GENERAL NOTES: SPLIT TYPE AC EQUIPMENT SCHEDULE

1. WORK COVERED SHALL CONFORM TO THE SPECIFICATIONS, STANDARD CODES, DESIGNATION AREA OF SERVICE QTY TYPE
NOMINAL COOLING ELECTRICAL CHARACTERISTICS
REMARKS
CAPACITY WATTS VOLTS PH HZ
ORDINANCES ISSUED BY LOCAL AUTHORITIES AND REQUIREMENTS.
RE FCU-G-01/ACCU-GF-01
s

Bedroom 1 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr


F
2. AIR CONDITIONING UNIT CAPACITY AS INDICATED/SHOWN ON THE DRAWING ARE (SU RIG
CT ERA FCU-GF-02/ACCU-GF-02 Bedroom 2 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr
ACTUAL AIR CONDITIONER DUTIES SHALL BE BASED ON 24 C DB AND 17 C WB IO NT
N/L
IQ PIPE FCU-GF-03/ACCU-GF-03 Bedroom 3 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr
INDOOR AND 35 C DB AND 28 C WB OUTDOOR TEMPERATURE. UID S
LIN
E) FCU-GF-04/ACCU-GF-04 Bedroom 4 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr
3. INDOOR UNIT SHALL BE OF THREE SPEED FAN (LOW, MEDIUM AND HIGH) WITH FCU-GF-05/ACCU-GF-05 Lower Great Room 3.0 HP 3800 230 1 60 EER = 10.5 kJ/W-hr
2 WALL MOUNTED
ACTUAL AIR CONDITIONER DUTIES SHALL BE BASED ON 24 C DB AND 17 C WB
FCU-2F-01/ACCU-2F-01 Bedroom 1 1 WALL MOUNTED 1.5 HP 950 230 1 60 EER = 12.4 kJ/W-hr
INDOOR AND 35 C DB AND 28 C WB OUTDOOR TEMPERATURE.
FCU-2F-02/ACCU-2F-02 Bedroom 2 1 WALL MOUNTED 1.5 HP 950 230 1 60 EER = 12.4 kJ/W-hr
4. INDOOR UNIT NOISE LEVEL SHALL BE NO MORE THAN 3O DB (A) AT 40 DB (A) DI
S FCU-2F-03/ACCU-2F-03 Bedroom 3 1 WALL MOUNTED 3.0 HP 3800 230 1 60 EER = 10.5 kJ/W-hr
AIRCHA

s
HIGH FAN/COIL.
FL RGE FCU-2F-04/ACCU-2F-04 EER = 13.6kJ/W-hr
OW Dining Area 2 WALL MOUNTED 2.5 HP 2275 230 1 60
5. THE AIR CONDITIONING UNIT SHALL BE CAPABLE TO OPERATE IN NORMAL CON- FCU-2F-05/ACCU-2F-05 Kitchen 2 WALL MOUNTED 3.0 HP 3800 230 1 60 EER = 10.5 kJ/W-hr
DITION AT 40 C AMBIENT. ST
E FCU-2F-08/ACCU-2F-08 Great Room 2 WALL MOUNTED 3.0 HP 3800 230 1 60 EER = 10.5 kJ/W-hr
CH EL
AN
6. REFRIGERANT PIPING SHALL BE INSTALLED AND VAPOR SEAL IN ACCORDANCE NE FCU-3F-01/ACCU-3F-01 Bedroom 1 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr
L
WITH ITEM NO. 1 ABOVE. FCU-3F-02/ACCU-3F-02 Bedroom 2 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr

FCU-3F-03/ACCU-3F-03 Bedroom 3 1 WALL MOUNTED 4.0 HP 3450 230 1 60 EER = 10.0 kJ/W-hr
7. PIPE SLEEVING SHALL BE PROVIDED WHEREVER REFRIGERANT PIPES PASSED
THROUGH ROOF SLAB OR IN WALLS. FCU-3F-04/ACCU-3F-04 Bedroom 4 2 WALL MOUNTED 3.0 HP 3800 230 1 60 EER = 10.5 kJ/W-hr

8. ALL REFRIGERANT PIPE RUN SHALL BE PROVIDED WITH SUITABLE SUPPPORT TO


ENGINEER APPROVAL. NOTE: REFRIGERANT IS R410/R32. VERIFY PIPE LENGTH. ALL CONDENSATE SHALL BE CONNECTED TO THE NEAREST DRAIN POINT CONNECTION
AIR COOLED CONDENSING UNIT PLATFORM
9. ALL FAN COIL UNIT (INDOOR UNIT) SHALL BE PROVIDED WITH CONDENSATE
EXHAUST FAN EQUIPMENT SCHEDULE
DRAINAGE AS INDICATED OR SHOWN ON THE DRAWING TERMINATED EITHER
TO SOAK AWAY DRAIN PIT.
CALCULATED ELECTRICAL
10. BOTH INDOOR AND OUTDOOR UNIT COILS SHALL BE NONFERROUS CONSTRUCTION UNIT QUANTITY AREA SERVED AIR FLOW RATE CHARACTERISTICS
R E M A R K S
WITH ALUMINUM PLATE FINS MECHANICALLY BONDED TO SEAMLESS COPPER DESIGNATION

TUBES WITH ALL JOINTS BRAZED. LPS WATTS VOLT PHASE CYCLE
ANCHOR BOLTS
11. BOTH INDOOR AND OUTDOOR UNIT SHALL BE PROVIDED WITH LABEL FOR PRO- CEF-01 2 Laundry Room/Pantry 24 13 230 1 60 CEILING MOUNTED
PER IDENTIFICATION UPON MAINTENANCE.
FCU
12. CONTRACTOR SHALL COORDINATE ALL BUILDERS WORK REQUIREMENT BASED ON
DRAWINGS & MATERIAL SUBMITTAL APPROVAL AND ALLOW SUCH WORK UNDER
HIS CONTRACT.
13. ALL EQUIPMENTS SHOWN ON THE PLANS SHALL CONFORM TO THE SPECIFICA- INSULATED
TIONS. CONDENSATE
DRAIN LINE

FAN SWITCH
CONTROL DESCRIPTION :
& THERMOSTAT
SYMBOLS AND ABBREVIATIONS: 1. THERMOSTAT T SHALL HAVE
OFF-FAN-COOL CONTROL.
WALL 2. SWITCH TO FAN SHALL START
FCU FAN.
WALL MOUNTED FAN COIL UNIT
3. SWITCH TO COOL SHALL START
THE ACCU WITH FAN ON.
CONNECT TO
AIR COOLED CONDENSING UNIT NEAREST FLOOR DRAIN
4. THERMOSTAT SHALL CYCLE THE
ACCU TO MAINTAIN ROOM TEM-
PERATURE AT 24°C.
FCU
---
FAN COIL UNIT DESIGNATION FCU AND ACCU REFRIGERANT PIPING AND
FLOOR

ACCU ELECTRICAL WIRING SCHEMATIC DIAGRAM


--- AIR COOLED CONDENSING UNIT DESIGNATION
"ARMAFLEX" RUBBER INSULATION
WALL MOUNTED FCU MOUNTING DETAILS
WRAPPED W/ POLYETHELENE BLUE TAPE

CONCRETE REFRIGERANT
SUPPLY LINE INSULATION
WALL
LIQUID PIPE
RETURN LINE
REFRIGERANT
SUCTION LINE

PIPE
INSULATION

19mm THK
"ARMAFLEX" RUBBER
NOTE: INSULATION
WRAPPED W/
INSULATION SHOULD NOT BE CUT AND POLYETHELENE
POLYETHYLENE TAPE
WRAPPED TO THE PIPE BUT SHOULD BLUE TAPE
BE INSERTED TO AVOID EXPOSURE OF
PIPE.
REFRIGERANT
SUCTION PIPE

WALL MOUNTED FCU MOUNTING DETAILS FLAT BAR REFRIGERANT PIPING DETAIL

REF. PIPES ALONG WALL DETAIL