CARRIER HI-WALL ALPHA (FP-42KCE, 9K to 18K)

LED Status
Operation Description
Lamp Timer Lamp

Flashes at 5Hz OFF Indoor Fan speed has been out of control for over 1 minute

Indoor air sensor or coil thermistor is open circuit or short


Flashes at 5Hz ON circuit

OFF Flashes at 5Hz Over current protection of the compressor occurs 4 times

ON Flashes at 5Hz EEROM error

CARRIER HI-WALL ALPHA (FP-42KCE, 24K)

LED Status Description


Operation indicator, time indicator,
fan indicator, auto indicator flicker at Four times current protection (PRCUR1) 5Hz
5Hz
Timer indicator flickers at 5Hz The room air sensor is open or short
Operation indicator flickers at 5Hz The evaporator coil sensor is open or short
Auto indicator flicker at 5Hz EEROM Communication error
Action to be taken

Replace fan motor

Replace air or coil sensor


Check the following:
1. Run capacitor; replace if defective.
2. Compressor; replace if defective
Replace PCB

Action to be taken
Check the following:
1. Run capacitor; replace if defective
2. Compressor; replace if defective
Replace air sensor
Replace coil sensor
Replace PCB
CARRIER HI-WALL EXPRESSION (FP-42EXP, any size/capacity)

Fault Code
Description Possible Causes
(no. of blinks)
The room air sensor not properly connected to the PCB
2 Room Air Thermistor board
The room air sensor is damaged
The indoor coil thermistor is not properly connected to
Indoor Coil the PCB board
3 Thermostat
The indoor coil thermistor is damaged
The system cycles on indoor coil thermistor
a. Icing due to blocked air filters or clogged evaporator
coil

b. Icing evaporator coil due to system undercharged

c. System restricted
d. System out of gas
CDU not functioning
Compressor Drive a. Magnetic contactor defective
5
Malfunction
b. PCB board defective
Compressor runs but condenser fan not functioning
a. Fan capacitor is defective
b. Fan motor is defective
Compressor hums
a. Run capacitor defective
b. Compressor defective
PCB board defective
Action to be taken

Be sure that the sensor is properly connected to the PCB board

Replace the air sensor

Be sure that the sensor is properly connected to the PCB board

Replace the coil sensor

Clean air filters/evaporator coil

Locate/fix leak and recharge system

Remove restriction, reprocess and recharge system


Locate/fix leak and recharge system

Replace Contactor
Replace PCB board
tioning
Replace Capacitor
Replace Fan Motor

Replace Capacitor
Replace Compressor
Replace PCB board
CARRIER HI-WALL ZEN (FP-42LUC, 9K to 24K)

LED STATUS
Operation Timer Defrosting Auto

ON ON ON ON

OFF ON OFF OFF

ON OFF OFF OFF

OFF OFF ON OFF

OFF OFF ON ON

OFF ON ON ON
OFF OFF OFF ON
Description

Over current protection of the compressor occurs 4


times

Indoor air temp sensor is open circuit or short


circuit

Temp sensor on indoor evap is open or short circuit

Temp sensor on outdoor cond is open or short


circuit
Outdoor units protect (outdoor temp sensor, phase
order etc.)
EEROM error
Indoor unit communication error
Action to be taken
Check the following:
1. Run capacitor; replace if defective.
2. Compressor; replace if defective.

Check connector, if defective replace air sensor

Check connector, if defective replace coil sensor

Check connector, if defective replace outdoor coil


sensor

Replace PCB
Check wiring
CONDURA HI-WALL (FP-42KCR)

Operation – Green; Timer – Orange; Auto-Red; Defrost-Yellow


CARRIER OPTIMA (FP-42CSH)

OPERATION LAMP
DISPLAY TIMER LAMP FAILURE
FLASH TIMES

E1 1 X EEPROM error

E2 2 X Zero crossing detection error

E3 3 X Indoor fan speed has been out of control.

Indoor room temperature sensor T1 open


E5 5 X circuit or short circuit

E6 6 X Evaporator coil temperature sensor T2 open


circuit or short circuit

EC 2 O Refrigerant leak detection error

Indoor unit and outdoor unit communication


E9 9 X error (only available on 22K)
Temporary Solution

SHUT OFF POWER SUPPLY & TURN ON AFTER


5 SECONDS

SHUT OFF POWER SUPPLY & TURN ON AFTER


5 SECONDS

SHUT OFF POWER SUPPLY & TURN ON AFTER


5 SECONDS

SHUT OFF POWER SUPPLY & TURN ON AFTER


5 SECONDS
CARRIER IPOWER Inverter (FP-42CIV)

Display LED STATUS Def Timer Auto Operation


E0 EEPROM parameter error O O O O

E1 Indoor / outdoor units


communication protection ☆ ☆ ☆ ☆

E2 Zero-crossing signal error O O ☆ ☆

E3 Indoor fan speed out of control O O ☆ ☆

E5 Open or short circuit of X O X


outdoor temperature sensor ☆

Open or short circuit of room


E6 or evaporator temperature O O O ☆
sensor
Outdoor fan speed out of
E7 control ☆ O ☆ ☆

P0 IBM malfunction or IGBT over- X X O


strong current protection ☆

Over voltage or too low voltage


P1 X O O ☆
protection

P2 Temperature protection of O X X
compressor top. ☆

P4 Inverter compressor drive error O X ☆ ☆


Temporary Solution
Shut off the power supply and turn on it 5s later

Turn off the power supply, after 1 minute, connect the


power supply , turn on the unit with remote controller

Turn off the power supply and turn on it again 5 seconds


later

Shut off the power supply and turn on it 5s later

Check the connections between the sensors and the PCB.


Are the connections good?

Check whether the connections between outdoor PCB


and IPM are good?

Is the power supply good?

Does compressor operate?

Is the connection of compressor good? Is the wiring


sequence right? The voltage range proper?
CONDURA HW INVERTER (FP-42KHV)
CARRIER XPOWER SILVER (FP-42CSD)

Operation
Display lamp flash Timer Lamp

E0 1 X

E1 2 X

E2 3 X

E3 4 X

E4 5 X

E5 6 X

EC 7 X

F1 2 O

F2 3 O

F3 4 O

F4 5 O

P0 1 ☆

P1 2 ☆

P2 3 ☆

P4 5 ☆
Failure

EEPROM error

Indoor and outdoor communication error

Zero crossing

Indoor fan speed has been out of control

Indoor room temperature sensor T1 open circuit or short circuit

Evaporator coil temperature sensor T2 open circuit or short circuit

Refrigerant leak detection error

Outdoor temperature sensorT4 open circuit or short circuit

Condenser coil temperature sensor T3 open circuit

Compressor discharge temperature sensorT5 open circuit or short circuit

Outdoor EEPROM parameter error

IPM malfunction or IGBT over-strong current

Over voltage or too low voltage protection

Temperature protection of compressor top

Inverter compressor drive error


CARRIER XPOWER2 HW (FP-42CVUR)
CARRIER XPOWER2 HW (FP-42CVUR, 10K)
CARRIER XPOWER2 HW (FP-42CVUR, 13K/16K)
CARRIER XPOWER2 HW (FP-42CVUR, 18K)