment of all sums due or are familiar with the provisions of the U. K. Bribery Act, the FCPA and the Anti-
otherwise, Seller shall retain a security interest in the goods delivered and this Kickback Act, and certifies that Buyer will adhere to the requirements thereof. In
agreement shall be deemed a Security Agreement under the Uniform Commercial particular, Buyer represents and agrees that Buyer shall not make any payment or
Code. Buyer authorizes Seller as its attorney to execute and file on Buyer's behalf give anything of value, directly or indirectly to any governmental official, any
all documents Seller deems necessary to perfect its security interest. foreign political party or official thereof, any candidate for foreign political office, or
11. Improper use and Indemnity. Buyer shall indemnify, defend, and hold any commercial entity or person, for the purpose of influencing such person to
Seller harmless from any claim, liability, damages, lawsuits, and costs (including purchase products or otherwise benefit the business of Seller. 04/2014