Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 10

GA mismatches layout

LEGENDS: GA matches layout

Unit Equipment Tag # Equipment Equipment Equipment


Orientation Description type

0300 0305-01 Vertical FURNACE


0300 0305-02 Vertical FURNACE
0300 0305-12 Vertical FURNACE
0300 0306-30 Vertical REACTOR
0300 0307-51 Horizontal EXCHANGER
0300 0307-61 Horizontal EXCHANGER
0300 0307-52A/B/C Horizontal EXCHANGER
0300 0307-62 Horizontal EXCHANGER
0300 0106-68 Vertical KO pot VESSEL
0300 0106-07 Vertical VESSEL
0300 0306-01 Vertical VESSEL
0300 0307-53A/B/C Horizontal EXCHANGER
0300 0307-53D Horizontal EXCHANGER
0300 0306-43 Horizontal VESSEL
0300 0306-44 Horizontal VESSEL
0300 0306-45 Horizontal VESSEL
0300 0306-42 Vertical VESSEL
0300 0306-52 Vertical VESSEL
0300 0106-59X Vertical VESSEL
0300 1C-21 Vertical VESSEL
0300 8106-44X Vertical VESSEL
0300 605.02 Horizontal incinerator
0300 0309-01/02 & 0109-01 compressor
4810-26 analyzer
0800 0806-01/02 vertical Vessel
0800 0806-03 vertical Vessel
0800 0827-01 vertical Vessel
0800 0806-13 horizontal Vessel
0800 0806-09 vertical Vessel
0800 0806-06 vertical Vessel
0800 0806-07 vertical Vessel
0800 0806-04 vertical Vessel
0800 0806-12 vertical Vessel
0800 0811-02 eductor not on ground
0800 0822-02
0800 0811-01 steam ejector not on ground
0800 0811-03 air mixer not on ground
frame filter drain
0800 0811-04 not on ground
pot
0800 0806-11 inline strainer not on ground
0306-53 KO Pot not on ground

PUMPS
0300 6308-02 Vertical PUMP
0300 0308-17 Horizontal PUMP
0300 0308-14 Horizontal PUMP
0300 0308-01 Horizontal PUMP
0300 0308-02 Horizontal PUMP
0300 0308-05/06 Horizontal PUMP
0300 0308-07 Horizontal PUMP
0300 0308-03/04 Horizontal PUMP
0300 0308-15 Horizontal PUMP
0300 0108-36X/37X Horizontal PUMP
0300 0108-88X/89X Horizontal PUMP
0300 2608-20X/21X Horizontal PUMP
Diameter
(mm)
GA Available GA Drawing company GA Document
no. Matches with
Layout (9A9) GA
layout

Yes Heurtey London L2W 5000 4902.2 NO


Yes Heurtey London L2W 4400
Yes BORN INC. 2262 4400
YES Robert Jenkins & Co. Ltd PO-60328 2500 2381.25 NO
YES AF CRAIG L35-0307-10 800 1241.43 NO
YES Industrie Mechannice CJ 4095/0023 - 1218
YES AF CRAIG 33359 1000 1250.95 NO
YES Industrie Mechannice CJ 4095/0023 - 1110
YES Procon L35-2822-01 1000 1219.2
YES G.Mangiarotti Job 119/72 1300 1249
YES Staveleys 3783/1 2500 2762.25 NO
YES Industrie Mechannice - 900 1092 NO
YES Industrie Mechannice - 900 1092 NO
YES Staveleys 3781/1 2000 2228.85 NO
YES Whiteley Dwg no 7012 1100 1241.43 NO
YES Staveleys 3781/1 1700 1857.375 NO
YES Gapper Niel A/2634 1000 797 NO
YES Woodall Deckham F/03/03-2/022256 1000 797 NO
YES Payne 1877-E 610 610 YES
YES Glapwell 3377/1 4638 4636 YES
YES 600 584 NO
YES NO
YES
new
yes Neill & Son - 4000 4000 YES
yes Newbank - 800 889 NO
yes W. wild - 3000 3000 Yes
yes Pall Houston - 914 914.4 Yes
yes Fram Europe - 900 740 No
yes Beverley - 500 406 No
yes Newbank - 900 508 No
yes Hobal - 400 330 No
yes 600 597 No
yes 250 406 No
yes
yes 300 406 No
no 250

no 750

pic found
pic found

YES Sundstrand 4729-8 600 660 NO


YES Amoco M/48-2/001417 W 900 W 900 YES
YES David brown GF B34089 W 1200 W 1118 NO
YES Procon GA-B 340085 W 1200 W 1016 NO
YES Procon GA-B 340084 W 1200 W 1118 NO
YES Procon GA B110321-2 W 1000/800 W 889 NO
YES Procon - W 1100 W 1130.3 NO
YES Procon - W 1500 W 1550 NO
YES Procon - W 1500 W 1550 NO
YES Procon - W 1200 W 1143 NO
YES Ingersoll - W 1000 W 840 NO
YES Amoco W 1010 W 1010 YES
Length/Height
(mm)

Layout Matches with


Length Type GA
(9A9) layout

-
-

Head to Head 4100 4083.05 NO


Head to Head - 8282 -
Head to Head 8000 7889.88 NO
Head to Head - 8227

Head to Head 6200 6100 NO


Head to Head 6200 6115 NO
Tan to Tan 9000 9144 NO
Tan to Tan 3000 3048 NO
Tan to Tan 9000 9144 NO

NO

4052 3951.8 No
3500 1422 No

2000 2100 NO
4600 4693 NO
3500 4276.73
4100 4267.2 NO
2000 1651 NO
1500 1676.4 NO
3300/3322 3450 NO
3300 3450 NO
2400 2667 NO
1500 1900 NO
2040 2040 YES
Remarks

correct as per GA
correct as per GA
correct as per GA
coorect as per GA
use above exchanger in plot plan or advise.
placed above 0307-51 but layout dia doesn’t match. Should be placed instead of 0307-51 on layout.
correct as per GA
placed above 0307-52c but layout dia doesn’t match.
correct as per GA
correct as per GA
correct as per GA
correct as per GA
0307-53D should be placed on layout as it is 15 mm longer than 0307-53C
correct as per GA
correct as per GA
correct as per GA
correct as per GA
correct as per GA
corrected
correct as per GA
new but same as existing required therefore correct as per GA
Mismatch,please refer MOM for drawing.
Mismatch,please refer MOM for drawing.
vendor to advise
mismatched as per OD. Correct as per GA
correct as per GA
correct as per GA
correct as per GA
correct as per GA
correct as per GA
correct as per GA
correct as per GA
outer ring not match with GA
Please check, is it required to show in plot plan or not? For dimension, please refer 3D model
Package mismatches, Misaligned package 0806-08,0808-04/05
mismatc, correct as per GA. For dimension, please refer 3D model
GA not found For dimension, please refer 3D model

GA not found For dimension, please refer 3D model

Filter pot,to be decided whether to remove from layout.For dimension, please refer 3D model
For dimension, please refer 3D model

0308-05/06 are same but in layout,different dimensions.

0308-03/04 are same but in layout,different dimensions.


YES VESSEL Tan to Tan
NO EXCHANGER Head to Head
new PUMP
REACTOR
FURNACE
incinerator
analyzer
compressor
Tan to Tan Vertical
Head to Head Horizontal