Short Operating Manual for Vehicle Test Lane

Description of display Normal operation brake testing Normal operation brake test stand
Single wheel measuring Start test stand Measuring operation
Single wheel measuring Switching off criteria
• Left ON • Slip control
• Right ON • Sensoring rollers top
or
Axle measuring
Axle measuring • Manual termination by
• Automatic button STOP button
• Brake force after brake
testing longer than 6
seconds at the level of the
roller resistance
Saving arrow lamps flashes during
• Front axle roller resistance measuring
• Rear axle Ovality measuring
or or • Parking brake • Brake forces left and right
Repeated display larger than 500 N
• Front axle • The last three
• Rear axle measurements are saved
+ or or • Parking brake
A Main switch Printout via printer box
B Function keys Standard printer
C IR receiver • Olivetti DM 109 Entry of weight
D Brake force scale in [kN] and road grip in [%] • Seikosha SP-2400 • Overwriting of weight is
E Side slip measuring scale in [mm]
Four wheel measuring possible
F LED difference
• Change also possible after
G LED slip right Attention:
printout, as long as no
H LED slip left • pedal force sensor is necessary
new saving took place
I Pointer brake force left • only single wheel test is possible
J Pointer brake force right • Saving buttons for total
left wheel measuring Start test left side weight and axle weight
K Pictogram test devices,
Efficiency Z[%], axle weight, ovality Input buttons exist
• Single wheel measuring
L Brake force difference in F[%], ovality
• Both rollers starts with different
+ directions
Save left side + Display of current weight
• Front axle Saving button • LCD, right pointer
or total weight • 1,000 N = 1,000 kg
or • Rear axle
Start test right side
right wheel measuring
• Single wheel measuring
Saving button axle weight
• Both rollers starts with different
+ directions

Save right side or or


• Front axle Total deceleration
or
• Service brake
or • Rear axle
• Parking brake
+ or +

EDP 905 602 341 –00


Short Operating Manual for Vehicle Test Lane
Automatic operation brake testing Superautomatic operation brake testing Superautomatic brake test stand
Switch on automatic Switch on superautomatic Ovality measuring
• Remote control button • Remote control buttons • Brake forces left and right
• Press automatic button for • Press automatic button for larger than 1kN
or 1 second 3 seconds • Reduce brake force to
+ or roller resistance
Arrow lamps ON Arrow lamps ON • Maintain brake force larger
Red lamp ON than 500N constant
Important! • Measuring starts after 3
No vehicle on the roller set or seconds
on the suspension tester. Important! Repetition of the part order
Characteristics of the No vehicle on the roller. Z[%] F[%] • Peak value display
automatic finished
• Switching between Characteristics of the • 3 seconds waiting time
the test programs is superautomatic • Short brake impulse
automatic • Switching between the test Repeat measurement starts
• The start of the programs is automatic Caution
measuring is carried • The start of the measuring is Deactivated in the standard
out after a short carried out after a short configuration!
Arrow lamps ON warning phase warning phase
End automatic operation • Saving and printout is
automatic Driving support
Allocation of part order • Measurement ended
or numbers and test sequence • Motors remain switched
Automatic operation brake test stand • Part order 1 = front axle on
Ovality measuring Arrow lamps ON • Part order 2 = rear axle • Leave roller set
• Brake forces left and right • Part order P = parking brake
larger than 1000 N Red lamps ON
• Reduce brake force to IMPORTANT!
roller resistance The test sequence must be
• Maintain brake force maintained.
larger than 500N constant
• Measuring starts after 3 Automatic printout
seconds Standard printer
• Olivetti DM 109
• Seikosha SP-2400
LCD display
• Print message
• # Nos of printouts

End superautomatic

or

EDP 905 602 341 –00


Short Operating Manual Automatic / Superautomatic operation details
Brake test: complete sequence for front axle / standard procedure

1. 2. 3. 5. 6.
Arrows flashing
Brake test: complete sequence for front axle / standard procedure + ovality measurement

1. 2. 3. 4. 5.
Intelligent control via brake pedal – delete / repeat measurement without pressing button

1. 2. 3. 4. 5.->2.

Intelligent control via brake pedal – stop measurement without pressing button

1. 2. 3. 4. 5.