Data Centre
Data Centre
Data Centre
Mega Business
Redundant Components: 2(N+N) Tier 4
Availability 99.995% Fault
Annual Down time: 0.4hrs Tolerant
Medium Business
Tier 2 No. of Delivery Paths: 1
Redundant Components: N+1 Availability
Redundant Components (T1 + Redundant Capacity
99.749%
Component )
Annual Down time: 22.0hrs
Small Business
Redundant Components: N Tier 1 No. of Delivery Paths:
Availability 99.671% Basic 1
Annual Down time: 28.8hrs
Cooling: Racks:
PAC Server Rack
Containment Solution Network Rack
INRow Cooling Integrated Cooling Rack
RDHx Solution IPDU with Temp/Hum
Chip Level Cooling
Solutions
MODULAR & SCALABLE
Taylor Made Solutions
UPS: Offered
Standalone
Modular DCIM:
Rack Level Monitoring
Batteries: Room Level Monitoring
SMF Periodic Health Check
Lithium ion Real Time Alert
Data Centre Infrastructure :
13% 4%1%
13%
13%
9% Savings on
Space / Power /
Cooling
17% 17%
9% 4%
Changing Trends : Space, Power & Cooling
Changing trends in IT hardware in terms of servers, storages & switches is always a challenge for the
organization. An healthy organization or a growing organization is one, which has a balanced growth on both IT
& Facility.
55kW
3kW
IT Rack Density/Rack
IT HAS CHANGED
SINCE 1980’S TO 2020
6 Control Must, Hot/Cold Aisle Must, Hot Aisle Containment Each door has inbuilt water flow
Containment and Due Point control
7 False Floor Must Depends on situation Depends on situation
8 PUE (Power Usage 2 to 2.5 1.4 to 2.0 1.2 to 1.6
Effectiveness)
9 Carbon Footprint High Medium Lowest
10 ROI 16 to 28 months 12 to 20 months 6 to 10 months
Design Capacity: PAC Systems
Advantage: Dis-Advantage:
• Supports Upto 8kVA Per Rack. • PAC Design supports upto 197 Racks only
• Cold Aisle Containment avoids Hot & Cold Air Mixing, • Racks in the middle of the row, face very low air-flow.
resulting better efficiency. • Bottleneck found on the False floor, which has very low
• Active tiles can be used for higher KVA design. CFM output and Rack Door Perforation (80%) (Air Flow).
• Proven technology for more than 3 decades. • Support on HPC Servers, Blade Chassis and next
• Maintenance and work flow is very simple . generation servers are highly challenging.
• Suitable for small and medium server room. • Active tiles booster disturbs the air flow on other racks.
• Very Low efficiency.
• Higher PUE – 2.2 to 2.3.
• Consumes very high white space, results in lesser racks.
• Chilled Water supply @ 7oC/12oC which consumes higher
energy.
Cooling Comparison: INRow Systems
Advantage: Dis-Advantage:
• Supports Upto 20kVAPer Rack. • Scalability: Defined capacity, rackload cannot be increased
• 266 Racks compared to 197 Racks of PACdesign. in future when the demand increases.
• Lesserwhitespace compared to PACsolution. • Comfort: Person working in the Hot Aisle will be highly
• Efficiency of the equipment increases, since coolingis uncomfortable, as the temperature may go as high as 50oC.
provided very next to the cabinet. • Whitespace: Occupies Rack space, results in lesser racks.
• Hot Aisle Containment avoids, Hot & Cold Air Mixing, • Fansconsume high power and noice.
resulting better efficiency. • Average PUE– 1.9 to 2.0
• Modular Hot SwappableActive Fanshelps in achieving • Maintenance and work flow needs proper care.
higher heat load rejection. • Addition, Movement or change in cooling unit is very
Tota Total IT
Row 15kW 6kW l Load
Rac
k
(70%) (30%)
A 32 14 46 564
B 32 14 46 564
C 32 14 46 564
D 24 11 35 426
E 28 12 40 492
F 28 12 40 492
G 28 12 40 492
temperature decrease but without impacting the design. • Door Can be mounted to any existing rack (subject to rack load
• Lowestwhitespace compared to INROW & PACsolution. • In caseof server activity, maintenance or shutdown of 1 or few
• Efficiency of the equipment increases, since removal of heat is on the racks, the heat load of these racksare absorbed by the racksnext
cabinet. to the cabinet and maintains the Roomlevel temperature.
• Proven technology for more than 2 decades. • Datacenter isdivided into 2 Zones for easymaintenance and
• Chilled Water supply @ 14oC/20oC which consumes less energy. energy savings.
• LowestPUE– 1.5 to1.6 • RDHxhasinbuilt intelligence to control the water flow and
• Lower Capex– Increased Density, No Containment, Reduced Chiller maintain temperature above due point to avoid condensation.
capacity, RealEstate Cost and lowest OPEX. • Additional precaution is taken by providing PAHUunits with
• Lower TCO& ROI: Significantly faster than other energy efficient Humidifier and De-Humidifier.
cooling solutions.
Dis-Advantage:
• Supports TIERIII Design
• RDHx Door has singlepath.
Scalability: IT & CoolingLoad
Advantage: Advantage:
• Easy Access: Clients can easily mount or manage their
• Each Row will have dedicated Power distribution path,
equipment's at ease on both the rows.
water line Piping, etc…
• Dual Path: Each row will have dual distribution path of Chilled
water piping and electrical busduct. Dis-Advantage:
• Maintenance: Incase of maintenance work on Power or cooling, • In-case of server activity at the rear side of the cabinet,
this design is easy to manage. Hot air from the cabinet can affect the rack which is
• Cooling: In-case of server activity at the rear side of the cabinet, exactly below this rack.
Hot air (Heat Load) from the cabinet is evenly distributed and • Accessing the second row is very difficult, he may have to
shared among the cabinets around the rack. travel a lot.
Redundancy, Distribution and Concurrent Maintenance:
• Electrical: Transformer, Diesel Generator, Electrical Panels, UPS, Batteries, Floor PDU, Busduct
• Cooling: Chiller, Pumps, AHU, Make-up-tank, Water Line distribution (Dual Path).
• IPDU: Each is provided with dual Power Distribution Unit with Temperature & Humidity Sensor
Height 42U
Width 600mm
Depth 1200mm
Fully adjustable 19-inch rails
80% Perforated Steel Doors
1500kgs Load Capacity
Split hinged side panels
NEMA/IP20 Rating
Confirms to DIN 41494 and
EIA 310 and ROHs and
REACH Standards
IPDU – 3Phase (32A, 22kW)
IPDU Supports…
• Temperature/Humidity Sensor
• Smoke Sensor
• Water Leak Sensor
• Air Flow Sensor
• Beacon Sensor
• Door Contact etc…
• Works at 60°C Temperature
Over Head Networking
• Neat, Clean & easily accessible
• Troubleshooting made very simple
• Addressable & Aesthetic
RDHx – High Density Cooling Solution Upto 106kw/Rack