Shutdown SIS

Previous Screen

Product: TRACK-TYPE TRACTOR


Model: D3C III TRACK-TYPE TRACTOR 4KS
Configuration: D3C & D3C LGP, XL Series III Hystat Tractors 4KS00001-UP (MACHINE) POWERED BY 3046 Engine

Specifications
D3C, D4C AND D5C SERIES III HYSTAT TRACK-TYPE TRACTOR POWER
Media Number -SENR1249-00 Publication Date -06/05/1997 Date Updated -16/07/2008

SENR12490002

Hydrostatic Pump
113-9420, D3C (4KS1-UP, 4TS1-UP, 5GS1-UP); 114-3335 (With
Power Take Off), D3C (4KS1-UP, 4TS1-UP, 5GS1-UP); 113-
9423, D4C (6BS1-UP, 4LS1-UP, 8CS1-UP); D5C (5HS1-UP,
6CS1-UP, 7PS1-UP); 114-3336 (With Power Take Off), D4C
(6BS1-UP, 4LS1-UP, 8CS1-UP); D5C (5HS1-UP, 6CS1-UP,
7PS1-UP)
SMCS - 3107-010; 3107-017
(1)(5) D3C Front and Rear Pump Specifications

Type of pump ... Piston

Maximum displacement ... 71 cc/rev (4.33 cu in/rev)

Output ... 166 L/min (43.2 gal/min)

At a pressure of ... 6900 kPa (1000 psi)

With pump at ... 2400 rpm

Rotation is clockwise when viewed from drive end.

(2) Pressure Override Relief Valve:

Pressure setting ... 44000 ± 500 kPa (6381.76 ± 72.52 psi)

Installation torque ... 35 ± 3 N·m (25 ± 2 lb ft)

(3) Crossover Relief Valve (Forward) ... 47500 ± 750 kPa (6889.40 ± 108.78 psi)

Installation torque ... 100 ± 10 N·m (75 ± 5 lb ft)

(3) Crossover Relief Valve (Reverse) ... 47500 ± 750 kPa (6889.40 ± 108.78 psi)
Installation torque ... 100 ± 10 N·m (75 ± 5 lb ft)

(4) Charge pump ... 19 cc/rev (1.16 cu in/rev)

(6) Charge Relief Valve ... 2900 ± 100 kPa (420 ± 14 psi)

Installation Torque ... 70 ± 5 N·m (50 ± 5 lb ft)

(7) Torque for two bolts ... 240 ± 40 N·m (180 ± 30 lb ft)

(8) Inch lever actuation is counter clockwise (location off) (dimension A) ... 35 degree

For test, use SAE 10W oil at 65 °C (150°F).

(1)(5) D4C, D5C Front and Rear Pump Specifications

Type of pump ... Piston

Maximum displacement ... 90 cc/rev (5.49 cu in/rev)

Output ... 211.2 L/min (54.9 gal/min)

At a pressure of ... 6900 kPa (1000 psi)

With pump at ... 2400 rpm

Rotation is clockwise when viewed from drive end.

(2) Pressure Override Relief Valve:

Pressure setting ... 44000 ± 500 kPa (6381.76 ± 72.52 psi)

Installation torque ... 35 ± 3 N·m (25 ± 2 lb ft)

(3) Crossover Relief Valve (Forward) ... 47500 ± 750 kPa (6889.40 ± 108.78 psi)

Installation torque ... 100 ± 10 N·m (75 ± 5 lb ft)

(3) Crossover Relief Valve (Reverse) ... 47500 ± 750 kPa (6889.40 ± 108.78 psi)

Installation torque ... 100 ± 10 N·m (75 ± 5 lb ft)

(4) Charge pump ... 19 cc/rev (1.16 cu in/rev)

(6) Charge Relief Valve ... 2900 ± 100 kPa (420 ± 14 psi)

Installation torque ... 70 ± 5 N·m (50 ± 5 lb ft)

(7) Torque for two bolts ... 240 ± 40 N·m (180 ± 30 lb ft)

(8) Inch lever actuation is counter clockwise (location off) (dimension A) ... 35 degree
For test, use SAE 10W oil at 65°C (150°F).